1
|
Oruz O, Harbiyeli İİ, Erdem E, Yağmur M, Ateş EG. Attitudes and Behaviors Regarding Compliance With Contact Lens Wear and Care Among Contact Lens Users at a University Hospital in Turkey. Eye Contact Lens 2024; 50:426-431. [PMID: 39079078 DOI: 10.1097/icl.0000000000001116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/19/2024] [Indexed: 09/27/2024]
Abstract
OBJECTIVES To investigate the level of compliance with contact lens (CL) care habits among CL wearers of different age and occupation groups. METHODS This survey study included 205 CL wearers followed in the tertiary reference center between 2016 and 2022. The survey was employed to probe each user's demographic data and noncompliant behaviors. To this end, the study compared CL compliance levels of patients in different age and occupation groups. RESULTS There were 85 (41.5%) patients in the good compliant group, 72 (35.1%) in the average compliant group, and 48 (23.4%) in the poor compliant group. The most common noncompliant behavior was disruption of aftercare visits. Except for two noncompliant behaviors (storage of fresh lens solution and exceeding the recommended lens case replacement time), other noncompliant behaviors were found more frequently in the ≤25 age group. The differences between the age groups were significant in hand washing and water activities ( P =0.004 and P =0.023, respectively). Exceeding lens replacement time and sleeping with lenses criteria were found to be significantly noncompliant in health care workers compared to non-health care workers ( P =0.006 and P =0.001, respectively). The level of compliance was found to be lower in users with 6 to 7 days of CL use per week than in those with fewer days ( P =0.006). CONCLUSION We found that the compliance rate was lower in younger patients and health care workers. We also observed that long-term use of CL reduces the level of compliance. Therefore, it might be necessary to focus on modifiable risk factors in these patient groups.
Collapse
Affiliation(s)
- Oğuzhan Oruz
- Department of Ophthalmology (O.O.), Başkent University School of Medicine, Adana, Turkey; Department of Ophthalmology (İ.İ.H., E.E., M.Y.), Çukurova University School of Medicine, Adana, Turkey; and Middle East Technical University (E.G.A.), Institutional Big Data Management Coordination Office, Ankara, Turkey
| | | | | | | | | |
Collapse
|
2
|
Bajka A, Said S, Quiblier C, Schulthess B, Reinhold I, Barthelmes D, Zweifel SA, Blaser F. Long-Term Prevalence of Fungal Keratitis at a Swiss Tertiary Eye Clinic. Microorganisms 2024; 12:1637. [PMID: 39203477 PMCID: PMC11356936 DOI: 10.3390/microorganisms12081637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2024] [Revised: 08/06/2024] [Accepted: 08/08/2024] [Indexed: 09/03/2024] Open
Abstract
Fungal keratitis is a rare yet severe infection of the cornea. Fungal species distribution depends on the climate and socioeconomic status and can show regional variation. This retrospective single-center study was conducted at a tertiary eye care center and the collaborating Institute of Medical Microbiology in Switzerland. On investigating all fungal-positive corneal scrapings and contact lens assessments of patients with keratitis from January 2012 to December 2023, 206 patients were identified, of which 113 (54.9%) were female. The median age was 38 (IQR 29.8, [18-93]), and 154 (74.8%) applied contact lenses. The most commonly found pathogen was Candida spp., followed by Fusarium spp. Molds were 1.8 times more common than yeasts. Linear regression showed no significant increase or decrease in the infection rate over time (p = 0.5). In addition, 10 patients (4.9%) were found to have coinfections with Acanthamoeba, 11 (5.3%) with HSV-1, none with HSV-2, and 4 (1.9%) with VZV. This study provides a long-term overview of fungal-positive corneal scrapings and contact lens specimens of patients with fungal keratitis. Based on our results, coinfections with Acanthamoeba, HSV, and VZV are frequent, especially in patients wearing contact lenses. Thus, wearing contact lenses may facilitate coinfection in fungal keratitis.
Collapse
Affiliation(s)
- Anahita Bajka
- Department of Ophthalmology, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland; (A.B.)
| | - Sadiq Said
- Department of Ophthalmology, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland; (A.B.)
| | - Chantal Quiblier
- Institute of Medical Microbiology, University of Zurich, 8006 Zurich, Switzerland
| | - Bettina Schulthess
- Institute of Medical Microbiology, University of Zurich, 8006 Zurich, Switzerland
| | - Ilana Reinhold
- Department of Infectious Diseases and Hospital Epidemiology, University Hospital Zurich, 8091 Zurich, Switzerland
| | - Daniel Barthelmes
- Department of Ophthalmology, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland; (A.B.)
| | - Sandrine Anne Zweifel
- Department of Ophthalmology, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland; (A.B.)
| | - Frank Blaser
- Department of Ophthalmology, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland; (A.B.)
| |
Collapse
|
3
|
Kiani P, Soozanipour A, Rezayat A, Taheri-Kafrani A. Lysozyme-immobilized bandage contact lens inhibits the growth and biofilm formation of common eye pathogens in vitro. Exp Eye Res 2023; 234:109601. [PMID: 37488008 DOI: 10.1016/j.exer.2023.109601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 07/18/2023] [Accepted: 07/21/2023] [Indexed: 07/26/2023]
Abstract
Bandage contact lenses have an increased affinity to accumulate tear film proteins and bacteria during wear. Among the wide variety of tear film proteins, lysozyme has attracted the most attention for several reasons, including the fact that it is found at a high concentration in the tear film, has exceptional antibacterial and antibiofilm properties, and its significant deposits onto contact lenses. This study aims to evaluate the effect of lysozyme on bacterial biofilm formation on bandage contact lenses. For this purpose, several methods, including microtiter plate test and Colony Forming Unit (CFU) assay have been used to determine antibacterial and antibiofilm characteristics of lysozyme against the two most frequent contact lens-induced bacterial ocular infections, Staphylococcus aureus, and Pseudomonas aeruginosa. The results of these assays demonstrate lysozyme potential to inhibit 57.9% and 80.7% of the growth of S. aureus and P. aeruginosa, respectively. In addition, biofilm formations of P. aeruginosa and S. aureus reduced by 38.3% and 62.7%, respectively due to the antibiofilm effect of lysozyme. SEM and AFM imaging were utilized to visualize lysozyme antibacterial activity and topography changes of the contact lens surface, respectively, in the presence/absence of lysozyme. The results indicated that lysozyme can efficiently attack both gram-positive and gram-negative bacteria and consequently lysozyme-functionalized bandage contact lenses can reduce the risk of ocular infection after eye surgery.
Collapse
Affiliation(s)
- Pardis Kiani
- Department of Biotechnology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, 81746-73441, Iran
| | - Asieh Soozanipour
- Department of Biotechnology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, 81746-73441, Iran
| | - Azam Rezayat
- Department of Biotechnology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, 81746-73441, Iran; Department of Chemistry, Faculty of Science, Lorestan University, Khorramabad, Iran
| | - Asghar Taheri-Kafrani
- Department of Biotechnology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, 81746-73441, Iran.
| |
Collapse
|
4
|
de Azevedo Magalhães O, Ribeiro Dos Santos D, Coch Broetto BG, Corção G. Polyhexamethylene Biguanide Multipurpose Solutions on Bacterial Disinfection: A Comparison Study of Effectiveness in a Developing Country. Eye Contact Lens 2023; 49:139-142. [PMID: 36583857 DOI: 10.1097/icl.0000000000000967] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 11/23/2022] [Indexed: 12/31/2022]
Abstract
OBJECTIVE The aim of this study was to compare the antimicrobial action of commercially available multipurpose disinfection solutions (MPDS) with and without hydrogel contact lens for disinfection of isolated corneal bacteria. METHODS Five commercially available MPDS in Brazil (BioSoak, Clear Lens, OPTI-FREE, Renu, and UltraSept) were tested against Pseudomonas aeruginosa , Staphylococcus aureus , and Staphylococcus epidermidis . All five MPDS were also tested on P. aeruginosa and S. aureus biofilm in a Hioxifilcon A lens. RESULTS OPTI-FREE and Renu were effective against all bacterial isolates without contact lenses. BioSoak was effective in inhibiting P. aeruginosa and S. epidermidis but not against S. aureus . UltraSept was effective for inhibiting S. epidermidis and S. aureus but not against P. aeruginosa . Clear Lens was effective in inhibiting only S. epidermidis but not P. aeruginosa and S. aureus . In contact lens bacterial biofilms, OPTI-FREE was the only MPDS to demonstrate significantly higher disinfection. CONCLUSIONS MPDS containing dual biocides polyquaternium-1 and myristamidopropyl dimethylamine possess the highest disinfection action against multiple ocular pathogens with and without contact lenses when compared with other MPDS. Current single-action polyhexamethylene biguanide solutions are not entirely effective and should not be recommended.
Collapse
Affiliation(s)
- Otávio de Azevedo Magalhães
- Cornea and External Disease Division (O.A.M., B.G.C.B.), Hospital Banco de Olhos de Porto Alegre, Rio Grande do Sul, Brazil; and Department of Microbiology (D.R.S., G.S.), Immunology and Parasitology, Universidade Federal do Rio Grande do Sul, Brazil
| | | | | | | |
Collapse
|
5
|
Gammoh Y, Asfour W. Compliance to contact lens wear and care among Jordanian adults. PLoS One 2023; 18:e0280409. [PMID: 36630467 PMCID: PMC9833521 DOI: 10.1371/journal.pone.0280409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2022] [Accepted: 12/28/2022] [Indexed: 01/12/2023] Open
Abstract
OBJECTIVE To evaluate compliance to contact lens (CL) wear and care routines among adults in Jordan. DESIGN A cross-sectional study using a questionnaire administered by an interviewer was conducted among adults in Jordan between the months of May and July of the year 2022. PARTICIPANTS Adult (≥ 18 years) contact lens wearers attending work establishments, universities and shopping centers in the cities of Amman, Aqaba and Irbid in Jordan. MAIN OUTCOMES AND MEASURES Compliance to CL wear and care in addition to CL hygiene habits were evaluated. RESULTS A total of 834 (600 women) participants were included in the study with an age range of 18 to 55 years (average; 25.49 ± 7.75). Soft spherical CLs for myopia correction were worn by 45.6% of the sample, followed by cosmetic CLs (CCL) (43%). Highest compliance rate (99%) was calculated for not sharing CL with others and the lowest rate (24%) was for cleaning the CL case, with an average compliance rate of 72.25% for the sample with all habits surveyed. Medium compliance rates were related to following instructions of CL solution use including avoiding using expired solution or avoiding topping off. Risk factors for non-compliant behaviors included CCL wear, purchasing CL from beauty centers and being 25 years of age or younger. CONCLUSIONS AND RELEVANCE This study which was performed in a non-clinical setting showed that women and young adults comprise the majority of CL wearers in Jordan. Participants were compliant with most CL wear and care behaviors except for cleaning the CL case and attending aftercare visits. Many CL wearers also reported purchasing lenses from beauty centers and online without consulting CL practitioners. There is a need for patient education regarding the hygiene of the CL case, and the necessity for consulting the CL practitioner for the appropriate type of CL including proper wear and care regimen.
Collapse
Affiliation(s)
- Yazan Gammoh
- Faculty of Allied Medical Sciences, Department of Optometry Science, Al-Ahliyya Amman University, Amman, Jordan
- * E-mail:
| | - Wafa Asfour
- Faculty of Allied Medical Sciences, Department of Optometry Science, Al-Ahliyya Amman University, Amman, Jordan
| |
Collapse
|
6
|
Goble BJ, Boyd JD, Grady ME. Exploring microwave irradiation as a method to disinfect contact lens cases. Cont Lens Anterior Eye 2021; 45:101522. [PMID: 34642118 PMCID: PMC8993943 DOI: 10.1016/j.clae.2021.101522] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 08/24/2021] [Accepted: 09/28/2021] [Indexed: 11/24/2022]
Abstract
PURPOSE Biofilm formation caused by infrequent contact lens case replacement and the ineffectiveness of multi-purpose solutions (MPS) on biofilm removal is associated with high rates of bacterial keratitis infections. This study demonstrated biofilm elimination from the contact lens case by microwave irradiation. METHODS Staphylococcus aureus biofilms indicative of 3-9 months of contact wear were cultured in contact lens cases and visualized with crystal violet (CV) staining. Biofilms in contact cases were then exposed to four treatment regimens: No treatment (n = 8), 45 s microwave irradiation (n = 8), tap water (n = 6), and MPS (n = 9). Bacterial survival was assessed by colony forming unit (CFU) assay using streak dilutions. RESULTS Visualization of the biofilms through CV staining revealed that biofilms coalesce between ribs of the contact case. In 5/8 cases no CFU were cultivated from the case after treatment with microwave irradiation. In tap water and MPS the first dilution averaged 6 ± 2 and 31 ± 13 CFUs per plate, respectively, while microwave irradiation averaged < 1 CFU per plate. In Dilution 2, the average reduced to 0.7 ± 0.7 and 6 ± 5 CFUs per plate for tap water and MPS, respectively, while microwave irradiation had 0 CFUs in Dilution 2. CONCLUSION Biofilms that coalesce between the ribs of the contact case pose a threat because this area is difficult to thoroughly scrub and could act as a basis for infection through fouling of contact lenses. Of the four treatment regimens, microwave irradiation displayed the most consistent and highest rate of bacterial eradication. Tap water was less effective compared to microwave irradiation, and poses other harmful side effects, but greatly reduced CFU count compared to no treatment. MPS displayed the poorest bacterial eradication of the treatments. Thus, microwave irradiation is worth further investigation as a viable in-home disinfecting option.
Collapse
Affiliation(s)
- Brandon J Goble
- Agriculture and Medical Biotechnology, College of Agriculture, Food, and Environment, University of Kentucky, 506 Administration Drive, Lexington, KY 40506, United States; Department of Mechanical Engineering, College of Engineering, University of Kentucky, 506 Administration Drive, Lexington, KY, 40506, United States
| | - James D Boyd
- Department of Mechanical Engineering, College of Engineering, University of Kentucky, 506 Administration Drive, Lexington, KY, 40506, United States
| | - Martha E Grady
- Department of Mechanical Engineering, College of Engineering, University of Kentucky, 506 Administration Drive, Lexington, KY, 40506, United States.
| |
Collapse
|
7
|
Ilechie AA, Danquah D, Ntodie M, Andoh E, Addo NA, Odoi D, Otabil F, Assiamah F. Contact Lens- and Patient-related Factors Associated with Contact Lens Discomfort among Contact Lens Wearers in an African Cohort. Optom Vis Sci 2021; 98:1056-1062. [PMID: 34433206 DOI: 10.1097/opx.0000000000001765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
SIGNIFICANCE No information is available on contact lens discomfort in any African population. Such information may be helpful in developing the scope and priorities for intervention. PURPOSE The purpose of the study was to examine contact lens- and patient-related factors associated with contact lens discomfort among wearers in Ghana. METHODS In this multicenter cross-sectional study, contact lens wearers 18 years and older were recruited. The Contact Lens Dry Eye Questionnaire-8 and a standardized scripted interview were administered to 72 contact lens wearers at five clinical sites, and 40 participants' lens storage cases were collected and cultured. A variety of patient- and contact lens-related factors were examined. Univariate and multivariate logistic regression modeling were used to assess risk factors associated with contact lens discomfort. RESULTS Seventy-two contact lens wearers aged 18 to 45 years completed the study. The mean age was 27.5 ± 6.4 years, 65.3% of them were females, 86.1% wore soft contact lens, and 13.9% wore rigid gas-permeable lens. Contact lens discomfort was reported by 66.7% of the subjects. Most frequent lens storage cases isolates were Bacillus species (40%) and fungi (31.1%). Significant association was found between disinfecting with tap water (5.98; 95% confidence interval [CI], 1.22 to 29.27; P = .03), heavy visual display terminal use (3.39; 95% CI, 1.01 to 11.34; P = .05), high water content (1.16; 95% CI, 1.02 to 1.33; P = .03), and contact lens discomfort. Demographic factors, wear modality, and care solutions were not significant (all P > .05). CONCLUSIONS In considering the use of contact lenses for refractive correction in this population, strategies for preventing contact lens discomfort that should be targeted include use of low-water-content lenses, disinfecting with multipurpose solutions, and reducing the time spent daily on visual display terminal use.
Collapse
Affiliation(s)
- Alex Azuka Ilechie
- Department of Optometry and Vision Science, University of Cape Coast, Cape Coast, Ghana
| | | | - Michael Ntodie
- Department of Optometry and Vision Science, University of Cape Coast, Cape Coast, Ghana
| | - Ebenezer Andoh
- Effia Nkwanta Regional Hospital, Sekondi-Takoradi, Ghana
| | | | - Daniel Odoi
- St. Francis Xavier Hospital, Assin Fosu, Ghana
| | - Felix Otabil
- Weija-Gbawe Municipal Hospital, Greater Accra, Ghana
| | | |
Collapse
|
8
|
Arshad M, Carnt N, Tan J, Stapleton F. Effect of Water Exposure on Contact Lens Storage Case Contamination in Soft Lens Wearers. Optom Vis Sci 2021; 98:1002-1010. [PMID: 34570032 DOI: 10.1097/opx.0000000000001772] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE Water exposure during contact lens wear can transfer pathogenic microorganisms to the eye, causing ocular complications. This study determined that water exposure is prevalent among lens wearers and is independently associated with higher case contamination. Contact lens compliance education to minimize water exposure should be reenforced by contact lens organizations and practitioners. PURPOSE Given the increasing association between water exposure and contact lens disease, this study aimed to explore the effect of water exposure and storage case contamination in soft contact lens users. METHODS A total of 165 daily soft lens wearers completed a self-administered questionnaire on contact lens hygiene. Lens cases were collected, and microbial analysis was conducted using an adenosine triphosphate assay (for overall microbial bioburden) and limulus amebocyte lysate assay (for endotoxin levels). The lens hygiene (excellent, >35; moderate, 28 to 35; poor, <28) and water contact (≤1, good; >1, poor) scores measured the compliance and water exposure during lens wear, respectively. Multiple regression determined the association between water behaviors and case contamination. RESULTS The average (standard deviation) age of participants was 28 (13.5) years (18 to 78 years), and 65% were female. The average overall microbial bioburden of storage cases was 3.10 (0.98) log colony-forming unit/mL (1.09 to 5.94 log colony-forming unit/mL). Forty-five percent of participants reported showering, 49.7% reported swimming while wearing lenses (65.4% of whom swam without goggles), 27.8% used wet hands to handle lenses, and 17.5% used tap water to rinse storage cases. Showering with lenses significantly increased the risk of higher storage case bioburden (P = .001), whereas using wet hands (P = .01) doubled the risk of higher case endotoxin levels (odds ratio, 2.41; confidence interval 1.19 to 4.86). CONCLUSIONS Water contact behavior while wearing lenses is prevalent among soft lens wearers and is associated with higher case contamination. Practitioners may improve contact lens education to reduce water exposure and case contamination to reduce the risk of lens-related adverse events.
Collapse
Affiliation(s)
- Memoona Arshad
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Nicole Carnt
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Jacqueline Tan
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | | |
Collapse
|
9
|
Ung L, Chodosh J. Foundational concepts in the biology of bacterial keratitis. Exp Eye Res 2021; 209:108647. [PMID: 34097906 PMCID: PMC8595513 DOI: 10.1016/j.exer.2021.108647] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 04/28/2021] [Accepted: 05/27/2021] [Indexed: 12/12/2022]
Abstract
Bacterial infections of the cornea, or bacterial keratitis (BK), are notorious for causing rapidly fulminant disease and permanent vision loss, even among treated patients. In the last sixty years, dramatic upward trajectories in the frequency of BK have been observed internationally, driven in large part by the commercialization of hydrogel contact lenses in the late 1960s. Despite this worsening burden of disease, current evidence-based therapies for BK - including broad-spectrum topical antibiotics and, if indicated, topical corticosteroids - fail to salvage vision in a substantial proportion of affected patients. Amid growing concerns of rapidly diminishing antibiotic utility, there has been renewed interest in urgently needed novel treatments that may improve clinical outcomes on an individual and public health level. Bridging the translational gap in the care of BK requires the identification of new therapeutic targets and rational treatment design, but neither of these aims can be achieved without understanding the complex biological processes that determine how bacterial corneal infections arise, progress, and resolve. In this chapter, we synthesize the current wealth of human and animal experimental data that now inform our understanding of basic BK pathophysiology, in context with modern concepts in ocular immunology and microbiology. By identifying the key molecular determinants of clinical disease, we explore how novel treatments can be developed and translated into routine patient care.
Collapse
Affiliation(s)
- Lawson Ung
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA; Infectious Disease Institute, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA; Department of Epidemiology, Harvard T. H. Chan School of Public Health, Boston, MA, USA
| | - James Chodosh
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA; Infectious Disease Institute, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
10
|
Nakagawa M, Nakagawa R, Willcox MDP, Vijay AK. Effect of Hygiene Procedures on Lens Case Contamination with Povidone-Iodine or Multipurpose Disinfecting Solutions. Optom Vis Sci 2021; 98:563-569. [PMID: 34039910 DOI: 10.1097/opx.0000000000001700] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
SIGNIFICANCE A multipurpose disinfecting solution (MPDS), which contains povidone-iodine (PI) as a disinfectant, has high disinfecting efficacy not only on planktonic bacterium but also on the case biofilms. The addition of case hygiene practice removed more bacteria from cases than MPDS alone. PURPOSE This study compared the ability of two MPDSs, one containing PI and another containing polyaminopropyl biguanide and polyquaternium, to reduce bacterial numbers in solution or adhered to the cases following case hygiene procedures. METHODS Bacterial strains (Delftia acidovorans, Pseudomonas aeruginosa, Stenotrophomonas maltophilia, Serratia marcescens, Staphylococcus aureus, and Staphylococcus epidermidis) were exposed to the MPDSs for the recommended disinfection times, and the viable number evaluated according to ISO 14729. Cases were inoculated with bacterial strains and incubated for 24 hours to allow for biofilm formation. Cases were disinfected with both disinfecting solutions for 4 hours and rinsed, followed by recapping or air-drying, or tissue-wiping and air-drying for 18 hours. The number of survivors was counted using standard culture techniques. RESULTS Both products exceeded the recommended 3-log reduction against planktonic bacteria. Regarding biofilm, after rinsing and recapping wet, the numbers of D. acidovorans (mean difference [95% confidence interval] log10 colony-forming units per case, -2.9 [0.8 to -4.6], P < .01), P. aeruginosa (-2.0 [0.5 to -3.1], P < .01), S. marcescens (-1.7 [0.8 to -3.5], P < .05), and S. epidermidis (-2.1 [0.6 to -3.5], P < .05) in PI cases were significantly lower than in the dual-disinfectant MPDS storage cases. After air-drying, the PI storage cases had significantly lower numbers of S. maltophilia (-2.6 [0.6 to -4.0], P < .01), D. acidovorans (-1.6 [0.7 to -3.3], P < .05), and S. aureus (-1.6 [0.7 to -3.1], P < .05). The addition of tissue-wiping reduced the bacterial numbers in the MPDS storage cases to levels in the PI storage cases. CONCLUSIONS Contact lens users should be recommended to tissue-wipe and air-dry their lens storage cases after disinfection with regular MPDS.
