1
|
Arvind A, Nanjappa R, Gupta KK, Macedo-de-Araújo RJ, Fadel D. Lid wiper epitheliopathy: Topical review of current identification strategies and future perspectives. Cont Lens Anterior Eye 2024:102312. [PMID: 39317557 DOI: 10.1016/j.clae.2024.102312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2024] [Revised: 08/13/2024] [Accepted: 09/14/2024] [Indexed: 09/26/2024]
Abstract
Lid Wiper Epitheliopathy (LWE) is a recognized ocular condition affecting visual quality and ocular comfort, characterized by the damage of the marginal conjunctiva of the upper eyelid. This review critically examines the current strategies for LWE identification and explores the multifactorial etiology of LWE and its association with various ocular surface diseases. A literature review conducted on PubMed identified 67 relevant studies, which were analyzed to enhance understanding of LWE's diagnostic criteria and its clinical implications, offering future perspectives on improving diagnostic accuracy and patient outcomes. The association between LWE and contact lens-related discomfort is examined, with studies reporting conflicting findings regarding its prevalence and severity among soft contact lens wearers. Moreover, LWE has been linked to tear film abnormalities, altered tear composition, and eyelid margin abnormalities in non-contact lens wearers, further complicating diagnosis and management. Current LWE grading systems, including subjective methods and semi-objective approaches, are reviewed, highlighting challenges such as subjectivity, complexity, and variability. Recent advances in LWE grading, including semi-automated methods and photographic scales, show promise but face implementation challenges in clinical settings. The review concludes by proposing areas for further research, including investigating factors contributing to LWE onset and development, developing more sensitive diagnostic tools, and exploring the impact of LWE on ocular surface health and visual function. Standardization, validation, and innovation in grading systems are emphasized to enhance diagnostic accuracy and improve clinical outcomes for patients with LWE. Ongoing research in LWE grading is essential for addressing diagnostic challenges and optimizing assessment methodologies in clinical practice.
Collapse
Affiliation(s)
- Anitha Arvind
- Department of Optometry, School of Healthcare and Allied Sciences, GD Goenka University, Gurugram, India.
| | - Rakesh Nanjappa
- Department of Optometry, School of Healthcare and Allied Sciences, GD Goenka University, Gurugram, India
| | - Krishna Kumar Gupta
- Department of Optometry, School of Healthcare and Allied Sciences, GD Goenka University, Gurugram, India
| | - Rute J Macedo-de-Araújo
- Clinical & Experimental Optometry Research Lab (CEORLab), Center of Physics, University of Minho, Braga, Portugal; Physics Center of Minho and Porto Universities (CF-UM-UP), University of Minho, Braga, Portugal
| | - Daddi Fadel
- Center for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada; School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| |
Collapse
|
2
|
Maldonado-Codina C, Navascues-Cornago M, Smith SL, Read ML, Lakkis C, Morgan PB. End-of-day assessment of asymptomatic versus highly symptomatic soft contact lens wearers. Ophthalmic Physiol Opt 2024; 44:704-717. [PMID: 38546401 DOI: 10.1111/opo.13305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 03/08/2024] [Accepted: 03/10/2024] [Indexed: 05/01/2024]
Abstract
PURPOSE To investigate differences in key clinical parameters between asymptomatic and highly symptomatic soft contact lens (CL) wearers after 14 h of wear. METHODS In this pilot investigation, Phase 1 identified asymptomatic (CLDEQ-8 score ≤ 7) and highly symptomatic (CLDEQ-8 score ≥ 20) subjects after fitting with nelfilcon A CLs. Phase 2 investigated the following over a single nelfilcon A CL-wearing day (14 ± 2 h): blinking characteristics, tear meniscus height (TMH), non-invasive tear break-up time (NIBUT), tear film osmolarity and eyelid margin staining. Parameters for the two groups were compared using linear mixed models and post-hoc testing. The relationship between comfort scores and the clinical parameters was also investigated. RESULTS Overall, 161 and 42 subjects were enrolled into Phase 1 and 2, respectively. Twenty-five asymptomatic and 17 symptomatic subjects completed Phase 2. Lower eyelid TMH was decreased after 14 h in symptomatic compared with asymptomatic subjects (least square mean [LSM] difference -0.04 mm, 95% CI: -0.07, -0.01). Osmolarity was lower in symptomatic than in asymptomatic subjects at fitting (LSM difference -9.89, 95% CI: -18.91, -0.86). Upper eyelid margin staining was greater after 14 h in symptomatic than in asymptomatic subjects (LSM difference 0.53, 95% CI: 0.01, 1.05) and greater after 14 h than baseline in the symptomatic group (LSM difference 0.61, 95% CI: 0.16, 1.07). There was a significant relationship between comfort and upper eyelid margin staining (r = -0.40, 95% CI: -0.63, -0.11) and blink rate (r = -0.31, 95% CI: -0.57, -0.003). CONCLUSION The potential parameters most effective in differentiating asymptomatic from symptomatic wearers were upper eyelid margin staining and lower TMH. The parameter with the strongest relationship to comfort was upper eyelid margin staining, where higher comfort scores were associated with lower levels of staining.
Collapse
Affiliation(s)
- Carole Maldonado-Codina
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Maria Navascues-Cornago
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Sarah L Smith
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Michael L Read
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Carol Lakkis
- Johnson & Johnson Vision Care, Inc., Jacksonville, Florida, USA
- iBiomedical Consulting Pty Ltd, Melbourne, Victoria, Australia
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| |
Collapse
|
3
|
Jones L, Efron N, Bandamwar K, Barnett M, Jacobs DS, Jalbert I, Pult H, Rhee MK, Sheardown H, Shovlin JP, Stahl U, Stanila A, Tan J, Tavazzi S, Ucakhan OO, Willcox MDP, Downie LE. TFOS Lifestyle: Impact of contact lenses on the ocular surface. Ocul Surf 2023; 29:175-219. [PMID: 37149139 DOI: 10.1016/j.jtos.2023.04.010] [Citation(s) in RCA: 18] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 05/08/2023]
Abstract
Several lifestyle choices made by contact lens wearers can have adverse consequences on ocular health. These include being non-adherent to contact lens care, sleeping in lenses, ill-advised purchasing options, not seeing an eyecare professional for regular aftercare visits, wearing lenses when feeling unwell, wearing lenses too soon after various forms of ophthalmic surgery, and wearing lenses when engaged in risky behaviors (e.g., when using tobacco, alcohol or recreational drugs). Those with a pre-existing compromised ocular surface may find that contact lens wear exacerbates ocular disease morbidity. Conversely, contact lenses may have various therapeutic benefits. The coronavirus disease-2019 (COVID-19) pandemic impinged upon the lifestyle of contact lens wearers, introducing challenges such as mask-associated dry eye, contact lens discomfort with increased use of digital devices, inadvertent exposure to hand sanitizers, and reduced use of lenses. Wearing contact lenses in challenging environments, such as in the presence of dust and noxious chemicals, or where there is the possibility of ocular trauma (e.g., sport or working with tools) can be problematic, although in some instances lenses can be protective. Contact lenses can be worn for sport, theatre, at high altitude, driving at night, in the military and in space, and special considerations are required when prescribing in such situations to ensure successful outcomes. A systematic review and meta-analysis, incorporated within the review, identified that the influence of lifestyle factors on soft contact lens dropout remains poorly understood, and is an area in need of further research. Overall, this report investigated lifestyle-related choices made by clinicians and contact lens wearers and discovered that when appropriate lifestyle choices are made, contact lens wear can enhance the quality of life of wearers.
Collapse
Affiliation(s)
- Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
| | - Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - Kalika Bandamwar
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, USA
| | - Deborah S Jacobs
- Massachusetts Eye & Ear, Harvard Medical School, Boston, MA, USA
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Heiko Pult
- Dr Heiko Pult Optometry & Vision Research, Weinheim, Germany
| | | | - Heather Sheardown
- Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| | | | - Ulli Stahl
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada
| | | | - Jacqueline Tan
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Silvia Tavazzi
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | | | - Mark D P Willcox
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
4
|
Jiang H, Fang M, Franklin R, Simms AG, Fadli Z, Wang J. Associations Between Lid Wiper Microvascular Responses, Lens Fit, and Comfort After One Day of Contact Lens Adaptation by Neophytes. Eye Contact Lens 2022; 48:340-346. [PMID: 35580543 PMCID: PMC9329170 DOI: 10.1097/icl.0000000000000898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/29/2022] [Indexed: 11/26/2022]
Abstract
PURPOSE To determine associations between lid wiper microvascular responses, lens fit, and comfort after 1 day of contact lens adaptation by neophytes. METHODS Functional slitlamp biomicroscopy was used to image the microvascular network of the upper tarsal conjunctiva, lid wiper, and bulbar conjunctiva. Fractal dimension was obtained to represent vessel density. Ultra-high-resolution optical coherence tomography was used to image the lens edge and fitting characteristics, including lens movement and lens-induced conjunctival indentation. Ocular comfort was rated using a 50-point visual analogue scale (VAS). Forty-nine healthy subjects without a history of contact lens wear were recruited. A contact lens was then fitted in the right eye. Imaging was taken at baseline and 6 hr after lens wear. RESULTS The changes of VAS comfort score were negatively related to the changes of the vessel density in the lid-wiper (R 2 =0.18, P =0.002) and bulbar conjunctiva (R 2 =0.13, P =0.009). However, the changes of VAS were positively related to the changes in vessel density of the tarsal conjunctiva (R 2 =0.11, P =0.02). The changes of ocular microvasculature were not related to the objective metrics of the lens-fitting characteristics ( P >0.05). Similarly, the changes in the VAS comfort score were not related to the objective metrics of the lens-fitting characteristics ( P >0.05). CONCLUSION Contact lens discomfort seemed to relate to lid wiper microvascular responses rather than fitting characteristics after 1 day of contact lens adaptation by neophytes.
