• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4617277)   Today's Articles (337)   Subscriber (49398)
For: Goker I, Baslo B, Ertas M, Ulgen Y. Large motor unit territories by scanning electromyography in patients with juvenile myoclonic epilepsy. J Clin Neurophysiol 2010;27:212-5. [PMID: 20461011 DOI: 10.1097/WNP.0b013e3181e0b228] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]  Open

Collapse
Number Cited by Other Article(s)
1
Acar D, Ozcelik EU, Baykan B, Bebek N, Demiralp T, Bayram A. Diffusion tensor imaging in photosensitive and nonphotosensitive juvenile myoclonic epilepsy. Seizure 2024;115:36-43. [PMID: 38183826 DOI: 10.1016/j.seizure.2023.12.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 11/27/2023] [Accepted: 12/22/2023] [Indexed: 01/08/2024]  Open
2
Masked least-squares averaging in processing of scanning-EMG recordings with multiple discharges. Med Biol Eng Comput 2020;58:3063-3073. [PMID: 33128161 DOI: 10.1007/s11517-020-02274-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Accepted: 10/06/2020] [Indexed: 10/23/2022]
3
Artuğ NT, Goker I, Bolat B, Osman O, Orhan EK, Baslo MB. New features for scanned bioelectrical activity of motor unit in health and disease. Biomed Signal Process Control 2018. [DOI: 10.1016/j.bspc.2017.11.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
4
A masked least-squares smoothing procedure for artifact reduction in scanning-EMG recordings. Med Biol Eng Comput 2018;56:1391-1402. [PMID: 29327334 PMCID: PMC6061514 DOI: 10.1007/s11517-017-1773-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2017] [Accepted: 12/13/2017] [Indexed: 02/08/2023]

The raw scanning-EMG signal (left figure) is processed by the MLSS algorithm in order to remove the artifact interference. Firstly, artifacts are detected from the raw signal, obtaining a validity mask (central figure) that determines the samples that have been contaminated by artifacts. Secondly, a least-squares smoothing procedure in the spatial dimension is applied to the raw signal using the not contaminated samples according to the validity mask. The resulting MLSS-processed scanning-EMG signal (right figure) is clean of artifact interference.

5
Classification of juvenile myoclonic epilepsy data acquired through scanning electromyography with machine learning algorithms. J Med Syst 2011;36:2705-11. [PMID: 21681512 DOI: 10.1007/s10916-011-9746-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2011] [Accepted: 06/02/2011] [Indexed: 12/31/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA