1
|
Pelzer L, Dietze K, Martínez-Lahuerta VJ, Krinner L, Kramer J, Dawel F, Spethmann NCH, Hammerer K, Schmidt PO. Multi-ion Frequency Reference Using Dynamical Decoupling. PHYSICAL REVIEW LETTERS 2024; 133:033203. [PMID: 39094148 DOI: 10.1103/physrevlett.133.033203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 05/07/2024] [Accepted: 05/22/2024] [Indexed: 08/04/2024]
Abstract
We present the experimental realization of a continuous dynamical decoupling scheme which suppresses leading frequency shifts in a multi-ion frequency reference based on ^{40}Ca^{+}. By near-resonant magnetic coupling of the ^{2}S_{1/2} and ^{2}D_{5/2} Zeeman sublevels using radio-frequency dressing fields, engineered transitions with reduced sensitivity to magnetic-field fluctuations are obtained. A second stage detuned dressing field reduces the influence of amplitude noise in the first stage driving fields and decreases 2nd-rank tensor shifts, such as the electric quadrupole shift. Suppression of the quadratic dependence of the quadrupole shift to 3(2) mHz/μm^{2} and coherence times of 290(20) ms on the optical transition are demonstrated even within a laboratory environment with significant magnetic field noise. Besides removing inhomogeneous line shifts in multi-ion clocks, the demonstrated dynamical decoupling technique may find applications in quantum computing and simulation with trapped ions by a tailored design of decoherence-free subspaces.
Collapse
|
2
|
Zhiqiang Z, Arnold KJ, Kaewuam R, Barrett MD. 176Lu + clock comparison at the 10 -18 level via correlation spectroscopy. SCIENCE ADVANCES 2023; 9:eadg1971. [PMID: 37134164 PMCID: PMC10156108 DOI: 10.1126/sciadv.adg1971] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The extreme precision of optical atomic clocks has led to an anticipated redefinition of the second by the International System of Units. Furthermore, accuracies pushing the boundary of 1 part in 1018 and beyond will enable new applications, such as in geodesy and tests of fundamental physics. The 1S0 to 3D1 optical transition in 176Lu+ has exceptionally low sensitivity to external perturbations, making it suitable for practical clock implementations with inaccuracy at or below 10-18. Here, we perform high-accuracy comparisons between two 176Lu+ references using correlation spectroscopy. A comparison at different magnetic fields is used to obtain a quadratic Zeeman coefficient of -4.89264(88) Hz/mT for the reference frequency. With a subsequent comparison at low field, we demonstrate agreement at the low 10-18 level, statistically limited by the averaging time of 42 hours. The evaluated uncertainty in the frequency difference is 9 × 10-19 and the lowest reported in comparing independent optical references.
Collapse
Affiliation(s)
- Zhang Zhiqiang
- Centre for Quantum Technologies, 3 Science Drive 2, Singapore 117543, Singapore
| | - Kyle J Arnold
- Centre for Quantum Technologies, 3 Science Drive 2, Singapore 117543, Singapore
- Temasek Laboratories, National University of Singapore, 5A Engineering Drive 1, Singapore 117411, Singapore
| | - Rattakorn Kaewuam
- Centre for Quantum Technologies, 3 Science Drive 2, Singapore 117543, Singapore
- National Institute of Metrology, 3 4 Khlong Ha, Khlong Luang District, Pathum Thani 12120, Thailand
| | - Murray D Barrett
- Centre for Quantum Technologies, 3 Science Drive 2, Singapore 117543, Singapore
- Department of Physics, National University of Singapore, 2 Science Drive 3, Singapore 117551, Singapore
- National Metrology Center, 8 Cleantech Loop, 01-20, Singapore 637145, Singapore
| |
Collapse
|
3
|
Simultaneous bicolor interrogation in thulium optical clock providing very low systematic frequency shifts. Nat Commun 2021; 12:5171. [PMID: 34453046 PMCID: PMC8397736 DOI: 10.1038/s41467-021-25396-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 08/05/2021] [Indexed: 11/25/2022] Open
Abstract
Optical atomic clocks have already overcome the eighteenth decimal digit of instability and uncertainty, demonstrating incredible control over external perturbations of the clock transition frequency. At the same time, there is an increasing demand for atomic (ionic) transitions and new interrogation and readout protocols providing minimal sensitivity to external fields and possessing practical operational wavelengths. One of the goals is to simplify the clock operation while maintaining the relative uncertainty at a low 10−18 level achieved at the shortest averaging time. This is especially important for transportable and envisioned space-based optical clocks. Here, we demonstrate implementation of a synthetic frequency approach for a thulium optical clock with simultaneous optical interrogation of two clock transitions. Our experiment shows suppression of the quadratic Zeeman shift by at least three orders of magnitude. The effect of the tensor lattice Stark shift in thulium can also be reduced to below 10−18 in fractional frequency units. This makes the thulium optical clock almost free from hard-to-control systematic shifts. The “simultaneous” protocol demonstrates very low sensitivity to the cross-talks between individual clock transitions during interrogation and readout. There are continuous efforts in improving the stability and systematic shifts of optical clocks. Here the authors demonstrate thulium optical clock utilizing bicolor scheme involving interrogation of both hyperfine levels and they are able to cancel the quadratic Zeeman shift.
Collapse
|
4
|
Beloy K. Prospects of a Pb^{2+} Ion Clock. PHYSICAL REVIEW LETTERS 2021; 127:013201. [PMID: 34270290 PMCID: PMC10202158 DOI: 10.1103/physrevlett.127.013201] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Accepted: 05/17/2021] [Indexed: 05/24/2023]
Abstract
We propose a high-performance atomic clock based on the 1.81 PHz transition between the ground and first-excited state of doubly ionized lead. Utilizing an even isotope of lead, both clock states have I=J=F=0, where I, J, and F are the conventional quantum numbers specifying nuclear, electronic, and total angular momentum, respectively. The clock states are nondegenerate and completely immune to nonscalar perturbations, including first order Zeeman and electric quadrupole shifts. Additionally, the proposed clock is relatively insusceptible to other frequency shifts (blackbody radiation, second order Zeeman, Doppler), accommodates "magic" rf trapping, and is robust against decoherence mechanisms that can otherwise limit clock stability. By driving the transition as a two-photon E1+M1 process, the accompanying probe Stark shift is appreciable yet manageable for practical Rabi frequencies.
Collapse
|
5
|
Nordmann T, Didier A, Doležal M, Balling P, Burgermeister T, Mehlstäubler TE. Sub-kelvin temperature management in ion traps for optical clocks. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:111301. [PMID: 33261420 DOI: 10.1063/5.0024693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Accepted: 10/22/2020] [Indexed: 06/12/2023]
Abstract
The uncertainty of the ac Stark shift due to thermal radiation represents a major contribution to the systematic uncertainty budget of state-of-the-art optical atomic clocks. In the case of optical clocks based on trapped ions, the thermal behavior of the rf-driven ion trap must be precisely known. This determination is even more difficult when scalable linear ion traps are used. Such traps enable a more advanced control of multiple ions and have become a platform for new applications in quantum metrology, simulation, and computation. Nevertheless, their complex structure makes it more difficult to precisely determine its temperature in operation and thus the related systematic uncertainty. We present here scalable linear ion traps for optical clocks, which exhibit very low temperature rise under operation. We use a finite-element model refined with experimental measurements to determine the thermal distribution in the ion trap and the temperature at the position of the ions. The trap temperature is investigated at different rf-drive frequencies and amplitudes with an infrared camera and integrated temperature sensors. We show that for typical trapping parameters for In+, Al+, Lu+, Ca+, Sr+, or Yb+ ions, the temperature rise at the position of the ions resulting from rf heating of the trap stays below 700 mK and can be controlled with an uncertainty on the order of a few 100 mK maximum. The corresponding uncertainty of the trap-related blackbody radiation shift is in the low 10-19 and even 10-20 regime for 171Yb+(E3) and 115In+, respectively.
Collapse
Affiliation(s)
- T Nordmann
- Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany
| | - A Didier
- Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany
| | - M Doležal
- Czech Metrology Institute (CMI), Okružní 31, 638 00 Brno, Czech Republic
| | - P Balling
- Czech Metrology Institute (CMI), Okružní 31, 638 00 Brno, Czech Republic
| | - T Burgermeister
- Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany
| | - T E Mehlstäubler
- Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany
| |
Collapse
|
6
|
Lange R, Huntemann N, Sanner C, Shao H, Lipphardt B, Tamm C, Peik E. Coherent Suppression of Tensor Frequency Shifts through Magnetic Field Rotation. PHYSICAL REVIEW LETTERS 2020; 125:143201. [PMID: 33064511 DOI: 10.1103/physrevlett.125.143201] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Accepted: 08/24/2020] [Indexed: 06/11/2023]
Abstract
We introduce a scheme to coherently suppress second-rank tensor frequency shifts in atomic clocks, relying on the continuous rotation of an external magnetic field during the free atomic state evolution in a Ramsey sequence. The method retrieves the unperturbed frequency within a single interrogation cycle and is readily applicable to various atomic clock systems. For the frequency shift due to the electric quadrupole interaction, we experimentally demonstrate suppression by more than two orders of magnitude for the ^{2}S_{1/2}→^{2}D_{3/2} transition of a single trapped ^{171}Yb^{+} ion. The scheme provides particular advantages in the case of the ^{171}Yb^{+} ^{2}S_{1/2}→^{2}F_{7/2} electric octupole (E3) transition. For an improved estimate of the residual quadrupole shift for this transition, we measure the excited state electric quadrupole moments Θ(^{2}D_{3/2})=1.95(1)ea_{0}^{2} and Θ(^{2}F_{7/2})=-0.0297(5)ea_{0}^{2} with e the elementary charge and a_{0} the Bohr radius, improving the measurement uncertainties by one order of magnitude.
Collapse
Affiliation(s)
- R Lange
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| | - N Huntemann
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| | - C Sanner
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| | - H Shao
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| | - B Lipphardt
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| | - Chr Tamm
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| | - E Peik
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| |
Collapse
|