1
|
Charlès LM, von Reiterdank IF, Lancia HH, Shamlou AA, Berkane Y, Rosales I, Mink van der Molen AB, Coert J, Cetrulo CL, Lellouch AG, Uygun K. Effect of Subnormothermic Machine Perfusion on the Preservation of Vascularized Composite Allografts After Prolonged Warm Ischemia. Transplantation 2024; 108:2222-2232. [PMID: 38722685 PMCID: PMC11518650 DOI: 10.1097/tp.0000000000005035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/25/2024]
Abstract
BACKGROUND Warm ischemia time (WIT) and ischemia-reperfusion injury are limiting factors for vascularized composite allograft (VCA) transplantation. Subnormothermic machine perfusion (SNMP) has demonstrated the potential to extend WIT in organ transplantation. This study evaluates the effect of SNMP on VCA viability after prolonged WIT. METHODS Rat hindlimbs underwent WIT for 30, 45, 60, 120, 150, or 210 min, followed by 3-h SNMP. Monitoring of perfusion parameters and outflow determined the maximum WIT compatible with limb viability after SNMP. Thereafter, 2 groups were assessed: a control group with inbred transplantation (Txp) after 120 min of WIT and an experimental group that underwent WIT + SNMP + Txp. Graft appearance, blood gas, cytokine levels, and histology were assessed for 21 d. RESULTS Based on potassium levels, the limit of WIT compatible with limb viability after SNMP is 120 min. Before this limit, SNMP reduces potassium and lactate levels of WIT grafts to the same level as fresh grafts. In vivo, the control group presented 80% graft necrosis, whereas the experimental group showed no necrosis, had better healing ( P = 0.0004), and reduced histological muscle injury ( P = 0.012). Results of blood analysis revealed lower lactate, potassium levels, and calcium levels ( P = 0.048) in the experimental group. Both groups presented an increase in interleukin (IL)-10 and IL-1b/IL-1F2 with a return to baseline after 7 to 14 d. CONCLUSIONS Our study establishes the limit of WIT compatible with VCA viability and demonstrates the effectiveness of SNMP in restoring a graft after WIT ex vivo and in vivo, locally and systemically.
Collapse
Affiliation(s)
- Laura M. Charlès
- Vascularized Composite Allotransplantation Laboratory, Massachusetts General Hospital, Boston, MA
- Harvard Medical School, Boston, MA
- Shriners Children’s Boston, Boston, MA, USA
| | - Irina Filz von Reiterdank
- Vascularized Composite Allotransplantation Laboratory, Massachusetts General Hospital, Boston, MA
- Harvard Medical School, Boston, MA
- Shriners Children’s Boston, Boston, MA, USA
- Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Boston, MA
- Department of Plastic, Reconstructive and Hand Surgery, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Hyshem H Lancia
- Vascularized Composite Allotransplantation Laboratory, Massachusetts General Hospital, Boston, MA
- Harvard Medical School, Boston, MA
- Shriners Children’s Boston, Boston, MA, USA
| | - Austin Alana Shamlou
- Vascularized Composite Allotransplantation Laboratory, Massachusetts General Hospital, Boston, MA
- Harvard Medical School, Boston, MA
- Shriners Children’s Boston, Boston, MA, USA
| | - Yanis Berkane
- Vascularized Composite Allotransplantation Laboratory, Massachusetts General Hospital, Boston, MA
- Harvard Medical School, Boston, MA
- Shriners Children’s Boston, Boston, MA, USA
- Department of Plastic, Reconstructive and Aesthetic Surgery, Rennes University Hospital Center (CHU de Rennes), Rennes University, Rennes, France
| | - Ivy Rosales
- Department of Pathology, Massachusetts General Hospital, Boston, MA
| | - Aebele B. Mink van der Molen
- Department of Plastic, Reconstructive and Hand Surgery, University Medical Center Utrecht, Utrecht, The Netherlands
| | - J.H Coert
- Department of Plastic, Reconstructive and Hand Surgery, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Curtis L Cetrulo
- Vascularized Composite Allotransplantation Laboratory, Massachusetts General Hospital, Boston, MA
- Harvard Medical School, Boston, MA
- Shriners Children’s Boston, Boston, MA, USA
| | - Alexandre G Lellouch
- Vascularized Composite Allotransplantation Laboratory, Massachusetts General Hospital, Boston, MA
- Harvard Medical School, Boston, MA
- Shriners Children’s Boston, Boston, MA, USA
| | - Korkut Uygun
- Harvard Medical School, Boston, MA
- Shriners Children’s Boston, Boston, MA, USA
- Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Boston, MA
| |
Collapse
|
2
|
Brouwers K, van Geel SRWM, van Midden D, Kruit AS, Kusters B, Hummelink S, Ulrich DJO. Added Value of Histological Evaluation of Muscle Biopsies in Porcine Vascularized Composite Allografts. J Clin Med 2024; 13:5167. [PMID: 39274379 PMCID: PMC11395792 DOI: 10.3390/jcm13175167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2024] [Revised: 07/31/2024] [Accepted: 08/27/2024] [Indexed: 09/16/2024] Open
Abstract
Background: Machine perfusion (MP) offers extended preservation of vascularized complex allografts (VCA), but the diagnostic value of histology using hematoxylin and eosin (H&E) in detecting ischemia-reperfusion injury (IRI) in muscle cells remains unclear. This study aims to document the application of the Histology Injury Severity Score (HISS) and to assess whether additional staining for nicotinamide adenine dinucleotide (NADH) and membrane attack complex (MAC) improves IRI detection in a porcine limb replantation model. Methods: The forelimbs of 16 Dutch Landrace pigs were amputated and preserved for 24 h using hypothermic MP (n = 8) with Histidine-Tryptophan-Ketoglutarate (HTK) or for 4 h with SCS (n = 8) before heterotopic replantation and 7 days of follow-up. Muscle damage was assessed via biochemical markers and light microscopy using H&E, NADH, and MAC at baseline, post-intervention, and post-operative day (POD) 1, 3, and 7 timepoints, using the HISS and a self-developed NADH and MAC score. Results: H&E effectively identified damaged muscle fibers and contributed to IRI assessment in porcine limbs (p < 0.05). The highest HISS was measured on POD 3 between MP (4.9) and SCS (3.5) (p = 0.029). NADH scores of both preservation groups varied over the 7-day follow-up and were statistically insignificant compared with baseline measurements (p > 0.05). MAC revealed no to minimal necrotic tissue across the different timepoints. Conclusions: This study documents the application of the HISS with H&E to detect IRI in muscle fibers. NADH and MAC showed no significant added diagnostic utility. The 24 h MP showed similar muscle alterations using the HISS compared to that of the 4 h SCS after a 7-day follow up.
