1
|
Mehrabi P, Schulz EC. Sample Preparation for Time-Resolved Serial Crystallography: Practical Considerations. Methods Mol Biol 2023; 2652:361-379. [PMID: 37093487 DOI: 10.1007/978-1-0716-3147-8_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2023]
Abstract
Time-resolved serial crystallography is an emerging method to elucidate the structure-function relationship of biomolecular systems at up to atomic resolution. However, to make this demanding method a success, a number of experimental requirements have to be met. In this chapter, we summarize general guidelines and protocols towards performing time-resolved crystallography experiments, with a particular emphasis on sample requirements and preparation but also a brief excursion into reaction initiation.
Collapse
Affiliation(s)
- Pedram Mehrabi
- Institute for Nanostructure and Solid State Physics, Universität Hamburg, Hamburg, Germany.
- Max Planck Institute for Structure and Dynamics of Matter, Hamburg, Germany.
| | - Eike C Schulz
- Max Planck Institute for Structure and Dynamics of Matter, Hamburg, Germany.
- University Medical Center Hamburg-Eppendorf (UKE), Hamburg, Germany.
| |
Collapse
|
2
|
Martiel I, Beale JH, Karpik A, Huang CY, Vera L, Olieric N, Wranik M, Tsai CJ, Mühle J, Aurelius O, John J, Högbom M, Wang M, Marsh M, Padeste C. Versatile microporous polymer-based supports for serial macromolecular crystallography. Acta Crystallogr D Struct Biol 2021; 77:1153-1167. [PMID: 34473086 PMCID: PMC8411977 DOI: 10.1107/s2059798321007324] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Accepted: 07/15/2021] [Indexed: 11/10/2022] Open
Abstract
Serial data collection has emerged as a major tool for data collection at state-of-the-art light sources, such as microfocus beamlines at synchrotrons and X-ray free-electron lasers. Challenging targets, characterized by small crystal sizes, weak diffraction and stringent dose limits, benefit most from these methods. Here, the use of a thin support made of a polymer-based membrane for performing serial data collection or screening experiments is demonstrated. It is shown that these supports are suitable for a wide range of protein crystals suspended in liquids. The supports have also proved to be applicable to challenging cases such as membrane proteins growing in the sponge phase. The sample-deposition method is simple and robust, as well as flexible and adaptable to a variety of cases. It results in an optimally thin specimen providing low background while maintaining minute amounts of mother liquor around the crystals. The 2 × 2 mm area enables the deposition of up to several microlitres of liquid. Imaging and visualization of the crystals are straightforward on the highly transparent membrane. Thanks to their affordable fabrication, these supports have the potential to become an attractive option for serial experiments at synchrotrons and free-electron lasers.
Collapse
Affiliation(s)
- Isabelle Martiel
- Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland
| | - John H. Beale
- Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland
| | - Agnieszka Karpik
- Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland
- Institute of Polymer Nanotechnology (INKA), FHNW University of Applied Sciences and Arts Northwestern Switzerland, 5210 Windisch, Switzerland
| | - Chia-Ying Huang
- Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland
| | - Laura Vera
- Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland
| | - Natacha Olieric
- Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland
| | - Maximilian Wranik
- Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland
| | - Ching-Ju Tsai
- Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland
| | - Jonas Mühle
- Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland
| | - Oskar Aurelius
- Department of Biochemistry and Biophysics, Stockholm University, 106 91 Stockholm, Sweden
- MAX IV Laboratory, Lund University, Fotongatan 2, 224 84 Lund, Sweden
| | - Juliane John
- Department of Biochemistry and Biophysics, Stockholm University, 106 91 Stockholm, Sweden
| | - Martin Högbom
- Department of Biochemistry and Biophysics, Stockholm University, 106 91 Stockholm, Sweden
| | - Meitian Wang
- Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland
| | - May Marsh
- Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland
| | - Celestino Padeste
- Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland
| |
Collapse
|
3
|