Collapse
Affiliation(s)
- Hong Jiang
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
- Department of Neurology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Min Fang
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
- Shenzhen Key Laboratory of Ophthalmology, Shenzhen Eye Hospital, Jinan University, Shenzhen, Guangdong, China
| | - Ross Franklin
- Johnson & Johnson Vision Care, Inc, Jacksonville, FL, USA
| | - Ava-Gaye Simms
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Zohra Fadli
- Johnson & Johnson Vision Care, Inc, Jacksonville, FL, USA
| | - Jianhua Wang
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| |
Collapse
|
5
|
Walsh K, Jones L, Moody K. Addressing common myths and misconceptions in soft contact lens practice. Clin Exp Optom 2021; 105:459-473. [PMID: 34886744 DOI: 10.1080/08164622.2021.2003693] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
Advances in contact lens technology over the past 50 years since the commercialisation of the first soft lenses in 1971 have been incredible, with significant changes in contact lens materials, frequency of replacement, care systems and lens designs occurring. However, despite the widespread availability of contact lenses, penetration rates for those who need vision correction remain in the low single digits and many practitioners seem to hold on to concepts around the potential value of contact lenses that appear based in the dim and distant past and are certainly no longer valid today. This review addresses 10 common 'myths and misconceptions' around soft contact lenses using an evidence-based approach that can hopefully dispel some of these incorrect assumptions.
Collapse
Affiliation(s)
- Karen Walsh
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada.,Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Shatin, Hong Kong
| | - Kurt Moody
- Johnson & Johnson Vision, Jacksonville, Florida, USA
| |
Collapse
|
6
|
Alghamdi WM, Markoulli M, Papas EB. Filaggrin Expression in the Lid Margin During Contact Lens Wear. Eye Contact Lens 2021; 47:638-641. [PMID: 34173367 DOI: 10.1097/icl.0000000000000805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/14/2021] [Indexed: 11/25/2022]
Abstract
AIM To investigate the expression of the keratinization-related protein, filaggrin, in the lid margin epithelium of contact lens (CL) wearers compared with nonwearers. METHODS This was a cross-sectional study of 100 individuals with different exposures to CL wear: short, moderate, and long experience; previous CL wearers; and nonwearers as controls. Impression cytology samples were collected from the lid wiper (LW) area of the central upper lid margin. After fixing, an equal, random sample was selected from each group (n=13) for immunocytochemistry analysis using antihuman primary anybody (mouse filaggrin), then stained with secondary antibody (fluorescein isothiocyanate-conjugated donkey anti-mouse immunoglobulin G horseradish peroxidase) to detect filaggrin. Imaging was performed with the 3i-Vivo 2-photon microscope equipped with a Zeiss 20×-objective and SlideBook-reader software. RESULTS Sixty-five samples from 65 participants (37 women; mean age±SD: 25.1±4.1 years) were collected. Filaggrin was detected in all 65 randomly selected immunostained marginal epithelium samples. All samples were similar in showing patchy areas of filaggrin immunostaining, regardless of CL wear, symptoms or epithelium morphology. Because the filaggrin immunostaining showed similar patterns across almost all the observed samples, comparison between subject groups was impractical. The presence of filaggrin in the healthy LW was additionally confirmed by an independent laboratory. CONCLUSION Filaggrin expression seems to be a normal part of epithelial cell differentiation in the lid margin and may not be a useful keratinization/stress biomarker in the marginal epithelium. Investigating other keratinization biomarkers that are not detected in the normal mucocutaneous junction/LW may help to understand the keratinization nature of LW epithelium changes in CL wearers.
