1
|
Georgieva-Tsaneva G, Gospodinova E, Cheshmedzhiev K. Cardiodiagnostics Based on Photoplethysmographic Signals. Diagnostics (Basel) 2022; 12:diagnostics12020412. [PMID: 35204503 PMCID: PMC8871237 DOI: 10.3390/diagnostics12020412] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 02/02/2022] [Accepted: 02/03/2022] [Indexed: 11/16/2022] Open
Abstract
The article presents a methodology to support the process of correct cardiodiagnostics based on cardio signals recorded with modern optical photoplethysmographic (PPG) sensor devices. An algorithm for preprocessing registered PPG signals and the formation of a time series for the analysis of heart rate variability is presented, which is an important information indicator in the diagnosis of cardiovascular diseases. In order to validate the proposed algorithm, an experimental scheme for synchronous recordings of PPG and electrocardiographic (ECG) signals and the study of the accuracy of the registered signals was created. The obtained results show high accuracy of the studied signals in terms of the following parameters: number of QRS complexes/pulse waves and mean RR intervals/PP intervals and the finding that the proposed algorithm is suitable for preprocessing PPG signals, as well as the possibility of interchangeable use of PPG and ECG. The results of the mathematical analysis of heart rate variability by applying linear methods (Time-Domain and Frequency-Domain) to two groups of people are presented: healthy controls and patients with cardiovascular disease (syncope). After determining the values of the parameters of the methods used, in order to distinguish healthy subjects from sick ones, statistical analysis was applied using t-test and Receiver Operating Characteristics (ROC) analysis. The obtained results show that the linear methods used are suitable for analysing the dynamics of PP interval series and for distinguishing healthy subjects from those with pathological diseases. The presented research and analyses can find applications in guaranteeing correctness and accuracy of conducting cardiodiagnostics in clinical practice.
Collapse
|
2
|
Photoplethysmography in Normal and Pathological Sleep. SENSORS 2021; 21:s21092928. [PMID: 33922042 PMCID: PMC8122413 DOI: 10.3390/s21092928] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 04/19/2021] [Accepted: 04/20/2021] [Indexed: 01/20/2023]
Abstract
This article presents an overview of the advancements that have been made in the use of photoplethysmography (PPG) for unobtrusive sleep studies. PPG is included in the quickly evolving and very popular landscape of wearables but has specific interesting properties, particularly the ability to capture the modulation of the autonomic nervous system during sleep. Recent advances have been made in PPG signal acquisition and processing, including coupling it with accelerometry in order to construct hypnograms in normal and pathologic sleep and also to detect sleep-disordered breathing (SDB). The limitations of PPG (e.g., oxymetry signal failure, motion artefacts, signal processing) are reviewed as well as technical solutions to overcome these issues. The potential medical applications of PPG are numerous, including home-based detection of SDB (for triage purposes), and long-term monitoring of insomnia, circadian rhythm sleep disorders (to assess treatment effects), and treated SDB (to ensure disease control). New contact sensor combinations to improve future wearables seem promising, particularly tools that allow for the assessment of brain activity. In this way, in-ear EEG combined with PPG and actigraphy could be an interesting focus for future research.
Collapse
|
3
|
Cros J, Dalmay F, Yonnet S, Charpentier M, Tran-Van-Ho J, Renaudeau F, Drouet A, Guilbaut P, Marin B, Nathan N. Continuous hemoglobin and plethysmography variability index monitoring can modify blood transfusion practice and is associated with lower mortality. J Clin Monit Comput 2019; 34:683-691. [PMID: 31376030 DOI: 10.1007/s10877-019-00367-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Accepted: 07/17/2019] [Indexed: 01/28/2023]
Abstract
To determine the effect of implementing an algorithm of fluid and blood administration based on continuous monitoring of hemoglobin (SpHb) and PVI (plethysmography variability index) on mortality and transfusion on a whole hospital scale. This single-center quality program compared transfusion at 48 h and mortality at 30 days and 90 days after surgery between two 11-month periods in 2013 and 2014 during which all the operating and recovery rooms and intensive care units were equipped with SpHb/PVI monitors. The entire team was trained to use monitors and the algorithm. Team members were free to decide whether or not to use devices. Each device was connected to an electronic wireless acquired database to anonymously acquire parameters on-line and identify patients who received the monitoring. All data were available from electronic files. Patients were divided in three groups; 2013 (G1, n = 9285), 2014 without (G2, n = 5856) and with (G3, n = 3575) goal-directed therapy. The influence of age, ASA class, severity and urgency of surgery and use of algorithm on mortality and blood use were analyzed with cox-proportional hazard models. Because in 2015, SpHb/PVI monitors were no longer available, we assessed post-study mortality observed in 2015 to measure the impact of team training to adjust vascular filling on a patient to patient basis. During non-cardiac surgery, blood was more often transfused during surgery in G3 patients as compared to G2 (66.6% vs. 50.7%, p < 0.001) but with fewer blood units per patient. After adjustment, survival analysis showed a lower risk of transfusion at 48 h in G3 [OR 0.79 (0.68-0.93), p = 0.004] but not in G2 [OR 0.90 (0.78-1.04) p = 0.17] as compared to G1. When adjusting to the severity of surgery as covariable, there was 0.5 and 0.7% differences of mortality at day 30 and 90 whether patients had goal directed therapy (GDT). After high risk surgery, the mortality at day 30 is reduced by 4% when using GDT, and 1% after intermediate risk surgery. There was no difference for low risk surgery. G3 Patients had a lower risk of death at 30 days post-surgery [OR 0.67 (0.49-0.92) p = 0.01] but not G2 patients [OR 1.01, (0.78-1.29), p = 0.96]. In 2015, mortality at 30 days and 90 days increased again to similar levels as those of 2013, respectively 2.18 and 3.09%. Monitoring SpHb and PVI integrated in a vascular filling algorithm is associated with earlier transfusion and reduced 30 and 90-day mortality on a whole hospital scale.
Collapse
Affiliation(s)
- Jérôme Cros
- Département d'Anesthésie Réanimation, CHU Dupuytren, 2 Avenue Martin Luther King, 87042, Limoges, France. .,Anesthésie Réanimation, Hôpital Mère-Enfant, Ave Docteur Larrey, 87042, Limoges, France. .,Département d'Anesthésie-Réanimation, Hôpital de la Mère et de l'enfant, 8, Avenue Dominique Larrey, 87000, Limoges, France.
| | - François Dalmay
- INSERM, U1094, Neuroépidémiologie Tropicale, 87000, Limoges, France.,Univ. Limoges, UMR_S 1094, Neuroépidémiologie Tropicale, Institut d'Epidémiologie Neurologique et de Neurologie Tropicale, CNRS FR, 3503 GEIST, 87000, Limoges, France.,CEBIMER, CHU Limoges, 2 Avenue Martin Luther King, 87042, Limoges, France
| | - Sandra Yonnet
- SIME, CHU Limoges, and Faculté de Médecine, Limoges, France
| | - Matthieu Charpentier
- Département d'Anesthésie Réanimation, CHU Dupuytren, 2 Avenue Martin Luther King, 87042, Limoges, France
| | - Jessica Tran-Van-Ho
- Département d'Anesthésie Réanimation, CHU Dupuytren, 2 Avenue Martin Luther King, 87042, Limoges, France
| | - François Renaudeau
- Département d'Anesthésie Réanimation, CHU Dupuytren, 2 Avenue Martin Luther King, 87042, Limoges, France
| | - Anais Drouet
- Département d'Anesthésie Réanimation, CHU Dupuytren, 2 Avenue Martin Luther King, 87042, Limoges, France
| | - Pierre Guilbaut
- Département d'Anesthésie Réanimation, CHU Dupuytren, 2 Avenue Martin Luther King, 87042, Limoges, France
| | - Benoit Marin
- INSERM, U1094, Neuroépidémiologie Tropicale, 87000, Limoges, France.,Univ. Limoges, UMR_S 1094, Neuroépidémiologie Tropicale, Institut d'Epidémiologie Neurologique et de Neurologie Tropicale, CNRS FR, 3503 GEIST, 87000, Limoges, France.,CEBIMER, CHU Limoges, 2 Avenue Martin Luther King, 87042, Limoges, France
| | - Nathalie Nathan
- Département d'Anesthésie Réanimation, CHU Dupuytren, 2 Avenue Martin Luther King, 87042, Limoges, France. .,Anesthésie Réanimation, Hôpital Mère-Enfant, Ave Docteur Larrey, 87042, Limoges, France.
| |
Collapse
|
4
|
Tusman G, Acosta CM, Pulletz S, Böhm SH, Scandurra A, Arca JM, Madorno M, Sipmann FS. Photoplethysmographic characterization of vascular tone mediated changes in arterial pressure: an observational study. J Clin Monit Comput 2018; 33:815-824. [PMID: 30554338 DOI: 10.1007/s10877-018-0235-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2018] [Accepted: 12/11/2018] [Indexed: 03/14/2023]
Abstract
To determine whether a classification based on the contour of the photoplethysmography signal (PPGc) can detect changes in systolic arterial blood pressure (SAP) and vascular tone. Episodes of normotension (SAP 90-140 mmHg), hypertension (SAP > 140 mmHg) and hypotension (SAP < 90 mmHg) were analyzed in 15 cardiac surgery patients. SAP and two surrogates of the vascular tone, systemic vascular resistance (SVR) and vascular compliance (Cvasc = stroke volume/pulse pressure) were compared with PPGc. Changes in PPG amplitude (foot-to-peak distance) and dicrotic notch position were used to define 6 classes taking class III as a normal vascular tone with a notch placed between 20 and 50% of the PPG amplitude. Class I-to-II represented vasoconstriction with notch placed > 50% in a small PPG, while class IV-to-VI described vasodilation with a notch placed < 20% in a tall PPG wave. 190 datasets were analyzed including 61 episodes of hypertension [SAP = 159 (151-170) mmHg (median 1st-3rd quartiles)], 84 of normotension, SAP = 124 (113-131) mmHg and 45 of hypotension SAP = 85(80-87) mmHg. SAP were well correlated with SVR (r = 0.78, p < 0.0001) and Cvasc (r = 0.84, p < 0.0001). The PPG-based classification correlated well with SAP (r = - 0.90, p < 0.0001), SVR (r = - 0.72, p < 0.0001) and Cvasc (r = 0.82, p < 0.0001). The PPGc misclassified 7 out of the 190 episodes, presenting good accuracy (98.4% and 97.8%), sensitivity (100% and 94.9%) and specificity (97.9% and 99.2%) for detecting episodes of hypotension and hypertension, respectively. Changes in arterial pressure and vascular tone were closely related to the proposed classification based on PPG waveform.Clinical Trial Registration NTC02854852.
Collapse
Affiliation(s)
- Gerardo Tusman
- Department of Anesthesiology, Hospital Privado de Comunidad, 7600, Mar del Plata, Buenos Aires, Argentina.
| | - Cecilia M Acosta
- Department of Anesthesiology, Hospital Privado de Comunidad, 7600, Mar del Plata, Buenos Aires, Argentina
| | - Sven Pulletz
- Department of Anesthesiology and Intensive Care Medicine, Klinikum Osnabrueck, Osnabrueck, Germany
| | - Stephan H Böhm
- Department of Anesthesiology and Intensive Care Medicine, Rostock University Medical Center, Rostock, Germany
| | - Adriana Scandurra
- Bioengineering Laboratory, Electronic Department, School of Engineering, Mar del Plata University, Mar del Plata, Argentina
| | - Jorge Martinez Arca
- Bioengineering Laboratory, Electronic Department, School of Engineering, Mar del Plata University, Mar del Plata, Argentina
| | - Matías Madorno
- Instituto Tecnológico Buenos Aires (ITBA), Buenos Aires, Argentina
| | - Fernando Suarez Sipmann
- Hedenstierna Laboratory, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.,CIBERES, Madrid, Spain.,Department of Critical Care, Hospital Universitario de La Princesa, Madrid, Spain
| |
Collapse
|
5
|
Li C, Xu J, Han F, Walline J, Zheng L, Fu Y, Zhu H, Chai Y, Yu X. Identification of return of spontaneous circulation during cardiopulmonary resuscitation via pulse oximetry in a porcine animal cardiac arrest model. J Clin Monit Comput 2018; 33:843-851. [PMID: 30498975 DOI: 10.1007/s10877-018-0230-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2018] [Accepted: 11/26/2018] [Indexed: 10/27/2022]
Abstract
In this prospective study we investigated whether the pulse oximetry plethysmographic waveform (POP) could be used to identify return of spontaneous circulation (ROSC) during cardio-pulmonary resuscitation (CPR). Tweleve pigs (28 ± 2 kg) were randomly assigned to two groups: Group I (non-arrested with compressions) (n = 6); Group II (arrested with CPR and defibrillation) (n = 6). Hemodynamic parameters and POP were collected and analyzed. POP was analyzed using both a time domain method and a frequency domain method. In Group I, when compressions were carried out on subjects with a spontaneous circulation, a hybrid fluctuation or "envelope" phenomenon appeared in the time domain method and a "double" or "fusion" peak appeared in the frequency domain method. In Group II, after the period of ventricular fibrillation was induced, the POP waveform disappeared. With compressions, POP showed a regular compression wave. After defibrillation, ROSC, and continued compressions, a hybrid fluctuation or "envelope" phenomenon appeared in the time domain method and a "double" or "fusion" peak appeared in the frequency domain method, similar to Group I. Analysis of POP using the time and frequency domain methods could be used to identify ROSC during CPR.
Collapse
Affiliation(s)
- Chen Li
- Emergency Department, Tianjin Medical University General Hospital, Tianjin, China
| | - Jun Xu
- Emergency Department, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, No.1 Shuaifuyuan Wangfujing, Dongcheng District, Beijing, China.
| | - Fei Han
- Institute of Life Monitoring, Mindray Corporation, Shenzhen, China
| | - Joseph Walline
- Division of Emergency Medicine, Department of Surgery, Saint Louis University Hospital, Saint Louis, MO, USA
| | - Liangliang Zheng
- Emergency Department, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, No.1 Shuaifuyuan Wangfujing, Dongcheng District, Beijing, China
| | - Yangyang Fu
- Emergency Department, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, No.1 Shuaifuyuan Wangfujing, Dongcheng District, Beijing, China
| | - Huadong Zhu
- Emergency Department, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, No.1 Shuaifuyuan Wangfujing, Dongcheng District, Beijing, China
| | - Yanfen Chai
- Emergency Department, Tianjin Medical University General Hospital, Tianjin, China
| | - Xuezhong Yu
- Emergency Department, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, No.1 Shuaifuyuan Wangfujing, Dongcheng District, Beijing, China
| |
Collapse
|
6
|
Tomita K, Nakada TA, Oshima T, Oami T, Aizimu T, Oda S. Non-invasive monitoring using photoplethysmography technology. J Clin Monit Comput 2018; 33:637-645. [PMID: 30284687 DOI: 10.1007/s10877-018-0205-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2018] [Accepted: 09/26/2018] [Indexed: 12/17/2022]
Abstract
We evaluated the accuracy and precision of a novel non-invasive monitoring device in comparison with conventional monitoring methods used in intensive care units (ICU). The study device was developed to measure blood pressure, pulse rate, respiratory rate, and oxygen saturation, continuously with a single sensor using the photoplethysmographic technique. Patients who were monitored with arterial pressure lines in the ICU were enrolled. Systolic and diastolic blood pressure, pulse rate, respiratory rate, and arterial oxygen saturation were measured continuously for 30 min at 5-min intervals using the conventional methods and the study device. The primary outcome variable was blood pressure. Blood pressure measured by the study device highly correlated with the arterial pressure line values (correlation coefficients > 0.95). Percent errors for systolic, diastolic and mean blood pressures were 2.4% and 6.7% and 6.5%, respectively. Percent errors for pulse rate, respiratory rate and oxygen saturation were 3.4%, 5.6% and 1.4%, respectively. The non-invasive, continuous, multi-parameter monitoring device presented high level of agreement with the invasive arterial blood pressure monitoring, along with sufficient accuracy and precision in the measurements of pulse rate, respiratory rate, and oxygen saturation.
Collapse
Affiliation(s)
- Keisuke Tomita
- Department of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo, Chiba, 260-8677, Japan
| | - Taka-Aki Nakada
- Department of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo, Chiba, 260-8677, Japan.
| | - Taku Oshima
- Department of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo, Chiba, 260-8677, Japan
| | - Takehiko Oami
- Department of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo, Chiba, 260-8677, Japan
| | - Tuerxun Aizimu
- Center for Frontier Medical Engineering, Chiba University, 1-8-1 Inohana, Chuo, Chiba, 260-8677, Japan
| | - Shigeto Oda
- Department of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo, Chiba, 260-8677, Japan
| |
Collapse
|
7
|
The importance of sensor contacting force for predicting fluid responsiveness in children using respiratory variations in pulse oximetry plethysmographic waveform. J Clin Monit Comput 2018; 33:393-401. [DOI: 10.1007/s10877-018-0183-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2018] [Accepted: 07/10/2018] [Indexed: 12/14/2022]
|
8
|
Sun S, Peeters WH, Bezemer R, Long X, Paulussen I, Aarts RM, Noordergraaf GJ. Finger and forehead photoplethysmography-derived pulse-pressure variation and the benefits of baseline correction. J Clin Monit Comput 2018; 33:65-75. [PMID: 29644558 PMCID: PMC6314999 DOI: 10.1007/s10877-018-0140-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Accepted: 04/05/2018] [Indexed: 11/25/2022]
Abstract
To non-invasively predict fluid responsiveness, respiration-induced pulse amplitude variation (PAV) in the photoplethysmographic (PPG) signal has been proposed as an alternative to pulse pressure variation (PPV) in the arterial blood pressure (ABP) signal. However, it is still unclear how the performance of the PPG-derived PAV is site-dependent during surgery. The aim of this study is to compare finger- and forehead-PPG derived PAV in their ability to approach the value and trend of ABP-derived PPV. Furthermore, this study investigates four potential confounding factors, (1) baseline variation, (2) PPV, (3) ratio of respiration and heart rate, and (4) perfusion index, which might affect the agreement between PPV and PAV. In this work, ABP, finger PPG, and forehead PPG were continuously recorded in 29 patients undergoing major surgery in the operating room. A total of 91.2 h data were used for analysis, from which PAV and PPV were calculated and compared. We analyzed the impact of the four factors using a multiple linear regression (MLR) analysis. The results show that compared with the ABP-derived PPV, finger-derived PAV had an agreement of 3.2 ± 5.1%, whereas forehead-PAV had an agreement of 12.0 ± 9.1%. From the MLR analysis, we found that baseline variation was a factor significantly affecting the agreement between PPV and PAV. After correcting for respiration-induced baseline variation, the agreements for finger- and forehead-derived PAV were improved to reach an agreement of − 1.2 ± 3.8% and 3.3 ± 4.8%, respectively. To conclude, finger-derived PAV showed better agreement with ABP-derived PPV compared to forehead-derived PAV. Baseline variation was a factor that significantly affected the agreement between PPV and PAV. By correcting for the baseline variation, improved agreements were obtained for both the finger and forehead, and the difference between these two agreements was diminished. The tracking abilities for both finger- and forehead-derived PAV still warrant improvement for wide use in clinical practice. Overall, our results show that baseline-corrected finger- and forehead-derived PAV may provide a non-invasive alternative for PPV.
Collapse
Affiliation(s)
- Shaoxiong Sun
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
- Philips Research, Eindhoven, The Netherlands.
| | | | | | - Xi Long
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Philips Research, Eindhoven, The Netherlands
| | - Igor Paulussen
- Philips Research, Eindhoven, The Netherlands
- Elisabeth-Tweesteden Hospital, Tilburg, The Netherlands
| | - Ronald M Aarts
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Philips Research, Eindhoven, The Netherlands
| | - Gerrit J Noordergraaf
- Philips Research, Eindhoven, The Netherlands
- Elisabeth-Tweesteden Hospital, Tilburg, The Netherlands
| |
Collapse
|
9
|
Saugel B, Bendjelid K, Critchley LA, Rex S, Scheeren TWL. Journal of Clinical Monitoring and Computing 2016 end of year summary: cardiovascular and hemodynamic monitoring. J Clin Monit Comput 2017; 31:5-17. [PMID: 28064413 DOI: 10.1007/s10877-017-9976-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2016] [Accepted: 01/02/2017] [Indexed: 12/29/2022]
Abstract
The assessment and optimization of cardiovascular and hemodynamic variables is a mainstay of patient management in the care for critically ill patients in the intensive care unit (ICU) or the operating room (OR). It is, therefore, of outstanding importance to meticulously validate technologies for hemodynamic monitoring and to study their applicability in clinical practice and, finally, their impact on treatment decisions and on patient outcome. In this regard, the Journal of Clinical Monitoring and Computing (JCMC) is an ideal platform for publishing research in the field of cardiovascular and hemodynamic monitoring. In this review, we highlight papers published last year in the JCMC in order to summarize and discuss recent developments in this research area.
Collapse
Affiliation(s)
- Bernd Saugel
- Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
| | - Karim Bendjelid
- Department of Anesthesiology and Intensive Care, Geneva University Hospitals, Geneva, Switzerland
| | - Lester A Critchley
- Department of Anesthesia and Intensive Care, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Steffen Rex
- Department of Anesthesiology and Department of Cardiovascular Sciences, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Thomas W L Scheeren
- Department of Anesthesiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| |
Collapse
|
10
|
Bendjelid K, Rex S, Scheeren T, Saugel B. Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring. J Clin Monit Comput 2016; 30:129-39. [DOI: 10.1007/s10877-016-9838-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2016] [Accepted: 01/27/2016] [Indexed: 11/30/2022]
|
11
|
Abstract
Infants admitted to health-care centers with acute bronchiolitis are frequently monitored with a pulse oximeter, a noninvasive method commonly used for measuring oxygen saturation. The decision to hospitalize children with bronchiolitis has been largely influenced by pulse oximetry, despite its questionable diagnostic value in delineating the severity of the illness. Many health-care providers lack the appropriate clinical fundamentals and limitations of pulse oximetry. This deficiency in knowledge might have been linked to changes in the management of bronchiolitis. The aim of this paper is to provide the current evidence on the role of pulse oximetry in bronchiolitis. We discuss the history, fundamentals of operation, and limitations of the apparatus. A search of the Google Scholar, Embase, Medline, and PubMed databases was carried out for published articles covering the use of pulse oximetry in bronchiolitis.
Collapse
Affiliation(s)
- Mohamed A Hendaus
- Department of Pediatrics, General Pediatrics Division, Hamad Medical Corporation, Doha, Qatar ; Weill-Cornell Medical College, Doha, Qatar
| | - Fatima A Jomha
- School of Pharmacy, Lebanese International University, Khiara, Lebanon
| | - Ahmed H Alhammadi
- Department of Pediatrics, General Pediatrics Division, Hamad Medical Corporation, Doha, Qatar ; Weill-Cornell Medical College, Doha, Qatar
| |
Collapse
|
12
|
Year in review in journal of clinical monitoring and computing 2014: cardiovascular and hemodynamic monitoring. J Clin Monit Comput 2015; 29:203-7. [DOI: 10.1007/s10877-015-9675-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2015] [Accepted: 02/13/2015] [Indexed: 10/23/2022]
|
13
|
The pre-ejection period during the Muller manoeuvre: mismatch or misreading? J Clin Monit Comput 2014; 28:223-4. [DOI: 10.1007/s10877-013-9542-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
14
|
Bendjelid K. Hemodynamic monitoring development: helpful technology or expensive luxury? J Clin Monit Comput 2013; 26:337-9. [PMID: 22936361 DOI: 10.1007/s10877-012-9394-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
15
|
Giraud R, Siegenthaler N, Morel DR, Romand JA, Brochard L, Bendjelid K. Respiratory change in ECG-wave amplitude is a reliable parameter to estimate intravascular volume status. J Clin Monit Comput 2012; 27:107-11. [PMID: 23117586 DOI: 10.1007/s10877-012-9405-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2012] [Accepted: 10/12/2012] [Indexed: 11/30/2022]
Abstract
Electrocardiogram (ECG) is a standard type of monitoring in intensive care medicine. Several studies suggest that changes in ECG morphology may reflect changes in volume status. The "Brody effect", a theoretical analysis of left ventricular (LV) chamber size influence on QRS-wave amplitude, is the key element of this phenomenon. It is characterised by an increase in QRS-wave amplitude that is induced by an increase in ventricular preload. This study investigated the influence of changes in intravascular volume status on respiratory variations of QRS-wave amplitudes (ΔECG) compared with respiratory pulse pressure variations (ΔPP), considered as a reference standard. In 17 pigs, ECG and arterial pressure were recorded. QRS-wave amplitude was measured from the Biopac recording to ensure that in all animals ECG electrodes were always at the same location. Maximal QRS amplitude (ECGmax) and minimal QRS amplitude (ECGmin) were determined over one respiratory cycle. ΔECG was calculated as 100 × [(ECGmax - ECGmin)/(ECGmax + ECGmin)/2]. ΔECG and ΔPP were simultaneously recorded. Measurements were performed at different time points: during normovolemic conditions, after haemorrhage (25 mL/kg), and following re-transfusion (25 mL/kg) with constant tidal volume (10 mL/kg) and respiration rate (15 breath/min). At baseline, ΔPP and ΔECG were both <12 %. ΔPP were significantly correlated with ΔECG (r(2) = 0.89, p < 0.001). Volume loss induced by haemorrhage increased significantly ΔPP and ΔECG. Moreover, during this state, ΔPP were significantly correlated with ΔECG (r(2) = 0.86, p < 0.001). Re-transfusion significantly decreased ΔPP and ΔECG, and ΔPP were significantly correlated with ΔECG (r(2) = 0.90, p < 0.001). The observed correlations between ΔPP and ΔECG at each time point of the study suggest that ΔECG is a reliable parameter to estimate the changes in intravascular volume status and provide experimental confirmation of the "Brody effect."
Collapse
Affiliation(s)
- Raphaël Giraud
- Intensive Care Service, Geneva University Hospitals, 4 Rue Gabrielle Perret-Gentil, 1211, Geneva 14, Switzerland.
| | | | | | | | | | | |
Collapse
|
16
|
Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis. Intensive Care Med 2012; 38:1429-37. [DOI: 10.1007/s00134-012-2621-1] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2012] [Accepted: 05/29/2012] [Indexed: 10/28/2022]
|
17
|
Chan GSH, Middleton PM, Lovell NH. Photoplethysmographic variability analysis in critical care--current progress and future challenges. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2011:5507-10. [PMID: 22255585 DOI: 10.1109/iembs.2011.6091405] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The concept of early goal-directed therapy emphasizes the need for early diagnosis and intervention to achieve better therapeutic outcomes in critical care. There has been rapidly growing interest in the use of the photoplethysmogram (PPG), also known as the "pulse oximetry waveform", as a noninvasive diagnostic tool in this clinical setting. The peripheral PPG exhibits beat-to-beat variability driven by physiological mechanisms such as respiration and sympathetic vascular activity. This paper provides an overview of the current progress towards the application of PPG waveform variability (PPGV) in emergency and intensive care. Studies to date have demonstrated the potential value of PPGV for assessing a range of pathophysiological conditions including blood loss, sepsis and low systemic vascular resistance. Translation of research findings into clinical practice poses several future challenges, including the need for large scale validation studies with appropriate measurement systems, more robust solutions to signal quality issues (such as motion artifacts), and better physiological understanding of the information-rich PPGV.
Collapse
Affiliation(s)
- Gregory S H Chan
- School of Electrical Engineering and Telecommunications, University of New South Wales, Sydney, NSW 2052, Australia.
| | | | | |
Collapse
|
18
|
Moitra VK, Gabrielli A, Maccioli GA, O’Connor MF. Anesthesia advanced circulatory life support. Can J Anaesth 2012; 59:586-603. [PMID: 22528163 PMCID: PMC3345112 DOI: 10.1007/s12630-012-9699-3] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2011] [Accepted: 03/14/2012] [Indexed: 02/07/2023] Open
Abstract
PURPOSE The constellation of advanced cardiac life support (ACLS) events, such as gas embolism, local anesthetic overdose, and spinal bradycardia, in the perioperative setting differs from events in the pre-hospital arena. As a result, modification of traditional ACLS protocols allows for more specific etiology-based resuscitation. PRINCIPAL FINDINGS Perioperative arrests are both uncommon and heterogeneous and have not been described or studied to the same extent as cardiac arrest in the community. These crises are usually witnessed, frequently anticipated, and involve a rescuer physician with knowledge of the patient's comorbidities and coexisting anesthetic or surgically related pathophysiology. When the health care provider identifies the probable cause of arrest, the practitioner has the ability to initiate medical management rapidly. CONCLUSIONS Recommendations for management must be predicated on expert opinion and physiological understanding rather than on the standards currently being used in the generation of ACLS protocols in the community. Adapting ACLS algorithms and considering the differential diagnoses of these perioperative events may prevent cardiac arrest.
