1
|
Rana S, Anand LK, Singh M, Kapoor D, Gupta D, Kaur H. Comparative evaluation of self-pressurized Air-Q ® and Proseal™ LMA ® in patients undergoing elective surgery under general anaesthesia: A randomized clinical trial. J Anaesthesiol Clin Pharmacol 2024; 40:336-343. [PMID: 38919429 PMCID: PMC11196046 DOI: 10.4103/joacp.joacp_248_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Accepted: 03/21/2023] [Indexed: 06/27/2024] Open
Abstract
Background and Aims Intra-cuff pressure of Air-Q self-pressurized laryngeal airways (Air-Q SP) balances airway pressure and adapts to patient's pharyngeal and periglottic structures, thus improves oropharyngeal leak pressure (OLP).This study was performed to compare efficacy of Air-Q SP with Proseal laryngeal mask airway (PLMA) in patients undergoing elective surgery. Material and Methods The study design was prospective, randomized and controlled. Ninety patients were randomly assigned to Air-Q SP or PLMA group. All patients were premedicated and shifted to operation theatre. Monitoring was instituted. After securing IV-line, induction with inj. Morphine + Propofol, relaxation with inj. Vecuronium was done. Supraglottic was inserted according to group allocation. Outcome measures were OLP, fibreoptic view of larynx, success rate, device insertion parameters, haemodynamic and respiratory parameters and post-operative laryngopharyngeal complications. Neostigmine + glycopyrrolate were given, device was extubated. Results All supraglottic airway devices (SADs) were successfully placed in two attempts. The mean initial OLP, OLP at 10 minutes, and device insertion time were significantly lower in Air-Q SP group. Fiber-optic laryngeal view grading was significantly better with Air-Q SP. No significant difference was observed with respect to rate of successful insertion in first attempt, ease of insertion, and manipulations required. The hemodynamic/respiratory parameters and post-operative sore throat in the two both groups were similar. Conclusions Proseal LMA has a higher OLP than Air-Q SP but average insertion time was better, and fiber-optic grading of laryngeal view was shorter with Air-Q SP. However, Air-Q SP and Proseal LMA were both effective for lung ventilation.
Collapse
Affiliation(s)
- Savita Rana
- Department of Anaesthesia and Intensive Care, Government Medical College and Hospital, Chandigarh, India
| | - Lakesh Kumar Anand
- Department of Anaesthesia, Maharishi Markandeshwar Institute of Medical Sciences and Research, Mullana, Ambala, Haryana, India
| | - Manpreet Singh
- Department of Anaesthesia and Intensive Care, Government Medical College and Hospital, Chandigarh, India
| | - Dheeraj Kapoor
- Department of Anaesthesia and Intensive Care, Government Medical College and Hospital, Chandigarh, India
| | - Deepika Gupta
- Department of Anaesthesia and Intensive Care, Government Medical College and Hospital, Chandigarh, India
| | - Harpreet Kaur
- Department of Anaesthesia and Intensive Care, Government Medical College and Hospital, Chandigarh, India
| |
Collapse
|
2
|
Youssef MMI, Dobal NM, Hammad YM, El-Refai NAR, Abdelrahman RAA. Comparison between Air-Q Self Pressurized Airway Device with Blocker and Proseal Laryngeal Mask Airway in anesthetized paralyzed adult female patients undergoing elective gynecological operations. Anaesthesiol Intensive Ther 2024; 56:108-120. [PMID: 39166502 PMCID: PMC11284585 DOI: 10.5114/ait.2024.141203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Accepted: 12/28/2023] [Indexed: 08/23/2024] Open
Abstract
INTRODUCTION The Air-Q Self Pressurized Airway Device with Blocker (SP Blocker) was compared to the Proseal Laryngeal Mask Airway (PLMA) during positive pressure ventilation regarding the primary outcome (oropharyngeal leak pressure [OLP]), secondary outcomes (peak inspiratory pressure [PIP], inspired tidal volume [ITV], expired tidal volume [ETV], leak volume [LV] and leak fraction [LF]), insertion time, ventilation score, fiber-optic glottis view score, and postoperative laryngopharyngeal parameters (LPM). MATERIAL AND METHODS Adult healthy female patients scheduled for elective gynecological laparotomies under general anesthesia using controlled mechanical ventilation were recruited to a prospective randomized comparative clinical trial. Exclusion criteria were body mass index (BMI) ≥ 35 kg m -2 , El-Ganzouri score ≥ 5, upper airway problems, hiatus hernia or pregnancy. Patients were classified into an SP Blocker group ( n = 75) and a PLMA group ( n = 75). Primary and secondary outcomes were assessed initially and at fixed time points after successful insertion of devices. RESULTS Initially after successful device insertion: the SP Blocker group showed statistically significant higher mean OLP (cmH 2 O) (29.46 ± 2.11 vs. 28.06 ± 1.83 respectively; 95% CI: -2.037 to -0.76, P < 0.0001), lower mean PIP (cmH 2 O) (15.49 ± 0.61 vs. 17.78 ± 1.04 respectively; 95% CI: 2.02 to 2.56, P < 0.0001), higher mean ITV (mL) (411 ± 30 vs. 403 ± 15 respectively; 95% CI: -15.65 to -0.347, P = 0.041), higher mean ETV (mL) (389 ± 12 vs. 354 ± 11 respectively; 95% CI: -38.72 to -31.29, P < 0.0001), lower mean LV (mL) (22 ± 18 vs. 49 ± 10 respectively; 95% CI: 22.3 to 31.7, P < 0.0001) and lower mean LF (%) (5 ± 2.04 vs. 12 ± 6.8 respectively; 95% CI: 5.38 to 8.62, P < 0.0001) than the PLMA group. Mean insertion time (seconds) was shorter in the SP Blocker group than the PLMA group (16.39 ± 2.81 vs. 18.63 ± 3.44 respectively; 95% CI: 1.23 to 3.25, P < 0.0001). The SP Blocker group offered a better fiber-optic glottis view score than the PLMA group without differences concerning ventilation score and LPM. CONCLUSIONS SP Blocker provided as safe anesthesia during controlled mechanical ventilation as PLMA.
Collapse
|
3
|
Güth J, Jung P, Schiele A, Urban B, Parsch A, Matsche B, Eich C, Becke-Jakob K, Landsleitner B, Russo SG, Bernhard M, Hossfeld B, Olivieri M, Hoffmann F. [Update 2022: interdisciplinary statement on airway management with supraglottic airway devices in pediatric emergency medicine-The laryngeal mask is and remains state of the art : Joint statement of the Institute for Emergency Medicine and Medicine Management (INM), the University Clinic Munich, LMU Munich, Germany, the Working Group for Pediatric Critical Care and Emergency Medicine of the German Interdisciplinary Society for Critical Care and Emergency Medicine (DIVI), the Medical Directors of Emergency Medical Services in Bavaria (ÄLRD), the Scientific Working Group for Pediatric Anesthesia (WAKKA) of the German Society for Anesthesiology and Intensive Care Medicine (DGAI), the Scientific Working Group for Emergency Medicine of the German Society for Anesthesiology and Intensive Care Medicine (DGAI) and the Society of Neonatology and Pediatric Critical Care Medicine (GNPI)]. DIE ANAESTHESIOLOGIE 2023:10.1007/s00101-023-01284-2. [PMID: 37222766 DOI: 10.1007/s00101-023-01284-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Accepted: 03/30/2023] [Indexed: 05/25/2023]
Abstract
BACKGROUND Airway management with supraglottic airway devices (SGA) in life-threatening emergencies in children is increasingly being used. Different specifications of laryngeal masks (LM) and the laryngeal tube (LT) are commonly used devices for this purpose. We present a literature review and interdisciplinary consensus statement of different societies on the use of SGA in pediatric emergency medicine. MATERIAL AND METHODS Literature review in the PubMed database and classification of studies according to the criteria of the Oxford Centre for Evidence-based Medicine. Levels and consensus finding within the group of authors. RESULTS The evidence for successful applications of the various types of LM is significantly higher than for LT application. Reported smaller series of successful applications of LT are currently limited to selected research groups and centers. Especially for children below 10 kg body weight there currently exists insufficient evidence for the successful application of the LT and therefore its routine use cannot be recommended. SGAs used for emergencies should have a gastric drainage possibility. DISCUSSION Considering the scientific data and the large clinical experience with the LM in medical routine and emergency situations in children currently only the LM can be recommended for alternative (i.e., non-intubation) emergency airway management in children. If alternative airway management is part of a local emergency strategy, the LM should be provided in all pediatric sizes (1, 1½, 2, 2½, 3) for out of hospital use and in hospital emergency use and all users should regularly be trained in its application.
