1
|
Virarkar MK, Vulasala SSR, Gupta AV, Gopireddy D, Kumar S, Hernandez M, Lall C, Bhosale P. Virtual Non-contrast Imaging in The Abdomen and The Pelvis: An Overview. Semin Ultrasound CT MR 2022; 43:293-310. [PMID: 35738815 DOI: 10.1053/j.sult.2022.03.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Virtual non-contrast (VNC) imaging is a post-processing technique generated from contrast-enhanced scans using dual-energy computed tomography (DECT). It is generated by removing iodine from imaging acquired at multiple energies. Myriad clinical studies have shown its ability to diagnose the various abdominal and pelvic pathologies discussed in the article. VNC is also a problem-solving tool for characterizing incidentally detected lesions ("incidentalomas"), often decreasing the need for additional follow-up imaging. It also obviates the multiphase image acquisitions to evaluate hematuria, hepatic steatosis, aortic endoleaks, and gastrointestinal bleeding by generating image datasets from different tissue attenuation values. The scope of this article is to provide an overview of various applications of VNC imaging obtained by DECT in the abdomen and pelvis.
Collapse
Affiliation(s)
- Mayur K Virarkar
- Department of Radiology, University of Florida College of Medicine, Jacksonville, FL
| | | | | | | | - Sindhu Kumar
- Department of Radiology, University of Florida College of Medicine, Jacksonville, FL
| | - Mauricio Hernandez
- Department of Radiology, University of Florida College of Medicine, Jacksonville, FL
| | - Chandana Lall
- Department of Radiology, University of Florida College of Medicine, Jacksonville, FL
| | - Priya Bhosale
- Department of Diagnostic Radiology, Division of Diagnostic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX
| |
Collapse
|
2
|
Hepatobiliary Dual-Energy Computed Tomography. Radiol Clin North Am 2022; 60:731-743. [DOI: 10.1016/j.rcl.2022.05.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
3
|
Do TD, Melzig C, Vollherbst DF, Pereira PL, Kauczor HU, Kachelrieß M, Sommer CM. The value of iterative metal artifact reduction algorithms during antenna positioning for CT-guided microwave ablation. Int J Hyperthermia 2019; 36:1223-1232. [PMID: 31814464 DOI: 10.1080/02656736.2019.1690168] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023] Open
Abstract
Objectives: To compare image quality between filtered back projection (FBP) and iterative reconstruction algorithm and dedicated metal artifact reduction (iMAR) algorithms during antenna positioning for computed tomography-guided microwave ablation (MWA).Materials and methods: An MWA antenna was positioned in the liver of five pigs under CT guidance. Different exposure settings (120kVp/200mAs-120kVp/50mAs) and image reconstruction techniques (FBP, iterative reconstruction with and without iMAR) were applied. Quantitative image analysis included density measurements in six positions (e.g., liver in extension of the antenna [ANTENNA] and liver >3 cm away from the antenna [LIVER-1]). Qualitative image analysis included assessment of overall quality, image noise, artifacts at the antenna tip, artifacts in liver parenchyma bordering antenna tip and newly generated artifacts. Two independent observers performed the analyses twice and interreader agreement was compared with Bland-Altman analysis.Results: For all exposure and reconstruction settings, density measurements for ANTENNA were significantly higher for the I30-1 iMAR compared with FBP and I30-1 (e.g., 8.3-17.2HU vs. -104.5 to 155.1HU; p ≤ 0.01, respectively). In contrast, for all exposure settings, density measurements for LIVER-1 were comparable between FBP and I30-1 iMAR (e.g., 49.4-50.4HU vs. 50.1-52.5U, respectively). For all exposure and reconstruction settings, subjective image quality for LIVER-1 was better for the I30-1 iMAR algorithm compared with FBP and I30-1. Bland-Altman interobserver agreement was from -0.2 to 0.2 for FBP and iMAR, and Cohen's kappa was 0.74.Conclusion: Iterative algorithms I30-1 with iMAR algorithm improves image quality during antenna positioning and placement for CT-guided MWA and is applicable over a range of exposure settings.
Collapse
Affiliation(s)
- Thuy Duong Do
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Claudius Melzig
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Dominik F Vollherbst
- Department of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Philippe L Pereira
- Clinic for Radiology, Minimally-Invasive Therapies and Nuclear Medicine, SLK Kliniken Heilbronn GmbH, Heilbronn, Germany
| | - Hans-Ulrich Kauczor
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Marc Kachelrieß
- Medical Physics in Radiology, German Cancer Research Center (Dkfz), Heidelberg, Germany
| | - Christof M Sommer
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany.,Clinic for Diagnostic and Interventional Radiology, Klinikum Stuttgart, Stuttgart, Germany
| |
Collapse
|
4
|
Skornitzke S, Fritz F, Mayer P, Koell M, Hansen J, Pahn G, Hackert T, Kauczor HU, Stiller W. Dual-energy CT iodine maps as an alternative quantitative imaging biomarker to abdominal CT perfusion: determination of appropriate trigger delays for acquisition using bolus tracking. Br J Radiol 2018; 91:20170351. [PMID: 29446319 DOI: 10.1259/bjr.20170351] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
OBJECTIVE Quantitative evaluation of different bolus tracking trigger delays for acquisition of dual energy (DE) CT iodine maps as an alternative to CT perfusion. METHODS Prior to this retrospective analysis of prospectively acquired data, DECT perfusion sequences were dynamically acquired in 22 patients with pancreatic carcinoma using dual source CT at 80/140 kVp with tin filtration. After deformable motion-correction, perfusion maps of blood flow (BF) were calculated from 80 kVp image series of DECT, and iodine maps were calculated for each of the 34 DECT acquisitions per patient. BF and iodine concentrations were measured in healthy pancreatic tissue and carcinoma. To evaluate potential DECT acquisition triggered by bolus tracking, measured iodine concentrations from the 34 DECT acquisitions per patient corresponding to different trigger delays were assessed for correlation to BF and intergroup differences between tissue types depending on acquisition time. RESULTS Average BF measured in healthy pancreatic tissue and carcinoma was 87.6 ± 28.4 and 38.6 ± 22.2 ml/100 ml min-1, respectively. Correlation between iodine concentrations and BF was statistically significant for bolus tracking with trigger delay greater than 0 s (rmax = 0.89; p < 0.05). Differences in iodine concentrations between healthy pancreatic tissue and carcinoma were statistically significant for DECT acquisitions corresponding to trigger delays of 15-21 s (p < 0.05). CONCLUSION An acquisition window between 15 and 21 s after exceeding bolus tracking threshold shows promising results for acquisition of DECT iodine maps as an alternative to CT perfusion measurements of BF. Advances in knowledge: After clinical validation, DECT iodine maps of pancreas acquired using bolus tracking with appropriate trigger delay as determined in this study could offer an alternative quantitative imaging biomarker providing functional information for tumor assessment at reduced patient radiation exposure compared to CT perfusion measurements of BF.
Collapse
Affiliation(s)
- Stephan Skornitzke
- 1 Diagnostic and Interventional Radiology (DIR), University Hospital Heidelberg , Heidelberg , Germany
| | - Franziska Fritz
- 1 Diagnostic and Interventional Radiology (DIR), University Hospital Heidelberg , Heidelberg , Germany
| | - Philipp Mayer
- 1 Diagnostic and Interventional Radiology (DIR), University Hospital Heidelberg , Heidelberg , Germany
| | - Marco Koell
- 1 Diagnostic and Interventional Radiology (DIR), University Hospital Heidelberg , Heidelberg , Germany
| | - Jens Hansen
- 1 Diagnostic and Interventional Radiology (DIR), University Hospital Heidelberg , Heidelberg , Germany
| | - Gregor Pahn
- 1 Diagnostic and Interventional Radiology (DIR), University Hospital Heidelberg , Heidelberg , Germany
| | - Thilo Hackert
- 2 General Visceral and Transplantation Surgery, University Hospital Heidelberg , Heidelberg , Germany
| | - Hans-Ulrich Kauczor
- 1 Diagnostic and Interventional Radiology (DIR), University Hospital Heidelberg , Heidelberg , Germany
| | - Wolfram Stiller
- 1 Diagnostic and Interventional Radiology (DIR), University Hospital Heidelberg , Heidelberg , Germany
| |
Collapse
|
5
|
Yamada Y, Yamada M, Sugisawa K, Akita H, Shiomi E, Abe T, Okuda S, Jinzaki M. Renal cyst pseudoenhancement: intraindividual comparison between virtual monochromatic spectral images and conventional polychromatic 120-kVp images obtained during the same CT examination and comparisons among images reconstructed using filtered back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction. Medicine (Baltimore) 2015; 94:e754. [PMID: 25881852 PMCID: PMC4602515 DOI: 10.1097/md.0000000000000754] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
The purpose of this study was to compare renal cyst pseudoenhancement between virtual monochromatic spectral (VMS) and conventional polychromatic 120-kVp images obtained during the same abdominal computed tomography (CT) examination and among images reconstructed using filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR). Our institutional review board approved this prospective study; each participant provided written informed consent. Thirty-one patients (19 men, 12 women; age range, 59-85 years; mean age, 73.2 ± 5.5 years) with renal cysts underwent unenhanced 120-kVp CT followed by sequential fast kVp-switching dual-energy (80/140 kVp) and 120-kVp abdominal enhanced CT in the nephrographic phase over a 10-cm scan length with a random acquisition order and 4.5-second intervals. Fifty-one renal cysts (maximal diameter, 18.0 ± 14.7 mm [range, 4-61 mm]) were identified. The CT attenuation values of the cysts as well as of the kidneys were measured on the unenhanced images, enhanced VMS images (at 70 keV) reconstructed using FBP and ASIR from dual-energy data, and enhanced 120-kVp images reconstructed using FBP, ASIR, and MBIR. The results were analyzed using the mixed-effects model and paired t test with Bonferroni correction. The attenuation increases (pseudoenhancement) of the renal cysts on the VMS images reconstructed using FBP/ASIR (least square mean, 5.0/6.0 Hounsfield units [HU]; 95% confidence interval, 2.6-7.4/3.6-8.4 HU) were significantly lower than those on the conventional 120-kVp images reconstructed using FBP/ASIR/MBIR (least square mean, 12.1/12.8/11.8 HU; 95% confidence interval, 9.8-14.5/10.4-15.1/9.4-14.2 HU) (all P < .001); on the other hand, the CT attenuation values of the kidneys on the VMS images were comparable to those on the 120-kVp images. Regardless of the reconstruction algorithm, 70-keV VMS images showed a lower degree of pseudoenhancement of renal cysts than 120-kVp images, while maintaining kidney contrast enhancement comparable to that on 120-kVp images.
Collapse
Affiliation(s)
- Yoshitake Yamada
- From the Department of Diagnostic Radiology (YY, KS, HA, ES, SO, MJ), Keio University School of Medicine; Multi-dimension Biomedical Imaging & Information Laboratory in Research Park (MY), Keio University School of Medicine; and Department of Preventive Medicine and Public Health, Center for Clinical Research, Keio University School of Medicine (TA), Shinjuku-ku, Tokyo, Japan
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Yamada Y, Jinzaki M, Hosokawa T, Tanami Y, Abe T, Kuribayashi S. Abdominal CT: an intra-individual comparison between virtual monochromatic spectral and polychromatic 120-kVp images obtained during the same examination. Eur J Radiol 2014; 83:1715-22. [PMID: 25015416 DOI: 10.1016/j.ejrad.2014.06.004] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2014] [Revised: 06/06/2014] [Accepted: 06/08/2014] [Indexed: 11/18/2022]
Abstract
OBJECTIVES To compare quantitative and subjective image quality between virtual monochromatic spectral (VMS) and conventional polychromatic 120-kVp imaging performed during the same abdominal computed tomography (CT) examination. MATERIALS AND METHODS Our institutional review board approved this prospective study; each participant provided written informed consent. 51 patients underwent sequential fast kVp-switching dual-energy (80/140 kVp, volume CT dose index: 12.7 mGy) and single-energy (120-kVp, 12.7 mGy) abdominal enhanced CT over an 8 cm scan length with a random acquisition order and a 4.3-s interval. VMS images with filtered back projection (VMS-FBP) and adaptive statistical iterative reconstruction (so-called hybrid IR) (VMS-ASIR) (at 70 keV), as well as 120-kVp images with FBP (120-kVp-FBP) and ASIR (120-kVp-ASIR), were generated from dual-energy and single-energy CT data, respectively. The objective image noises, signal-to-noise ratios and contrast-to-noise ratios of the liver, kidney, pancreas, spleen, portal vein and aorta, and the lesion-to-liver and lesion-to-kidney contrast-to-noise ratios were measured. Two radiologists independently and blindly assessed the subjective image quality. The results were analyzed using the paired t-test, Wilcoxon signed rank sum test and mixed-effects model with Bonferroni correction. RESULTS VMS-ASIR images were superior to 120-kVp-FBP, 120-kVp-ASIR and VMS-FBP images for all the quantitative assessments and the subjective overall image quality (all P<0.001), while VMS-FBP images were superior to 120-kVp-FBP and 120-kVp-ASIR images (all P<0.004). CONCLUSIONS VMS images at 70 keV have a higher image quality than 120-kVp images, regardless of the application of hybrid IR. Hybrid IR can further improve the image quality of VMS imaging.
Collapse
Affiliation(s)
- Yoshitake Yamada
- Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
| | - Masahiro Jinzaki
- Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
| | - Takahiro Hosokawa
- Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
| | - Yutaka Tanami
- Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
| | - Takayuki Abe
- Center for Clinical Research, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
| | - Sachio Kuribayashi
- Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
| |
Collapse
|
7
|
Del Gaizo AJ, Silva AC, Hara AK. The utility of dual-energy computed tomography in abdominal imaging. APPLIED RADIOLOGY 2014. [DOI: 10.37549/ar2048] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
8
|
Determinants of second-order bile duct visualization at CT cholangiography in potential living liver donors. AJR Am J Roentgenol 2013; 200:1028-33. [PMID: 23617485 DOI: 10.2214/ajr.11.8364] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
OBJECTIVE The purpose of this article is to investigate the determinants of second-order bile duct visualization at CT cholangiography in living potential liver donors. MATERIALS AND METHODS We retrospectively identified 143 potential living liver donors (83 men and 60 women; mean age, 37 years) evaluated with CT cholangiography, which included a slow infusion of iodipamide meglumine with CT acquisition 15 minutes after biliary contrast agent administration. Two readers independently scored the visualization of the second-order bile duct branches on a previously established 4-point scale (0 = not seen, 1 = faintly seen, 2 = well seen, and 3 = excellent visualization). Multivariate analysis was used to investigate the correlation between visualization scores and potential determinants of second-order bile duct opacification, specifically age, body mass index, creatinine level, total and direct bilirubin levels, alkaline phosphatase level, aspartate aminotransferase level, alanine aminotransferase level, patient maximum linear width, CT noise, and hepatosplenic attenuation difference at unenhanced CT. RESULTS The mean (± SD) second-order bile duct visualization scores were 2.35 ± 0.66 and 2.55 ± 0.60 for readers 1 and 2, respectively. In the multivariate analysis, the only independent predictors of reduced second-order bile duct visualization were higher alkaline phosphatase level (p = 0.01) and higher CT noise (p = 0.02). CONCLUSION Higher serum alkaline phosphatase level and higher CT noise in potential living liver donors indicate a higher risk of poor second-order bile duct visualization at CT cholangiography.
Collapse
|
9
|
Stampfl U, Sommer CM, Bellemann N, Holzschuh M, Kueller A, Bluemmel J, Gehrig T, Shevchenko M, Kenngott H, Kauczor HU, Radeleff B. Multimodal visibility of a modified polyzene-F-coated spherical embolic agent for liver embolization: feasibility study in a porcine model. J Vasc Interv Radiol 2012; 23:1225-31.e2. [PMID: 22832143 DOI: 10.1016/j.jvir.2012.06.008] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2012] [Revised: 05/27/2012] [Accepted: 06/05/2012] [Indexed: 12/11/2022] Open
Abstract
PURPOSE To evaluate multimodal visibility of modified currently available microspheres on radiography, magnetic resonance (MR) imaging, and computed tomography (CT) in a porcine liver model. MATERIALS AND METHODS Livers of four pigs were embolized with two sizes (100 μm ± 25 and 700 μm ± 50) of modified Embozene Microspheres embedded with different densities of barium sulfate and iodine as radiopaque materials (intensity groups A-C, with increasing intensity from A to C for 100 μm and intensities A and C for 700 μm) and iron oxide as magnetic substance for MR imaging visibility. Pigs embolized with currently available Embozene Microspheres served as control groups. Pre- and postinterventional MR imaging (T1- and T2-weighted) and CT were performed. Qualitative and quantitative (ie, determination of signal-to-noise ratio [SNR]) particle visibility was evaluated on radiography, MR imaging, and CT. RESULTS Modified particles of both sizes were visible on radiography, MR imaging, and CT. Particles in the control group were not visible. For modified particles of both sizes, SNRs measured on MR imaging decreased significantly after embolization (eg, cluster analysis of group A, 100 μm ± 50 particles, T1-weighted, -74.6% ± 3.4; P = .03). For modified particles of both sizes, SNR measured on CT increased significantly after embolization (eg, cluster analysis of group A, 700 μm ± 25 particles, +54.3% ± 13.5; P = .03). CONCLUSIONS Modification of currently available Embozene Microspheres was successful, with multimodal visibility on radiography, MR imaging, and CT in porcine liver. In the future, this might improve procedure accuracy and allow monitoring, control, and improvement of embolotherapy during and after the procedure.
Collapse
Affiliation(s)
- Ulrike Stampfl
- Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Cui Y, Gao SY, Wang ZL, Li XT, Sun YS, Tang L, Zhang XP. Which should be the routine cross-sectional reconstruction mode in spectral CT imaging: monochromatic or polychromatic? Br J Radiol 2012; 85:e887-90. [PMID: 22723512 DOI: 10.1259/bjr/27844842] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To provide evidence for the selection of an optimal cross-sectional reconstruction mode in spectral CT imaging of the abdomen, we compared the monochromatic images with polychromatic images. METHODS Three phase-enhanced CT scans of the abdomen were recorded using the spectral imaging technique on 100 patients. Images were reconstructed using two modes: polychromatic and 70 keV monochromatic. The following variables were then compared: contrast-to-noise ratio (CNR) of the liver, spleen, gallbladder, kidney and pancreas, and the noise. Paired t-tests were used to compare differences between the two sets of images. Three experienced doctors graded the quality of the images with a five-point scale. The image quality scores were compared with a non-parametric rank sum test. RESULTS Compared with polychromatic images, the 70 keV monochromatic mode images yielded significantly greater tissue-to-fat CNR and lower noise (p<0.001 for all comparisons). The image quality of the 70 keV monochromatic mode showed significantly better results than the polychromatic mode (p<0.001). CONCLUSIONS In abdominal spectral CT imaging, 70 keV monochromatic mode reconstruction images were better than those reconstructed using the polychromatic mode. The monochromatic mode may become the routine reconstruction mode for cross-sectional images.
Collapse
Affiliation(s)
- Y Cui
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education), Department of Radiology, Peking University School of Oncology, Beijing Cancer Hospital and Institute, Beijing, China
| | | | | | | | | | | | | |
Collapse
|
11
|
Iodine removal in intravenous dual-energy CT-cholangiography: Is virtual non-enhanced imaging effective to replace true non-enhanced imaging? Eur J Radiol 2012; 81:692-9. [DOI: 10.1016/j.ejrad.2011.01.087] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2010] [Accepted: 01/20/2011] [Indexed: 11/23/2022]
|
12
|
|
13
|
Sommer CM, Schwarzwaelder CB, Stiller W, Schindera ST, Heye T, Stampfl U, Bellemann N, Holzschuh M, Schmidt J, Weitz J, Grenacher L, Kauczor HU, Radeleff BA. Dual-energy CT-cholangiography in potential donors for living-related liver transplantation: improved biliary visualization by intravenous morphine co-medication. Eur J Radiol 2011; 81:2007-13. [PMID: 21696902 DOI: 10.1016/j.ejrad.2011.05.016] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2011] [Revised: 05/10/2011] [Accepted: 05/13/2011] [Indexed: 11/24/2022]
Abstract
PURPOSE To prospectively evaluate whether intravenous morphine co-medication improves bile duct visualization of dual-energy CT-cholangiography. MATERIALS AND METHODS Forty potential donors for living-related liver transplantation underwent CT-cholangiography with infusion of a hepatobiliary contrast agent over 40 min. Twenty minutes after the beginning of the contrast agent infusion, either normal saline (n=20 patients; control group [CG]) or morphine sulfate (n=20 patients; morphine group [MG]) was injected. Forty-five minutes after initiation of the contrast agent, a dual-energy CT acquisition of the liver was performed. Applying dual-energy post-processing, pure iodine images were generated. Primary study goals were determination of bile duct diameters and visualization scores (on a scale of 0 to 3: 0--not visualized; 3--excellent visualization). RESULTS Bile duct visualization scores for second-order and third-order branch ducts were significantly higher in the MG compared to the CG (2.9±0.1 versus 2.6±0.2 [P<0.001] and 2.7±0.3 versus 2.1±0.6 [P<0.01], respectively). Bile duct diameters for the common duct and main ducts were significantly higher in the MG compared to the CG (5.9±1.3 mm versus 4.9±1.3 mm [P<0.05] and 3.7±1.3 mm versus 2.6±0.5 mm [P<0.01], respectively). CONCLUSION Intravenous morphine co-medication significantly improved biliary visualization on dual-energy CT-cholangiography in potential donors for living-related liver transplantation.
Collapse
Affiliation(s)
- C M Sommer
- Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Stiller W, Schwarzwaelder CB, Sommer CM, Veloza S, Radeleff BA, Kauczor HU. Dual-energy, standard and low-kVp contrast-enhanced CT-cholangiography: a comparative analysis of image quality and radiation exposure. Eur J Radiol 2011; 81:1405-12. [PMID: 21458939 DOI: 10.1016/j.ejrad.2011.03.030] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2010] [Revised: 02/28/2011] [Accepted: 03/03/2011] [Indexed: 11/18/2022]
Abstract
OBJECTIVE Quantitative image quality assessment in terms of image noise (IN), contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) in relation to required radiation dose (RD) for dual-energy (DE), standard and low-kVp contrast-enhanced computed-tomography (CT) cholangiography. MATERIALS AND METHODS For each of 22 DECT-cholangiography examinations, 3 image datasets were analyzed as independent single-source CT-acquisitions at different tube potential, i.e. 80 kVp, 120 kVp-equivalent (linear blended dataset M0.3: 30% 80 kVp, 70% 140 kVp), and 140 kVp. Analysis comprised determination of IN, CNR and SNR in regions of interest (ROI) placed in liver parenchyma and contrasted bile ducts. IN was evaluated as mean standard deviation of 3 ROI placed within liver parenchyma (segments 6/7, 5/8, 2/3); CNR was assessed as bile duct-to-liver parenchyma ratio, and SNR as bile duct-to-image noise ratio. RD in terms of CT dose index (CTDI(vol)), dose-length product (DLP) and effective dose (ED) has been determined for each of the datasets, and compared to console prediction and scan summary values. Using phantom measurements of CTDI(vol), a method for separating comprehensive RD values of DE-acquisitions into the original RD contribution of each tube (80 kVp/140 kVp) has been developed, enabling comparison of all 3 datasets as if independently acquired using single-source "single-energy" technique. RESULTS Highest IN was detected for 80 kVp- (38.6 ± 5.1HU), lowest for 120 kVp-equivalent linear blended M0.3-datasets (23.1 ± 3.4HU) with significant differences between all datasets (P<0.001). Highest SNR and CNR were measured for M0.3- (SNR: 14.8 ± 4.1; CNR: 11.6 ± 3.8) and 80 kVp-datasets (SNR: 13.8 ± 4.8; CNR: 11.2 ± 4.5); lowest for 140 kVp-datasets (SNR: 9.5 ± 2.5; CNR: 7.1 ± 2.3) with significant differences between M0.3- and 140 kVp-datasets as well as between 80 kVp- and 140 kVp-datasets (both P<0.001 for both CNR, SNR). CTDI(vol), DLP and ED were reduced by 50% for low-kilovoltage acquisitions (CTDI(vol): 5.5 ± 1.4 mGy; DLP: 127.8 ± 40.1 mGy cm; ED: 1.9 ± 0.6 mSv) compared to comprehensive DE-acquisitions (CTDI(vol): 11.0 ± 2.3 mGy; DLP: 253.8 ± 67.5 mGy cm; ED: 3.8 ± 1.0 mSv, tube contribution: 80 kVp: 44.5%; 140 kVp: 55.5%), and by 20% compared to conventional acquisitions at 120 kVp (CTDI(vol): 6.71 mGy; DLP: 153.5 ± 16.9 mGy cm; ED: 2.3 ± 0.3 mSv). CONCLUSIONS Despite higher IN, low-kilovoltage CT-cholangiography reveals no significant difference with respect to CNR and SNR when compared to linear blended images yielded by DECT. Compared to DECT or conventional CT at 120 kVp, contrast-enhanced low-kVp CT cholangiography potentially allows reduction of patient dose by up to 50% or 20%, respectively. Therefore, CT-cholangiography at 80 kVp should be considered as an alternative to DECT-cholangiography whenever DECT is unavailable, or if increased image quality of DECT regarding quantitative bile duct evaluation is not needed for diagnosis.
Collapse
Affiliation(s)
- W Stiller
- Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg, Germany.
| | | | | | | | | | | |
Collapse
|