1
|
Girgis RE, Manandhar‐Shrestha NK, Krishnan S, Murphy ET, Loyaga‐Rendon R. Predictors of early mortality after lung transplantation for idiopathic pulmonary arterial hypertension. Pulm Circ 2024; 14:e12371. [PMID: 38646412 PMCID: PMC11027072 DOI: 10.1002/pul2.12371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 03/28/2024] [Accepted: 04/09/2024] [Indexed: 04/23/2024] Open
Abstract
Lung transplantation remains an important therapeutic option for idiopathic pulmonary arterial hypertension (IPAH), yet short-term survival is the poorest among the major diagnostic categories. We sought to develop a prediction model for 90-day mortality using the United Network for Organ Sharing database for adults with IPAH transplanted between 2005 and 2021. Variables with a p value ≤ 0.1 on univariate testing were included in multivariable analysis to derive the best subset model. The cohort comprised 693 subjects, of whom 71 died (10.2%) within 90 days of transplant. Significant independent predictors of early mortality were: extracorporeal circulatory support and/or mechanical ventilation at transplant (OR: 3; CI: 1.4-5), pulmonary artery diastolic pressure (OR: 1.3 per 10 mmHg; CI: 1.07-1.56), forced expiratory volume in the first second percent predicted (OR: 0.8 per 10%; CI: 0.7-0.94), recipient total bilirubin >2 mg/dL (OR: 3; CI: 1.4-7.2) and ischemic time >6 h (OR: 1.7, CI: 1.01-2.86). The predictive model was able to distinguish 25% of the cohort with a mortality of ≥20% from 49% with a mortality of ≤5%. We conclude that recipient variables associated with increasing severity of pulmonary vascular disease, including pretransplant advanced life support, and prolonged ischemic time are important risk factors for 90-day mortality after lung transplant for IPAH.
Collapse
Affiliation(s)
- Reda E. Girgis
- Richard Devos Heart and Lung Transplant ProgramCorewell Health and Michigan State University College of Human MedicineGrand RapidsMichiganUSA
| | - Nabin K. Manandhar‐Shrestha
- Richard Devos Heart and Lung Transplant ProgramCorewell Health and Michigan State University College of Human MedicineGrand RapidsMichiganUSA
| | - Sheila Krishnan
- Richard Devos Heart and Lung Transplant ProgramCorewell Health and Michigan State University College of Human MedicineGrand RapidsMichiganUSA
| | - Edward T. Murphy
- Richard Devos Heart and Lung Transplant ProgramCorewell Health and Michigan State University College of Human MedicineGrand RapidsMichiganUSA
| | - Renzo Loyaga‐Rendon
- Richard Devos Heart and Lung Transplant ProgramCorewell Health and Michigan State University College of Human MedicineGrand RapidsMichiganUSA
| |
Collapse
|
2
|
Oh C, Lee HC, Lee S, Shim MS, Yoon SB, Jung J, Yoon SH, Kim YH, Ko Y, Hong B, Ku Y. Continuous cardiac output estimation using a new modified Fick method during off-pump coronary artery bypass graft surgery: a retrospective observational study. J Anesth 2024; 38:1-9. [PMID: 37740733 DOI: 10.1007/s00540-023-03260-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Accepted: 09/07/2023] [Indexed: 09/25/2023]
Abstract
PURPOSE Several technical aspects of the Fick method limit its use intraoperatively. A data-driven modification of the Fick method may enable its use in intraoperative settings. METHODS This two-center retrospective observational study included 57 (28 and 29 in each center) patients who underwent off-pump coronary artery bypass graft (OPCAB) surgery. Intraoperative recordings of physiological data were obtained and divided into training and test datasets. The Fick equation was used to calculate cardiac output (CO-Fick) using ventilator-determined variables, intraoperative hemoglobin level, and SvO2, with continuous thermodilution cardiac output (CCO) used as a reference. A modification CO-Fick was derived and validated: CO-Fick-AD, which adjusts the denominator of the original equation. RESULTS Increased deviation between CO-Fick and CCO was observed when oxygen extraction was low. The root mean square error of CO-Fick was decreased from 6.07 L/min to 0.70 L/min after the modification. CO-Fick-AD showed a mean bias of 0.17 (95% CI 0.00-0.34) L/min, with a 36.4% (95% CI 30.6-44.4%) error. The concordance rates of CO-Fick-AD ranged from 73.3 to 87.1% depending on the time interval and exclusion zone. CONCLUSIONS The original Fick method is not reliable when oxygen extraction is low, but a modification using data-driven approach could enable continuous estimation of cardiac output during the dynamic intraoperative period with minimal bias. However, further improvements in precision and trending ability are needed.
Collapse
Affiliation(s)
- Chahyun Oh
- Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon, Korea
- Department of Anesthesiology and Pain Medicine, College of Medicine, Chungnam National University, Daejeon, Korea
| | - Hyung-Chul Lee
- Department of Anesthesiology and Pain Medicine Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Korea
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, Korea
| | - Soomin Lee
- Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon, Korea
- Department of Anesthesiology and Pain Medicine, College of Medicine, Chungnam National University, Daejeon, Korea
| | - Man-Shik Shim
- Department of Thoracic & Cardiovascular Surgery, Chungnam National University Hospital, Daejeon, Korea
| | - Soo Bin Yoon
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, Korea
| | - Jinsik Jung
- Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon, Korea
| | - Seok-Hwa Yoon
- Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon, Korea
- Department of Anesthesiology and Pain Medicine, College of Medicine, Chungnam National University, Daejeon, Korea
| | - Yoon-Hee Kim
- Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon, Korea
- Department of Anesthesiology and Pain Medicine, College of Medicine, Chungnam National University, Daejeon, Korea
| | - Youngkwon Ko
- Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon, Korea
- Department of Anesthesiology and Pain Medicine, College of Medicine, Chungnam National University, Daejeon, Korea
| | - Boohwi Hong
- Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon, Korea
- Department of Anesthesiology and Pain Medicine, College of Medicine, Chungnam National University, Daejeon, Korea
- Big Data Center, Biomedical Research Institute, Chungnam National University Hospital, Daejeon, Korea
| | - Yunseo Ku
- Department of Biomedical Engineering, Chungnam National University College of Medicine, 266 Munhwa-Ro(St), Jung-Gu, Daejeon, 35015, Korea.
| |
Collapse
|
3
|
Steinberg ZL, Singh HS. How to plan and perform a diagnostic catheterisation in adult patients with congenital heart disease. Heart 2022; 109:151-157. [PMID: 36261281 DOI: 10.1136/heartjnl-2022-321005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Affiliation(s)
| | - Harsimran S Singh
- Department of Internal Medicine, Weill Cornell Medical College, New York, New York, USA
| |
Collapse
|