1
|
Hasse FC, Giannakis A, Wehrse E, Stiller W, Wallwiener M, Kauczor HU, Weber TF, Heil J, Mokry T. Improvement of Breast Cancer Detection Using Dual-Layer Spectral CT. Diagnostics (Basel) 2024; 14:1560. [PMID: 39061697 PMCID: PMC11275589 DOI: 10.3390/diagnostics14141560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2024] [Revised: 07/04/2024] [Accepted: 07/15/2024] [Indexed: 07/28/2024] Open
Abstract
This study aimed to investigate the diagnostic performance of breast mass detection on monoenergetic image data at 40 keV (MonoE40) and on iodine maps (IM) compared with conventional image data (CI). In this prospective single-center case-control study, 50 breast cancer patients were examined using contrast-enhanced dual-layer spectral CT. For qualitative and quantitative comparison of MonoE40 and IM with CI image data, four blinded, independent readers assessed 300 randomized single slices (two slices for each imaging type per case) with or without cancerous lesions for the presence of a breast mass. Detection sensitivity and specificity were calculated and readers rated their subjective diagnostic certainty. For statistical analysis of sensitivity and specificity, a paired t-test and ANOVA were used (significance level p = 0.05). A total of 50 female patients (median age 51 years, range 28-83 years) participated. IM had the highest overall scores in sensitivity and specificity for breast cancer detection, with 0.97 ± 0.06 and 0.95 ± 0.07, respectively, compared with 0.90 ± 0.04 and 0.92 ± 0.06 in CI. MonoE40 yielded a sensitivity of 0.96 ± 0.02 and specificity of 0.94 ± 0.08. All differences in sensitivity and specificity between MonoE or IM and CI were statistically significant (p < 0.001). The superiority of IM sensitivity and specificity was most pronounced in patients with dense breasts. Spectral CT improved the detection of breast cancer with higher sensitivity and specificity compared to conventional image data in our study.
Collapse
Affiliation(s)
- Felix Christian Hasse
- Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany (T.F.W.)
| | - Athanasios Giannakis
- Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany (T.F.W.)
| | - Eckhard Wehrse
- Division of Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
| | - Wolfram Stiller
- Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany (T.F.W.)
| | - Markus Wallwiener
- Department of Obstetrics and Gynecology, Heidelberg University Hospital, Im Neuenheimer Feld 440, 69120 Heidelberg, Germany
| | - Hans-Ulrich Kauczor
- Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany (T.F.W.)
| | - Tim F. Weber
- Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany (T.F.W.)
| | - Jörg Heil
- Heidelberg Breast Centre St. Elisabeth Clinic, Max-Reger-Straße 5, 69121 Heidelberg, Germany
| | - Theresa Mokry
- Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany (T.F.W.)
- Division of Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
| |
Collapse
|
2
|
Euler A, Wullschleger S, Sartoretti T, Müller D, Keller EX, Lavrek D, Donati O. Dual-energy CT kidney stone characterization-can diagnostic accuracy be achieved at low radiation dose? Eur Radiol 2023; 33:6238-6244. [PMID: 36988716 PMCID: PMC10415460 DOI: 10.1007/s00330-023-09569-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 01/11/2023] [Accepted: 02/07/2023] [Indexed: 03/30/2023]
Abstract
OBJECTIVES To assess the accuracy of low-dose dual-energy computed tomography (DECT) to differentiate uric acid from non-uric acid kidney stones in two generations of dual-source DECT with stone composition analysis as the reference standard. METHODS Patients who received a low-dose unenhanced DECT for the detection or follow-up of urolithiasis and stone extraction with stone composition analysis between January 2020 and January 2022 were retrospectively included. Collected stones were characterized using X-ray diffraction. Size, volume, CT attenuation, and stone characterization were assessed using DECT post-processing software. Characterization as uric acid or non-uric acid stones was compared to stone composition analysis as the reference standard. Sensitivity, specificity, and accuracy of stone classification were computed. Dose length product (DLP) and effective dose served as radiation dose estimates. RESULTS A total of 227 stones in 203 patients were analyzed. Stone composition analysis identified 15 uric acid and 212 non-uric acid stones. Mean size and volume were 4.7 mm × 2.8 mm and 114 mm3, respectively. CT attenuation of uric acid stones was significantly lower as compared to non-uric acid stones (p < 0.001). Two hundred twenty-five of 227 kidney stones were correctly classified by DECT. Pooled sensitivity, specificity, and accuracy were 1.0 (95%CI: 0.97, 1.00), 0.93 (95%CI: 0.68, 1.00), and 0.99 (95%CI: 0.97, 1.00), respectively. Eighty-two of 84 stones with a diameter of ≤ 3 mm were correctly classified. Mean DLP was 162 ± 57 mGy*cm and effective dose was 2.43 ± 0.86 mSv. CONCLUSIONS Low-dose dual-source DECT demonstrated high accuracy to discriminate uric acid from non-uric acid stones even at small stone sizes. KEY POINTS • Two hundred twenty-five of 227 stones were correctly classified as uric acid vs. non-uric acid stones by low-dose dual-energy CT with stone composition analysis as the reference standard. • Pooled sensitivity, specificity, and accuracy for stone characterization were 1.0, 0.93, and 0.99, respectively. • Low-dose dual-energy CT for stone characterization was feasible in the majority of small stones < 3 mm.
Collapse
Affiliation(s)
- André Euler
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091, Zurich, Switzerland.
| | - Sara Wullschleger
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091, Zurich, Switzerland
| | - Thomas Sartoretti
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091, Zurich, Switzerland
| | - Daniel Müller
- Institute of Clinical Chemistry, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091, Zurich, Switzerland
| | - Etienne Xavier Keller
- Department of Urology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Dejan Lavrek
- Department of Urology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Olivio Donati
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091, Zurich, Switzerland
| |
Collapse
|
3
|
Perrella A, Bagnacci G, Di Meglio N, Di Martino V, Mazzei MA. Thoracic Diseases: Technique and Applications of Dual-Energy CT. Diagnostics (Basel) 2023; 13:2440. [PMID: 37510184 PMCID: PMC10378112 DOI: 10.3390/diagnostics13142440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 07/06/2023] [Accepted: 07/07/2023] [Indexed: 07/30/2023] Open
Abstract
Dual-energy computed tomography (DECT) is one of the most promising technological innovations made in the field of imaging in recent years. Thanks to its ability to provide quantitative and reproducible data, and to improve radiologists' confidence, especially in the less experienced, its applications are increasing in number and variety. In thoracic diseases, DECT is able to provide well-known benefits, although many recent articles have sought to investigate new perspectives. This narrative review aims to provide the reader with an overview of the applications and advantages of DECT in thoracic diseases, focusing on the most recent innovations. The research process was conducted on the databases of Pubmed and Cochrane. The article is organized according to the anatomical district: the review will focus on pleural, lung parenchymal, breast, mediastinal, lymph nodes, vascular and skeletal applications of DECT. In conclusion, considering the new potential applications and the evidence reported in the latest papers, DECT is progressively entering the daily practice of radiologists, and by reading this simple narrative review, every radiologist will know the state of the art of DECT in thoracic diseases.
Collapse
Affiliation(s)
- Armando Perrella
- Unit of Diagnostic Imaging, Department of Medical, Surgical and Neuro Sciences and of Radiological Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, 53100 Siena, Italy
| | - Giulio Bagnacci
- Unit of Diagnostic Imaging, Department of Medical, Surgical and Neuro Sciences and of Radiological Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, 53100 Siena, Italy
| | - Nunzia Di Meglio
- Unit of Diagnostic Imaging, Department of Medical, Surgical and Neuro Sciences and of Radiological Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, 53100 Siena, Italy
| | - Vito Di Martino
- Unit of Diagnostic Imaging, Department of Medical, Surgical and Neuro Sciences and of Radiological Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, 53100 Siena, Italy
| | - Maria Antonietta Mazzei
- Unit of Diagnostic Imaging, Department of Medical, Surgical and Neuro Sciences and of Radiological Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, 53100 Siena, Italy
| |
Collapse
|
4
|
Guerrini S, Bagnacci G, Perrella A, Meglio ND, Sica C, Mazzei MA. Dual Energy CT in Oncology: Benefits for Both Patients and Radiologists From an Emerging Quantitative and Functional Diagnostic Technique. Semin Ultrasound CT MR 2023; 44:205-213. [PMID: 37245885 DOI: 10.1053/j.sult.2023.03.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Dual-energy CT (DECT) imaging makes it possible to identify the characteristics of materials that cannot be recognized with conventional single-energy CT (SECT). In the postprocessing study phase, virtual monochromatic images and virtual-non-contrast (VNC) images, also permits reduction of dose exposure by eliminating the precontrast acquisition scan. Moreover, in virtual monochromatic images, the iodine contrast increases when the energy level decreases resulting in better visualization of hypervascular lesions and in a better tissue contrast between hypovascular lesions and the surrounding parenchyma; thus, allowing for reduction of required iodinate contrast material, especially important in patients with renal impairment. All these advantages are particularly important in oncology, providing the possibility of overcoming many SECT imaging limits and making CT examinations safer and more feasible in critical patients. This review explores the basis of DECT imaging and its utility in routine oncologic clinical practice, with particular attention to the benefits of this technique for both the patients and the radiologists.
Collapse
Affiliation(s)
- Susanna Guerrini
- Unit of Diagnostic Imaging, Department of Medical Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, Siena, Italy.
| | - Giulio Bagnacci
- Diagnostic Imaging Unit, Department of Diagnostic Imaging, Azienda USL-Toscana Sud-Est, Poggibonsi, Valdelsa, Italy
| | - Armando Perrella
- Diagnostic Imaging Unit, Department of Diagnostic Imaging, Azienda USL-Toscana Sud-Est, Grosseto, Italy
| | - Nunzia Di Meglio
- Unit of Diagnostic Imaging, Department of Medical Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| | - Cristian Sica
- Unit of Diagnostic Imaging, Department of Medical, Surgical and Neuro Sciences and of Medical Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| | - Maria Antonietta Mazzei
- Unit of Diagnostic Imaging, Department of Medical, Surgical and Neuro Sciences and of Medical Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| |
Collapse
|
5
|
Galluzzo A, Danti G, Bicci E, Mastrorosato M, Bertelli E, Miele V. The role of Dual-Energy CT in the study of urinary tract tumours: review of recent literature. Semin Ultrasound CT MR 2023; 44:136-144. [DOI: 10.1053/j.sult.2023.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/09/2023]
|
6
|
Borges AP, Antunes C, Curvo-Semedo L. Pros and Cons of Dual-Energy CT Systems: "One Does Not Fit All". Tomography 2023; 9:195-216. [PMID: 36828369 PMCID: PMC9964233 DOI: 10.3390/tomography9010017] [Citation(s) in RCA: 18] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 01/22/2023] [Accepted: 01/23/2023] [Indexed: 01/31/2023] Open
Abstract
Dual-energy computed tomography (DECT) uses different energy spectrum x-ray beams for differentiating materials with similar attenuation at a certain energy. Compared with single-energy CT, it provides images with better diagnostic performance and a potential reduction of contrast agent and radiation doses. There are different commercially available DECT technologies, with machines that may display two x-ray sources and two detectors, a single source capable of fast switching between two energy levels, a specialized detector capable of acquiring high- and low-energy data sets, and a filter splitting the beam into high- and low-energy beams at the output. Sequential acquisition at different tube voltages is an alternative approach. This narrative review describes the DECT technique using a Q&A format and visual representations. Physical concepts, parameters influencing image quality, postprocessing methods, applicability in daily routine workflow, and radiation considerations are discussed. Differences between scanners are described, regarding design, image quality variabilities, and their advantages and limitations. Additionally, current clinical applications are listed, and future perspectives for spectral CT imaging are addressed. Acknowledging the strengths and weaknesses of different DECT scanners is important, as these could be adapted to each patient, clinical scenario, and financial capability. This technology is undoubtedly valuable and will certainly keep improving.
Collapse
Affiliation(s)
- Ana P. Borges
- Medical Imaging Department, Coimbra University Hospitals, 3004-561 Coimbra, Portugal
- Faculty of Medicine, University of Coimbra, 3000-370 Coimbra, Portugal
- Academic and Clinical Centre of Coimbra, 3000-370 Coimbra, Portugal
- Correspondence:
| | - Célia Antunes
- Medical Imaging Department, Coimbra University Hospitals, 3004-561 Coimbra, Portugal
- Academic and Clinical Centre of Coimbra, 3000-370 Coimbra, Portugal
| | - Luís Curvo-Semedo
- Medical Imaging Department, Coimbra University Hospitals, 3004-561 Coimbra, Portugal
- Faculty of Medicine, University of Coimbra, 3000-370 Coimbra, Portugal
- Academic and Clinical Centre of Coimbra, 3000-370 Coimbra, Portugal
| |
Collapse
|
7
|
Dell’Aversana S, Ascione R, De Giorgi M, De Lucia DR, Cuocolo R, Boccalatte M, Sibilio G, Napolitano G, Muscogiuri G, Sironi S, Di Costanzo G, Cavaglià E, Imbriaco M, Ponsiglione A. Dual-Energy CT of the Heart: A Review. J Imaging 2022; 8:jimaging8090236. [PMID: 36135402 PMCID: PMC9503750 DOI: 10.3390/jimaging8090236] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 08/09/2022] [Accepted: 08/30/2022] [Indexed: 11/26/2022] Open
Abstract
Dual-energy computed tomography (DECT) represents an emerging imaging technique which consists of the acquisition of two separate datasets utilizing two different X-ray spectra energies. Several cardiac DECT applications have been assessed, such as virtual monoenergetic images, virtual non-contrast reconstructions, and iodine myocardial perfusion maps, which are demonstrated to improve diagnostic accuracy and image quality while reducing both radiation and contrast media administration. This review will summarize the technical basis of DECT and review the principal cardiac applications currently adopted in clinical practice, exploring possible future applications.
