• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4604544)   Today's Articles (35)   Subscriber (49371)
For: Martens B, Hendriks BMF, Mihl C, Wildberger JE. Tailoring Contrast Media Protocols to Varying Tube Voltages in Vascular and Parenchymal CT Imaging: The 10-to-10 Rule. Invest Radiol 2020;55:673-6. [PMID: 32898358 DOI: 10.1097/RLI.0000000000000682] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Number Cited by Other Article(s)
1
McDermott MC, Sartoretti T, Stammen L, Martens B, Jost G, Pietsch H, Gutjahr R, Schmidt B, Flohr TG, Alkadhi H, Wildberger JE. Countering Calcium Blooming With Personalized Contrast Media Injection Protocols: The 1-2-3 Rule for Photon-Counting Detector CCTA. Invest Radiol 2024:00004424-990000000-00217. [PMID: 38742928 DOI: 10.1097/rli.0000000000001078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
2
Nyman U, Leander P, Liss P, Sterner G, Brismar T. Absolute and relative GFR and contrast medium dose/GFR ratio: cornerstones when predicting the risk of acute kidney injury. Eur Radiol 2024;34:612-621. [PMID: 37540321 PMCID: PMC10791854 DOI: 10.1007/s00330-023-09962-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 05/19/2023] [Accepted: 05/24/2023] [Indexed: 08/05/2023]
3
Hagen F, Estler A, Hofmann J, Walder L, Faby S, Almarie B, Nikolaou K, Wrazidlo R, Horger M. Reduced versus standard dose contrast volume for contrast-enhanced abdominal CT in overweight and obese patients using photon counting detector technology vs. second-generation dual-source energy integrating detector CT. Eur J Radiol 2023;169:111153. [PMID: 38250749 DOI: 10.1016/j.ejrad.2023.111153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 10/11/2023] [Accepted: 10/16/2023] [Indexed: 01/23/2024]
4
Daniel S, Kopp M, Vollbrecht T, Zeilinger M, Fitz T, Muttke A, Feuerlein U, Uder M, May MS. Personalization of thoracoabdominal CT examinations using scanner integrated clinical decision support systems - Impact on the acquisition technique, scan range, and reconstruction type. Eur J Radiol 2023;167:111078. [PMID: 37688917 DOI: 10.1016/j.ejrad.2023.111078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2023] [Revised: 08/10/2023] [Accepted: 08/30/2023] [Indexed: 09/11/2023]
5
Wildberger JE, Alkadhi H. New Horizons in Vascular Imaging With Photon-Counting Detector CT. Invest Radiol 2023;58:499-504. [PMID: 36735383 DOI: 10.1097/rli.0000000000000957] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
6
Individualized Contrast Media Application Based on Body Weight and Contrast Enhancement in Computed Tomography of Livers without Steatosis. Diagnostics (Basel) 2022;12:diagnostics12071551. [PMID: 35885457 PMCID: PMC9322492 DOI: 10.3390/diagnostics12071551] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2022] [Revised: 06/23/2022] [Accepted: 06/23/2022] [Indexed: 11/16/2022]  Open
7
Martens B, Wildberger JE, Van Kuijk SMJ, De Vos-Geelen J, Jeukens CRLPN, Mihl C. Influence of Contrast Material Temperature on Patient Comfort and Image Quality in Computed Tomography of the Abdomen: A Randomized Controlled Trial. Invest Radiol 2022;57:85-89. [PMID: 34280944 DOI: 10.1097/rli.0000000000000807] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
8
Individualized Scan Protocols in Abdominal Computed Tomography: Radiation Versus Contrast Media Dose Optimization. Invest Radiol 2021;57:353-358. [PMID: 34935651 DOI: 10.1097/rli.0000000000000844] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
9
Low kV Computed Tomography of Parenchymal Abdominal Organs-A Systematic Animal Study of Different Contrast Media Injection Protocols. Tomography 2021;7:815-828. [PMID: 34941641 PMCID: PMC8705800 DOI: 10.3390/tomography7040069] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 11/17/2021] [Accepted: 11/23/2021] [Indexed: 01/14/2023]  Open
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA