1
|
Wang K, Xu WT, Kou WJ, Qi XS. Factors affecting cecal intubation time during colonoscopy. Shijie Huaren Xiaohua Zazhi 2023; 31:105-112. [DOI: 10.11569/wcjd.v31.i3.105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
In recent years, the morbidity and mortality of colorectal cancer (CRC) have increased significantly in China, and it has become one of the major malignancies that threaten the health of residents. Colonoscopy is the gold standard for the diagnosis of CRC. High-quality colonoscopy can effectively reduce the mortality of CRC. Cecal intubation time (CIT) is one of the indicators to reflect the quality of colonoscopy. Studies have found that many factors can affect CIT. This paper reviews the literature to identify the factors that affect CIT, such as those related to doctors, patients, assistive technologies, and equipment, in order to improve the quality of colonoscopy performed by endoscopists.
Collapse
Affiliation(s)
- Ke Wang
- Department of Gastroenterology, General Hospital of Northern Theater Command, Shenyang 110840, Liaoning Province, China,Postgraduate College, China Medical University, Shenyang 110122, Liaoning Province, China
| | - Wen-Tao Xu
- Department of Gastroenterology, General Hospital of Northern Theater Command, Shenyang 110840, Liaoning Province, China,Postgraduate College, Shenyang Pharmaceutical University, Shenyang 110016, Liaoning Province, China
| | - Wen-Jing Kou
- Department of Gastroenterology, General Hospital of Northern Theater Command, Shenyang 110840, Liaoning Province, China
| | - Xing-Shun Qi
- Department of Gastroenterology, General Hospital of Northern Theater Command, Shenyang 110840, Liaoning Province, China
| |
Collapse
|
2
|
Hsieh YH, Koo M, Tseng CW. Factors associated with prolonged cecal insertion time in patients undergoing water exchange colonoscopy. J Gastroenterol Hepatol 2022; 37:1326-1332. [PMID: 35451117 DOI: 10.1111/jgh.15869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2021] [Revised: 03/02/2022] [Accepted: 04/09/2022] [Indexed: 12/24/2022]
Abstract
BACKGROUND AND AIM Water exchange is superior to air insufflation in reducing discomfort and increasing adenoma detection during colonoscopy. However, prolonged cecal insertion time is a drawback. This study aims to investigate the factors affecting cecal insertion during water exchange colonoscopy. METHODS We pooled data from five randomized clinical trials that included patients undergoing water exchange colonoscopy. Logistic analysis was performed to determine the independent factors associated with prolonged cecal insertion time (> 15 min). RESULTS The cohort included 912 patients (493 men and 419 women) with a median age of 57 years (interquartile range, 49-64 years). The median cecal insertion time was 13.5 min (interquartile range, 10.9-17.0 min). Multivariate logistic regression analysis indicated that female sex, body mass index < 25 kg/m2 , a history of constipation, no sedation, less experienced endoscopist, Boston Bowel Preparation Scale score ≤ 6, infused water volume during insertion ≥ 1000 mL, and scope length at the cecum ≥ 85 cm were associated with prolonged cecal insertion time. With increasing volume of infused water (1000-2000 mL), the median cecal insertion time increased gradually from 11.4 to 23.0 min (P < 0.001). CONCLUSIONS The current study identified independent factors associated with prolonged cecal insertion time during water exchange colonoscopy. Several factors are modifiable to achieve a shorter insertion time, including better bowel preparation, the use of sedation, more experienced endoscopist, infusing less water during insertion, and maintaining a shorter scope length.