Norton-Baker B, Mehrabi P, Boger J, Schönherr R, von Stetten D, Schikora H, Kwok AO, Martin RW, Miller RJD, Redecke L, Schulz EC. A simple vapor-diffusion method enables protein crystallization inside the HARE serial crystallography chip. Acta Crystallogr D Struct Biol 2021; 77:820-834. [PMID: 34076595 PMCID: PMC8171066 DOI: 10.1107/s2059798321003855] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Accepted: 04/10/2021] [Indexed: 11/12/2022] Open
Abstract
Fixed-target serial crystallography has become an important method for the study of protein structure and dynamics at synchrotrons and X-ray free-electron lasers. However, sample homogeneity, consumption and the physical stress on samples remain major challenges for these high-throughput experiments, which depend on high-quality protein microcrystals. The batch crystallization procedures that are typically applied require time- and sample-intensive screening and optimization. Here, a simple protein crystallization method inside the features of the HARE serial crystallography chips is reported that circumvents batch crystallization and allows the direct transfer of canonical vapor-diffusion conditions to in-chip crystallization. Based on conventional hanging-drop vapor-diffusion experiments, the crystallization solution is distributed into the wells of the HARE chip and equilibrated against a reservoir with mother liquor. Using this simple method, high-quality microcrystals were generated with sufficient density for the structure determination of four different proteins. A new protein variant was crystallized using the protein concentrations encountered during canonical crystallization experiments, enabling structure determination from ∼55 µg of protein. Additionally, structure determination from intracellular crystals grown in insect cells cultured directly in the features of the HARE chips is demonstrated. In cellulo crystallization represents a comparatively unexplored space in crystallization, especially for proteins that are resistant to crystallization using conventional techniques, and eliminates any need for laborious protein purification. This in-chip technique avoids harvesting the sensitive crystals or any further physical handling of the crystal-containing cells. These proof-of-principle experiments indicate the potential of this method to become a simple alternative to batch crystallization approaches and also as a convenient extension to canonical crystallization screens.
Collapse
Affiliation(s)
- Brenna Norton-Baker
- Department for Atomically Resolved Dynamics, Max-Planck-Institute for Structure and Dynamics of Matter, Luruper Chaussee 149, 22761 Hamburg, Germany
- Department of Chemistry, University of California, Irvine, CA 92697-2025, USA
| | - Pedram Mehrabi
- Department for Atomically Resolved Dynamics, Max-Planck-Institute for Structure and Dynamics of Matter, Luruper Chaussee 149, 22761 Hamburg, Germany
- Hamburg Centre for Ultrafast Imaging, Universität Hamburg, HARBOR, Luruper Chaussee 149, 22761 Hamburg, Germany
| | - Juliane Boger
- Institute of Biochemistry, Center for Structural and Cell Biology in Medicine, University of Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany
| | - Robert Schönherr
- Institute of Biochemistry, Center for Structural and Cell Biology in Medicine, University of Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany
- Photon Science, Deutsches Elektronen-Synchrotron (DESY), Notkestrasse 85, 22607 Hamburg, Germany
| | - David von Stetten
- European Molecular Biology Laboratory, Hamburg Unit c/o Deutsches Elektronen-Synchrotron, 22607 Hamburg, Germany
| | - Hendrik Schikora
- Scientific Support Unit Machine Physics, Max-Planck-Institute for Structure and Dynamics of Matter, Luruper Chaussee 149, 22761 Hamburg, Germany
| | - Ashley O. Kwok
- Department of Chemistry, University of California, Irvine, CA 92697-2025, USA
| | - Rachel W. Martin
- Department of Chemistry, University of California, Irvine, CA 92697-2025, USA
- Department of Molecular Biology and Biochemistry, University of California, Irvine, CA 92697-3900, USA
| | - R. J. Dwayne Miller
- Department of Physics, Universität Hamburg, Jungiusstrasse 9, 20355 Hamburg, Germany
- Departments of Chemistry and Physics, University of Toronto, 80 St George Street, Toronto, ON M5S 3H6, Canada
| | - Lars Redecke
- Institute of Biochemistry, Center for Structural and Cell Biology in Medicine, University of Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany
- Photon Science, Deutsches Elektronen-Synchrotron (DESY), Notkestrasse 85, 22607 Hamburg, Germany
| | - Eike C. Schulz
- Department for Atomically Resolved Dynamics, Max-Planck-Institute for Structure and Dynamics of Matter, Luruper Chaussee 149, 22761 Hamburg, Germany
- Hamburg Centre for Ultrafast Imaging, Universität Hamburg, HARBOR, Luruper Chaussee 149, 22761 Hamburg, Germany
| |
Collapse
|
4
|
Shilova A, Lebrette H, Aurelius O, Nan J, Welin M, Kovacic R, Ghosh S, Safari C, Friel RJ, Milas M, Matej Z, Högbom M, Brändén G, Kloos M, Shoeman RL, Doak B, Ursby T, Håkansson M, Logan DT, Mueller U. Current status and future opportunities for serial crystallography at MAX IV Laboratory. JOURNAL OF SYNCHROTRON RADIATION 2020; 27:1095-1102. [PMID: 32876583 PMCID: PMC7467353 DOI: 10.1107/s1600577520008735] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Accepted: 06/28/2020] [Indexed: 06/11/2023]
Abstract
Over the last decade, serial crystallography, a method to collect complete diffraction datasets from a large number of microcrystals delivered and exposed to an X-ray beam in random orientations at room temperature, has been successfully implemented at X-ray free-electron lasers and synchrotron radiation facility beamlines. This development relies on a growing variety of sample presentation methods, including different fixed target supports, injection methods using gas-dynamic virtual-nozzle injectors and high-viscosity extrusion injectors, and acoustic levitation of droplets, each with unique requirements. In comparison with X-ray free-electron lasers, increased beam time availability makes synchrotron facilities very attractive to perform serial synchrotron X-ray crystallography (SSX) experiments. Within this work, the possibilities to perform SSX at BioMAX, the first macromolecular crystallography beamline at MAX IV Laboratory in Lund, Sweden, are described, together with case studies from the SSX user program: an implementation of a high-viscosity extrusion injector to perform room temperature serial crystallography at BioMAX using two solid supports - silicon nitride membranes (Silson, UK) and XtalTool (Jena Bioscience, Germany). Future perspectives for the dedicated serial crystallography beamline MicroMAX at MAX IV Laboratory, which will provide parallel and intense micrometre-sized X-ray beams, are discussed.
Collapse
Affiliation(s)
- Anastasya Shilova
- MAX IV Laboratory, Lund University, Fotongatan 2, Lund 22484, Sweden
| | - Hugo Lebrette
- Department of Biochemistry and Biophysics, Stockholm University, Svante Arrhenius väg 16 C, Stockholm 10691, Sweden
| | - Oskar Aurelius
- MAX IV Laboratory, Lund University, Fotongatan 2, Lund 22484, Sweden
| | - Jie Nan
- MAX IV Laboratory, Lund University, Fotongatan 2, Lund 22484, Sweden
| | - Martin Welin
- SARomics Biostructures, Medicon Village, Scheeletorget 1, Lund 22363, Sweden
| | - Rebeka Kovacic
- SARomics Biostructures, Medicon Village, Scheeletorget 1, Lund 22363, Sweden
| | - Swagatha Ghosh
- Department of Chemistry and Molecular Biology, University of Gothenburg, Gothenburg 40530, Sweden
| | - Cecilia Safari
- Department of Chemistry and Molecular Biology, University of Gothenburg, Gothenburg 40530, Sweden
| | - Ross J. Friel
- School of Information Technology, Halmstad University, Halmstad 30118, Sweden
| | - Mirko Milas
- MAX IV Laboratory, Lund University, Fotongatan 2, Lund 22484, Sweden
| | - Zdenek Matej
- MAX IV Laboratory, Lund University, Fotongatan 2, Lund 22484, Sweden
| | - Martin Högbom
- Department of Biochemistry and Biophysics, Stockholm University, Svante Arrhenius väg 16 C, Stockholm 10691, Sweden
| | - Gisela Brändén
- Department of Chemistry and Molecular Biology, University of Gothenburg, Gothenburg 40530, Sweden
| | - Marco Kloos
- European XFEL GmbH, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Robert L. Shoeman
- Department of Biomolecular Mechanisms, Max Planck Institute for Medical Research, Jahnstrasse 29, 69120 Heidelberg, Germany
| | - Bruce Doak
- Department of Biomolecular Mechanisms, Max Planck Institute for Medical Research, Jahnstrasse 29, 69120 Heidelberg, Germany
| | - Thomas Ursby
- MAX IV Laboratory, Lund University, Fotongatan 2, Lund 22484, Sweden
| | - Maria Håkansson
- SARomics Biostructures, Medicon Village, Scheeletorget 1, Lund 22363, Sweden
| | - Derek T. Logan
- SARomics Biostructures, Medicon Village, Scheeletorget 1, Lund 22363, Sweden
| | - Uwe Mueller
- MAX IV Laboratory, Lund University, Fotongatan 2, Lund 22484, Sweden
- Macromolecular Crystallography Group, Helmholtz-Zentrum Berlin, Albert-Einstein-Strasse 15, 12489 Berlin, Germany
| |
Collapse
|
5
|
Abstract
