1
|
Comparative analysis on the outcomes in circumcising children using modified Chinese ShangRing and conventional surgical circumcision. Pediatr Surg Int 2022; 39:59. [PMID: 36550318 DOI: 10.1007/s00383-022-05343-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/10/2022] [Indexed: 12/24/2022]
Abstract
OBJECTIVE To compare the differences and outcomes of surgical procedures, clinical effect, complications and patients' satisfaction between disposable oval-shaped circumcision device (Modified Chinese ShangRing series, Kiddie love®) and conventional circumcision in the treatment of children with phimosis or redundant prepuce. METHODS The clinical data were retrospectively analyzed in 114 children with phimosis or redundant foreskin undergone circumcision using a disposable oval-shaped circumcision device, a modified Chinese ShangRing series, Kiddie Love® (Kiddie Love group) in our hospital between January 2018 and February 2020, and another 114 children with similar conditions circumcised by conventional surgical procedure before January 2018 (conventional group). The two groups were compared regarding the operative time, intraoperative blood loss, postoperative pain scores, healing time, the incidence of complications and guardian's satisfaction. RESULTS Circumcision was successfully completed in children in both groups. The operative time, intraoperative blood loss, postoperative pain scoring in 24 h by VAS, pain at the removal of the device or stitches and wound healing were (6.4 ± 1.6) min, (34.1 ± 6.4) min; (0.7 ± 0.2) ml, (2.6 ± 0.6) ml; (2.2 ± 1.0) points, (1.3 ± 0.5) points; (23.7 ± 3.9)day, (15.9 ± 2.8)day, respectively for Kiddie Love group and conventional group(either P < 0.05 or P > 0.05). The two groups were significantly different in the incidence of hematoma, edema and incision dehiscenceyet were insignificant in incision infection. Children in both groups were followed up from 6 to 31 months (mean: 23 months), and the satisfaction rate was 94.7% (108/114) in parents of the children circumcised by the ShangRing and 83.3% (95/114) in those of children treated by conventional circumcision (P < 0.05). CONCLUSION Modified Chinese ShangRing, Kiddie Love®, has superiorities, including simpler procedure, shorter operative time, less blood loss, fewer complications, better cosmetic results and higher satisfaction of patients over conventional circumcision in the treatment of children with phimosis or redundant foreskin, and worthy of wider clinical recommendation.
Collapse
|
2
|
Hohlfeld A, Ebrahim S, Shaik MZ, Kredo T. Circumcision devices versus standard surgical techniques in adolescent and adult male circumcisions. Cochrane Database Syst Rev 2021; 3:CD012250. [PMID: 33786810 PMCID: PMC8095026 DOI: 10.1002/14651858.cd012250.pub2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND Medical circumcisions are among the most common surgical procedures performed in males. The usual indications are phimosis (inability to completely retract the foreskin and expose the glans due to a congenital or acquired constriction of the prepuce), paraphimosis (when the foreskin is not pulled back over the glans after retraction resulting in a tight constricting band which causes swelling of the distal penis and acute discomfort), balanoposthitis (erythema and edema of the prepuce and glans) and balanitis (inflammation is confined to the glans; the foreskin is usually non-retractile). Circumcision devices have been developed to shorten the operative time, simplify techniques, and improve safety and cosmetic outcomes. The devices generally aim to crush the foreskin while simultaneously creating hemostasis, the foreskin is then excised or allowed to slough off. Their use is supposedly safer and easier to replicate than the standard dissection techniques. There are at least 20 devices for male circumcision on the market, yet their effectiveness has not been reviewed to date. OBJECTIVES To assess the effects of device-based circumcisions compared with standard surgical techniques in adolescent and adult males (10 years old and above). SEARCH METHODS We performed a comprehensive search with no restrictions to the language of publication or publication status. We searched the Cochrane Library, MEDLINE (PubMed), Embase, Web of Science, trials registries, grey literature sources and conference proceedings up to 16 April 2020. SELECTION CRITERIA We included randomized controlled trials of device-based circumcisions (crush or ligature circumcision devices) compared to standard surgical dissection-based circumcision conducted by health professionals in a medical setting. DATA COLLECTION AND ANALYSIS At least two review authors independently assessed study eligibility and extracted data from the included studies. We classified adverse events into serious, moderate or mild. We reported study results as risk ratios (RR) or mean differences (MD) using 95% confidence intervals (CI) and a random-effects model. We used the GRADE approach to evaluate the overall certainty of the evidence for each outcome. MAIN RESULTS Eighteen trials met the inclusion criteria. Trials were conducted in China, South Africa, Kenya and Zambia, Mozambique, Rwanda, Uganda and Zimbabwe. Primary outcomes Serious adverse events: there were no serious adverse events in either treatment arm (11 trials, 3472 participants). Moderate adverse events: there may be a slight increase in moderate adverse events when devices are used compared to standard surgical techniques (RR 1.31, 95% CI 0.55 to 3.10; I²= 68%; 10 trials, 3370 participants; low-certainty evidence); this corresponds to 8 more (ranging from 15 fewer to 84 more) moderate adverse events per 1000 participants. We downgraded the certainty of the evidence for study limitations and imprecision. Secondary outcomes Mild adverse events: we are uncertain about the difference in mild adverse events between groups when devices are used compared to standard surgical techniques (RR 1.09, 95% CI 0.44 to 2.72; I² = 91%; 10 trials, 3370 participants; very low-certainty evidence). We downgraded the certainty of the evidence for study limitations, imprecision and unexplained inconsistency. Operative time: operative time is probably about 17 minutes shorter when using a device rather than standard surgical techniques, which constitutes a clinically meaningful decrease in a procedure (MD -17.26 minutes, 95% CI -19.96 to -14.57; I² = 99%; 14 trials, 4812 participants; moderate-certainty evidence). We downgraded the certainty of the evidence for serious study limitations. The standard surgical technique generally takes about 24 minutes. There may be less postoperative pain during the first 24 hours when circumcision devices are used compared to standard surgical techniques (measured using a visual analog scale [VAS]; MD 1.30 cm lower, 95% CI 2.37 lower to 0.22 lower; I² = 99%; 9 trials, 3022 participants; low-certainty evidence). We downgraded the certainty of the evidence for study limitations and unexplained heterogeneity. There may be little or no difference in postoperative pain experienced during the first seven days when compared with standard surgical techniques (measured using a VAS; MD 0.11 cm higher, 95% CI 0.89 lower to 1.11 higher; I² = 94%; 4 trials, 1430 participants; low-certainty evidence). We downgraded the certainty of the evidence for study limitations and unexplained inconsistency. A higher score on the VAS indicates greater pain. Participants may slightly prefer circumcision devices compared to standard surgical techniques (RR 1.19, 95% CI 1.04 to 1.37; I² = 97%; 15 trials, 4501 participants; low-certainty evidence). We downgraded the certainty of the evidence for study limitations and unexplained inconsistency. We recorded satisfaction as a dichotomous outcome. Higher rates reflected greater satisfaction. AUTHORS' CONCLUSIONS We found that there were no serious adverse events reported when using a circumcision device compared to standard surgical techniques, but they may slightly increase moderate adverse effects, and it is unclear whether there is a difference in mild adverse effects. Use of circumcision devices probably reduces the time of the procedure by about 17 minutes, a clinically meaningful time saving. For patients, use of the circumcision device may result in lower pain scores during the first 24 hours and patients may be slightly more satisfied with it compared with standard surgical techniques. Clinicians, patients and policymakers can use these results in conjunction with their own contextual factors to inform the approach that best suits their healthcare settings. High-quality trials evaluating this intervention are needed to provide further certainty regarding the rates of adverse effects and postoperative pain of using devices compared to standard approaches.
Collapse
Affiliation(s)
- Ameer Hohlfeld
- Cochrane South Africa, South African Medical Research Council, Cape Town, South Africa
| | - Sumayyah Ebrahim
- School of Clinical Medicine, Department of Surgery, University of KwaZulu-Natal, Durban, South Africa
| | - Muhammed Zaki Shaik
- School of Clinical Medicine, Department of Surgery, University of KwaZulu-Natal, Durban, South Africa
| | - Tamara Kredo
- Cochrane South Africa, South African Medical Research Council, Cape Town, South Africa
| |
Collapse
|
3
|
Fang L, Zhu W, Xie Z, Wu K, Wang G, Yan Z, Zheng Z, Ma Q, Cheng Y. Choosing the appropriate ShangRing size for paediatric circumcision using the no-flip technique. J Paediatr Child Health 2018; 54:42-48. [PMID: 28799669 DOI: 10.1111/jpc.13660] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2016] [Accepted: 06/12/2017] [Indexed: 11/30/2022]
Abstract
AIM To determine the correct ShangRing size for paediatric circumcision using the no-flip technique. METHODS A cohort of 104 boys (from 6 to 14 years) underwent ShangRing circumcision at Ningbo First Hospital, China. The patients were randomly divided into three groups according to the different methods used for choosing the ring size. For Group A, the ring size was chosen using the ShangRing measuring tape; for Group B, ring size was chosen based on the diameter of penis measured using a self-designed scale plate; and for Group C, ring size was chosen based on the diameter of the glans measured using the self-designed scale plate. The surgery duration, foreskin dorsal slit rate, intra-operative and post-surgery pain score, pain duration, post-surgery ring detachment duration, pain score for ring detachment, complication rate and satisfaction rate were compared. RESULTS Group A had the highest dorsal slit rate and the longest surgical period. There were no significant differences in intra-/post-surgery pain or ring detachment duration among the three groups. The post-surgery oedema rate and foreskin asymmetry occurrence rate was the highest in Group A at 40.62 and 21.88%, respectively. Group C had the highest satisfaction rate (97.14%), with a significant difference from Group A (75.00%). Oedema and asymmetry of the foreskin increased, while the satisfaction rate simultaneously decreased when a larger ShangRing was chosen. CONCLUSIONS The size of the ShangRing should be chosen in accordance with the diameter of the glans in paediatric ShangRing circumcision using the no-flip technique.
