1
|
Xie LF, Lin Y, Chen MF, Zhang GC. Complete Transthoracic Echocardiography for the Assessment and Guidance of Percutaneous Atrial Septal Defect Closure in Adults without Balloon Sizing: An Observed Study with a 10-Year Follow-Up. J Cardiovasc Dev Dis 2023; 10:321. [PMID: 37623334 PMCID: PMC10455240 DOI: 10.3390/jcdd10080321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 07/25/2023] [Accepted: 07/26/2023] [Indexed: 08/26/2023] Open
Abstract
OBJECTIVES This study aims to determine if complete transthoracic echocardiography (TTE)-guided percutaneous atrial septal defect (ASD) closure without balloon sizing could be safe and efficacious in adult patients. METHODS A total of 551 patients with ASDs were enrolled in this study, of which 438 patients underwent percutaneous ASD closure. Patients who received TTE-guided percutaneous ASD closure were classified into group T, and those who underwent a procedure that was guided by transesophageal echocardiography (TEE) were classified into group E. The clinical characteristics and the outcomes of the patients were analyzed. RESULTS The characteristics were comparable at baseline, except for the body mass index (BMI) (21.6 ± 5.3 vs. 23.8 ± 7.1, p < 0.001) between group T and group E. No significant difference was observed between the two groups regarding in-hospital outcomes, except for the duration of the procedure (29.8 ± 15.3 min vs. 41.5 ± 20.4 min), the length of stay in the hospital (2.1 ± 2.3 d vs. 2.9 ± 2.6 d), and hospital costs (USD 6233.3 ± 312.4 vs. USD 6673.7 ± 446.9). There were no significant differences in the incidences of long-term complications, cardiac chamber sizes, and tricuspid regurgitation severity between the patients in the two groups during the 10-year follow-up period. CONCLUSION TTE may be as safe and efficacious as TEE for the assessment and guidance of percutaneous ASD closure without balloon sizing in adult patients with lower BMIs who are commonly found in East Asia.
Collapse
Affiliation(s)
- Lin-Feng Xie
- Department of Cardiovascular Surgery, Fujian Medical University Union Hospital, Fuzhou 350000, China; (L.-F.X.); (Y.L.); (M.-F.C.)
- Key Laboratory of Cardio-Thoracic Surgery (Fujian Medical University), Fujian Province University, Fuzhou 350000, China
- Fujian Provincial Center for Cardiovascular Medicine, Fuzhou 350000, China
| | - Yong Lin
- Department of Cardiovascular Surgery, Fujian Medical University Union Hospital, Fuzhou 350000, China; (L.-F.X.); (Y.L.); (M.-F.C.)
- Key Laboratory of Cardio-Thoracic Surgery (Fujian Medical University), Fujian Province University, Fuzhou 350000, China
- Fujian Provincial Center for Cardiovascular Medicine, Fuzhou 350000, China
| | - Mei-Fang Chen
- Department of Cardiovascular Surgery, Fujian Medical University Union Hospital, Fuzhou 350000, China; (L.-F.X.); (Y.L.); (M.-F.C.)
- Fujian Provincial Center for Cardiovascular Medicine, Fuzhou 350000, China
| | - Gui-Can Zhang
- Department of Cardiovascular Surgery, Fujian Medical University Union Hospital, Fuzhou 350000, China; (L.-F.X.); (Y.L.); (M.-F.C.)