Collapse
Affiliation(s)
- Kaj Brouwers
- Department of Plastic and Reconstructive Surgery, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands
| | - Shannen R W M van Geel
- Department of Plastic and Reconstructive Surgery, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands
| | - Dominique van Midden
- Department of Pathology, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands
| | - Anne Sophie Kruit
- Department of Plastic and Reconstructive Surgery, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands
| | - Benno Kusters
- Department of Pathology, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands
| | - Stefan Hummelink
- Department of Plastic and Reconstructive Surgery, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands
| | - Dietmar J O Ulrich
- Department of Plastic and Reconstructive Surgery, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands
| |
Collapse
|
3
|
Marlar R, Abbas F, Obeid R, Frisbie S, Ghazoul A, Rezaee A, Sims J, Rampazzo A, Bassiri Gharb B. A meta-analysis of perfusion parameters affecting weight gain in ex vivo perfusion. Artif Organs 2024. [PMID: 39157933 DOI: 10.1111/aor.14841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Revised: 07/08/2024] [Accepted: 07/27/2024] [Indexed: 08/20/2024]
Abstract
BACKGROUND Ex vivo machine perfusion (EVMP) has been established to extend viability of donor organs. However, EVMP protocols are inconsistent. We hypothesize that there is a significant relationship between specific parameters during EVMP and perfusion outcomes. METHODS A meta-analysis of literature was conducted in accordance with the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) Statement. The search encompassed articles published before July 25, 2023. PubMed, Embase, and CENTRAL databases were screened using search terms "ex-vivo," "ex-situ," "machine," and "perfusion." Weight gain, an indicator of organ viability, was chosen to compare outcomes. Extracted variables included perfused organ, warm and cold ischemia time before perfusion, perfusion duration, perfusate flow, pressure, temperature, perfusate composition (presence of cellular or acellular oxygen carrier, colloids, and other supplements) and percent weight change. Data were analyzed using SPSS statistical software. RESULTS Overall, 44 articles were included. Red blood cell-based perfusates resulted in significantly lower weight gain compared to acellular perfusates without oxygen carriers (11.3% vs. 27.0%, p < 0.001). Hemoglobin-based oxygen carriers resulted in significantly lower weight gain compared to acellular perfusates (16.5% vs. 27%, p = 0.006). Normothermic perfusion led to the least weight gain (14.6%), significantly different from hypothermic (24.3%) and subnormothermic (25.0%) conditions (p < 0.001), with no significant difference between hypothermic and subnormothermic groups (24.3% vs. 25.0%, p = 0.952). There was a positive correlation between flow rate and weight gain (ß = 13.1, R = 0.390, p < 0.001). CONCLUSIONS Oxygen carriers, low flow rates, and normothermic perfusate temperature appear to improve outcomes in EVMP. These findings offer opportunities for improving organ transplantation outcomes.
Collapse
Affiliation(s)
- Riley Marlar
- Department of Plastic Surgery, Cleveland Clinic, Cleveland, Ohio, USA
| | - Fuad Abbas
- Department of Plastic Surgery, Cleveland Clinic, Cleveland, Ohio, USA
| | - Rommy Obeid
- Department of Plastic Surgery, Cleveland Clinic, Cleveland, Ohio, USA
| | - Sean Frisbie
- Department of Plastic Surgery, Cleveland Clinic, Cleveland, Ohio, USA
| | - Adam Ghazoul
- Department of Plastic Surgery, Cleveland Clinic, Cleveland, Ohio, USA
| | - Ava Rezaee
- Department of Plastic Surgery, Cleveland Clinic, Cleveland, Ohio, USA
| | - Jack Sims
- Department of Plastic Surgery, Cleveland Clinic, Cleveland, Ohio, USA
| | - Antonio Rampazzo
- Department of Plastic Surgery, Cleveland Clinic, Cleveland, Ohio, USA
| | | |
Collapse
|
4
|
Ben Brahim B, Arenas Hoyos I, Zhang L, Vögelin E, Olariu R, Rieben R. Tacrolimus-loaded Drug Delivery Systems in Vascularized Composite Allotransplantation: Lessons and Opportunities for Local Immunosuppression. Transplantation 2024:00007890-990000000-00769. [PMID: 38773862 DOI: 10.1097/tp.0000000000005049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/24/2024]
Abstract
Long-term systemic immunosuppression is needed for vascularized composite allotransplantation (VCA). The high rate of acute rejection episodes in the first posttransplant year, the development of chronic rejection, and the adverse effects that come along with this treatment, currently prevent a wider clinical application of VCA. Opportunistic infections and metabolic disturbances are among the most observed side effects in VCA recipients. To overcome these challenges, local immunosuppression using biomaterial-based drug delivery systems (DDS) have been developed. The aim of these systems is to provide high local concentrations of immunosuppressive drugs while reducing their systemic load. This review provides a summary of recently investigated local DDS with different mechanisms of action such as on-demand, ultrasound-sensitive, or continuous drug delivery. In preclinical models, ranging from rodent to porcine and nonhuman primate models, this approach has been shown to reduce systemic tacrolimus (TAC) load and adverse effects, while prolonging graft survival. Localized immunosuppression using biomaterial-based DDS represents an encouraging approach to enhance graft survival and reduce toxic side effects of immunosuppressive drugs in VCA patients. Preclinical models using TAC-releasing DDS have demonstrated high local immunosuppressive effects with a low systemic burden. However, to reduce acute rejection events in translational animal models or in the clinical reality, the use of additional low-dose systemic TAC treatment may be envisaged. Patients may benefit through efficient graft immunosuppression and survival with negligible systemic adverse effects, resulting in better compliance and quality of life.
Collapse
Affiliation(s)
- Bilal Ben Brahim
- Department for BioMedical Research, University of Bern, Bern, Switzerland
| | - Isabel Arenas Hoyos
- Department for BioMedical Research, University of Bern, Bern, Switzerland
- Department of Plastic and Hand Surgery, Inselspital Bern University Hospital, Bern, Switzerland
| | - Lei Zhang
- Department for BioMedical Research, University of Bern, Bern, Switzerland
- Department of Plastic and Hand Surgery, Inselspital Bern University Hospital, Bern, Switzerland
| | - Esther Vögelin
- Department for BioMedical Research, University of Bern, Bern, Switzerland
- Department of Plastic and Hand Surgery, Inselspital Bern University Hospital, Bern, Switzerland
| | - Radu Olariu
- Department for BioMedical Research, University of Bern, Bern, Switzerland
- Department of Plastic and Hand Surgery, Inselspital Bern University Hospital, Bern, Switzerland
| | - Robert Rieben
- Department for BioMedical Research, University of Bern, Bern, Switzerland
| |
Collapse
|
5
|
López-Martínez S, Simón C, Santamaria X. Normothermic Machine Perfusion Systems: Where Do We Go From Here? Transplantation 2024; 108:22-44. [PMID: 37026713 DOI: 10.1097/tp.0000000000004573] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/08/2023]
Abstract
Normothermic machine perfusion (NMP) aims to preserve organs ex vivo by simulating physiological conditions such as body temperature. Recent advancements in NMP system design have prompted the development of clinically effective devices for liver, heart, lung, and kidney transplantation that preserve organs for several hours/up to 1 d. In preclinical studies, adjustments to circuit structure, perfusate composition, and automatic supervision have extended perfusion times up to 1 wk of preservation. Emerging NMP platforms for ex vivo preservation of the pancreas, intestine, uterus, ovary, and vascularized composite allografts represent exciting prospects. Thus, NMP may become a valuable tool in transplantation and provide significant advantages to biomedical research. This review recaps recent NMP research, including discussions of devices in clinical trials, innovative preclinical systems for extended preservation, and platforms developed for other organs. We will also discuss NMP strategies using a global approach while focusing on technical specifications and preservation times.
Collapse
Affiliation(s)
- Sara López-Martínez
- Carlos Simon Foundation, Centro de Investigación Príncipe Felipe, Valencia, Spain
| | - Carlos Simón
- Carlos Simon Foundation, Centro de Investigación Príncipe Felipe, Valencia, Spain
- Department of Obstetrics and Gynecology, Universidad de Valencia, Valencia, Spain
- Department of Obstetrics and Gynecology, Beth Israel Deaconess Medical Center, Harvard University, Boston, MA
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, TX
| | - Xavier Santamaria
- Carlos Simon Foundation, Centro de Investigación Príncipe Felipe, Valencia, Spain
- INCLIVA Biomedical Research Institute, Valencia, Spain
| |
Collapse
|
6
|
Duru Ç, Biniazan F, Hadzimustafic N, D'Elia A, Shamoun V, Haykal S. Review of machine perfusion studies in vascularized composite allotransplant preservation. FRONTIERS IN TRANSPLANTATION 2023; 2:1323387. [PMID: 38993931 PMCID: PMC11235328 DOI: 10.3389/frtra.2023.1323387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 12/04/2023] [Indexed: 07/13/2024]
Abstract
The applications of Vascularized composite allotransplantation (VCA) are increasing since the first successful hand transplantation in 1998. However, the abundance of muscle tissue makes VCA's vulnerable to ischemia-reperfusion injury (IRI), which has detrimental effects on the outcome of the procedure, restricting allowable donor-to-recipient time and limiting its widespread use. The current clinical method is Static cold storage (SCS) and this allows only 6 h before irreversible damage occurs upon reperfusion. In order to overcome this obstacle, the focus of research has been shifted towards the prospect of ex-vivo perfusion preservation which already has an established clinical role in solid organ transplants especially in the last decade. In this comprehensive qualitative review, we compile the literature on all VCA machine perfusion models and we aim to highlight the essentials of an ex vivo perfusion set-up, the different strategies, and their associated outcomes.
Collapse
Affiliation(s)
- Çağdaş Duru
- Latner Thoracic Surgery Laboratories, University Health Network (UHN), Toronto, ON, Canada
| | - Felor Biniazan
- Latner Thoracic Surgery Laboratories, University Health Network (UHN), Toronto, ON, Canada
| | - Nina Hadzimustafic
- Latner Thoracic Surgery Laboratories, University Health Network (UHN), Toronto, ON, Canada
- Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
| | - Andrew D'Elia
- Latner Thoracic Surgery Laboratories, University Health Network (UHN), Toronto, ON, Canada
- Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
| | - Valentina Shamoun
- Latner Thoracic Surgery Laboratories, University Health Network (UHN), Toronto, ON, Canada
| | - Siba Haykal
- Latner Thoracic Surgery Laboratories, University Health Network (UHN), Toronto, ON, Canada
- Plastic and Reconstructive Surgery, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
7
|
Muss TE, Loftin AH, Oh BC, Brandacher G. Current opinion: advances in machine perfusion and preservation of vascularized composite allografts - will time still matter? Curr Opin Organ Transplant 2023; 28:419-424. [PMID: 37823760 DOI: 10.1097/mot.0000000000001107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/13/2023]
Abstract
PURPOSE OF REVIEW A major hurdle hindering more widespread application of reconstructive transplantation is the very limited cold ischemia time (CIT) of vascularized composite allografts (VCAs). In this review, we discuss cutting edge machine perfusion protocols and preservation strategies to overcome this limitation. RECENT FINDINGS Several preclinical machine perfusion studies have demonstrated the multifactorial utility of this technology to extend preservation windows, assess graft viability prior to transplantation and salvage damaged tissue, yet there are currently no clinically approved machine perfusion protocols for reconstructive transplantation. Thus, machine perfusion remains an open challenge in VCA due to the complexity of the various tissue types. In addition, multiple other promising avenues to prolong preservation of composite allografts have emerged. These include cryopreservation, high subzero preservation, vitrification and nanowarming. Despite several studies demonstrating extended preservation windows, there are several limitations that must be overcome prior to clinical translation. As both machine perfusion and subzero preservation protocols have rapidly advanced in the past few years, special consideration should be given to their potential complementary utilization. SUMMARY Current and emerging machine perfusion and preservation technologies in VCA have great promise to transform the field of reconstructive transplantation, as every extra hour of CIT helps ease the complexities of the peri-transplant workflow. Amongst the many advantages, longer preservation windows may allow for elective procedures, improved matching, establishment of novel immunomodulatory protocols and global transport of grafts, ultimately enabling us the ability to offer this life changing procedure to more patients.
Collapse
Affiliation(s)
- Tessa E Muss
- Department of Plastic and Reconstructive Surgery, Vascularized Composite Allotransplantation (VCA) Laboratory
| | - Amanda H Loftin
- Department of Plastic and Reconstructive Surgery, Vascularized Composite Allotransplantation (VCA) Laboratory
- Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Byoung Chol Oh
- Department of Plastic and Reconstructive Surgery, Vascularized Composite Allotransplantation (VCA) Laboratory
| | - Gerald Brandacher
- Department of Plastic and Reconstructive Surgery, Vascularized Composite Allotransplantation (VCA) Laboratory
| |
Collapse
|
8
|
Bateman LM, Hebert KA, Nunziata JA, Streeter SS, Barth CW, Wang LG, Gibbs SL, Henderson ER. Preclinical evaluation of molecularly targeted fluorescent probes in perfused amputated human limbs. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:082802. [PMID: 36619496 PMCID: PMC9813435 DOI: 10.1117/1.jbo.28.8.082802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Accepted: 11/09/2022] [Indexed: 06/17/2023]
Abstract
SIGNIFICANCE This first-in-kind, perfused, and amputated human limb model allows for the collection of human data in preclinical selection of lead fluorescent agents. The model facilitates more accurate selection and testing of fluorophores with human-specific physiology, such as differential uptake and signal in fat between animal and human models with zero risk to human patients. Preclinical testing using this approach may also allow for the determination of tissue toxicity, clearance time of fluorophores, and the production of harmful metabolites. AIM This study was conducted to determine the fluorescence intensity values and tissue specificity of a preclinical, nerve tissue targeted fluorophore, as well as the capacity of this first-in-kind model to be used for lead fluorescent agent selection in the future. APPROACH Freshly amputated human limbs were perfused for 30 min prior to in situ and ex vivo imaging of nerves with both open-field and closed-field commercial fluorescence imaging systems. RESULTS In situ, open-field imaging demonstrated a signal-to-background ratio (SBR) of 4.7 when comparing the nerve with adjacent muscle tissue. Closed-field imaging demonstrated an SBR of 3.8 when the nerve was compared with adipose tissue and 4.8 when the nerve was compared with muscle. CONCLUSIONS This model demonstrates an opportunity for preclinical testing, evaluation, and selection of fluorophores for use in clinical trials as well as an opportunity to study peripheral pathologies in a controlled environment.
Collapse
Affiliation(s)
- Logan M. Bateman
- Dartmouth Health, Department of Orthopaedics, Lebanon, New Hampshire, United States
| | - Kendra A. Hebert
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | - Jenna A. Nunziata
- Dartmouth Health, Heart and Vascular Center, Lebanon, New Hampshire, United States
| | - Samuel S. Streeter
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | - Connor W. Barth
- Oregon Health and Science University, Department of Biomedical Engineering, Portland, Oregon, United States
| | - Lei G. Wang
- Oregon Health and Science University, Department of Biomedical Engineering, Portland, Oregon, United States
| | - Summer L. Gibbs
- Oregon Health and Science University, Department of Biomedical Engineering, Portland, Oregon, United States
| | - Eric R. Henderson
- Dartmouth Health, Department of Orthopaedics, Lebanon, New Hampshire, United States
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
- Dartmouth College, Geisel School of Medicine, Hanover, New Hampshire, United States
| |
Collapse
|
9
|
Bateman LM, Hebert KA, Streeter SS, Nunziata JA, Barth CW, Wang LG, Gibbs SL, Henderson ER. Use of Freshly Amputated Human Limbs for Pre-Clinical Evaluation of Molecular-Targeted Fluorescent Probes. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2023; 12361:1236109. [PMID: 37009433 PMCID: PMC10065840 DOI: 10.1117/12.2650356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/17/2023]
Abstract
We have co-developed a first-in-kind model of fluorophore testing in freshly amputated human limbs. Ex vivo human tissue provides a unique opportunity for the testing of pre-clinical fluorescent agents, collection of imaging data, and histopathologic examination in human tissue prior to performing in vivo experiments. Existing pre-clinical fluorescent agent studies rely primarily on animal models, which do not directly predict fluorophore performance in humans and can result in wasted resources and time if an agent proves ineffective in early human trials. Because fluorophores have no desired therapeutic effect, their clinical utility is based solely on their safety and ability to highlight tissues of interest. Advancing to human trials even via the FDA's phase 0/microdose pathway still requires substantial resources, single-species pharmacokinetic testing, and toxicity testing. In a recently concluded study using amputated human lower limbs, we were able to test successfully a nerve-specific fluorophore in pre-clinical development. This study used systemic administration via vascular cannulization and a cardiac perfusion pump. We envision that this model may assist with early lead agent testing selection for fluorophores with various targets and mechanisms.
