1
|
Castoldi NM, O'Rourke D, Antico M, Sansalone V, Gregory L, Pivonka P. Assessment of age-dependent sexual dimorphism in paediatric vertebral size and density using a statistical shape and statistical appearance modelling approach. Bone 2024; 189:117251. [PMID: 39251119 DOI: 10.1016/j.bone.2024.117251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 09/02/2024] [Accepted: 09/03/2024] [Indexed: 09/11/2024]
Abstract
This work focuses on the growth patterns of the human fourth lumbar vertebra (L4) in a paediatric population, with specific attention to sexual dimorphism. The study aims to understand morphological and density changes in the vertebrae through age-dependent statistical shape and statistical appearance models, which can describe full three-dimensional anatomy. Results show that the main growth patterns are associated with isotropic volumetric vertebral growth, a decrease in the relative size of the vertebral foramen, and an increase in the length of the transverse processes. Moreover, significant sexual dimorphism was demonstrated during puberty. We observe significant age and sex interaction in the anterior vertebral body height (P = 0.005), where females exhibited an earlier increase in rates of vertebral height evolution. Moreover, we also observe an increase in cross-sectional area (CSA) with age (P = 0.020), where the CSA is smaller in females than in males (significant sex effect P = 0.042). Finally, although no significant increase in trabecular bone density with age is observed (P = 0.363), a trend in the statistical appearance model suggests an increase in density with age.
Collapse
Affiliation(s)
- Natalia M Castoldi
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Australia; MSME UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, Creteil, France.
| | - Dermot O'Rourke
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Australia
| | - Maria Antico
- CSIRO Herston, Australian eHealth Research Centre, Brisbane, Australia
| | - Vittorio Sansalone
- MSME UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, Creteil, France
| | - Laura Gregory
- Clinical Anatomy and Paediatric Imaging, Queensland University of Technology, Brisbane, Australia
| | - Peter Pivonka
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Australia.
| |
Collapse
|
2
|
Ernstbrunner L, Robinson DL, Huang Y, Wieser K, Hoy G, Ek ET, Ackland DC. The Influence of Glenoid Bone Loss and Graft Positioning on Graft and Cartilage Contact Pressures After the Latarjet Procedure. Am J Sports Med 2023; 51:2454-2464. [PMID: 37724693 DOI: 10.1177/03635465231179711] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/21/2023]
Abstract
BACKGROUND Glenohumeral joint contact loading before and after glenoid bone grafting for recurrent anterior instability remains poorly understood. PURPOSE To develop a computational model to evaluate the influence of glenoid bone loss and graft positioning on graft and cartilage contact pressures after the Latarjet procedure. STUDY DESIGN Controlled laboratory study. METHODS A finite element model of the shoulder was developed using kinematics, muscle and glenohumeral joint loading of 6 male participants. Muscle and joint forces at 90° of abduction and external rotation were calculated and employed in simulations of the native shoulder, as well as the shoulder with a Bankart lesion, 10% and 25% glenoid bone loss, and after the Latarjet procedure. RESULTS A Bankart lesion as well as glenoid bone loss of 10% and 25% significantly increased glenoid and humeral cartilage contact pressures compared with the native shoulder (P < .05). The Latarjet procedure did not significantly increase glenoid cartilage contact pressure. With 25% glenoid bone loss, the Latarjet procedure with a graft flush with the glenoid and the humerus positioned at the glenoid half-width resulted in significantly increased humeral cartilage contact pressure compared with that preoperatively (P = .023). Under the same condition, medializing the graft by 1 mm resulted in humeral cartilage contact pressure comparable with that preoperatively (P = .097). Graft lateralization by 1 mm resulted in significantly increased humeral cartilage contact pressure in both glenoid bone loss conditions (P < .05). CONCLUSION This modeling study showed that labral damage and greater glenoid bone loss significantly increased glenoid and humeral cartilage contact pressures in the shoulder. The Latarjet procedure may mitigate this to an extent, although glenoid and humeral contact loading was sensitive to graft placement. CLINICAL RELEVANCE The Latarjet procedure with a correctly positioned graft should not lead to increased glenohumeral joint contact loading. The present study suggests that lateral graft overhang should be avoided, and in the situation of large glenoid bone defects, slight medialization (ie, 1 mm) of the graft may help to mitigate glenohumeral joint contact overloading.
Collapse
Affiliation(s)
- Lukas Ernstbrunner
- Department of Orthopaedic Surgery, Royal Melbourne Hospital, Parkville, Victoria, Australia
- Department of Biomedical Engineering, University of Melbourne, Parkville, Victoria, Australia
- Melbourne Orthopaedic Group, Windsor, Victoria, Australia
| | - Dale L Robinson
- Department of Biomedical Engineering, University of Melbourne, Parkville, Victoria, Australia
| | - Yichen Huang
- Department of Biomedical Engineering, University of Melbourne, Parkville, Victoria, Australia
| | - Karl Wieser
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - Greg Hoy
- Melbourne Orthopaedic Group, Windsor, Victoria, Australia
| | - Eugene T Ek
- Melbourne Orthopaedic Group, Windsor, Victoria, Australia
| | - David C Ackland
- Department of Biomedical Engineering, University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
3
|
Babazadeh Naseri A, Dunbar NJ, Baines AJ, Akin JE, Higgs Iii CF, Fregly BJ. Heterogeneous material mapping methods for patient-specific finite element models of pelvic trabecular bone: A convergence study. Med Eng Phys 2021; 96:1-12. [PMID: 34565547 DOI: 10.1016/j.medengphy.2021.07.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 07/18/2021] [Accepted: 07/20/2021] [Indexed: 12/17/2022]
Abstract
Patient-specific finite element (FE) models of bone require the assignment of heterogeneous material properties extracted from the subject's computed tomography (CT) images. Though node-based (NB) and element-based (EB) material mapping methods (MMMs) have been proposed, the sensitivity and convergence of FE models to MMM for varying mesh sizes are not well understood. In this work, CT-derived and synthetic bone material data were used to evaluate the effect of MMM on results from FE analyses. Pelvic trabecular bone data was extracted from CT images of six subjects, while synthetic data were created to resemble trabecular bone properties. The numerical convergence of FE bone models using different MMMs were evaluated for strain energy, von-Mises stress, and strain. NB and EB MMMs both demonstrated good convergence regarding total strain energy, with the EB method having a slight edge over the NB. However, at the local level (e.g., maximum stress and strain), FE results were sensitive to the field type, MMM, and the FE mesh size. The EB method exhibited superior performance in finer meshes relative to the voxel size. The NB method converged better than did the EB method for coarser meshes. These findings may lead to higher-fidelity patient-specific FE bone models.
Collapse
Affiliation(s)
| | - Nicholas J Dunbar
- Department of Mechanical Engineering, Rice University, Houston, TX 77005, USA
| | - Andrew J Baines
- Department of Mechanical Engineering, Rice University, Houston, TX 77005, USA
| | - John E Akin
- Department of Mechanical Engineering, Rice University, Houston, TX 77005, USA
| | - C Fred Higgs Iii
- Department of Mechanical Engineering, Rice University, Houston, TX 77005, USA
| | - Benjamin J Fregly
- Department of Mechanical Engineering, Rice University, Houston, TX 77005, USA.
| |
Collapse
|
4
|
Reeves JM, Knowles NK, Athwal GS, Johnson JA. Methods for Post Hoc Quantitative Computed Tomography Bone Density Calibration: Phantom-Only and Regression. J Biomech Eng 2019; 140:2680998. [PMID: 29801170 DOI: 10.1115/1.4040122] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2017] [Indexed: 11/08/2022]
Abstract
Quantitative computed tomography (qCT) relies on calibrated bone mineral density data. If a calibration phantom is absent from the CT scan, post hoc calibration becomes necessary. Scanning a calibration phantom after-the-fact and applying that calibration to uncalibrated scans has been used previously. Alternatively, the estimated density is known to vary with CT settings, suggesting that it may be possible to predict the calibration terms using CT settings. This study compares a novel CT setting regression method for post hoc calibration to standard and post hoc phantom-only calibrations. Five cadaveric upper limbs were scanned at 11 combinations of peak tube voltage and current (80-140 kV and 100-300 mA) with two calibration phantoms. Density calibrations were performed for the cadaver scans, and scans of the phantoms alone. Stepwise linear regression determined if the calibration equation terms were predictable using peak tube voltage and current. Peak tube voltage, but not current, was significantly correlated with regression calibration terms. Calibration equation slope was significantly related to the type of phantom (p < 0.001), calibration method (p = 0.026), and peak tube voltage (p < 0.001), but not current (p = 1.000). The calibration equation vertical intercept was significantly related to the type of phantom (p < 0.001), and peak tube voltage (p = 0.006), but not calibration method (p = 0.682), or current (p = 0.822). Accordingly, regression can correlate peak tube voltage with density calibration terms. Suggesting that, while standard qCT calibration is preferable, regression calibration may be an acceptable post hoc method when necessary.
Collapse
Affiliation(s)
- Jacob M Reeves
- Department of Mechanical Engineering, Western University Canada, 1151 Richmond Street, London, ON N6A3K7, Canada e-mail:
| | - Nikolas K Knowles
- Department of Biomedical Engineering, Western University Canada, 1151 Richmond Street, London, ON N6A3K7, Canada e-mail:
| | - George S Athwal
- Roth
- McFarlane Hand and Upper Limb Centre, 268 Grosvenor Street, London, ON N6A4V2, Canada e-mail:
| | - James A Johnson
- Department of Mechanical Engineering, Western University Canada, 1151 Richmond Street, London, ON N6A3K7, Canada e-mail:
| |
Collapse
|
5
|
Emuna N, Durban D, Osovski S. Sensitivity of Arterial Hyperelastic Models to Uncertainties in Stress-Free Measurements. J Biomech Eng 2019; 140:2683233. [PMID: 30029245 DOI: 10.1115/1.4040400] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2017] [Indexed: 12/14/2022]
Abstract
Despite major advances made in modeling vascular tissue biomechanics, the predictive power of constitutive models is still limited by uncertainty of the input data. Specifically, key measurements, like the geometry of the stress-free (SF) state, involve a definite, sometimes non-negligible, degree of uncertainty. Here, we introduce a new approach for sensitivity analysis of vascular hyperelastic constitutive models to uncertainty in SF measurements. We have considered two vascular hyperelastic models: the phenomenological Fung model and the structure-motivated Holzapfel-Gasser-Ogden (HGO) model. Our results indicate up to 160% errors in the identified constitutive parameters for a 5% measurement uncertainty in the SF data. Relative margins of errors of up to 30% in the luminal pressure, 36% in the axial force, and over 200% in the stress predictions were recorded for 10% uncertainties. These findings are relevant to the large body of studies involving experimentally based modeling and analysis of vascular tissues. The impact of uncertainties on calibrated constitutive parameters is significant in context of studies that use constitutive parameters to draw conclusions about the underlying microstructure of vascular tissues, their growth and remodeling processes, and aging and disease states. The propagation of uncertainties into the predictions of biophysical parameters, e.g., force, luminal pressure, and wall stresses, is of practical importance in the design and execution of clinical devices and interventions. Furthermore, insights provided by the present findings may lead to more robust parameters identification techniques, and serve as selection criteria in the trade-off between model complexity and sensitivity.
Collapse
Affiliation(s)
- Nir Emuna
- Faculty of Aerospace Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel e-mail:
| | - David Durban
- Faculty of Aerospace Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel e-mail:
| | - Shmuel Osovski
- Faculty of Mechanical Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel e-mail:
| |
Collapse
|
6
|
Zheng M, Zou Z, Bartolo PJDS, Peach C, Ren L. Finite element models of the human shoulder complex: a review of their clinical implications and modelling techniques. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2017; 33:e02777. [PMID: 26891250 PMCID: PMC5297878 DOI: 10.1002/cnm.2777] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2015] [Revised: 02/11/2016] [Accepted: 02/12/2016] [Indexed: 05/05/2023]
Abstract
The human shoulder is a complicated musculoskeletal structure and is a perfect compromise between mobility and stability. The objective of this paper is to provide a thorough review of previous finite element (FE) studies in biomechanics of the human shoulder complex. Those FE studies to investigate shoulder biomechanics have been reviewed according to the physiological and clinical problems addressed: glenohumeral joint stability, rotator cuff tears, joint capsular and labral defects and shoulder arthroplasty. The major findings, limitations, potential clinical applications and modelling techniques of those FE studies are critically discussed. The main challenges faced in order to accurately represent the realistic physiological functions of the shoulder mechanism in FE simulations involve (1) subject-specific representation of the anisotropic nonhomogeneous material properties of the shoulder tissues in both healthy and pathological conditions; (2) definition of boundary and loading conditions based on individualised physiological data; (3) more comprehensive modelling describing the whole shoulder complex including appropriate three-dimensional (3D) representation of all major shoulder hard tissues and soft tissues and their delicate interactions; (4) rigorous in vivo experimental validation of FE simulation results. Fully validated shoulder FE models would greatly enhance our understanding of the aetiology of shoulder disorders, and hence facilitate the development of more efficient clinical diagnoses, non-surgical and surgical treatments, as well as shoulder orthotics and prosthetics. © 2016 The Authors. International Journal for Numerical Methods in Biomedical Engineering published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- Manxu Zheng
- School of Mechanical, Aerospace and Civil EngineeringUniversity of ManchesterManchesterM13 9PLUK
| | - Zhenmin Zou
- School of Mechanical, Aerospace and Civil EngineeringUniversity of ManchesterManchesterM13 9PLUK
| | | | - Chris Peach
- School of Mechanical, Aerospace and Civil EngineeringUniversity of ManchesterManchesterM13 9PLUK
- The University Hospital of South Manchester NHS Foundation TrustSouthmoor RoadWythenshaweManchesterM23 9LTUK
| | - Lei Ren
- School of Mechanical, Aerospace and Civil EngineeringUniversity of ManchesterManchesterM13 9PLUK
| |
Collapse
|
7
|
Knowles NK, Reeves JM, Ferreira LM. Quantitative Computed Tomography (QCT) derived Bone Mineral Density (BMD) in finite element studies: a review of the literature. J Exp Orthop 2016; 3:36. [PMID: 27943224 PMCID: PMC5234499 DOI: 10.1186/s40634-016-0072-2] [Citation(s) in RCA: 60] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Accepted: 11/30/2016] [Indexed: 01/23/2023] Open
Abstract
BACKGROUND Finite element modeling of human bone provides a powerful tool to evaluate a wide variety of outcomes in a highly repeatable and parametric manner. These models are most often derived from computed tomography data, with mechanical properties related to bone mineral density (BMD) from the x-ray energy attenuation provided from this data. To increase accuracy, many researchers report the use of quantitative computed tomography (QCT), in which a calibration phantom is used during image acquisition to improve the estimation of BMD. Since model accuracy is dependent on the methods used in the calculation of BMD and density-mechanical property relationships, it is important to use relationships developed for the same anatomical location and using the same scanner settings, as these may impact model accuracy. The purpose of this literature review is to report the relationships used in the conversion of QCT equivalent density measures to ash, apparent, and/or tissue densities in recent finite element (FE) studies used in common density-modulus relationships. For studies reporting experimental validation, the validation metrics and results are presented. RESULTS Of the studies reviewed, 29% reported the use of a dipotassium phosphate (K2HPO4) phantom, 47% a hydroxyapatite (HA) phantom, 13% did not report phantom type, 7% reported use of both K2HPO4 and HA phantoms, and 4% alternate phantom types. Scanner type and/or settings were omitted or partially reported in 31% of studies. The majority of studies used densitometric and/or density-modulus relationships derived from different anatomical locations scanned in different scanners with different scanner settings. The methods used to derive various densitometric relationships are reported and recommendations are provided toward the standardization of reporting metrics. CONCLUSIONS This review assessed the current state of QCT-based FE modeling with use of clinical scanners. It was found that previously developed densitometric relationships vary by anatomical location, scanner type and settings. Reporting of all parameters used when referring to previously developed relationships, or in the development of new relationships, may increase the accuracy and repeatability of future FE models.
Collapse
Affiliation(s)
- Nikolas K. Knowles
- Graduate Program in Biomedical Engineering, The University of Western Ontario, 1151 Richmond St, London, ON Canada
- Roth|McFarlane Hand and Upper Limb Centre, Surgical Mechatronics
Laboratory, St. Josephs Health Care, 268 Grosvenor St, London, ON Canada
- Collaborative Training Program in Musculoskeletal Health Research, and
Bone and Joint Institute, The University of Western Ontario, 1151 Richmond St, London, ON Canada
| | - Jacob M. Reeves
- Roth|McFarlane Hand and Upper Limb Centre, Surgical Mechatronics
Laboratory, St. Josephs Health Care, 268 Grosvenor St, London, ON Canada
- Collaborative Training Program in Musculoskeletal Health Research, and
Bone and Joint Institute, The University of Western Ontario, 1151 Richmond St, London, ON Canada
- Department of Mechanical and Materials Engineering, The University of Western Ontario, 1151 Richmond St, London, ON Canada
| | - Louis M. Ferreira
- Graduate Program in Biomedical Engineering, The University of Western Ontario, 1151 Richmond St, London, ON Canada
- Roth|McFarlane Hand and Upper Limb Centre, Surgical Mechatronics
Laboratory, St. Josephs Health Care, 268 Grosvenor St, London, ON Canada
- Collaborative Training Program in Musculoskeletal Health Research, and
Bone and Joint Institute, The University of Western Ontario, 1151 Richmond St, London, ON Canada
| |
Collapse
|
8
|
Cloud-Based Automated Design and Additive Manufacturing: A Usage Data-Enabled Paradigm Shift. SENSORS 2015; 15:32079-122. [PMID: 26703606 PMCID: PMC4721822 DOI: 10.3390/s151229905] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2015] [Revised: 12/09/2015] [Accepted: 12/16/2015] [Indexed: 11/17/2022]
Abstract
Integration of sensors into various kinds of products and machines provides access to in-depth usage information as basis for product optimization. Presently, this large potential for more user-friendly and efficient products is not being realized because (a) sensor integration and thus usage information is not available on a large scale and (b) product optimization requires considerable efforts in terms of manpower and adaptation of production equipment. However, with the advent of cloud-based services and highly flexible additive manufacturing techniques, these obstacles are currently crumbling away at rapid pace. The present study explores the state of the art in gathering and evaluating product usage and life cycle data, additive manufacturing and sensor integration, automated design and cloud-based services in manufacturing. By joining and extrapolating development trends in these areas, it delimits the foundations of a manufacturing concept that will allow continuous and economically viable product optimization on a general, user group or individual user level. This projection is checked against three different application scenarios, each of which stresses different aspects of the underlying holistic concept. The following discussion identifies critical issues and research needs by adopting the relevant stakeholder perspectives.
Collapse
|
9
|
Püschel TA, Sellers WI. Standing on the shoulders of apes: Analyzing the form and function of the hominoid scapula using geometric morphometrics and finite element analysis. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY 2015; 159:325-41. [DOI: 10.1002/ajpa.22882] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2014] [Revised: 09/02/2015] [Accepted: 10/01/2015] [Indexed: 12/30/2022]
Affiliation(s)
- Thomas A. Püschel
- Computational and Evolutionary Biology Group, Faculty of Life Sciences; University of Manchester; Manchester M13 9PT UK
| | - William I. Sellers
- Computational and Evolutionary Biology Group, Faculty of Life Sciences; University of Manchester; Manchester M13 9PT UK
| |
Collapse
|
10
|
VAN DEN MUNCKHOF SVEN, NIKOOYAN ALIASADI, ZADPOOR AMIRABBAS. ASSESSMENT OF OSTEOPOROTIC FEMORAL FRACTURE RISK: FINITE ELEMENT METHOD AS A POTENTIAL REPLACEMENT FOR CURRENT CLINICAL TECHNIQUES. J MECH MED BIOL 2015. [DOI: 10.1142/s0219519415300033] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Femoral fracture risk prediction is a necessary step preceding effective pharmacological intervention or pre-operative planning. Current clinical methods for fracture risk prediction rely on 2D imaging methods and have limited predictive value. Researchers are therefore trying to find improved methods for fracture prediction. During last few decades, many studies have focused on integration of 3D imaging techniques and the finite element (FE) method to improve the accuracy of fracture assessment techniques. In this paper, we review the recent advances in FE and other techniques for predicting the risk of femoral fractures. Based on a number of selected studies, the different steps that are involved in generation of patient-specific FE models are reviewed with particular emphasis on the fracture criteria. The inaccuracies that might arise due to the imperfections of the involved steps are also discussed. It is concluded that compared to image- and geometry-based techniques, FE is a more promising approach for prediction of fracture loads. However, certain technological advancements in FE modeling protocols are required before FE modeling can be recruited in clinical settings.
Collapse
Affiliation(s)
- SVEN VAN DEN MUNCKHOF
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, Delft 2628 CD, The Netherlands
| | - ALI ASADI NIKOOYAN
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, Delft 2628 CD, The Netherlands
- Department of Integrative Physiology, University of Colorado, Boulder, CO 80309, USA
| | - AMIR ABBAS ZADPOOR
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, Delft 2628 CD, The Netherlands
| |
Collapse
|
11
|
Patient-specific bone modeling and analysis: the role of integration and automation in clinical adoption. J Biomech 2014; 48:750-60. [PMID: 25547022 DOI: 10.1016/j.jbiomech.2014.12.018] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/26/2014] [Indexed: 12/11/2022]
Abstract
Patient-specific analysis of bones is considered an important tool for diagnosis and treatment of skeletal diseases and for clinical research aimed at understanding the etiology of skeletal diseases and the effects of different types of treatment on their progress. In this article, we discuss how integration of several important components enables accurate and cost-effective patient-specific bone analysis, focusing primarily on patient-specific finite element (FE) modeling of bones. First, the different components are briefly reviewed. Then, two important aspects of patient-specific FE modeling, namely integration of modeling components and automation of modeling approaches, are discussed. We conclude with a section on validation of patient-specific modeling results, possible applications of patient-specific modeling procedures, current limitations of the modeling approaches, and possible areas for future research.
Collapse
|
12
|
Campoli G, Baka N, Kaptein BL, Valstar ER, Zachow S, Weinans H, Zadpoor AA. Relationship between the shape and density distribution of the femur and its natural frequencies of vibration. J Biomech 2014; 47:3334-43. [PMID: 25171786 DOI: 10.1016/j.jbiomech.2014.08.008] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2014] [Revised: 08/04/2014] [Accepted: 08/08/2014] [Indexed: 11/17/2022]
Abstract
It has been recently suggested that mechanical loads applied at frequencies close to the natural frequencies of bone could enhance bone apposition due to the resonance phenomenon. Other applications of bone modal analysis are also suggested. For the above-mentioned applications, it is important to understand how patient-specific bone shape and density distribution influence the natural frequencies of bones. We used finite element models to study the effects of bone shape and density distribution on the natural frequencies of the femur in free boundary conditions. A statistical shape and appearance model that describes shape and density distribution independently was created, based on a training set of 27 femora. The natural frequencies were then calculated for different shape modes varied around the mean shape while keeping the mean density distribution, for different appearance modes around the mean density distribution while keeping the mean bone shape, and for the 27 training femora. Single shape or appearance modes could cause up to 15% variations in the natural frequencies with certain modes having the greatest impact. For the actual femora, shape and density distribution changed the natural frequencies by up to 38%. First appearance mode that describes the general cortical bone thickness and trabecular bone density had one of the strongest impacts. The first appearance mode could therefore provide a sensitive measure of general bone health and disease progression. Since shape and density could cause large variations in the calculated natural frequencies, patient-specific FE models are needed for accurate estimation of bone natural frequencies.
Collapse
Affiliation(s)
- G Campoli
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, Delft 2628 CD, The Netherlands
| | - N Baka
- Biomechanics and Imaging Group, Department of Orthopaedics, Leiden University Medical Center, P.O. Box 9600, 2300 RC Leiden, The Netherlands
| | - B L Kaptein
- Biomechanics and Imaging Group, Department of Orthopaedics, Leiden University Medical Center, P.O. Box 9600, 2300 RC Leiden, The Netherlands
| | - E R Valstar
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, Delft 2628 CD, The Netherlands; Biomechanics and Imaging Group, Department of Orthopaedics, Leiden University Medical Center, P.O. Box 9600, 2300 RC Leiden, The Netherlands
| | - S Zachow
- Visualization & Data Analysis Medical Planning & Computational Medicine Groups, Zuse Institute Berlin (ZIB), Berlin, Germany
| | - H Weinans
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, Delft 2628 CD, The Netherlands; Departments of Orthopedics and Rheumatology, Utrecht University Medical Center, Utrecht, The Netherlands
| | - A A Zadpoor
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, Delft 2628 CD, The Netherlands.
| |
Collapse
|