• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4632649)   Today's Articles (85)   Subscriber (49912)
For: Kaewuam R, Tan TR, Arnold KJ, Chanu SR, Zhang Z, Barrett MD. Hyperfine Averaging by Dynamic Decoupling in a Multi-Ion Lutetium Clock. Phys Rev Lett 2020;124:083202. [PMID: 32167337 DOI: 10.1103/physrevlett.124.083202] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Accepted: 02/03/2020] [Indexed: 06/10/2023]
Number Cited by Other Article(s)
1
Pelzer L, Dietze K, Martínez-Lahuerta VJ, Krinner L, Kramer J, Dawel F, Spethmann NCH, Hammerer K, Schmidt PO. Multi-ion Frequency Reference Using Dynamical Decoupling. PHYSICAL REVIEW LETTERS 2024;133:033203. [PMID: 39094148 DOI: 10.1103/physrevlett.133.033203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 05/07/2024] [Accepted: 05/22/2024] [Indexed: 08/04/2024]
2
Zhiqiang Z, Arnold KJ, Kaewuam R, Barrett MD. 176Lu+ clock comparison at the 10-18 level via correlation spectroscopy. SCIENCE ADVANCES 2023;9:eadg1971. [PMID: 37134164 PMCID: PMC10156108 DOI: 10.1126/sciadv.adg1971] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
3
Simultaneous bicolor interrogation in thulium optical clock providing very low systematic frequency shifts. Nat Commun 2021;12:5171. [PMID: 34453046 PMCID: PMC8397736 DOI: 10.1038/s41467-021-25396-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 08/05/2021] [Indexed: 11/25/2022]  Open
4
Beloy K. Prospects of a Pb^{2+} Ion Clock. PHYSICAL REVIEW LETTERS 2021;127:013201. [PMID: 34270290 PMCID: PMC10202158 DOI: 10.1103/physrevlett.127.013201] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Accepted: 05/17/2021] [Indexed: 05/24/2023]
5
Nordmann T, Didier A, Doležal M, Balling P, Burgermeister T, Mehlstäubler TE. Sub-kelvin temperature management in ion traps for optical clocks. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020;91:111301. [PMID: 33261420 DOI: 10.1063/5.0024693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Accepted: 10/22/2020] [Indexed: 06/12/2023]
6
Lange R, Huntemann N, Sanner C, Shao H, Lipphardt B, Tamm C, Peik E. Coherent Suppression of Tensor Frequency Shifts through Magnetic Field Rotation. PHYSICAL REVIEW LETTERS 2020;125:143201. [PMID: 33064511 DOI: 10.1103/physrevlett.125.143201] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Accepted: 08/24/2020] [Indexed: 06/11/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA