1
|
Alexander ES, Petre EN, Bodard S, Marinelli B, Sarkar D, Cornelis FH. Comparison of a Patient-Mounted Needle-Driving Robotic System versus Single-Rotation CT Fluoroscopy to Perform CT-Guided Percutaneous Lung Biopsies. J Vasc Interv Radiol 2024; 35:859-864. [PMID: 38447771 DOI: 10.1016/j.jvir.2024.02.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 02/12/2024] [Accepted: 02/25/2024] [Indexed: 03/08/2024] Open
Abstract
PURPOSE To compare the effectiveness of percutaneous lung biopsy using a patient-mounted needle-driving robotic system with that using a manual insertion of needles under computed tomography (CT) fluoroscopy guidance. MATERIALS AND METHODS In this institutional review board approved study, the cohort consisted of a series of patients who underwent lung biopsies following the intention-to-treat protocol from September 2022 to September 2023 using robot (n = 15) or manual insertion under single-rotation CT fluoroscopy (n = 66). Patient and procedure characteristics were recorded as well as outcomes. RESULTS Although age, body mass index, and skin-to-target distance were not statistically different, target size varied (median, 8 mm [interquartile range, 6.5-9.5 mm] for robot vs 12 mm [8-18 mm] for single-rotation CT fluoroscopy; P = .001). No statistical differences were observed in technical success (86.7% [13/15] vs 89.4% [59/66], P = .673), Grade 3 adverse event (AE) (6.7% [1/15] vs 12.1% [8/66], P = .298), procedural time (28 minutes [22-32 minutes] vs 19 minutes [14.3-30.5 minutes], P = .086), and patient radiation dose (3.9 mSv [3.2-5.6 mSv] vs 4.6 mSv [3.3-7.5 mSv], P = .398). In robot-assisted cases, the median angle out of gantry plane was 10° (6.5°-16°), although it was null (0°-5°) for single-rotation CT fluoroscopy (P = .001). CONCLUSIONS Robot-assisted and single-rotation CT fluoroscopy-guided percutaneous lung biopsies were similar in terms of technical success, diagnostic yield, procedural time, AEs, and radiation dose, although robot allowed for out-of-gantry plane navigation along the needle axis.
Collapse
Affiliation(s)
- Erica S Alexander
- Department of Radiology, Memorial Sloan Kettering Cancer Center (MSK), New York, New York; Weill Cornell Medical College, Medicine, New York, New York
| | - Elena N Petre
- Department of Radiology, Memorial Sloan Kettering Cancer Center (MSK), New York, New York
| | - Sylvain Bodard
- Department of Radiology, Memorial Sloan Kettering Cancer Center (MSK), New York, New York
| | - Brett Marinelli
- Department of Radiology, Memorial Sloan Kettering Cancer Center (MSK), New York, New York; Weill Cornell Medical College, Medicine, New York, New York
| | - Debkumar Sarkar
- Department of Radiology, Memorial Sloan Kettering Cancer Center (MSK), New York, New York; Weill Cornell Medical College, Medicine, New York, New York
| | - Francois H Cornelis
- Department of Radiology, Memorial Sloan Kettering Cancer Center (MSK), New York, New York; Weill Cornell Medical College, Medicine, New York, New York.
| |
Collapse
|
2
|
Arabi H, Manesh AS, Zaidi H. Innovations in dedicated PET instrumentation: from the operating room to specimen imaging. Phys Med Biol 2024; 69:11TR03. [PMID: 38744305 DOI: 10.1088/1361-6560/ad4b92] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Accepted: 05/14/2024] [Indexed: 05/16/2024]
Abstract
This review casts a spotlight on intraoperative positron emission tomography (PET) scanners and the distinctive challenges they confront. Specifically, these systems contend with the necessity of partial coverage geometry, essential for ensuring adequate access to the patient. This inherently leans them towards limited-angle PET imaging, bringing along its array of reconstruction and geometrical sensitivity challenges. Compounding this, the need for real-time imaging in navigation systems mandates rapid acquisition and reconstruction times. For these systems, the emphasis is on dependable PET image reconstruction (without significant artefacts) while rapid processing takes precedence over the spatial resolution of the system. In contrast, specimen PET imagers are unburdened by the geometrical sensitivity challenges, thanks to their ability to leverage full coverage PET imaging geometries. For these devices, the focus shifts: high spatial resolution imaging takes precedence over rapid image reconstruction. This review concurrently probes into the technical complexities of both intraoperative and specimen PET imaging, shedding light on their recent designs, inherent challenges, and technological advancements.
Collapse
Affiliation(s)
- Hossein Arabi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva 4, Switzerland
| | - Abdollah Saberi Manesh
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva 4, Switzerland
| | - Habib Zaidi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva 4, Switzerland
- Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, 9700 RB Groningen, The Netherlands
- Department of Nuclear Medicine, University of Southern Denmark, 500 Odense, Denmark
- University Research and Innovation Center, Óbuda University, Budapest, Hungary
| |
Collapse
|
3
|
Bodard S, Guinebert S, Petre EN, Alexander E, Marinelli B, Sarkar D, Cornelis FH. Percutaneous Lung Biopsies With Robotic Systems: A Systematic Review of Available Clinical Solutions. Can Assoc Radiol J 2024:8465371241242758. [PMID: 38581355 DOI: 10.1177/08465371241242758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/08/2024] Open
Abstract
Objectives: This systematic review aims to assess existing research concerning the use of robotic systems to execute percutaneous lung biopsy. Methods: A systematic review was performed and identified 4 studies involving robotic systems used for lung biopsy. Outcomes assessed were operation time, radiation dose to patients and operators, technical success rate, diagnostic yield, and complication rate. Results: One hundred and thirteen robot-guided percutaneous lung biopsies were included. Technical success and diagnostic yield were close to 100%, comparable to manual procedures. Technical accuracy, illustrated by needle positioning, showed less frequent needle adjustments in robotic guidance than in manual guidance (P < .001): 2.7 ± 2.6 (range 1-4) versus 6 ± 4 (range 2-12). Procedure time ranged from comparable to reduced by 35% on average (20.1 ± 11.3 minutes vs 31.4 ± 10.2 minutes, P = .001) compared to manual procedures. Patient irradiation ranged from comparable to reduced by an average of 40% (324 ± 114.5 mGy vs 541.2 ± 446.8 mGy, P = .001). There was no significant difference in reported complications between manual biopsy and biopsies that utilized robotic guidance. Conclusion: Robotic systems demonstrate promising results for percutaneous lung biopsy. These devices provide adequate accuracy in probe placement and could both reduce procedural duration and mitigate radiation exposure to patients and practitioners. However, this review underscores the need for larger, controlled trials to validate and extend these findings.
Collapse
Affiliation(s)
- Sylvain Bodard
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
- Department of Radiology, University of Paris Cité, Necker Hospital, Paris, France
- Laboratoire d'Imagerie Biomédicale, Sorbonne University, CNRS UMR 7371, INSERM U 1146, Paris, France
| | - Sylvain Guinebert
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Elena N Petre
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Erica Alexander
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Brett Marinelli
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Debkumar Sarkar
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Francois H Cornelis
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
- Department of Radiology, Sorbonne University, Tenon Hospital, Paris, France
- Weill Cornell Medical College, New York, NY, USA
| |
Collapse
|
4
|
Cheng K, Li L, Du Y, Wang J, Chen Z, Liu J, Zhang X, Dong L, Shen Y, Yang Z. A systematic review of image-guided, surgical robot-assisted percutaneous puncture: Challenges and benefits. MATHEMATICAL BIOSCIENCES AND ENGINEERING : MBE 2023; 20:8375-8399. [PMID: 37161203 DOI: 10.3934/mbe.2023367] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Percutaneous puncture is a common medical procedure that involves accessing an internal organ or tissue through the skin. Image guidance and surgical robots have been increasingly used to assist with percutaneous procedures, but the challenges and benefits of these technologies have not been thoroughly explored. The aims of this systematic review are to furnish an overview of the challenges and benefits of image-guided, surgical robot-assisted percutaneous puncture and to provide evidence on this approach. We searched several electronic databases for studies on image-guided, surgical robot-assisted percutaneous punctures published between January 2018 and December 2022. The final analysis refers to 53 studies in total. The results of this review suggest that image guidance and surgical robots can improve the accuracy and precision of percutaneous procedures, decrease radiation exposure to patients and medical personnel and lower the risk of complications. However, there are many challenges related to the use of these technologies, such as the integration of the robot and operating room, immature robotic perception, and deviation of needle insertion. In conclusion, image-guided, surgical robot-assisted percutaneous puncture offers many potential benefits, but further research is needed to fully understand the challenges and optimize the utilization of these technologies in clinical practice.
