1
|
Kanatani JI, Fujiyoshi S, Isobe J, Kimata K, Watahiki M, Maenishi E, Izumiyama S, Amemura-Maekawa J, Maruyama F, Oishi K. Correlation between bacterial microbiome and Legionella species in water from public bath facilities by 16S rRNA gene amplicon sequencing. Microbiol Spectr 2024; 12:e0345923. [PMID: 38363136 PMCID: PMC10986325 DOI: 10.1128/spectrum.03459-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Accepted: 01/24/2024] [Indexed: 02/17/2024] Open
Abstract
Public bath facilities are a major source of Legionella infections in Japan. In this study, we performed 16S rRNA gene amplicon sequencing to characterize the bacterial community in bath and shower water from public bath facilities, along with chemical parameters, and investigated the effect of the bacterial microbiome on the presence of Legionella species. Although no significant difference in bacterial community richness was observed between bath and shower water samples, there was a remarkable difference in the bacterial community structure between them. Distance-based redundancy analysis revealed that several factors (free residual chlorine, pH, and conductivity) were correlated with the bacterial community in bath water. The most abundant bacterial genera in the samples were Pseudomonas (13.7%) in bath water and Phreatobacter (13.6%) in shower water, as indicated by the taxonomic composition, and the dominant bacteria differed between these environmental samples. Legionella pneumophila was the most frequently detected Legionella species, with additional 15 other Legionella species detected in water samples. In Legionella-positive water samples, several unassigned and uncultured bacteria were enriched together. In addition, the co-occurrence network showed that Legionella was strongly interconnected with two uncultured bacteria. Corynebacterium and Sphingomonas negatively correlated with Legionella species. The present study reveals the ecology of Legionella species, especially their interactions with other bacteria that are poorly understood to date. IMPORTANCE Public bath facilities are major sources of sporadic cases and outbreaks of Legionella infections. Recently, 16S rRNA gene amplicon sequencing has been used to analyze bacterial characteristics in various water samples from both artificial and natural environments, with a particular focus on Legionella bacterial species. However, the relationship between the bacterial community and Legionella species in the water from public bath facilities remains unclear. In terms of hygiene management, it is important to reduce the growth of Legionella species by disinfecting the water in public bath facilities. Our findings contribute to the establishment of appropriate hygiene management practices and provide a basis for understanding the potential health effects of using bath and shower water available in public bath facilities.
Collapse
Affiliation(s)
- Jun-ichi Kanatani
- Department of Bacteriology, Toyama Institute of Health, Imizu, Toyama, Japan
| | - So Fujiyoshi
- Section of Microbial Genomics and Ecology, Hiroshima University, Hiroshima, Japan
| | - Junko Isobe
- Department of Bacteriology, Toyama Institute of Health, Imizu, Toyama, Japan
| | - Keiko Kimata
- Department of Bacteriology, Toyama Institute of Health, Imizu, Toyama, Japan
| | - Masanori Watahiki
- Department of Bacteriology, Toyama Institute of Health, Imizu, Toyama, Japan
| | - Emi Maenishi
- Department of Bacteriology, Toyama Institute of Health, Imizu, Toyama, Japan
| | - Shinji Izumiyama
- Department of Parasitology, National Institute of Infectious Diseases, Toyama, Japan
| | - Junko Amemura-Maekawa
- Department of Bacteriology, National Institute of Infectious Diseases, Toyama, Japan
| | - Fumito Maruyama
- Section of Microbial Genomics and Ecology, Hiroshima University, Hiroshima, Japan
| | - Kazunori Oishi
- Department of Bacteriology, Toyama Institute of Health, Imizu, Toyama, Japan
| |
Collapse
|
2
|
Rutile-TiO2/PtO2 Glass Coatings Disinfects Aquatic Legionella pneumophila via Morphology Change and Endotoxin Degradation under LED Irradiation. Catalysts 2022. [DOI: 10.3390/catal12080856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Legionella pneumophila (L. pneumophila) is the causative agent of Legionnaires’ disease and Pontiac fever, collectively known as legionellosis. L. pneumophila infection occurs through inhalation of contaminated aerosols from water systems in workplaces and institutions. The development of disinfectants that can eliminate L. pneumophila in such water systems without evacuating people is needed to prevent the spread of L. pneumophila. Photocatalysts are attractive disinfectants that do not harm human health. In particular, the TiO2 photocatalyst kills L. pneumophila under various conditions, but its mode of action is unknown. Here, we confirmed the high performance of TiO2 photocatalyst containing PtO2 via the degradation of methylene blue (half-value period: 19.2 min) and bactericidal activity against Escherichia coli (half-value period: 15.1 min) in water. Using transmission electron microscopy, we demonstrate that the disinfection of L. pneumophila (half-value period: 6.7 min) by TiO2 photocatalyst in water is accompanied by remarkable cellular membrane and internal damage to L. pneumophila. Assays with limulus amebocyte lysate and silver staining showed the release of endotoxin from L. pneumophila due to membrane damage and photocatalytic degradation of this endotoxin. This is the first study to demonstrate the disinfection mechanisms of TiO2 photocatalyst, namely, via morphological changes and membrane damage of L. pneumophila. Our results suggest that TiO2 photocatalyst might be effective in controlling the spread of L. pneumophila.