Collapse
Affiliation(s)
- Serena Dell’Aversana
- Department of Radiology, Santa Maria delle Grazie Hospital, ASL Napoli 2 Nord, 80078 Pozzuoli, Italy
- Correspondence:
| | - Raffaele Ascione
- Department of Advanced Biomedical Sciences, University of Naples Federico II, 80131 Naples, Italy
| | - Marco De Giorgi
- Department of Advanced Biomedical Sciences, University of Naples Federico II, 80131 Naples, Italy
| | - Davide Raffaele De Lucia
- Department of Advanced Biomedical Sciences, University of Naples Federico II, 80131 Naples, Italy
| | - Renato Cuocolo
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Baronissi, Italy
| | - Marco Boccalatte
- Coronary Care Unit, Santa Maria delle Grazie Hospital, ASL Napoli 2 Nord, 80078 Pozzuoli, Italy
| | - Gerolamo Sibilio
- Coronary Care Unit, Santa Maria delle Grazie Hospital, ASL Napoli 2 Nord, 80078 Pozzuoli, Italy
| | | | - Giuseppe Muscogiuri
- Department of Radiology, Istituto Auxologico Italiano IRCCS, San Luca Hospital, University Milano Bicocca, 20149 Milan, Italy
| | - Sandro Sironi
- Department of Radiology, Istituto Auxologico Italiano IRCCS, San Luca Hospital, University Milano Bicocca, 20149 Milan, Italy
| | - Giuseppe Di Costanzo
- Department of Radiology, Santa Maria delle Grazie Hospital, ASL Napoli 2 Nord, 80078 Pozzuoli, Italy
| | - Enrico Cavaglià
- Department of Radiology, Santa Maria delle Grazie Hospital, ASL Napoli 2 Nord, 80078 Pozzuoli, Italy
| | - Massimo Imbriaco
- Department of Advanced Biomedical Sciences, University of Naples Federico II, 80131 Naples, Italy
| | - Andrea Ponsiglione
- Department of Advanced Biomedical Sciences, University of Naples Federico II, 80131 Naples, Italy
| |
Collapse
|
8
|
Lubner MG, Ziemlewicz TJ, Wells SA, Li K, Wu PH, Hinshaw JL, Lee FT, Brace CL. Advanced CT techniques for hepatic microwave ablation zone monitoring and follow-up. Abdom Radiol (NY) 2022; 47:2658-2668. [PMID: 34731282 DOI: 10.1007/s00261-021-03333-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Revised: 10/21/2021] [Accepted: 10/22/2021] [Indexed: 01/18/2023]
Abstract
PURPOSE To evaluate utility of advanced CT techniques including HighlY constrained back-projection and dual-energy CT for intra- and post-procedure hepatic microwave ablation zone monitoring. METHODS 8 hepatic microwave ablations were performed in 4 adult swine (5 min/65 W). Low-dose routine CECT and dual-energy CT images were obtained every 1 min during ablation. Images were reconstructed ± HYPR. Image quality and dose metrics were collected. 21 MWA were performed in 4 adult swine. Immediate post-procedure CECT was performed in the arterial, portal venous, and delayed phases using both routine and DECT imaging with full-dose weight-based IV contrast dosing. An additional 16 MWA were subsequently performed in 2 adult swine. Immediate post-procedure CT was performed with half-dose IV contrast using routine and DECT. 12 patients (10 M/2F, mean age 62.4 yrs) with 14 hepatic tumors (4 HCC, 10 metastatic lesions) treated with MWA were prospectively imaged with DECT 1 month post-procedure. 120 kV equivalent images were compared to DECT [51 keV, iodine material density]. Image quality and dose metrics were collected. RESULTS Gas created during MWA led to high CNR in all intraprocedural CT datasets. Optimal CNRs were noted at 4 min with CNR 6.7, 15.5,15.9, and 21.5 on LD-CECT, LD-CECT + HYPR, DECT, and DECT + HYPR, respectively (p < 0.001). Image quality scores at 4 min were 1.8, 2.8, 2.4, and 3, respectively (p < 0.001). Mean radiation dose (CTDIvol) was eightfold higher for the DECT series. For swine, post-procedural DECT images (IMD/51 keV) showed improved CNR compared to routine CT at all time points with full and with reduced dose contrast (CNR 4.6, 3.2, and 1.5, respectively, at half-contrast dose, p < 0.001). For human subjects, the 51 keV and IMD images showed higher CNRs (5.8, 4.8 vs 4.0, p < 0.001) and SNRs (3.7, 5.9 vs 2.8). Ablation zone sharpness was improved with DECT (routine 3.0 ± 0.7, DECT 3.5 ± 0.5). Diagnostic confidence was higher with DECT (routine 2.3 ± 0.9, DECT 2.6 ± 0.8). Mean DLP for DECT was 905.7 ± 606 mGy-cm, CTDIvol 37.5 ± 21.2 mGy, and effective dose 13.6 ± 9.1 mSv, slightly higher than conventional CT series. CONCLUSION Advanced CT techniques can improve CT image quality in peri-procedural hepatic microwave ablation zone evaluation.
Collapse
Affiliation(s)
- Meghan G Lubner
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA.
| | - Timothy J Ziemlewicz
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA
| | - Shane A Wells
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA
| | - Ke Li
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
| | - Po-Hung Wu
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA
- Department of Biomedical and Electrical Engineering, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
- Department of Electrical and Computer Engineering, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
| | - J Louis Hinshaw
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA
| | - Fred T Lee
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA
| | - Chris L Brace
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
- Department of Biomedical and Electrical Engineering, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
| |
Collapse
|
9
|
Dual-energy CT of acute bowel ischemia. Abdom Radiol (NY) 2022; 47:1660-1683. [PMID: 34191075 DOI: 10.1007/s00261-021-03188-4] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Revised: 06/17/2021] [Accepted: 06/18/2021] [Indexed: 12/17/2022]
Abstract
Acute bowel ischemia is a condition with high mortality and requires rapid intervention to avoid catastrophic outcomes. Swift and accurate imaging diagnosis is essential because clinical findings are commonly nonspecific. Conventional contrast enhanced CT of the abdomen has been the imaging modality of choice to evaluate suspected acute bowel ischemia. However, subtlety of image findings and lack of non-contrast or arterial phase images can make correct diagnosis challenging. Dual-energy CT provides valuable information toward assessing bowel ischemia. Dual-energy CT exploits the differential X-ray attenuation at two different photon energy levels to characterize the composition of tissues and reveal the presence or absence of faint intravenous iodinated contrast to improve reader confidence in detecting subtle bowel wall enhancement. With the same underlying technique, virtual non-contrast images can help to show non-enhancing hyperdense hemorrhage of the bowel wall in intravenous contrast-enhanced scans without the need to acquire actual non-contrast scans. Dual-energy CT derived low photon energy (keV) virtual monoenergetic images emphasize iodine contrast and provide CT angiography-like images from portal venous phase scans to better evaluate abdominal arterial patency. In Summary, dual-energy CT aids diagnosing acute bowel ischemia in multiple ways, including improving visualization of the bowel wall and mesenteric vasculature, revealing intramural hemorrhage in contrast enhanced scans, or possibly reducing intravenous contrast dose.
Collapse
|
10
|
Bicci E, Mastrorosato M, Danti G, Lattavo L, Bertelli E, Cozzi D, Pradella S, Agostini S, Miele V. Dual-Energy CT applications in urinary tract cancers: an update. TUMORI JOURNAL 2022; 109:148-156. [PMID: 35442120 DOI: 10.1177/03008916221088883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Urothelial tumours are the fourth most common cancer in the world and account for the majority of tumours involving the bladder. The symptom that often leads to diagnosis is the presence of haematuria. Diagnosis is made by cystoscopy, which is currently the gold standard in bladder cancer. Computed tomography (CT) performed with pre- and post-contrastographic phases is essential in order to assess the loco-regional and distant extension of disease. The diagnosis and staging of upper tract urothelial cancer (UTUC) are best done with computed tomography urography and flexible ureteroscopy (URS). In the acquisition protocol of this type of tumour, a urographic phase is mandatory, which allows for an accurate diagnostic assessment of the renal pelvis, ureter and bladder, especially in papillary forms. The use of multiple acquisition phases, especially in this type of patient who will have to perform follow-up CTs, leads to the problem of overexposure to ionising radiation, as well as the frequent administration of iodinated contrast medium. For this reason, in recent year, the focus has been put on advanced technologies such as dual-energy CT (DECT), that is a method that can offer some advantages for both radiologist and patient, in the diagnosis of cancer and, in particular, urinary tract disease.
Collapse
Affiliation(s)
- Eleonora Bicci
- Department of Radiology, Careggi University Hospital, Florence, Italy
| | | | - Ginevra Danti
- Department of Radiology, Careggi University Hospital, Florence, Italy
| | - Lorenzo Lattavo
- Department of Radiology, Careggi University Hospital, Florence, Italy
| | - Elena Bertelli
- Department of Radiology, Careggi University Hospital, Florence, Italy
| | - Diletta Cozzi
- Department of Radiology, Careggi University Hospital, Florence, Italy
| | - Silvia Pradella
- Department of Radiology, Careggi University Hospital, Florence, Italy
| | - Simone Agostini
- Department of Radiology, Careggi University Hospital, Florence, Italy
| | - Vittorio Miele
- Department of Radiology, Careggi University Hospital, Florence, Italy
| |
Collapse
|
11
|
Wagner PP, Roux JP, Chuzel Q, Szulc P, Bermond F, Duboeuf F, Chapurlat R, Follet H, Pialat JB. Dual-energy CT hybridation and kernel processing effects on the estimation of bone mineral mass and density: a calcination study on ex vivo human femur. Osteoporos Int 2022; 33:909-920. [PMID: 34837503 DOI: 10.1007/s00198-021-06210-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 10/14/2021] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Recent technological advances with dual-energy quantitative computed tomography (DEQCT) allow to combine two images of different level of energy to obtain simulated mono-energetic images at 60 keV (SIM60KeV-QCT) with improved image contrast in clinical practice. This study includes three topics: (1) compare bone mineral content (BMC), areal and volumetric bone mineral density (aBMD, vBMD) obtained with SIM60KeV-QCT, single-energy QCT (SEQCT), and dual X-ray absorptiometry (DXA); (2) compare ash density and weight with respective vBMD and BMC assessed on SIM60KeV-QCT, SEQCT, and DXA; and (3) compare the influence of reconstruction kernels on the accuracy of vBMD and BMC using ash density and ash weight as the reference values. METHODS DXA, SEQCT, and DEQCT acquisitions were performed ex vivo on 42 human femurs. Standard kernel (SK) and bone kernel (BK) were applied to each stack of images. Ten diaphyses and 10 femoral necks were cut, scanned, and reconstructed using the techniques described above. Finally, the bone specimens were calcined to obtain the ash weight. RESULTS QCT analysis (SEQCT, SIM60KeV-QCT) underestimated BMC value compared to DXA. For femoral necks, all QCT analyses provided an unbiased estimate of ash weight but underestimated ash density regardless of the kernel used. For femoral diaphysis, SEQCT BK, SIM60KeV-QCT BK, and SK underestimated ash weight but not ash density. CONCLUSION BMC and vBMD quantifications with the SIM60KeV-QCT gave similar results as the SEQCT. Further studies are needed to optimize the use of SIM60KeV-QCT in clinical situations. SK should be used given the effect of kernels on QCT assessment.
