1
|
Budenkotte T, Apostolova I, Opfer R, Krüger J, Klutmann S, Buchert R. Automated identification of uncertain cases in deep learning-based classification of dopamine transporter SPECT to improve clinical utility and acceptance. Eur J Nucl Med Mol Imaging 2024; 51:1333-1344. [PMID: 38133688 PMCID: PMC10957699 DOI: 10.1007/s00259-023-06566-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 12/08/2023] [Indexed: 12/23/2023]
Abstract
PURPOSE Deep convolutional neural networks (CNN) are promising for automatic classification of dopamine transporter (DAT)-SPECT images. Reporting the certainty of CNN-based decisions is highly desired to flag cases that might be misclassified and, therefore, require particularly careful inspection by the user. The aim of the current study was to design and validate a CNN-based system for the identification of uncertain cases. METHODS A network ensemble (NE) combining five CNNs was trained for binary classification of [123I]FP-CIT DAT-SPECT images as "normal" or "neurodegeneration-typical reduction" with high accuracy (NE for classification, NEfC). An uncertainty detection module (UDM) was obtained by combining two additional NE, one trained for detection of "reduced" DAT-SPECT with high sensitivity, the other with high specificity. A case was considered "uncertain" if the "high sensitivity" NE and the "high specificity" NE disagreed. An internal "development" dataset of 1740 clinical DAT-SPECT images was used for training (n = 1250) and testing (n = 490). Two independent datasets with different image characteristics were used for testing only (n = 640, 645). Three established approaches for uncertainty detection were used for comparison (sigmoid, dropout, model averaging). RESULTS In the test data from the development dataset, the NEfC achieved 98.0% accuracy. 4.3% of all test cases were flagged as "uncertain" by the UDM: 2.5% of the correctly classified cases and 90% of the misclassified cases. NEfC accuracy among "certain" cases was 99.8%. The three comparison methods were less effective in labelling misclassified cases as "uncertain" (40-80%). These findings were confirmed in both additional test datasets. CONCLUSION The UDM allows reliable identification of uncertain [123I]FP-CIT SPECT with high risk of misclassification. We recommend that automatic classification of [123I]FP-CIT SPECT images is combined with an UDM to improve clinical utility and acceptance. The proposed UDM method ("high sensitivity versus high specificity") might be useful also for DAT imaging with other ligands and for other binary classification tasks.
Collapse
Affiliation(s)
- Thomas Budenkotte
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany
| | - Ivayla Apostolova
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany
| | | | | | - Susanne Klutmann
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany
| | - Ralph Buchert
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany.
| |
Collapse
|
2
|
Liu Y, Zhang Q, Zhang Y, Wang J, Wu Y, Yang G, Shi J, Wang F, Xu Z, Jing H. 99mTc-Labeled FAPI SPECT Imaging in Idiopathic Pulmonary Fibrosis: Preliminary Results. Pharmaceuticals (Basel) 2023; 16:1434. [PMID: 37895905 PMCID: PMC10610005 DOI: 10.3390/ph16101434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 09/27/2023] [Accepted: 09/27/2023] [Indexed: 10/29/2023] Open
Abstract
AIM Idiopathic pulmonary fibrosis (IPF) is associated with a poor prognosis, presenting the most aggressive form of interstitial lung diseases (ILDs). Activated fibroblasts are crucial for pathological processes. Fibroblast activation protein (FAP) inhibitor (FAPI) tracers would be promising imaging agents for these diseases. The purpose of this study was to evaluate a 99mTc-labeled FAPI tracer, 99mTc-HFAPI imaging in IPF patients. METHODS Eleven IPF patients (nine males and two females; age range 55-75 year) were included in this pilot study. 99mTc-HFAPI serial whole-body scintigraphy at 5 min, 20 min, 40 min, 1 h, 2 h, 3 h, 4 h, and 6 h was acquired for dynamic biodistribution and dosimetry estimation in seven representative patients. SPECT/CT tomography fusion imaging of the chest region was performed in all patients at 4 h post-injection, which was considered as the optimal acquisition time. Dosimetry was calculated using OLINDA/EXM software (version 2.0; HERMES Medical Solutions). The quantified or semi-quantified standardized uptake values (SUVs) and lesion-to-background ratios (LBRs) of affected lung parenchyma were also calculated. The high-resolution CT (HRCT) stage was determined with visual evaluation, and the total HRCT score of each patient was measured using a weighting factor formula. Pulmonary function tests (PFTs) were recorded as well. Then, the relationships between the 99mTc-HFAPI results, disease extent on HRCT, and PFT results were investigated. RESULTS Normal physiological uptake of 99mTc-HFAPI was observed mainly in the liver, intestinal tract, pancreas, gallbladder, and to a lesser extent in the spleen, kidneys, and thyroid, with no apparent retention in the blood circulation at the late time point. The mean injected activity of 99mTc-HFAPI was 813.4 MBq (range 695.6-888.0 MBq). No subjective side effects were noticed. The average whole-body effective dose was 0.0041 mSv/MBq per patient. IPF patients exhibited elevated pulmonary 99mTc-HFAPI uptake in abnormal lung regions, which was correlated with fibrotic regions on HRCT. Among different HRCT stage groups, both SUVmax and LBR showed significant differences (p < 0.001). The higher HRCT stage demonstrated significantly higher SUVmax and LBR. A linear correlation between 99mTc-HFAPI uptake and total HRCT score was observed for SUVmax (r = 0.7839, F = 54.41, p = 0.0094) and LBR (r = 0.7402, F = 56.33, p = 0.0092). 99mTc-HFAPI uptake also had moderate correlations with PFT results. CONCLUSIONS Our preliminary data show that the 99mTc-HFAPI SPECT imaging is a promising new imaging modality in IPF patients. Investigations of its clinical value in monitoring disease progression and treatment response are needed in the future.
Collapse
Affiliation(s)
- Yu Liu
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Beijing 100730, China; (Y.L.); (Y.W.)
| | - Qian Zhang
- Department of Respiratory Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
| | - Yuwei Zhang
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Beijing 100730, China; (Y.L.); (Y.W.)
| | - Jingnan Wang
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Beijing 100730, China; (Y.L.); (Y.W.)
| | - Yitian Wu
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Beijing 100730, China; (Y.L.); (Y.W.)
- Medical Science Research Center (MRC), Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
| | - Guangjie Yang
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Beijing 100730, China; (Y.L.); (Y.W.)
| | - Jiyun Shi
- Medical Isotopes Research Center and Department of Radiation Medicine, Scchool of Basic Medical Sciences, Peking University, Beijing 100191, China (F.W.)
| | - Fan Wang
- Medical Isotopes Research Center and Department of Radiation Medicine, Scchool of Basic Medical Sciences, Peking University, Beijing 100191, China (F.W.)
| | - Zuojun Xu
- Department of Respiratory Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
| | - Hongli Jing
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Beijing 100730, China; (Y.L.); (Y.W.)
| |
Collapse
|
3
|
Schiebler T, Apostolova I, Mathies FL, Lange C, Klutmann S, Buchert R. No impact of attenuation and scatter correction on the interpretation of dopamine transporter SPECT in patients with clinically uncertain parkinsonian syndrome. Eur J Nucl Med Mol Imaging 2023; 50:3302-3312. [PMID: 37328621 PMCID: PMC10541531 DOI: 10.1007/s00259-023-06293-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Accepted: 06/05/2023] [Indexed: 06/18/2023]
Abstract
PURPOSE The benefit from attenuation and scatter correction (ASC) of dopamine transporter (DAT)-SPECT for the detection of nigrostriatal degeneration in clinical routine is still a matter of debate. The current study evaluated the impact of ASC on visual interpretation and semi-quantitative analysis of DAT-SPECT in a large patient sample. METHODS One thousand seven hundred forty consecutive DAT-SPECT with 123I-FP-CIT from clinical routine were included retrospectively. SPECT images were reconstructed iteratively without and with ASC. Attenuation correction was based on uniform attenuation maps, scatter correction on simulation. All SPECT images were categorized with respect to the presence versus the absence of Parkinson-typical reduction of striatal 123I-FP-CIT uptake by three independent readers. Image reading was performed twice to assess intra-reader variability. The specific 123I-FP-CIT binding ratio (SBR) was used for automatic categorization, separately with and without ASC. RESULTS The mean proportion of cases with discrepant categorization by the same reader between the two reading sessions was practically the same without and with ASC, about 2.2%. The proportion of DAT-SPECT with discrepant categorization without versus with ASC by the same reader was 1.66% ± 0.50% (1.09-1.95%), not exceeding the benchmark of 2.2% from intra-reader variability. This also applied to automatic categorization of the DAT-SPECT images based on the putamen SBR (1.78% discrepant cases between without versus with ASC). CONCLUSION Given the large sample size, the current findings provide strong evidence against a relevant impact of ASC with uniform attenuation and simulation-based scatter correction on the clinical utility of DAT-SPECT to detect nigrostriatal degeneration in patients with clinically uncertain parkinsonian syndrome.
Collapse
Affiliation(s)
- Tassilo Schiebler
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr, 52, 20246, Hamburg, Germany
| | - Ivayla Apostolova
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr, 52, 20246, Hamburg, Germany
| | - Franziska Lara Mathies
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr, 52, 20246, Hamburg, Germany
| | - Catharina Lange
- Department of Nuclear Medicine, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, Berlin, Germany
| | - Susanne Klutmann
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr, 52, 20246, Hamburg, Germany
| | - Ralph Buchert
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr, 52, 20246, Hamburg, Germany.
| |
Collapse
|
4
|
Kunz D, Stotz S, de Zeeuw J, Papakonstantinou A, Dümchen S, Haberecht M, Plotkin M, Bes F. Prognostic biomarkers in prodromal α-synucleinopathies: DAT binding and REM sleep without atonia. J Neurol Neurosurg Psychiatry 2023; 94:532-540. [PMID: 36725328 PMCID: PMC10314035 DOI: 10.1136/jnnp-2022-330048] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Accepted: 01/11/2023] [Indexed: 02/03/2023]
Abstract
BACKGROUND Isolated rapid eye movement (REM) sleep behaviour disorder (iRBD) is a prodromal state of clinical α-synucleinopathies such as Parkinson's disease and Lewy body dementia. The lead-time until conversion is unknown. The most reliable marker of progression is reduced striatal dopamine transporter (DAT) binding, but low availability of imaging facilities limits general use. Our prospective observational study aimed to relate metrics of REM sleep without atonia (RWA)-a hallmark of RBD-to DAT-binding ratios in a large, homogeneous sample of patients with RBD to explore the utility of RWA as a marker of progression in prodromal α-synucleinopathies. METHODS DAT single-photon emission CT (SPECT) and video polysomnography (vPSG) were performed in 221 consecutive patients with clinically suspected RBD. RESULTS vPSG confirmed RBD in 176 patients (162 iRBD, 14 phenoconverted, 45 non-synucleinopathies). Specific DAT-binding ratios differed significantly between groups, but showed considerable overlap. Most RWA metrics correlated significantly with DAT-SPECT ratios (eg, Montreal tonic vs most-affected-region: r=-0.525; p<0.001). In patients taking serotonergic/noradrenergic antidepressants or dopaminergic substances or with recent alcohol abuse, correlations were weaker, suggesting a confounding influence, unlike other possible confounders such as beta-blocker use or comorbid sleep apnoea. CONCLUSIONS In this large single-centre prospective observational study, we found evidence that DAT-binding ratios in patients with iRBD can be used to describe a continuum in the neurodegenerative process. Overlap with non-synucleinopathies and clinical α-synucleinopathies, however, precludes the use of DAT-binding ratios as a precise diagnostic marker. The parallel course of RWA metrics and DAT-binding ratios suggests in addition to existing data that RWA, part of the routine diagnostic workup in these patients, may represent a marker of progression. Based on our findings, we suggest ranges of RWA values to estimate whether patients are in an early, medium or advanced state within the prodromal phase of α-synucleinopathies, providing them with important information about time until possible conversion.
Collapse
Affiliation(s)
- Dieter Kunz
- Sleep Research & Clinical Chronobiology, Institute of Physiology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
- Clinic for Sleep- & Chronomedicine, St. Hedwig-Krankenhaus, Berlin, Germany
| | - Sophia Stotz
- Sleep Research & Clinical Chronobiology, Institute of Physiology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
- Clinic for Sleep- & Chronomedicine, St. Hedwig-Krankenhaus, Berlin, Germany
| | - Jan de Zeeuw
- Sleep Research & Clinical Chronobiology, Institute of Physiology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
- Clinic for Sleep- & Chronomedicine, St. Hedwig-Krankenhaus, Berlin, Germany
| | - Alexandra Papakonstantinou
- Sleep Research & Clinical Chronobiology, Institute of Physiology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
- Clinic for Sleep- & Chronomedicine, St. Hedwig-Krankenhaus, Berlin, Germany
| | - Susanne Dümchen
- Clinic for Sleep- & Chronomedicine, St. Hedwig-Krankenhaus, Berlin, Germany
| | - Martin Haberecht
- Clinic for Sleep- & Chronomedicine, St. Hedwig-Krankenhaus, Berlin, Germany
| | - Michail Plotkin
- Institute of Nuclear Medicine, Vivantes Hospitals, Berlin, Germany
| | - Frederik Bes
- Sleep Research & Clinical Chronobiology, Institute of Physiology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
- Clinic for Sleep- & Chronomedicine, St. Hedwig-Krankenhaus, Berlin, Germany
| |
Collapse
|
5
|
Okuda K, Hasegawa D, Kamiya T, Ichikawa H, Umeda T, Ohkubo T, Miwa K. Multicenter Study of Quantitative SPECT: Reproducibility of 99mTc Quantitation Using a Conjugated-Gradient Minimization Reconstruction Algorithm. J Nucl Med Technol 2021; 49:138-142. [PMID: 33419954 DOI: 10.2967/jnmt.120.256131] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Accepted: 01/03/2021] [Indexed: 11/16/2022] Open
Abstract
This multicenter study aimed to determine the reproducibility of quantitative SPECT images reconstructed using a commercially available method of ordered-subset conjugate-gradient minimization. Methods: A common cylindric phantom containing a 100 kBq/mL concentration of 99mTc-pertechnetate solution in a volume of 7 L was scanned under standard imaging conditions at 6 institutions using the local clinical protocol of each. Interinstitutional variation among the quantitative SPECT images was evaluated using the coefficient of variation. Dose calibrator accuracy was also investigated by measuring the same lot of commercially available 99mTc vials at each institution. Results: The respective radioactivity concentrations under standard and clinical conditions ranged from 95.71 ± 0.60 (mean ± SD) to 108.35 ± 0.36 kBq/mL and from 96.78 ± 0.64 to 108.49 ± 0.11 kBq/mL, respectively. Interinstitutional variation in radioactivity concentration was 4.20%. The bias in the radioactivity concentrations in SPECT images was associated with the accuracy of the dose calibrator at each institution. Conclusion: The reproducibility of the commercially available quantitative SPECT reconstruction method is high and comparable to that of PET, for comparatively large (∼7 L), homogeneous objects.
Collapse
Affiliation(s)
- Kyohei Okuda
- Department of Clinical Radiology, Tottori University Hospital, Yonago, Japan
| | - Daisuke Hasegawa
- Department of Radiology, Okayama Saiseikai General Hospital, Okayama, Japan
| | - Takashi Kamiya
- Division of Radiology, Department of Medical Technology, Osaka University Hospital, Suita, Japan
| | - Hajime Ichikawa
- Department of Radiology, Toyohashi Municipal Hospital, Toyohashi, Japan
| | - Takuro Umeda
- Department of Nuclear Medicine, Cancer Institution Hospital of Japan Foundation for Cancer Research, Tokyo, Japan
| | - Takushi Ohkubo
- Central Division of Radiology, Toho University Omori Medical Center, Tokyo, Japan; and
| | - Kenta Miwa
- School of Health Science, International University of Health and Welfare, Ohtawara, Japan
| |
Collapse
|
6
|
Mora-Ramirez E, Santoro L, Cassol E, Ocampo-Ramos JC, Clayton N, Kayal G, Chouaf S, Trauchessec D, Pouget JP, Kotzki PO, Deshayes E, Bardiès M. Comparison of commercial dosimetric software platforms in patients treated with 177 Lu-DOTATATE for peptide receptor radionuclide therapy. Med Phys 2020; 47:4602-4615. [PMID: 32632928 PMCID: PMC7589428 DOI: 10.1002/mp.14375] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 06/21/2020] [Accepted: 06/22/2020] [Indexed: 12/17/2022] Open
Abstract
Purpose The aim of this study was to quantitatively compare five commercial dosimetric software platforms based on the analysis of clinical datasets of patients who benefited from peptide receptor radionuclide therapy (PRRT) with 177Lu‐DOTATATE (LUTATHERA®). Methods The dosimetric analysis was performed on two patients during two cycles of PRRT with 177Lu. Single photon emission computed tomography/computed tomography images were acquired at 4, 24, 72, and 192 h post injection. Reconstructed images were generated using Dosimetry Toolkit® (DTK) from Xeleris™ and HybridRecon‐Oncology version_1.3_Dicom (HROD) from HERMES. Reconstructed images using DTK were analyzed using the same software to calculate time‐integrated activity coefficients (TIAC), and mean absorbed doses were estimated using OLINDA/EXM V1.0 with mass correction. Reconstructed images from HROD were uploaded into PLANET® OncoDose from DOSIsoft, STRATOS from Phillips, Hybrid Dosimetry Module™ from HERMES, and SurePlan™ MRT from MIM. Organ masses, TIACs, and mean absorbed doses were calculated from each application using their recommendations. Results The majority of organ mass estimates varied by <9.5% between all platforms. The highest variability for TIAC results between platforms was seen for the kidneys (28.2%) for the two patients and the two treatment cycles. Relative standard deviations in mean absorbed doses were slightly higher compared with those observed for TIAC, but remained of the same order of magnitude between all platforms. Conclusions When applying a similar processing approach, results obtained were of the same order of magnitude regardless of the platforms used. However, the comparison of the performances of currently available platforms is still difficult as they do not all address the same parts of the dosimetric analysis workflow. In addition, the way in which data are handled in each part of the chain from data acquisition to absorbed doses may be different, which complicates the comparison exercise. Therefore, the dissemination of commercial solutions for absorbed dose calculation calls for the development of tools and standards allowing for the comparison of the performances between dosimetric software platforms.
Collapse
Affiliation(s)
- Erick Mora-Ramirez
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France.,Escuela de Física - CICANUM, Universidad de Costa Rica, San José, 11501-2060, Costa Rica
| | - Lore Santoro
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier, Montpellier, F-34298, France
| | - Emmanuelle Cassol
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France.,Département de Médecine Nucléaire, Hôpitaux Toulouse, Toulouse, F-31059, France.,Faculté de Médecine Rangueil, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France
| | - Juan C Ocampo-Ramos
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France
| | - Naomi Clayton
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France
| | - Gunjan Kayal
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France.,SCK CEN, Belgian Nuclear Research Centre, Boeretang 200, Mol, BE-2400, Belgium
| | - Soufiane Chouaf
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier, Montpellier, F-34298, France
| | - Dorian Trauchessec
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier, Montpellier, F-34298, France
| | - Jean-Pierre Pouget
- Institut de Recherche en Cancérologie de Montpellier (IRCM), Inserm U1194, Université de Montpellier, Institut Régional du Cancer de Montpellier (ICM), Montpellier, F-34298, France
| | - Pierre-Olivier Kotzki
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier, Montpellier, F-34298, France.,Institut de Recherche en Cancérologie de Montpellier (IRCM), Inserm U1194, Université de Montpellier, Institut Régional du Cancer de Montpellier (ICM), Montpellier, F-34298, France
| | - Emmanuel Deshayes
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier, Montpellier, F-34298, France.,Institut de Recherche en Cancérologie de Montpellier (IRCM), Inserm U1194, Université de Montpellier, Institut Régional du Cancer de Montpellier (ICM), Montpellier, F-34298, France
| | - Manuel Bardiès
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France
| |
Collapse
|
7
|
Peters SMB, Meyer Viol SL, van der Werf NR, de Jong N, van Velden FHP, Meeuwis A, Konijnenberg MW, Gotthardt M, de Jong HWAM, Segbers M. Variability in lutetium-177 SPECT quantification between different state-of-the-art SPECT/CT systems. EJNMMI Phys 2020; 7:9. [PMID: 32048097 PMCID: PMC7013023 DOI: 10.1186/s40658-020-0278-3] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2019] [Accepted: 01/27/2020] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Quantitative SPECT imaging in targeted radionuclide therapy with lutetium-177 holds great potential for individualized treatment based on dose assessment. The establishment of dose-effect relations requires a standardized method for SPECT quantification. The purpose of this multi-center study is to evaluate quantitative accuracy and inter-system variations of different SPECT/CT systems with corresponding commercially available quantitative reconstruction algorithms. This is an important step towards a vendor-independent standard for quantitative lutetium-177 SPECT. METHODS Four state-of-the-art SPECT/CT systems were included: Discovery™ NM/CT 670Pro (GE Healthcare), Symbia Intevo™, and two Symbia™ T16 (Siemens Healthineers). Quantitative accuracy and inter-system variations were evaluated by repeatedly scanning a cylindrical phantom with 6 spherical inserts (0.5 - 113 ml). A sphere-to-background activity concentration ratio of 10:1 was used. Acquisition settings were standardized: medium energy collimator, body contour trajectory, photon energy window of 208 keV (± 10%), adjacent 20% lower scatter window, 2 × 64 projections, 128 × 128 matrix size, and 40 s projection time. Reconstructions were performed using GE Evolution with Q.Metrix™, Siemens xSPECT Quant™, Siemens Broad Quantification™ or Siemens Flash3D™ algorithms using vendor recommended settings. In addition, projection data were reconstructed using Hermes SUV SPECT™ with standardized reconstruction settings to obtain a vendor-neutral quantitative reconstruction for all systems. Volumes of interest (VOI) for the spheres were obtained by applying a 50% threshold of the sphere maximum voxel value corrected for background activity. For each sphere, the mean and maximum recovery coefficient (RCmean and RCmax) of three repeated measurements was calculated, defined as the imaged activity concentration divided by the actual activity concentration. Inter-system variations were defined as the range of RC over all systems. RESULTS RC decreased with decreasing sphere volume. Inter-system variations with vendor-specific reconstructions were between 0.06 and 0.41 for RCmean depending on sphere size (maximum 118% quantification difference), and improved to 0.02-0.19 with vendor-neutral reconstructions (maximum 38% quantification difference). CONCLUSION This study shows that eliminating sources of possible variation drastically reduces inter-system variation in quantification. This means that absolute SPECT quantification for 177Lu is feasible in a multi-center and multi-vendor setting; however, close agreement between vendors and sites is key for multi-center dosimetry and quantitative biomarker studies.
Collapse
Affiliation(s)
- Steffie M B Peters
- Department of Radiology and Nuclear Medicine, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, P.O. Box 9101, 6500, HB, Nijmegen, The Netherlands.
| | - Sebastiaan L Meyer Viol
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Niels R van der Werf
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Nick de Jong
- Department of Radiology, Section of Medical Technology, Leiden University Medical Center, Leiden, The Netherlands
| | - Floris H P van Velden
- Department of Radiology, Section of Medical Technology, Leiden University Medical Center, Leiden, The Netherlands
| | - Antoi Meeuwis
- Department of Radiology and Nuclear Medicine, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, P.O. Box 9101, 6500, HB, Nijmegen, The Netherlands
| | - Mark W Konijnenberg
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Martin Gotthardt
- Department of Radiology and Nuclear Medicine, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, P.O. Box 9101, 6500, HB, Nijmegen, The Netherlands
| | - Hugo W A M de Jong
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Marcel Segbers
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| |
Collapse
|
8
|
Brady SL, Shulkin BL. Analysis of quantitative [I-123] mIBG SPECT/CT in a phantom and in patients with neuroblastoma. EJNMMI Phys 2019; 6:31. [PMID: 31889238 PMCID: PMC6937351 DOI: 10.1186/s40658-019-0267-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Accepted: 12/02/2019] [Indexed: 11/13/2022] Open
Abstract
Purpose To determine the accuracy of quantitative SPECT, intersystem and interpatient standardized uptake value (SUV) calculation consistency for a manufacturer-independent quantitative SPECT/CT reconstruction algorithm, and the range of SUVs of normal and neoplastic tissue. Methods A NEMA body phantom with 6 spheres (ranging 10–37 mm) was filled with a known activity-to-volume ratio and used to determine the contrast recovery coefficient (CRC) for each visible sphere, and the measured SUV accuracy of those spheres and background water solution. One hundred eleven 123I-metaiodobenzylguanidine ([I-123] mIBG) SPECT/CT examinations from 43 patients were reconstructed using SUV SPECT® (HERMES Medical Solutions Inc.); 42 examinations were acquired using a GE Infinia Hawkeye 4 SPECT/CT, and 69 were acquired on a Siemens Symbia Intevo SPECT/CT. Inter scanner SUV analysis of 9 regions of normal [I-123] mIBG tissue uptake was conducted. Intrapatient mean SUV variability was calculated by measuring normal liver uptake within patients scanned on both cameras. The intensity of uptake by neoplastic tissue in the images was quantified using maximum SUV and, if present, compared over time. Results The phantom results of the visible spheres and background resulted in accuracy calculations better than 5–10% with CRC correction. Interscanner SUV variability showed no statistical difference (average p value 0.559; range 0.066–1.0) among the 9 normal tissues analyzed. Intrapatient liver mean SUV varied ≤ 16% as calculated for 28 patients (87 examinations) studied on both scanners. In one patient, a thoracic tumor evaluated over 10 time points (18 months) underwent a 74% (3.1/12.0) reduction in maximum SUV with treatment. Conclusion The results demonstrate quantitative accuracy to better than 10%, and both consistent SUV calculation between 2 different SPECT/CT scanners for 9 tissues, and low intrapatient measurement variability for quantitative SPECT/CT analysis in a pediatric population with neuroblastoma. Quantitative SPECT/CT offers the opportunity for objective analysis of tumor response using [I-123] mIBG by normalizing the uptake to injected dose and patient weight, as is done for PET.