Collapse
Affiliation(s)
- Kai Cheng
- Yantai Affiliated Hospital of Binzhou Medical University, Yantai, Shandong 264100, China
| | - Lixia Li
- Yantai Affiliated Hospital of Binzhou Medical University, Yantai, Shandong 264100, China
| | - Yanmin Du
- Yantai Affiliated Hospital of Binzhou Medical University, Yantai, Shandong 264100, China
| | - Jiangtao Wang
- Yantai Affiliated Hospital of Binzhou Medical University, Yantai, Shandong 264100, China
| | - Zhenghua Chen
- Yantai Affiliated Hospital of Binzhou Medical University, Yantai, Shandong 264100, China
| | - Jian Liu
- Yantai Affiliated Hospital of Binzhou Medical University, Yantai, Shandong 264100, China
| | - Xiangsheng Zhang
- Yantai Affiliated Hospital of Binzhou Medical University, Yantai, Shandong 264100, China
| | - Lin Dong
- Center on Frontiers of Computing Studies, Peking University, Beijing 100089, China
| | - Yuanyuan Shen
- Yantai Affiliated Hospital of Binzhou Medical University, Yantai, Shandong 264100, China
| | - Zhenlin Yang
- Yantai Affiliated Hospital of Binzhou Medical University, Yantai, Shandong 264100, China
| |
Collapse
|
5
|
Lin Y, Xu Y, Lin J, Fu L, Sun H, Huang Z, Ooi BY, Xie S. Improving CT-guided transthoracic biopsy diagnostic yield of lung masses using intraprocedural CT and prior PET/CT fusion imaging. BMC Pulm Med 2022; 22:311. [PMID: 35964027 PMCID: PMC9375328 DOI: 10.1186/s12890-022-02108-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 08/09/2022] [Indexed: 11/22/2022] Open
Abstract
Objective The purpose of this study was to evaluate the usefulness of intraprocedural CT and prior PET/CT fusion imaging in improving the diagnostic yield of CT-guided transthoracic core-needle biopsy (CNB) in lung masses. Methods In total, 145 subjects with lung masses suspicious for malignancy underwent image-guided transthoracic CNB. According to imaging modality the subjects were divided into two groups. PET/CT images obtained no more than 14 days before the biopsy were integrated with intraprocedural CT images. The integrated or fused images were then used to plan the puncture sites. The clinical characteristics, diagnostic yield of CNB, diagnostic accuracy rate, procedure-related complications and procedure duration were recorded and compared between the two groups. Final clinical diagnosis was determined by surgical pathology or at least 6-months follow-up. The diagnostic accuracy of CNB was obtained by comparing with final clinical diagnosis. Results 145 subjects underwent CNB with adequate samples, including 76 in fusion imaging group and 69 in routine group. The overall diagnostic yield and diagnostic accuracy rate were 80.3% (53/66), 82.9% (63/76) for fusion imaging group, 70.7% (41/58), 75.4% (52/69) for routine group, respectively. In addition, the diagnostic yield for malignancy in fusion imaging group (98.1%, 52/53) was higher than that in routine group (81.3%, 39/48). No serious procedure-related complications occurred in both two groups. Conclusion CNB with prior PET/CT fusion imaging is particularly helpful in improving diagnostic yield and accurate rate of biopsy in lung masses, especially in heterogeneous ones, thus providing greater potential benefit for patients.
Collapse
Affiliation(s)
- Yue Lin
- Department of Radiology, China-Japan Friendship Hospital, No. 2 Yinghua East Street, Chaoyang District, Beijing, 100029, China
| | - Yanyan Xu
- Department of Radiology, China-Japan Friendship Hospital, No. 2 Yinghua East Street, Chaoyang District, Beijing, 100029, China
| | - Jie Lin
- Department of Pathology, China-Japan Friendship Hospital, No. 2 Yinghua East Street, Chaoyang District, Beijing, 100029, China
| | - Liping Fu
- Department of Nuclear Medicine, China-Japan Friendship Hospital, No. 2 Yinghua East Street, Chaoyang District, Beijing, 100029, China
| | - Hongliang Sun
- Department of Radiology, China-Japan Friendship Hospital, No. 2 Yinghua East Street, Chaoyang District, Beijing, 100029, China.