Collapse
Affiliation(s)
- Waleed M Alghamdi
- Department of Optometry (W.A.), College of Applied Medical Science, Qassim University, Qassim, Saudi Arabia; and School of Optometry & Vision Science (W.A., M.M., E.P.), University of New South Wales, Sydney, Australia
| | | | | |
Collapse
|
7
|
Natural course of lid wiper epitheliopathy (LWE) in symptomatic contact lens wearers. Cont Lens Anterior Eye 2021; 45:101529. [PMID: 34716094 DOI: 10.1016/j.clae.2021.101529] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 10/11/2021] [Accepted: 10/20/2021] [Indexed: 11/21/2022]
Abstract
PURPOSE To establish the time course of lid wiper epitheliopathy (LWE) in established CL wearers after a single day (6-10 h) of daily disposable contact lens (CL) wear, the following day post-CL removal and 1-week after CL discontinuation. METHODS Twenty-one symptomatic (CLDEQ-8 score ≥ 12) habitual wearers of MyDay® silicone hydrogel daily disposable were included. LWE staining was assessed prior to CL wear (Visit 1, V1) using semi-automated analysis after instillation of two drops of 1 % lissamine green (10 μL) that were applied to the superior bulbar conjunctiva. LWE measurements were repeated after 6-10 h of continuous CL wear (Visit 2, V2), post-CL removal the following day (Visit 3, V3) and after 1-week CL discontinuation (Visit 4, V4). At each visit, ocular symptoms were evaluated using the SPEED-8 questionnaire and set of 0-100 visual analogue scales (VAS). RESULTS LWE showed no significant changes after 6-10 h of continuous CL wear (p = 0.536), post-CL removal the following day (p = 0.677) or following 1-week of CL discontinuation (p = 0.478). Analysis revealed a significant improvement in symptomatology between V1 and V2 (SPEED-8, p < 0.01) and also improvements in the 0-100 VAS scores between V2 and V4 for average daily dryness (p < 0.01), end-of-day dryness (p < 0.01) and frequency of end-of-day dryness (p < 0.05). CONCLUSION The present data suggest that the etiology of LWE is multifactorial and the sole intervention of temporarily discontinuing CL wear does not lead to resolution of these clinical signs.
Collapse
|
8
|
Fang M, Airen S, Jiang H, Wang J. Ocular surface microvascular response and its relation to contact lens fitting and ocular comfort: an update of recent research. Clin Exp Optom 2021; 104:661-671. [PMID: 33689669 DOI: 10.1080/08164622.2021.1878867] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
This review examines vascular responses in the ocular surface to contact lens wear and its relation to lens fitting characteristics and contact lens-related discomfort. A search of PubMed was performed to find original research in English, within the past 10 years, that studied the ocular surface, including lid-wiper vascular responses to the lens. The interaction between the lens and ocular surface triggers vascular responses, impacting the lens fitting and contact lens-related discomfort. Contact lens-related discomfort is a multifactorial event, which is affected by lens characteristics. Overall, contact lenses with low modulus and a relatively tight fit produce significant ocular comfort. If an appropriate lens fit is achieved, lens fitting characteristics may not play a critical role in contact lens-related discomfort. On the other hand, the pathogenic and vascular changes of lid-wiper vascular responses appear to play an essential role in developing contact lens-related discomfort, in concert with reactions of the cornea (compression and staining) and conjunctiva (indentation and staining). Robust evaluation of lid-wiper changes at the cellular and microvascular level may hold the key to better understanding the mechanism of contact lens-related discomfort and reveal strategies for eliminating lid wiper epitheliopathy and improving ocular comfort in contact lens wearers.
Collapse
Affiliation(s)
- Min Fang
- Shenzhen Key Laboratory of Ophthalmology, Shenzhen Eye Hospital, Jinan University, Shenzhen, Guangdong, China.,School of Medicine, Bascom Palmer Eye Institute, University of Miami Miller, Miami, FL, USA
| | - Shriya Airen
- School of Medicine, University of Miami Miller, Miami, FL, USA
| | - Hong Jiang
- School of Medicine, Bascom Palmer Eye Institute, University of Miami Miller, Miami, FL, USA.,Department of Neurology, School of Medicine, University of Miami Miller, Miami, FL, USA
| | - Jianhua Wang
- School of Medicine, Bascom Palmer Eye Institute, University of Miami Miller, Miami, FL, USA
| |
Collapse
|
9
|
CLEAR - Contact lens wettability, cleaning, disinfection and interactions with tears. Cont Lens Anterior Eye 2021; 44:157-191. [DOI: 10.1016/j.clae.2021.02.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
|
10
|
CLEAR - Contact lens complications. Cont Lens Anterior Eye 2021; 44:330-367. [DOI: 10.1016/j.clae.2021.02.010] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Accepted: 02/01/2021] [Indexed: 12/20/2022]
|
11
|
Morgan PB, Murphy PJ, Gifford KL, Gifford P, Golebiowski B, Johnson L, Makrynioti D, Moezzi AM, Moody K, Navascues-Cornago M, Schweizer H, Swiderska K, Young G, Willcox M. CLEAR - Effect of contact lens materials and designs on the anatomy and physiology of the eye. Cont Lens Anterior Eye 2021; 44:192-219. [PMID: 33775377 DOI: 10.1016/j.clae.2021.02.006] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/19/2022]
Abstract
This paper outlines changes to the ocular surface caused by contact lenses and their degree of clinical significance. Substantial research and development to improve oxygen permeability of rigid and soft contact lenses has meant that in many countries the issues caused by hypoxia to the ocular surface have largely been negated. The ability of contact lenses to change the axial growth characteristics of the globe is being utilised to help reduce the myopia pandemic and several studies and meta-analyses have shown that wearing orthokeratology lenses or soft multifocal contact lenses can reduce axial length growth (and hence myopia). However, effects on blinking, ptosis, the function of Meibomian glands, fluorescein and lissamine green staining of the conjunctiva and cornea, production of lid-parallel conjunctival folds and lid wiper epitheliopathy have received less research attention. Contact lens wear produces a subclinical inflammatory response manifested by increases in the number of dendritiform cells in the conjunctiva, cornea and limbus. Papillary conjunctivitis is also a complication of all types of contact lenses. Changes to wear schedule (daily disposable from overnight wear) or lens materials (hydrogel from SiHy) can reduce papillary conjunctivitis, but the effect of such changes on dendritic cell migration needs further study. These changes may be associated with decreased comfort but confirmatory studies are needed. Contact lenses can affect the sensitivity of the ocular surface to mechanical stimulation, but whether these changes affect comfort requires further investigation. In conclusion, there have been changes to lens materials, design and wear schedules over the past 20+ years that have improved their safety and seen the development of lenses that can reduce the myopia development. However, several changes to the ocular surface still occur and warrant further research effort in order to optimise the lens wearing experience.
Collapse
Affiliation(s)
- Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK.
| | - Paul J Murphy
- University of Waterloo, School of Optometry and Vision Science, Waterloo, Canada
| | - Kate L Gifford
- School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Australia
| | - Paul Gifford
- School of Optometry and Vision Science, UNSW Sydney, Australia
| | | | - Leah Johnson
- CooperVision Specialty EyeCare, Gilbert, AZ, United States
| | - Dimitra Makrynioti
- School of Health Rehabilitation Sciences, University of Patras (Aigio), Greece
| | - Amir M Moezzi
- Centre for Ocular Research and Education, University of Waterloo, Canada
| | - Kurt Moody
- Johnson & Johnson Vision Care, Jacksonville, FL, United States
| | | | | | - Kasandra Swiderska
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK
| | | | - Mark Willcox
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|
12
|
Lievens CW, Norgett Y, Briggs N, Allen PM, Vianya-Estopa M. Impact of Improper Approach to Identify Lid Wiper Epitheliopathy (LWE). Clin Ophthalmol 2020; 14:3039-3047. [PMID: 33116355 PMCID: PMC7547802 DOI: 10.2147/opth.s273524] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Accepted: 09/11/2020] [Indexed: 01/09/2023] Open
Abstract
Purpose Variability in the use of ophthalmic dyes to diagnose lid wiper epitheliopathy (LWE) has led to division in the literature and clinical practice. The principal aim of this study was to evaluate whether the use of a non-optimal methodology to identify LWE had a potential for false negatives; in which LWE was overlooked. Patients and Methods A total of 20 participants were initially categorized to not have LWE and were enrolled in this study. The protocol examined whether or not LWE would later be revealed through the use of optimized methodology. Semi-automated analysis was performed of images taken after two different drop instillations with varying post-dye viewing times for both lissamine green (LG) and sodium fluorescein (NaFl). Results There was a significant increase in area of staining revealed when an optimal methodology for LWE identification was used. Comparisons for every non-optimal condition were statistically significantly different against the optimal condition (all p<0.01). The use of a non-optimal methodology resulted in a 70% false-negative rate when using LG and a 95% false-negative rate when using NaFl. Conclusion The study demonstrated that using a double instillation of dye was statistically different from a single-dose, even with extended wait time for clinical observation. A single instillation did not offer adequate volume of dye for adequate lid margin uptake. A careful adherence to volume as well as a repeat administration is key to revealing the full area of LWE. A non-optimal approach to diagnose LWE can lead to false negatives.