Collapse
Affiliation(s)
- Samuel L Brady
- Department of Radiology, Cincinnati Children's Hospital Medical Center, University of Cincinnati, Cincinnati, OH, 45229, USA
| | - Barry L Shulkin
- Department of Diagnostic Imaging MS 220, St. Jude Children's Research Hospital, 262 Danny Thomas Place, Memphis, TN, 38105-3678, USA.
| |
Collapse
|
9
|
Peters SMB, van der Werf NR, Segbers M, van Velden FHP, Wierts R, Blokland KJAK, Konijnenberg MW, Lazarenko SV, Visser EP, Gotthardt M. Towards standardization of absolute SPECT/CT quantification: a multi-center and multi-vendor phantom study. EJNMMI Phys 2019; 6:29. [PMID: 31879813 PMCID: PMC6933042 DOI: 10.1186/s40658-019-0268-5] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Accepted: 12/05/2019] [Indexed: 11/29/2022] Open
Abstract
Abstract Absolute quantification of radiotracer distribution using SPECT/CT imaging is of great importance for dosimetry aimed at personalized radionuclide precision treatment. However, its accuracy depends on many factors. Using phantom measurements, this multi-vendor and multi-center study evaluates the quantitative accuracy and inter-system variability of various SPECT/CT systems as well as the effect of patient size, processing software and reconstruction algorithms on recovery coefficients (RC). Methods Five SPECT/CT systems were included: Discovery™ NM/CT 670 Pro (GE Healthcare), Precedence™ 6 (Philips Healthcare), Symbia Intevo™, and Symbia™ T16 (twice) (Siemens Healthineers). Three phantoms were used based on the NEMA IEC body phantom without lung insert simulating body mass indexes (BMI) of 25, 28, and 47 kg/m2. Six spheres (0.5–26.5 mL) and background were filled with 0.1 and 0.01 MBq/mL 99mTc-pertechnetate, respectively. Volumes of interest (VOI) of spheres were obtained by a region growing technique using a 50% threshold of the maximum voxel value corrected for background activity. RC, defined as imaged activity concentration divided by actual activity concentration, were determined for maximum (RCmax) and mean voxel value (RCmean) in the VOI for each sphere diameter. Inter-system variability was expressed as median absolute deviation (MAD) of RC. Acquisition settings were standardized. Images were reconstructed using vendor-specific 3D iterative reconstruction algorithms with institute-specific settings used in clinical practice and processed using a standardized, in-house developed processing tool based on the SimpleITK framework. Additionally, all data were reconstructed with a vendor-neutral reconstruction algorithm (Hybrid Recon™; Hermes Medical Solutions). Results RC decreased with decreasing sphere diameter for each system. Inter-system variability (MAD) was 16 and 17% for RCmean and RCmax, respectively. Standardized reconstruction decreased this variability to 4 and 5%. High BMI hampers quantification of small lesions (< 10 ml). Conclusion Absolute SPECT quantification in a multi-center and multi-vendor setting is feasible, especially when reconstruction protocols are standardized, paving the way for a standard for absolute quantitative SPECT.
Collapse
Affiliation(s)
- Steffie M B Peters
- Department of Radiology and Nuclear Medicine, Radboudumc, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands.
| | - Niels R van der Werf
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands.,Department of Medical Physics, Albert Schweitzer Hospital, Dordrecht, The Netherlands
| | - Marcel Segbers
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Floris H P van Velden
- Department of Radiology, Section of Medical Physics, Leiden University Medical Center, Leiden, The Netherlands
| | - Roel Wierts
- Department of Radiology and Nuclear Medicine, Maastricht UMC+, Maastricht, The Netherlands
| | - Koos J A K Blokland
- Department of Radiology, Section of Medical Physics, Leiden University Medical Center, Leiden, The Netherlands
| | - Mark W Konijnenberg
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Sergiy V Lazarenko
- Department of Nuclear Medicine, Noordwest Ziekenhuisgroep, Alkmaar, The Netherlands
| | - Eric P Visser
- Department of Radiology and Nuclear Medicine, Radboudumc, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - Martin Gotthardt
- Department of Radiology and Nuclear Medicine, Radboudumc, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| |
Collapse
|
10
|
Quantitative analysis of technetium-99m-sestamibi uptake and washout in parathyroid scintigraphy supports dual mechanisms of lesion conspicuity. Nucl Med Commun 2019; 40:469-476. [DOI: 10.1097/mnm.0000000000000996] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
11
|
Tzortzakakis A, Holstensson M, Hagel E, Karlsson M, Axelsson R. Intra- and Interobserver Agreement of SUV SPECT Quantitative SPECT/CT Processing Software, Applied in Clinical Settings for Patients with Solid Renal Tumors. J Nucl Med Technol 2019; 47:258-262. [PMID: 31019039 DOI: 10.2967/jnmt.118.223297] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2018] [Accepted: 01/31/2019] [Indexed: 01/10/2023] Open
Abstract
Quantification tools for SPECT/CT are a field of ongoing research among hybrid imaging techniques. A recent multicenter study evaluating SUV SPECT software on phantoms showed that quantitative SPECT/CT is reproducible in Hybrid Viewer software. The aim of our study was to evaluate the intra- and interobserver agreement of quantitative SUV SPECT measurements in clinical settings for patients with solid renal tumors. Methods: The evaluation was part of a study that examined the role of 99mTc-sestamibi SPECT/CT in the characterization of solid kidney tumors and the differentiation of renal oncocytomas from renal cell carcinomas. Quantitative evaluation of SUV measurements was performed in Hybrid Viewer PDR, version 2.5. Forty-eight renal lesions were identified and examined twice by 2 independent readers. The agreement of the SUV measurements, concerning renal tumors and adjacent renal parenchyma, was evaluated using the intraclass correlation coefficient (ICC). Results: ICC for SUVmax measurements by the same reader was 97%-99% for solid renal tumors and 92%-98% for ipsilateral healthy renal parenchyma. ICC for SUVmax measurements between readers was 87%-89% for solid renal tumors and 72%-73% for ipsilateral healthy renal parenchyma. Estimated ICC for SUVmean measurements of solid renal tumors was 95%-98% for the same reader and 86%-89% between readers. Similar results were found for SUVpeak measurements. Conclusion: The high ICCs indicate a strong agreement among SUV measurements for patients with solid renal lesions undergoing 99mTc-sestamibi SPECT/CT, not only for measurements by the same reader but also for measurements between 2 different readers.