Collapse
Affiliation(s)
- Logan M Bateman
- Department of Orthopaedics, Dartmouth Health, Lebanon, New Hampshire, United States
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, United States
| | - Kendra A Hebert
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, United States
| | - Samuel S Streeter
- Department of Orthopaedics, Dartmouth Health, Lebanon, New Hampshire, United States
- Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, United States
| | - Jenna A Nunziata
- Heart and Vascular Center, Dartmouth Health, Lebanon, New Hampshire, United States
| | - Connor W Barth
- Department of Biomedical Engineering, Oregon Health and Science University, Portland, Oregon, United States
| | - Lei G Wang
- Department of Biomedical Engineering, Oregon Health and Science University, Portland, Oregon, United States
| | - Summer L Gibbs
- Department of Biomedical Engineering, Oregon Health and Science University, Portland, Oregon, United States
| | - Eric R Henderson
- Department of Orthopaedics, Dartmouth Health, Lebanon, New Hampshire, United States
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, United States
- Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, United States
| |
Collapse
|
10
|
He J, Khan UZ, Qing L, Wu P, Tang J. Improving the ischemia-reperfusion injury in vascularized composite allotransplantation: Clinical experience and experimental implications. Front Immunol 2022; 13:998952. [PMID: 36189311 PMCID: PMC9523406 DOI: 10.3389/fimmu.2022.998952] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Accepted: 08/29/2022] [Indexed: 11/21/2022] Open
Abstract
Long-time ischemia worsening transplant outcomes in vascularized composite allotransplantation (VCA) is often neglected. Ischemia-reperfusion injury (IRI) is an inevitable event that follows reperfusion after a period of cold static storage. The pathophysiological mechanism activates local inflammation, which is a barrier to allograft long-term immune tolerance. The previous publications have not clearly described the relationship between the tissue damage and ischemia time, nor the rejection grade. In this review, we found that the rejection episodes and rejection grade are usually related to the ischemia time, both in clinical and experimental aspects. Moreover, we summarized the potential therapeutic measures to mitigate the ischemia-reperfusion injury. Compare to static preservation, machine perfusion is a promising method that can keep VCA tissue viability and extend preservation time, which is especially beneficial for the expansion of the donor pool and better MHC-matching.
Collapse
Affiliation(s)
- Jiqiang He
- Department of Hand and Microsurgery, Xiangya Hospital of Central South University, Changsha, China
| | - Umar Zeb Khan
- Department of Hand and Microsurgery, Xiangya Hospital of Central South University, Changsha, China
| | - Liming Qing
- Department of Hand and Microsurgery, Xiangya Hospital of Central South University, Changsha, China
| | - Panfeng Wu
- Department of Hand and Microsurgery, Xiangya Hospital of Central South University, Changsha, China
| | - Juyu Tang
- Department of Hand and Microsurgery, Xiangya Hospital of Central South University, Changsha, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital of Central South University, Changsha, China
| |
Collapse
|
11
|
Haug V, Diehm YF, Kneser U, Pomahac B. Some Like It Hot—a Commentary to Ex Vivo Normothermic Perfusion of Human Upper Limbs. Transplantation 2022; 106:1522-1523. [DOI: 10.1097/tp.0000000000004046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|