The advent of the X-ray free electron laser (XFEL) in the last decade created the discipline of serial crystallography but also the challenge of how crystal samples are delivered to X-ray. Early sample delivery methods demonstrated the proof-of-concept for serial crystallography and XFEL but were beset with challenges of high sample consumption, jet clogging and low data collection efficiency. The potential of XFEL and serial crystallography as the next frontier of structural solution by X-ray for small and weakly diffracting crystals and provision of ultra-fast time-resolved structural data spawned a huge amount of scientific interest and innovation. To utilize the full potential of XFEL and broaden its applicability to a larger variety of biological samples, researchers are challenged to develop better sample delivery methods. Thus, sample delivery is one of the key areas of research and development in the serial crystallography scientific community. Sample delivery currently falls into three main systems: jet-based methods, fixed-target chips, and drop-on-demand. Huge strides have since been made in reducing sample consumption and improving data collection efficiency, thus enabling the use of XFEL for many biological systems to provide high-resolution, radiation damage-free structural data as well as time-resolved dynamics studies. This review summarizes the current main strategies in sample delivery and their respective pros and cons, as well as some future direction.
Collapse
|
6
|
Martiel I, Mozzanica A, Opara NL, Panepucci E, Leonarski F, Redford S, Mohacsi I, Guzenko V, Ozerov D, Padeste C, Schmitt B, Pedrini B, Wang M. X-ray fluorescence detection for serial macromolecular crystallography using a JUNGFRAU pixel detector. JOURNAL OF SYNCHROTRON RADIATION 2020; 27:329-339. [PMID: 32153271 PMCID: PMC7064105 DOI: 10.1107/s1600577519016758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2019] [Accepted: 12/14/2019] [Indexed: 05/06/2023]
Abstract
Detection of heavy elements, such as metals, in macromolecular crystallography (MX) samples by X-ray fluorescence is a function traditionally covered at synchrotron MX beamlines by silicon drift detectors, which cannot be used at X-ray free-electron lasers because of the very short duration of the X-ray pulses. Here it is shown that the hybrid pixel charge-integrating detector JUNGFRAU can fulfill this function when operating in a low-flux regime. The feasibility of precise position determination of micrometre-sized metal marks is also demonstrated, to be used as fiducials for offline prelocation in serial crystallography experiments, based on the specific fluorescence signal measured with JUNGFRAU, both at the synchrotron and at SwissFEL. Finally, the measurement of elemental absorption edges at a synchrotron beamline using JUNGFRAU is also demonstrated.
Collapse
Affiliation(s)
- Isabelle Martiel
- Paul Scherrer Institute, Forschungsstrasse 111, Villigen 5232, Switzerland
| | - Aldo Mozzanica
- Paul Scherrer Institute, Forschungsstrasse 111, Villigen 5232, Switzerland
| | - Nadia L. Opara
- Paul Scherrer Institute, Forschungsstrasse 111, Villigen 5232, Switzerland
- Center for Cellular Imaging and NanoAnalytics (C-CINA), Biozentrum, University of Basel, Basel 4058, Switzerland
- SwissNanoscience Institute, University of Basel, Basel 4056, Switzerland
| | - Ezequiel Panepucci
- Paul Scherrer Institute, Forschungsstrasse 111, Villigen 5232, Switzerland
| | - Filip Leonarski
- Paul Scherrer Institute, Forschungsstrasse 111, Villigen 5232, Switzerland
| | - Sophie Redford
- Paul Scherrer Institute, Forschungsstrasse 111, Villigen 5232, Switzerland
| | - Istvan Mohacsi
- Paul Scherrer Institute, Forschungsstrasse 111, Villigen 5232, Switzerland
| | - Vitaliy Guzenko
- Paul Scherrer Institute, Forschungsstrasse 111, Villigen 5232, Switzerland
| | - Dmitry Ozerov
- Paul Scherrer Institute, Forschungsstrasse 111, Villigen 5232, Switzerland
| | - Celestino Padeste
- Paul Scherrer Institute, Forschungsstrasse 111, Villigen 5232, Switzerland
| | - Bernd Schmitt
- Paul Scherrer Institute, Forschungsstrasse 111, Villigen 5232, Switzerland
| | - Bill Pedrini
- Paul Scherrer Institute, Forschungsstrasse 111, Villigen 5232, Switzerland
| | - Meitian Wang
- Paul Scherrer Institute, Forschungsstrasse 111, Villigen 5232, Switzerland
| |
Collapse
|
7
|
Opara N, Martiel I, Arnold SA, Braun T, Stahlberg H, Makita M, David C, Padeste C. Direct protein crystallization on ultrathin membranes for diffraction measurements at X-ray free-electron lasers. Corrigendum. J Appl Crystallogr 2019. [DOI: 10.1107/s1600576719013918] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Errors in the article by Opara, Martiel, Arnold, Braun, Stahlberg, Makita, David & Padeste [J. Appl. Cryst. (2017), 50, 909–918] are corrected.
Collapse
|
8
|
Lieske J, Cerv M, Kreida S, Komadina D, Fischer J, Barthelmess M, Fischer P, Pakendorf T, Yefanov O, Mariani V, Seine T, Ross BH, Crosas E, Lorbeer O, Burkhardt A, Lane TJ, Guenther S, Bergtholdt J, Schoen S, Törnroth-Horsefield S, Chapman HN, Meents A. On-chip crystallization for serial crystallography experiments and on-chip ligand-binding studies. IUCRJ 2019; 6:714-728. [PMID: 31316815 PMCID: PMC6608620 DOI: 10.1107/s2052252519007395] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Accepted: 05/21/2019] [Indexed: 05/18/2023]
Abstract
Efficient and reliable sample delivery has remained one of the bottlenecks for serial crystallography experiments. Compared with other methods, fixed-target sample delivery offers the advantage of significantly reduced sample consumption and shorter data collection times owing to higher hit rates. Here, a new method of on-chip crystallization is reported which allows the efficient and reproducible growth of large numbers of protein crystals directly on micro-patterned silicon chips for in-situ serial crystallography experiments. Crystals are grown by sitting-drop vapor diffusion and previously established crystallization conditions can be directly applied. By reducing the number of crystal-handling steps, the method is particularly well suited for sensitive crystal systems. Excessive mother liquor can be efficiently removed from the crystals by blotting, and no sealing of the fixed-target sample holders is required to prevent the crystals from dehydrating. As a consequence, 'naked' crystals are obtained on the chip, resulting in very low background scattering levels and making the crystals highly accessible for external manipulation such as the application of ligand solutions. Serial diffraction experiments carried out at cryogenic temperatures at a synchrotron and at room temperature at an X-ray free-electron laser yielded high-quality X-ray structures of the human membrane protein aquaporin 2 and two new ligand-bound structures of thermolysin and the human kinase DRAK2. The results highlight the applicability of the method for future high-throughput on-chip screening of pharmaceutical compounds.
Collapse
Affiliation(s)
- Julia Lieske
- Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
- Photon Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
| | - Maximilian Cerv
- Photon Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
| | - Stefan Kreida
- Center for Molecular Protein Science, Department of Biochemistry and Structural Biology, Lund University, Kemicentrum, 221 00 Lund, Sweden
| | - Dana Komadina
- Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
| | - Janine Fischer
- Photon Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
| | - Miriam Barthelmess
- Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
| | - Pontus Fischer
- Photon Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
| | - Tim Pakendorf
- Photon Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
| | - Oleksandr Yefanov
- Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
| | - Valerio Mariani
- Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
| | - Thomas Seine
- Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
- EMBL, Notkestrasse 85, 22607 Hamburg, Germany
| | - Breyan H. Ross
- Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
- Max Planck Institute of Biochemistry, Am Klopferspitz 18, 82152 Martinsried, Germany
| | - Eva Crosas
- Photon Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
| | - Olga Lorbeer
- Photon Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
| | - Anja Burkhardt
- Photon Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
| | - Thomas J. Lane
- Bioscience Division and Linac Coherent Light Source, SLAC National Accelerator Laboratory, Menlo Park, CA 94025, USA
| | - Sebastian Guenther
- Photon Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
| | - Julian Bergtholdt
- Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
| | - Silvan Schoen
- Photon Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
| | - Susanna Törnroth-Horsefield
- Center for Molecular Protein Science, Department of Biochemistry and Structural Biology, Lund University, Kemicentrum, 221 00 Lund, Sweden
| | - Henry N. Chapman
- Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
- Department of Physics, University of Hamburg, Luruper Chaussee 149, 22761 Hamburg, Germany
- Centre for Ultrafast Imaging, University of Hamburg, Luruper Chaussee 149, 22761 Hamburg, Germany
| | - Alke Meents
- Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
- Photon Science, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
| |
Collapse
|
9
|
Górzny M, Opara N, Guzenko V, Cadarso V, Schift H, Li X, Padeste C. Microfabricated silicon chip as lipid membrane sample holder for serial protein crystallography. MICRO AND NANO ENGINEERING 2019. [DOI: 10.1016/j.mne.2019.03.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
10
|
Ingold G, Abela R, Arrell C, Beaud P, Böhler P, Cammarata M, Deng Y, Erny C, Esposito V, Flechsig U, Follath R, Hauri C, Johnson S, Juranic P, Mancini GF, Mankowsky R, Mozzanica A, Oggenfuss RA, Patterson BD, Patthey L, Pedrini B, Rittmann J, Sala L, Savoini M, Svetina C, Zamofing T, Zerdane S, Lemke HT. Experimental station Bernina at SwissFEL: condensed matter physics on femtosecond time scales investigated by X-ray diffraction and spectroscopic methods. JOURNAL OF SYNCHROTRON RADIATION 2019; 26:874-886. [PMID: 31074452 PMCID: PMC6510206 DOI: 10.1107/s160057751900331x] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2018] [Accepted: 03/07/2019] [Indexed: 05/22/2023]
Abstract
The Bernina instrument at the SwissFEL Aramis hard X-ray free-electron laser is designed for studying ultrafast phenomena in condensed matter and material science. Ultrashort pulses from an optical laser system covering a large wavelength range can be used to generate specific non-equilibrium states, whose subsequent temporal evolution can be probed by selective X-ray scattering techniques in the range 2-12 keV. For that purpose, the X-ray beamline is equipped with optical elements which tailor the X-ray beam size and energy, as well as with pulse-to-pulse diagnostics that monitor the X-ray pulse intensity, position, as well as its spectral and temporal properties. The experiments can be performed using multiple interchangeable endstations differing in specialization, diffractometer and X-ray analyser configuration and load capacity for specialized sample environment. After testing the instrument in a series of pilot experiments in 2018, regular user operation begins in 2019.
Collapse
Affiliation(s)
- Gerhard Ingold
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Rafael Abela
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | | | - Paul Beaud
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Pirmin Böhler
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Marco Cammarata
- Institut de Physique de Rennes, Université de Rennes, 35042 Rennes CEDEX, France
| | - Yunpei Deng
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Christian Erny
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Vincent Esposito
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Uwe Flechsig
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Rolf Follath
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Christoph Hauri
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Steven Johnson
- Institute for Quantum Electronics, Eidgenössische Technische Hochschule (ETH) Zürich, CH-8093 Zurich, Switzerland
| | - Pavle Juranic
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | | | - Roman Mankowsky
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Aldo Mozzanica
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | | | | | - Luc Patthey
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Bill Pedrini
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Jochen Rittmann
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Leonardo Sala
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Matteo Savoini
- Institute for Quantum Electronics, Eidgenössische Technische Hochschule (ETH) Zürich, CH-8093 Zurich, Switzerland
| | - Cristian Svetina
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Thierry Zamofing
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Serhane Zerdane
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | | |
Collapse
|
11
|
Martiel I, Müller-Werkmeister HM, Cohen AE. Strategies for sample delivery for femtosecond crystallography. Acta Crystallogr D Struct Biol 2019; 75:160-177. [PMID: 30821705 PMCID: PMC6400256 DOI: 10.1107/s2059798318017953] [Citation(s) in RCA: 65] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2018] [Accepted: 12/19/2018] [Indexed: 11/11/2022] Open
Abstract
Highly efficient data-collection methods are required for successful macromolecular crystallography (MX) experiments at X-ray free-electron lasers (XFELs). XFEL beamtime is scarce, and the high peak brightness of each XFEL pulse destroys the exposed crystal volume. It is therefore necessary to combine diffraction images from a large number of crystals (hundreds to hundreds of thousands) to obtain a final data set, bringing about sample-refreshment challenges that have previously been unknown to the MX synchrotron community. In view of this experimental complexity, a number of sample delivery methods have emerged, each with specific requirements, drawbacks and advantages. To provide useful selection criteria for future experiments, this review summarizes the currently available sample delivery methods, emphasising the basic principles and the specific sample requirements. Two main approaches to sample delivery are first covered: (i) injector methods with liquid or viscous media and (ii) fixed-target methods using large crystals or using microcrystals inside multi-crystal holders or chips. Additionally, hybrid methods such as acoustic droplet ejection and crystal extraction are covered, which combine the advantages of both fixed-target and injector approaches.
