Suzuki M, Morita S, Goto Y, Tadenuma H, Nishina Y, Yoneyama M, Tanaka I, Sakai S. Artifact-robust diffusion-weighted whole-body imaging with background suppression at 3 T using improved turbo spin-echo diffusion-weighted imaging.
Br J Radiol 2018;
92:20180489. [PMID:
30407840 DOI:
10.1259/bjr.20180489]
[Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE:
To compare single-shot turbo spin-echo (TSE) diffusion-weighted whole-body imaging with background suppression (DWIBS) and echo-planar imaging (EPI) DWIBS to determine the feasibility of direct-coronal TSE-DWIBS.
METHODS:
All measurements were performed using a 3.0 T MRI scanner. In the phantom study, we compared the contrast ratios (CRs) of tumor-mimicking phantom (tumor) to muscle-mimicking phantom (muscle) and water to muscle and the signal-to-noise ratio (SNR) between TSE-DWIBS and EPI-DWIBS. In the volunteer study, 10 healthy volunteers were whole-body scanned with direct-coronal TSE-DWIBS, direct-coronal EPI-DWIBS (corEPI-DWIBS), and transverse EPI-DWIBS (traEPI-DWIBS). Two radiologists assessed the image distortion, uniformity of fat suppression, overall artifacts, and overall image quality in maximum intensity projection (MIP) images from each DWIBS image using a 5-point scale.
RESULTS:
In the phantom study, the CR of tumor to muscle was found to be lower for TSE-DWIBS (10.57 ± 0.45) than for EPI-DWIBS (15.38 ± 0.27), and the CR of water to muscle was higher for TSE-DWIBS (9.61 ± 0.66) than for EPI-DWIBS (2.52 ± 0.60). The volunteer study revealed good inter observer agreement between TSE-DWIBS and EPI-DWIBS with respect to image distortion, uniformity of fat suppression, overall artifacts, and overall image quality, with weighted Cohen's κ coefficients of 0.91, 0.74, 0.87, and 0.72, respectively. Qualitative analysis scores for image distortion, uniformity of fat suppression, overall artifacts, and overall image quality were significantly higher for TSE-DWIBS than for corEPI-DWIBS or traEPI-DWIBS (p < 0.05).
CONCLUSION:
Direct-coronal TSE-DWIBS is robust against magnetic field inhomogeneity. High-quality images without distortion or fat suppression inhomogeneity were obtained.
ADVANCES IN KNOWLEDGE:
Many studies on DWIBS have been previously reported; however, these studies used EPI read-out. To the best of our knowledge, no studies using TSE read-out have been reported. In this study, we examined the feasibility of TSE-DWIBS with lesser artifacts than EPI-DWIBS.