Collapse
Affiliation(s)
- Li Fang
- Department of Urology, Ningbo First Hospital, Ningbo Hospital of Zhejiang University, Ningbo, Zhejiang, China
| | - Weichao Zhu
- Department of Pediatric Surgery, Affiliated Hospital of Medical College, Ningbo University, Ningbo, Zhejiang, China
| | - Zhongfei Xie
- Department of Urology, Ningbo First Hospital, Ningbo Hospital of Zhejiang University, Ningbo, Zhejiang, China
| | - Kerong Wu
- Department of Urology, Ningbo First Hospital, Ningbo Hospital of Zhejiang University, Ningbo, Zhejiang, China
| | - Guoyao Wang
- Department of Urology, Ningbo First Hospital, Ningbo Hospital of Zhejiang University, Ningbo, Zhejiang, China
| | - Zejun Yan
- Department of Urology, Ningbo First Hospital, Ningbo Hospital of Zhejiang University, Ningbo, Zhejiang, China
| | - Zhong Zheng
- Department of Urology, Ningbo First Hospital, Ningbo Hospital of Zhejiang University, Ningbo, Zhejiang, China
| | - Qi Ma
- Department of Urology, Ningbo First Hospital, Ningbo Hospital of Zhejiang University, Ningbo, Zhejiang, China
| | - Yue Cheng
- Department of Urology, Ningbo First Hospital, Ningbo Hospital of Zhejiang University, Ningbo, Zhejiang, China
| |
Collapse
|
4
|
Randomized Controlled Trial of the ShangRing for Adult Medical Male Circumcision: Safety, Effectiveness, and Acceptability of Using 7 Versus 14 Device Sizes. J Acquir Immune Defic Syndr 2017; 72 Suppl 1:S30-5. [PMID: 27331587 PMCID: PMC4936423 DOI: 10.1097/qai.0000000000001015] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Objectives: To assess the safety, effectiveness, and acceptability of providing a reduced number of ShangRing sizes for adult voluntary medical male circumcision (VMMC) within routine service delivery in Lusaka, Zambia. Methods: We conducted a randomized controlled trial and enrolled 500 HIV-negative men aged 18–49 years at 3 clinics. Participants were randomized to 1 of 2 study arms (Standard Sizing arm vs Modified Sizing arm) in a 1:1 ratio. All 14 adult ShangRing sizes (40–26 mm inner diameter, each varying by 1 mm) were available in the Standard Sizing arm; the Modified Sizing arm used every other size (40, 38, 36, 34, 32, 30, 28 mm inner diameter). Each participant was scheduled for 2 follow-up visits: the removal visit (day 7 after placement) and the healing check visit (day 42 after placement), when they were evaluated for adverse events (AEs), pain, and healing. Results: Four hundred and ninety-six men comprised the analysis population, with 255 in the Standard Sizing arm and 241 in the Modified Sizing arm. Three men experienced a moderate or severe AEs (0.6%), including 2 in the Standard Sizing arm (0.8%) and 1 in the Modified Sizing arm (0.4%). 73.2% of participants were completely healed at the scheduled day 42 healing check visit, with similar percentages across study arms. Virtually all (99.6%) men, regardless of study arm, stated that they were very satisfied or satisfied with the appearance of their circumcised penis, and 98.6% stated that they would recommend ShangRing circumcision to family/friends. Conclusions: The moderate/severe AE rate was low and similar in the 2 study arms, suggesting that provision of one-half the number of adult device sizes is sufficient for safe service delivery. Effectiveness, time to healing, and acceptability were similar in the study arms. The simplicity of the ShangRing technique, and its relative speed, could facilitate VMMC program goals. In addition, sufficiency of fewer device sizes would simplify logistics and inventory.
Collapse
|
5
|
Ndagijimana A, Mugenzi P, Thomson DR, Hedt-Gauthier B, Condo JU, Ngoga E. PrePex Male Circumcision: Follow-Up and Outcomes during the First Two Years of Implementation at the Rwanda Military Hospital. PLoS One 2015; 10:e0138287. [PMID: 26398343 PMCID: PMC4580619 DOI: 10.1371/journal.pone.0138287] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2015] [Accepted: 08/28/2015] [Indexed: 11/25/2022] Open
Abstract
Background PrePex Male Circumcision (MC) has been demonstrated as an effective and scalable strategy to prevent HIV infection in low- and middle-income countries. This study describes the follow-up and outcomes of clients who underwent PrePex MC between January 2011 and December 2012 with weekly follow-up at the Rwanda Military Hospital, the first national hospital in Rwanda to adopt PrePex. Methods Data on570 clients age 21 to 54 were extracted from patient records. We compared socio-demographic and clinical characteristics, the operator's qualification, HIV status, pain before and after device removal, urological status, device size and follow-up time between clients who were formally discharged and those who defaulted. We reported bivariate associations between each covariate and discharge status, number of people with adverse events by discharge status, and time to formal discharge or defaulting using life table methods. Data were entered into Epidata and analyzed with Stata v13. Results Among study participants, 96.5% were circumcised by non-physician operators, 85.4%were under 30years, 98.9% were HIV-negative and 97.9% were without any urological problems that could delay the healing time. Most (70.7%) defaulted before formal discharge. Pain before (p<0.001) and after PrePex device removal (p = 0.001) were associated with discharge status, although very few cases were reported, and pain was more commonly missing among defaulters. Twenty-seven adverse events were reported (7 formally discharged, 20 defaulters). Median follow-up time was seven weeks among formally discharged and six weeks among defaulters (p<0.001). Conclusion Given that all socio-demographic and most clinical characteristics were not associated with defaulting, we hypothesize that clients stopped returning once they determined they were healed. We recommend less frequent follow-up protocols to encourage clinical visits until formal discharge. Based on these results and recommendations, we believe PrePex MC is a practical circumcision strategy in Rwanda and in sub-Saharan Africa.
Collapse
Affiliation(s)
- Albert Ndagijimana
- University of Rwanda College of Medicine and Health Sciences School of Public Health, Kigali, Rwanda
| | | | - Dana R Thomson
- University of Rwanda College of Medicine and Health Sciences School of Public Health, Kigali, Rwanda; Department of Global Health and Social Medicine, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Bethany Hedt-Gauthier
- University of Rwanda College of Medicine and Health Sciences School of Public Health, Kigali, Rwanda; Department of Global Health and Social Medicine, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Jeanine U Condo
- University of Rwanda College of Medicine and Health Sciences School of Public Health, Kigali, Rwanda
| | | |
Collapse
|
6
|
Cao D, Liu L, Hu Y, Wang J, Yuan J, Dong Q, Wei Q. A systematic review and meta-analysis of circumcision with Shang Ring vs conventional circumcision. Urology 2015; 85:799-804. [PMID: 25711156 DOI: 10.1016/j.urology.2014.12.007] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2014] [Revised: 12/04/2014] [Accepted: 12/05/2014] [Indexed: 02/05/2023]
Abstract
Herein, we conduct a systematic review and meta-analysis of the current evidence to compare the safety and efficacy of Shang Ring circumcision (SRC) with conventional circumcision (CC) for male patients. Articles were searched by 2 independent reviewers. Overall, 8 randomized controlled trials involving 3314 patients were included. Compared with the CC group, SRC is associated with shorter operative time, lower intraoperative pain score, higher satisfaction with penile appearances, less intraoperative blood loss, lower adverse event rate, and lower wound bleeding rate. SRC appears to be a safer and more effective choice in comparison with CC for male patients.
Collapse
Affiliation(s)
- Dehong Cao
- Department of Urology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Liangren Liu
- Department of Urology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Yingchun Hu
- Department of Geriatrics, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Jia Wang
- Department of Urology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Jiuhong Yuan
- Department of Urology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Qiang Dong
- Department of Urology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Qiang Wei
- Department of Urology, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
| |
Collapse
|