Collapse
Affiliation(s)
- Philippe Paul Wagner
- Univ Lyon, Université Claude Bernard Lyon 1, INSERM, LYOS UMR1033, 69008, Lyon, France
| | - Jean-Paul Roux
- Univ Lyon, Université Claude Bernard Lyon 1, INSERM, LYOS UMR1033, 69008, Lyon, France
| | - Quentin Chuzel
- Department of Radiology, Hospices Civils de Lyon, Hôpital Edouard Herriot, 69437, Lyon, France
| | - Pawel Szulc
- Univ Lyon, Université Claude Bernard Lyon 1, INSERM, LYOS UMR1033, 69008, Lyon, France
| | - François Bermond
- Univ Lyon, Université Claude Bernard Lyon 1, Univ Gustave Eiffel, LBMC UMR_T 9406, Lyon, France
| | - François Duboeuf
- Univ Lyon, Université Claude Bernard Lyon 1, INSERM, LYOS UMR1033, 69008, Lyon, France
| | - Roland Chapurlat
- Univ Lyon, Université Claude Bernard Lyon 1, INSERM, LYOS UMR1033, 69008, Lyon, France
- Department of Rheumatology, Hospices Civils de Lyon, Hôpital Edouard Herriot, 69437, Lyon, France
| | - Hélène Follet
- Univ Lyon, Université Claude Bernard Lyon 1, INSERM, LYOS UMR1033, 69008, Lyon, France
| | - Jean-Baptiste Pialat
- Univ Lyon, Université Claude Bernard Lyon 1, INSERM, LYOS UMR1033, 69008, Lyon, France.
- Department of Radiology, Hospices Civils de Lyon, Hôpital Edouard Herriot, 69437, Lyon, France.
- Department of Radiology, Hospices Civils de Lyon, Service de Radiologie, Centre Hospitalier Lyon-Sud, 165 Chemin du Grand Revoyet 69310, Pierre-Bénite, France.
| |
Collapse
|
12
|
Marri UK, Madhusudhan KS. Dual-Energy Computed Tomography in Diffuse Liver Diseases. JOURNAL OF GASTROINTESTINAL AND ABDOMINAL RADIOLOGY 2022. [DOI: 10.1055/s-0042-1742432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
AbstractDual-energy computed tomography (DECT) is an advancement in the field of CT, where images are acquired at two energies. Materials are identified and quantified based on their attenuation pattern at two different energy beams using various material decomposition algorithms. With its ability to identify and quantify materials such as fat, calcium, iron, and iodine, DECT adds great value to conventional CT and has innumerable applications in body imaging. Continuous technological advances in CT scanner hardware, material decomposition algorithms, and image reconstruction software have led to considerable growth of these applications. Among all organs, the liver is the most widely investigated by DECT, and DECT has shown promising results in most liver applications. In this article, we aim to provide an overview of the role of DECT in the assessment of diffuse liver diseases, mainly the deposition of fat, fibrosis, and iron and review the most relevant literature.
Collapse
Affiliation(s)
- Uday Kumar Marri
- Department of Radiodiagnosis and Interventional Radiology, All India Institute of Medical Sciences, New Delhi, India
| | - Kumble Seetharama Madhusudhan
- Department of Radiodiagnosis and Interventional Radiology, All India Institute of Medical Sciences, New Delhi, India
| |
Collapse
|
13
|
Tarkowski P, Czekajska-Chehab E. Dual-Energy Heart CT: Beyond Better Angiography-Review. J Clin Med 2021; 10:jcm10215193. [PMID: 34768713 PMCID: PMC8584316 DOI: 10.3390/jcm10215193] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 11/02/2021] [Accepted: 11/04/2021] [Indexed: 12/30/2022] Open
Abstract
Heart CT has undergone substantial development from the use of calcium scores performed on electron beam CT to modern 256+-row CT scanners. The latest big step in its evolution was the invention of dual-energy scanners with much greater capabilities than just performing better ECG-gated angio-CT. In this review, we present the unique features of dual-energy CT in heart diagnostics.
Collapse
|
14
|
Yoo J, Lee JM, Yoon JH, Joo I, Lee ES, Jeon SK, Jang S. Comparison of low kVp CT and dual-energy CT for the evaluation of hypervascular hepatocellular carcinoma. Abdom Radiol (NY) 2021; 46:3217-3226. [PMID: 33713160 DOI: 10.1007/s00261-020-02888-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 11/25/2020] [Accepted: 11/27/2020] [Indexed: 01/19/2023]
Abstract
PURPOSE To compare lesion conspicuity and image quality of arterial phase images obtained from low kVp (90-kVp) and dual-energy (DE) scans for the evaluation of hypervascular hepatocellular carcinoma (HCC). METHODS This retrospective study included 229 patients with HCC who underwent either 90 kVp (n = 106) or DE scan (80- and 150-kVp with a tin filter) (n = 123) during the arterial phase. DE scans were reconstructed into a linearly blended image with a mixed ratio of 0.6 (60% 80kVp and 40% 150 kVp) and post-processed for 40 keV and 50 keV images. The contrast-to-noise ratio (CNR) of HCC to the liver and image noise was measured. Lesion conspicuity, liver parenchymal image quality, and overall image preference were assessed qualitatively by three independent radiologists. RESULTS DE 40 keV images had the highest CNR of HCC, and DE blended images had the lowest image noise among four image sets (p = 0.01 and p < 0.001, respectively). There was no significant difference in mean volume CT dose index and dose-length product between DE and low kVp scan (ps > 0.05). For qualitative analyses, DE blended images had the highest scores for image quality and overall image preference (ps < 0.001). CONCLUSION At an equal radiation dose, DE 40 keV showed higher CNR of HCC and DE blended image showed higher image quality and image preference compared with low kVp CT.
Collapse
Affiliation(s)
- Jeongin Yoo
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, Seoul, Korea.
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea.
- Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Daehak-ro 101, Jongno-gu, Seoul, 03080, Korea.
| | - Jeong Hee Yoon
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea
| | - Ijin Joo
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea
| | - Eun Sun Lee
- Department of Radiology, Chung-Ang University Hospital, Seoul, Korea
| | - Sun Kyung Jeon
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Siwon Jang
- Department of Radiology, Seoul National University Boramae Hospital, Seoul, Korea
| |
Collapse
|
15
|
Shang J, Li XH, Lu SQ, Shang Y, Li LL, Liu B. Gout of feet and ankles in different disease durations: diagnostic value of single-source DECT and evaluation of urate deposition with a novel semi-quantitative DECT scoring system. Adv Rheumatol 2021; 61:36. [PMID: 34118994 DOI: 10.1186/s42358-021-00194-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Accepted: 06/02/2021] [Indexed: 12/22/2022] Open
Abstract
OBJECTIVES To investigate the diagnostic performance of single-source dual-energy computed tomography (DECT) based on gemstone spectral imaging technology (including Discovery CT750HD and Revolution CT) in patients with suspected feet/ankles gouty arthritis, and evaluate the urate deposition with a novel semi-quantitative DECT scoring system. METHODS A total of 196 patients were consecutively included. Feet and ankles were evaluated in all patients by single-source DECT scan. The 2015 EULAR/ACR criteria were used as the reference for the diagnosis of gout. The sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) of DECT for the diagnosis of gout in the early (≤1 year), middle (1-3 years), and late (> 3 years) disease durations were calculated. Besides, a novel semi-quantitative DECT scoring system was assessed for the measurement of urate deposition, and the correlation between the scores and the clinical and serological data were also evaluated. Moreover, the influences of artifacts on the diagnostic performance of DECT were also determined. RESULTS The sensitivity, specificity, and AUC of DECT in 196 patients were 38.10, 96.43%, and 0.673 in the early-stage group; 62.96, 100.00%, and 0.815 in the middle-stage group; and 77.55, 87.50%, and 0.825 in the late-stage group, respectively. The overall diagnostic accuracies in the AUC of DECT (Discovery CT750HD and Revolution CT) in the middle and late stages of gout were higher than that in the early stage of gout. Besides, the monosodium urate crystals were deposited on the first metatarsophalangeal joints and ankles/midfeet. Age, the presence of tophus, bone erosion, and disease duration considerably affected the total urate score. No statistical difference in the positive detection of nail artifact, skin artifact, vascular calcification, and noise artifact was found between the case and control groups. CONCLUSION DECT (Discovery CT750HD and Revolution CT) showed promising diagnostic accuracy for the detection of urate crystal deposition in gout but had limited diagnostic sensitivity for short-stage gout. Longer disease duration, the presence of tophus, and bone erosion were associated with the urate crystal score system. The artifacts do not remarkably affect the diagnostic performance of DECT in gout.
Collapse
Affiliation(s)
- Jin Shang
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, 210 Jixi Road, Hefei, 230022, Anhui, China
| | - Xiao-Hu Li
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, 210 Jixi Road, Hefei, 230022, Anhui, China
| | - Shu-Qin Lu
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, 210 Jixi Road, Hefei, 230022, Anhui, China
| | - Yi Shang
- Outpatient Department of The Second Central Division, The General Hospital of PLA, Beijing, 100853, China
| | - Lu-Lu Li
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, 210 Jixi Road, Hefei, 230022, Anhui, China
| | - Bin Liu
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, 210 Jixi Road, Hefei, 230022, Anhui, China.
| |
Collapse
|
16
|
Kayano S. [5. Principles of Dual-energy CT]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2021; 77:515-523. [PMID: 34011795 DOI: 10.6009/jjrt.2021_jsrt_77.5.515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Shingo Kayano
- Department of Radiological Technology, Tohoku University Hospital
| |
Collapse
|
17
|
Gentili F, Guerrini S, Mazzei FG, Monteleone I, Di Meglio N, Sansotta L, Perrella A, Puglisi S, De Filippo M, Gennaro P, Volterrani L, Castagna MG, Dotta F, Mazzei MA. Dual energy CT in gland tumors: a comprehensive narrative review and differential diagnosis. Gland Surg 2020; 9:2269-2282. [PMID: 33447579 DOI: 10.21037/gs-20-543] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Dual energy CT (DECT)with image acquisition at two different photon X-ray levels allows the characterization of a specific tissue or material/elements, the extrapolation of virtual unenhanced and monoenergetic images, and the quantification of iodine uptake; such special capabilities make the DECT the perfect technique to support oncological imaging for tumor detection and characterization and treatment monitoring, while concurrently reducing the dose of radiation and iodine and improving the metal artifact reduction. Even though its potential in the field of oncology has not been fully explored yet, DECT is already widely used today thanks to the availability of different CT technologies, such as dual-source, single-source rapid-switching, single-source sequential, single-source twin-beam and dual-layer technologies. Moreover DECT technology represents the future of the imaging innovation and it is subject to ongoing development that increase according its clinical potentiality, in particular in the field of oncology. This review points out recent state-of-the-art in DECT applications in gland tumors, with special focus on its potential uses in the field of oncological imaging of endocrine and exocrine glands.
Collapse
Affiliation(s)
- Francesco Gentili
- Unit of Diagnostic Imaging, Department of Radiological Sciences, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| | - Susanna Guerrini
- Unit of Diagnostic Imaging, Department of Radiological Sciences, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| | - Francesco Giuseppe Mazzei
- Unit of Diagnostic Imaging, Department of Radiological Sciences, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| | - Ilaria Monteleone
- Unit of Diagnostic Imaging, Department of Medical, Surgical and Neuro Sciences and of Radiological Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| | - Nunzia Di Meglio
- Unit of Diagnostic Imaging, Department of Medical, Surgical and Neuro Sciences and of Radiological Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| | - Letizia Sansotta
- Unit of Diagnostic Imaging, Department of Medical, Surgical and Neuro Sciences and of Radiological Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| | - Armando Perrella
- Unit of Diagnostic Imaging, Department of Medical, Surgical and Neuro Sciences and of Radiological Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| | - Sara Puglisi
- Unit of Radiology, Department of Medicine and Surgery, Azienda Ospedaliero-Universitaria di Parma, Parma, Italy
| | - Massimo De Filippo
- Unit of Radiology, Department of Medicine and Surgery, Azienda Ospedaliero-Universitaria di Parma, Parma, Italy
| | - Paolo Gennaro
- Department of Maxillofacial Surgery, University of Siena, Azienda Ospedaliera Universitaria Senese, Siena, Italy
| | - Luca Volterrani
- Unit of Diagnostic Imaging, Department of Medical, Surgical and Neuro Sciences and of Radiological Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| | - Maria Grazia Castagna
- Unit of Endocrinology, Department of Medical, Surgical and Neuro Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| | - Francesco Dotta
- Unit of Diabetology, Department of Medical, Surgical and Neuro Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| | - Maria Antonietta Mazzei
- Unit of Diagnostic Imaging, Department of Medical, Surgical and Neuro Sciences and of Radiological Sciences, University of Siena, Azienda Ospedaliero-Universitaria Senese, Siena, Italy
| |
Collapse
|
18
|
Duan X, Ananthakrishnan L, Guild JB, Xi Y, Rajiah P. Radiation doses and image quality of abdominal CT scans at different patient sizes using spectral detector CT scanner: a phantom and clinical study. Abdom Radiol (NY) 2020; 45:3361-3368. [PMID: 31587100 DOI: 10.1007/s00261-019-02247-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
PURPOSE To compare radiation dose and image quality for abdominal CTs performed on a spectral detector CT (SDCT) and a comparable single-energy conventional CT scanner for patients of different sizes. METHODS Four semi-anthropomorphic phantoms were scanned on an SDCT (IQon, Philips Healthcare) and a comparable single-energy CT (iCT 256, Philips Healthcare) under matched scan parameters. Image noise and radiation dose were compared. For the HIPAA-compliant, IRB-approved retrospective cohort patient study, radiation dose was compared after adjusting for patient water equivalent diameter. Difference in subjective and objective image quality was assessed on a subset of 50 patients scanned on both scanners by two readers. RESULTS CTDIvol and noise from SDCT were higher than conventional CT for all phantoms, with a relative difference of 7.8% (range 5.3-14%) for radiation dose and average difference of 9.0% (range 5.5-11%) for noise. 718 SDCT and 937 conventional CT patients were included in the patient study. CTDIvol for SDCT patients tends to be lower for smaller patients (- 2%, 95% confidence interval (- 5%, - 0.2%) for 200 mm water equivalent diameter) and higher for larger patients compared to conventional CT (8%, (6%, 11%) for 400 mm). No difference was seen for subjective image quality, SNR, CNR, or image noise between the two scanners, except for higher image noise in the portal vein and higher signal in the aorta on SDCT. CONCLUSION Radiation dose for abdominal CT performed on SDCT is similar to the dose on a conventional CT for average size patients, lower for smaller patients, and slightly higher for larger patients. Image quality is similar between the two scanners.
