Chantadisai M, Kingpetch K. Usefulness of (99m)Tc-pertechnetate whole body scan with neck and chest SPECT/CT for detection of post-surgical thyroid remnant and metastasis in differentiated thyroid cancer patients.
Ann Nucl Med 2014;
28:674-82. [PMID:
24889127 DOI:
10.1007/s12149-014-0864-3]
[Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2014] [Accepted: 05/19/2014] [Indexed: 11/29/2022]
Abstract
OBJECTIVE
The aim of the study was to evaluate the usefulness of (99m)Tc-pertechnetate whole body scan (WBS) with neck and chest SPECT/CT for detection of post-surgical thyroid remnant and metastasis in differentiated thyroid cancer (DTC) patients.
METHODS
Fifty-six post total thyroidectomy patients were included. All patients were prospectively imaged with (99m)Tc-pertechnetate WBS with neck and chest SPECT/CT before (131)I ablation. The post-ablative (131)I WBS with SPECT/CT was performed at 5-7 days after receiving (131)I. Both scans were directly compared to determine the concordance of sites and number of remnant and metastasis.
RESULTS
Overall per-patient analysis, the percentage of concordance between two scans was 96.4%. In thyroid bed, lymph node, lung and bone subgroups, the percentage of concordance between two scans was 96.4, 92.9, 98.2 and 100%, respectively. All of them show good correlation with unweighted kappa between 0.7 and 1. Overall per-lesion analysis, the percentage of concordance between two scans was 84%. In thyroid bed, lymph node, lung and bone subgroups, the percentage of concordance between two scans was 89.5, 55, 82.6 and 50%, respectively.
CONCLUSIONS
Pre-ablative pertechnetate WBS with neck and chest SPECT/CT has good correlation for the detection of post-surgical thyroid remnant, cervical node and discrete lung nodule metastasis as compared to (131)I WBS with SPECT/CT per-patient basis. Because (131)I therapeutic activity is desired base on metastatic site and less concerning about the number of lesions, pre-ablative (99m)Tc-pertechnetate WBS with SPECT/CT was a good alternative tool to avoid radioiodine stunning in post-surgical DTC patients.