Collapse
Affiliation(s)
| | | | - Mark D P Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Ajay Kumar Vijay
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| |
Collapse
|
11
|
Gammoh Y, Abdu M. Contact lens procurement and usage habits among adults in Sudan. PLoS One 2021; 16:e0251987. [PMID: 34010356 PMCID: PMC8133405 DOI: 10.1371/journal.pone.0251987] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Accepted: 05/06/2021] [Indexed: 02/03/2023] Open
Abstract
Objective The study aimed to assess contact lens (CL) wear and care habits among adults in Sudan. Design An observational, non-interventional, multi-center, cross-sectional study was conducted in the CL departments of all the eye hospitals and centers, and optical centers in the Khartoum State, Sudan. Participants Established CL wearers residing in Khartoum State, Sudan. Main outcomes and measures CL wear profile, CL usage habits, hand and CL hygiene habits were assessed using an interviewer-administered questionnaire. Results The average age of the 442 participants was 24.57 (± 4.87) years. Women comprised 92% of the sample. Smoking was reported by 15.8% of the sample. 81.9% wore soft spherical CL, with 43.4% of the participants were prescribed CL on a yearly replacement schedule. Only 68.3% were prescribed CL by an eye care practitioner. Multipurpose solutions were used by 78.8% of the sample to clean CL, and by 52% to clean the lens case. Compliance rate for CL wear and care among participants was 81.1%. None of the participants reported sharing CL or CL case and rinsing the case with tap water. High compliance level was observed for overnight wear; swimming and showering with CL; handwashing before CL insertion; and cleaning of CL. Moderate compliance rates were recorded for cleaning and replacing lens case, and topping up or sharing solution. Low compliance was noted for attending after care visits. Conclusions and relevance CL wearers in Sudan exhibit high to moderate levels of compliance to most contact lens wear and care aspects, except for attending aftercare visits. CL practitioners in Sudan are encouraged to prescribe CL appropriate to the lifestyle and economic situation of patients and actively recommend care products. In addition, practitioners need to follow up with patients to attend aftercare appointments, where hygienic wear and care habits should be emphasized.
Collapse
Affiliation(s)
- Yazan Gammoh
- Faculty of Allied Medical Sciences, Department of Optometry Science, Al-Ahliyya Amman University, Amman, Jordan
- * E-mail:
| | - Mustafa Abdu
- Faculty of Optometry and Visual Sciences, Department of Contact Lenses, Al-Neelain University, Khartoum, Sudan
- Faculty of Applied Medical Sciences, Department of Optometry, University of Jeddah, Jeddah, KSA
| |
Collapse
|
12
|
Stapleton F. Contact lens‐related corneal infection in Australia. Clin Exp Optom 2021; 103:408-417. [DOI: 10.1111/cxo.13082] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Accepted: 03/31/2020] [Indexed: 12/20/2022] Open
Affiliation(s)
- Fiona Stapleton
- School of Optometry and Vision Science, The University of New South Wales, Sydney, Australia,
| |
Collapse
|
13
|
Steele KR, Wagner H, Lai N, Zimmerman AB. Gas-Permeable Contact Lenses and Water Exposure: Practices and Perceptions. Optom Vis Sci 2021; 98:258-265. [PMID: 33771955 DOI: 10.1097/opx.0000000000001660] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE This study provides insight into the current recommendations, clinical behaviors, and risk assessments of eye care professionals on the topic of rigid contact lens exposure to tap water. This knowledge may motivate professional organizations to develop initiatives to educate eye care professionals on the dangers of contact lens exposure to water. PURPOSE The purpose of this study was to investigate the practice patterns and risk perceptions of eye care professionals regarding gas-permeable contact lens exposure to tap water. METHODS A branched-logic survey was started by 320 clinicians, vision scientists, and industry personnel and was fully completed by 272 participants. The survey queried participants about their current practices, recommendations, and perceptions of risk regarding exposure of gas-permeable contact lenses to tap water. RESULTS Of those who prescribe gas-permeable contact lenses, 57.4% reported rinsing lenses with tap water, whereas only 32.7% reported engaging in this same behavior in front of patients. Of those who reported never rinsing lenses with tap water, 85.6% indicated that rinsing lenses with water increases infection risk, whereas 52.1% of those who rinse lenses with water reported the same perceived risk (P < .001). Of all participants, 60% indicated that wearing contact lenses while showering increases infection risk, and 50.2% of all participants advised patients to avoid this behavior. CONCLUSIONS A discrepancy exists between perceptions of risk concerning exposure of contact lenses to water and both clinical practices and patient education provided by professionals.
Collapse
Affiliation(s)
| | - Heidi Wagner
- The Ohio State University, College of Optometry, Columbus, Ohio
| | - Nicky Lai
- The Ohio State University, College of Optometry, Columbus, Ohio
| | | |
Collapse
|
14
|
Yamasaki K, Mizuno Y, Kitamura Y, McCanna DJ, Ngo W, Jones LW. The efficacy of povidone-iodine, hydrogen peroxide and a chemical multipurpose contact lens care system against Pseudomonas aeruginosa on various lens case surfaces. Cont Lens Anterior Eye 2021; 44:18-23. [DOI: 10.1016/j.clae.2020.02.012] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 02/18/2020] [Accepted: 02/20/2020] [Indexed: 10/24/2022]
|
15
|
Hotta F, Eguchi H, Nakayama-Imaohji H, Kuwahara T, Tada A, Yagi H, Shimomura Y, Kusaka S. Microbiome analysis of contact lens care solutions and tear fluids of contact lens wearers: Possible involvement of streptococcal antigens in allergic symptoms related to contact lens wear. Int J Mol Med 2020; 46:1367-1376. [PMID: 32945368 PMCID: PMC7447315 DOI: 10.3892/ijmm.2020.4678] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Accepted: 06/24/2020] [Indexed: 12/25/2022] Open
Abstract
The present study elucidated the pathogenesis of allergic symptoms (AS) related to contact lens (CL) wear by assaying CL care solutions in lens storage cases and tears from subjects with AS using molecular biology techniques. A total of 15 CL storage cases were collected from subjects with AS (n=9) and healthy, asymptomatic control CL wearers (n=6). Bacterial populations in CL care solutions and tears were assayed by culture and 16S rDNA sequencing. Histamine levels in tears were measured by high-performance liquid chromatography. Western blot analysis was performed to identify the bacteria recognized by tear IgE from subjects with AS. No significant differences were found in the culture results between the subjects with AS and asymptomatic subjects. Histamine was detected in 2 subjects with AS. Meta-16S rDNA sequencing identified a cluster of 4 subjects with AS that were distinguished from others by principal coordinate analysis. Detailed population analysis revealed that the abundance of Gram-positive bacteria in the microbiomes of CL care solutions used by the subjects with AS were higher than those of asymptomatic subjects (42.24±9.47 vs. 16.85±22.76% abundance). Among these, Streptococcus was the dominant genus (12.1-18.3% abundance). Tear microbiome analysis revealed that the abundance of Streptococcus in the subjects with AS was significantly higher than that in other subjects (19.02±5.50 vs. 3.08±3.35%, P<0.01). Western blot analysis demonstrated that the tear IgE in all subjects with AS reacted with Streptococcus (100%), but not with Staphylococcus. On the whole, these results provide novel insight into the pathogenesis of AS and identify Streptococcus as an important factor in AS associated with CL wear.
