1
|
Wu M, Hu Y, Hang J, Peng X, Mao C, Ye X, Li A. Qualitative and Quantitative Contrast-Enhanced Ultrasound Combined with Conventional Ultrasound for Predicting the Malignancy of Soft Tissue Tumors. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:237-247. [PMID: 34782165 DOI: 10.1016/j.ultrasmedbio.2021.10.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Revised: 10/05/2021] [Accepted: 10/07/2021] [Indexed: 06/13/2023]
Abstract
This study was aimed at evaluating the performance of perfusion patterns and the quantitative parameters of contrast-enhanced ultrasound (CEUS) in the detection of soft tissue tumors (STTs) and establishing a US workflow for STTs to improve patient management. Conventional ultrasound (US) and CEUS data were retrospectively collected from 156 soft tissue masses. Six perfusion patterns (P1-P6) were applied for CEUS qualitative analysis. Multivariate logistic regression was used to evaluate the performance of conventional US and qualitative and quantitative CEUS in distinguishing benign and malignant STTs. The malignancy rates of P1-P6 in STTs were 0%, 50.0%, 9.1%, 33.3%, 73.4% and 61.0%, respectively. For "non-P1" STTs, the predictive model combining quantitative CEUS parameters with conventional US features, including margin (odds ratio [OR] = 4.490, p = 0.000), vascular density (OR = 2.307, p = 0.013), 50% wash-out intensity (OR = 1.904, p = 0.032) and 50% wash-out time (OR = 1.031, p = 0.019), performed favorably in predicting malignancy, with an accuracy of 81.0% and an area under the receiver operating characteristic curve of 0.868. Furthermore, a US workflow for the detection of STTs based on conventional US and CEUS was established. CEUS with qualitative and quantitative analyses could be an effective tool for STT diagnosis. The US workflow in this study may improve the management of STT patients.
Collapse
Affiliation(s)
- Mengjie Wu
- Department of Ultrasound, First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China
| | - Yu Hu
- Department of Ultrasound, First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China
| | - Jing Hang
- Department of Ultrasound, First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China
| | - Xiaojing Peng
- Department of Ultrasound, First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China
| | - Cuilian Mao
- Department of Ultrasound, First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China
| | - Xinhua Ye
- Department of Ultrasound, First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China
| | - Ao Li
- Department of Ultrasound, First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China.
| |
Collapse
|
2
|
Song Q, Tian X, Jiao Z, Yan L, Lan Y, Zhu Y, Luo Y. Value of Conventional Ultrasonography with Contrast-Enhanced Ultrasonography in the Differential Diagnosis of Partial Cystic Thyroid Nodules. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2494-2501. [PMID: 34119357 DOI: 10.1016/j.ultrasmedbio.2021.03.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 03/11/2021] [Accepted: 03/12/2021] [Indexed: 06/12/2023]
Abstract
The value of contrast-enhanced ultrasonography (CEUS) in the diagnosis of malignant partial cystic thyroid nodules (PCTNs) remains unclear. Thus, in the present study, the data of patients with pathologically proven PCTNs who underwent CEUS in the Chinese PLA General Hospital from January 2016 to February 2019 were retrospectively reviewed, and the imaging characteristics of benign and malignant PCTNs were compared. A total of 177 PCTNs were enrolled in this study, including 58 (32.7%) malignant nodules and 119 (67.2%) benign nodules. Six characteristics significantly differed between malignant PCTNs and benign PCTNs in univariate comparison: position of the solid portion (χ2 = 17.937, p < 0.001), microcalcifications (χ2 = 81.382, p < 0.001), boundaries (χ2 = 45.486, p < 0.001), echogenicity (χ2 = 11.152, p = 0.004), intensity of enhancement (χ2 = 40.656, p < 0.001) and uniformity of enhancement (χ2 = 19.933, p < 0.001). Among these, microcalcifications, boundaries, position of the solid portion, and uniformity of enhancement were independent risk factors in the multivariate comparison. A logistic regression model for predicting benign and malignant PCTNs was established with a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 89.0% (95% confidence interval [CI]: 0.788-0.961), 91.0% (95% CI: 0.830-0.946), 81.0% (95% CI: 0.715-0.881), 95.0% (95% CI: 0.892-0.974) and 90.0% (95% CI: 0.844-0.938), respectively. The area under the receiver operating characteristic curve was 0.967 (95% CI: 0.944-0.990), which was significantly higher than that of conventional ultrasound only (0.747, 95% CI: 0.663-0.831, Z = 2.090, p = 0.0366). CEUS can be used in the diagnosis of PCTNs, and the four characteristics of malignant PCTNs proven by our study were microcalcifications, unclear boundaries, eccentric distributions of the solid parts and heterogeneous enhancement.
Collapse
Affiliation(s)
- Qing Song
- Department of Ultrasound, First Medical Center, General Hospital of Chinese PLA, Haidian District, Beijing, China; Department of Ultrasound, Seventh Medical Center, General Hospital of Chinese PLA, Dongcheng District, Beijing, China
| | - Xiaoqi Tian
- Department of Ultrasound, First Medical Center, General Hospital of Chinese PLA, Haidian District, Beijing, China
| | - Ziyu Jiao
- Department of Ultrasound, First Medical Center, General Hospital of Chinese PLA, Haidian District, Beijing, China
| | - Lin Yan
- Department of Ultrasound, First Medical Center, General Hospital of Chinese PLA, Haidian District, Beijing, China
| | - Yu Lan
- Department of Ultrasound, First Medical Center, General Hospital of Chinese PLA, Haidian District, Beijing, China
| | - Yaqiong Zhu
- Department of Ultrasound, First Medical Center, General Hospital of Chinese PLA, Haidian District, Beijing, China
| | - Yukun Luo
- Department of Ultrasound, First Medical Center, General Hospital of Chinese PLA, Haidian District, Beijing, China.
| |
Collapse
|
3
|
Piskunowicz M, Back SJ, Darge K, Humphries PD, Jüngert J, Ključevšek D, Lorenz N, Mentzel HJ, Squires JH, Huang DY. Contrast-enhanced ultrasound of the small organs in children. Pediatr Radiol 2021; 51:2324-2339. [PMID: 33830288 PMCID: PMC8566395 DOI: 10.1007/s00247-021-05006-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 11/17/2020] [Accepted: 02/08/2021] [Indexed: 11/28/2022]
Abstract
In pediatric and adult populations, intravenous contrast-enhanced ultrasound (CEUS) remains off-label for imaging of organs other than the liver and heart. This limited scope inhibits potential benefits of the new modality from a more widespread utilization. Yet, CEUS is potentially useful for imaging small organs such as the thyroid gland, lymph nodes, testes, ovaries and uterus, with all having locations and vasculature favorable for this type of examination. In the adult population, the utility of CEUS has been demonstrated in a growing number of studies for the evaluation of these small organs. The aim of this article is to present a review of pediatric CEUS of the thyroid gland, lymph nodes, testes, ovaries and uterus as well as to draw from the adult literature indications for possible applications in children.
Collapse
Affiliation(s)
- Maciej Piskunowicz
- Department of Radiology, Medical University of Gdansk, M. Sklodowskiej-Curie 3a Street, 80-210, Gdansk, Poland.
| | - Susan J. Back
- grid.25879.310000 0004 1936 8972Department of Radiology, Children’s Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA USA
| | - Kassa Darge
- grid.25879.310000 0004 1936 8972Department of Radiology, Children’s Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA USA
| | - Paul D. Humphries
- grid.424537.30000 0004 5902 9895Department of Radiology, Great Ormond Street Hospital for Children NHS Trust, London, UK
| | - Jörg Jüngert
- grid.5330.50000 0001 2107 3311Department of Pediatrics, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
| | - Damjana Ključevšek
- grid.29524.380000 0004 0571 7705Department of Radiology, University Children’s Hospital Ljubljana, Ljubljana, Slovenia
| | - Norbert Lorenz
- grid.4488.00000 0001 2111 7257Children’s Hospital, Dresden Municipal Hospital, Teaching-Hospital of Technical University Dresden, Dresden, Germany
| | - Hans-Joachim Mentzel
- grid.275559.90000 0000 8517 6224Section of Pediatric Radiology, Institute of Diagnostic and Interventional Radiology, University Hospital, Jena, Germany
| | - Judy H. Squires
- grid.239553.b0000 0000 9753 0008Department of Radiology, University of Pittsburgh Medical Center, Children’s Hospital of Pittsburgh, Pittsburgh, PA USA
| | - Dean Y. Huang
- grid.46699.340000 0004 0391 9020Department of Radiology, King’s College Hospital, Denmark Hill, London, UK
| |
Collapse
|
4
|
Zhang J, Zhang X, Meng Y, Chen Y. Contrast-enhanced ultrasound for the differential diagnosis of thyroid nodules: An updated meta-analysis with comprehensive heterogeneity analysis. PLoS One 2020; 15:e0231775. [PMID: 32310968 PMCID: PMC7170259 DOI: 10.1371/journal.pone.0231775] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2019] [Accepted: 03/31/2020] [Indexed: 12/16/2022] Open
Abstract
The diagnostic accuracy of contrast-enhanced ultrasound (CEUS) for distinguishing malignant thyroid nodules from benign thyroid nodules remains controversial. This meta-analysis was performed to evaluate the overall diagnostic value of CEUS for the characterization of thyroid nodules. Relevant studies were identified by searching PubMed, Embase and the Cochrane Library until August 1th 2019 to assess the overall diagnostic accuracy of CEUS. 37 eligible studies were included in the present meta-analysis. The pooled sensitivity, specificity, positive likelihood rate, negative likelihood rate and diagnostic odds ratio of CEUS were 0.87, 0.83, 5.38, 0.17 and 38.94, respectively, with the AUC of 0.9263. Subgroup analysis showed the heterogeneity was greatly reduced in small nodules group (≤ 1 cm) (I2 = 0.0%), while heterogeneity was still observed in the group of variable sizes group (I2 = 69.5%). However, meta-regression analysis revealed that only diagnostic criterion was the major source of heterogeneity (p = 0.0259). The risk of publication bias was negligible (p = 0.35). CEUS exhibited high accuracy for the identification of thyroid nodules and might provide additional perfusion information for the current US imaging reporting systems.
Collapse
Affiliation(s)
- Juanjuan Zhang
- Department of Ultrasound, Huaihe Hospital of Henan University, Henan, China
| | - Xiuting Zhang
- Department of Ultrasound, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Yanna Meng
- Department of Ultrasound, Huaihe Hospital of Henan University, Henan, China
| | - Yinghong Chen
- Department of Ultrasound, Huaihe Hospital of Henan University, Henan, China
| |
Collapse
|