- Fujian Provincial Center for Cardiovascular Medicine, Fuzhou 350000, China
| |
Collapse
|
2
|
Chen XL, Huang WH, Zheng YH, Zhang GC. Comparison of the efficacy and safety of sedation protocols with the use of dexmedetomidine-remifentanil and propofol-remifentanil during percutaneous closure of atrial septal defects: a randomized clinical trial. J Cardiothorac Surg 2022; 17:100. [PMID: 35505367 PMCID: PMC9066928 DOI: 10.1186/s13019-022-01834-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Accepted: 04/17/2022] [Indexed: 11/10/2022] Open
Abstract
Background The study was aimed to compare the efficacy and safety of different sedation protocols of dexmedetomidine–remifentanil and propofol–remifentanil for percutaneous closure of atrial septal defects (ASD) under transthoracic echocardiography (TTE) guidance. Material and methods From March 2020 to January 2021, of 114 patients screened, 59 ASD patients scheduled for percutaneous closure under TTE guidance were randomly allocated into the dexmedetomidine–remifentanil (D–R) group (n = 29) and the propofol–remifentanil (P–R) group (n = 30). The incidence of hemodynamic and respiratory adverse events, arterial blood gas analysis, induction and recovery time, pain score, infusion rate of remifentanil, satisfaction of the surgeon and patient, additional sedatives were collected for analysis and comparison. Results The induction time was longer in the D–R group than that in the P–R group (17.66 ± 2.65 min vs 11.43 ± 1.48 min; difference, 6.22 min; 95% CI 5.10 to 7.35; P < 0.001). No differences were observed in the 2 groups in terms of the additional sedatives, infusion rate of remifentanil, pain score, recovery time (P > 0.05). There was no difference between the two groups regarding the incidence of cardiovascular adverse events (6 [20.7%] vs 4 [13.3%]; difference, 7.4%; 95% CI − 11.7 to 26.5%; P = 0.506). Respiratory adverse events occurred in 1 patient (3.4%) in the D–R group, and 8 patients (26.7%) in the P–R group (difference, 23.3%; 95% CI 6.2 to 40.5%; P = 0.026). The incidence of hypercapnia was significantly lower in the D–R group (4 [13.8%]) than in the P–R group (13 [43.3%]; difference, 29.5%; 95% CI 7.8 to 51.2%; P = 0.012). Conclusions Except for more rapid the induction time and higher the surgeon satisfaction score in the propofol–remifentanil protocol, the efficacy was similar between two sedation protocols. The hemodynamic stability was comparable, the dexmedetomidine–remifentanil protocol had superior airway security due to fewer hypercapnia and respiratory adverse events.
Collapse
Affiliation(s)
- Xiao-Lan Chen
- Department of Intensive Care Unit, the First Affiliate Hospital, Fujian Medical University, Fuzhou, 350004, Fujian Province, People's Republic of China
| | - Wen-Hui Huang
- Anesthesiology Research Institute, the First Affiliated Hospital, Fujian Medical University, Fuzhou, 350004, Fujian Province, People's Republic of China
| | - Yi-Han Zheng
- Department of Cardiovascular Surgery, Fujian Medical University Union Hospital, Fuzhou, 350001, Fujian Province, People's Republic of China
| | - Gui-Can Zhang
- Department of Cardiovascular Surgery, Fujian Medical University Union Hospital, Fuzhou, 350001, Fujian Province, People's Republic of China.
| |
Collapse
|
3
|
Prakoso R, Ariani R, Lilyasari O, Kurniawati Y, Siagian SN, Sakidjan I, Roebiono PS, Rahajoe AU, Lelya O, Sembiring AA, Harimurti GM. Percutaneous atrial septal defect closure using transesophageal echocardiography without fluoroscopy in a pregnant woman: a case report. MEDICAL JOURNAL OF INDONESIA 2020. [DOI: 10.13181/mji.cr.193161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
Abstract
Transcatheter closure is the treatment of choice for atrial septal defect (ASD); it has good efficacy and minimal complications. However, this approach in a pregnant woman is limited due to the risk of radiation exposure. A novel fluoroscopy-free technique has been introduced to reduce x-ray exposure. This case reported the experience of an ASD transcatheter closure in a pregnant woman without fluoroscopy guidance. To the best of our knowledge, this is the first successful fluoroscopy-free technique for transcatheter closure in Indonesia. The case is a 26-year-old primigravida at 26 weeks’ gestational age with secundum ASD and pulmonary hypertension. Transcatheter closure was successfully performed with a Cera ASD occluder (Lifetech Scientific Corporation) no. 28 mm guided by transesophageal echocardiography. During the procedure, transient supraventricular tachycardia was developed. There were no other major or minor periprocedural complications. ASD transcatheter closure in a pregnant woman without fluoroscopy is feasible, safe, and effective.
Collapse
|
4
|
Alkashkari W, Albugami S, Hijazi ZM. Current practice in atrial septal defect occlusion in children and adults. Expert Rev Cardiovasc Ther 2020; 18:315-329. [PMID: 32441165 DOI: 10.1080/14779072.2020.1767595] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
INTRODUCTION Atrial septal defect (ASD) is one of the most common congenital heart diseases (CHD) in children and adults. This group of malformations includes several types of atrial communications allowing shunting of blood between the systemic and the pulmonary circulations. Early diagnosis and treatment carries favorable outcomes. Patients diagnosed during adulthood often present with complications related to longstanding volume overload such as pulmonary artery hypertension (PAH), atrial dysrhythmias, and right (RV) and left (LV) ventricular dysfunction. AREA COVERED This article intended to review all aspects of ASD; anatomy, pathophysiology, clinical presentation, natural history, and indication for treatment. Also, we covered the transcatheter therapy in detail, including the procedural aspect, available devices, and outcomes. EXPERT OPINION There has been a remarkable improvement in the treatment strategy of ASD over the last few decades. Transcatheter closure of ASD is currently accepted as the treatment of choice in most patients with appropriately selected secundum ASDs. This review will focus on the most recent advances in diagnosis and treatment strategy of secundum ASD.
Collapse
Affiliation(s)
- Wail Alkashkari
- Department of Cardiology, King Faisal Cardiac Center, Ministry of National Guard Health Affairs , Jeddah, Saudi Arabia.,Department of Postgraduate, King Saud Bin Abdulaziz University for Health Science , Jeddah, Saudi Arabia.,Department of Medical Research, King Abdullah International Medical Research Center , Jeddah, Saudi Arabia
| | - Saad Albugami
- Department of Postgraduate, King Saud Bin Abdulaziz University for Health Science , Jeddah, Saudi Arabia
| | - Ziyad M Hijazi
- Sidra Heart Center, Sidra Medicine , Doha, Qatar.,Weill Cornell Medicine , New York, NY, USA
| |
Collapse
|
5
|
Qiu HF, Chen Q, Hong ZN, Chen LW, Huang XS. Transcatheter and intraoperative device closure and surgical repair for atrial septal defect. J Cardiothorac Surg 2019; 14:136. [PMID: 31324190 PMCID: PMC6642487 DOI: 10.1186/s13019-019-0957-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Accepted: 07/15/2019] [Indexed: 11/10/2022] Open
Abstract
Background Transcatheter and intraoperative device closure for atrial septal defect (ASD) are widely applied to reduce the incision size and the potential for injury during cardiopulmonary bypass (CPB) in conventional surgical repair. No studies had been conducted to compare the safety and efficiency of these three treatments. Methods From January 2018 to April 2018, 87 patients with an isolated ASD who had undergone transcatheter device closure (n = 45), intraoperative device closure (n = 22) and surgical repair (n = 20) were retrospectively reviewed and further analyzed to compare these three treatments. Results The successful closure rate was similar in the three groups. There was a significant difference in aortic cross-clamping time, CPB duration and operative time between the surgical group and the device groups. The length of intensive care unit stay, postoperative mechanical ventilation time and length of hospital stay were shorter in the two device groups than in the surgical group. The incision was the most extended in the surgical group. Regarding major adverse events, no significant differences were found among the three groups. Conclusions Transcatheter and intraoperative device closure and surgical repair for ASD are all safe and effective. Considering their respective disadvantages and advantages, the transcatheter approach may be the first choice for an isolated secundum ASD, the intraoperative approach may be the second choice, and surgical repair may be the last resort.
Collapse
Affiliation(s)
- Han-Fan Qiu
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Fuzhou, 350001, People's Republic of China
| | - Qiang Chen
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Fuzhou, 350001, People's Republic of China
| | - Zhi-Nuan Hong
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Fuzhou, 350001, People's Republic of China
| | - Liang-Wan Chen
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Fuzhou, 350001, People's Republic of China
| | - Xue-Shan Huang
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Fuzhou, 350001, People's Republic of China.
| |
Collapse
|
6
|
Transcatheter device closure of atrial septal defects guided completely by transthoracic echocardiography: A single cardiac center experience with 152 cases. Anatol J Cardiol 2019; 20:330-335. [PMID: 30504733 PMCID: PMC6287434 DOI: 10.14744/anatoljcardiol.2018.90502] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Objective: This study aimed to assess the safety and feasibility of transcatheter device closure of atrial septal defects (ASDs) guided completely by transthoracic echocardiography (TTE). Methods: A total of 152 patients underwent transcatheter device closure of ASDs guided completely by TTE in our center from September 2014 to June 2017. We used routine delivery sheaths during the procedure and then closed the ASDs by releasing a domestic occluder. Results: The closure was successful in 150 patients, and surgical repair was required in two patients. The size of the deployed occluder ranged from 10 mm to 38 mm (21.4±8.5 mm), and the procedure duration ranged from 30 to 90 min (38.2±21.4 min). No fatal complications were observed. Minor complications included transient arrhythmias (n=12) during the process of device deployment. The follow-up period was 3 months to 2 years, with no occluder dislodgment, residual fistula, or thrombus-related complications. In our comparative studies, no statistically significant differences were observed in success rates and complications. Conclusion: Transcatheter device closure of ASDs guided completely by TTE may be safe and effective and can be an alternative to traditional methods.
Collapse
|
7
|
Chen Q, Cao H, Zhang GC, Chen LW, Xu F. Successful totally transthoracic echocardiography guided transcatheter device closure of atrial septal defect in pregnant women. World J Clin Cases 2019; 7:734-741. [PMID: 30968038 PMCID: PMC6448076 DOI: 10.12998/wjcc.v7.i6.734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Revised: 02/14/2019] [Accepted: 02/18/2019] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Transcatheter device closure of atrial septal defect (ASD) guided by fluoroscopy and/or transesophageal echocardiography is a mature technology. Little study has focused on whether the technology can be guided totally by transthoracic echocardiography (TTE), even in pregnant women with ASD.
AIM To evaluate the safety and efficacy of totally TTE guided transcatheter device closure of ASD in pregnant women.
METHODS Six pregnant women (gestational age 20-26 wk) with ASD underwent transcatheter device closure totally guided by TTE at our cardiac center from January 2015 to August 2017. A routine transcatheter procedure without fluoroscopy or intubation and a domestic occluder were used in this study.
RESULTS All patients had successful closure with good clinical results, and the overall immediate complete closure rate was 100%. The size of the occluder deployed ranged from 20 to 32 mm (26.7 ± 4.3 mm), the procedure time ranged from 30 to 50 min (41.7 ± 7.5 min), and the length of hospital stay was 2-3 d (mean 2.2 ± 0.4 d). There were no serious cardiovascular related complications, and transient arrhythmias occurred in one patient during the procedure. During the follow-up period (3 mo to 2 years), no occluder dislodgement, residual fistulas, or thromboses occurred. All of the patients underwent vaginal delivery between 36 and 38 wk of gestation.
CONCLUSION Totally TTE guided transcatheter device closure of ASD in pregnant women may be safe and effective.
Collapse
Affiliation(s)
- Qiang Chen
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Fuzhou 350001, Fujian Province, China
| | - Hua Cao
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Fuzhou 350001, Fujian Province, China
| | - Gui-Can Zhang
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Fuzhou 350001, Fujian Province, China
| | - Liang-Wan Chen
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Fuzhou 350001, Fujian Province, China
| | - Fan Xu
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Fuzhou 350001, Fujian Province, China
| |
Collapse
|