1
|
Kuczaj A, Skrzypek M, Hudzik B, Kaczmarski J, Pawlak S, Hrapkowicz T, Przybyłowski P. Fibrin clot permeability (Ks) in patients on left ventricular assist device. Sci Rep 2024; 14:20193. [PMID: 39214985 PMCID: PMC11364743 DOI: 10.1038/s41598-024-69665-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Accepted: 08/07/2024] [Indexed: 09/04/2024] Open
Abstract
Patients on left ventricular assist devices (LVAD) are prone to excessive hemostasis disturbances due to permanent contact of artificial pump surfaces with blood components. We aimed to investigate if fibrin clot permeability is altered in patients on long-term continuous-flow LVAD therapy and if the clot permeability is associated with clinical characteristics and adverse events. We investigated 85 end-stage heart failure patients (90.6% men, age 48.6-63.8 years) scheduled for continuous flow long-term LVAD support according to current clinical indications. The patients were assessed periodically: prior to LVAD implantation (T1), 3-6 months (T2) after LVAD implantation, 6-12 months after (T3) and then every 6 months. We tested the first three blood samples (T1-T3) and the last available blood sample (T4), but no longer than 5 years after LVAD implantation. We assessed hemostasis parameters (Activated Partial Thromboplastin Time (APTT) Prothrombin Time, Activated Partial Thromboplastin Time, Fibrinogen, D-dimer, Antithrombin, Thrombin Time, Factor VIII, and von Willebrand Factor, aspirin-induced platelet inhibition, adenosine-diphosphate test) changes during the study period. Fibrin Clot Permeability was evaluated using a pressure system and Permeability Coefficient (Ks) was calculated. We observed a decrease in fibrin clot permeability (Ks) between T1, T2, T3 and T4 time periods; P < 0.01 for each comparison. Fibrin clot permeability was negatively correlated with fibrinogen concentration: r = - 0.51, P < 0.001, factor VIII activity r = - 0.42, P < 0.001. There was no association of Ks with age, Left Ventricular Ejection Fraction (LVEF) and medications P > 0.001, however cumulative measurements in patients on aspirin showed shortening of Ks in this group P = 0.0123. Major adverse cardiac and cerebrovascular events (MACCE) occurred in 36.5% patients, bleeding events in 25.9%, Net Adverse Clinical Events (NACE) in 62.4%; 31.7% patients died, and 17.6% underwent transplantation. The transplantation was considered as the endpoint. Discrepancies in Ks were observed between patients with MACCE, bleeding, and NACE, and patients without adverse events. Ks showed a constant trend towards normalization (P < 0.01) only in patients without adverse events. Patients with advanced heart failure have disturbed clot structure. A trend towards normalization of the Ks values is associated with fewer thromboembolic and bleeding complications in this group of patients.
Collapse
Affiliation(s)
- Agnieszka Kuczaj
- Department of Cardiac, Vascular and Endovascular Surgery and Transplantology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 41-800 Zabrze, M. C. Skłodowskiej 9, 40-055, Katowice, Poland.
| | - Michał Skrzypek
- Department of Biostatistics, School of Public Health in Bytom, Medical University of Silesia, 40-055, Katowice, Poland
| | - Bartosz Hudzik
- Third Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 40-055, Katowice, Poland
- Department of Cardiovascular Disease Prevention in Bytom, School of Public Health in Bytom, Medical University of Silesia, 40-055, Katowice, Poland
| | - Jacek Kaczmarski
- Medical University of Silesia, 40-055, Katowice, Poland
- Hemostasis Laboratory, Silesian Center for Heart Diseases, 41-800, Zabrze, Poland
| | - Szymon Pawlak
- Department of Cardiac, Vascular and Endovascular Surgery and Transplantology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 41-800 Zabrze, M. C. Skłodowskiej 9, 40-055, Katowice, Poland
| | - Tomasz Hrapkowicz
- Department of Cardiac, Vascular and Endovascular Surgery and Transplantology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 41-800 Zabrze, M. C. Skłodowskiej 9, 40-055, Katowice, Poland
| | - Piotr Przybyłowski
- Department of Cardiac, Vascular and Endovascular Surgery and Transplantology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 41-800 Zabrze, M. C. Skłodowskiej 9, 40-055, Katowice, Poland
| |
Collapse
|
2
|
Undas A. Laboratory Testing for Fibrinogen Disorders: From Routine Investigations to Research Studies. Semin Thromb Hemost 2024. [PMID: 38889802 DOI: 10.1055/s-0044-1787725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/20/2024]
Abstract
Congenital and acquired fibrinogen disorders often have heterogeneous clinical phenotypes and are challenging from a laboratory perspective. Fibrinogen determination using the Clauss method remains the gold standard, while the reproducibility and significance of the thrombin time and the reptilase time are limited. Molecular testing for causative mutations in fibrinogen genes is now recommended to confirm the diagnosis of congenital fibrinogen disorders. Research assays are used to evaluate alterations to fibrin formation and properties of plasma and purified fibrinogen-derived clots, characterized by fiber thickness, the number of branches, and pore sizes. Fibrin clot permeability (permeation, porosity) using a hydrostatic pressure system represents the most commonly used method for evaluating fibrin network density. Reduced clot permeability, which denotes the reduced size of an average pore in the network, results in tighter fibrin networks, typically associated with impaired susceptibility to lysis, leading to a thrombotic tendency. Biophysical properties of fibrin clots are largely assessed using rheometry, with atomic force microscopy and nanorheology being increasingly used in disease states. Thromboelastography and thromboelastometry, a simple modification of rheometry, have been used, mainly in intensive care units, for more than 50 years. Given growing evidence for altered fibrin clot properties in diseases with elevated risk of venous and arterial thromboembolism and in some bleeding disorders, further work on standardization and validation of the assessment of fibrin clot characteristics is needed. This review summarizes the current methods used to evaluate fibrinogen abnormalities in both diagnostic and research laboratories.
Collapse
Affiliation(s)
- Anetta Undas
- Department of Thromboembolic Diseases, Institute of Cardiology, Jagiellonian University Medical College, and Center for Research and Medical Technology, St. John Paul II Hospital, Cracow, Poland
| |
Collapse
|
3
|
Landi E, Mugnaini M, Vatansever T, Fort A, Vignoli V, Giurranna E, Argento FR, Fini E, Emmi G, Fiorillo C, Becatti M. Advancing Thrombosis Research: A Novel Device for Measuring Clot Permeability. SENSORS (BASEL, SWITZERLAND) 2024; 24:3764. [PMID: 38931548 PMCID: PMC11207702 DOI: 10.3390/s24123764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 05/28/2024] [Accepted: 06/07/2024] [Indexed: 06/28/2024]
Abstract
Thromboembolism, a global leading cause of mortality, needs accurate risk assessment for effective prophylaxis and treatment. Current stratification methods fall short in predicting thrombotic events, emphasizing the need for a deeper understanding of clot properties. Fibrin clot permeability, a crucial parameter in hypercoagulable states, impacts clot structure and resistance to lysis. Current clot permeability measurement limitations propel the need for standardized methods. Prior findings underscore the importance of clot permeability in various thrombotic conditions but call for improvements and more precise, repeatable, and standardized methods. Addressing these challenges, our study presents an upgraded, portable, and cost-effective system for measuring blood clot permeability, which utilizes a pressure-based approach that adheres to Darcy's law. By enhancing precision and sensitivity in discerning clot characteristics, this innovation provides a valuable tool for assessing thrombotic risk and associated pathological conditions. In this paper, the authors present a device that is able to automatically perform the permeability measurements on plasma or fibrinogen in vitro-induced clots on specific holders (filters). The proposed device has been tailored to distinguish clot permeability, with high precision and sensitivity, between healthy subjects and high cardiovascular-risk patients. The precise measure of clot permeability represents an excellent indicator of thrombotic risk, thus allowing the clinician, also on the basis of other anamnestic and laboratory data, to attribute a risk score to the subject. The proposed instrument was characterized by performing permeability measurements in plasma and purified fibrinogen clots derived from 17 Behcet patients and 15 sex- and age-matched controls. As expected, our results clearly indicate a significant difference in plasma clot permeability in Behcet patients with respect to controls (0.0533 ± 0.0199 d vs. 0.0976 ± 0.0160 d, p < 0.001). This difference was confirmed in the patient's vs. control fibrin clots (0.0487 ± 0.0170 d vs. 0.1167 ± 0.0487 d, p < 0.001). In conclusion, our study demonstrates the feasibility, efficacy, portability, and cost-effectiveness of a novel device for measuring clot permeability, allowing healthcare providers to better stratify thrombotic risk and tailor interventions, thereby improving patient outcomes and reducing healthcare costs, which could significantly improve the management of thromboembolic diseases.
Collapse
Affiliation(s)
- Elia Landi
- Department of Information Engineering and Mathematics, University of Siena, 53100 Siena, Italy; (M.M.); (T.V.); (A.F.); (V.V.)
| | - Marco Mugnaini
- Department of Information Engineering and Mathematics, University of Siena, 53100 Siena, Italy; (M.M.); (T.V.); (A.F.); (V.V.)
| | - Tunahan Vatansever
- Department of Information Engineering and Mathematics, University of Siena, 53100 Siena, Italy; (M.M.); (T.V.); (A.F.); (V.V.)
| | - Ada Fort
- Department of Information Engineering and Mathematics, University of Siena, 53100 Siena, Italy; (M.M.); (T.V.); (A.F.); (V.V.)
| | - Valerio Vignoli
- Department of Information Engineering and Mathematics, University of Siena, 53100 Siena, Italy; (M.M.); (T.V.); (A.F.); (V.V.)
| | - Elvira Giurranna
- Department of Experimental and Clinical Biomedical Sciences “Mario Serio”, University of Firenze, 50121 Florence, Italy; (E.G.); (F.R.A.); (E.F.); (C.F.); (M.B.)
| | - Flavia Rita Argento
- Department of Experimental and Clinical Biomedical Sciences “Mario Serio”, University of Firenze, 50121 Florence, Italy; (E.G.); (F.R.A.); (E.F.); (C.F.); (M.B.)
| | - Eleonora Fini
- Department of Experimental and Clinical Biomedical Sciences “Mario Serio”, University of Firenze, 50121 Florence, Italy; (E.G.); (F.R.A.); (E.F.); (C.F.); (M.B.)
| | - Giacomo Emmi
- Department of Medical, Surgical and Health Sciences, University of Trieste, 34100 Trieste, Italy;
| | - Claudia Fiorillo
- Department of Experimental and Clinical Biomedical Sciences “Mario Serio”, University of Firenze, 50121 Florence, Italy; (E.G.); (F.R.A.); (E.F.); (C.F.); (M.B.)
| | - Matteo Becatti
- Department of Experimental and Clinical Biomedical Sciences “Mario Serio”, University of Firenze, 50121 Florence, Italy; (E.G.); (F.R.A.); (E.F.); (C.F.); (M.B.)
| |
Collapse
|
4
|
Ząbczyk M, Stachowicz A, Natorska J, Olszanecki R, Wiśniewski JR, Undas A. Plasma fibrin clot proteomics in healthy subjects: Relation to clot permeability and lysis time. J Proteomics 2019; 208:103487. [PMID: 31425886 DOI: 10.1016/j.jprot.2019.103487] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2019] [Revised: 08/02/2019] [Accepted: 08/10/2019] [Indexed: 01/04/2023]
Abstract
BACKGROUND Little is known about fibrin clot composition in relation to its structure and lysability. We investigated plasma clots protein composition and its associations with clot properties. METHODS We studied 20 healthy subjects aged 31-49 years in whom plasma fibrin clot permeability (Ks) and clot lysis time (CLT) were determined. A proteomic analysis of plasma fibrin clots was based on quantitative liquid chromatography-mass spectrometry. RESULTS Among 494 clot-bound proteins identified in all clots, the highest concentrations were for fibrinogen chains (about 64% of the clot mass) and fibronectin (13%). α2-antiplasmin (2.7%), factor XIIIA (1.2%), complement component C3 (1.2%), and histidine-rich glycoprotein (HRG, 0.61%) were present at relatively high concentrations. Proteins present in concentrations <0.5% included (pro)thrombin, plasminogen, apolipoproteins, or platelet factor 4 (PF4). Fibrinogen-α and -γ chains were associated with age, while body-mass index with clot-bound apolipoproteins (all p < .05). Ks correlated with fibrinogen-γ and PF4 amounts within plasma clots. CLT was associated with fibrinogen-α and -γ, PF4, and HRG (all p < .05). CONCLUSIONS This study is the first to show associations of two key measures of clot properties with protein content within plasma clots, suggesting that looser fibrin clots with enhanced lysability contain less fibrinogen-γ chain, platelet-derived PF4, and HRG. SIGNIFICANCE Our study for the first time suggests that more permeable fibrin clots with enhanced lysability contain less fibrinogen-γ chain, platelet-derived factor 4, and histidine-rich glycoprotein, which is related to accelerated clot lysis. The current findings might have functional consequences regarding clot structure, stability, and propagation of thrombin generation, and detailed proteomic analysis of clots in various disorders opens new perspective for coagulation and fibrin research.
Collapse
Affiliation(s)
- Michał Ząbczyk
- Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland; Krakow Center for Medical Research and Technology, John Paul II Hospital, Krakow, Poland
| | - Aneta Stachowicz
- Chair of Pharmacology, Jagiellonian University Medical College, Krakow, Poland; Department of Proteomics and Signal Transduction, Max Planck Institute of Biochemistry, Martinsried, Germany
| | - Joanna Natorska
- Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland; Krakow Center for Medical Research and Technology, John Paul II Hospital, Krakow, Poland
| | - Rafał Olszanecki
- Chair of Pharmacology, Jagiellonian University Medical College, Krakow, Poland
| | - Jacek R Wiśniewski
- Department of Proteomics and Signal Transduction, Max Planck Institute of Biochemistry, Martinsried, Germany
| | - Anetta Undas
- Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland; Krakow Center for Medical Research and Technology, John Paul II Hospital, Krakow, Poland.
| |
Collapse
|
5
|
Celińska-Löwenhoff M, Zabczyk M, Iwaniec T, Plens K, Musiał J, Undas A. Reduced plasma fibrin clot permeability is associated with recurrent thromboembolic events in patients with antiphospholipid syndrome. Rheumatology (Oxford) 2018; 57:1340-1349. [DOI: 10.1093/rheumatology/key089] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/30/2023] Open
Affiliation(s)
| | - Michal Zabczyk
- Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland
| | - Teresa Iwaniec
- Department of Medicine, Jagiellonian University Medical College, Krakow, Poland
| | - Krzysztof Plens
- Data Analysis Center, Krakow Cardiovascular Research Institute, Krakow, Poland
| | - Jacek Musiał
- Department of Medicine, Jagiellonian University Medical College, Krakow, Poland
| | - Anetta Undas
- Department of Medicine, Jagiellonian University Medical College, Krakow, Poland
- Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland
- John Paul II Hospital, Center for Research and Medical Technologies, Krakow, Poland
| |
Collapse
|
6
|
Drabik L, Wołkow P, Undas A. Fibrin Clot Permeability as a Predictor of Stroke and Bleeding in Anticoagulated Patients With Atrial Fibrillation. Stroke 2017; 48:2716-2722. [PMID: 28904234 DOI: 10.1161/strokeaha.117.018143] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2017] [Revised: 08/12/2017] [Accepted: 08/15/2017] [Indexed: 01/24/2023]
Abstract
BACKGROUND AND PURPOSE Formation of denser fiber networks has been reported in atrial fibrillation and ischemic stroke. In this longitudinal cohort study, we evaluated whether fibrin clot density may predict thromboembolic and bleeding risk in patients with atrial fibrillation on vitamin K antagonists. METHODS In 236 patients with atrial fibrillation receiving vitamin K antagonists treatment, we measured ex vivo plasma clot permeability (Ks), a measure of the pore size in fibrin networks. RESULTS During a median follow-up of 4.3 (interquartile range, 3.7-4.8) years, annual rates of ischemic stroke or transient ischemic attack and major bleeds were 2.96% and 3.45%, respectively. In multivariate Cox regression analysis, patients with lower Ks (<6.8 cm2×10-9, median) had increased risk of ischemic stroke or transient ischemic attack (hazard ratio [HR], 6.55; 95% confidence interval [CI], 2.17-19.82) and major bleeds (HR, 10.65; 95% CI, 3.52-32.22). Patients with elevated Ks (≥6.8 cm2×10-9) had an increased rate of minor bleeding compared with the remainder (11.63% per year versus 3.55% per year; P<0.0001). The independent predictors of stroke or transient ischemic attack were low Ks (<6.8 cm2×10-9; HR, 7.24; 95% CI, 2.53-20.76), age (HR, 1.05; 95% CI, 1.01-1.10), and treatment with angiotensin-converting enzyme inhibitors (HR, 2.27; 95% CI, 1.08-4.77). Major bleeds were predicted by low Ks (<6.8 cm2×10-9; HR, 8.48; 95% CI, 2.99-24.1) and HAS-BLED score ≥3 (HR, 2.22; 95% CI, 1.12-4.38). CONCLUSIONS This study is the first to show that unfavorable fibrin properties reflected by formation of denser fibrin networks determine, in part, the efficacy and safety of anticoagulation with vitamin K antagonists in patients with atrial fibrillation.
Collapse
Affiliation(s)
- Leszek Drabik
- From the John Paul II Hospital, Krakow, Poland (L.D., A.U.), Centre for Medical Genomics-OMICRON (P.W.), Department of Pharmacology (L.D., P.W.) and Institute of Cardiology (A.U), Jagiellonian University Medical College, Krakow, Poland
| | - Paweł Wołkow
- From the John Paul II Hospital, Krakow, Poland (L.D., A.U.), Centre for Medical Genomics-OMICRON (P.W.), Department of Pharmacology (L.D., P.W.) and Institute of Cardiology (A.U), Jagiellonian University Medical College, Krakow, Poland
| | - Anetta Undas
- From the John Paul II Hospital, Krakow, Poland (L.D., A.U.), Centre for Medical Genomics-OMICRON (P.W.), Department of Pharmacology (L.D., P.W.) and Institute of Cardiology (A.U), Jagiellonian University Medical College, Krakow, Poland.
| |
Collapse
|
7
|
Gue YX, Gorog DA. Importance of Endogenous Fibrinolysis in Platelet Thrombus Formation. Int J Mol Sci 2017; 18:E1850. [PMID: 28841147 PMCID: PMC5618499 DOI: 10.3390/ijms18091850] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Revised: 08/21/2017] [Accepted: 08/21/2017] [Indexed: 12/13/2022] Open
Abstract
The processes of thrombosis and coagulation are finely regulated by endogenous fibrinolysis maintaining healthy equilibrium. When the balance is altered in favour of platelet activation and/or coagulation, or if endogenous fibrinolysis becomes less efficient, pathological thrombosis can occur. Arterial thrombosis remains a major cause of morbidity and mortality in the world despite advances in medical therapies. The role endogenous fibrinolysis in the pathogenesis of arterial thrombosis has gained increasing attention in recent years as it presents novel ways to prevent and treat existing diseases. In this review article, we discuss the role of endogenous fibrinolysis in platelet thrombus formation, methods of measurement of fibrinolytic activity, its role in predicting cardiovascular diseases and clinical outcomes and future directions.
Collapse
Affiliation(s)
- Ying X Gue
- Department of Cardiology, East and North Hertfordshire NHS Trust, Hertfordshire SG1 4AB, UK.
| | - Diana A Gorog
- Department of Cardiology, East and North Hertfordshire NHS Trust, Hertfordshire SG1 4AB, UK.
- Department of Postgraduate Medicine, University of Hertfordshire, Hertfordshire AL10 9AB, UK.
- National Heart & Lung Institute, Imperial College, London SW3 6LY, UK.
| |
Collapse
|