1
|
McDermott MC, Sartoretti T, Stammen L, Martens B, Jost G, Pietsch H, Gutjahr R, Schmidt B, Flohr TG, Alkadhi H, Wildberger JE. Countering Calcium Blooming With Personalized Contrast Media Injection Protocols: The 1-2-3 Rule for Photon-Counting Detector CCTA. Invest Radiol 2024:00004424-990000000-00217. [PMID: 38742928 DOI: 10.1097/rli.0000000000001078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
OBJECTIVE Photon-counting detector computed tomography (PCD-CT) enables spectral data acquisition of CT angiographies allowing for reconstruction of virtual monoenergetic images (VMIs) in routine practice. Specifically, it has potential to reduce the blooming artifacts associated with densely calcified plaques. However, calcium blooming and iodine attenuation are inversely affected by energy level (keV) of the VMIs, creating a challenge for contrast media (CM) injection protocol optimization. A pragmatic and simple rule for calcium-dependent CM injection protocols is investigated and proposed for VMI-based coronary CT angiography with PCD-CT. MATERIALS AND METHODS A physiological circulation phantom with coronary vessels including calcified lesions (maximum CT value >700 HU) with a 50% diameter stenosis was injected into at iodine delivery rates (IDRs) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g I/s. Images were acquired using a first-generation dual-source PCD-CT and reconstructed at various VMI levels (between 45 and 190 keV). Iodine attenuation in the coronaries was measured at each IDR for each keV, and blooming artifacts from the calcified lesions were assessed including stenosis grading error (as % overestimation vs true lumen). The IDR to achieve 300 HU at each VMI level was then calculated and compared with stenosis grading accuracy to establish a general rule for CM injection protocols. RESULTS Plaque blooming artifacts and intraluminal iodine attenuation decreased with increasing keV. Fixed windowing (representing absolute worst case) resulted in stenosis overestimation from 77% ± 4% at 45 keV to 5% ± 2% at 190 keV, whereas optimized windowing resulted in overestimation from 29% ± 3% at 45 keV to 4% ± 1% at 190 keV. The required IDR to achieve 300 HU showed a strong linear correlation to VMI energy (R2 = 0.98). Comparison of this linear plot versus stenosis grading error and blooming artifact demonstrated that multipliers of 1, 2, and 3 times the reference IDR for theoretical clinical regimes of no, moderate, and severe calcification density, respectively, can be proposed as a general rule. CONCLUSIONS This study provides a proof-of-concept in an anthropomorphic phantom for a simple pragmatic adaptation of CM injection protocols in coronary CT angiography with PCD-CT. The 1-2-3 rule demonstrates the potential for reducing the effects of calcium blooming artifacts on overall image quality.
Collapse
Affiliation(s)
- Michael C McDermott
- From the Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, the Netherlands (M.C.M., T.S., L.S., B.M., T.G.F., J.E.W.); Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (T.S., H.A.); Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, the Netherlands (M.C.M., T.S., L.S., B.M., J.E.W.); Bayer AG, Berlin, Germany (M.C.M., G.J., H.P.); and Computed Tomography Division, Siemens Healthineers AG, Forchheim, Germany (R.G., B.S., T.G.F.)
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
2
|
Nyman U, Leander P, Liss P, Sterner G, Brismar T. Absolute and relative GFR and contrast medium dose/GFR ratio: cornerstones when predicting the risk of acute kidney injury. Eur Radiol 2024; 34:612-621. [PMID: 37540321 PMCID: PMC10791854 DOI: 10.1007/s00330-023-09962-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 05/19/2023] [Accepted: 05/24/2023] [Indexed: 08/05/2023]
Abstract
Glomerular filtration rate (GFR) is considered the best overall index of kidney function in health and disease and its use is recommended to evaluate the risk of iodine contrast medium-induced acute kidney injury (CI-AKI) either as a single parameter or as a ratio between the total contrast medium dose (gram iodine) and GFR. GFR may be expressed in absolute terms (mL/min) or adjusted/indexed to body surface area, relative GFR (mL/min/1.73 m2). Absolute and relative GFR have been used interchangeably to evaluate the risk of CI-AKI, which may be confusing and a potential source of errors. Relative GFR should be used to assess the GFR category of renal function as a sign of the degree of kidney damage and sensitivity for CI-AKI. Absolute GFR represents the excretion capacity of the individual and may be used to calculate the gram-iodine/absolute GFR ratio, an index of systemic drug exposure (amount of contrast medium in the body) that relates to toxicity. It has been found to be an independent predictor of AKI following percutaneous coronary angiography and interventions but has not yet been fully validated for computed tomography (CT). Prospective studies are warranted to evaluate the optimal gram-iodine/absolute GFR ratio to predict AKI at various stages of renal function at CT. Only GFR estimation (eGFR) equations based on standardized creatinine and/or cystatin C assays should be used. eGFRcystatin C/eGFRcreatinine ratio < 0.6 indicating selective glomerular hypofiltration syndrome may have a stronger predictive power for postcontrast AKI than creatinine-based eGFR. CLINICAL RELEVANCE STATEMENT: Once the degree of kidney damage is established by estimating relative GFR (mL/min/1.73 m2), contrast dose in relation to renal excretion capacity [gram-iodine/absolute GFR (mL/min)] may be the best index to evaluate the risk of contrast-induced kidney injury. KEY POINTS: • Relative glomerular filtration rate (GFR; mL/min/1.73 m2) should be used to assess the GFR category as a sign of the degree of kidney damage and sensitivity to contrast medium-induced acute kidney injury (CI-AKI). • Absolute GFR (mL/min) is the individual's actual excretion capacity and the contrast-dose/absolute GFR ratio is a measure of systemic exposure (amount of contrast medium in the body), relates to toxicity and should be expressed in gram-iodine/absolute GFR (mL/min). • Prospective studies are warranted to evaluate the optimal contrast medium dose/GFR ratio predicting the risk of CI-AKI at CT and intra-arterial examinations.
Collapse
Affiliation(s)
- Ulf Nyman
- Department of Translational Medicine, Division of Medical Radiology, University of Lund, Malmö, Sweden.
| | - Peter Leander
- Department of Translational Medicine, Division of Medical Radiology, University of Lund, Malmö, Sweden
| | - Per Liss
- Department of Surgical Sciences, Section of Radiology, Uppsala University, Uppsala, Sweden
| | - Gunnar Sterner
- Department of Nephrology, Skåne University Hospital, Malmö, Sweden
| | - Torkel Brismar
- Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institute/Karolinska University Hospital, Stockholm, Sweden
- Department of Radiology, Karolinska University Hospital in Huddinge, Stockholm, Sweden
| |
Collapse
|
3
|
Hagen F, Estler A, Hofmann J, Walder L, Faby S, Almarie B, Nikolaou K, Wrazidlo R, Horger M. Reduced versus standard dose contrast volume for contrast-enhanced abdominal CT in overweight and obese patients using photon counting detector technology vs. second-generation dual-source energy integrating detector CT. Eur J Radiol 2023; 169:111153. [PMID: 38250749 DOI: 10.1016/j.ejrad.2023.111153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 10/11/2023] [Accepted: 10/16/2023] [Indexed: 01/23/2024]
Abstract
PURPOSE To compare image quality of contrast-enhanced abdominal-CT using 1st-generation Dual Source Photon-Counting Detector CT (DS-PCD-CT) versus 2nd-generation Dual-Source Energy Integrating-Detector CT (DS-EID-CT) in patients with BMI ≥ 25, applying two different contrast agent volumes, vendor proposed protocols and different virtual monoenergetic images (VMI). METHOD 68 overweight (BMI ≥ 25 kgm2) patients (median age: 65 years; median BMI 33.3 kgm2) who underwent clinically indicated, portal-venous contrast-enhanced abdominal-CT on a commercially available 1st-generation DS-PCD-CT were prospectively included if they already have had a pre-exam on 2nd-generation DS-EID-CT using a standardized exam protocol. Obesity were defined by BMI-calculation (overweight: 25-29.9, obesity grade I: 30-34.9; obesity grade II: 35-39.9; obesity grade III: > 40) and by the absolute weight value. Body weight adapted contrast volume (targeted volume of 1.2 mL/kg for the 1st study and 0.8 mL/kg for the 2nd study) was applied in both groups. Dual Energy mode was used for both the DS-PCD-CT and the DS-EID-CT. Polychromatic images and VMI (40 keV and 70 keV) were reconstructed for both the DS-EID-CT and the DS-PCD-CT data (termed T3D). Two radiologists assessed subjective image quality using a 5-point Likert-scale. Each reader drew ROIs within parenchymatous organs and vascular structures to analyze image noise, contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). RESULTS Median time interval between scans was 12 months (Min: 6 months; Max: 36 months). BMI classification included overweight (n = 10, 14.7 %), obesity grade I (n = 38, 55.9 %), grade II (n = 13, 19.1 %) and grade III (n = 7, 10.3 %). The SNR achieved with DS-PCD-CT at QIR level 3was 12.61 vs. 11.47 (QIR 2) vs. 10.53 (DS-EID-CT), irrespective of parenchymatous organs. For vessels, the SNR were 16.73 vs. 14.20 (QIR 2) vs. 12.07 (DS-EID-CT). Moreover, the obtained median noise at QIR level 3 was as low as that of the DS-EID-CT (8.65 vs. 8.65). Both radiologists rated the image quality higher for DS-PCD-CT data sets (p < 0.05). The highest CNR was achieved at 40 keV for both scanners. T3D demonstrated significantly higher SNR and lower noise level compared to 40 keV and 70 keV. Median CTDIvol and DLP values for DS-PCD-CT and DS-EID-CT were 10.90 mGy (IQR: 9.31 - 12.50 mGy) vs. 16.55 mGy (IQR: 15.45 - 18.17 mGy) and 589.50 mGy * cm (IQR: 498.50 - 708.25 mGy * cm) vs. 848.75 mGy * cm (IQR: 753.43 - 969.58 mGy * cm) (p < 0.001). CONCLUSION Image quality can be maintained while significantly reducing the contrast volume and the radiation dose (27% and 34% lower DLP and 31% lower CDTIvol) for abdominal contrast-enhanced CT using a 1st-generation DS-PCD-CT. Moreover, polychromatic reconstruction T3D on a DS-PCD-CT enables sufficient diagnostic image quality for oncological imaging.
Collapse
Affiliation(s)
- Florian Hagen
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen, Germany
| | - Arne Estler
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen, Germany
| | - Johannes Hofmann
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen, Germany
| | - Lukas Walder
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen, Germany
| | | | - Bassel Almarie
- Neuromodulation Center and Center for Clinical Research Learning, Spaulding Rehabilitation Hospital, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen, Germany
| | - Robin Wrazidlo
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen, Germany
| | - Marius Horger
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen, Germany.
| |
Collapse
|
4
|
Daniel S, Kopp M, Vollbrecht T, Zeilinger M, Fitz T, Muttke A, Feuerlein U, Uder M, May MS. Personalization of thoracoabdominal CT examinations using scanner integrated clinical decision support systems - Impact on the acquisition technique, scan range, and reconstruction type. Eur J Radiol 2023; 167:111078. [PMID: 37688917 DOI: 10.1016/j.ejrad.2023.111078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2023] [Revised: 08/10/2023] [Accepted: 08/30/2023] [Indexed: 09/11/2023]
Abstract
OBJECTIVES This study evaluates the impact of a scanner-integrated, customized clinical decision support system (CDSS) on the acquisition technique, scan range, and reconstruction in thoracoabdominal CT. MATERIALS AND METHODS We applied CDSS in contrast-enhanced examinations of the trunk with various clinical indications on a recent scanner with the capability of dual-energy CT (DECT), anatomic landmark detection (ALD), and iterative metal-artifact reduction (MAR). Simple and comprehensive questions about the patient's breath hold capability, the anatomical region of interest, and metal implants can be answered after the localizer. The acquisition technique (single energy, SECT, or dual energy), scan range (chest-abdomen-pelvis or chest-abdomen), and reconstruction technique (with or without MAR) were then automatically adapted in the examination protocols in coherence with these selections. Retrospectively, we compared the usage rates for these techniques in 624 examinations on the study scanner with 740 examinations on a comparable scanner without CDSS. Subgroup analysis of effective dose (ED), scan duration, and image quality (IQ) was performed in the study group. RESULTS CDSS leads to an increased usage rate of DECT (64.4% vs. 2.8%) and MAR (75.4% vs. 44.0%). All scan range adaptations by ALD were successful. The resulting subjective IQ between single energy and DECT acquisitions was comparable (all p > 0.05). Scan duration was significantly longer in DECT than in SECT (16.9 s vs. 6.5 s; p < 0.001). However, the objective IQ was significantly higher in DECT (CNRD 2.1 vs. 1.8; p < 0.01), and the ED significantly lower (6.7 mSv vs. 7.6 mSv; p = 0.004). CONCLUSION CDSS for thoracoabdominal CT leads to a substantially increased usage rate of innovative techniques during acquisition and reconstruction. Patients with adapted protocols benefit from improved image quality and increased post-processing options at lower radiation doses.
Collapse
Affiliation(s)
- Sascha Daniel
- Departement of Radiology, University Hospital Erlangen, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, 91054, Erlangen, Germany.
| | - Markus Kopp
- Departement of Radiology, University Hospital Erlangen, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, 91054, Erlangen, Germany
| | - Thomas Vollbrecht
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany
| | - Martin Zeilinger
- Departement of Radiology, University Hospital Erlangen, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, 91054, Erlangen, Germany
| | - Tim Fitz
- Departement of Radiology, University Hospital Erlangen, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, 91054, Erlangen, Germany
| | | | | | - Michael Uder
- Departement of Radiology, University Hospital Erlangen, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, 91054, Erlangen, Germany; Imaging Science Institute, University Hospital Erlangen, Erlangen, Germany
| | - Matthias S May
- Departement of Radiology, University Hospital Erlangen, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, 91054, Erlangen, Germany; Imaging Science Institute, University Hospital Erlangen, Erlangen, Germany
| |
Collapse
|
5
|
Abstract
ABSTRACT Noninvasive vascular imaging with computed tomography (CT) has become the clinical mainstay for many indications and body regions. The recent introduction of photon-counting detector (PCD)-CT into clinical routine has further broadened the spectrum of vascular applications. Technical improvements of PCD-CT, such as the decreased noise levels, improved contrast-to-noise ratio, and full spectral multienergy data information from every acquisition, have the potential to further impact on clinical decision making and ultimately on outcome of vascular patients. Early experience with the new PCD-CT technology demonstrates these improvements in various aspects. This review summarizes the main advantages of PCD-CT for vascular imaging a discussion of the PureLumen and PureCalcium algorithms.
Collapse
Affiliation(s)
| | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
6
|
Individualized Contrast Media Application Based on Body Weight and Contrast Enhancement in Computed Tomography of Livers without Steatosis. Diagnostics (Basel) 2022; 12:diagnostics12071551. [PMID: 35885457 PMCID: PMC9322492 DOI: 10.3390/diagnostics12071551] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2022] [Revised: 06/23/2022] [Accepted: 06/23/2022] [Indexed: 11/16/2022] Open
Abstract
This study analyzes the homogeneity in liver attenuation of a body-weight-based protocol compared to a semi-fixed protocol. Patients undergoing abdominal multiphase computed tomography received 0.500 g of iodine (gI) per kilogram of body weight. Liver attenuation and enhancement were determined using regions of interest on scans in the pre-contrast and portal venous phases. The outcomes were analyzed for interpatient uniformity in weight groups. The subjective image quality was scored using a four-point Likert scale (excellent, good, moderate, and nondiagnostic). A total of 80 patients were included (56.3% male, 64 years, 78.0 kg) and were compared to 80 propensity-score-matched patients (62.5% male, 63 years, 81.7 kg). The liver attenuation values for different weight groups of the TBW-based protocol were not significantly different (p = 0.331): 109.1 ± 13.8 HU (≤70 kg), 104.6 ± 9.70 HU (70−90 kg), and 105.1 ± 11.6 HU (≥90 kg). For the semi-fixed protocol, there was a significant difference between the weight groups (p < 0.001): 121.1 ± 12.1 HU (≤70 kg), 108.9 ± 11.0 HU (70−90 kg), and 105.0 ± 9.8 HU (≥90 kg). For the TBW-based protocol, the enhancement was not significantly different between the weight groups (p = 0.064): 46.2 ± 15.1 HU (≤70 kg), 59.3 ± 6.8 HU (70−90 kg), and 52.1 ± 11.7 HU (≥90 kg). Additionally, for the semi-fixed protocol, the enhancement was not significantly different between the weight groups (p = 0.069): 59.4 ± 11.0 HU (≤70 kg), 53.0 ± 10.3 HU (70−90 kg), and 52.4 ± 7.5 HU (≥90 kg). The mean administered amount of iodine per kilogram was less for the TBW-based protocol compared to the semi-fixed protocol: 0.499 ± 0.012 and 0.528 ± 0.079, respectively (p = 0.002). Of the TBW-based protocol, 17.5% of the scans scored excellent enhancement quality, 76.3% good, and 6.3% moderate. Of the semi-fixed protocol, 70.0% scored excellent quality, 21.3% scored good, and 8.8% scored moderate. In conclusion, the TBW-based protocol increased the interpatient uniformity of liver attenuation but not the enhancement in the portal venous phase compared to the semi-fixed protocol, using an overall lower amount of contrast media and maintaining good subjective image quality.
Collapse
|
7
|
Martens B, Wildberger JE, Van Kuijk SMJ, De Vos-Geelen J, Jeukens CRLPN, Mihl C. Influence of Contrast Material Temperature on Patient Comfort and Image Quality in Computed Tomography of the Abdomen: A Randomized Controlled Trial. Invest Radiol 2022; 57:85-89. [PMID: 34280944 DOI: 10.1097/rli.0000000000000807] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND International guideline recommendations on safe use of contrast media (CM) are conflicting regarding the necessity to prewarm iodinated CM. PURPOSE Aim of the study was to evaluate the effects of room temperature CM compared with prewarmed CM on image quality, safety, and patient comfort in abdominal computed tomography (CT). METHODS CATCHY (Contrast Media Temperature and Patient Comfort in Computed Tomography of the Abdomen) is a double-blinded, randomized noninferiority trial. Between February and August 2020, 218 participants referred for portal venous abdominal CT were prospectively and randomly assigned to 1 of 2 groups. All patients received iopromide at 300 mg I/mL: group 1 at room temperature (~23°C [~73°F]) and group 2 prewarmed to body temperature (37°C [99°F]). A state-of-the-art individualized CM injection protocol was used, based on body weight and adapted to tube voltage. Primary outcome was absolute difference in mean liver attenuation between groups, calculated with a 2-sided 95% confidence interval. The noninferiority margin was set at -10 HU. Secondary outcomes were objective (signal-to-noise ratio and contrast-to-noise ratio) and subjective image quality; CM extravasations and other adverse events; and participant comfort (5-point scale questionnaire) and pain (numeric rating scale). This trial is registered with ClinicalTrials.gov (NCT04249479). RESULTS The absolute difference in mean attenuation between groups was + 4.23 HU (95% confidence interval, +0.35 to +8.11; mean attenuation, 122.2 ± 13.1 HU in group 1, 118.0 ± 15.9 HU in group 2; P = 0.03). Signal-to-noise ratio, contrast-to-noise ratio, and subjective image quality were not significantly different between groups (P = 0.53, 0.23, and 0.99 respectively). Contrast extravasation occurred in 1 patient (group 2), and no other adverse events occurred. Comfort scores were significantly higher in group 1 than in group 2 (P = 0.03); pain did not significantly differ (perceived P > 0.99; intensity P = 0.20). CONCLUSIONS Not prewarming iodinated CM was found noninferior in abdominal CT imaging. Prewarming conferred no beneficial effect on image quality, safety, and comfort, and might therefore no longer be considered a prerequisite in state-of-the art injection protocols for parenchymal imaging.
Collapse
Affiliation(s)
| | | | - Sander M J Van Kuijk
- Department of Clinical Epidemiology and Medical Technology Assessment, Maastricht University Medical Center
| | | | - Cécile R L P N Jeukens
- From the Department of Radiology and Nuclear Medicine, Maastricht University Medical Center
| | | |
Collapse
|
8
|
Individualized Scan Protocols in Abdominal Computed Tomography: Radiation Versus Contrast Media Dose Optimization. Invest Radiol 2021; 57:353-358. [PMID: 34935651 DOI: 10.1097/rli.0000000000000844] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND In contrast-enhanced abdominal computed tomography (CT), radiation and contrast media (CM) injection protocols are closely linked to each other, and therefore a combination is the basis for achieving optimal image quality. However, most studies focus on optimizing one or the other parameter separately. PURPOSE Reducing radiation dose may be most important for a young patient or a population in need of repetitive scanning, whereas CM reduction might be key in a population with insufficient renal function. The recently introduced technical solution, in the form of an automated tube voltage selection (ATVS) slider, might be helpful in this respect. The aim of the current study was to systematically evaluate feasibility of optimizing either radiation or CM dose in abdominal imaging compared with a combined approach. METHODS Six Göttingen minipigs (mean weight, 38.9 ± 4.8 kg) were scanned on a third-generation dual-source CT. Automated tube voltage selection and automated tube current modulation techniques were used, with quality reference values of 120 kVref and 210 mAsref. Automated tube voltage selection was set at 90 kV semimode. Three different abdominal scan and CM protocols were compared intraindividually: (1) the standard "combined" protocol, with the ATVS slider position set at 7 and a body weight-adapted CM injection protocol of 350 mg I/kg body weight, iodine delivery rate (IDR) of 1.1 g I/s; (2) the CM dose-saving protocol, with the ATVS slider set at 3 and CM dose lowered to 294 mg I/kg, resulting in a lower IDR of 0.9 g I/s; (3) the radiation dose-saving protocol, with the ATVS slider position set at 11 and a CM dose of 441 mg I/kg and an IDR 1.3 g I/s, respectively. Scans were performed with each protocol in arterial, portal venous, and delayed phase. Objective image quality was evaluated by measuring the attenuation in Hounsfield units, signal-to-noise ratio, and contrast-to-noise ratio of the liver parenchyma. The overall image quality, contrast quality, noise, and lesion detection capability were rated on a 5-point Likert scale (1 = excellent, 5 = very poor). Protocols were compared for objective image quality parameters using 1-way analysis of variance and for subjective image quality parameters using Friedman test. RESULTS The mean radiation doses were 5.2 ± 1.7 mGy for the standard protocol, 7.1 ± 2.0 mGy for the CM dose-saving protocol, and 3.8 ± 0.4 mGy for the radiation dose-saving protocol. The mean total iodine load in these groups was 13.7 ± 1.7, 11.4 ± 1.4, and 17.2 ± 2.1 g, respectively. No significant differences in subjective overall image or contrast quality were found. Signal-to-noise ratio and contrast-to-noise ratio were not significantly different between protocols in any scan phase. Significantly more noise was seen when using the radiation dose-saving protocol (P < 0.01). In portal venous and delayed phases, the mean attenuation of the liver parenchyma significantly differed between protocols (P < 0.001). Lesion detection was significantly better in portal venous phase using the CM dose-saving protocol compared with the radiation dose-saving protocol (P = 0.037). CONCLUSIONS In this experimental setup, optimizing either radiation (-26%) or CM dose (-16%) is feasible in abdominal CT imaging. Individualizing either radiation or CM dose leads to comparable objective and subjective image quality. Personalized abdominal CT examination protocols can thus be tailored to individual risk assessment and might offer additional degrees of freedom.
Collapse
|
9
|
Low kV Computed Tomography of Parenchymal Abdominal Organs-A Systematic Animal Study of Different Contrast Media Injection Protocols. Tomography 2021; 7:815-828. [PMID: 34941641 PMCID: PMC8705800 DOI: 10.3390/tomography7040069] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 11/17/2021] [Accepted: 11/23/2021] [Indexed: 01/14/2023] Open
Abstract
Objectives: To evaluate multiphase low kV computed tomography (CT) imaging of the abdomen with reduced contrast media (CM) dose using different injection protocols. Methods: Two injection protocols were evaluated for use with low kV (80 kV) multiphase abdominal imaging in comparison to the standard procedure acquired at 120 kV (500 mgI/kg; 5 mL/s). This evaluation was conducted in a highly standardized animal study (5 Goettingen minipigs). The low kV protocols consisted of (a) a single-flow (SF) injection with 40% reduced CM dose and injection rate (300 mgI/kg; 3 mL/s) and (b) a DualFlow (DF) injection protocol consisting of 60%/40% contrast to saline ratio administered at 5 mL/s. Dynamic CT was first performed within representative liver regions to determine optimal contrast phases, followed by evaluation of the three protocols in multiphase abdominal CT imaging. The evaluation criteria included contrast enhancement (CE) of abdominal organs and vasculature. Results: The 80 kV DF injection protocol showed similar CE of the abdominal parenchymatous organs and vessels to the 120 kV reference and the 80 kV SF protocol. Hepatic parenchyma showed comparable CT values for all contrast phases. In particular, in the portal venous parenchymal phase, the 80 kV DF protocol demonstrated higher hepatic parenchymal enhancement; however, results were statistically non-significant. Similarly, CE of the kidney, pancreas, and abdominal arterial/venous vessels showed no significant differences between injection protocols. Conclusions: Adapted SF and DF injection protocols with reduced IDR/iodine load offer the potential to calibrate optimal CM doses to the tube voltage in abdominal multiphase low kV CT imaging. The data suggest that the DF approach allows the use of predefined injection protocols and adaption of the contrast to saline ratio to an individualized kV setting and yields the potential for patient-individualized CM adaption.
Collapse
|