1
|
Klotz R, Emile G, Daviet JC, De Sèze M, Godet J, Urbinelli R, Krasny-Pacini A. Daily socket comfort in transtibial amputee with a vacuum-assisted suspension system: study protocol of a randomized, multicenter, double-blind multiple N-of-1 trial. BMC Sports Sci Med Rehabil 2023; 15:85. [PMID: 37452356 PMCID: PMC10347726 DOI: 10.1186/s13102-023-00694-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Accepted: 06/25/2023] [Indexed: 07/18/2023]
Abstract
BACKGROUND The main aim of this paper is to present the feasibility of rigorously designed multiple N-of-1 design in prosthetics research. While research of adequate power and high quality is often lacking in rehabilitation, N-of-1 trials can offer a feasible alternative to randomized controlled group trials, both increasing design power at group level and allowing a rigorous, statistically confirmed evaluation of effectiveness at a single patient level. The paper presents a multiple N-of-1 trial protocol, which aim is to evaluate the effectiveness of Unity, a prosthetic add-on suspension system for amputees, on patient-reported comfort during daily activities (main outcome measure), prosthesis wearing time, perception of limb-prosthesis fitting and stump volume and functional walking parameters. METHODS Multicenter, randomized, prospective, double-blind multiple N-of-1 trial using an introduction/withdrawal design alternating Unity connected/disconnected phases of randomized length on twenty patients with unilateral transtibial amputation. The primary outcome measure is the Prosthetic Socket Comfort Score (SCS), a validated measure of comfort, administered daily by an phone app designed for the study. Secondary outcomes measures will be collected during the 50 days period of the N-of-1 trial: (1) by the same app, daily for patient-reported limb-prosthesis fitting, stump volume variation, and daily wearing time of the prosthesis; (2) by a pedometer for the number of steps per day; (3) by blind assessors in the rehabilitation center during adjustment visits for functional walking parameter (L-Test, 6-minute walk test), and by the patient for the QUEST, and ABC-S. Effectiveness of the Unity system regarding SCS and daily secondary outcome measures will be tested by randomization test. The secondary outcome measures assessed during visits in the rehabilitation center will be analyzed by Non Overlap of All pairs. An estimate of the effect on the amputee population will be generated by aggregating each individual clinical trial (N-of-1 trial) by Hierarchical Bayesian methods. DISCUSSION This study protocol was designed to answer the question "which device is best for THIS patient" and to conclude at a group level on the effectiveness of a new devic, using a Multiple N-of-1 trial, which is promising but underused in prosthetics research so far. TRIAL REGISTRATION N° ID-RCB 2020-A01309-30 Clintrial.gov : NCT04804150 - Retrospectively registered March 20th 2021.
Collapse
Affiliation(s)
- Rémi Klotz
- La Tour de Gassies Centre for Physical Medicine and Rehabilitation, UGECAM, Rue de la Tour de Gassies, Bruges, 33523, France
| | - Guilhem Emile
- Department of Physical and Rehabilitation Medicine, Centre Hospitalier d'Arcachon, Avenue Jean Hameau, 33260, La Teste de Buch, France
| | - Jean-Christophe Daviet
- Department of Physical and Rehabilitation Medicine, Limoges University, Jean Rebeyrol Hospital, Avenue du Buisson, 87170, Limoges, France
| | - Mathieu De Sèze
- Physical and Rehabilitation Medicine Unit, Bordeaux University Hospital, University of Bordeaux, EA4136, Bordeaux, France
| | - Julien Godet
- Clinical Research Methods Group, Laboratory of Bioimaging and Pathologies, UMR CNRS 7021, University Hospitals of Strasbourg, Illkirch, Strasbourg, France
| | | | - Agata Krasny-Pacini
- Department of Physical and Rehabilitation Medicine, UF 4372, CHU de Strasbourg, Institut Universitaire de Réadaptation Clémenceau, 45 Boulevard Clémenceau, Strasbourg, 67000, France
- Department of Psychiatry, Hôpital civil, INSERM 1114, Strasbourg University Hospital, Strasbourg, France
| |
Collapse
|
2
|
Abu Osman NA, Eshraghi A, Gholizadeh H, Wan Abas WAB, Lechler K. Prosthesis donning and doffing questionnaire: Development and validation. Prosthet Orthot Int 2017; 41:571-578. [PMID: 28190376 DOI: 10.1177/0309364617690397] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
OBJECTIVES To develop a questionnaire that specifically evaluates the ability of trans-tibial amputees to don and doff a prosthesis and to investigate the psychometric properties of the newly developed questionnaire. BACKGROUND Prosthesis should be donned and doffed few times during the day and night; thus, it is important to measure ease of donning and doffing. STUDY DESIGN A cross-sectional study. METHODS The questionnaire was designed and evaluated by a group of experts. The final questionnaire was administered to 50 individuals with trans-tibial amputation. A test-retest study was also conducted on 20 amputees to assess the repeatability of questionnaire items. RESULTS The prosthesis donning and doffing questionnaire was developed and tested through a pilot study. Based on Kappa index, the questionnaire items showed correlation coefficients greater than 0.7, which indicate good reliability and repeatability. The majority of the participants had good hand dexterity (80%) and could perform all types of grasps. The mean satisfaction scores with donning and doffing were 69.9 and 81.4, respectively. Most of the respondents needed to don and doff the prosthesis 3.44 times per day. Based on a 7-point score, the total scores ranged between 3 and 7. CONCLUSION The prosthesis donning and doffing questionnaire items showed good psychometric properties. A scoring method was suggested based on the pilot sample, which requires further evaluation to be able to differentiate between more suspension types. A larger international multicenter evaluation is required in the future to measure the responsiveness of the scales. This questionnaire will be useful in the evaluation of the ability of amputees to don and doff a trans-tibial limb prosthesis. Clinical relevance Donning and doffing of prostheses are challenging tasks for many lower limb amputees. The prosthesis donning and doffing questionnaire, on its own or combined with other prosthetic evaluation questionnaires, has the potential to help manufacturers, clinicians, and researchers gain knowledge and improve the donning and doffing qualities of prostheses.
Collapse
Affiliation(s)
- Noor Azuan Abu Osman
- 1 Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - Arezoo Eshraghi
- 1 Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia.,2 Holland Bloorview Kids Rehabilitation Hospital, Toronto, ON, Canada
| | - Hossein Gholizadeh
- 1 Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia.,3 Ottawa Hospital Research Institute, Centre for Rehabilitation Research and Development, Ottawa, Canada
| | - Wan Abu Bakar Wan Abas
- 1 Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - Knut Lechler
- 4 Ossur ehf, R&D Medical Office, Reykjavik, Iceland
| |
Collapse
|
3
|
Al-Fakih EA, Abu Osman NA, Mahmad Adikan FR. Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research. SENSORS 2016; 16:s16071119. [PMID: 27447646 PMCID: PMC4970162 DOI: 10.3390/s16071119] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2016] [Revised: 05/12/2016] [Accepted: 06/02/2016] [Indexed: 11/18/2022]
Abstract
The distribution of interface stresses between the residual limb and prosthetic socket of a transtibial amputee has been considered as a direct indicator of the socket quality fit and comfort. Therefore, researchers have been very interested in quantifying these interface stresses in order to evaluate the extent of any potential damage caused by the socket to the residual limb tissues. During the past 50 years a variety of measurement techniques have been employed in an effort to identify sites of excessive stresses which may lead to skin breakdown, compare stress distributions in various socket designs, and evaluate interface cushioning and suspension systems, among others. The outcomes of such measurement techniques have contributed to improving the design and fitting of transtibial sockets. This article aims to review the operating principles, advantages, and disadvantages of conventional and emerging techniques used for interface stress measurements inside transtibial sockets. It also reviews and discusses the evolution of different socket concepts and interface stress investigations conducted in the past five decades, providing valuable insights into the latest trends in socket designs and the crucial considerations for effective stress measurement tools that lead to a functional prosthetic socket.
Collapse
Affiliation(s)
- Ebrahim A Al-Fakih
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur 50603, Malaysia.
| | - Noor Azuan Abu Osman
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur 50603, Malaysia.
| | - Faisal Rafiq Mahmad Adikan
- Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur 50603, Malaysia.
