1
|
Roth BJ. The magnetocardiogram. BIOPHYSICS REVIEWS 2024; 5:021305. [PMID: 38827563 PMCID: PMC11139488 DOI: 10.1063/5.0201950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Accepted: 05/06/2024] [Indexed: 06/04/2024]
Abstract
The magnetic field produced by the heart's electrical activity is called the magnetocardiogram (MCG). The first 20 years of MCG research established most of the concepts, instrumentation, and computational algorithms in the field. Additional insights into fundamental mechanisms of biomagnetism were gained by studying isolated hearts or even isolated pieces of cardiac tissue. Much effort has gone into calculating the MCG using computer models, including solving the inverse problem of deducing the bioelectric sources from biomagnetic measurements. Recently, most magnetocardiographic research has focused on clinical applications, driven in part by new technologies to measure weak biomagnetic fields.
Collapse
Affiliation(s)
- Bradley J. Roth
- Department of Physics, Oakland University, Rochester, Michigan 48309, USA
| |
Collapse
|
2
|
Rapp PE, Keyser DO, Albano A, Hernandez R, Gibson DB, Zambon RA, Hairston WD, Hughes JD, Krystal A, Nichols AS. Traumatic brain injury detection using electrophysiological methods. Front Hum Neurosci 2015; 9:11. [PMID: 25698950 PMCID: PMC4316720 DOI: 10.3389/fnhum.2015.00011] [Citation(s) in RCA: 74] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2014] [Accepted: 01/07/2015] [Indexed: 11/20/2022] Open
Abstract
Measuring neuronal activity with electrophysiological methods may be useful in detecting neurological dysfunctions, such as mild traumatic brain injury (mTBI). This approach may be particularly valuable for rapid detection in at-risk populations including military service members and athletes. Electrophysiological methods, such as quantitative electroencephalography (qEEG) and recording event-related potentials (ERPs) may be promising; however, the field is nascent and significant controversy exists on the efficacy and accuracy of the approaches as diagnostic tools. For example, the specific measures derived from an electroencephalogram (EEG) that are most suitable as markers of dysfunction have not been clearly established. A study was conducted to summarize and evaluate the statistical rigor of evidence on the overall utility of qEEG as an mTBI detection tool. The analysis evaluated qEEG measures/parameters that may be most suitable as fieldable diagnostic tools, identified other types of EEG measures and analysis methods of promise, recommended specific measures and analysis methods for further development as mTBI detection tools, identified research gaps in the field, and recommended future research and development thrust areas. The qEEG study group formed the following conclusions: (1) Individual qEEG measures provide limited diagnostic utility for mTBI. However, many measures can be important features of qEEG discriminant functions, which do show significant promise as mTBI detection tools. (2) ERPs offer utility in mTBI detection. In fact, evidence indicates that ERPs can identify abnormalities in cases where EEGs alone are non-disclosing. (3) The standard mathematical procedures used in the characterization of mTBI EEGs should be expanded to incorporate newer methods of analysis including non-linear dynamical analysis, complexity measures, analysis of causal interactions, graph theory, and information dynamics. (4) Reports of high specificity in qEEG evaluations of TBI must be interpreted with care. High specificities have been reported in carefully constructed clinical studies in which healthy controls were compared against a carefully selected TBI population. The published literature indicates, however, that similar abnormalities in qEEG measures are observed in other neuropsychiatric disorders. While it may be possible to distinguish a clinical patient from a healthy control participant with this technology, these measures are unlikely to discriminate between, for example, major depressive disorder, bipolar disorder, or TBI. The specificities observed in these clinical studies may well be lost in real world clinical practice. (5) The absence of specificity does not preclude clinical utility. The possibility of use as a longitudinal measure of treatment response remains. However, efficacy as a longitudinal clinical measure does require acceptable test-retest reliability. To date, very few test-retest reliability studies have been published with qEEG data obtained from TBI patients or from healthy controls. This is a particular concern because high variability is a known characteristic of the injured central nervous system.