Collapse
Affiliation(s)
- Isabelle Martiel
- Swiss Light Source, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Henrike M. Müller-Werkmeister
- Institute of Chemistry – Physical Chemistry, University of Potsdam, Karl-Liebknecht-Strasse 24-25, 14476 Potsdam-Golm, Germany
| | - Aina E. Cohen
- Stanford Synchrotron Radiation Lightsource, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
| |
Collapse
|
12
|
Opara NL, Mohacsi I, Makita M, Castano-Diez D, Diaz A, Juranić P, Marsh M, Meents A, Milne CJ, Mozzanica A, Padeste C, Panneels V, Sikorski M, Song S, Stahlberg H, Vartiainen I, Vera L, Wang M, Willmott PR, David C. Demonstration of femtosecond X-ray pump X-ray probe diffraction on protein crystals. STRUCTURAL DYNAMICS (MELVILLE, N.Y.) 2018; 5:054303. [PMID: 30364211 PMCID: PMC6192410 DOI: 10.1063/1.5050618] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Accepted: 09/12/2018] [Indexed: 05/24/2023]
Abstract
The development of X-ray free-electron lasers (XFELs) has opened the possibility to investigate the ultrafast dynamics of biomacromolecules using X-ray diffraction. Whereas an increasing number of structures solved by means of serial femtosecond crystallography at XFELs is available, the effect of radiation damage on protein crystals during ultrafast exposures has remained an open question. We used a split-and-delay line based on diffractive X-ray optics at the Linac Coherent Light Source XFEL to investigate the time dependence of X-ray radiation damage to lysozyme crystals. For these tests, crystals were delivered to the X-ray beam using a fixed-target approach. The presented experiments provide probe signals at eight different delay times between 19 and 213 femtoseconds after a single pump event, thereby covering the time-scales relevant for femtosecond serial crystallography. Even though significant impact on the crystals was observed at long time scales after exposure with a single X-ray pulse, the collected diffraction data did not show significant signal reduction that could be assigned to beam damage on the crystals in the sampled time window and resolution range. This observation is in agreement with estimations of the applied radiation dose, which in our experiment was clearly below the values expected to cause damage on the femtosecond time scale. The experiments presented here demonstrate the feasibility of time-resolved pump-multiprobe X-ray diffraction experiments on protein crystals.
Collapse
Affiliation(s)
| | | | | | | | - Ana Diaz
- Paul Scherrer Institut, CH-5232 Villigen-PSI, Switzerland
| | - Pavle Juranić
- Paul Scherrer Institut, CH-5232 Villigen-PSI, Switzerland
| | - May Marsh
- Paul Scherrer Institut, CH-5232 Villigen-PSI, Switzerland
| | - Alke Meents
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
| | | | - Aldo Mozzanica
- Paul Scherrer Institut, CH-5232 Villigen-PSI, Switzerland
| | | | | | - Marcin Sikorski
- LCLS, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025, USA
| | - Sanghoon Song
- LCLS, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025, USA
| | | | | | - Laura Vera
- Paul Scherrer Institut, CH-5232 Villigen-PSI, Switzerland
| | - Meitian Wang
- Paul Scherrer Institut, CH-5232 Villigen-PSI, Switzerland
| | | | | |
Collapse
|
13
|
|