Collapse
Affiliation(s)
- Antonios Tzortzakakis
- Division of Radiology, Department for Clinical Science, Intervention, and Technology, Karolinska Institutet and Medical Physics and Nuclear Medicine, Karolinska University Hospital, Huddinge, Sweden .,Division of Medical Imaging and Technology, Department of Neuroradiology, Karolinska University Hospital, Huddinge, Sweden
| | - Maria Holstensson
- Medical Radiation Physics and Nuclear Medicine, Functional Unit of Nuclear Medicine, Karolinska University Hospital, Huddinge, Sweden; and
| | - Eva Hagel
- Learning, Informatics, Management, and Ethics, Medical Statistics Unit, Karolinska Institutet, Stockholm, Sweden
| | - Mattias Karlsson
- Medical Radiation Physics and Nuclear Medicine, Functional Unit of Nuclear Medicine, Karolinska University Hospital, Huddinge, Sweden; and
| | - Rimma Axelsson
- Division of Radiology, Department for Clinical Science, Intervention, and Technology, Karolinska Institutet and Medical Physics and Nuclear Medicine, Karolinska University Hospital, Huddinge, Sweden.,Medical Radiation Physics and Nuclear Medicine, Functional Unit of Nuclear Medicine, Karolinska University Hospital, Huddinge, Sweden; and
| |
Collapse
|
12
|
Spatial dependence of activity concentration recovery for a conjugate gradient (Siemens xSPECT) algorithm using manufacturer-defined reconstruction presets. Nucl Med Commun 2019; 40:287-293. [PMID: 30763291 DOI: 10.1097/mnm.0000000000000960] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Siemens absolute quantitative reconstruction, xSPECT, is available with manufacturer-defined reconstruction presets to assist with optimization. This phantom study evaluates the impact of these presets on the spatial dependence of activity concentration recovery (ACR). Single-photon emission computed tomography/computed tomography scans of a 5 : 1 and 10 : 1 (sphere : background) contrast NEMA phantom were performed on a Siemens Intevo 6. Three sphere position configurations, achieved by rotating the sphere mount through 0°, 120° and 240°, were used and three replicate images of each configuration were acquired. xSPECT reconstruction was performed using 'Fast', 'Standard' and 'Best' presets. Maximum voxel and A50 threshold ACR were measured in each sphere. The average ACR per sphere was calculated across replicates. Percentage variation of ACR, about this average, for each sphere within a given configuration across replicates and also alternative configurations was calculated. Within a given sphere configuration, percentage variation for maximum voxel ACR in like-for-like spheres across replicates was within 11% for all three presets across all sphere sizes, and within 3% for 10 : 1 and 9% for 5 : 1 contrast in the three largest spheres. Substantial variation of ACR was observed when comparing like-for-like spheres in different configurations. In the three largest spheres, variation in maximum ACR of up to 35 and 32% was measured for 10 : 1 and 5 : 1 contrast, respectively. Variation in activity concentration may be substantially greater than perceived from using a single phantom configuration. The spatial dependence observed using the manufacturer presets highlights the need for evaluation of user-defined reconstruction parameters.
Collapse
|
13
|
Evaluation of quantitative 123I and 131I SPECT with Monte Carlo-based down-scatter compensation. Nucl Med Commun 2018; 39:1097-1102. [PMID: 30222722 DOI: 10.1097/mnm.0000000000000920] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Quantitative I and I single-photon emission computed tomography (SPECT) is hampered by down-scatter from the high-energy peaks. This paper presents a down-scatter compensation method, where down-scatter generated in the patient and gamma camera collimator and detector is modelled using Monte Carlo simulation in the ordered subsets expectation maximization SPECT reconstruction algorithm. MATERIALS AND METHODS The new down-scatter compensation method was compared with conventional triple energy window (TEW) scatter compensation and Gaussian convolution-based forced detection Monte Carlo methods. The comparison was made with the NEMA-IEC phantom using six spherical inserts (diameters from 10 to 37 mm) and a lung compartment. The phantom was filled with I and I solutions to known sphere-to-background concentration ratios. Spherical volumes of interest with the same diameter as the inserts were drawn on the images, and recovery coefficients for the spheres were calculated in addition to lung-to-background ratio. RESULTS The new down-scatter compensation method provided higher recovery coefficients than the TEW scatter compensation or Gaussian convolution-based forced detection Monte Carlo algorithm for both isotopes. Background activity concentration could be accurately estimated with the new down-scatter compensation method and with the TEW scatter compensation, whereas activity concentration of the spheres was severely underestimated even with the new method. CONCLUSION Down-scatter compensation with Monte Carlo-simulation effectively reduces down-scatter effects in I and I SPECT imaging.
Collapse
|
14
|
Bexelius T, Sohlberg A. Implementation of GPU accelerated SPECT reconstruction with Monte Carlo-based scatter correction. Ann Nucl Med 2018; 32:337-347. [PMID: 29564718 DOI: 10.1007/s12149-018-1252-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Accepted: 03/19/2018] [Indexed: 11/28/2022]
Abstract
OBJECTIVE Statistical SPECT reconstruction can be very time-consuming especially when compensations for collimator and detector response, attenuation, and scatter are included in the reconstruction. This work proposes an accelerated SPECT reconstruction algorithm based on graphics processing unit (GPU) processing. METHODS Ordered subset expectation maximization (OSEM) algorithm with CT-based attenuation modelling, depth-dependent Gaussian convolution-based collimator-detector response modelling, and Monte Carlo-based scatter compensation was implemented using OpenCL. The OpenCL implementation was compared against the existing multi-threaded OSEM implementation running on a central processing unit (CPU) in terms of scatter-to-primary ratios, standardized uptake values (SUVs), and processing speed using mathematical phantoms and clinical multi-bed bone SPECT/CT studies. RESULTS The difference in scatter-to-primary ratios, visual appearance, and SUVs between GPU and CPU implementations was minor. On the other hand, at its best, the GPU implementation was noticed to be 24 times faster than the multi-threaded CPU version on a normal 128 × 128 matrix size 3 bed bone SPECT/CT data set when compensations for collimator and detector response, attenuation, and scatter were included. CONCLUSIONS GPU SPECT reconstructions show great promise as an every day clinical reconstruction tool.
Collapse
Affiliation(s)
- Tobias Bexelius
- HERMES Medical Solutions, Skeppsbron 44, 111 30, Stockholm, Sweden
| | - Antti Sohlberg
- Laboratory of Clinical Physiology and Nuclear Medicine, Joint Authority for Päijät-Häme Social and Health Care, Keskussairaalankatu 7, 15850, Lahti, Finland.
| |
Collapse
|
15
|
Porter CA, Bradley KM, Hippeläinen ET, Walker MD, McGowan DR. Phantom and clinical evaluation of the effect of full Monte Carlo collimator modelling in post-SIRT yttrium-90 Bremsstrahlung SPECT imaging. EJNMMI Res 2018; 8:7. [PMID: 29356993 PMCID: PMC5778088 DOI: 10.1186/s13550-018-0361-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Accepted: 01/10/2018] [Indexed: 01/06/2023] Open
Abstract
Background Post-therapy SPECT/CT imaging of 90Y microspheres delivered to hepatic malignancies is difficult, owing to the continuous, high-energy Bremsstrahlung spectrum emitted by 90Y. This study aimed to evaluate the utility of a commercially available software package (HybridRecon, Hermes Medical Solutions AB) which incorporates full Monte Carlo collimator modelling. Analysis of image quality was performed on both phantom and clinical images in order to ultimately provide a recommendation of an optimum reconstruction for post-therapy 90Y microsphere SPECT/CT imaging. A 3D-printed anthropomorphic liver phantom was filled with 90Y with a sphere-to-background ratio of 4:1 and imaged on a GE Discovery 670 SPECT/CT camera. Datasets were reconstructed using ordered-subsets expectation maximization (OSEM) 1–7 iterations in order to identify the optimal OSEM reconstruction (5 iterations, 15 subsets). Quantitative analysis was subsequently carried out on phantom datasets obtained using four reconstruction algorithms: the default OSEM protocol (2 iterations, 10 subsets) and the optimised OSEM protocol, both with and without full Monte Carlo collimator modelling. The quantitative metrics contrast recovery (CR) and background variability (BV) were calculated. The four algorithms were then used to retrospectively reconstruct 10 selective internal radiation therapy (SIRT) patient datasets which were subsequently blind scored for image quality by a consultant radiologist. Results The optimised OSEM reconstruction (5 iterations, 15 subsets with full MC collimator modelling) increased the CR by 42% (p < 0.001) compared to the default OSEM protocol (2 iterations, 10 subsets). The use of full Monte Carlo collimator modelling was shown to further improve CR by 14% (30 mm sphere, CR = 90%, p < 0.05). The consultant radiologist had a significant preference for the optimised OSEM over the default OSEM protocol (p < 0.001), with the optimised OSEM being the favoured reconstruction in every one of the 10 clinical cases presented. Conclusions OSEM (5 iterations, 15 subsets) with full Monte Carlo collimator modelling is quantitatively the optimal image reconstruction for post-SIRT 90Y Bremsstrahlung SPECT/CT imaging. The use of full Monte Carlo collimator modelling for correction of image-degrading effects significantly increases contrast recovery without degrading clinical image quality.
Collapse
Affiliation(s)
- Charlotte A Porter
- Radiation Physics and Protection, Churchill Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, OX3 7LE, UK.
| | - Kevin M Bradley
- Department of Radiology, Churchill Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Eero T Hippeläinen
- HUS Medical Imaging Centre, Clinical Physiology and Nuclear Medicine, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Matthew D Walker
- Radiation Physics and Protection, Churchill Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, OX3 7LE, UK
| | - Daniel R McGowan
- Radiation Physics and Protection, Churchill Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, OX3 7LE, UK.,Department of Oncology, University of Oxford, Old Road Campus Research Building, Oxford, UK
| |
Collapse
|
16
|
Dual time-point quantitative SPECT-CT parathyroid imaging using a single computed tomography. Nucl Med Commun 2018; 39:3-9. [DOI: 10.1097/mnm.0000000000000761] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|