Collapse
Affiliation(s)
- Yu-Hsi Hsieh
- Division of Gastroenterology, Department of Internal Medicine, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan.,School of Medicine, Tzu Chi University, Hualien City, Taiwan
| | - Malcolm Koo
- Graduate Institution of Long-term Care, Tzu Chi University of Science and Technology, Hualien, Taiwan.,Dalla Lana School of Public Health, University of Toronto, Toronto, Ontario, Canada
| | - Chih-Wei Tseng
- Division of Gastroenterology, Department of Internal Medicine, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan.,School of Medicine, Tzu Chi University, Hualien City, Taiwan
| |
Collapse
|
3
|
Comparison of Procedural Sequences in Sedated Same-Day Bidirectional Endoscopy with Water-Exchange Colonoscopy: A Randomized Controlled Trial. J Clin Med 2022; 11:jcm11051365. [PMID: 35268456 PMCID: PMC8911281 DOI: 10.3390/jcm11051365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 02/21/2022] [Accepted: 02/28/2022] [Indexed: 11/25/2022] Open
Abstract
Background: Previous studies have favored esophagogastroduodenoscopy (EGD) followed by colonoscopy as the optimal sequence in bidirectional endoscopy (BDE) with air insufflation. However, the optimal sequence in same-day BDE with WE colonoscopy is unclear. Methods: A total of 200 patients undergoing BDE with propofol sedation from May 2018 to January 2021 were randomized to either the EGD-first group (n = 100) or the colonoscopy-first group (n = 100). Results: The EGD-first group required a longer cecal-intubation time (median 16.0 min vs. 13.7 min, p < 0.001) and a lower Boston Bowel Preparation Scale score (8.5 vs. 9, p = 0.030) compared with the colonoscopy-first group. However, the EGD-first group needed a significantly lower dose of propofol (200 mg vs. 250 mg, p < 0.001) and a shorter recovery time (7 min vs. 13.5 min, p < 0.001), resulting in a shorter turnover time of the endoscopy room (39.5 min vs. 42.6 min, p = 0.004). There were no differences in the sedation-related adverse events, patients’ satisfaction scores, adenoma-detection rates, or the outcomes of EGD between the two groups. Conclusions: During propofol-sedated BDE, EGD followed by WE colonoscopy was more efficient with a shorter turnover time despite a longer cecal-intubation time (NCT03638713).
Collapse
|
4
|
Fugazza A, Anderloni A, Paduano D, Badalamenti M, Maselli R, Carrara S, Gabbiadini R, Colombo M, Spadaccini M, Cappello A, Haber G, Repici A. Underwater cap-assisted endoscopic retrograde cholangiopancreatography in patients with surgically altered anatomy: a pilot study. Endoscopy 2021; 53:927-931. [PMID: 33197940 DOI: 10.1055/a-1311-9779] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Endoscopic retrograde cholangiopancreatography (ERCP) in patients with surgically altered anatomy (SAA) is technically challenging and associated with a significant number of failures. We examined the feasibility and efficacy of a novel technique for the management of bile duct stones (BDSs), called underwater cap-assisted ERCP (u-ERCP). METHODS : Between June 2019 and February 2020 all patients with SAA with jaundice or cholangitis secondary to BDSs who underwent u-ERCP were enrolled. The u-ERCP technique combines the underwater advancement of a pediatric colonoscope with a transparent cap fitted on the tip of the endoscope. We evaluated the technical success, clinical success, and adverse events associated with u-ERCP. RESULTS : We describe the technique itself and our initial experience in six patients. A complete and successful procedure was carried out in all patients, with the occurrence of no adverse events. None of the patients needed additional treatments for recurrence of symptoms during the follow-up period. CONCLUSIONS : u-ERCP can be considered as a promising alternative for successful endoscopic management of biliary disease in patients with SAA.
Collapse
Affiliation(s)
- Alessandro Fugazza
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Clinical and Research Center - IRCCS, Rozzano, Milan, Italy
| | - Andrea Anderloni
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Clinical and Research Center - IRCCS, Rozzano, Milan, Italy
| | - Danilo Paduano
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Clinical and Research Center - IRCCS, Rozzano, Milan, Italy
| | - Matteo Badalamenti
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Clinical and Research Center - IRCCS, Rozzano, Milan, Italy
| | - Roberta Maselli
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Clinical and Research Center - IRCCS, Rozzano, Milan, Italy
| | - Silvia Carrara
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Clinical and Research Center - IRCCS, Rozzano, Milan, Italy
| | - Roberto Gabbiadini
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Clinical and Research Center - IRCCS, Rozzano, Milan, Italy
| | - Matteo Colombo
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Clinical and Research Center - IRCCS, Rozzano, Milan, Italy
| | - Marco Spadaccini
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Clinical and Research Center - IRCCS, Rozzano, Milan, Italy
| | - Annalisa Cappello
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Clinical and Research Center - IRCCS, Rozzano, Milan, Italy
| | - Gregory Haber
- Division of Gastroenterology, Lenox Hill Hospital, New York, New York, USA
| | - Alessandro Repici
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Clinical and Research Center - IRCCS, Rozzano, Milan, Italy.,Humanitas University, Department of Biomedical Sciences, Pieve Emanuele, Milan, Italy
| |
Collapse
|
5
|
Wen Q, Liu KJ, Cui BT, Li P, Wu X, Zhong M, Wei L, Tu H, Yuan Y, Lin D, Hsu WH, Wu DC, Yin H, Zhang FM. Impact of cap-assisted colonoscopy during transendoscopic enteral tubing: A randomized controlled trial. World J Gastroenterol 2020; 26:6098-6110. [PMID: 33132658 PMCID: PMC7584059 DOI: 10.3748/wjg.v26.i39.6098] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 06/02/2020] [Accepted: 08/31/2020] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Colonic transendoscopic enteral tubing (TET) requires double cecal intubation, raising a common concern of how to save cecal intubation time and make the tube stable. We hypothesized that cap-assisted colonoscopy (CC) might reduce the second cecal intubation time and bring potential benefits during the TET procedure.
AIM To investigate if CC can decrease the second cecal intubation time compared with regular colonoscopy (RC).
METHODS This prospective multicenter, randomized controlled trial was performed at four centers. Subjects ≥ 7 years needing colonic TET were recruited from August 2018 to January 2020. All subjects were randomly assigned to two groups. The primary outcome was the second cecal intubation time. Secondary outcomes included success rate, insertion pain score, single clip fixation time, purpose and retention time of TET tube, length of TET tube inserted into the colon, and all procedure-related (serious) adverse events.
RESULTS A total of 331 subjects were randomized to the RC (n = 165) or CC (n = 166) group. The median time of the second cecal intubation was significantly shorter for CC than RC (2.2 min vs 2.8 min, P < 0.001). In patients with constipation, the median time of second cecal intubation in the CC group (n = 50) was shorter than that in the RC group (n = 43) (2.6 min vs 3.8 min, P = 0.004). However, no difference was observed in the CC (n = 42) and RC (n = 46) groups of ulcerative colitis patients (2.0 min vs 2.5 min, P = 0.152). The insertion pain score during the procedure in CC (n = 14) was lower than that in RC (n = 19) in unsedated colonoscopy (3.8 ± 1.7 vs 5.4 ± 1.9; P = 0.015). Multivariate analysis revealed that only CC (odds ratio [OR]: 2.250, 95% confidence interval [CI]: 1.161-4.360; P = 0.016) was an independent factor affecting the second cecal intubation time in difficult colonoscopy. CC did not affect the colonic TET tube’s retention time and length of the tube inserted into the colon. Moreover, multivariate analysis found that only endoscopic clip number (OR: 2.201, 95%CI: 1.541-3.143; P < 0.001) was an independent factor affecting the retention time. Multiple regression analysis showed that height (OR: 1.144, 95%CI: 1.027-1.275; P = 0.014) was the only independent factor influencing the length of TET tube inserted into the colon in adults.
CONCLUSION CC for colonic TET procedure is a safe and less painful technique, which can reduce cecal intubation time.
Collapse
Affiliation(s)
- Quan Wen
- Medical Center for Digestive Diseases, The Second Affiliated Hospital of Nanjing Medical University, Nanjing 210011, Jiangsu Province, China
| | - Kang-Jian Liu
- Medical Center for Digestive Diseases, The Second Affiliated Hospital of Nanjing Medical University, Nanjing 210011, Jiangsu Province, China
| | - Bo-Ta Cui
- Medical Center for Digestive Diseases, The Second Affiliated Hospital of Nanjing Medical University, Nanjing 210011, Jiangsu Province, China
| | - Pan Li
- Medical Center for Digestive Diseases, The Second Affiliated Hospital of Nanjing Medical University, Nanjing 210011, Jiangsu Province, China
| | - Xia Wu
- Medical Center for Digestive Diseases, The Second Affiliated Hospital of Nanjing Medical University, Nanjing 210011, Jiangsu Province, China
| | - Min Zhong
- Medical Center for Digestive Diseases, The Second Affiliated Hospital of Nanjing Medical University, Nanjing 210011, Jiangsu Province, China
| | - Lu Wei
- Medical Center for Digestive Diseases, The Second Affiliated Hospital of Nanjing Medical University, Nanjing 210011, Jiangsu Province, China
| | - Hua Tu
- Department of Spleen and Stomach Diseases, Hubei Provincial Hospital of Traditional Chinese Medicine, Wuhan 430061, Hubei Province, China
| | - Yu Yuan
- Department of Gastroenterology, The First Affiliated Hospital of Guangdong Pharmaceutical University, Guangzhou 510080, Guangdong Province, China
| | - Da Lin
- Department of Gastroenterology, The First Affiliated Hospital of Guangdong Pharmaceutical University, Guangzhou 510080, Guangdong Province, China
| | - Wen-Hung Hsu
- Division of Gastroenterology, Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan
| | - Deng-Chyang Wu
- Division of Gastroenterology, Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan
| | - Hong Yin
- Department of Gastroenterology, Zigong Fourth People’s Hospital, Zigong 643000, Sichuan Province, China
| | - Fa-Ming Zhang
- Medical Center for Digestive Diseases, The Second Affiliated Hospital of Nanjing Medical University, Nanjing 210011, Jiangsu Province, China
| |
Collapse
|
6
|
Lin L, Huang P. Transparent cap‐assisted, water‐exchange colonoscopy in previous incomplete difficult colonoscopy patients: A retrospective study. ADVANCES IN DIGESTIVE MEDICINE 2020. [DOI: 10.1002/aid2.13175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Lien‐Fu Lin
- Division of Hepato‐Gastroenterology, Department of Internal Medicine Tungs' Taichung Metro‐Harbor Hospital Taichung Taiwan
| | - Pi‐Teh Huang
- Division of Hepato‐Gastroenterology, Department of Internal Medicine Tungs' Taichung Metro‐Harbor Hospital Taichung Taiwan
| |
Collapse
|
7
|
Tseng CW, Koo M, Hsieh YH. Cecal intubation time between the use of one-channel and two-channel water exchange colonoscopy: A randomized controlled trial. J Gastroenterol Hepatol 2020; 35:1562-1569. [PMID: 32203986 DOI: 10.1111/jgh.15043] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Accepted: 03/16/2020] [Indexed: 01/16/2023]
Abstract
BACKGROUND AND AIM Water exchange (WE) colonoscopy is the least painful insertion technique with high adenoma detection rate but requires a longer intubation time. In the published literature, some investigators used the instrument channel for both infusing and suctioning of water (one channel), while others use colonoscopes with an integrated water-jet channel specifically designed for infusing water (two channel). The aim of this study was to compare cecal intubation time between one-channel and two-channel WE. METHODS A total 120 patients undergoing colonoscopy from May 2017 to April 2019 at a regional hospital in southern Taiwan were randomized to either a two-channel group (n = 60) or a one-channel group (n = 60). The primary outcome was cecal intubation time. RESULTS The mean cecal intubation time was significantly shorter in the two-channel group compared with the one-channel group (14.0 ± 4.0 vs 17.4 ± 6.7 min, P < 0.001). The two-channel group required less water infused during insertion (564.8 ± 232.4 vs 1213.3 ± 467.5 mL, P < 0.001) but achieved a significantly higher Boston Bowel Preparation Scale score (8.4 ± 0.8 vs 7.5 ± 1.1, P < 0.001) than did the one-channel group. The adenoma detection rate was comparable in the two groups (50.0% vs 48.3%, P = 0.855). CONCLUSIONS In comparison with the one-channel WE, two-channel WE showed a shorter cecal intubation time, required less amount of water during insertion, and provided a better salvage cleansing effect. (NCT03279705).
