1
|
Zhang J, Shao J, Cao X, Zhang Y, Zheng L. Fitting-Shape-based Strategy for Topography-guided LASIK: A Prospective Study. J Refract Surg 2024; 40:e336-e343. [PMID: 38717081 DOI: 10.3928/1081597x-20240415-01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/19/2024]
Abstract
PURPOSE To assess and compare the visual acuity and refractive outcomes of topography-guided laser in situ keratomileusis (LASIK) based on the fitting-shape-based refractive compensated and Phorcides software strategies. METHODS Consecutive patients who underwent topography-guided LASIK were included in this study. Through double-masked simple randomization, patients were assigned to the Zhang & Zheng Auto-compensate Refraction (ZZ AR) group (the fitting-shape-based refractive compensated strategy using the ZZ AR calculator was used) or the Phorcides group (the topography analysis algorithm in Phorcides software [Phorcides LLC] was used). Only one eye per patient with binocular correction was randomly enrolled. The preoperative and postoperative visual acuities and refraction were analyzed at the 6-month follow-up visit. RESULTS The ZZ AR and Phorcides groups comprised 156 and 147 eyes, respectively. At the 6-month postoperative follow-up visit, the median (range) absolute residual cylindrical refraction was 0.35 (1.01) and 0.47 (1.63) diopters (D) for the ZZ AR and Phorcides groups, respectively (P < .001). The percentages of patients with residual cylindrical power within 0.25 D were 29.49% and 13.61% for the ZZ AR and Phorcides groups, respectively (P = .001). Based on the percentages of patients with residual cylindrical powers within 0.50 and 1.00 D, the ZZ AR group showed better outcomes (P = .02 and .01). The percentage of patients with visual acuity better than 20/16 was significantly higher for the ZZ AR group than for the Phorcides group (P = .03). CONCLUSIONS The fitting-shape-based refractive compensated strategy for topography-guided LASIK procedures can better optimize the visual acuity and astigmatic refraction than the Phorcides software strategy. [J Refract Surg. 2024;40(5):e336-e343.].
Collapse
|
2
|
Wang Y, Zheng J, Guo Z, Fang X. Efficacy and safety of small-incision corneal intrastromal lenticule implantation for hyperopia correction: a systematic review and meta-analysis. Front Med (Lausanne) 2024; 11:1320235. [PMID: 38435392 PMCID: PMC10904476 DOI: 10.3389/fmed.2024.1320235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Accepted: 02/06/2024] [Indexed: 03/05/2024] Open
Abstract
Purpose To assess the efficacy and safety of intrastromal lenticule implantation for the treatment of hyperopia. Methods A systematic search of PubMed, Web of Science, Embase, Cochrane Library, China National Knowledge Internet, and Wan Fang Database identified studies on small-incision intrastromal lenticule implantation for hyperopia correction until January 2023. The Joanna Briggs Institute (JBI) critical appraisal tool was used to assess the quality of the retrospective research, and the Methodological Index for Non-randomized Studies (MINORS) was used to assess the quality of the prospective research. This study included postoperative visual outcomes, corneal morphology, and biomechanical outcomes. Results A total of 456 articles were identified, of which 10 were included in the meta-analysis. Ten single-arm studies involving 190 eyes were included. A meta-analysis demonstrated that corneal intrastromal lenticule implantation treatment significantly improved hyperopia. Uncorrected distance visual acuity (UDVA) significantly improved compared to the preoperative value (p = 0.027), corrected distance visual acuity showed no difference compared to the preoperative value (p = 0.27), and 87% eyes have no loss of one or more lines in the Snellen lines of CDVA (p < 0.00001). There was a significant difference between the spherical equivalent refractive (SE) and preoperative examination (p < 0.00001), 52% of eyes had ±0.5 diopters (D) postoperative SE (p < 0.00001), and 74% eyes had ±1.0 D postoperative SE (p < 0.00001). The central corneal thickness (CCT) increased by 72.68 μm compared to that preoperatively (p < 0.00001), and corneal curvature increased by 4.18D (p < 0.00001). The Q-value decreased by 0.82 (p < 0.00001), and higher-order aberration (HOA) decreased by 0.66 (p < 0.00001). Conclusion Small-incision intrastromal lenticule implantation may be an effective solution for correcting hyperopia. The effect of improved vision is significant, but further exploration is needed for changes in corneal biomechanics and long-term safety.Systematic review registration: https://www.crd.york.ac.uk/PROSPERO/, identifier: CRD42023432343.