| | - Zhenguo Huang
- Department of Radiology, China-Japan Friendship Hospital, No. 2 Yinghua East Street, Chaoyang District, Beijing, 100029, China
| | - Bee Yen Ooi
- Department of Radiology, Hospital Seberang Jaya, Jalan Tun Hussein Onn, Seberang Perai, 13700, Penang, Malaysia
| | - Sheng Xie
- Department of Radiology, China-Japan Friendship Hospital, No. 2 Yinghua East Street, Chaoyang District, Beijing, 100029, China
| |
Collapse
|
6
|
Boekestijn I, Azargoshasb S, Schilling C, Navab N, Rietbergen D, van Oosterom MN. PET- and SPECT-based navigation strategies to advance procedural accuracy in interventional radiology and image-guided surgery. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF RADIOPHARMACEUTICAL CHEMISTRY AND BIOLOGY 2021; 65:244-260. [PMID: 34105338 DOI: 10.23736/s1824-4785.21.03361-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
INTRODUCTION Nuclear medicine has a crucial role in interventional strategies where a combination between the increasing use of targeted radiotracers and intraprocedural detection modalities enable novel, but often complex, targeted procedures in both the fields of interventional radiology and surgery. 3D navigation approaches could assist the interventional radiologist or surgeon in such complex procedures. EVIDENCE ACQUISITION This review aimed to provide a comprehensive overview of the current application of computer-assisted navigation strategies based on nuclear imaging to assist in interventional radiology and image-guided surgery. This work starts with a brief overview of the typical navigation workflow from a technical perspective, which is followed by the different clinical applications organized based on their anatomical organ of interest. EVIDENCE SYNTHESIS Although many studies have proven the feasibility of PET- and SPECT-based navigation strategies for various clinical applications in both interventional radiology and surgery, the strategies are spread widely in both navigation workflows and clinical indications, evaluated in small patient groups. Hence, no golden standard has yet been established. CONCLUSIONS Despite that the clinical outcome is yet to be determined in large patient cohorts, navigation seems to be a promising technology to translate nuclear medicine findings, provided by PET- and SPECT-based molecular imaging, to the intervention and operating room. Interventional Nuclear Medicine (iNM) has an exciting future to come using both PET- and SPECT-based navigation.
Collapse
Affiliation(s)
- Imke Boekestijn
- Department of Radiology, Section of Nuclear Medicine, Leiden University Medical Center, Leiden, the Netherlands.,Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Samaneh Azargoshasb
- Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Clare Schilling
- Head and Neck Academic Center, Department of Head and Neck Surgery, University College London Hospital, London, UK
| | - Nassir Navab
- Computer Aided Medical Procedures, Technical University of Munich, Munich, Germany.,Computer Aided Medical Procedures, Department of Computer Science, Johns Hopkins University, Baltimore, MD, USA
| | - Daphne Rietbergen
- Department of Radiology, Section of Nuclear Medicine, Leiden University Medical Center, Leiden, the Netherlands.,Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Matthias N van Oosterom
- Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands - .,Department of Urology, Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Amsterdam, the Netherlands
| |
Collapse
|
7
|
Bogoni M, Cerci JJ, Cornelis FH, Nanni C, Tabacchi E, SchÖder H, Shyn PB, Sofocleous CT, Solomon SB, Kirov AS. Practice and prospects for PET/CT guided interventions. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF... 2021; 65:20-31. [PMID: 33494585 PMCID: PMC10446123 DOI: 10.23736/s1824-4785.21.03291-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
During the past 10 years, performing real-time molecular imaging with positron emission tomography (PET) in combination with computed tomography (CT) during interventional procedures has undergone rapid development. Keeping in mind the interest of the nuclear medicine readers, an update is provided of the current workflows using real-time PET/CT in percutaneous biopsies and tumor ablations. The clinical utility of PET/CT guided biopsies in cancer patients with lung, liver, lymphoma, and bone tumors are reviewed. Several technological developments, including the introduction of new PET tracers and robotic arms as well as opportunities provided through acquiring radioactive biopsy specimens are briefly reviewed.
Collapse
Affiliation(s)
| | | | | | - Cristina Nanni
- Unit of Nuclear Medicine, S. Orsola-Malpighi Hospital, Bologna, Italy
| | - Elena Tabacchi
- Unit of Nuclear Medicine, S. Orsola-Malpighi Hospital, Bologna, Italy
| | - Heiko SchÖder
- Unit of Nuclear Medicine, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Paul B Shyn
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Constantinos T Sofocleous
- Unit of Interventional Radiology, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Stephen B Solomon
- Unit of Interventional Radiology, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Assen S Kirov
- Unit of Molecular Imaging and Therapy Physics, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA -
| |
Collapse
|