1
|
Shelby M, Gilbile D, Grant T, Bauer W, Segelke B, He W, Evans A, Crespo N, Fischer P, Pakendorf T, Hennicke V, Hunter M, Batyuk A, Barthelmess M, Meents A, Kuhl T, Frank M, Coleman M. Crystallization of ApoA1 and ApoE4 nanolipoprotein particles and initial XFEL-based structural studies. CRYSTALS 2020; 10. [PMID: 35686136 PMCID: PMC9175823 DOI: 10.3390/cryst10100886] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Nanolipoprotein particles (NLPs), also called “nanodiscs”, are discoidal particles with a patch of lipid bilayer corralled by apolipoproteins. NLPs have long been of interest due to both their utility as membrane-model systems into which membrane proteins can be inserted and solubilized and their physiological role in lipid and cholesterol transport via HDL and LDL maturation, which are important for human health. Serial femtosecond crystallography (SFX) at X-ray free electron lasers (XFELs) is a powerful approach for structural biology of membrane proteins, which are traditionally difficult to crystallize as large single crystals capable of producing high-quality diffraction suitable for structure determination. To facilitate understanding of the specific role of two apolipoprotein/lipid complexes, ApoA1 and ApoE4, in lipid binding and HDL/LDL particle maturation dynamics and develop new SFX methods involving NLP membrane protein encapsulation, we have prepared and crystallized homogeneous populations of ApoA1 and ApoE4 NLPs. Crystallization of empty NLPs yields semi-ordered objects that appear crystalline and give highly anisotropic and diffuse X-ray diffraction, similar in characteristics to fiber diffraction. Several unit cell parameters were approximately determined for both NLPs from these measurements. Thus, low-background, sample conservative methods of delivery are critical. Here we implemented a fixed target sample delivery scheme utilizing the Roadrunner fast-scanning system and ultra-thin polymer/graphene support films, providing a low-volume, low-background approach to membrane protein SFX. This study represents initial steps in obtaining structural information for ApoA1 and ApoE4 NLPs and developing this system as a supporting scaffold for future structural studies of membrane proteins crystalized in a native lipid environment.
Collapse
Affiliation(s)
- M.L. Shelby
- Biosciences and Biotechnology Division, Lawrence Livermore National Laboratory, Livermore, CA, USA
| | - D. Gilbile
- Department of Chemical Engineering, University of California at Davis, Davis, CA, USA
| | - T.D. Grant
- Department of Structural Biology, Jacobs School of Medicine and Biomedical Sciences, SUNY University at Buffalo, Buffalo, NY, USA
- Hauptman-Woodward Medical Research Institute, Buffalo, NY, USA
| | - W.J. Bauer
- Hauptman-Woodward Medical Research Institute, Buffalo, NY, USA
| | - B. Segelke
- Biosciences and Biotechnology Division, Lawrence Livermore National Laboratory, Livermore, CA, USA
| | - W. He
- Biosciences and Biotechnology Division, Lawrence Livermore National Laboratory, Livermore, CA, USA
| | - A.C. Evans
- Biosciences and Biotechnology Division, Lawrence Livermore National Laboratory, Livermore, CA, USA
- Department of Chemical Engineering, University of California at Davis, Davis, CA, USA
| | - N. Crespo
- Department of Structural Biology, Jacobs School of Medicine and Biomedical Sciences, SUNY University at Buffalo, Buffalo, NY, USA
- Hauptman-Woodward Medical Research Institute, Buffalo, NY, USA
| | - P. Fischer
- Center for Free-Electron Laser Science, Hamburg, Germany
| | - T. Pakendorf
- Center for Free-Electron Laser Science, Hamburg, Germany
| | - V. Hennicke
- Center for Free-Electron Laser Science, Hamburg, Germany
| | - M.S. Hunter
- Linac Coherent Light Source, SLAC National Accelerator Laboratory, Menlo Park, California, USA
| | - A. Batyuk
- Linac Coherent Light Source, SLAC National Accelerator Laboratory, Menlo Park, California, USA
| | - M. Barthelmess
- Center for Free-Electron Laser Science, Hamburg, Germany
| | - A. Meents
- Center for Free-Electron Laser Science, Hamburg, Germany
| | - T.L. Kuhl
- Department of Chemical Engineering, University of California at Davis, Davis, CA, USA
| | - M. Frank
- Biosciences and Biotechnology Division, Lawrence Livermore National Laboratory, Livermore, CA, USA
- Department of Chemical Engineering, University of California at Davis, Davis, CA, USA
- Correspondence: ; Tel: +1-925-423-7687 or ; Tel: 1-925-423-5068
| | - M.A. Coleman
- Biosciences and Biotechnology Division, Lawrence Livermore National Laboratory, Livermore, CA, USA
- Department of Chemical Engineering, University of California at Davis, Davis, CA, USA
- Correspondence: ; Tel: +1-925-423-7687 or ; Tel: 1-925-423-5068
| |
Collapse
|
2
|
Shelby ML, Gilbile D, Grant TD, Seuring C, Segelke BW, He W, Evans AC, Pakendorf T, Fischer P, Hunter MS, Batyuk A, Barthelmess M, Meents A, Coleman MA, Kuhl TL, Frank M. A fixed-target platform for serial femtosecond crystallography in a hydrated environment. IUCRJ 2020; 7:30-41. [PMID: 31949902 PMCID: PMC6949605 DOI: 10.1107/s2052252519014003] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Accepted: 10/15/2019] [Indexed: 05/19/2023]
Abstract
For serial femtosecond crystallography at X-ray free-electron lasers, which entails collection of single-pulse diffraction patterns from a constantly refreshed supply of microcrystalline sample, delivery of the sample into the X-ray beam path while maintaining low background remains a technical challenge for some experiments, especially where this methodology is applied to relatively low-ordered samples or those difficult to purify and crystallize in large quantities. This work demonstrates a scheme to encapsulate biological samples using polymer thin films and graphene to maintain sample hydration in vacuum conditions. The encapsulated sample is delivered into the X-ray beam on fixed targets for rapid scanning using the Roadrunner fixed-target system towards a long-term goal of low-background measurements on weakly diffracting samples. As a proof of principle, we used microcrystals of the 24 kDa rapid encystment protein (REP24) to provide a benchmark for polymer/graphene sandwich performance. The REP24 microcrystal unit cell obtained from our sandwiched in-vacuum sample was consistent with previously established unit-cell parameters and with those measured by us without encapsulation in humidified helium, indicating that the platform is robust against evaporative losses. While significant scattering from water was observed because of the sample-deposition method, the polymer/graphene sandwich itself was shown to contribute minimally to background scattering.
Collapse
Affiliation(s)
- M. L. Shelby
- Lawrence Livermore National Laboratory, Livermore, CA 94550, USA
| | - D. Gilbile
- University of California at Davis, California, USA
| | - T. D. Grant
- Department of Structural Biology, Jacobs School of Medicine and Biomedical Sciences, Hauptman-Woodward Institute, SUNY University at Buffalo, Buffalo, New York, USA
| | - C. Seuring
- Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron, Hamburg, Germany
| | - B. W. Segelke
- Lawrence Livermore National Laboratory, Livermore, CA 94550, USA
| | - W. He
- Lawrence Livermore National Laboratory, Livermore, CA 94550, USA
| | - A. C. Evans
- Lawrence Livermore National Laboratory, Livermore, CA 94550, USA
- University of California at Davis, California, USA
| | - T. Pakendorf
- Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron, Hamburg, Germany
| | - P. Fischer
- Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron, Hamburg, Germany
| | - M. S. Hunter
- Linac Coherent Light Source, SLAC National Accelerator Laboratory, Menlo Park, California, USA
| | - A. Batyuk
- Linac Coherent Light Source, SLAC National Accelerator Laboratory, Menlo Park, California, USA
| | - M. Barthelmess
- Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron, Hamburg, Germany
| | - A. Meents
- Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron, Hamburg, Germany
| | - M. A. Coleman
- Lawrence Livermore National Laboratory, Livermore, CA 94550, USA
- University of California at Davis, California, USA
| | - T. L. Kuhl
- University of California at Davis, California, USA
| | - M. Frank
- Lawrence Livermore National Laboratory, Livermore, CA 94550, USA
- University of California at Davis, California, USA
| |
Collapse
|
3
|
Abstract
X-ray free-electron lasers provide femtosecond-duration pulses of hard X-rays with a peak brightness approximately one billion times greater than is available at synchrotron radiation facilities. One motivation for the development of such X-ray sources was the proposal to obtain structures of macromolecules, macromolecular complexes, and virus particles, without the need for crystallization, through diffraction measurements of single noncrystalline objects. Initial explorations of this idea and of outrunning radiation damage with femtosecond pulses led to the development of serial crystallography and the ability to obtain high-resolution structures of small crystals without the need for cryogenic cooling. This technique allows the understanding of conformational dynamics and enzymatics and the resolution of intermediate states in reactions over timescales of 100 fs to minutes. The promise of more photons per atom recorded in a diffraction pattern than electrons per atom contributing to an electron micrograph may enable diffraction measurements of single molecules, although challenges remain.
Collapse
Affiliation(s)
- Henry N. Chapman
- Center for Free-Electron Laser Science, DESY, 22607 Hamburg, Germany
- Department of Physics, University of Hamburg, 22761 Hamburg, Germany
- Centre for Ultrafast Imaging, University of Hamburg, 22761 Hamburg, Germany
| |
Collapse
|
4
|
Martiel I, Müller-Werkmeister HM, Cohen AE. Strategies for sample delivery for femtosecond crystallography. Acta Crystallogr D Struct Biol 2019; 75:160-177. [PMID: 30821705 PMCID: PMC6400256 DOI: 10.1107/s2059798318017953] [Citation(s) in RCA: 65] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2018] [Accepted: 12/19/2018] [Indexed: 11/11/2022] Open
Abstract
Highly efficient data-collection methods are required for successful macromolecular crystallography (MX) experiments at X-ray free-electron lasers (XFELs). XFEL beamtime is scarce, and the high peak brightness of each XFEL pulse destroys the exposed crystal volume. It is therefore necessary to combine diffraction images from a large number of crystals (hundreds to hundreds of thousands) to obtain a final data set, bringing about sample-refreshment challenges that have previously been unknown to the MX synchrotron community. In view of this experimental complexity, a number of sample delivery methods have emerged, each with specific requirements, drawbacks and advantages. To provide useful selection criteria for future experiments, this review summarizes the currently available sample delivery methods, emphasising the basic principles and the specific sample requirements. Two main approaches to sample delivery are first covered: (i) injector methods with liquid or viscous media and (ii) fixed-target methods using large crystals or using microcrystals inside multi-crystal holders or chips. Additionally, hybrid methods such as acoustic droplet ejection and crystal extraction are covered, which combine the advantages of both fixed-target and injector approaches.
Collapse
Affiliation(s)
- Isabelle Martiel
- Swiss Light Source, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Henrike M. Müller-Werkmeister
- Institute of Chemistry – Physical Chemistry, University of Potsdam, Karl-Liebknecht-Strasse 24-25, 14476 Potsdam-Golm, Germany
| | - Aina E. Cohen
- Stanford Synchrotron Radiation Lightsource, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
| |
Collapse
|
5
|
Casadei CM, Nass K, Barty A, Hunter MS, Padeste C, Tsai CJ, Boutet S, Messerschmidt M, Sala L, Williams GJ, Ozerov D, Coleman M, Li XD, Frank M, Pedrini B. Structure-factor amplitude reconstruction from serial femtosecond crystallography of two-dimensional membrane-protein crystals. IUCRJ 2019; 6:34-45. [PMID: 30713701 PMCID: PMC6327180 DOI: 10.1107/s2052252518014641] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/06/2018] [Accepted: 10/16/2018] [Indexed: 06/09/2023]
Abstract
Serial femtosecond crystallography of two-dimensional membrane-protein crystals at X-ray free-electron lasers has the potential to address the dynamics of functionally relevant large-scale motions, which can be sterically hindered in three-dimensional crystals and suppressed in cryocooled samples. In previous work, diffraction data limited to a two-dimensional reciprocal-space slice were evaluated and it was demonstrated that the low intensity of the diffraction signal can be overcome by collecting highly redundant data, thus enhancing the achievable resolution. Here, the application of a newly developed method to analyze diffraction data covering three reciprocal-space dimensions, extracting the reciprocal-space map of the structure-factor amplitudes, is presented. Despite the low resolution and completeness of the data set, it is shown by molecular replacement that the reconstructed amplitudes carry meaningful structural information. Therefore, it appears that these intrinsic limitations in resolution and completeness from two-dimensional crystal diffraction may be overcome by collecting highly redundant data along the three reciprocal-space axes, thus allowing the measurement of large-scale dynamics in pump-probe experiments.
Collapse
Affiliation(s)
| | - Karol Nass
- Paul Scherrer Institute, 5232 Villigen PSI, Switzerland
| | - Anton Barty
- Center for Free-Electron Laser Science, DESY, Notkestrasse 85, 22607 Hamburg, Germany
| | - Mark S. Hunter
- Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550, USA
| | | | - Ching-Ju Tsai
- Paul Scherrer Institute, 5232 Villigen PSI, Switzerland
| | - Sébastien Boutet
- Linac Coherent Light Source, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
| | - Marc Messerschmidt
- Linac Coherent Light Source, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
- National Science Foundation BioXFEL Science and Technology Center, 700 Ellicott Street, Buffalo, NY 14203, USA
| | - Leonardo Sala
- Paul Scherrer Institute, 5232 Villigen PSI, Switzerland
| | - Garth J. Williams
- Linac Coherent Light Source, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
- NSLS-II, Brookhaven National Laboratory, PO Box 5000, Upton, NY 11973, USA
| | - Dmitry Ozerov
- Paul Scherrer Institute, 5232 Villigen PSI, Switzerland
| | - Matthew Coleman
- Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550, USA
| | - Xiao-Dan Li
- Paul Scherrer Institute, 5232 Villigen PSI, Switzerland
| | - Matthias Frank
- Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550, USA
| | - Bill Pedrini
- Paul Scherrer Institute, 5232 Villigen PSI, Switzerland
| |
Collapse
|
6
|
Wu ZQ, Liu YM, Liu C, Chen JJ, Chen LL, Zhang TD, Zhou RB, Yang CQ, Shang P, Yin DC. A first attempt investigation on crystallization screening and crystal quality of lysozyme under different simulated gravities in a large-gradient magnetic field. CrystEngComm 2019. [DOI: 10.1039/c9ce00730j] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
A magnetic field has been proved useful in protein crystallization in that it can help to improve the crystal quality, which is essential for high-resolution diffraction using crystallography.
Collapse
|
7
|
Arnal RD, Zhao Y, Mitra AK, Spence JCH, Millane RP. The phase problem for two-dimensional crystals. II. Simulations. Acta Crystallogr A Found Adv 2018; 74:537-544. [DOI: 10.1107/s2053273318008707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2018] [Accepted: 06/13/2018] [Indexed: 11/10/2022] Open
Abstract
Phasing of diffraction data from two-dimensional crystals using only minimal molecular envelope information is investigated by simulation. Two-dimensional crystals are an attractive target for studying membrane proteins using X-ray free-electron lasers, particularly for dynamic studies at room temperature. Simulations using an iterative projection algorithm show that phasing is feasible with fairly minimal molecular envelope information, supporting recent uniqueness results for this problem [Arnal & Millane (2017).Acta Cryst.A73, 438–448]. The effects of noise and likely requirements for structure determination using X-ray free-electron laser sources are investigated.
Collapse
|