Collapse
Affiliation(s)
- Yue Wang
- Ophthalmology, Liaoning Aier Eye Hospital, Shenyang, China
| | - Jingjing Zheng
- Ophthalmology, Liaoning Aier Eye Hospital, Shenyang, China
| | - Zuofeng Guo
- Ophthalmology, Liaoning Aier Eye Hospital, Shenyang, China
| | - Xuejun Fang
- Ophthalmology, Liaoning Aier Eye Hospital, Shenyang, China
- AIER School of Ophthalmology, Central South University, Changsha, China
| |
Collapse
|
3
|
Zhang J, Shao J, Cao X, Zhang Y, Zheng L. Defocus Curve and Satisfaction of Patients with Presbyopia After LASIK Using the Differential Modulation of Binocular Longitudinal Spherical Aberration. Clin Ophthalmol 2023; 17:3531-3542. [PMID: 38026604 PMCID: PMC10676107 DOI: 10.2147/opth.s437324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Accepted: 11/16/2023] [Indexed: 12/01/2023] Open
Abstract
Purpose To investigate the visual acuity and satisfaction of patients after Zhang & Zheng's corneal laser-enhanced accommodation refraction Q (ZZ-CLEAR-Q) surgery utilizing differential modulation of binocular longitudinal spherical aberration and determine its clinical significance. Patients and Methods This prospective observational study enrolled a consecutive cohort of patients with presbyopia who underwent ZZ-CLEAR-Q surgery between December 2020 and January 2023. The study assessed visual acuity, distance-corrected defocus curve, satisfaction, Q factor, manifest spherical equivalent, and primary spherical aberration, among others, at 3 months postoperatively. Additionally, the study conducted a binocular comparison to analyze the clinical significance of setting the different longitudinal spherical aberrations. Results A total of 232 eyes of 116 patients were included. The binocular uncorrected distance visual acuity was 20/20 for all patients. At 3 months postoperatively, the binocular uncorrected near visual acuity was Jaeger 1 for 96% of the patients and Jaeger 2 for 100% of the patients. Furthermore, 93.1% of the patients expressed satisfaction. The monocular distance-corrected defocus curve revealed that the dominant eyes had significantly better visual acuity at 0 D (P<0.001), while the non-dominant eyes had significantly better visual acuity across various defocus levels except 0 and -0.50 D (All P<0.05). At 3 months, there were no significant differences between the expected and achieved manifest spherical equivalents, corneal Q factor values, and ocular primary spherical aberration values of both groups. Conclusion Patients with presbyopia who underwent ZZ-CLEAR-Q surgery were likely to achieve normal uncorrected visual acuity and be satisfied. The increased depth of field has clinical significance for assisting near vision.
Collapse
Affiliation(s)
- Jun Zhang
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| | - Jie Shao
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| | - Xinfang Cao
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| | - Yonggang Zhang
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| | - Li Zheng
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| |
Collapse
|
4
|
Corneal Higher-Order Aberrations Measurements: Precision of SD-OCT/Placido Topography and Comparison with a Scheimpflug/Placido Topography in Eyes After Small-Incision Lenticule Extraction. Ophthalmol Ther 2023; 12:1595-1610. [PMID: 36862309 PMCID: PMC10164219 DOI: 10.1007/s40123-023-00693-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Accepted: 02/14/2023] [Indexed: 03/03/2023] Open
Abstract
INTRODUCTION The aim of this study was to evaluate the measurements of corneal higher-order aberrations (HOAs) obtained by a new anterior segment optical coherence tomography (OCT) technique combined with a Placido topographer (the MS-39 device) in eyes with prior small-incision lenticule extraction (SMILE) and compare them to the measurements obtained by a Scheimpflug camera combined with a Placido topographer (the Sirius device). METHODS A total of 56 eyes (56 patients) were included in this prospective study. Corneal aberrations were analyzed for the anterior, posterior, and total cornea surfaces. Within-subject standard deviation (Sw), test-retest repeatability (TRT), and intraclass correlation coefficient (ICC) were used to assess the intraobserver repeatability and interobserver reproducibility. The differences were evaluated by paired t-test. Bland-Altman plots and 95% limits of agreement (95% LoA) were used to evaluate the agreement. RESULTS High repeatability was observed for anterior and total corneal parameters, with Sw value < 0.07, TRT ≤ 0.16, and ICCs > 0.893, but not trefoil. For the posterior corneal parameters, ICCs varied from 0.088 to 0.966. Regarding interobserver reproducibility, all Sw values were ≤ 0.04 and TRT ≤ 0.11. ICCs ranged from 0.846 to 0.989, from 0.432 to 0.972, and from 0.798 to 0.985 for the anterior, total, and posterior corneal aberrations parameters, respectively. The mean difference in all aberrations was ≤ 0.05 μm. All parameters showed a narrow 95% LoA. CONCLUSION The MS-39 device achieved high precision in both anterior and total corneal measurements; the precision of posterior corneal higher-order RMS, astigmatism II, coma, and trefoil was lower. The two technologies used by the MS-39 and Sirius devices can be used interchangeably for measuring corneal HOAs after SMILE.
Collapse
|
5
|
Zhang J, Zheng L, Zhang Y, Wang K. Analysis of Asphericity and Corneal Longitudinal Spherical Aberration of 915 Chinese Myopic Adult Eyes. Clin Ophthalmol 2023; 17:591-600. [PMID: 36814783 PMCID: PMC9939669 DOI: 10.2147/opth.s404437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Accepted: 02/09/2023] [Indexed: 02/16/2023] Open
Abstract
Purpose To analyze the corneal asphericity, longitudinal spherical aberration (LSA), and related factors in Chinese myopic adult eyes. Methods This was a retrospective study of myopic adult patients. The corneal asphericity and LSA were measured at 3.0, 4.0, 5.0, 6.0, and 7.0 mm diameter apertures using corneal tomography. Age and refractive power were recorded for correlation analysis. Results In total, 531 females and 384 males were included. At the above five diameter settings the corneal asphericity values (Q) of the anterior surface were -0.09±0.21, -0.14±0.16, -0.15±0.13, -0.17±0.11, and -0.20±0.11, and those of the posterior surface were 0.23±0.49, 0.06±0.29, -0.01±0.22, -0.07±0.16, and -0.08±0.15, respectively. The anterior corneal LSA values at these diameters were 0.39±0.19, 0.63±0.27, 0.97±0.36, 0.90±0.30, and 0.83±0.29 D, respectively and the whole corneal values were 0.26±0.20, 0.44±0.27, 0.70±0.36, 0.66±0.30, and 0.59±0.28 D, respectively. Corneal asphericity and peripheral LSA showed no or weak correlation with age or spherical equivalent (all r < 0.2). Conclusion Corneal anterior and posterior Q values in myopia patients are negatively correlated with corneal diameter. Corneal anterior and whole corneal LSA increased significantly with diameter up to 5 mm, then decreased slightly with diameter. Corneal asphericity and peripheral LSA showed very weak or no correlation with age or spherical equivalent. Clinical Trial Registration Number ChiCTR1800015985.
Collapse
Affiliation(s)
- Jun Zhang
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China,Correspondence: Jun Zhang, Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China, Tel +86-18667046602; +86-0571 85064148, Email
| | - Li Zheng
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| | - Yixuan Zhang
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| | - Ke Wang
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| |
Collapse
|
6
|
Zhang J, Zheng L, Zheng C, Sun P. A Comparison of Three Cylindrical Treatment Strategies for Topography-Guided LASIK: Manifest, Topographic, and ZZ VR Cylinders. Clin Ophthalmol 2023; 17:1335-1345. [PMID: 37192993 PMCID: PMC10182812 DOI: 10.2147/opth.s408101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 05/01/2023] [Indexed: 05/18/2023] Open
Abstract
Purpose This study was designed to compare the clinical outcomes of three cylindrical treatment strategies using manifest, topographic, and Zhang & Zheng vector-compensated refraction (ZZ VR) cylinders, for topography-guided laser-assisted in situ keratomileusis (LASIK) and to identify the laser programming strategy that optimizes refractive astigmatism outcomes and visual acuity. Methods Consecutive patients referred for therapeutic refractive surgery between March and September 2018 at a single center were prospectively analyzed. Using double-masked simple randomization, patients were randomly assigned to undergo treatment based on manifest cylinder, topographic cylinder, and ZZ VR cylinder strategies. Uncorrected distance visual acuity and astigmatic refraction were analyzed preoperatively and 6 months postoperatively. Results A total of 138 eyes from 71 patients met the inclusion criteria. The manifest group consisted of 46 eyes in 24 patients, the topographic group consisted of 43 eyes in 22 patients, and the ZZ VR group consisted of 49 eyes in 25 patients. The absolute residual cylindrical refractions at 6 months postoperatively in these three groups were 0.69 ± 0.32 D, 0.58 ± 0.31 D, and 0.42 ± 0.19 D, respectively (P < 0.001; adjusted P < 0.01 for manifest vs ZZ VR, adjusted P = 0.08 for topographic vs ZZ VR). The percentages of postoperative absolute residual cylindrical power within 0.50 D in the manifest, topographic, and ZZ VR groups were 30.4%, 55.8%, and 59.2%, respectively (P = 0.01; adjusted P = 0.06 for manifest vs topographic, adjusted P = 0.02 for manifest vs ZZ VR). Conclusion The ZZ VR strategy may achieve better outcomes, as determined by cylindrical correction and visual activity, during topography-guided LASIK. Clinical Trial Registration Number ChiCTR1900025779.
Collapse
Affiliation(s)
- Jun Zhang
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
- Correspondence: Jun Zhang, Email
| | - Li Zheng
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| | - Chenyao Zheng
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| | - Peihong Sun
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| |
Collapse
|
7
|
Zhang J, Shao J, Zheng L, Zhao X, Sun Y. Changes in ocular parameters the crystalline lens after implantation of a collamer lens. Clin Exp Optom 2021; 105:587-592. [PMID: 34379036 DOI: 10.1080/08164622.2021.1958654] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
Abstract
CLINICAL RELEVANCE Understanding changes in ocular anatomical parameters after intraocular lens implantation will allow a more accurate determination of dioptric power prior to surgery. BACKGROUND The crystalline lens position might change due to the implantation and removal of an implantable collamer lens (ICL) or toric implantable collamer lens (TICL). This study aimed to assess the effect of ICL implantation on position of the crystalline lens. METHODS This retrospective study was conducted on patients who underwent V4c ICL or V4c TICL implantation between March and September, 2018. Preoperative and post-operative (2 weeks, 3 months and 6 months) axial length, central corneal thickness, crystalline lens position, crystalline lens thickness and vault height were analysed. Multivariable linear regression was used to determine the variables associated with 6-month changes in lens position. RESULTS This study included 117 eyes of 117 patients. There were decreases in all vertical distance measures from the central corneal endothelium to the anterior and posterior crystalline lens capsule (all p > 0.05). The amount of reduction was related to the crystalline lens position before the operation and crystalline lens thickness after the operation (all p < 0.01). An error in anterior chamber depth and lens thickness may appear when the ICL/TICL is close to the crystalline lens. CONCLUSION Phakic intraocular lens implantation resulted in lens thickening and forward movement on day 1 post-operatively, which becomes stable within 6 months. Preoperative lens position and post-operative lens thickness were related to the amount of movement.
Collapse
Affiliation(s)
- Jun Zhang
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, China
| | - Jie Shao
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, China
| | - Li Zheng
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, China
| | - Xia Zhao
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, China
| | - Yi Sun
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, China
| |
Collapse
|
8
|
Arba Mosquera S, Verma S. A review of clinical outcomes following SMILE for the treatment of astigmatism. EXPERT REVIEW OF OPHTHALMOLOGY 2020. [DOI: 10.1080/17469899.2020.1810017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Samuel Arba Mosquera
- Biomedical Engineering Office, Research and Development, SCHWIND Eye-tech-solutions GmbH, Kleinostheim, Germany
| | - Shwetabh Verma
- Biomedical Engineering Office, Research and Development, SCHWIND Eye-tech-solutions GmbH, Kleinostheim, Germany
| |
Collapse
|