1
|
Ludwig A, Rivera C, Uvarov P. A noninvasive optical approach for assessing chloride extrusion activity of the K-Cl cotransporter KCC2 in neuronal cells. BMC Neurosci 2017; 18:23. [PMID: 28143398 PMCID: PMC5286847 DOI: 10.1186/s12868-017-0336-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2016] [Accepted: 01/12/2017] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND Cation-chloride cotransporters (CCCs) are indispensable for maintaining chloride homeostasis in multiple cell types, but K-Cl cotransporter KCC2 is the only CCC member with an exclusively neuronal expression in mammals. KCC2 is critical for rendering fast hyperpolarizing responses of ionotropic γ-aminobutyric acid and glycine receptors in adult neurons, for neuronal migration in the developing central nervous system, and for the formation and maintenance of small dendritic protrusions-dendritic spines. Deficit in KCC2 expression and/or activity is associated with epilepsy and neuropathic pain, and effective strategies are required to search for novel drugs augmenting KCC2 function. RESULTS We revised current methods to develop a noninvasive optical approach for assessing KCC2 transport activity using a previously characterized genetically encoded chloride sensor. Our protocol directly assesses dynamics of KCC2-mediated chloride efflux and allows measuring genuine KCC2 activity with good spatial and temporal resolution. As a proof of concept, we used this approach to compare transport activities of the two known KCC2 splice isoforms, KCC2a and KCC2b, in mouse neuronal Neuro-2a cells. CONCLUSIONS Our noninvasive optical protocol proved to be efficient for assessment of furosemide-sensitive chloride fluxes. Transport activities of the N-terminal splice isoforms KCC2a and KCC2b obtained by the novel approach matched to those reported previously using standard methods for measuring chloride fluxes.
Collapse
Affiliation(s)
- Anastasia Ludwig
- Neuroscience Center, University of Helsinki, Helsinki, Finland
- École Normale Supérieure, Institut de Biologie de l’ENS (IBENS), INSERM U1024, CNRS 8197, Paris, France
| | - Claudio Rivera
- Neuroscience Center, University of Helsinki, Helsinki, Finland
- INSERM U901, Institut de Neurobiologie de la Méditerranée (INMED), Marseille, France
- UMR S901, Aix-Marseille Université, Marseille, France
| | - Pavel Uvarov
- Department of Anatomy, Faculty of Medicine, University of Helsinki, Helsinki, Finland
- Department of Biosciences and Neuroscience Center, University of Helsinki, Helsinki, Finland
| |
Collapse
|
2
|
Notelaers K, Rocha S, Paesen R, Swinnen N, Vangindertael J, Meier JC, Rigo JM, Ameloot M, Hofkens J. Membrane distribution of the glycine receptor α3 studied by optical super-resolution microscopy. Histochem Cell Biol 2014; 142:79-90. [PMID: 24553792 DOI: 10.1007/s00418-014-1197-y] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/09/2014] [Indexed: 11/24/2022]
Abstract
In this study, the effect of glycine receptor (GlyR) α3 alternative RNA splicing on the distribution of receptors in the membrane of human embryonic kidney 293 cells is investigated using optical super-resolution microscopy. Direct stochastic optical reconstruction microscopy is used to image both α3K and α3L splice variants individually and together using single- and dual-color imaging. Pair correlation analysis is used to extract quantitative measures from the resulting images. Autocorrelation analysis of the individually expressed variants reveals clustering of both variants, yet with differing properties. The cluster size is increased for α3L compared to α3K (mean radius 92 ± 4 and 56 ± 3 nm, respectively), yet an even bigger difference is found in the cluster density (9,870 ± 1,433 and 1,747 ± 200 μm(-2), respectively). Furthermore, cross-correlation analysis revealed that upon co-expression, clusters colocalize on the same spatial scales as for individually expressed receptors (mean co-cluster radius 94 ± 6 nm). These results demonstrate that RNA splicing determines GlyR α3 membrane distribution, which has consequences for neuronal GlyR physiology and function.
Collapse
Affiliation(s)
- Kristof Notelaers
- Biomedical Research Institute, Hasselt University and School of Life Sciences, Transnational University Limburg, Agoralaan Gebouw C, 3590, Diepenbeek, Belgium
| | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Batti L, Mukhtarov M, Audero E, Ivanov A, Paolicelli RC, Zurborg S, Gross C, Bregestovski P, Heppenstall PA. Transgenic mouse lines for non-invasive ratiometric monitoring of intracellular chloride. Front Mol Neurosci 2013; 6:11. [PMID: 23734096 PMCID: PMC3659292 DOI: 10.3389/fnmol.2013.00011] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2013] [Accepted: 04/26/2013] [Indexed: 11/13/2022] Open
Abstract
Chloride is the most abundant physiological anion and participates in a variety of cellular processes including trans-epithelial transport, cell volume regulation, and regulation of electrical excitability. The development of tools to monitor intracellular chloride concentration ([Cli]) is therefore important for the evaluation of cellular function in normal and pathological conditions. Recently, several Cl-sensitive genetically encoded probes have been described which allow for non-invasive monitoring of [Cli]. Here we describe two mouse lines expressing a CFP-YFP-based Cl probe called Cl-Sensor. First, we generated transgenic mice expressing Cl-Sensor under the control of the mouse Thy1 mini promoter. Cl-Sensor exhibited good expression from postnatal day two (P2) in neurons of the hippocampus and cortex, and its level increased strongly during development. Using simultaneous whole-cell monitoring of ionic currents and Cl-dependent fluorescence, we determined that the apparent EC 50 for Cli was 46 mM, indicating that this line is appropriate for measuring neuronal [Cli] in postnatal mice. We also describe a transgenic mouse reporter line for Cre-dependent conditional expression of Cl-Sensor, which was targeted to the Rosa26 locus and by incorporating a strong exogenous promoter induced robust expression upon Cre-mediated recombination. We demonstrate high levels of tissue-specific expression in two different Cre-driver lines targeting cells of the myeloid lineage and peripheral sensory neurons. Using these mice the apparent EC 50 for Cli was estimated to be 61 and 54 mM in macrophages and DRG, respectively. Our data suggest that these mouse lines will be useful models for ratiometric monitoring of Cli in specific cell types in vivo.
Collapse
Affiliation(s)
- Laura Batti
- Mouse Biology Unit, European Molecular Biology Laboratory Monterotondo, Italy
| | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Mukhtarov M, Liguori L, Waseem T, Rocca F, Buldakova S, Arosio D, Bregestovski P. Calibration and functional analysis of three genetically encoded Cl(-)/pH sensors. Front Mol Neurosci 2013; 6:9. [PMID: 23616745 PMCID: PMC3629305 DOI: 10.3389/fnmol.2013.00009] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2013] [Accepted: 04/02/2013] [Indexed: 11/29/2022] Open
Abstract
Monitoring of the intracellular concentrations of Cl− and H+ requires sensitive probes that allow reliable quantitative measurements without perturbation of cell functioning. For these purposes the most promising are genetically encoded fluorescent biosensors, which have become powerful tools for non-invasive intracellular monitoring of ions, molecules, and enzymatic activity. A ratiometric CFP/YFP-based construct with a relatively good sensitivity to Cl− has been developed (Markova et al., 2008; Waseem et al., 2010). Recently, a combined Cl−/pH sensor (ClopHensor) opened the way for simultaneous ratiometric measurement of these two ions (Arosio et al., 2010). ClopHensor was obtained by fusion of a red-fluorescent protein (DsRed-monomer) to the E2GFP variant that contains a specific Cl−-binding site. This construct possesses pKa = 6.8 for H+ and Kd in the 40–50 mM range for Cl− at physiological pH (~7.3). As in the majority of cell types the intracellular Cl− concentration ([Cl−]i) is about 10 mM, the development of sensors with higher sensitivity is highly desirable. Here, we report the intracellular calibration and functional characterization of ClopHensor and its two derivatives: the membrane targeting PalmPalm-ClopHensor and the H148G/V224L mutant with improved Cl− affinity, reduced pH dependence, and pKa shifted to more alkaline values. For functional analysis, constructs were expressed in CHO cells and [Cl−]i was changed by using pipettes with different Cl− concentrations during whole-cell recordings. Kd values for Cl− measured at 33°C and pH ~7.3 were, respectively, 39, 47, and 21 mM for ClopHensor, PalmPalm-ClopHensor, and the H148G/V224L mutant. PalmPalm-ClopHensor resolved responses to activation of Cl−-selective glycine receptor (GlyR) channels better than did ClopHensor. Our observations indicate that these different ClopHensor constructs are promising tools for non-invasive measurement of [Cl−]i in various living cells.
Collapse
Affiliation(s)
- M Mukhtarov
- Brain Dynamics Institute, Inserm UMR1106, Aix-Marseille University Marseille, France ; Laboratory of Neurobiology, Institute of Fundamental Medicine and Biology, Kazan Federal University Kazan, Russia
| | | | | | | | | | | | | |
Collapse
|
5
|
Kovalchuk Y, Garaschuk O. Two-photon chloride imaging using MQAE in vitro and in vivo. Cold Spring Harb Protoc 2012; 2012:778-85. [PMID: 22753606 DOI: 10.1101/pdb.prot070037] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
This protocol describes a technique for high-resolution chloride imaging of living cells using a quinoline-based chloride (Cl(-)) indicator dye, MQAE (N-[6-methoxyquinolyl] acetoethyl ester). Bath-applied to acute brain slices, MQAE provides high-quality labeling of neuronal cells and their processes. In living anesthetized mice, cortical cells are labeled using the multicell bolus loading procedure. In combination with two-photon microscopy, this procedure enables in vivo visualization of cell bodies of neurons and astrocytes as well as some astrocytic processes and allows one to monitor changes in the intracellular chloride concentration in dozens of individual cells.
Collapse
|
6
|
Cangiano L, Asteriti S, Cervetto L, Gargini C. The photovoltage of rods and cones in the dark-adapted mouse retina. J Physiol 2012; 590:3841-55. [PMID: 22641773 DOI: 10.1113/jphysiol.2011.226878] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Research on photoreceptors has led to important insights into how light signals are detected and processed in the outer retina. Most information about photoreceptor function, however, comes from lower vertebrates. The large majority of mammalian studies are based on suction pipette recordings of outer segment currents, a technique that doesn't allow examination of phenomena occurring downstream of phototransduction. Only a small number of whole-cell recordings have been made, mainly in the macaque. Due to the growing importance of the mouse in vision research, we have optimized a retinal slice preparation that allows the reliable collection of perforated-patch recordings from light responding rods and cones. Unexpectedly, the frequency of cone recordings was much higher than their numeric proportion of ∼3%. This allowed us to obtain direct functional evidence suggestive of rod–cone coupling in the mouse. Moreover, rods had considerably larger single photon responses than previously published for mammals (3.44 mV, SD 1.37, n = 19 at 24°C; 2.46 mV, SD 1.08, n = 10 at 36°C), and a relatively high signal/noise ratio (6.4, SD 1.8 at 24°C; 6.8, SD 2.8 at 36°C). Both findings imply a more favourable transmission at the rod–rod bipolar cell synapse. Accordingly, relatively few photoisomerizations were sufficient to elicit a half-maximal response (6.7, SD 2.7, n = 5 at 24°C; 10.6, SD 1.7, n = 3 at 36°C), leading to a narrow linear response range. Our study demonstrates new features of mammalian photoreceptors and opens the way for further investigations into photoreceptor function using retinas from mutant mouse models.
