1
|
Paetow H, Streckenbach F, Brandt-Wunderlich C, Schmidt W, Stiehm M, Langner S, Cantré D, Weber MA, Schmitz KP, Siewert S. Development of a bioresorbable self-expanding microstent for interventional applications - an innovative approach for stent-assisted coiling. ROFO-FORTSCHR RONTG 2024; 196:714-725. [PMID: 38092021 DOI: 10.1055/a-2211-2983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/26/2024]
Affiliation(s)
- Hagen Paetow
- Institute for Implant Technology and Biomaterials e.V., Rostock, Germany
| | - Felix Streckenbach
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany
| | | | - Wolfram Schmidt
- Institute for Biomedical Engineering, Rostock University Medical Center, Rostock, Germany
| | - Michael Stiehm
- Institute for Implant Technology and Biomaterials e.V., Rostock, Germany
| | - Sönke Langner
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany
| | - Daniel Cantré
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany
| | - Marc-André Weber
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany
| | - Klaus-Peter Schmitz
- Institute for Implant Technology and Biomaterials e.V., Rostock, Germany
- Institute for Biomedical Engineering, Rostock University Medical Center, Rostock, Germany
| | - Stefan Siewert
- Institute for Implant Technology and Biomaterials e.V., Rostock, Germany
| |
Collapse
|
2
|
Gonzalez SM, Iordanou J, Adams W, Tsiang J, Frazzetta J, Kim M, Rezaii E, Pecoraro N, Zsigray B, Simon JE, Zakaria J, Jusue-Torres I, Li D, Heiferman DM, Serrone JC. Effect of Stent Porosity, Platelet Function Test Usage, and Dual Antiplatelet Therapy Duration on Clinical and Radiographic Outcomes After Stenting for Cerebral Aneurysms: A Meta-Analysis. World Neurosurg 2023; 171:159-166.e13. [PMID: 36529432 DOI: 10.1016/j.wneu.2022.12.055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Revised: 12/09/2022] [Accepted: 12/10/2022] [Indexed: 12/23/2022]
Abstract
BACKGROUND The use of stents with various porosities for treating cerebral aneurysms requires dual antiplatelet therapy (DAPT) without clear guidelines on the utility of platelet function tests (PFTs) and the duration of DAPT. We sought to determine the effects of stent porosity, PFT usage, and DAPT duration on the radiographic and clinical outcomes after stenting of cerebral aneurysms. METHODS PubMed was searched on March 29, 2021 for studies of cerebral aneurysm stenting that had specified the stent type and DAPT duration. A random effects meta-analysis was used to measure the prevalence of nonprocedural thrombotic and hemorrhagic events, clinical outcomes, aneurysm occlusion, and in-stent stenosis stratified by stent porosity, PFT usage, and DAPT duration. RESULTS The review yielded 105 studies (89 retrospective and 16 prospective) with 117 stenting cohorts (50 high porosity, 17 intermediate porosity, and 50 low porosity). In the high-, intermediate-, and low-porosity stenting cohorts, PFT usage was 26.0%, 47.1%, and 62.0% and the mean DAPT duration was 3.51 ± 2.33, 3.97 ± 1.92, and 5.18 ± 2.27 months, respectively. The intermediate-porosity stents showed a reduced incidence of hemorrhagic events (π = 0.32%) compared with low-porosity stents (π = 1.36%; P = 0.01) and improved aneurysm occlusion (π = 6.18%) compared with high-porosity stents (π = 14.42%; P = 0.001) and low-porosity stents (π = 11.71%; P = 0.04). The prevalence of in-stent stenosis was lower for the intermediate-porosity (π = 0.57%) and high-porosity (π = 1.51%) stents than for the low-porosity stents (π = 3.30%; P < 0.05). PFT use had resulted in fewer poor clinical outcomes (π = 3.54%) compared with those without PFT use (π = 5.94%; P = 0.04). The DAPT duration had no effect on the outcomes. CONCLUSIONS In the present meta-analysis, which had selected for studies of cerebral aneurysm stenting that had reported the DAPT duration, intermediate-porosity stents and PFT use had resulted significantly improved outcomes. No effect of DAPT duration could be detected.
