PURPOSE
The purpose of this study was to determine intrasession repeatability of a worksheet style contrast sensitivity test (SpotChecks) in children and agreement with an established contrast sensitivity test (Pelli-Robson).
METHODS
Forty-three children aged 4 to 12 years participated in this single visit study that included two administrations of the SpotChecks binocularly, a single administration of the Pelli-Robson test and other measures of visual performance such as high-contrast visual acuity. Test order was randomised, and participants wore their habitual correction (39 unaided, 4 wearing glasses) for testing. Bland-Altman plots were used to assess the test-retest repeatability of SpotChecks and its agreement with the Pelli-Robson test. Multiple linear regressions were performed to evaluate whether contrast sensitivity was related to participant characteristics such as age, sex and near binocular visual acuity.
RESULTS
The mean difference in log contrast sensitivity (logCS) between two administrations of the SpotChecks was 0.01, with a coefficient of repeatability (1.96*SD of differences) of 0.14 logCS. The mean difference between SpotChecks and Pelli-Robson was 0.00 logCS with 95% limits of agreement of -0.19 to +0.20. For both tests, a statistically significant increase in logCS was associated with age (slopes were 0.02 logCS/year, p < 0.001 and 0.01 logCS/year, p = 0.02 for the SpotChecks and Pelli-Robson tests, respectively).
CONCLUSIONS
The SpotChecks test shows good intrasession repeatability and excellent agreement with the Pelli-Robson test in children. Contrast sensitivity showed an increase in logCS with age in children for both tests.