Collapse
Affiliation(s)
| | - Yvonne Norgett
- Department of Vision & Hearing Sciences, Anglia Ruskin University, Cambridge, UK
| | - Nancy Briggs
- Mark Wainwright Analytical Centre, University New South Wales, Sydney, Australia
| | - Peter M Allen
- Vision and Eye Research Unit, Anglia Ruskin University, Cambridge, UK
| | - Marta Vianya-Estopa
- Department of Vision & Hearing Sciences, Anglia Ruskin University, Cambridge, UK
| |
Collapse
|
13
|
Arroyo-Del Arroyo C, Novo-Diez A, Blanco-Vázquez M, Fernández I, López-Miguel A, González-García MJ. Does placebo effect exist in contact lens discomfort management? Cont Lens Anterior Eye 2020; 44:101370. [PMID: 33071184 DOI: 10.1016/j.clae.2020.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 09/18/2020] [Accepted: 09/28/2020] [Indexed: 11/26/2022]
Abstract
PURPOSE To study the effect of daily disposable contact lens (DDCL) refitting in monthly contact lens (CL) wearers suffering from contact lens discomfort (CLD), and to assess if there is a placebo effect associated with this CLD intervention. METHODS Symptomatic CL wearers, according to the Contact Lens Dry Eye Questionnaire 8 (CLDEQ-8 ≥ 12 points), were divided into two groups. The study group was provided with DDCLs (delefilcon A) and the control group with a masked pair of their habitual monthly CLs (placebo effect) and were assessed after one month. Then, the control group was provided with the same DDCLs and evaluated one month later. The symptoms were recorded with the CLDEQ-8 and global rating of change scale (GRCS). Non-invasive tear break-up time (NITBUT), conjunctival hyperaemia, fluorescein staining, and lid wiper epitheliopathy (LWE) were evaluated. Changes between visits, groups, and the effect of each intervention were analysed. RESULTS Thirty-one participants (mean age: 23.2 ± 5.3 years) were recruited. The study group (n = 14) showed an improvement of -39.6 ± 25.8 % (p < 0.001) in CLDEQ-8 and 31.3 ± 14.6 points in GRCS (p < 0.001) after one month of DDCL use, while no changes in clinical tests were found. In the control group (n = 17), symptoms improved significantly after wearing the masked monthly CL (CLDEQ-8: -26.1 ± 31.0 %, p = 0.03; GRCS: 14.9 ± 17.0, p = 0.002), however a worsening in bulbar (26.5 ± 40.0 %; p = 0.02) and limbal hyperaemia (21.6 ± 34.7 %, p = 0.02) and an improvement of -19.1 ± 37.0 % (p = 0.049) in LWE was found. When the control group was fitted with the DDCL, improvements in GRCS (20.5 ± 25.5, p = 0.02), NITBUT (37.9 ± 42.3 %, p = 0.002), and conjunctival staining (-47.1 ± 59.9 %, p = 0.005) were noted. CONCLUSIONS Refitting symptomatic monthly CL wearers with Delefilcon A DDCL is effective in reducing symptoms related to CLD. However, clinicians and researchers must be aware of the existence of a placebo effect when assessing the effectiveness of any CL refitting.
Collapse
Affiliation(s)
- Cristina Arroyo-Del Arroyo
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain; Departamento de Física Teórica, Atómica y Óptica, Universidad de Valladolid, Valladolid, Spain
| | - Andrea Novo-Diez
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain; Departamento de Física Teórica, Atómica y Óptica, Universidad de Valladolid, Valladolid, Spain
| | - Marta Blanco-Vázquez
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain
| | - Itziar Fernández
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain; Networking Research Center on Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| | - Alberto López-Miguel
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain; Redes temáticas de investigación cooperativa en salud (Oftared), Instituto de Salud Carlos III, Madrid, Spain.
| | - María Jesús González-García
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain; Departamento de Física Teórica, Atómica y Óptica, Universidad de Valladolid, Valladolid, Spain; Networking Research Center on Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| |
Collapse
|
14
|
Muntz A, Subbaraman LN, Craig JP, Jones L. Cytomorphological assessment of the lid margin in relation to symptoms, contact lens wear and lid wiper epitheliopathy. Ocul Surf 2020; 18:214-220. [DOI: 10.1016/j.jtos.2019.12.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Revised: 11/24/2019] [Accepted: 12/05/2019] [Indexed: 12/17/2022]
|
15
|
Abstract
OBJECTIVES To compare subjective and clinical outcomes in three study groups: (1) asymptomatic contact lens (CL) wearers (ASYM); (2) symptomatic CL wearers who become asymptomatic on lens removal; and (3) symptomatic CL wearers who do not resolve on lens removal. METHODS Ninety-two subjects completed the Berkeley Dry Eye Flow Chart with and without lenses, ocular surface examinations, and a battery of questionnaires. RESULTS Thirty-seven subjects (40%) were ASYM, 30 (33%) had contact lens-induced dry eye (CLIDE), and 25 (27%) had underlying physiological DE. Visual Analog Scale ratings, OSDI score, and SPEED score were significantly better for the ASYM group (P<0.001) but did not distinguish CLIDE from DE. The DE group was significantly worse than CLIDE and ASYM, which were similar, in precorneal noninvasive tear breakup time (8.2 sec DE vs. 12.3 sec CLIDE and 14.3 sec ASYM; P=0.002), anterior displacement of the Line of Marx (P=0.017), and superior conjunctival staining (P=0.001). CONCLUSIONS Many CL wearers presenting with dryness symptoms have an underlying DE condition and will not respond to treatments aimed at changing lenses or solutions. Contradictory results from research studies of DE in CL wearers could be due in part to a failure to distinguish subjects with symptoms due specifically to CL wear from those whose symptoms have underlying causes unrelated to CL wear.
Collapse
|
16
|
Guillon M, Maissa C, Wong S, Patel T, Garofalo R. The influence of lens care systems on eyelid tissue changes during silicone hydrogel contact lens wear. Cont Lens Anterior Eye 2018; 41:362-368. [DOI: 10.1016/j.clae.2018.02.141] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2017] [Revised: 02/28/2018] [Accepted: 02/28/2018] [Indexed: 10/17/2022]
|
17
|
Coles-Brennan C, Sulley A, Young G. Management of digital eye strain. Clin Exp Optom 2018; 102:18-29. [PMID: 29797453 DOI: 10.1111/cxo.12798] [Citation(s) in RCA: 98] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Revised: 03/26/2018] [Accepted: 04/20/2018] [Indexed: 02/01/2023] Open
Abstract
Digital eye strain, an emerging public health issue, is a condition characterised by visual disturbance and/or ocular discomfort related to the use of digital devices and resulting from a range of stresses on the ocular environment. This review aims to provide an overview of the extensive literature on digital eye strain research with particular reference to the clinical management of symptoms. As many as 90 per cent of digital device users experience symptoms of digital eye strain. Many studies suggest that the following factors are associated with digital eye strain: uncorrected refractive error (including presbyopia), accommodative and vergence anomalies, altered blinking pattern (reduced rate and incomplete blinking), excessive exposure to intense light, closer working distance, and smaller font size. Since a symptom may be caused by one or more factors, a holistic approach should be adopted. The following management strategies have been suggested: (i) appropriate correction of refractive error, including astigmatism and presbyopia; (ii) management of vergence anomalies, with the aim of inducing or leaving a small amount of heterophoria (~1.5Δ Exo); (iii) blinking exercise/training to maintain normal blinking pattern; (iv) use of lubricating eye drops (artificial tears) to help alleviate dry eye-related symptoms; (v) contact lenses with enhanced comfort, particularly at end-of-day and in challenging environments; (vi) prescription of colour filters in all vision correction options, especially blue light-absorbing filters; and (vii) management of accommodative anomalies. Prevention is the main strategy for management of digital eye strain, which involves: (i) ensuring an ergonomic work environment and practice (through patient education and the implementation of ergonomic workplace policies); and (ii) visual examination and eye care to treat visual disorders. Special consideration is needed for people at a high risk of digital eye strain, such as computer workers and contact lens wearers.
Collapse
Affiliation(s)
| | - Anna Sulley
- Vision Care Institute of Johnson and Johnson Medical Ltd, Wokingham, UK
| | | |
Collapse
|
18
|
Stahl U, Jalbert I. Exploring the links between contact lens comfort, osmolarity and lid wiper staining. Cont Lens Anterior Eye 2018; 41:110-116. [DOI: 10.1016/j.clae.2017.09.011] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2017] [Revised: 09/11/2017] [Accepted: 09/11/2017] [Indexed: 12/23/2022]
|
19
|
Huh J, Woo IH, Eom Y, Kang SY, Kim HM, Song JS. Lid Wiper Epitheliopathy in Patients with Dry Eye Refractory to Conventional Medical Treatment. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2018. [DOI: 10.3341/jkos.2018.59.8.718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Jungah Huh
- Department of Ophthalmology, Korea University College of Medicine, Seoul, Korea
| | - In Ho Woo
- Department of Ophthalmology, Korea University College of Medicine, Seoul, Korea
| | - Youngsub Eom
- Department of Ophthalmology, Korea University College of Medicine, Seoul, Korea
| | - Su-Yeon Kang
- Department of Ophthalmology, Korea University College of Medicine, Seoul, Korea
| | - Hyo Myung Kim
- Department of Ophthalmology, Korea University College of Medicine, Seoul, Korea
| | - Jong-Suk Song
- Department of Ophthalmology, Korea University College of Medicine, Seoul, Korea
| |
Collapse
|
20
|
|
21
|
Deng Z, Wang J, Jiang H, Fadli Z, Liu C, Tan J, Zhou J. Lid Wiper Microvascular Responses as an Indicator of Contact Lens Discomfort. Am J Ophthalmol 2016; 170:197-205. [PMID: 27542928 DOI: 10.1016/j.ajo.2016.08.009] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2016] [Revised: 08/04/2016] [Accepted: 08/05/2016] [Indexed: 01/15/2023]
Abstract
PURPOSE To analyze quantitatively the alterations in the microvascular network of the upper tarsal conjunctiva, lid wiper, and bulbar conjunctiva relative to ocular discomfort after contact lens wear. DESIGN A prospective, crossover clinical study. METHODS Functional slit-lamp biomicroscopy was used to image the microvascular network of the upper tarsal conjunctiva, lid wiper, and bulbar conjunctiva. The microvascular network was automatically segmented, and fractal analyses were performed to yield the fractal dimension (Dbox) that represented vessel density. Sixteen healthy subjects (9 female and 7 male) with an average age of 35.5 ± 6.7 years (mean ± standard deviation) were recruited. The right eye was imaged at 9 AM and 3 PM at the first visit (day 1) when the subject was not wearing contact lenses. During the second visit (day 2), the right eye was fitted with a contact lens for 6 hours. Microvascular imaging was performed before (at 9 AM) and after lens wear (at 3 PM). Ocular comfort was rated using a 50-point visual analog scale before and after 6 hours of lens wear, and its relationships with microvascular parameters were analyzed. RESULTS There were no significant differences in Dbox among the upper tarsal conjunctiva, lid wiper, and bulbar conjunctiva among the measurements at 9 AM (day 1 and day 2) and 3 PM (day 1) when the subjects were not wearing the lenses (P > .05), whereas after 6 hours of lens wear, the microvascular network densities were increased in all 3 of these locations. Dbox of the lid wiper increased from 1.411 ± 0.116 to 1.548 ± 0.079 after 6 hours of contact lens wear (P < .01). Dbox of the tarsal conjunctiva was 1.731 ± 0.026 at baseline and increased to 1.740 ± 0.030 (P < .05). Dbox of the bulbar conjunctiva increased from 1.587 ± 0.059 to 1.632 ± 0.060 (P < .001). The decrease in ocular discomfort was strongly related to the Dbox change in the lid wiper (r = 0.61, P < .05). There were no correlations between the changes of ocular comfort and the microvascular network densities of either the tarsal or bulbar conjunctivas (P > .05). CONCLUSIONS This study is the first to show that the microvascular network of the lid wiper can be quantitatively analyzed in contact lens wearers. The microvascular responses of the lid wiper were significantly correlated with contact lens discomfort.
Collapse
|
22
|
|