Collapse
Affiliation(s)
- J Güth
- Institut für Notfallmedizin und Medizinmanagement (INM), Klinikum der Universität München, München, Deutschland
| | - P Jung
- Sektion Pädiatrische Intensiv- und Notfallmedizin, Deutsche Interdisziplinäre Vereinigung für Intensiv- und Notfallmedizin (DIVI), Berlin, Deutschland
| | - A Schiele
- Ärztliche Leitung, Rettungsdienst Bayern (ÄLRD Bayern), München, Deutschland
| | - B Urban
- Institut für Notfallmedizin und Medizinmanagement (INM), Klinikum der Universität München, München, Deutschland
| | - A Parsch
- Ärztliche Leitung, Rettungsdienst Bayern (ÄLRD Bayern), München, Deutschland
| | - B Matsche
- Ärztliche Leitung, Rettungsdienst Bayern (ÄLRD Bayern), München, Deutschland
| | - C Eich
- Sektion Pädiatrische Intensiv- und Notfallmedizin, Deutsche Interdisziplinäre Vereinigung für Intensiv- und Notfallmedizin (DIVI), Berlin, Deutschland
- Wissenschaftlicher Arbeitskreis Kinderanästhesie (WAKKA), Deutsche Gesellschaft für Anästhesiologie und Intensivmedizin (DGAI), Nürnberg, Deutschland
| | - K Becke-Jakob
- Wissenschaftlicher Arbeitskreis Kinderanästhesie (WAKKA), Deutsche Gesellschaft für Anästhesiologie und Intensivmedizin (DGAI), Nürnberg, Deutschland
| | - B Landsleitner
- Sektion Pädiatrische Intensiv- und Notfallmedizin, Deutsche Interdisziplinäre Vereinigung für Intensiv- und Notfallmedizin (DIVI), Berlin, Deutschland
- Wissenschaftlicher Arbeitskreis Kinderanästhesie (WAKKA), Deutsche Gesellschaft für Anästhesiologie und Intensivmedizin (DGAI), Nürnberg, Deutschland
| | - S G Russo
- Wissenschaftlicher Arbeitskreis Kinderanästhesie (WAKKA), Deutsche Gesellschaft für Anästhesiologie und Intensivmedizin (DGAI), Nürnberg, Deutschland
| | - M Bernhard
- Wissenschaftlicher Arbeitskreis Notfallmedizin, Deutsche Gesellschaft für Anästhesiologie und Intensivmedizin (DGAI), Nürnberg, Deutschland
| | - B Hossfeld
- Sektion Pädiatrische Intensiv- und Notfallmedizin, Deutsche Interdisziplinäre Vereinigung für Intensiv- und Notfallmedizin (DIVI), Berlin, Deutschland
| | - M Olivieri
- Sektion Pädiatrische Intensiv- und Notfallmedizin, Deutsche Interdisziplinäre Vereinigung für Intensiv- und Notfallmedizin (DIVI), Berlin, Deutschland
| | - F Hoffmann
- Sektion Pädiatrische Intensiv- und Notfallmedizin, Deutsche Interdisziplinäre Vereinigung für Intensiv- und Notfallmedizin (DIVI), Berlin, Deutschland.
- Gesellschaft für Neonatologie und Pädiatrische Intensivmedizin (GNPI), Berlin, Deutschland.
- Kinderklinik und Kinderpoliklinik im Dr. von Haunerschen Kinderspital, Institut für Notfallmedizin und Medizinmanagement (INM), Ludwig-Maximilians-Universität München, Lindwurmstr. 4, 80337, München, Deutschland.
| |
Collapse
|
4
|
Li X, Wang X, Zhao Y, Jiang Z, Lv X, Nie X, Li T, Wang X, Dai L, Liu S. Incidence of postoperative sore throat after using a new technique of insertion of a second generation Laryngeal Mask Airway: A randomised controlled trial. Eur J Anaesthesiol 2021; 38:285-293. [PMID: 33186312 PMCID: PMC7932751 DOI: 10.1097/eja.0000000000001378] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND Sore throat is a common complication after Laryngeal Mask Airway Supreme (SLMA) insertion. OBJECTIVE The aim of this study was to determine whether a new SLMA insertion technique (not removing the pilot tube blocker before insertion) lowers the incidence of sore throat in the postanaesthesia care unit (PACU). DESIGN A prospective, single-centre, parallel randomised controlled trial. SETTING Operating room and PACU at a hospital in China from June to September 2019. PATIENTS Four hundred and eight patients aged 18 to 65 years with American Society of Anaesthesiologists physical status class I or II who were scheduled for elective surgery requiring anaesthesia and SLMA insertion. INTERVENTIONS Leaving the blocker at the end of the pilot tube in situ (this blocker keeps the valve open and the balloon remains partially inflated but will deflate with pressure) or removing the blocker and actively deflating the cuff before SLMA insertion. MAIN OUTCOME MEASURES The primary outcome was the incidence of postoperative sore throat in the PACU. The secondary outcomes included sore throat severity (Prince Henry Hospital Pain Score), first-attempt success rate, ease of insertion, time to successful SLMA insertion, oropharyngeal leak pressure, grade of view on fibreoptic bronchoscopy (indicating the accuracy of SLMA positioning) and adverse events. RESULTS The incidence of sore throat was 33/204 (16.2%) in the nonremoval group, and 65/204 (31.9%) in the removal group (P < 0.001). The first-attempt success rate was 174/204 (85.3%) in the nonremoval group and 150/204 (73.76%) in the removal group (P = 0.003; relative risk 1.160, 95% CI 1.049 to 1.282). The Kaplan--Meier curves showed that the insertion time in the nonremoval group was shorter (log-rank P = 0.01). CONCLUSION The new insertion technique, leaving the blocker attached to the end of the pilot balloon, resulted in a reduced incidence and severity of postoperative sore throat in the PACU, and an improved first-attempt success rate and the accuracy of SLMA positioning. TRIAL REGISTRATION Chinese Clinical Trial Registry identifier: ChiCTR1900023022.
Collapse
Affiliation(s)
- Xiaoxiao Li
- From the Jiangsu Province Key laboratory of Anaesthesiology, Xuzhou Medical University (XLi, XiuW, YZ, ZJ, XLv, XN, TL, XinW, SL), the Department of Anaesthesiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou (LD, SL), the Department of Anaesthesiology, Dushuhu Public Hospital Affiliated to Soochow University, Suzhou (XiuW), the Department of Anaesthesiology, Changzhou Maternal and Child Healthcare Hospital, Changzhou (YZ), the Department of Anaesthesiology, Suqian First Hospital, Suqian, Jiangsu, China (LD)
| | | | | | | | | | | | | | | | | | | |
Collapse
|