Collapse
|
3
|
Girolamini L, Pascale MR, Mazzotta M, Spiteri S, Marino F, Salaris S, Grottola A, Orsini M, Cristino S. Combining Traditional and Molecular Techniques Supports the Discovery of a Novel Legionella Species During Environmental Surveillance in a Healthcare Facility. Front Microbiol 2022; 13:900936. [PMID: 35770167 PMCID: PMC9234573 DOI: 10.3389/fmicb.2022.900936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Accepted: 04/26/2022] [Indexed: 11/29/2022] Open
Abstract
Legionella surveillance plays a significant role not only to prevent the risk of infection but also to study the ecology of isolates, their characteristics, and how their prevalence changes in the environment. The difficulty in Legionella isolation, identification, and typing results in a low notification rate; therefore, human infection is still underestimated. In addition, during Legionella surveillance, the special attention given to Legionella pneumophila leads to an underestimation of the prevalence and risk of infection for other species. This study describes the workflow performed during environmental Legionella surveillance that resulted in the isolation of two strains, named 8cVS16 and 9fVS26, associated with the genus Legionella. Traditional and novel approaches such as standard culture technique, MALDI-TOF MS, gene sequencing, and whole-genome sequencing (WGS) analysis were combined to demonstrate that isolates belong to a novel species. The strain characteristics, the differences between macrophage infectivity potential (mip), RNA polymerase β subunit (rpoB), and reference gene sequences, the average nucleotide identity (ANI) of 90.4%, and the DNA–DNA digital hybridization (dDDH) analysis of 43% demonstrate that these isolates belong to a new Legionella species. The finding suggests that, during the culture technique, special attention should be paid to the characteristics of the isolates that are less associated with the Legionella genus in order to investigate the differences found using more sensitive methods. The characterization of the two newly discovered isolates based on morphological, biochemical, and microscopic characteristics is currently underway and will be described in another future study.
Collapse
Affiliation(s)
- Luna Girolamini
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
- European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Legionella Infections (ESGLI), Basel, Switzerland
| | - Maria Rosaria Pascale
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
- Department of Civil, Chemical, Environmental, and Materials Engineering, University of Bologna, Bologna, Italy
| | - Marta Mazzotta
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
| | - Simona Spiteri
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
- Department of Specialty, Diagnostic and Experimental Medicine, University of Bologna, Bologna, Italy
| | - Federica Marino
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
| | - Silvano Salaris
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
| | - Antonella Grottola
- European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Legionella Infections (ESGLI), Basel, Switzerland
- Regional Reference Laboratory for Clinical Diagnosis of Legionellosis, Molecular Microbiology and Virology Unit, University Hospital-Policlinico Modena, Modena, Italy
| | - Massimiliano Orsini
- Laboratory of Microbial Ecology and Genomics of Microorganisms, Istituto Zooprofilattico Sperimentale delle Venezie, Legnaro, Italy
| | - Sandra Cristino
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
- European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Legionella Infections (ESGLI), Basel, Switzerland
- *Correspondence: Sandra Cristino
| |
Collapse
|
4
|
Girolamini L, Salaris S, Pascale MR, Mazzotta M, Cristino S. Dynamics of Legionella Community Interactions in Response to Temperature and Disinfection Treatment: 7 Years of Investigation. MICROBIAL ECOLOGY 2022; 83:353-362. [PMID: 34091718 PMCID: PMC8891097 DOI: 10.1007/s00248-021-01778-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 05/17/2021] [Indexed: 05/12/2023]
Abstract
In man-made water distribution systems, Legionella community interactions remain unknown, due to their ability to change from sessile to planktonic states or live in viable but non-culturable forms, in response to anthropic and environmental stress. During 7 years of hospital Legionella surveillance, in 191 hot water positive samples, the interactions among the Legionella species, temperature, and disinfection treatment were evaluated. Legionella was isolated following ISO 11731:2017, and identification was performed by mip gene sequencing and sequence-based typing (SBT) for L. anisa or L. rubrilucens and L. pneumophila, respectively. The species with the higher frequency of isolation was L. pneumophila serogroup 1 (78.53%; 4865.36 ± 25,479.11 cfu/L), followed by L. anisa (54.45%; 558.79 ± 2637.41 cfu/L) and L. rubrilucens (21.99%; 307.73 ± 1574.95 cfu/L), which were sometimes present together. Spearman's rho correlation test was conducted among the species with respect to temperature and disinfectant (H2O2/Ag+). The results showed a generally positive interaction among these species sharing the same environment, except for competition between L. anisa and L. rubrilucens. High temperature (48.83 ± 2.59 °C) and disinfection treatment (11.58 ± 4.99 mg/L) affected the presence of these species. An exception was observed with L. anisa, which showed disinfection treatment resistance. For the purposes of environmental surveillance, it is fundamental to better understand the interactions and dynamic of the Legionella community in man-made water systems in order to choose the proper physical or chemical treatments. The simultaneous presence of different Legionella species could result in an increased resistance to high temperature and disinfectant treatment, leading to changes in contamination level and species diversity.
Collapse
Affiliation(s)
- Luna Girolamini
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, via San Giacomo 12, 40126 Bologna, BO Italy
| | - Silvano Salaris
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, via San Giacomo 12, 40126 Bologna, BO Italy
| | - Maria Rosaria Pascale
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, via San Giacomo 12, 40126 Bologna, BO Italy
| | - Marta Mazzotta
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, via San Giacomo 12, 40126 Bologna, BO Italy
| | - Sandra Cristino
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, via San Giacomo 12, 40126 Bologna, BO Italy
| |
Collapse
|
5
|
Pascale MR, Salaris S, Mazzotta M, Girolamini L, Fregni Serpini G, Manni L, Grottola A, Cristino S. New Insight regarding Legionella Non- Pneumophila Species Identification: Comparison between the Traditional mip Gene Classification Scheme and a Newly Proposed Scheme Targeting the rpoB Gene. Microbiol Spectr 2021; 9:e0116121. [PMID: 34908503 PMCID: PMC8672888 DOI: 10.1128/spectrum.01161-21] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Accepted: 11/11/2021] [Indexed: 11/23/2022] Open
Abstract
The identification of Legionella non-pneumophila species (non-Lp) in clinical and environmental samples is based on the mip gene, although several studies suggest its limitations and the need to expand the classification scheme to include other genes. In this study, the development of a new classification scheme targeting the rpoB gene is proposed to obtain a more reliable identification of 135 Legionella environmental isolates. All isolates were sequenced for the mip and rpoB genes, and the results were compared to study the discriminatory power of the proposed rpoB scheme. Complete concordance between the mip and rpoB results based on genomic percent identity was found for 121/135 (89.6%) isolates; in contrast, discordance was found for 14/135 (10.4%) isolates. Additionally, due to the lack of reference values for the rpoB gene, inter- and intraspecies variation intervals were calculated based on a pairwise identity matrix that was built using the entire rpoB gene (∼4,107 bp) and a partial region (329 bp) to better evaluate the genomic identity obtained. The interspecies variation interval found here (4.9% to 26.7%) was then proposed as a useful sequence-based classification scheme for the identification of unknown non-Lp isolates. The results suggest that using both the mip and rpoB genes makes it possible to correctly discriminate between several species, allowing possible new species to be identified, as confirmed by preliminary whole-genome sequencing analyses performed on our isolates. Therefore, starting from a valid and reliable identification approach, the simultaneous use of mip and rpoB associated with other genes, as it occurs with the sequence-based typing (SBT) scheme developed for Legionella pneumophila, could support the development of multilocus sequence typing to improve the knowledge and discovery of Legionella species subtypes. IMPORTANCELegionella spp. are a widely spread bacteria that cause a fatal form of pneumonia. While traditional laboratory techniques have provided valuable systems for Legionella pneumophila identification, the amplification of the mip gene has been recognized as the only useful tool for Legionella non-pneumophila species identification both in clinical and environmental samples. Several studies focused on the mip gene classification scheme showed its limitations and the need to improve the classification scheme, including other genes. Our study provides significant advantages on Legionella identification, providing a reproducible new rpoB gene classification scheme that seems to be more accurate than mip gene sequencing, bringing out greater genetic variation on Legionella species. In addition, the combined use of both the mip and rpoB genes allowed us to identify presumed new Legionella species, improving epidemiological investigations and acquiring new understanding on Legionella fields.
Collapse
Affiliation(s)
- Maria Rosaria Pascale
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
| | - Silvano Salaris
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
| | - Marta Mazzotta
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
| | - Luna Girolamini
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
| | - Giulia Fregni Serpini
- Regional Reference Laboratory for Clinical Diagnosis of Legionellosis, Molecular Microbiology and Virology Unit, University Hospital-Policlinico Modena, Modena, Italy
| | - Laura Manni
- Regional Reference Laboratory for Clinical Diagnosis of Legionellosis, Molecular Microbiology and Virology Unit, University Hospital-Policlinico Modena, Modena, Italy
| | - Antonella Grottola
- Regional Reference Laboratory for Clinical Diagnosis of Legionellosis, Molecular Microbiology and Virology Unit, University Hospital-Policlinico Modena, Modena, Italy
| | - Sandra Cristino
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
| |
Collapse
|
6
|
Brigmon RL, Turick CE, Knox AS, Burckhalter CE. The Impact of Storms on Legionella pneumophila in Cooling Tower Water, Implications for Human Health. Front Microbiol 2020; 11:543589. [PMID: 33362725 PMCID: PMC7758282 DOI: 10.3389/fmicb.2020.543589] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Accepted: 11/02/2020] [Indexed: 12/03/2022] Open
Abstract
At the U.S. Department of Energy’s Savannah River Site (SRS) in Aiken, SC, cooling tower water is routinely monitored for Legionella pneumophila concentrations using a direct fluorescent antibody (DFA) technique. Historically, 25–30 operating SRS cooling towers have varying concentrations of Legionella in all seasons of the year, with patterns that are unpredictable. Legionellosis, or Legionnaires’ disease (LD), is a pneumonia caused by Legionella bacteria that thrive both in man-made water distribution systems and natural surface waters including lakes, streams, and wet soil. Legionnaires’ disease is typically contracted by inhaling L. pneumophila, most often in aerosolized mists that contain the bacteria. At the SRS, L. pneumophila is typically found in cooling towers ranging from non-detectable up to 108 cells/L in cooling tower water systems. Extreme weather conditions contributed to elevations in L. pneumophila to 107–108 cells/L in SRS cooling tower water systems in July–August 2017. L. pneumophila concentrations in Cooling Tower 785-A/2A located in SRS A-Area, stayed in the 108 cells/L range despite biocide addition. During this time, other SRS cooling towers did not demonstrate this L. pneumophila increase. No significant difference was observed in the mean L. pneumophila mean concentrations for the towers (p < 0.05). There was a significant variance observed in the 285-2A/A Tower L. pneumophila results (p < 0.05). Looking to see if we could find “effects” led to model development by analyzing 13 months of water chemistry and microbial data for the main factors influencing the L. pneumophila concentrations in five cooling towers for this year. It indicated chlorine and dissolved oxygen had a significant impact (p < 0.0002) on cooling tower 785A/2A. Thus, while the variation in the log count data for the A-area tower is statistically greater than that of the other four towers, the average of the log count data for the A-Area tower was in line with that of the other towers. It was also observed that the location of 785A/2A and basin resulted in more debris entering the system during storm events. Our results suggest that future analyses should evaluate the impact of environmental conditions and cooling tower design on L. pneumophila water concentrations and human health.