Collapse
Affiliation(s)
| | - Jordan Iordanou
- Department of Neurological Surgery, Loyola University Medical Center, Maywood, Illinois, USA
| | - William Adams
- Department of Public Health Sciences, Parkinson School of Health Sciences and Public Health, Loyola University Chicago, Illinois, USA
| | - John Tsiang
- Department of Neurological Surgery, Loyola University Medical Center, Maywood, Illinois, USA
| | - Joseph Frazzetta
- Department of Neurological Surgery, Loyola University Medical Center, Maywood, Illinois, USA
| | - Miri Kim
- Department of Neurological Surgery, Loyola University Medical Center, Maywood, Illinois, USA
| | - Elhaum Rezaii
- Stritch School of Medicine, Loyola University Chicago, Maywood, Illinois, USA
| | - Nathan Pecoraro
- Department of Neurological Surgery, Loyola University Medical Center, Maywood, Illinois, USA
| | - Brandon Zsigray
- Department of Neurological Surgery, Loyola University Medical Center, Maywood, Illinois, USA
| | - Joshua E Simon
- Department of Neurological Surgery, Loyola University Medical Center, Maywood, Illinois, USA
| | - Jehad Zakaria
- Department of Neurological Surgery, Loyola University Medical Center, Maywood, Illinois, USA
| | | | - Daphne Li
- Department of Neurological Surgery, Loyola University Medical Center, Maywood, Illinois, USA
| | - Daniel M Heiferman
- Department of Neurological Surgery, Edward-Elmhurst Health, Naperville, Illinois, USA
| | - Joseph C Serrone
- Department of Neurological Surgery, Loyola University Medical Center, Maywood, Illinois, USA; Department of Neurological Surgery, Edward Hines Jr Veterans Affairs Hospital, Hines, Illinois, USA.
| |
Collapse
|
3
|
Jin J, Guo G, Ren Y, Yang B, Wu Y, Wang S, Sun Y, Wang X, Wang Y, Zheng J. Risk Factors for Recurrence of Intracranial Aneurysm After Coil Embolization: A Meta-Analysis. Front Neurol 2022; 13:869880. [PMID: 35937054 PMCID: PMC9355382 DOI: 10.3389/fneur.2022.869880] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Accepted: 05/23/2022] [Indexed: 11/13/2022] Open
Abstract
Intracranial aneurysm is a severe cerebral disorder involving complicated risk factors and endovascular coiling is a common therapeutic selection for intracranial aneurysm. The recurrence is a clinical challenge in intracranial aneurysms after coil embolization. With this study, we provided a meta-analysis of the risk factors for the recurrence of intracranial aneurysm after coil embolization. Nine studies were included with a total of 1,270 studies that were retrieved from the database. The sample size of patients with intracranial aneurysms ranged from 241 to 3,530, and a total of 9,532 patients were included in the present meta-analysis. The intracranial aneurysms that occurred in middle cerebral artery (MCA) (OR = 1.09, 95% CI: 1.03–1.16, P = 0.0045) and posterior circulation (OR = 2.01, 95% CI: 1.55–2.60, P = 0.000) presented the significantly higher risk of recurrence after coil embolization. Meanwhile, intracranial aneurysms of size > 7 mm (OR = 5.38, 95%CI: 3.76–7.70, P = 0.000) had a significantly higher risk of recurrence after coil embolization. Moreover, ruptured aneurysm (OR = 2.86, 95% CI: 2.02–4.04, P = 0.000) and subarachnoid hemorrhage (SAH) (OR = 1.57, 95% CI: 1.20–2.06, P = 0.001) was positively correlated with the risk of recurrence after coil embolization. In conclusion, this meta-analysis identified the characteristics of intracranial aneurysms with MCA, posterior circulation, size > 7 mm, ruptured aneurysm, and SAH as the risk factors of recurrence after coil embolization for intracranial aneurysms.
Collapse
Affiliation(s)
- Ji Jin
- School of Public Health, Shanxi Medical University, Taiyuan, China
| | - Geng Guo
- Department of Neurosurgery, The First Hospital, Shanxi Medical University, Taiyuan, China
- *Correspondence: Geng Guo
| | - Yeqing Ren
- Department of Neurosurgery, The First Hospital, Shanxi Medical University, Taiyuan, China
| | - Biao Yang
- Department of Neurosurgery, The First Hospital, Shanxi Medical University, Taiyuan, China
| | - Yongqiang Wu
- Department of Neurosurgery, The First Hospital, Shanxi Medical University, Taiyuan, China
| | - Shule Wang
- Department of Neurosurgery, The First Hospital, Shanxi Medical University, Taiyuan, China
| | - Yanqi Sun
- Department of Neurosurgery, The First Hospital, Shanxi Medical University, Taiyuan, China
| | - Xiaogang Wang
- Department of Neurosurgery, The First Hospital, Shanxi Medical University, Taiyuan, China
| | - Yuxiao Wang
- School of Public Health, Shanxi Medical University, Taiyuan, China
| | - Jianzhong Zheng
- School of Public Health, Shanxi Medical University, Taiyuan, China
| |
Collapse
|