| |
Collapse
|
4
|
Safari MR, Meier MR. Systematic review of effects of current transtibial prosthetic socket designs-Part 1: Qualitative outcomes. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT 2015; 52:491-508. [PMID: 26436666 DOI: 10.1682/jrrd.2014.08.0183] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Revised: 04/23/2015] [Indexed: 11/05/2022]
Abstract
This review is an attempt to untangle the complexity of transtibial prosthetic socket fit, determine the most important characteristic for a successful fitting, and perhaps find some indication of whether a particular prosthetic socket type might be best for a given situation. Further, it is intended to provide directions for future research. We followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines and used medical subject headings and standard key words to search for articles in relevant databases. No restrictions were made on study design or type of outcome measure. From the obtained search results (n = 1,863), 35 articles were included. The relevant data were entered into a predefined data form that incorporated the Downs and Black risk of bias assessment checklist. Results for the qualitative outcomes (n = 19 articles) are synthesized. Total surface bearing sockets lead to greater activity levels and satisfaction in active persons with amputation, those with a traumatic cause of amputation, and younger persons with amputation than patellar tendon bearing sockets. Evidence on vacuum-assisted suction and hydrostatic sockets is inadequate, and further studies are much needed. To improve the scientific basis for prescription, comparison of and correlation between mechanical properties of interface material, socket designs, user characteristics, and outcome measures should be conducted and reported in future studies.
Collapse
Affiliation(s)
- Mohammad Reza Safari
- Department of Orthotics and Prosthetics, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
| | | |
Collapse
|
5
|
Safari MR, Meier MR. Systematic review of effects of current transtibial prosthetic socket designs--Part 2: Quantitative outcomes. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT 2015; 52:509-26. [PMID: 26436733 DOI: 10.1682/jrrd.2014.08.0184] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Revised: 04/14/2015] [Indexed: 11/05/2022]
Abstract
This review is an attempt to untangle the complexity of transtibial prosthetic socket fit and perhaps find some indication of whether a particular prosthetic socket type might be best for a given situation. In addition, we identified knowledge gaps, thus providing direction for possible future research. We followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines, using medical subject headings and standard key words to search for articles in relevant databases. No restrictions were made on study design and type of outcome measure used. From the obtained search results (n = 1,863), 35 articles were included. The relevant data were entered into a predefined data form that included the Downs and Black risk of bias assessment checklist. This article presents the results from the systematic review of the quantitative outcomes (n = 27 articles). Trends indicate that vacuum-assisted suction sockets improve gait symmetry, volume control, and residual limb health more than other socket designs. Hydrostatic sockets seem to create less inconsistent socket fittings, reducing a problem that greatly influences outcome measures. Knowledge gaps exist in the understanding of clinically meaningful changes in socket fit and its effect on biomechanical outcomes. Further, safe and comfortable pressure thresholds under various conditions should be determined through a systematic approach.
Collapse
Affiliation(s)
- Mohammad Reza Safari
- Department of Orthotics and Prosthetics, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
| | | |
Collapse
|
6
|
|
7
|
Gholizadeh H, Osman NAA, Eshraghi A, Abd Razak NA. Clinical implication of interface pressure for a new prosthetic suspension system. Biomed Eng Online 2014; 13:89. [PMID: 24981801 PMCID: PMC4090423 DOI: 10.1186/1475-925x-13-89] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2014] [Accepted: 06/24/2014] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Prosthesis suspension systems can alter the distribution of pressure within the prosthetic socket. This study evaluates a new suspension system for lower limb prostheses, and aims to compare the interface pressure and amputees' satisfaction with the new system compared with a common prosthetic suspension system (pin/lock). METHODS Ten transtibial amputees walked at a self-selected speed on a level ground with two different suspension systems, namely the pin/lock and HOLO system. The interface pressure was measured using the F-socket transducers at the proximal, middle and distal sites of residual limb. Furthermore, subjective feedback was logged to compare two systems. RESULTS The pressure was significantly higher at the proximal and distal areas with the pin/lock suspension system during the swing phase of gait (P<0.05). Subjective feedback also showed traction at the stump with the pin/lock system. There were no significant differences in the pressure applied to the mid-anterior and mid posterior stump for both suspension systems. However, the lateral and medial sides exhibited higher pressure with the new system during stance phase. CONCLUSIONS The intention of this study was to deepen understanding on the effect of suspension system on the load distribution over the residual limb. The new coupling system was proved compatible with the pin/lock system in terms of suspending the leg and amputee's satisfaction. On the other hand, the HOLO system could distribute the pressure more uniformly over the residual limb.
Collapse
Affiliation(s)
- Hossein Gholizadeh
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia.
| | | | | | | |
Collapse
|
8
|
The effects of suction and pin/lock suspension systems on transtibial amputees' gait performance. PLoS One 2014; 9:e94520. [PMID: 24827560 PMCID: PMC4021017 DOI: 10.1371/journal.pone.0094520] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2013] [Accepted: 03/14/2014] [Indexed: 11/20/2022] Open
Abstract
Background The suction sockets that are commonly prescribed for transtibial amputees are believed to provide a better suspension than the pin/lock systems. Nevertheless, their effect on amputees’ gait performance has not yet been fully investigated. The main intention of this study was to understand the potential effects of the Seal-in (suction) and the Dermo (pin/lock) suspension systems on amputees’ gait performance. Methodology/Principal Findings Ten unilateral transtibial amputees participated in this prospective study, and two prostheses were fabricated for each of them. A three-dimensional motion analysis system was used to evaluate the temporal-spatial, kinematics and kinetics variables during normal walking. We also asked the participants to complete some part of Prosthesis Evaluation Questionnaire (PEQ) regarding their satisfaction and problems with both systems. The results revealed that there was more symmetry in temporal-spatial parameters between the prosthetic and sound limbs using the suction system. However, the difference between two systems was not significant (p<0.05). Evaluation of kinetic data and the subjects’ feedback showed that the participants had more confidence using the suction socket and the sockets were more fit for walking. Nevertheless, the participants had more complaints with this system due to the difficulty in donning and doffing. Conclusion It can be concluded that even though the suction socket could create better suspension, fit, and gait performance, overall satisfaction was higher with the pin/lock system due to easy donning and doffing of the prosthesis. Trial Registration irct.ir IRCT2014012816395N1
Collapse
|
9
|
Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S, Razak NA. Transtibial prosthesis suspension systems: systematic review of literature. Clin Biomech (Bristol, Avon) 2014; 29:87-97. [PMID: 24315710 DOI: 10.1016/j.clinbiomech.2013.10.013] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2013] [Revised: 10/18/2013] [Accepted: 10/21/2013] [Indexed: 02/07/2023]
Abstract
BACKGROUND Today a number of prosthetic suspension systems are available for transtibial amputees. Consideration of an appropriate suspension system can ensure that amputee's functional needs are satisfied. The higher the insight to suspension systems, the easier would be the selection for prosthetists. This review attempted to find scientific evidence pertaining to various transtibial suspension systems to provide selection criteria for clinicians. METHODS Databases of PubMed, Web of Science, and ScienceDirect were explored to find related articles. Search terms were as follows: "Transtibial prosthesis (32), prosthetic suspension (48), lower limb prosthesis (54), below-knee prosthesis (58), prosthetic liner (20), transtibial (193), and prosthetic socket (111)". Two reviewers separately examined the papers. Study design (case series of five or more subjects, retrospective or prospective), research instrument, sampling method, outcome measures and protocols were reviewed. FINDINGS Based on the selection criteria, 22 articles (15 prospective studies, and 7 surveys) remained. Sweat control was found to be a major concern with the available suspension liners. Donning and doffing procedures for soft liners are also problematic for some users, particularly those with upper limb weakness. Moreover, the total surface bearing (TSB) socket with pin/lock system is favored by the majority of amputees. INTERPRETATION In summary, no clinical evidence is available to suggest what kind of suspension system could have an influential effect as a "standard" system for all transtibial amputees. However, among various suspension systems for transtibial amputees, the Iceross system was favored by the majority of users in terms of function and comfort.
Collapse
Affiliation(s)
- H Gholizadeh
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Malaysia.
| | - N A Abu Osman
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Malaysia
| | - A Eshraghi
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Malaysia
| | - S Ali
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Malaysia
| | - N A Razak
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Malaysia
| |
Collapse
|
10
|
Eshraghi A, Abu Osman NA, Gholizadeh H, Ali S, Sævarsson SK, Wan Abas WAB. An experimental study of the interface pressure profile during level walking of a new suspension system for lower limb amputees. Clin Biomech (Bristol, Avon) 2013; 28:55-60. [PMID: 23157843 DOI: 10.1016/j.clinbiomech.2012.10.002] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2012] [Revised: 10/05/2012] [Accepted: 10/08/2012] [Indexed: 02/07/2023]
Abstract
BACKGROUND Different suspension systems that are used within prosthetic devices may alter the distribution of pressure inside the prosthetic socket in lower limb amputees. This study aimed to compare the interface pressure of a new magnetic suspension system with the pin/lock and Seal-In suspension systems. METHODS Twelve unilateral transtibial amputees participated in the study. The subjects walked on a level walkway at a self-selected speed. The resultant peak pressure with the three different suspension systems was recorded using F-socket transducers. FINDINGS There were significant statistical differences between the three studied suspension systems. Pair-wise analyses revealed that the mean peak pressure (kPa) was lower with the magnetic system than it was with the pin/lock system over the anterior and posterior aspects during one gait cycle (89.89 vs. 79.26 and 47.22 vs. 26.01, respectively). Overall, the average peak pressure values were higher with the Seal-In system than they were with the new magnetic lock and pin/lock system. INTERPRETATION The new magnetic system might reduce the pressure within the prosthetic socket in comparison to the pin/lock and Seal-In system during one gait cycle. This is particularly important during the swing phase of gait and may reduce the pain and discomfort at the distal residual limb in comparison to the pin/lock system.
Collapse
Affiliation(s)
- Arezoo Eshraghi
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia.
| | | | | | | | | | | |
Collapse
|
11
|
Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S, Yahyavi ES. Satisfaction and problems experienced with transfemoral suspension systems: a comparison between common suction socket and seal-in liner. Arch Phys Med Rehabil 2012; 94:1584-9. [PMID: 23262380 DOI: 10.1016/j.apmr.2012.12.007] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2012] [Revised: 12/04/2012] [Accepted: 12/04/2012] [Indexed: 11/18/2022]
Abstract
OBJECTIVE To compare a seal-in liner with the common suction socket with regards to patient satisfaction and problems experienced with the prosthesis. DESIGN Retrospective survey. SETTING A medical and engineering research center and a department of biomechanical engineering. PARTICIPANTS Men (N=90) with traumatic transfemoral amputation who used both suspension systems participated in the study. INTERVENTION Two prosthetic suspension systems: a seal-in liner and common suction socket. MAIN OUTCOME MEASURES Two questionnaires were completed by each subject to evaluate their satisfaction and problems experienced with the 2 suspension systems. Satisfaction and problems with the prosthetic suspension systems were analyzed in terms of fitting, donning and doffing, sitting, walking, stair negotiation, appearance, sweating, wounds, pain, irritation, pistoning, edema, smell, sound, and durability. RESULTS The study revealed that the respondents were more satisfied with a seal-in liner with regards to fitting, sitting, and donning and doffing. Overall satisfaction increased with the use of a seal-in liner compared with the suction socket (P<.05). However, satisfaction with the prosthesis showed no significant differences in terms of walking (flat and uneven surfaces), appearance, and stair negotiation. Furthermore, problems experienced differed significantly between the 2 suspension systems (P<.05). Sweating, wounds, pain, irritation, pistoning, edema, smell, and sound were less problematic with the use of a seal-in liner, whereas durability was significantly better with the suction socket. CONCLUSIONS The results of the survey suggest that satisfaction and problems with prosthetic suspension in persons with transfemoral amputation can be improved with a seal-in liner compared with the suction socket, provided that the durability of the liner is enhanced.
Collapse
Affiliation(s)
- Hossein Gholizadeh
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia.
| | | | | | | | | |
Collapse
|
12
|
Ali S, Osman NAA, Mortaza N, Eshraghi A, Gholizadeh H, Wan Abas WABB. Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction. Clin Biomech (Bristol, Avon) 2012; 27:943-8. [PMID: 22795863 DOI: 10.1016/j.clinbiomech.2012.06.004] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2012] [Revised: 06/05/2012] [Accepted: 06/06/2012] [Indexed: 02/07/2023]
Abstract
BACKGROUND The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. Liners provide a comfortable interface by adding a soft cushion between the residual limb and the socket. The Dermo and the Seal-In X5 liner are two new interface systems and, due to their relative infancy, very little are known about their effect on patient satisfaction. The aim of this study was to compare the interface pressure with these two liners and their effect on patient satisfaction. METHODS Nine unilateral transtibial amputees participated in the study. Two prostheses were fabricated for each amputee, one with the Seal-In liner and one with the Dermo liner. Interface pressure was measured at the anterior, posterior, medial and lateral regions during walking on the level ground. Each subject filled in a Prosthetic Evaluation Questionnaire (PEQ) regarding the satisfaction with the two liners. Findings The mean peak pressures with the Seal-In liner was 34.0% higher at the anterior, 24.0% higher at the posterior and 7.0% higher at the medial regions of the socket (P=0.008, P=0.046, P=0.025) than it was with the Dermo Liner. There were no significant differences in the mean peak pressures between the two liners at the lateral regions. In addition, significant difference was found between the two liners both for satisfaction and problems (P<0.05). Interpretation There was less interface pressure between the socket and the residual limb with the Dermo liner. The results indicated that the Dermo liner provides more comfort in the socket than the Seal-In liner.
Collapse
Affiliation(s)
- Sadeeq Ali
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Malaysia.
| | | | | | | | | | | |
Collapse
|