Collapse
Affiliation(s)
- Lorenzo Cangiano
- Department of Physiological Sciences, University of Pisa, Via San Zeno 31, I-56123 Pisa, Italy.
| | | | | | | |
Collapse
|
7
|
Optogenetic reporters: Fluorescent protein-based genetically encoded indicators of signaling and metabolism in the brain. PROGRESS IN BRAIN RESEARCH 2012; 196:235-63. [PMID: 22341329 DOI: 10.1016/b978-0-444-59426-6.00012-4] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Fluorescent protein technology has evolved to include genetically encoded biosensors that can monitor levels of ions, metabolites, and enzyme activities as well as protein conformation and even membrane voltage. They are well suited to live-cell microscopy and quantitative analysis, and they can be used in multiple imaging modes, including one- or two-photon fluorescence intensity or lifetime microscopy. Although not nearly complete, there now exists a substantial set of genetically encoded reporters that can be used to monitor many aspects of neuronal and glial biology, and these biosensors can be used to visualize synaptic transmission and activity-dependent signaling in vitro and in vivo. In this review, we present an overview of design strategies for engineering biosensors, including sensor designs using circularly permuted fluorescent proteins and using fluorescence resonance energy transfer between fluorescent proteins. We also provide examples of indicators that sense small ions (e.g., pH, chloride, zinc), metabolites (e.g., glutamate, glucose, ATP, cAMP, lipid metabolites), signaling pathways (e.g., G protein-coupled receptors, Rho GTPases), enzyme activities (e.g., protein kinase A, caspases), and reactive species. We focus on examples where these genetically encoded indicators have been applied to brain-related studies and used with live-cell fluorescence microscopy.
Collapse
|
8
|
Plank C, Zelphati O, Mykhaylyk O. Magnetically enhanced nucleic acid delivery. Ten years of magnetofection-progress and prospects. Adv Drug Deliv Rev 2011; 63:1300-31. [PMID: 21893135 PMCID: PMC7103316 DOI: 10.1016/j.addr.2011.08.002] [Citation(s) in RCA: 251] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2011] [Revised: 08/18/2011] [Accepted: 08/19/2011] [Indexed: 12/28/2022]
Abstract
Nucleic acids carry the building plans of living systems. As such, they can be exploited to make cells produce a desired protein, or to shut down the expression of endogenous genes or even to repair defective genes. Hence, nucleic acids are unique substances for research and therapy. To exploit their potential, they need to be delivered into cells which can be a challenging task in many respects. During the last decade, nanomagnetic methods for delivering and targeting nucleic acids have been developed, methods which are often referred to as magnetofection. In this review we summarize the progress and achievements in this field of research. We discuss magnetic formulations of vectors for nucleic acid delivery and their characterization, mechanisms of magnetofection, and the application of magnetofection in viral and nonviral nucleic acid delivery in cell culture and in animal models. We summarize results that have been obtained with using magnetofection in basic research and in preclinical animal models. Finally, we describe some of our recent work and end with some conclusions and perspectives.
Collapse
|
9
|
|
10
|
Green Fluorescent Protein-Based Chloride Ion Sensors for In Vivo Imaging. FLUORESCENT PROTEINS II 2011. [DOI: 10.1007/4243_2011_27] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
11
|
Genetically encoded Cl-Sensor as a tool for monitoring of Cl-dependent processes in small neuronal compartments. J Neurosci Methods 2010; 193:14-23. [PMID: 20705097 DOI: 10.1016/j.jneumeth.2010.08.002] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2010] [Revised: 08/02/2010] [Accepted: 08/03/2010] [Indexed: 12/21/2022]
Abstract
Chloride (Cl) participates in a variety of physiological functions. To study processes connected with Cl homeostasis we need effective and quantitative probes allowing measurements of intracellular Cl concentration ([Cl(-)](i)) in different cell types, particularly in specialized small cellular compartments such as dendrites and dendritic spines. Of the different tools proposed for monitoring [Cl(-)](i), the genetically encoded Cl-sensitive indicators are the most promising. Recently, a ratiometric CFP-YFP based construct, termed "Cl-Sensor", with a relatively high sensitivity to Cl has been proposed (Markova et al., 2008). In the present study, we have developed conditions for the efficient expression of Cl-Sensor in tiny neuronal compartments including distal dendrites and spines. We also propose a new approach for the calibration of intracellularly expressed probes using a natural triterpenoid saponin, β-escin. We have mapped [Cl(-)](i) distribution in different neuronal compartments of cultured hippocampal and spinal cord neurons. The maximum Cl concentration was observed in the soma and it had a tendency to decrease gradually along dendritic branches, reaching minimum values in thin distal dendrites. We have also monitored transient increases in intracellular Cl in dendritic spines caused by glutamate application. These results demonstrate that Cl-Sensor enables non-invasive monitoring of the [Cl(-)](i) distribution in different types of neurons with variable morphology. This probe represents an effective tool for the quantitative estimation of [Cl(-)](i) in various cellular compartments including dendritic spines.
Collapse
|
12
|
Bregestovski P, Waseem T, Mukhtarov M. Genetically encoded optical sensors for monitoring of intracellular chloride and chloride-selective channel activity. Front Mol Neurosci 2009; 2:15. [PMID: 20057911 PMCID: PMC2802328 DOI: 10.3389/neuro.02.015.2009] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2009] [Accepted: 08/28/2009] [Indexed: 12/31/2022] Open
Abstract
This review briefly discusses the main approaches for monitoring chloride (Cl−), the most abundant physiological anion. Noninvasive monitoring of intracellular Cl− ([Cl−]i) is a challenging task owing to two main difficulties: (i) the low transmembrane ratio for Cl−, approximately 10:1; and (ii) the small driving force for Cl−, as the Cl− reversal potential (ECl) is usually close to the resting potential of the cells. Thus, for reliable monitoring of intracellular Cl−, one has to use highly sensitive probes. From several methods for intracellular Cl− analysis, genetically encoded chloride indicators represent the most promising tools. Recent achievements in the development of genetically encoded chloride probes are based on the fact that yellow fluorescent protein (YFP) exhibits Cl−-sensitivity. YFP-based probes have been successfully used for quantitative analysis of Cl− transport in different cells and for high-throughput screening of modulators of Cl−-selective channels. Development of a ratiometric genetically encoded probe, Clomeleon, has provided a tool for noninvasive estimation of intracellular Cl− concentrations. While the sensitivity of this protein to Cl− is low (EC50 about 160 mM), it has been successfully used for monitoring intracellular Cl− in different cell types. Recently a CFP–YFP-based probe with a relatively high sensitivity to Cl− (EC50 about 30 mM) has been developed. This construct, termed Cl-Sensor, allows ratiometric monitoring using the fluorescence excitation ratio. Of particular interest are genetically encoded probes for monitoring of ion channel distribution and activity. A new molecular probe has been constructed by introducing into the cytoplasmic domain of the Cl−-selective glycine receptor (GlyR) channel the CFP–YFP-based Cl-Sensor. This construct, termed BioSensor-GlyR, has been successfully expressed in cell lines. The new genetically encoded chloride probes offer means of screening pharmacological agents, analysis of Cl− homeostasis and functions of Cl−-selective channels under different physiological and pathological conditions.
Collapse
|
13
|
Mosekilde E, Tass PA. Preface. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2008; 366:3437-3444. [PMID: 18632456 DOI: 10.1098/rsta.2008.0130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Affiliation(s)
- Erik Mosekilde
- Department of Physics, Technical University of Denmark, 2800 Kongens Lyngby, Denmark.
| | | |
Collapse
|