Collapse
Affiliation(s)
- Robin L Brigmon
- Savannah River National Laboratory, Environmental Science and Biotechnology Group, Aiken, SC, United States
| | - Charles E Turick
- Savannah River National Laboratory, Environmental Science and Biotechnology Group, Aiken, SC, United States
| | - Anna S Knox
- Savannah River National Laboratory, Environmental Science and Biotechnology Group, Aiken, SC, United States
| | - Courtney E Burckhalter
- Savannah River National Laboratory, Environmental Science and Biotechnology Group, Aiken, SC, United States
| |
Collapse
|
7
|
How Molecular Typing Can Support Legionella Environmental Surveillance in Hot Water Distribution Systems: A Hospital Experience. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17228662. [PMID: 33233464 PMCID: PMC7700474 DOI: 10.3390/ijerph17228662] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 10/27/2020] [Accepted: 11/18/2020] [Indexed: 12/12/2022]
Abstract
In this study, we aimed to associate the molecular typing of Legionella isolates with a culture technique during routine Legionella hospital environmental surveillance in hot water distribution systems (HWDSs) to develop a risk map able to be used to prevent nosocomial infections and formulate appropriate preventive measures. Hot water samples were cultured according to ISO 11731:2017. The isolates were serotyped using an agglutination test and genotyped by sequence-based typing (SBT) for Legionella pneumophila or macrophage infectivity potentiator (mip) gene sequencing for non-pneumophila Legionella species. The isolates' relationship was phylogenetically analyzed. The Legionella distribution and level of contamination were studied in relation to temperature and disinfectant residues. The culture technique detected 62.21% of Legionella positive samples, characterized by L. pneumophila serogroup 1, Legionella non-pneumophila, or both simultaneously. The SBT assigned two sequence types (STs): ST1, the most prevalent in Italy, and ST104, which had never been isolated before. The mip gene sequencing detected L. anisa and L. rubrilucens. The phylogenetic analysis showed distinct clusters for each species. The distribution of Legionella isolates showed significant differences between buildings, with a negative correlation between the measured level of contamination, disinfectant, and temperature. The Legionella molecular approach introduced in HWDSs environmental surveillance permits (i) a risk map to be outlined that can help formulate appropriate disinfection strategies and (ii) rapid epidemiological investigations to quickly identify the source of Legionella infections.
Collapse
|
8
|
Antimicrobial Effect of Visible Light-Photoinactivation of Legionella rubrilucens by Irradiation at 450, 470, and 620 nm. Antibiotics (Basel) 2019; 8:antibiotics8040187. [PMID: 31618994 PMCID: PMC6963517 DOI: 10.3390/antibiotics8040187] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2019] [Revised: 10/11/2019] [Accepted: 10/13/2019] [Indexed: 01/12/2023] Open
Abstract
Despite the high number of legionella infections, there are currently no convincing preventive measures. Photoinactivation with visible light is a promising new approach and the photoinactivation sensitivity properties of planktonic Legionella rubrilucens to 450, 470, and 620 nm irradiation were thus investigated and compared to existing 405 nm inactivation data for obtaining information on responsible endogenous photosensitizers. Legionella were streaked on agar plates and irradiated with different doses by light emitting diodes (LEDs) of different visible wavelengths. When irradiating bacterial samples with blue light of 450 nm, a 5-log reduction could be achieved by applying a dose of 300 J cm−2, whereas at 470 nm, a comparable reduction required about 500 J cm−2. For red irradiation at 620 nm, no inactivation could be observed, even at 500 J cm−2. The declining photoinactivation sensitivity with an increasing wavelength is consistent with the assumption of porphyrins and flavins being among the relevant photosensitizers. These results were obtained for L. rubrilucens, but there is reason to believe that its inactivation behavior is similar to that of pathogenic legionella species. Therefore, this photoinactivation might lead to new future concepts for legionella reduction and prevention in technical applications or even on or inside the human body.
Collapse
|
9
|
|
10
|
Legionella pneumophila and Other Legionella Species Isolated from Legionellosis Patients in Japan between 2008 and 2016. Appl Environ Microbiol 2018; 84:AEM.00721-18. [PMID: 29980559 DOI: 10.1128/aem.00721-18] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Accepted: 06/27/2018] [Indexed: 12/13/2022] Open
Abstract
The Legionella Reference Center in Japan collected 427 Legionella clinical isolates between 2008 and 2016, including 7 representative isolates from corresponding outbreaks. The collection included 419 Legionella pneumophila isolates, of which 372 belonged to serogroup 1 (SG1) (87%) and the others belonged to SG2 to SG15 except for SG7 and SG11, and 8 isolates of other Legionella species (Legionella bozemanae, Legionella dumoffii, Legionella feeleii, Legionella longbeachae, Legionella londiniensis, and Legionella rubrilucens). L. pneumophila isolates were genotyped by sequence-based typing (SBT) and represented 187 sequence types (STs), of which 126 occurred in a single isolate (index of discrimination of 0.984). These STs were analyzed using minimum spanning tree analysis, resulting in the formation of 18 groups. The pattern of overall ST distribution among L. pneumophila isolates was diverse. In particular, some STs were frequently isolated and were suggested to be related to the infection sources. The major STs were ST23 (35 isolates), ST120 (20 isolates), and ST138 (16 isolates). ST23 was the most prevalent and most causative ST for outbreaks in Japan and Europe. ST138 has been observed only in Japan, where it has caused small-scale outbreaks; 81% of those strains (13 isolates) were suspected or confirmed to infect humans through bath water sources. On the other hand, 11 ST23 strains (31%) and 5 ST120 strains (25%) were suspected or confirmed to infect humans through bath water. These findings suggest that some ST strains frequently cause legionellosis in Japan and are found under different environmental conditions.IMPORTANCELegionella pneumophila serogroup 1 (SG1) is the most frequent cause of legionellosis. Our previous genetic analysis indicated that SG1 environmental isolates represented 8 major clonal complexes, consisting of 3 B groups, 2 C groups, and 3 S groups, which included major environmental isolates derived from bath water, cooling towers, and soil and puddles, respectively. Here, we surveyed clinical isolates collected from patients with legionellosis in Japan between 2008 and 2016. Most strains belonging to the B group were isolated from patients for whom bath water was the suspected or confirmed source of infection. Among the isolates derived from patients whose suspected infection source was soil or dust, most belonged to the S1 group and none belonged to the B or C groups. Additionally, the U group was discovered as a new group, which mainly included clinical isolates with unknown infection sources.
Collapse
|
11
|
Leoni E, Catalani F, Marini S, Dallolio L. Legionellosis Associated with Recreational Waters: A Systematic Review of Cases and Outbreaks in Swimming Pools, Spa Pools, and Similar Environments. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2018; 15:E1612. [PMID: 30061526 PMCID: PMC6121464 DOI: 10.3390/ijerph15081612] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Revised: 07/20/2018] [Accepted: 07/25/2018] [Indexed: 12/24/2022]
Abstract
Legionella spp. is widespread in many natural and artificial water systems, such as hot water distribution networks, cooling towers, and spas. A particular risk factor has been identified in the use of whirlpools and hot tubs in spa facilities and public baths. However, there has been no systematic synthesis of the published literature reporting legionellosis cases or outbreaks related to swimming/spa pools or similar environments used for recreational purposes (hot springs, hot tubs, whirlpools, natural spas). This study presents the results of a systematic review of the literature on cases and outbreaks associated with these environments. Data were extracted from 47 articles, including 42 events (17 sporadic cases and 25 outbreaks) and 1079 cases, 57.5% of which were diagnosed as Pontiac fever, without any deaths, and 42.5% were of Legionnaires' disease, with a fatality rate of 6.3%. The results are presented in relation to the distribution of Legionella species involved in the events, clinical manifestations and diagnosis, predisposing conditions in the patients, favourable environmental factors, and quality of the epidemiological investigation, as well as in relation to the different types of recreational water sources involved. Based on the epidemiological and microbiological criteria, the strength of evidence linking a case/outbreak of legionellosis with a recreational water system was classified as strong, probable, and possible; in more than half of the events the resulting association was strong.
Collapse
Affiliation(s)
- Erica Leoni
- Unit of Hygiene, Public Health and Medical Statistics, Department of Biomedical and Neuromotor Sciences, University of Bologna, via S. Giacomo 12, 40126 Bologna, Italy.
| | - Federica Catalani
- School of Hygiene and Preventive Medicine, Department of Biomedical and Neuromotor Sciences, University of Bologna, via S. Giacomo 12, 40126 Bologna, Italy.
| | - Sofia Marini
- Department of Life Quality Studies, University of Bologna, Campus of Rimini; Corso d'Augusto 237, 47921 Rimini, Italy.
| | - Laura Dallolio
- Unit of Hygiene, Public Health and Medical Statistics, Department of Biomedical and Neuromotor Sciences, University of Bologna, via S. Giacomo 12, 40126 Bologna, Italy.
| |
Collapse
|
12
|
Orkis LT, Harrison LH, Mertz KJ, Brooks MM, Bibby KJ, Stout JE. Environmental sources of community-acquired legionnaires' disease: A review. Int J Hyg Environ Health 2018; 221:764-774. [PMID: 29729999 DOI: 10.1016/j.ijheh.2018.04.013] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Revised: 04/27/2018] [Accepted: 04/27/2018] [Indexed: 11/25/2022]
Abstract
BACKGROUND Most Legionnaires' disease in the US and abroad is community-acquired and believed to be sporadic, or non-outbreak associated. Most patients are exposed to numerous water sources, thus making it difficult to focus environmental investigations. Identifying known sources of sporadic community-acquired Legionnaires' disease will inform future sporadic Legionnaires' disease investigations as well as highlight directions for research. The objective is to summarize and rank sporadic Legionnaires' disease sources based on the level of linkage between the environmental source and cases. METHODS A PubMed search was conducted using the search terms legion* and (origins or source or transmission) and (sporadic or community-acquired). Studies of nosocomial and/or outbreak-associated disease were excluded from this review. Definite, probable, possible and suspect ranks were assigned to sources based on evidence of linkage to sporadic Legionnaires' disease. RESULTS The search yielded 196 articles and 47 articles were included in the final review after application of exclusion criteria. A total of 28 sources were identified. Of these, eight were assigned definite rank including residential potable water and car air-conditioner water leakage. Probable rank was assigned to five sources including solar-heated potable water and soil. Possible rank was assigned to nine sources including residential potable water and cooling towers. Suspect rank was assigned to 20 sources including large building water systems and cooling towers. CONCLUSION Residential potable water, large building water systems and car travel appear to contribute to a substantial proportion of sporadic Legionnaires' disease. Cooling towers are also a potentially significant source; however, definitive linkage to sporadic cases proves difficult. The sources of sporadic Legionnaires' disease cannot be definitively identified for most cases.
Collapse
Affiliation(s)
- Lauren T Orkis
- Department of Epidemiology, University of Pittsburgh Graduate School of Public Health, 130 DeSoto Street, Pittsburgh, PA, 15261, USA; Bureau of Assessment, Statistics, and Epidemiology, Allegheny County Health Department, 542 Fourth Ave. Pittsburgh, PA, 15219, USA.
| | - Lee H Harrison
- Department of Epidemiology, University of Pittsburgh Graduate School of Public Health, 130 DeSoto Street, Pittsburgh, PA, 15261, USA; Infectious Diseases Epidemiology Research Unit, University of Pittsburgh Division of Infectious Diseases and Department of Epidemiology, 3550 Terrace Street, Pittsburgh, PA, 15261, USA
| | - Kristen J Mertz
- Bureau of Assessment, Statistics, and Epidemiology, Allegheny County Health Department, 542 Fourth Ave. Pittsburgh, PA, 15219, USA
| | - Maria M Brooks
- Department of Epidemiology, University of Pittsburgh Graduate School of Public Health, 130 DeSoto Street, Pittsburgh, PA, 15261, USA
| | - Kyle J Bibby
- Department of Civil, and Environmental Engineering, University of Pittsburgh Swanson School of Engineering, 3700 O'Hara Street, Pittsburgh, PA, 15261, USA
| | - Janet E Stout
- Department of Civil, and Environmental Engineering, University of Pittsburgh Swanson School of Engineering, 3700 O'Hara Street, Pittsburgh, PA, 15261, USA; Special Pathogens Laboratory, 1401 Forbes Ave #401, Pittsburgh, PA, 15219, USA
| |
Collapse
|
13
|
Schmid J, Hoenes K, Rath M, Vatter P, Spellerberg B, Hessling M. Photoinactivation of Legionella Rubrilucens by Visible Light. Eur J Microbiol Immunol (Bp) 2017; 7:146-149. [PMID: 28690882 PMCID: PMC5495087 DOI: 10.1556/1886.2017.00006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Accepted: 03/28/2017] [Indexed: 12/02/2022] Open
Abstract
In this study, the photoinactivation of Legionella by visible light is investigated. The success of this approach would offer new prospects for technical water disinfection and maybe even for therapeutic measures in cases of Legionella infections. Therefore, Legionella rubrilucens was dispensed on buffered charcoal yeast extract medium agar plates and illuminated with different doses of violet light generated by 405 nm light-emitting diodes (LEDs). A strong photoinactivation effect was observed. A dose of 125 J/ cm2 reduced the bacterial concentration by more than 5 orders of magnitude compared to Legionella on unirradiated agar plates. The necessary dose for a one log-level reduction was about 24 J/cm2. These results were obtained for extracellular L. rubrilucens, but other Legionella species may exhibit a similar behavior.
Collapse
Affiliation(s)
- J Schmid
- Ulm University of Applied Sciences, Albert-Einstein-Allee 55, D 89081 Ulm, Germany
| | - K Hoenes
- Ulm University of Applied Sciences, Albert-Einstein-Allee 55, D 89081 Ulm, Germany
| | - M Rath
- Ulm University of Applied Sciences, Albert-Einstein-Allee 55, D 89081 Ulm, Germany
| | - P Vatter
- Ulm University of Applied Sciences, Albert-Einstein-Allee 55, D 89081 Ulm, Germany
| | - B Spellerberg
- Institute of Medical Microbiology and Hygiene, University of Ulm, Ulm, Germany
| | - M Hessling
- Ulm University of Applied Sciences, Albert-Einstein-Allee 55, D 89081 Ulm, Germany
| |
Collapse
|
14
|
Schmid J, Hoenes K, Rath M, Vatter P, Hessling M. UV-C inactivation of Legionella rubrilucens. GMS HYGIENE AND INFECTION CONTROL 2017; 12:Doc06. [PMID: 28451517 PMCID: PMC5388836 DOI: 10.3205/dgkh000291] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Background: Despite the great health significance of Legionella, there is only little information on their UV sensitivity. Besides Legionella pneumophila only L. longbeachae has been investigated so far. Methods: In this study L. rubrilucens has been spread on buffered charcoal yeast extract agar and irradiated with the 254 nm UV-C emission of a mercury vapor lamp. The disinfection success is measured by colony counting after incubation and comparison of the number of colonies on irradiated and unirradiated reference agar plates. Results: The average log-reduction dose is 1.08 mJ/cm2 for free L. rubrilucens, which is at the lower end of the so far published Legionella log-reduction values, but all three Legionella species show similar UV-C sensitivities. Conclusion: The log-reduction dose of legionellae in amoebae has not been investigated, but with the observed high UV-C sensitivity for free Legionella, the idea of a future point-of-use disinfection by small UV-C LEDs in water-taps or shower heads appears to be realistic, even if legionellae are more resistant in amoebae.
Collapse
Affiliation(s)
| | | | - Monika Rath
- Ulm University of Applied Sciences, Ulm, Germany
| | - Petra Vatter
- Ulm University of Applied Sciences, Ulm, Germany
| | | |
Collapse
|
15
|
Sánchez-Busó L, Guiral S, Crespi S, Moya V, Camaró ML, Olmos MP, Adrián F, Morera V, González-Morán F, Vanaclocha H, González-Candelas F. Genomic Investigation of a Legionellosis Outbreak in a Persistently Colonized Hotel. Front Microbiol 2016; 6:1556. [PMID: 26834713 PMCID: PMC4720873 DOI: 10.3389/fmicb.2015.01556] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2015] [Accepted: 12/22/2015] [Indexed: 12/22/2022] Open
Abstract
Objectives: A long-lasting legionellosis outbreak was reported between November 2011 and July 2012 in a hotel in Calpe (Spain) affecting 44 patients including six deaths. Intensive epidemiological and microbiological investigations were performed in order to detect the reservoirs. Methods: Clinical and environmental samples were tested for the presence and genetic characterization of Legionella pneumophila. Six of the isolates were subjected to whole-genome sequencing. Results: Sequencing of 14 clinical and 260 environmental samples revealed sequence type (ST) 23 as the main responsible strain for the infections. This ST was found in the spa pool, from where it spread to other hotel public spaces, explaining the ST23 clinical cases, including guests who had not visited the spa. Uncultured clinical specimens showed profiles compatible with ST23, ST578, and mixed patterns. Profiles compatible with ST578 were obtained by direct sequencing from biofilm samples collected from the domestic water system, which provided evidence for the source of infection for non ST23 patients. Whole genome data from five ST23 strains and the identification of different STs and Legionella species showed that different hotel premises were likely colonized since the hotel opening thus explaining how different patients had been infected by distinct STs. Conclusions: Both epidemiological and molecular data are essential in the investigation of legionellosis outbreaks. Whole-genome sequencing data revealed significant intra-ST variability and allowed to make further inference on the short-term evolution of a local colonization of L. pneumophila.
Collapse
Affiliation(s)
- Leonor Sánchez-Busó
- Unidad Mixta "Infección y Salud Pública" Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana-Salud Pública, Universitat de ValènciaValencia, Spain; Centros de Investigación Biomédica en Red Epidemiología y Salud PúblicaValencia, Spain
| | - Silvia Guiral
- Unidad Mixta "Infección y Salud Pública" Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana-Salud Pública, Universitat de ValènciaValencia, Spain; Dirección General de Salud Pública, Subdirección de Epidemiología y Vigilancia de la SaludValencia, Spain
| | - Sebastián Crespi
- Biolinea IntPalma de Mallorca, Spain; Policlínica MiramarPalma de Mallorca, Spain
| | | | - María L Camaró
- Dirección General de Salud Pública, Laboratorio de Salud Pública Valencia, Spain
| | - María P Olmos
- Dirección General de Salud Pública, Laboratorio de Salud Pública Valencia, Spain
| | | | | | - Francisco González-Morán
- Unidad Mixta "Infección y Salud Pública" Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana-Salud Pública, Universitat de ValènciaValencia, Spain; Dirección General de Salud Pública, Subdirección de Epidemiología y Vigilancia de la SaludValencia, Spain
| | - Hermelinda Vanaclocha
- Unidad Mixta "Infección y Salud Pública" Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana-Salud Pública, Universitat de ValènciaValencia, Spain; Dirección General de Salud Pública, Subdirección de Epidemiología y Vigilancia de la SaludValencia, Spain
| | - Fernando González-Candelas
- Unidad Mixta "Infección y Salud Pública" Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana-Salud Pública, Universitat de ValènciaValencia, Spain; Centros de Investigación Biomédica en Red Epidemiología y Salud PúblicaValencia, Spain
| |
Collapse
|
16
|
van Heijnsbergen E, Schalk JAC, Euser SM, Brandsema PS, den Boer JW, de Roda Husman AM. Confirmed and Potential Sources of Legionella Reviewed. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2015; 49:4797-815. [PMID: 25774976 DOI: 10.1021/acs.est.5b00142] [Citation(s) in RCA: 81] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Legionella bacteria are ubiquitous in natural matrices and man-made systems. However, it is not always clear if these reservoirs can act as source of infection resulting in cases of Legionnaires' disease. This review provides an overview of reservoirs of Legionella reported in the literature, other than drinking water distribution systems. Levels of evidence were developed to discriminate between potential and confirmed sources of Legionella. A total of 17 systems and matrices could be classified as confirmed sources of Legionella. Many other man-made systems or natural matrices were not classified as a confirmed source, since either no patients were linked to these reservoirs or the supporting evidence was weak. However, these systems or matrices could play an important role in the transmission of infectious Legionella bacteria; they might not yet be considered in source investigations, resulting in an underestimation of their importance. To optimize source investigations it is important to have knowledge about all the (potential) sources of Legionella. Further research is needed to unravel what the contribution is of each confirmed source, and possibly also potential sources, to the LD disease burden.
Collapse
Affiliation(s)
- Eri van Heijnsbergen
- †National Institute for Public Health and the Environment, A. van Leeuwenhoeklaan 9, 3721 MA Bilthoven, The Netherlands
| | - Johanna A C Schalk
- †National Institute for Public Health and the Environment, A. van Leeuwenhoeklaan 9, 3721 MA Bilthoven, The Netherlands
| | - Sjoerd M Euser
- ‡Regional Public Health Laboratory Kennemerland, Haarlem, Boerhaavelaan 26, 2035 RC Haarlem, The Netherlands
| | - Petra S Brandsema
- †National Institute for Public Health and the Environment, A. van Leeuwenhoeklaan 9, 3721 MA Bilthoven, The Netherlands
| | - Jeroen W den Boer
- ‡Regional Public Health Laboratory Kennemerland, Haarlem, Boerhaavelaan 26, 2035 RC Haarlem, The Netherlands
| | - Ana Maria de Roda Husman
- †National Institute for Public Health and the Environment, A. van Leeuwenhoeklaan 9, 3721 MA Bilthoven, The Netherlands
- §Institute for Risk Assessment Sciences, Utrecht University, Yalelaan 2, 3584 CM Utrecht, The Netherlands
| |
Collapse
|
17
|
Mercante JW, Winchell JM. Current and emerging Legionella diagnostics for laboratory and outbreak investigations. Clin Microbiol Rev 2015; 28:95-133. [PMID: 25567224 PMCID: PMC4284297 DOI: 10.1128/cmr.00029-14] [Citation(s) in RCA: 217] [Impact Index Per Article: 24.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Legionnaires' disease (LD) is an often severe and potentially fatal form of bacterial pneumonia caused by an extensive list of Legionella species. These ubiquitous freshwater and soil inhabitants cause human respiratory disease when amplified in man-made water or cooling systems and their aerosols expose a susceptible population. Treatment of sporadic cases and rapid control of LD outbreaks benefit from swift diagnosis in concert with discriminatory bacterial typing for immediate epidemiological responses. Traditional culture and serology were instrumental in describing disease incidence early in its history; currently, diagnosis of LD relies almost solely on the urinary antigen test, which captures only the dominant species and serogroup, Legionella pneumophila serogroup 1 (Lp1). This has created a diagnostic "blind spot" for LD caused by non-Lp1 strains. This review focuses on historic, current, and emerging technologies that hold promise for increasing LD diagnostic efficiency and detection rates as part of a coherent testing regimen. The importance of cooperation between epidemiologists and laboratorians for a rapid outbreak response is also illustrated in field investigations conducted by the CDC with state and local authorities. Finally, challenges facing health care professionals, building managers, and the public health community in combating LD are highlighted, and potential solutions are discussed.
Collapse
Affiliation(s)
- Jeffrey W Mercante
- Pneumonia Response and Surveillance Laboratory, Respiratory Diseases Branch, U.S. Centers for Disease Control and Prevention, Atlanta, Georgia, USA
| | - Jonas M Winchell
- Pneumonia Response and Surveillance Laboratory, Respiratory Diseases Branch, U.S. Centers for Disease Control and Prevention, Atlanta, Georgia, USA
| |
Collapse
|
18
|
Wewalka G, Schmid D, Harrison T, Uldum S, Lück C. Dual infections with different Legionella strains. Clin Microbiol Infect 2014; 20:O13-9. [DOI: 10.1111/1469-0691.12311] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2013] [Revised: 06/03/2013] [Accepted: 06/19/2013] [Indexed: 11/28/2022]
|
19
|
Coscollá M, Fernández C, Colomina J, Sánchez-Busó L, González-Candelas F. Mixed infection by Legionella pneumophila in outbreak patients. Int J Med Microbiol 2013; 304:307-13. [PMID: 24309206 DOI: 10.1016/j.ijmm.2013.11.002] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2013] [Revised: 09/26/2013] [Accepted: 11/09/2013] [Indexed: 12/20/2022] Open
Abstract
During the molecular epidemiological study of a legionellosis outbreak, we obtained sequence based typing (SBT) profiles from uncultured respiratory samples of 15 affected patients. We detected several distinct allelic profiles some of which were a mixture of alleles present in the more common profiles. Chromatograms from the sequences of one patient with mixed profile showed polymorphisms in several positions, which could result from the simultaneous presence of different Legionella variants in the sample. In order to test this possibility, we cloned PCR amplification products from six loci for two patients with a mixed profile and a patient with a pure profile. After obtaining around 20 sequences for each locus of three patients, we detected several variants in two of them and two variants in the third one. In summary, the three analyzed patients showed evidence of more than one Legionella variant during the acute infection. These results indicate that probably some patients were infected by more than one strain, which could be due to co-infection from the same environmental source or, alternatively, to independent infections in a very short period of time. Although our data cannot discriminate between these hypotheses, these results suggest that Legionella infection patterns can be more complex than previously assumed. None of the environmental samples analyzed during this outbreak was even similar to any of the clinical ones.
Collapse
Affiliation(s)
- Mireia Coscollá
- Unidad Mixta Genómica y Salud, FISABIO-Salud Pública, Universidad de Valencia, Instituto Cavanilles de Biodiversidad y Biología Evolutiva, Valencia, Spain; CIBER en Epidemiología y Salud Pública (CIBERESP), Spain; Tuberculosis Research Unit, Swiss Tropical and Public Health Institute, Basel, Switzerland
| | - Carmen Fernández
- Centro de Salud Pública de Alzira, Conselleria de Sanitat, Valencia, Spain
| | - Javier Colomina
- Servicio de Microbiología, Hospital Universitario de La Ribera, Alzira, Valencia, Spain
| | - Leonor Sánchez-Busó
- Unidad Mixta Genómica y Salud, FISABIO-Salud Pública, Universidad de Valencia, Instituto Cavanilles de Biodiversidad y Biología Evolutiva, Valencia, Spain; CIBER en Epidemiología y Salud Pública (CIBERESP), Spain
| | - Fernando González-Candelas
- Unidad Mixta Genómica y Salud, FISABIO-Salud Pública, Universidad de Valencia, Instituto Cavanilles de Biodiversidad y Biología Evolutiva, Valencia, Spain; CIBER en Epidemiología y Salud Pública (CIBERESP), Spain.
| |
Collapse
|
20
|
Abstract
In this chapter we describe the methods currently used for subgrouping Legionella pneumophila and other non-pneumophila species. In the first part we describe monoclonal antibody (mAb) subgrouping, either by indirect immunofluorescence or indirect ELISA methods. These monoclonal antibodies are not commercially available but can be obtained for noncommercial purposes from one of the authors. Further, we describe pulsed-field gel electrophoresis (PFGE), amplified fragment length polymorphism (AFLP) and sequence-based typing (SBT) as well standardized and reproducible methods for genotyping. The SBT schema is currently available for L. pneumophila whereas PFGE and AFLP can be used for all Legionella species. For certain applications it might be useful to use spoligotyping to distinguish strains belonging to the same sequence type (ST).
Collapse
Affiliation(s)
- Christian Lück
- Institute for Medical Microbiology and Hygiene, University of Technology, Dresden, Germany.
| | | | | | | | | |
Collapse
|