Fertsch S, Michalak M, Andree C, Munder B, Hagouan M, Schulz T, Stambera P, Steammler K, Grueter L, Kornetka J, Wolter A. Randomized Single-Center Study of Effectiveness and Safety of a Resorbable Lysine-Based Urethane Adhesive for a Drain-Free Closure of the Abdominal Donor Site in a DIEP Flap Breast Reconstruction Procedure.
J INVEST SURG 2022;
35:1404-1414. [PMID:
35263551 DOI:
10.1080/08941939.2022.2046215]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
OBJECTIVE
The hypothesis of this parallel group randomized trial testifies if TissuGlu is a safe and an effective alternative to the conventional drainage placement in regard to post-operative fluid management in the abdominal donor site for autologous (DIEP flap) breast reconstruction with a higher postoperative patient quality of life.
PATIENTS AND METHODS
Data was collected for 58 women who required to be at min.18 years old with a BMI < 30 and not taking any SSRIs (Selective Serotonin Reuptake Inhibitors).Exclusion criteria: Discharge with indwelling suction drains at the abdominal site or signs of wound infection during hospital stay.The patients were randomized into a study group (donor site closure with application of surgical adhesive without drains) and a control group (donor site closure with drains) using a randomly sorted sealed envelope system.Th e primary outcome was defined as the number of post-operative seroma formations.The secondary endpoint was the evaluation of patient satisfaction with both methods.
RESULTS
58 patients underwent a DIEP reconstruction (29 in the control- and 29 in the study group).Both groups were homogenous. Rate of seroma was 17%(5/29) in the study group and 10%(3/29) in the control group which showed no statistical significance (p-value = 0.71).Smoking and previous abdominal surgery turned out to be a risk factor for seroma formation in the study group.Overall satisfaction was evaluated with a questionnaire and was higher in the study group.
CONCLUSION
The abdominal closure with the surgical adhesive seems to be a safe procedure that contributes to patient satisfaction and increases the independence upon discharge in patients with adequate inclusion criteria.
Collapse