Collapse
Affiliation(s)
- Chih-Wei Tseng
- Division of Gastroenterology, Department of Internal Medicine, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan.,School of Medicine, Tzu Chi University, Hualien City, Taiwan
| | - Malcolm Koo
- Graduate Institute of Long-term Care, Tzu Chi University of Science and Technology, Hualien City, Hualien, Taiwan.,Dalla Lana School of Public Health, University of Toronto, Toronto, Ontario, Canada
| | - Yu-Hsi Hsieh
- Division of Gastroenterology, Department of Internal Medicine, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan.,School of Medicine, Tzu Chi University, Hualien City, Taiwan
| |
Collapse
|
8
|
Facciorusso A, Triantafyllou K, Murad MH, Prokop LJ, Tziatzios G, Muscatiello N, Singh S. Compared Abilities of Endoscopic Techniques to Increase Colon Adenoma Detection Rates: A Network Meta-analysis. Clin Gastroenterol Hepatol 2019; 17:2439-2454.e25. [PMID: 30529731 DOI: 10.1016/j.cgh.2018.11.058] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2018] [Revised: 11/22/2018] [Accepted: 11/29/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND AND AIMS Adenoma detection rate (ADR) is a quality metric for colorectal cancer screening. We performed a systematic review and network meta-analysis to assess the overall and comparative efficacies of different endoscopic techniques in adenoma detection. METHODS We performed a systematic review of published articles and abstracts, through March 15, 2018, to identify randomized controlled trials of adults undergoing colonoscopy that compared the efficacy of different devices in detection of adenomas. Our final analysis included 74 2-arm trials that comprised 44948 patients. These studies compared efficacies of add-on devices (cap, endocuff, endo-rings, G-EYE), enhanced imaging techniques (chromoendoscopy, narrow-band imaging, flexible spectral imaging color enhancement, blue laser imaging), new scopes (full-spectrum endoscopy, extra-wide-angle-view colonoscopy, dual focus), and low-cost optimizing existing resources (water-aided colonoscopy, second observer, dynamic position change), alone or in combination with high-definition colonoscopy or each other. Primary outcome was increase in ADR. We performed pairwise and network meta-analyses, and appraised quality of evidence using GRADE. RESULTS Low-cost optimizing existing resources (odds ratio [OR], 1.29; 95% CI,1.17-1.43), enhanced imaging techniques (OR,1.21; 95% CI, 1.09-1.35), and add-on devices (OR,1.18; 95% CI, 1.07-1.29) were associated with a moderate increase in ADR compared with high-definition colonoscopy; there was low to moderate confidence in estimates. Use of newer scopes was not associated with significant increases in ADR compared with high-definition colonoscopy (OR, 0.98; 95% CI, 0.79-1.21). In our comparative efficacy analysis, no specific technology for increasing ADR was superior to others. We did not find significant differences between technologies in detection of advanced ADR, polyp detection rate, or mean number of adenomas/patient. CONCLUSIONS In a network meta-analysis of published trials, we found that low-cost optimization of existing resources to be as effective as enhanced endoscopic imaging, or add-on devices, in increasing ADR during high-definition colonoscopy.
Collapse
Affiliation(s)
- Antonio Facciorusso
- Gastroenterology Unit, Department of Medical Sciences, University of Foggia, Foggia, Italy.
| | - Konstantinos Triantafyllou
- Hepatogastroenterology Unit, Second Department of Internal Medicine - Propaedeutic, Research Institute and Diabetes Center, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Mohammad Hassan Murad
- Robert D. and Patricia E. Kern Center for the Science of Health Care Delivery, Mayo Clinic, Rochester, Minnesota
| | - Larry J Prokop
- Department of Library Services, Mayo Clinic, Rochester, Minnesota
| | - Georgios Tziatzios
- Hepatogastroenterology Unit, Second Department of Internal Medicine - Propaedeutic, Research Institute and Diabetes Center, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Nicola Muscatiello
- Gastroenterology Unit, Department of Medical Sciences, University of Foggia, Foggia, Italy
| | - Siddharth Singh
- Division of Gastroenterology and Biomedical Informatics, University of California San Diego, La Jolla, California; Division of Biomedical Informatics, University of California San Diego, La Jolla, California
| |
Collapse
|
9
|
Siau K, Beintaris I. My approach to water-assisted colonoscopy. Frontline Gastroenterol 2019; 10:194-197. [PMID: 31205663 PMCID: PMC6540304 DOI: 10.1136/flgastro-2018-101143] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Revised: 12/03/2018] [Accepted: 12/09/2018] [Indexed: 02/04/2023] Open
Abstract
The goal of diagnostic colonoscopy is to achieve procedural completion while maximising effectiveness, patient acceptance and safety. In recent years, international interest in water-assisted colonoscopy (WAC) has been steadily gathering pace. A plethora of high-quality randomised controlled trials and meta-analyses now offer incontrovertible evidence into the benefits of WAC, both for the endoscopist and the patient. Despite this, uptake of WAC within the UK has been limited, with the lack of educational resources representing a significant barrier. This practical step-by-step guide is aimed at both existing practitioners and trainees, with a view to promoting familiarity with WAC and potentially for incorporation into daily practice which may ultimately have a positive effect on quality of colonoscopy and patient experience.
Collapse
Affiliation(s)
- Keith Siau
- Department of Gastroenterology, Dudley Group Hospitals NHS Foundation Trust, Dudley, UK
- Medical and Dental Sciences, University of Birmingham, Birmingham, UK
| | - Iosif Beintaris
- Department of Gastroenterology, North Tees and Hartlepool NHS Foundation Trust, Stockton-on-Tees, UK
| |
Collapse
|
10
|
Abstract
The correlation between a low adenoma detection rate (ADR) and interval cancers (ICs) has made ADR one of the most important quality indicators for colonoscopy. Data from nation-wide colorectal cancer (CRC) screening programs showed that there is room for improvement in ADR in order to reduce ICs in Taiwan. Measures with and without adjunct tools have been shown to have the potential to increase ADR, with the latter being more convenient to apply without additional cost. Optimal withdrawal techniques coupled with sufficient withdrawal time, training endoscopists with emphasis on recognition of subtle characteristics of flat lesions, dynamic position changes during the withdrawal phase, removing small polyps found during insertion, and retroflexion in the right colon have all been associated with increased ADR. In particular, water exchange (WE), which is characterized using water in lieu of air and suction removal of infused water during insertion, appears to meet the needs of colonoscopy patients in Taiwan. Analyses of both primary and secondary outcome variables of recently published studies have consistently shown that WE yields higher ADR than traditional air insufflation, even in propofol-sedated patients. Colonoscopists participating in the nationwide CRC screening program in Taiwan should consider applying one or more of the above measures to improve ADR and hopefully reduce ICs.
Collapse
Affiliation(s)
- Yu-Hsi Hsieh
- Division of Gastroenterology, Department of Medicine, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan.,School of Medicine, Tzu Chi University, Hualien, Taiwan
| | - Felix W Leung
- Sepulveda Ambulatory Care Center, Veterans Affairs Greater Los Angeles Healthcare System, North Hill, CA, USA.,Division of Gastroenterology, Department of Medicine, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
| |
Collapse
|