Collapse
Affiliation(s)
- Paul E. Rapp
- Uniformed Services University of the Health Sciences School of Medicine, Bethesda, MD, USA
| | - David O. Keyser
- Uniformed Services University of the Health Sciences School of Medicine, Bethesda, MD, USA
| | | | - Rene Hernandez
- US Navy Bureau of Medicine and Surgery, Frederick, MD, USA
| | | | | | - W. David Hairston
- U. S. Army Research Laboratory, Aberdeen Proving Ground, Aberdeen, MD, USA
| | | | | | | |
Collapse
|
3
|
Forward and inverse electroencephalographic modeling in health and in acute traumatic brain injury. Clin Neurophysiol 2013; 124:2129-45. [PMID: 23746499 DOI: 10.1016/j.clinph.2013.04.336] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2013] [Revised: 04/04/2013] [Accepted: 04/17/2013] [Indexed: 11/20/2022]
Abstract
OBJECTIVE EEG source localization is demonstrated in three cases of acute traumatic brain injury (TBI) with progressive lesion loads using anatomically faithful models of the head which account for pathology. METHODS Multimodal magnetic resonance imaging (MRI) volumes were used to generate head models via the finite element method (FEM). A total of 25 tissue types-including 6 types accounting for pathology-were included. To determine the effects of TBI upon source localization accuracy, a minimum-norm operator was used to perform inverse localization and to determine the accuracy of the latter. RESULTS The importance of using a more comprehensive number of tissue types is confirmed in both health and in TBI. Pathology omission is found to cause substantial inaccuracies in EEG forward matrix calculations, with lead field sensitivity being underestimated by as much as ≈ 200% in (peri-) contusional regions when TBI-related changes are ignored. Failing to account for such conductivity changes is found to misestimate substantial localization error by up to 35 mm. CONCLUSIONS Changes in head conductivity profiles should be accounted for when performing EEG modeling in acute TBI. SIGNIFICANCE Given the challenges of inverse localization in TBI, this framework can benefit neurotrauma patients by providing useful insights on pathophysiology.
Collapse
|
4
|
Brisinda D, Sorbo AR, Venuti A, Fenici R. Percutaneous method for single-catheter multiple monophasic action potential recordings during magnetocardiographic mapping in spontaneously breathing rodents. Physiol Meas 2012; 33:521-34. [PMID: 22373565 DOI: 10.1088/0967-3334/33/3/521] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
To test the feasibility of a novel method to combine magnetocardiographic (MCG) estimate of ventricular repolarization (VR) and multiple monophasic action potential (MultiMAP) recording in spontaneously breathing rodents with percutaneous sub-xyphoid epicardial placement of a MCG-compatible amagnetic catheter (AC), ten Wistar rats (WRs) and ten guinea pigs (GPs) were studied. Under fluoroscopic control, the AC was moved until four stable MAPs were recorded (fixed inter-electrode distance of 1.2 mm). 36-channel DC-SQUID (sensitivity 20 fT Hz(-½)) were used for MCG mapping. MAPs, differentially amplified (BW: DC-500 Hz), were digitized at 1 kHz. AC pacing provided local ventricular effective refractory period (VERP) estimate. MAP duration (MAPd) was measured at 50% and 90% levels of repolarization. Simultaneous MCG mapping and MultiMAP recording were successful in all animals. Average MAPd50% and MAPd90% were shorter in WRs than in GPs (26.4 ± 2.9 ms versus 110.6 ± 14.3 ms and 60.7 ± 5.4 ms versus 127.7 ± 15.3 ms, respectively). VERP was 51 ± 4.8 ms in WRs and 108.4 ± 12.9 ms in GPs, respectively. The MAP amplitude was 16.9 ± 4.5 in WRs and 16.2 ± 4.2 in GPs. MAP and MCG parameters of VR were in good agreement. All animals survived the procedure. Two also survived a second invasive study; one was followed up until natural death at 52 months. Percutaneous MultiMAP recording is minimally invasive, usually avoids animal sacrifice, is compatible with simultaneous surface MCG mapping and might be used for experimental validation of MCG VR abnormality, to study the arrhythmogenic potential of new drugs and/or animal models of ventricular arrhythmias.
Collapse
Affiliation(s)
- Donatella Brisinda
- Clinical Physiology-Biomagnetism Center, Catholic University of Sacred Heart, Rome, Italy
| | | | | | | |
Collapse
|
5
|
Open database of epileptic EEG with MRI and postoperational assessment of foci--a real world verification for the EEG inverse solutions. Neuroinformatics 2011; 8:285-99. [PMID: 20872095 PMCID: PMC2974908 DOI: 10.1007/s12021-010-9086-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
This paper introduces a freely accessible database http://eeg.pl/epi, containing 23 datasets from patients diagnosed with and operated on for drug-resistant epilepsy. This was collected as part of the clinical routine at the Warsaw Memorial Child Hospital. Each record contains (1) pre-surgical electroencephalography (EEG) recording (10–20 system) with inter-ictal discharges marked separately by an expert, (2) a full set of magnetic resonance imaging (MRI) scans for calculations of the realistic forward models, (3) structural placement of the epileptogenic zone, recognized by electrocorticography (ECoG) and post-surgical results, plotted on pre-surgical MRI scans in transverse, sagittal and coronal projections, (4) brief clinical description of each case. The main goal of this project is evaluation of possible improvements of localization of epileptic foci from the surface EEG recordings. These datasets offer a unique possibility for evaluating different EEG inverse solutions. We present preliminary results from a subset of these cases, including comparison of different schemes for the EEG inverse solution and preprocessing. We report also a finding which relates to the selective parametrization of single waveforms by multivariate matching pursuit, which is used in the preprocessing for the inverse solutions. It seems to offer a possibility of tracing the spatial evolution of seizures in time.
Collapse
|