Collapse
Affiliation(s)
- Vivek K. Moitra
- Department of Anesthesiology, College of Physicians and Surgeons, Columbia University, New York, NY USA
| | - Andrea Gabrielli
- Anesthesia Department, University of Florida, Gainesville, FL USA
| | | | - Michael F. O’Connor
- Department of Anesthesia and Critical Care, University of Chicago, 5841 S Maryland Ave, MC 4028, Chicago, IL 60637 USA
| |
Collapse
|
19
|
Radhakrishnan M, Mohanvelu K, Veena S, Sripathy G, Umamaheswara Rao GS. Pulse-plethysmographic variables in hemodynamic assessment during mannitol infusion. J Clin Monit Comput 2012; 26:99-106. [PMID: 22318409 DOI: 10.1007/s10877-012-9339-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2011] [Accepted: 01/18/2012] [Indexed: 11/25/2022]
Abstract
Plethysmographic signal using pulse oximetry may be used to assess fluid status of patients during surgery as it resembles arterial pressure waveform. This will avoid placement of invasive arterial lines. This study was designed to find out whether intravascular volume changes induced by mannitol bolus in neurosurgical patients are detected by variations in arterial pressure and plethysmographic waveforms and also to assess the strength of correlation between different variables derived from these two waveforms. The time difference between the onset of arterial and plethysmographic waveforms as means of significant hemodynamic changes was also evaluated. Forty one adult ASA I and II neurosurgical patients requiring mannitol infusion were recruited. Arterial line and plethysmographic probe were placed in the same limb. Digitized waveforms were collected before, at the end, and 15, 30 and 60 min after mannitol infusion. Using MATLAB, the following parameters were collected for three consecutive respiratory cycles,-systolic pressure variation (SPV), pulse pressure variation (PPV), plethysmographic peak variation (Pl-PV), plethysmographic amplitude variation (Pl-AV) and blood pressure-plethysmographic time lag (BP-Pleth time lag). Changes in above parameters over the study period were studied using repeated measure analysis of variance. Correlation between the parameters was analysed. SPV and Pl-PV showed significant increase at 15, 30 and 60 min compared to end of mannitol infusion (P < 0.01 for SPV; P < 0.05 for Pl-PV). PPV and Pl-AV showed significant increase only at 30 min (P < 0.05). The correlation between ∆SPV-∆Pl-PV, ∆PPV-∆Pl-AV and ∆SPV-∆BP-Pleth time lag were significant (r = 0.3; P < 0.01). SPV and time lag had no significant interaction. Pl-PV correlates well with SPV following mannitol infusion and can be used as an alternative to SPV. (BP-Pleth) time-lag promises to be an important parameter in assessing the state of peripheral vascular resistance and deserves further investigation.
Collapse
Affiliation(s)
- M Radhakrishnan
- Department of Neuroanaesthesia, National Institute of Mental Health and Neuro Sciences, Bangalore, Karnataka, India
| | | | | | | | | |
Collapse
|
20
|
Abstract
The introduction of pulse oximetry in clinical practice has allowed for simple, noninvasive, and reasonably accurate estimation of arterial oxygen saturation. Pulse oximetry is routinely used in the emergency department, the pediatric ward, and in pediatric intensive and perioperative care. However, clinically relevant principles and inherent limitations of the method are not always well understood by health care professionals caring for children. The calculation of the percentage of arterial oxyhemoglobin is based on the distinct characteristics of light absorption in the red and infrared spectra by oxygenated versus deoxygenated hemoglobin and takes advantage of the variation in light absorption caused by the pulsatility of arterial blood. Computation of oxygen saturation is achieved with the use of calibration algorithms. Safe use of pulse oximetry requires knowledge of its limitations, which include motion artifacts, poor perfusion at the site of measurement, irregular rhythms, ambient light or electromagnetic interference, skin pigmentation, nail polish, calibration assumptions, probe positioning, time lag in detecting hypoxic events, venous pulsation, intravenous dyes, and presence of abnormal hemoglobin molecules. In this review we describe the physiologic principles and limitations of pulse oximetry, discuss normal values, and highlight its importance in common pediatric diseases, in which the principle mechanism of hypoxemia is ventilation/perfusion mismatch (eg, asthma exacerbation, acute bronchiolitis, pneumonia) versus hypoventilation (eg, laryngotracheitis, vocal cord dysfunction, foreign-body aspiration in the larynx or trachea). Additional technologic advancements in pulse oximetry and its incorporation into evidence-based clinical algorithms will improve the efficiency of the method in daily pediatric practice.
Collapse
Affiliation(s)
- Sotirios Fouzas
- Respiratory Unit, Department of Pediatrics, University Hospital of Patras, Rio, 265 04 Patras, Greece.
| | | | | |
Collapse
|
21
|
Fingertip photoplethysmographic waveform variability and systemic vascular resistance in intensive care unit patients. Med Biol Eng Comput 2011; 49:859-66. [PMID: 21340639 DOI: 10.1007/s11517-011-0749-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2010] [Accepted: 01/31/2011] [Indexed: 12/31/2022]
Abstract
Low frequency variability in the fingertip photoplethysmogram (PPG) waveform has been utilized for inferring sympathetic vascular control, but its relationship with a quantitative measure of vascular tone has not been established. In this study, we examined the association between fingertip PPG waveform variability (PPGV) and systemic vascular resistance (SVR) obtained from thermodilution cardiac output (CO) and intra-arterial pressure measurements in 48 post cardiac surgery intensive care unit patients. Among the hemodynamic measurements, both CO (P < 0.05) and SVR (P < 0.0001) had statistically significant relationships with the normalized low frequency power (LF(nu)) of PPGV. The LF(nu) of baseline PPGV had moderate but significant positive correlation with SVR (r = 0.54, P < 0.0001), and a value below 52.5 nu was able to identify SVR < 900 dyn s cm⁻⁵ with sensitivity of 59% and specificity of 95%. The results have provided quantitative evidence to confirm the link between fingertip PPGV and sympathetic vascular control. Suppression of LF vasomotor waves leading to dominance of respiration-related HF fluctuations in the fingertip circulation was a specific (though not sensitive) marker of systemic vasodilatation, which could be potentially utilized for the assessment of critical care patients.