Collapse
Affiliation(s)
- Fumika Hotta
- Department of Ophthalmology, Kindai University Faculty of Medicine, Osakasayama, Osaka 589‑8511, Japan
| | - Hiroshi Eguchi
- Department of Ophthalmology, Kindai University Faculty of Medicine, Osakasayama, Osaka 589‑8511, Japan
| | | | - Tomomi Kuwahara
- Department of Microbiology, Faculty of Medicine, Kagawa University, Miki, Kagawa 761‑0793, Japan
| | - Ayano Tada
- Department of Microbiology, Faculty of Medicine, Kagawa University, Miki, Kagawa 761‑0793, Japan
| | - Hirofumi Yagi
- Department of Microbiology, Faculty of Medicine, Kagawa University, Miki, Kagawa 761‑0793, Japan
| | | | - Shunji Kusaka
- Department of Ophthalmology, Kindai University Faculty of Medicine, Osakasayama, Osaka 589‑8511, Japan
| |
Collapse
|
16
|
Datta A, Willcox MDP, Stapleton F. In vivo efficacy of silver-impregnated barrel contact lens storage cases. Cont Lens Anterior Eye 2020; 44:101357. [PMID: 32807659 DOI: 10.1016/j.clae.2020.08.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Revised: 08/02/2020] [Accepted: 08/06/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE This study examined the rate and level of microbial contamination of silver and non-silver (control) barrel contact lens storage cases in vivo. METHODS A prospective, single-centre, randomized, double blinded, crossover study was conducted to evaluate the efficacy of silver and control barrel cases used with an Oxipol™-based disinfecting solution over a two-month period. Lens cases were collected, and the frequency, type and level of microbial contamination evaluated using viable culture and standard identification methods. Questionnaires were used to assess the contact lens-related hygiene compliance of the participants. RESULTS Forty eight daily contact lens wearers completed the study. Overall, 27 % of silver and 35 % control lens cases (P > 0.05) were contaminated, predominantly with Gram-positive bacteria. Only, 12 % of participants had good compliance, with 46 % having average compliance and 43 % poor compliance. Compliance score was not associated with level of microbial contamination. However, the use of hydrogel lenses in combination with silver cases compared to non-silver barrel cases resulted significantly greater numbers of bacteria colonising cases. CONCLUSION The present investigation demonstrated that the use of silver barrel cases does not reduce the overall rate and level of bacterial contamination, but that using hydrogel lenses in combination with silver cases resulted in higher numbers of bacteria isolated from cases.
Collapse
Affiliation(s)
- Ananya Datta
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Mark D P Willcox
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia.
| |
Collapse
|
17
|
Bacterial biofilm in silver-impregnated contact lens cases. Cont Lens Anterior Eye 2020; 43:408-412. [DOI: 10.1016/j.clae.2019.11.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2019] [Revised: 11/11/2019] [Accepted: 11/11/2019] [Indexed: 11/19/2022]
|
18
|
Wong K, Flanagan J, Jalbert I, Tan J. The effect of Blephadex™ Eyelid Wipes on Demodex mites, ocular microbiota, bacterial lipase and comfort: a pilot study. Cont Lens Anterior Eye 2019; 42:652-657. [DOI: 10.1016/j.clae.2019.06.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Revised: 05/24/2019] [Accepted: 06/11/2019] [Indexed: 10/26/2022]
|
19
|
Hu X, Shi G, Liu H, Jiang X, Deng J, Zhu C, Yuan Y, Ke B. Microbial Contamination of Rigid Gas Permeable (RGP) Trial Lenses and Lens Cases in China. Curr Eye Res 2019; 45:550-555. [PMID: 31697186 DOI: 10.1080/02713683.2019.1687726] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Purpose: This study aimed to evaluate the microbial contamination level and its influencing factors of rigid gas permeable (RGP) trial lenses and lens cases in China.Materials and Methods: A total of 107 RGP trial lenses and lens cases were collected from 7 main hospitals or optometric centers in China. Three sites including the lenses, case interiors and case screw tops were sampled for bacterial and fungal culture and identification. The contamination rates of these three sites and their relationship with lens care regimes were further analyzed.Results: The overall contamination rate was 73.8% for either lenses or cases, and 43.0% of lenses, 57.0% of case interiors and 65.4% of case screw tops respectively. The most frequently isolated microorganisms were Serratia spp., Burkholderia spp., Pandoraea spp., and Achromobacter spp. from all three sites. The contamination rate was positively related to the lens use frequency. Compared with dry-stored lenses, the contamination rate was significantly higher in wet-stored group (P < .001*). Inadequate disinfection and improper lens and case care regimes were also associated with higher contamination rates.Conclusions: Our study reported that the RGP trial lenses and cases used for fittings had a considerably high contamination rate. The safe use of RGP trial lenses and education of optometrists on the regular maintenance of trial lenses should be emphasized.
Collapse
Affiliation(s)
- Xiaojun Hu
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Fundus Disease, Shanghai Jiaotong University, Shanghai, China.,Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai Jiaotong University, Shanghai, China
| | - Guangsen Shi
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Fundus Disease, Shanghai Jiaotong University, Shanghai, China.,Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai Jiaotong University, Shanghai, China
| | - Hong Liu
- Department of Laboratory Medicine, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai, China
| | - Xiaofei Jiang
- Department of Laboratory Medicine, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai, China
| | - Jiaojiao Deng
- Itabashi Medical (Dalian) Co., Ltd., Dalian, Liaoning Province, China
| | - Chengcheng Zhu
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Fundus Disease, Shanghai Jiaotong University, Shanghai, China.,Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai Jiaotong University, Shanghai, China
| | - Ying Yuan
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Fundus Disease, Shanghai Jiaotong University, Shanghai, China.,Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai Jiaotong University, Shanghai, China
| | - Bilian Ke
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Fundus Disease, Shanghai Jiaotong University, Shanghai, China.,Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai Jiaotong University, Shanghai, China
| |
Collapse
|
20
|
Datta A, Willcox M, Stapleton F. In Vitro Antimicrobial Efficacy of Silver Lens Cases Used With a Multipurpose Disinfecting Solution. Transl Vis Sci Technol 2019; 8:52. [PMID: 31293807 PMCID: PMC6601708 DOI: 10.1167/tvst.8.3.52] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Accepted: 04/19/2019] [Indexed: 11/24/2022] Open
Abstract
Purpose We evaluate the in vitro antibacterial activity of silver-copolymerized barrel cases compared to nonsilver barrel cases in combination with a multipurpose disinfecting solution (MPDS). Methods The ability of silver and nonsilver cases to reduce the number of adherent Gram-positive and Gram-negative bacteria was assessed. Additionally, the efficacy of silver cases along with MPDS was investigated in the presence of organic soil and contact lenses. Contact lens cases were challenged with 106 colony-forming units (CFU)/mL of five bacterial species. Adherent bacteria were dislodged from lens cases and surviving organisms enumerated. Results Significantly lower numbers of microbes were recovered from silver cases compared to controls, for all bacterial strains (P < 0.005). The combination of silver case along with MPDS showed added efficacy against Gram-positive and -negative bacteria with a maximum reduction of 3.00 ± 0.5 Log10 CFU/mL, compared to the efficacy of silver cases alone (1.97 ± 0.4 Log10 CFU/mL). The addition of organic soil and a contact lens resulted in a significant (P < 0.005) decrease (a maximum of 1.68 ± 0.2 log10 CFU/mL) in disinfection efficacy when MPDS and either silver or control cases were used. Conclusions Silver-copolymerized barrel cases work on conjunction with a hypochlorite producing MPDS in the presence of contact lenses and organic soil to reduce microbial contamination of lens cases. Transitional Relevance Silver-copolymerized barrel contact lens cases show promising in vitro antibacterial activity against bacterial types commonly implicated in contact lens-related corneal infections. This intervention may limit storage case contamination during use and reduce the frequency of contact lens-related microbial disease.
Collapse
Affiliation(s)
- Ananya Datta
- School of Optometry and Vision Science, University of New South Wales Sydney, Australia
| | - Mark Willcox
- School of Optometry and Vision Science, University of New South Wales Sydney, Australia
| | - Fiona Stapleton
- School of Optometry and Vision Science, University of New South Wales Sydney, Australia
| |
Collapse
|
21
|
Pucker AD, Jones-Jordan LA, Marx S, Powell DR, Kwan JT, Srinivasan S, Sickenberger W, Jones L. Clinical factors associated with contact lens dropout. Cont Lens Anterior Eye 2019; 42:318-324. [DOI: 10.1016/j.clae.2018.12.002] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2018] [Revised: 10/19/2018] [Accepted: 12/01/2018] [Indexed: 02/01/2023]
|
22
|
Abstract
The purpose of this article is to provide a review of existing literature describing complications with contemporary contact lenses and their management. It is envisioned that this will serve as a useful summary of noninfectious and infectious complications associated with contact lens wear.
Collapse
|
23
|
Adhesion of Stenotrophomonas maltophilia, Delftia acidovorans, and Achromobacter xylosoxidans to Contact Lenses. Eye Contact Lens 2018; 44 Suppl 2:S120-S126. [DOI: 10.1097/icl.0000000000000425] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
24
|
Datta A, Stapleton F, Willcox MDP. Bacterial Coaggregation and Cohesion Among Isolates From Contact Lens Cases. Invest Ophthalmol Vis Sci 2018; 59:2729-2735. [PMID: 29860459 DOI: 10.1167/iovs.17-23155] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose The aim of this study was to examine cohesion, coaggregation, and coculture between bacteria commonly isolated from contact lens cases. Methods Staphylococcus epidermidis, Staphylococcus haemolyticus, Micrococcus luteus, and Acinetobacter radioresistens (two strains each) isolated from contact lens cases of two asymptomatic wearers were used in this study. In the cohesion assay, bacteria were grown, washed, and examined by incubating lens cases with two different types of bacteria sequentially and assessing the number of adhered cells of each isolate. The ability of isolates to interfere with the growth of other isolates was tested by growing strains in cocultures for 24 hours and determining the numbers of cells of individual strains. For coaggregation, equal proportions of two bacterial suspensions were mixed and allowed to coaggregate for 24 hours. Inhibition of coaggregation was tested by the addition of lactose (0.06 M) or sucrose (0.06 M) or pronase. Results The initial adhesion of M. luteus or A. radioresistens significantly (P < 0.05) enhanced the subsequent adhesion of the staphylococci. The addition of A. radioresistens in liquid media significantly (P < 0.05) enhanced the growth of staphylococci. S. epidermidis or S. haemolyticus coaggregated with M. luteus or A. radioresistens. The degree of coaggregation varied between 30% and 54%. The highest coaggregation (54% ± 5%) was seen between A. radioresistens 22-1 and S. epidermidis 22-1, isolated from the same lens case. Only lactose or sucrose treatment of staphylococci could partly inhibit coaggregation of some pairs. Conclusions Coaggregation, cohesion, and growth promotion may facilitate the process of bacterial colonization of contact lens cases.
Collapse
Affiliation(s)
- Ananya Datta
- School of Optometry and Vision Science, University of New South Wales Sydney, New South Wales, Australia
| | - Fiona Stapleton
- School of Optometry and Vision Science, University of New South Wales Sydney, New South Wales, Australia
| | - Mark D P Willcox
- School of Optometry and Vision Science, University of New South Wales Sydney, New South Wales, Australia
| |
Collapse
|
25
|
In Vitro Effect of Lysozyme on Albumin Deposition to Hydrogel Contact Lens Materials. Optom Vis Sci 2017; 94:1047-1051. [PMID: 29040199 DOI: 10.1097/opx.0000000000001137] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
SIGNIFICANCE Albumin deposition on contact lenses could be detrimental to contact lens (CL) wear because this may increase the risk of bacterial binding and reduce comfort. Lysozyme deposition on selected lens materials would reduce albumin deposition on lenses. PURPOSE This study aims to determine if lysozyme deposition on CLs could act as a barrier against subsequent albumin adsorption, using an in vitro model. METHODS Six hydrogel CL materials (etafilcon A, polymacon, nelfilcon A, omafilcon A, ocufilcon B, and nesofilcon A) were evaluated. Four CLs of each type were soaked in lysozyme solution for 16 hours at 37°C. Lysozyme-coated lenses were then placed in vials with 1.5 mL of artificial tear solution containing I-labeled albumin for 16 hours at 37°C with shaking. Four uncoated lenses of each type were used as controls. Lenses soaked in radiolabeled albumin were rinsed in a phosphate-buffered saline solution, and radioactive counts were measured directly on lenses using a gamma counter. Albumin uptake on lenses was measured using a calibration curve by plotting radioactive counts versus protein concentration. RESULTS Results are reported as mean ± SD. Lysozyme-coated etafilcon A lenses exhibited lower levels of deposited albumin than uncoated etafilcon A lenses (58 ± 12 vs. 84 ± 5 ng/lens; P < .05). There were no differences in albumin adsorption between control (uncoated) and lysozyme-coated polymacon (105 ± 10 vs. 110 ± 34 ng/lens), nelfilcon A (51 ± 7 vs. 42 ± 20 ng/lens), omafilcon A (90 ± 20 vs. 80 ± 38 ng/lens), ocufilcon B (87 ± 20 vs. 115 ± 50 ng/lens), and nesofilcon A (170 ± 29 vs. 161 ± 10 ng/lens) lens materials (P > .05). Uncoated nesofilcon A lenses deposited the highest amount of albumin when compared with other uncoated lenses (P < .05). CONCLUSIONS This study demonstrates that lysozyme deposited onto etafilcon A resists the deposition of albumin, which may potentially be beneficial to CL wearers.
Collapse
|
26
|
Steele KR, Szczotka-Flynn L. Epidemiology of contact lens-induced infiltrates: an updated review. Clin Exp Optom 2017; 100:473-481. [PMID: 28868803 DOI: 10.1111/cxo.12598] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2017] [Revised: 07/10/2017] [Accepted: 07/11/2017] [Indexed: 11/29/2022] Open
Abstract
Corneal infiltrative events (CIEs) are well established as a risk associated with soft contact lens wear. The incidence of symptomatic CIEs during extended soft lens wear ranges from 2.5 to six per cent; when asymptomatic CIEs are included, the incidence can be as high as 20-25 per cent. In daily soft lens wear, the annual incidence of symptomatic CIEs is about three per cent. There are various accepted methods of categorising CIEs, and a scoring system based on clinical signs and symptoms is a good approach to grade severity. Lens-related risk factors include extended wear, silicone hydrogel material, the use of multipurpose solutions, bacterial bioburden and reusable lenses. Recent studies report that daily disposable lenses reduce the risk of CIEs.
Collapse
Affiliation(s)
- Kelsy R Steele
- The Ohio State University College of Optometry, Columbus, Ohio, USA
| | - Loretta Szczotka-Flynn
- University Hospitals Eye Institute, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA.,Department of Ophthalmology and Visual Sciences, Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
27
|
Temporal Stability and Composition of the Ocular Surface Microbiome. Sci Rep 2017; 7:9880. [PMID: 28852195 PMCID: PMC5575025 DOI: 10.1038/s41598-017-10494-9] [Citation(s) in RCA: 146] [Impact Index Per Article: 20.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2017] [Accepted: 08/10/2017] [Indexed: 02/03/2023] Open
Abstract
To determine if there is a core ocular surface microbiome and whether there are microbial community changes over time, the conjunctiva of 45 healthy subjects were sampled at three time points over three months and processed using culture-dependent and -independent methods. Contaminant taxa were removed using a linear regression model using taxa abundances in negative controls as predictor of taxa abundances in subject samples. Both cultured cell counts and sequencing indicated low microbial biomass on the ocular surface. No cultured species was found in all subjects at all times or in all subjects at any one time. After removal of contaminant taxa identified in negative controls using a statistical model, the most commonly detected taxon was Corynebacterium (11.1%). No taxa were found in all subjects at all times or in all subjects in any one time, but there were 26 taxa present in at least one or more subjects at all times including Corynebacterium and Streptococcus. The ocular surface contains a low diversity of microorganisms. Using culture dependent and independent methods, the ocular surface does not appear to support a substantial core microbiome. However, consistently present taxa could be observed within individuals suggesting the possibility of individual-specific core microbiomes.
Collapse
|
28
|
Hinojosa JA, Patel NB, Zhu M, Robertson DM. Antimicrobial Efficacy of Contact Lens Care Solutions Against Neutrophil-Enhanced Bacterial Biofilms. Transl Vis Sci Technol 2017; 6:11. [PMID: 28473944 PMCID: PMC5412968 DOI: 10.1167/tvst.6.2.11] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Accepted: 02/21/2017] [Indexed: 12/28/2022] Open
Abstract
Purpose Neutrophil-derived extracellular debris has been shown to accelerate bacterial biofilm formation on hydrogel and silicone hydrogel contact lens surfaces compared to lenses inoculated with bacteria alone. The purpose of this study was to evaluate the disinfection efficacy of four standard commercial contact lens cleaning regimens against neutrophil-enhanced bacterial biofilms formed on silicone hydrogel contact lenses. Methods Four reference strains were used: Pseudomonas aeruginosa,Serratia marcescens,Stenotrophomonas maltophilia, and Staphylococcus aureus. Human neutrophils were isolated from peripheral blood by venipuncture. Unworn Lotrafilcon B lenses were incubated overnight in each respective strain with stimulated neutrophils. Contact lenses were then cleaned using one of four contact lens care solutions according to manufacturer instructions. Bacterial viability was assessed by colony counts and confocal microscopy. Volume of residual debris on lens surfaces after cleaning was quantified using IMARIS software. Results All four solutions tested showed effective antimicrobial activity against each bacterial strain; however, substantial amounts of nonviable bacteria and cellular debris remained on the lens surface despite concomitant digital cleaning. Conclusions Necrotic cellular debris that accumulates under the posterior lens surface during wear of an inoculated contact lens is not fully removed during routine cleaning and disinfection. Translational Relevance The accumulation of residual cellular debris on the contact lens surface may contribute to new colonization of the lens and represents a significant risk factor for a contact lens–related adverse event. Additional studies are needed to correlate these findings with risk for corneal infiltrative and/or infectious events in a standard animal model.
Collapse
Affiliation(s)
- Jorge A Hinojosa
- Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Naiya B Patel
- Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Meifang Zhu
- Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Danielle M Robertson
- Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
29
|
|
30
|
Assessment of biofilm formation of E. meningoseptica, D. acidovorans, and S. maltophilia in lens cases and their growth on recovery media. Cont Lens Anterior Eye 2016; 39:117-23. [DOI: 10.1016/j.clae.2015.09.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2015] [Revised: 08/12/2015] [Accepted: 09/01/2015] [Indexed: 11/20/2022]
|
31
|
Lo J, Fang PC, Chien CC, Hsiao CC, Tseng SL, Lai YH, Kuo MT. PCR analysis for assessment of bacterial bioburden in orthokeratology lens cases. Mol Vis 2016; 22:1-8. [PMID: 26900321 PMCID: PMC4734148 DOI: pmid/26900321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2015] [Accepted: 01/12/2016] [Indexed: 02/08/2023] Open
Abstract
PURPOSE To develop a PCR gel analysis method for assessing the bacterial bioburden in orthokeratology contact lens (OK) case fluid determined by culture. METHODS A prospective study with the participation of 41 OK wearers (20 girls, 21 boys) was performed. The mean OK-wearing experience was 3.5±1.9 years. PCR was used to assess the bacterial bioburden (colony-forming units per milliliter) of OK after removal and soaking in the storage case for 6 h. The signal intensity of the PCR bands was analyzed after grayscale image transformation. The difference (cPCR-d) and ratio (cPCR-r) between a PCR signal and its background were used as two standardized indices of PCR signals. The association between the two indices of the PCR signals and the bacterial bioburden determined by culture were analyzed with Pearson's correlation coefficient (r) and receiver operating characteristic (ROC) plots. RESULTS At least one microbe was isolated from the OK lens case from 38 of the 41 subjects. Both cPCR-d and cPCR-r showed strong correlations with the bacterial bioburden (r>0.7, p<0.0001). ROC analysis enabled good determination of the cutoff values for the two PCR indices with acceptable sensitivity and specificity (78-89%) to assess the degree of bacterial contamination. CONCLUSIONS The high microbial contamination rate of the OK lens cases revealed the general inappropriate lens care by OK wearers. PCR analysis provides an alternative and rapid method for assessing the bacterial bioburden of OK lens cases, and these results should serve as a warning to OK wearers to follow appropriate lens care procedures to prevent infection.
Collapse
Affiliation(s)
- Jung Lo
- Department of Ophthalmology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Po-Chiung Fang
- Department of Ophthalmology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Chun-Chih Chien
- Department of Laboratory Medicine, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Chang-Chun Hsiao
- Graduate Institute of Clinical Medical Sciences, Chang Gung University, Taiwan
| | - Shin-Ling Tseng
- Department of Ophthalmology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Yu-Hsuan Lai
- Department of Ophthalmology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Ming-Tse Kuo
- Department of Ophthalmology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| |
Collapse
|
32
|
Zimmerman AB, Emch AJ, Geldis J, Nixon GJ, Mitchell GL. Contact Lens Corneal Inflammatory Events in a University Population. Optom Vis Sci 2016; 93:42-9. [DOI: 10.1097/opx.0000000000000746] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
33
|
|
34
|
Wu YTY, Willcox M, Zhu H, Stapleton F. Contact lens hygiene compliance and lens case contamination: A review. Cont Lens Anterior Eye 2015; 38:307-16. [DOI: 10.1016/j.clae.2015.04.007] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2014] [Revised: 04/15/2015] [Accepted: 04/21/2015] [Indexed: 10/23/2022]
|
35
|
|
36
|
|
37
|
|
38
|
Jiang Y, Jacobs M, Bajaksouzian S, Foster AN, Debanne SM, Bielefeld R, Garvey M, Raghupathy S, Kern J, Szczotka-Flynn LB. Risk Factors for Microbial Bioburden During Daily Wear of Silicone Hydrogel Contact Lenses. Eye Contact Lens 2014; 40:148-56. [DOI: 10.1097/icl.0000000000000026] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
39
|
Kuzman T, Kutija MB, Juri J, Jandroković S, Škegro I, Olujić SM, Kordić R, Cerovski B. Lens wearers non-compliance—Is there an association with lens case contamination? Cont Lens Anterior Eye 2014; 37:99-105. [DOI: 10.1016/j.clae.2013.08.004] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2013] [Revised: 08/01/2013] [Accepted: 08/02/2013] [Indexed: 11/30/2022]
|
40
|
|
41
|
Microbial Keratitis Secondary to Unintended Poor Compliance With Scleral Gas-Permeable Contact Lenses. Eye Contact Lens 2014; 40:e1-4. [DOI: 10.1097/icl.0b013e318273420f] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
42
|
Panthi S, Paudel P, Chaudhary M, Sapkota K, Shah DN. Microbial contamination of contact lens care accessories and compliance with care regimens in Nepal. Cont Lens Anterior Eye 2013; 37:2-10. [PMID: 23916116 DOI: 10.1016/j.clae.2013.07.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2012] [Revised: 06/09/2013] [Accepted: 07/03/2013] [Indexed: 10/26/2022]
Abstract
PURPOSE To determine the rates of microbial contamination and identify contaminants associated with contact lens (CL) care accessories. To investigate self-reported compliance levels with care of CL accessories and its association with contamination level. METHODS A total of 46 CL cases and care solutions from asymptomatic soft contact lens wearers were collected. Samples from the CL cases and care solutions were cultured for microbiological identification and enumeration. A questionnaire regarding compliance to care and hygiene procedures were administered to each subject on their visit. RESULTS The percentage of microbial contamination for CL cases and care solutions was 50% and 10.9%, respectively. All the contaminants were bacterial. Staphylococcus aureus (37.0%, 17 of 46 cases) and Escherichia coli (8.7%, 4 of 46 cases) were the most common microorganisms detected in CL cases. In care solutions, S. aureus (8.7%, 4 of 46 samples), Pseudomonas aeruginosa (2.2%, 1 of 46 samples) were common contaminants. CL cases and care solutions that were used for <3 months were significantly less contaminated than those used for >3 months (10.9% versus 39.1%, p<0.05). Polyquad and Aldox based MPS solution showed no contamination. Subjects with medium or low compliance had highly significant rates of contaminations both in CL cases and solutions than for subjects with high compliance (p<0.05). CONCLUSIONS Nepalese Soft CL wearers are at high risk of developing ocular complications due to high CL case and solution contamination. Frequent replacement of CL cases and solutions, as well as good compliance is recommended to reduce risk of contamination.
Collapse
Affiliation(s)
- Shyam Panthi
- College of Optometry, University of Houston, Houston, TX, USA.
| | - Prakash Paudel
- Brien Holden Vision Institute, University of New South Wales, Sydney, NSW, Australia
| | - Meenu Chaudhary
- B.P. Koirala Lions Center for Ophthalmic Studies, Tribhuvan University, Kathmandu, Nepal
| | | | - Dev N Shah
- B.P. Koirala Lions Center for Ophthalmic Studies, Tribhuvan University, Kathmandu, Nepal
| |
Collapse
|
43
|
Antimicrobial efficacy tests of multipurpose contact lens care solutions simulating poor contact lens hygiene behaviors. Eye Contact Lens 2013; 38:388-93. [PMID: 22669007 DOI: 10.1097/icl.0b013e3182562d9f] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE The aim of this study was to simulate the biofilm formation in contact lens (CL) case under poor hygiene behaviors; antimicrobial efficacies of multipurpose solutions (MPSs) against biofilm on the lens case were evaluated. METHODS Five MPSs (Epica Cold, Complete 10 min, ReNu MultiPlus, SoftOne Mois, and OPTI-FREE Plus) were tested. Lens cases containing ACUVUE2 were inoculated with 1×10, 10, or 10 colony-forming units (CFUs) of Staphylococcus epidermidis (SE). Each lens case was treated with 1 MPS for 4 hrs followed by the estimation of the number of SE by the CFU method. Disinfection efficacies of MPSs against SE biofilm were evaluated by biomicroscopy with safranin staining and scanning electron microscopy. RESULTS Lens cases, inoculated with 1×10 CFU, were disinfected by all MPSs. Epica Cold, Complete 10 min, ReNu MultiPlus, and OPTI-FREE showed almost a 2-log reduction of the CFU, whereas SoftOne Mois effect was almost a 1 log reduction, significantly lower than other MPSs (P<0.05). No biofilm formations were observed in Epica Cold, Complete 10 min, ReNu MultiPlus, and OPTI-FREE Plus-treated groups unlike significant biofilm formation in the SoftOne Mois-treated group (P<0.01). CONCLUSIONS Greater efforts to educate patients regarding compliant lens care behavior are needed to reduce the incidence of CL-associated microbial keratitis.
Collapse
|
44
|
Cho P, Boost M. Daily disposable lenses: The better alternative. Cont Lens Anterior Eye 2013; 36:4-12. [DOI: 10.1016/j.clae.2012.10.073] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2012] [Revised: 09/14/2012] [Accepted: 10/02/2012] [Indexed: 01/28/2023]
|
45
|
|
46
|
Morgan PB, Bright FV, Burke SE, Chalmers RL, Dobson C, Fleiszig SM, Hutter JC, Papas E, Peterson RC, Stapleton F. 4. Contemporary research in contact lens care. Cont Lens Anterior Eye 2013; 36 Suppl 1:S22-7. [PMID: 23347572 DOI: 10.1016/s1367-0484(13)60006-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
47
|
Boost MV, Shi G, Cho P. Comparison of Contamination Rates of Designs of Rigid Contact Lens Cases. Optom Vis Sci 2012; 89:E1030-4. [DOI: 10.1097/opx.0b013e31825da44a] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
48
|
Robertson DM, Cavanagh HD. Non-compliance with contact lens wear and care practices: a comparative analysis. Optom Vis Sci 2012; 88:1402-8. [PMID: 21946785 DOI: 10.1097/opx.0b013e3182333cf9] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To compare the effects of existing patient awareness of lens-related complications and underlying risk factors on actual patient behavior during contact lens wear and care practices in two different clinical study populations. METHODS Established contact lens wearers (n = 281) completed an anonymous written questionnaire on presenting to their habitual eye care practitioner in the Dallas-Fort Worth metroplex. Data were analyzed and compared against a second study population, which comprised established contact lens wearers (n = 152) who were sequentially evaluated after their routine contact lens examination at the University of Texas Southwestern Medical Center at Dallas, TX (UTSW). All patients were questioned regarding his or her lens care practices and knowledge of complications and risk factors associated with contact lens wear. RESULTS Fifty-eight percent of patients in the general community could identify by name a complication associated with lens wear compared with 91% within the medical center. The most frequent complications reported were related to comfort and handling (72%, Dallas-Fort Worth) and infection (47%, UTSW). The majority of patients could correctly identify risk factors associated with lens-related complications; awareness for topping-off solutions, tap water exposure, and hygiene varied between groups. Overall, 85% of patients perceived themselves as compliant with their lens wear and care practices. Using a standard scoring model to determine actual compliance, 2% of patients demonstrated good compliance; however, only 0.4% of patients were fully compliant with contact lens wear and care practices. CONCLUSIONS The data reveal some study bias in complication and risk awareness between populations; however, despite this limitation, a significant proportion of patients exhibited actual non-compliant behavior despite acknowledged awareness of risk. Although most patients consider themselves to be complying with standard practitioner guidelines for lens wear and care practices, essentially all contact lens wearing patients exhibit behavioral non-compliance with resulting increased risk for significant complications.
Collapse
Affiliation(s)
- Danielle M Robertson
- The Department of Ophthalmology, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, Texas 75390-9057, USA.
| | | |
Collapse
|
49
|
The impact of cellular debris on Pseudomonas aeruginosa adherence to silicone hydrogel contact lenses and contact lens storage cases. Eye Contact Lens 2012; 38:7-15. [PMID: 22138709 DOI: 10.1097/icl.0b013e31823bad0e] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To evaluate neutrophil-enhanced Pseudomonas aeruginosa (PA) biofilm formation on silicone hydrogel contact lenses and to determine the effect of epithelial biodebris on PA adherence in contact lens storage cases. METHODS A fully invasive PA corneal isolate stably conjugated to green fluorescent protein was used. Unworn lotrafilcon A contact lenses were incubated at various ratios of PA to polymorphonuclear neutrophil (PMN) for 24 hours at 37°C. Lens-associated PA was evaluated using laser scanning confocal microscopy and nonviable PA were visualized using propidium iodide. Viable bacteria were enumerated by colony-forming unit (CFU) analysis. For acute epithelial cell studies, PA viability was determined after coincubation with freeze-thaw epithelial cell lysates in 96-well polystyrene plates. Levels of residual cellular debris and bacterial viability were further assessed in used contact lens storage cases. RESULTS Laser scanning confocal microscopy demonstrated that cotreatment with PMA-stimulated neutrophils increased PA adherence over 24 hours to lens surfaces with a striking alteration of PA architecture. Propidium iodide staining showed that the adherent bacteria consisted of a mixture of viable and nonviable PA; a PMN-associated increase in viable PA was confirmed by CFU (PA:PMN 0.1:1, P = 0.025; PA:PMN 1:1, P = 0.005). Acute epithelial cell debris studies revealed a significant increase in viable PA in 96-well plates in the presence of epithelial freeze-thaw lysates (PA:debris 1:1, P = 0.002; PA:debris 100:1, P = 0.002). Crystal violet staining of used lens storage cases revealed residual cellular debris at all time points, which was independent of microbial contamination; all lens cases used for periods of 9 months or more were uniformly associated with high levels of viable microorganisms. CONCLUSION These results demonstrate that prolonged corneal inflammation with the presence of PMNs when confronted with simultaneous PA challenge in extended contact lens wear has the potential to stimulate biofilm formation on silicone hydrogel contact lenses. These findings further suggest that a persistent buildup of extracellular debris in lens storage cases may contribute to the heavy biofilms reported on these surfaces.
Collapse
|
50
|
Contact Lens Case Cleaning Procedures Affect Storage Solution pH and Osmolality. Optom Vis Sci 2011; 88:1414-21. [DOI: 10.1097/opx.0b013e318230375f] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|