Tandem use of gastroesophageal resuscitative occlusion of the aorta followed by resuscitative endovascular balloon occlusion of the aorta in a lethal liver laceration model.
J Trauma Acute Care Surg 2023;
94:148-155. [PMID:
35687798 DOI:
10.1097/ta.0000000000003719]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND
Gastroesophageal resuscitative occlusion of the aorta (GROA) has been shown effective in creating zone II aortic occlusion capable of temporarily improving survival in animal models of lethal noncompressible torso hemorrhage. In this study, tandem application of GROA transitioning to resuscitative endovascular balloon occlusion of the aorta (REBOA) is explored to demonstrate feasibility as a potential point-of-injury bridge to more advanced care, using a swine model of lethal abdominal hemorrhage.
METHODS
Swine (n = 19) were anesthetized, instrumented, and subjected to a combination of controlled and uncontrolled hemorrhage from a grade-V liver laceration. Animals were designated as intervention (n = 9; GROA to REBOA) or control (n = 10), for 60 minutes. Following intervention, devices were deactivated, and animals received blood and crystalloid resuscitation. Animals were monitored for 4 hours.
RESULTS
Injury resulted in onset of class IV shock in all animals with a mean arterial pressure (SD) of 24.5 (4.11) mm Hg at the start of intervention. Nine of 10 controls died during the intervention period with a median (interquartile) survival time of 8.5 (9.25) minutes. All animals receiving the intervention survived both the 60-minute intervention period demonstrating a significant survival improvement ( p = 0.0007). Transition from GROA to REBOA was successful in all animals with a transition time ranging from 30 to 90 seconds. Mean arterial pressure significantly improved in animals receiving GROA to REBOA for the duration of intervention, regardless of the method of aortic occlusion, with a range of 70.9 (16.04) mm Hg to 101.1 (15.3) mm Hg. Additional hemodynamics, metrics of shock, and oxygenation remained stable during intervention.
CONCLUSION
Less invasive technologies such as GROA may present an opportunity to control noncompressible torso hemorrhage more rapidly, with a subsequent transition to more advanced care such as REBOA.
Collapse