Collapse
|
22
|
Peripheral photoplethysmography variability analysis of sepsis patients. Med Biol Eng Comput 2010; 49:337-47. [PMID: 21153887 DOI: 10.1007/s11517-010-0713-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2010] [Accepted: 10/27/2010] [Indexed: 01/20/2023]
Abstract
Sepsis is associated with impairment in autonomic regulatory function. This work investigates the application of heart rate and photoplethysmogram (PPG) waveform variability analysis in differentiating two categories of sepsis, namely systemic inflammatory response syndrome (SIRS) and severe sepsis. Electrocardiogram-derived heart period (RRi) and PPG waveforms, measured from fingertips (Fin-PPG) and earlobes (Ear-PPG), of Emergency Department sepsis patients (n = 28) with different disease severity, were analysed by spectral technique, and were compared to control subjects (n = 10) in supine and 80° head-up tilted positions. Analysis of covariance (ANCOVA) was applied to adjust for the confounding factor of age. Low-frequency (LF, 0.04-0.15 Hz), mid-frequency (MF, 0.09-0.15 Hz) and high-frequency (HF, 0.15-0.60 Hz) powers were computed. The normalised MF power in Ear-PPG (MFnu(Ear)) was significantly reduced in severe sepsis patients with hyperlactataemia (lactate > 2 mmol/l), compared to SIRS patients (P < 0.05). Moreover, in a group of normal controls, MFnu(Ear) was not altered by head-up tilting (P > 0.05), suggesting that there may be a link between 0.1 Hz ear blood flow oscillation and tissue metabolic changes in sepsis, in addition to autonomic factors. The study highlighted the value of PPG spectral analysis in the non-invasive assessment of peripheral vascular regulation in sepsis patients, with potential implications in monitoring the progression of sepsis.
Collapse
|
23
|
Chan GSH, Tang CHH, Middleton PM, Cave G, Harvey M, Savkin AV, Lovell NH. Augmented photoplethysmographic low frequency waves at the onset of endotoxic shock in rabbits. Physiol Meas 2010; 31:1605-21. [DOI: 10.1088/0967-3334/31/12/004] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
24
|
Nilsson L, Goscinski T, Lindenberger M, Länne T, Johansson A. Respiratory variations in the photoplethysmographic waveform: acute hypovolaemia during spontaneous breathing is not detected. Physiol Meas 2010; 31:953-62. [DOI: 10.1088/0967-3334/31/7/006] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
25
|
[Microcirculatory alterations in critically ill patients: pathophysiology, monitoring and treatments]. ACTA ACUST UNITED AC 2010; 29:135-44. [PMID: 20116198 DOI: 10.1016/j.annfar.2009.10.023] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2008] [Accepted: 10/28/2009] [Indexed: 01/18/2023]
Abstract
Microcirculation represents a complex system devoted to provide optimal tissue substrates and oxygen. Therefore, pathophysiological and technological knowledge developments tailored for capillary circulation analysis should generate major advances for critically ill patients' management. In the future, microcirculatory monitoring in several critical care situations will allow recognition of macro-microcirculatory decoupling, and, hopefully, it will promote the use of treatments aimed at preserving tissue oxygenation and substrate delivery.
Collapse
|
26
|
|
27
|
Dempsey EM, Barrington KJ. Evaluation and treatment of hypotension in the preterm infant. Clin Perinatol 2009; 36:75-85. [PMID: 19161866 DOI: 10.1016/j.clp.2008.09.003] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
A large proportion of very preterm infants receive treatment for hypotension. The definition of hypotension is unclear, and, currently, there is no evidence that treating it improves outcomes or, indeed, which treatment to choose among the available alternatives. Assessment of circulatory adequacy of the preterm infant requires a careful clinical assessment and may also require ancillary investigations. The most commonly used interventions, fluid boluses and dopamine, are problematic: fluid boluses are statistically associated with worse clinical outcomes and may not even increase blood pressure, whereas dopamine increases blood pressure mostly by causing vasoconstriction and may decrease perfusion. For neither intervention is there any reliable data showing clinical benefit. Prospective trials of intervention for hypotension and circulatory compromise are urgently required.
Collapse
Affiliation(s)
- E M Dempsey
- Department of Neonatology, Cork University Maternity Hospital, Cork, Ireland
| | | |
Collapse
|