Collapse
Affiliation(s)
- Xinhui Duan
- Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA.
| | - Lakshmi Ananthakrishnan
- Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA
| | - Jeffrey B Guild
- Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA
| | - Yin Xi
- Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA
| | - Prabhakar Rajiah
- Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA
- Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN, 55905, USA
| |
Collapse
|
19
|
Rajiah P, Parakh A, Kay F, Baruah D, Kambadakone AR, Leng S. Update on Multienergy CT: Physics, Principles, and Applications. Radiographics 2020; 40:1284-1308. [DOI: 10.1148/rg.2020200038] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Prabhakar Rajiah
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| | - Anushri Parakh
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| | - Fernando Kay
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| | - Dhiraj Baruah
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| | - Avinash R. Kambadakone
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| | - Shuai Leng
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.R., S.L.); Department of Radiology, Massachusetts General Hospital, Boston, Mass (A.P., A.R.K.); Department of Radiology, UT Southwestern Medical Center, Dallas, Tex (F.K.); and Department of Radiology, Medical University of South Carolina, Charleston, SC (D.B.)
| |
Collapse
|
20
|
McCollough CH, Boedeker K, Cody D, Duan X, Flohr T, Halliburton SS, Hsieh J, Layman RR, Pelc NJ. Principles and applications of multienergy CT: Report of AAPM Task Group 291. Med Phys 2020; 47:e881-e912. [DOI: 10.1002/mp.14157] [Citation(s) in RCA: 57] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2019] [Revised: 02/11/2020] [Accepted: 03/10/2020] [Indexed: 12/14/2022] Open
Affiliation(s)
| | - Kirsten Boedeker
- Canon (formerly Toshiba) Medical Systems Corporation 1440 Warnall Ave Los Angeles CA 90024 USA
| | - Dianna Cody
- University of Texas, M.D. Anderson Cancer Center 7163 Spanish Grant Galveston TX 77554‐7756 USA
| | - Xinhui Duan
- Southwestern Medical Center University of Texas 5323 Harry Hines Blvd Dallas TX 75390‐9071 USA
| | - Thomas Flohr
- Siemens Healthcare GmbH Siemensstr. 3 Forchheim BY 91031 Germany
| | | | - Jiang Hsieh
- GE Healthcare Technologies 3000 N. Grandview Blvd. W-1190 Waukesha WI 53188 USA
| | - Rick R. Layman
- University of Texas, M.D. Anderson Cancer Center 7163 Spanish Grant Galveston TX 77554‐7756 USA
| | - Norbert J. Pelc
- Stanford University 443 Via Ortega, Room 203 Stanford CA 94305‐4125 USA
| |
Collapse
|
21
|
Diagnostic accuracy of dual-energy computed tomography (DECT) to differentiate uric acid from non-uric acid calculi: systematic review and meta-analysis. Eur Radiol 2020; 30:2791-2801. [DOI: 10.1007/s00330-019-06559-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2019] [Revised: 10/22/2019] [Accepted: 10/30/2019] [Indexed: 01/16/2023]
|
22
|
Abstract
OBJECTIVE. The objective of this study was to demonstrate the feasibility of dual-energy CT (DECT) for locoregional staging of breast cancer and differentiation of tumor histotypes. MATERIALS AND METHODS. From January 2016 to July 2017, a total of 31 patients (mean [± SD] age, 55.8 ± 14.8 years) with breast cancer diagnosed by needle biopsy who underwent preoperative contrast-enhanced DECT for staging purposes were selected from a retrospective review of institutional databases. Monochromatic images obtained at 40 and 70 keV were evaluated by two readers who determining the number of hypervascularized tumors present and the largest tumor diameter for each breast. The attenuation values and iodine concentration of tumors and normal breast tissue and the ratios of these findings in each tissue type were recorded. Cancers were classified as ductal carcinoma in situ, invasive ductal carcinoma, and invasive lobular carcinoma. The reference standard was the final pathologic finding after surgery. RESULTS. A total of 64 tumor lesions were found at histopathologic analysis versus 67 on DECT for 34 breasts (three bilateral cancers were included). Nonparametric statistics were used. The largest lesion diameter observed DECT was 33.2 ± 20.5 mm versus 31.8 ± 20.5 mm on pathologic analysis, and cancer distribution was correctly classified for 31 of 34 (91%) cases. ROC curves derived from lesion iodine concentration showed that the optimal thresholds for distinguishing infiltrating carcinomas (invasive lobular and ductal carcinomas) and from other lesions were 1.70 mg/mL (sensitivity, 94.9%; specificity, 93.0%; AUC value, 0.968). ROC curves derived from the ratio of the iodine concentration in lesions to that in normal breast parenchyma showed that 6.13 was the optimal threshold to distinguish invasive ductal carcinoma from other lesions (sensitivity, 87.0%; specificity, 81.1%; AUC value, 0.914). CONCLUSION. DECT is feasible and seems to be a reliable tool for locoregional staging of breast cancer.
Collapse
|
23
|
Third-generation dual-source dual-energy CT in pediatric congenital heart disease patients: state-of-the-art. Radiol Med 2019; 124:1238-1252. [PMID: 31630332 DOI: 10.1007/s11547-019-01097-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Accepted: 10/09/2019] [Indexed: 12/11/2022]
|
24
|
Alharthy A, D’Mello M, Alabsi H, Murray N, Metwally O, Elbanna KY, Mohammed MF, Khosa F. Vascular Imaging: Utilization of Dual-Energy Computed Tomography. CURRENT RADIOLOGY REPORTS 2019. [DOI: 10.1007/s40134-019-0337-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
25
|
Böning G, Feldhaus F, Adelt S, Kahn J, Fehrenbach U, Streitparth F. Clinical routine use of virtual monochromatic datasets based on spectral CT in patients with hypervascularized abdominal tumors - evaluation of effectiveness and efficiency. Acta Radiol 2019; 60:425-432. [PMID: 29950111 DOI: 10.1177/0284185118786077] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
BACKGROUND Virtual monochromatic images (VMI) generated using spectral computed tomography (CT) are promising recently available tools to improve diagnostic performance in oncologic patients. PURPOSE To investigate if virtual monochromatic datasets are suitable for clinical routine use in patients with hypervascularized abdominal tumors. MATERIAL AND METHODS A total of 41 patients with hypervascularized hepatocellular carcinoma (HCC), renal cell carcinoma (RCC), or neuroendocrine tumors (NET) were enrolled in the study; 451 CT series were analyzed. In an intra-individual study design, virtual monochromatic datasets of the arterial phase of each scan were computed. Image quality was assessed objectively by determining signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR) and subjectively by using five-point Likert-scales. The volume CT dose index (CTDIvol) was taken from each radiation dose report. The increase in reading time was estimated from the increase in the number of images. RESULTS Intra-individual comparison of the spectral mode in the arterial phase with the portal venous phase revealed no significant increase in the applied dose. SNR, CNRtumor-to-liver , and CNRtumor-to-muscle were significantly increased by lowering virtual monochromatic energy. Subjective image quality scores revealed an increase of contrast in low energy datasets, resulting in significantly higher diagnostic confidence, but an increased image noise at low energies. While diagnostic confidence improved, taking all datasets into account resulted in a significantly longer estimated reading time. CONCLUSION In clinical practice, the use of low energy VMI improved diagnostic confidence without a significant increase in dose. The main disadvantage is a decrease in efficiency due to longer reading times.
Collapse
Affiliation(s)
- Georg Böning
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Felix Feldhaus
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Sebastian Adelt
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Johannes Kahn
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Uli Fehrenbach
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Florian Streitparth
- Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
26
|
Kayano S, Takano H, Takane Y, Satomura A, Ono K, Shimura H, Onodera S, Sato K. [Relationship between Quantitativeness of Iodine and Accuracy of Virtual Non-contrast Image in Dual-energy Computed Tomography]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2019; 75:247-253. [PMID: 30890672 DOI: 10.6009/jjrt.2019_jsrt_75.3.247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Dual-energy computed tomography (DE-CT) is the promising technology, such as enabling material decomposition, generation of the virtual monochromatic image, and measurement of effective atomic numbers. There are reports that utilization of the virtual non-contrast (VNC) image, the iodine map image, and the virtual monochromatic image can contribute to the improvement of lesion detection and its characterization, compared with conventional contrast CT by single-energy computed tomography (SE-CT). In addition, acquisition of the VNC images makes it possible to skip scanning of true non-contrast CT, which is also expected to reduce exposure. However, a reliable evaluation of the accuracy of the VNC image has not been established, and only a few reports have verified their accuracy. In this study, we evaluated the relationship between the quantitativeness of iodine and the CT value of VNC image. As a result of our study, when the iodine volume was overestimated, the CT value of the VNC image was lower than the reference value, and when the iodine volume was underestimated, the CT value was upper than the reference value. Moreover, we clarified that the CT value of the VNC image greatly diverges as the iodine volume increases.
Collapse
Affiliation(s)
- Shingo Kayano
- Department of Radiological Technology, Tohoku University Hospital
| | - Hirokazu Takano
- Department of Radiological Technology, Tohoku University Hospital
| | - Yumi Takane
- Department of Radiological Technology, Tohoku University Hospital
| | - Ayaka Satomura
- Department of Radiological Technology, Tohoku University Hospital
| | - Katsunori Ono
- Department of Radiological Technology, Tohoku University Hospital
| | - Hirotaka Shimura
- Department of Radiological Technology, Tohoku University Hospital
| | - Shu Onodera
- Department of Radiological Technology, Tohoku University Hospital
| | - Kazuhiro Sato
- Health Sciences, Tohoku University Graduate School of Medicine
| |
Collapse
|
27
|
De Santis D, Eid M, De Cecco CN, Jacobs BE, Albrecht MH, Varga-Szemes A, Tesche C, Caruso D, Laghi A, Schoepf UJ. Dual-Energy Computed Tomography in Cardiothoracic Vascular Imaging. Radiol Clin North Am 2018; 56:521-534. [PMID: 29936945 DOI: 10.1016/j.rcl.2018.03.010] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Dual energy computed tomography is becoming increasingly widespread in clinical practice. It can expand on the traditional density-based data achievable with single energy computed tomography by adding novel applications to help reach a more accurate diagnosis. The implementation of this technology in cardiothoracic vascular imaging allows for improved image contrast, metal artifact reduction, generation of virtual unenhanced images, virtual calcium subtraction techniques, cardiac and pulmonary perfusion evaluation, and plaque characterization. The improved diagnostic performance afforded by dual energy computed tomography is not associated with an increased radiation dose. This review provides an overview of dual energy computed tomography cardiothoracic vascular applications.
Collapse
Affiliation(s)
- Domenico De Santis
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, USA; Department of Radiological Sciences, Oncology and Pathology, University of Rome "Sapienza", Piazzale Aldo Moro 5, Rome 00185, Italy
| | - Marwen Eid
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, USA
| | - Carlo N De Cecco
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, USA
| | - Brian E Jacobs
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, USA
| | - Moritz H Albrecht
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, USA; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, Frankfurt am Main 60590, Germany
| | - Akos Varga-Szemes
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, USA
| | - Christian Tesche
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, USA; Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Lazarettstraße 36, Munich 80636, Germany
| | - Damiano Caruso
- Department of Radiological Sciences, Oncology and Pathology, University of Rome "Sapienza", Piazzale Aldo Moro 5, Rome 00185, Italy
| | - Andrea Laghi
- Department of Radiological Sciences, Oncology and Pathology, University of Rome "Sapienza", Piazzale Aldo Moro 5, Rome 00185, Italy
| | - Uwe Joseph Schoepf
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425, USA.
| |
Collapse
|
28
|
Mohammed MF, Elbanna KY, Mohammed AME, Murray N, Azzumea F, Almazied G, Nicolaou S. Practical Applications of Dual-Energy Computed Tomography in the Acute Abdomen. Radiol Clin North Am 2018; 56:549-563. [PMID: 29936947 DOI: 10.1016/j.rcl.2018.03.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
With new developments in workflow automation, as well as technological advances enabling faster imaging with improved image quality and dose profile, dual-energy computed tomography is being used more often in the imaging of the acutely ill and injured patient. Its ability to identify iodine, differentiate it from hematoma or calcification, and improve contrast resolution has proven invaluable in the assessment of organ perfusion, organ injury, and inflammation.
Collapse
Affiliation(s)
- Mohammed F Mohammed
- Medical Imaging Department, Abdominal Imaging Section, Ministry of the National Guard, Health Affairs, King Saud bin Abdulaziz University for Health Sciences, King Abdullah International Medical Research Center, Prince Mutib Ibn Abdullah Ibn Abdulaziz Road, Ar Rimayah, Riyadh 14611, Saudi Arabia.
| | - Khaled Y Elbanna
- Department of Medical Imaging, Emergency and Trauma Radiology Division, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5, Canada
| | - Abdelazim M E Mohammed
- Medical Imaging Department, Abdominal Imaging Section, Ministry of the National Guard, Health Affairs, King Saud bin Abdulaziz University for Health Sciences, King Abdullah International Medical Research Center, Prince Mutib Ibn Abdullah Ibn Abdulaziz Road, Ar Rimayah, Riyadh 14611, Saudi Arabia
| | - Nicolas Murray
- Department of Radiology, Vancouver General Hospital, 899 West 12th Avenue, Vancouver, British Columbia V5Z1M9, Canada
| | - Fahad Azzumea
- Medical Imaging Department, Abdominal Imaging Section, Ministry of the National Guard, Health Affairs, King Saud bin Abdulaziz University for Health Sciences, King Abdullah International Medical Research Center, Prince Mutib Ibn Abdullah Ibn Abdulaziz Road, Ar Rimayah, Riyadh 14611, Saudi Arabia
| | - Ghassan Almazied
- Medical Imaging Department, Abdominal Imaging Section, Ministry of the National Guard, Health Affairs, King Saud bin Abdulaziz University for Health Sciences, King Abdullah International Medical Research Center, Prince Mutib Ibn Abdullah Ibn Abdulaziz Road, Ar Rimayah, Riyadh 14611, Saudi Arabia
| | - Savvas Nicolaou
- Department of Radiology, Vancouver General Hospital, 899 West 12th Avenue, Vancouver, British Columbia V5Z1M9, Canada
| |
Collapse
|
29
|
Morgan DE. The Role of Dual-Energy Computed Tomography in Assessment of Abdominal Oncology and Beyond. Radiol Clin North Am 2018; 56:565-585. [PMID: 29936948 DOI: 10.1016/j.rcl.2018.03.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
The added value and strength of dual energy computed tomography for the evaluation of oncologic patients revolve around the use of lower energy reconstructed images and iodine material density images. Lower keV simulated monoenergetic images optimize soft tissue tumor to nontumoral attenuation differences and increase contrast to noise ratios to improve lesion detection. Iodine material density images or maps are helpful from a qualitative standpoint for image interpretation because they result in improved detection and characterization of tumors and lymph node involvement, and from a quantitative assessment by enabling interrogation of specific properties of tissues to predict and assess therapeutic response.
Collapse
Affiliation(s)
- Desiree E Morgan
- Department of Radiology University of Alabama at Birmingham, 619 19th Street South, JTN 456, Birmingham, AL 35249-6830, USA.
| |
Collapse
|
30
|
Single-source dual-energy computed tomography for the assessment of bone marrow oedema in vertebral compression fractures: a prospective diagnostic accuracy study. Eur Radiol 2018; 29:31-39. [DOI: 10.1007/s00330-018-5568-y] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2018] [Revised: 05/16/2018] [Accepted: 05/28/2018] [Indexed: 12/20/2022]
|
31
|
Albrecht MH, De Cecco CN, Schoepf UJ, Spandorfer A, Eid M, De Santis D, Varga-Szemes A, van Assen M, von Knebel-Doeberitz PL, Tesche C, Puntmann VO, Nagel E, Vogl TJ, Nance JW. Dual-energy CT of the heart current and future status. Eur J Radiol 2018; 105:110-118. [PMID: 30017266 DOI: 10.1016/j.ejrad.2018.05.028] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Revised: 05/17/2018] [Accepted: 05/29/2018] [Indexed: 11/19/2022]
Abstract
Several applications utilizing dual-energy cardiac CT (DECT) have recently transitioned from the realm of research into clinical workflows. DECT acquisition techniques and subsequent post-processing can provide improved qualitative analysis, allow quantitative imaging, and have the potential to decrease requisite radiation and contrast material doses. Additionally, several experimental DECT techniques are pending further investigation and may improve the diagnostic accuracy of cardiac CT and/or provide evaluation of emerging imaging biomarkers in the future. This review article will summarize the major applications utilizing DECT in diagnosis of cardiovascular disease, including both the clinically used and investigational techniques examined to date.
Collapse
Affiliation(s)
- Moritz H Albrecht
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States; University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt, Germany.
| | - Carlo N De Cecco
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States.
| | - U Joseph Schoepf
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States.
| | - Adam Spandorfer
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States.
| | - Marwen Eid
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States.
| | - Domenico De Santis
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States; University of Rome "Sapienza", Department of Radiological Sciences, Oncological and Pathological Sciences, Latina, Italy.
| | - Akos Varga-Szemes
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States.
| | - Marly van Assen
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States; University Medical Center Groningen, Center for Medical Imaging, Department of Radiology, Groningen, The Netherlands.
| | - Philipp L von Knebel-Doeberitz
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States.
| | - Christian Tesche
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States; Heart Center Munich-Bogenhausen, Department of Cardiology and Intensive Care Medicine, Munich, Germany.
| | - Valentina O Puntmann
- University Hospital Frankfurt, Institute of Experimental and Translational Cardiovascular Imaging, DZHK Centre for Cardiovascular Imaging, Frankfurt, Germany.
| | - Eike Nagel
- University Hospital Frankfurt, Institute of Experimental and Translational Cardiovascular Imaging, DZHK Centre for Cardiovascular Imaging, Frankfurt, Germany.
| | - Thomas J Vogl
- University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt, Germany.
| | - John W Nance
- Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, United States.
| |
Collapse
|
32
|
Tao SM, Li X, Schoepf UJ, Nance JW, Jacobs BE, Zhou CS, Gu HF, Lu MJ, Lu GM, Zhang LJ. Comparison of the effect of radiation exposure from dual-energy CT versus single-energy CT on double-strand breaks at CT pulmonary angiography. Eur J Radiol 2018; 101:92-96. [PMID: 29571808 DOI: 10.1016/j.ejrad.2018.02.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Revised: 11/19/2017] [Accepted: 02/03/2018] [Indexed: 11/19/2022]
Abstract
PURPOSE To compare the effect of dual-source dual-energy CT versus single-energy CT on DNA double-strand breaks (DSBs) in blood lymphocytes at CT pulmonary angiography (CTPA). METHODS AND MATERIALS Sixty-two patients underwent either dual-energy CTPA (Group 1: n = 21, 80/Sn140 kVp, 89/38 mAs; Group 2: n = 20, 100/Sn140 kVp, 89/76 mAs) or single-energy CTPA (Group 3: n = 21, 120 kVp, 110 mAs). Blood samples were obtained before and 5 min after CTPA. DSBs were assessed with fluorescence microscopy and Kruskal-Walls tests were used to compare DSBs levels among groups. Volume CT dose index (CTDIvol), dose length product (DLP) and organ radiation dose were compared using ANOVA. RESULTS There were increased excess DSB foci per lymphocyte 5 min after CTPA examinations in three groups (Group 1: P = .001; Group 2: P = .001; Group 3: P = .006). There were no differences among groups regarding excess DSB foci/cell and percentage of excess DSBs (Group 1, 23%; Group 2, 24%; Group 3, 20%; P = .932). CTDIvol, DLP and organ radiation dose in Group 1 were the lowest among the groups (all P < .001). CONCLUSION DSB is increased following dual-source and single-source CTPA, while dual-source dual-energy CT protocols do not increase the estimated radiation dose and also do not result in a higher incidence of DNA DSBs in patients undergoing CTPA.
Collapse
Affiliation(s)
- Shu Min Tao
- Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China
| | - Xie Li
- Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China
| | - U Joseph Schoepf
- Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Ashley River Tower, MSC 226, 25 Courtenay Dr. Charleston, SC 29401, United States
| | - John W Nance
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Ashley River Tower, MSC 226, 25 Courtenay Dr. Charleston, SC 29401, United States
| | - Brian E Jacobs
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Ashley River Tower, MSC 226, 25 Courtenay Dr. Charleston, SC 29401, United States
| | - Chang Sheng Zhou
- Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China
| | - Hai Feng Gu
- Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China
| | - Meng Jie Lu
- Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China
| | - Guang Ming Lu
- Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China
| | - Long Jiang Zhang
- Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China.
| |
Collapse
|
33
|
Almutairi A, Al Safran Z, AlZaabi SA, Sun Z. Dual energy CT angiography in peripheral arterial stents: optimal scanning protocols with regard to image quality and radiation dose. Quant Imaging Med Surg 2017; 7:520-531. [PMID: 29184764 DOI: 10.21037/qims.2017.10.07] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Background To determine the optimal scanning protocols of dual energy computed tomography angiography (DECTA) in terms of radiation dose and image quality assessment at different keV levels, and compare it with conventional computed tomography angiography (CTA) in patients treated with peripheral arterial stents. Methods Twenty-nine patients with previous stent placement in peripheral arteries were evaluated with DECTA. Images were reconstructed with virtual monochromatic spectral imaging (VMS) at 65, 68, 70 and 72 keV and adaptive statistical iterative reconstruction (ASIR) at 50% compared with CTA. Image quality comprising image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed, and radiation dose was compared. Effects of different type of peripheral arterial stents on image quality were also evaluated. Fifty-six uniquely identified stents that were located in common iliac arteries (CIA), external iliac arteries (EIA) and superficial femoral arteries (SFA) were evaluated. Results Within subjects, the results showed that DECTA images (VMS) had less noise than the CTA images for CIA, EIA and SFA stents, with the lowest noise at 72 keV. Also, the VMS images had greater SNR than the CTA images for the EIA stents (P<0.05); and the VMS images had greater CNR than the CTA images for CIA, EIA, and SFA stents (P<0.001). Also, on CT attenuation, VMS continued to outperform CTA, but to a lesser extent. Between subjects, average VMS noise varied significantly with the type of the stent used (P=0.025) for CIA stents. Radiation dose was highly significant between DECTA and conventional CTA scans (6.98 vs. 7.40 mSv, P=0.047). Conclusions We conclude that an optimal scanning protocol consisting of 72 keV and 50% ASIR leads to better image quality for DECTA in peripheral arterial stenting when compared to conventional CTA.
Collapse
Affiliation(s)
- Abdulrahman Almutairi
- Department of Medical Radiation Sciences, Curtin University, Perth, Western Australia, Australia.,Department of Medical Imaging, King Fahad Specialist Hospital, Dammam, Saudi Arabia
| | - Zakariya Al Safran
- Department of Medical Imaging, King Fahad Specialist Hospital, Dammam, Saudi Arabia
| | - Saif A AlZaabi
- Department of Medical Imaging, King Fahad Specialist Hospital, Dammam, Saudi Arabia
| | - Zhonghua Sun
- Department of Medical Radiation Sciences, Curtin University, Perth, Western Australia, Australia
| |
Collapse
|
34
|
Cardiac Dual-Energy CT Applications and Clinical Impact. CURRENT RADIOLOGY REPORTS 2017. [DOI: 10.1007/s40134-017-0237-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
35
|
Spampinato MV, Abid A, Matheus MG. Current Radiographic Iodinated Contrast Agents. Magn Reson Imaging Clin N Am 2017; 25:697-704. [PMID: 28964459 DOI: 10.1016/j.mric.2017.06.003] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Millions of radiologic examinations requiring the use of iodinated contrast are performed yearly in North America. Triiodobenzoic acid, the contrast agent molecule currently in use, is a benzene ring covalently bonded to the 3 iodine atoms. Iodinated contrast media can be divided in 4 categories: ionic monomers, ionic dimers, nonionic monomer, and nonionic dimers. Currently, second- and third-generation nonionic low-osmolar and iso-osmolar contrast media are used in clinical practice. The search for a safer and more effective iodinated contrast agents remains an ongoing challenge and important research topic.
Collapse
Affiliation(s)
- Maria Vittoria Spampinato
- Department of Radiology and Radiological Science, Medical University of South Carolina, 96 Jonathan Lucas Street MSC 323, Charleston, SC 29425, USA.
| | - Ahad Abid
- School of Medicine, University of South Carolina, 6311 Garners Ferry Road, Columbia, SC 29209, USA
| | - Maria Gisele Matheus
- Department of Radiology and Radiological Science, Medical University of South Carolina, 96 Jonathan Lucas Street MSC 323, Charleston, SC 29425, USA
| |
Collapse
|
36
|
|
37
|
|
38
|
|