• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4670197)   Today's Articles (164)
For: Gholizadeh H, Abu Osman NA, Kamyab M, Eshraghi A, Lúvíksdóttir ÁG, Wan Abas WAB. Clinical Evaluation of Two Prosthetic Suspension Systems in a Bilateral Transtibial Amputee. Am J Phys Med Rehabil 2012;91:894-8. [DOI: 10.1097/phm.0b013e31823c74d7] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Number Cited by Other Article(s)
1
Klotz R, Emile G, Daviet JC, De Sèze M, Godet J, Urbinelli R, Krasny-Pacini A. Daily socket comfort in transtibial amputee with a vacuum-assisted suspension system: study protocol of a randomized, multicenter, double-blind multiple N-of-1 trial. BMC Sports Sci Med Rehabil 2023;15:85. [PMID: 37452356 PMCID: PMC10347726 DOI: 10.1186/s13102-023-00694-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Accepted: 06/25/2023] [Indexed: 07/18/2023]
2
Abu Osman NA, Eshraghi A, Gholizadeh H, Wan Abas WAB, Lechler K. Prosthesis donning and doffing questionnaire: Development and validation. Prosthet Orthot Int 2017;41:571-578. [PMID: 28190376 DOI: 10.1177/0309364617690397] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
3
Al-Fakih EA, Abu Osman NA, Mahmad Adikan FR. Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research. SENSORS 2016;16:s16071119. [PMID: 27447646 PMCID: PMC4970162 DOI: 10.3390/s16071119] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2016] [Revised: 05/12/2016] [Accepted: 06/02/2016] [Indexed: 11/18/2022]
4
Safari MR, Meier MR. Systematic review of effects of current transtibial prosthetic socket designs-Part 1: Qualitative outcomes. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT 2015;52:491-508. [PMID: 26436666 DOI: 10.1682/jrrd.2014.08.0183] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Revised: 04/23/2015] [Indexed: 11/05/2022]
5
Safari MR, Meier MR. Systematic review of effects of current transtibial prosthetic socket designs--Part 2: Quantitative outcomes. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT 2015;52:509-26. [PMID: 26436733 DOI: 10.1682/jrrd.2014.08.0184] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Revised: 04/14/2015] [Indexed: 11/05/2022]
6
Transfemoral Prosthesis Suspension Systems. Am J Phys Med Rehabil 2014;93:809-23. [DOI: 10.1097/phm.0000000000000094] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
7
Gholizadeh H, Osman NAA, Eshraghi A, Abd Razak NA. Clinical implication of interface pressure for a new prosthetic suspension system. Biomed Eng Online 2014;13:89. [PMID: 24981801 PMCID: PMC4090423 DOI: 10.1186/1475-925x-13-89] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2014] [Accepted: 06/24/2014] [Indexed: 11/10/2022]  Open
8
The effects of suction and pin/lock suspension systems on transtibial amputees' gait performance. PLoS One 2014;9:e94520. [PMID: 24827560 PMCID: PMC4021017 DOI: 10.1371/journal.pone.0094520] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2013] [Accepted: 03/14/2014] [Indexed: 11/20/2022]  Open
9
Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S, Razak NA. Transtibial prosthesis suspension systems: systematic review of literature. Clin Biomech (Bristol, Avon) 2014;29:87-97. [PMID: 24315710 DOI: 10.1016/j.clinbiomech.2013.10.013] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2013] [Revised: 10/18/2013] [Accepted: 10/21/2013] [Indexed: 02/07/2023]
10
Eshraghi A, Abu Osman NA, Gholizadeh H, Ali S, Sævarsson SK, Wan Abas WAB. An experimental study of the interface pressure profile during level walking of a new suspension system for lower limb amputees. Clin Biomech (Bristol, Avon) 2013;28:55-60. [PMID: 23157843 DOI: 10.1016/j.clinbiomech.2012.10.002] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2012] [Revised: 10/05/2012] [Accepted: 10/08/2012] [Indexed: 02/07/2023]
11
Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S, Yahyavi ES. Satisfaction and problems experienced with transfemoral suspension systems: a comparison between common suction socket and seal-in liner. Arch Phys Med Rehabil 2012;94:1584-9. [PMID: 23262380 DOI: 10.1016/j.apmr.2012.12.007] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2012] [Revised: 12/04/2012] [Accepted: 12/04/2012] [Indexed: 11/18/2022]
12
Ali S, Osman NAA, Mortaza N, Eshraghi A, Gholizadeh H, Wan Abas WABB. Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction. Clin Biomech (Bristol, Avon) 2012;27:943-8. [PMID: 22795863 DOI: 10.1016/j.clinbiomech.2012.06.004] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2012] [Revised: 06/05/2012] [Accepted: 06/06/2012] [Indexed: 02/07/2023]
PrevPage 1 of 1 1Next
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA