Yang SY, Sencadas V, You SS, Jia NZX, Srinivasan SS, Huang HW, Ahmed AE, Liang JY, Traverso G. Powering Implantable and Ingestible Electronics. ADVANCED FUNCTIONAL MATERIALS 2021; 31:2009289. [PMID: 34720792 PMCID: PMC8553224 DOI: 10.1002/adfm.202009289] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Indexed: 05/28/2023]
Abstract
Implantable and ingestible biomedical electronic devices can be useful tools for detecting physiological and pathophysiological signals, and providing treatments that cannot be done externally. However, one major challenge in the development of these devices is the limited lifetime of their power sources. The state-of-the-art of powering technologies for implantable and ingestible electronics is reviewed here. The structure and power requirements of implantable and ingestible biomedical electronics are described to guide the development of powering technologies. These powering technologies include novel batteries that can be used as both power sources and for energy storage, devices that can harvest energy from the human body, and devices that can receive and operate with energy transferred from exogenous sources. Furthermore, potential sources of mechanical, chemical, and electromagnetic energy present around common target locations of implantable and ingestible electronics are thoroughly analyzed; energy harvesting and transfer methods befitting each energy source are also discussed. Developing power sources that are safe, compact, and have high volumetric energy densities is essential for realizing long-term in-body biomedical electronics and for enabling a new era of personalized healthcare.
Collapse
Affiliation(s)
- So-Yoon Yang
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Vitor Sencadas
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; School of Mechanical, Materials & Mechatronics Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Siheng Sean You
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Neil Zi-Xun Jia
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Shriya Sruthi Srinivasan
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Hen-Wei Huang
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Abdelsalam Elrefaey Ahmed
- Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Jia Ying Liang
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Giovanni Traverso
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| |
Collapse
|
2
|
Li M, Slepian MJ, Barth EJ. Bond Graph Modeling of Mechanical Circulatory Support Device-Cardiovascular System Interactions. J Biomech Eng 2020; 142:084501. [PMID: 31891373 DOI: 10.1115/1.4045812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Indexed: 07/25/2024]
Abstract
Though mechanical circulatory support (MCS) devices, such as ventricular assist devices and total artificial hearts (TAH), provide heart failure patients with bridges to heart transplantation or are alternatives to transplantation, device performance, and corresponding control strategies are often difficult to evaluate. Difficulties arise due to the complex interaction of multiple domains-i.e., biological, hydraulic, hemodynamics, electromechanical, system dynamics, and controls. In an attempt to organize, integrate and clarify these interactions, a technique often used in hydraulic pump design and robotics, called "bond graph modeling," is applied to describe the performance and functionality of MCS devices and the interaction between the cardiovascular (CV) system and the MCS device. This technical brief demonstrates the advantages of this tool in formulating a model for the systemic circulation interacting with the left side of a TAH, adopting the fundamental structure of either a hydraulic mechanism (i.e., AbioCor/Carmat) or a pneumatic mechanism (i.e., SynCardia), combined with a systemic circulation loop. The model captures the dynamics of the membrane, the hydraulic source or pneumatic source, and the systemic circulation. This multidisciplinary cross-pollination of an analytical tool from the field of dynamic systems may provide important insight to further aid and improve the design and control of future MCS systems.
Collapse
Affiliation(s)
- Mengtang Li
- Department of Mechanical Engineering, Vanderbilt University, 2301 Vanderbilt Place, Nashville, TN 37235
| | - Marvin J Slepian
- Department of Biomedical Engineering, Sarver Heart Center University of Arizona, 1501 N Campbell Avenue, Tucson, AZ 85724; Department of Medicine, Sarver Heart Center University of Arizona,1501 N Campbell Avenue, Tucson, AZ 85724
| | - Eric J Barth
- Department of Mechanical Engineering, Vanderbilt University, 2301 Vanderbilt Place, Nashville, TN 37235
| |
Collapse
|
3
|
|
4
|
Huang H, Yang M, Lu C, Xu L, Zhuang X, Meng F. A numerical method to enhance the performance of a cam-type electric motor-driven left ventricular assist device. Artif Organs 2013; 37:875-83. [PMID: 23634991 DOI: 10.1111/aor.12077] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Pulsatile left ventricular assist devices (LVADs) driven by electric motors have been widely accepted as a treatment of heart failure. Performance enhancement with computer assistance for this kind of LVAD has seldom been reported. In this article, a numerical method is proposed to assist the design of a cam-type pump. The method requires an integrated model of an LVAD system, consisting of a motor, a transmission mechanism, and a cardiovascular circulation. Performance indices, that is, outlet pressure, outlet flow, and pump efficiency, were used to select the best cam profile from six candidates. A prototype pump connected to a mock circulatory loop (MCL) was used to calibrate the friction coefficient of the cam groove and preliminarily evaluate modeling accuracy. In vitro experiments show that the mean outlet pressure and flow can be predicted with high accuracy by the model, and gross geometries of the measurements can also be reproduced. Simulation results demonstrate that as the total peripheral resistance (TPR) is fixed at 1.1 mm Hg.s/mL, the two-cycle 2/3-rise profile is the best. Compared with other profiles, the maximum increases of pressure and flow indices are 75 and 76%, respectively, and the maximum efficiency increase is over 51%. For different TPRs (0.5∼1.5 mm Hg.s/mL) and operation intervals (0.1∼0.4 s) in counterpulsation, the conclusion is also acceptable.
Collapse
Affiliation(s)
- Huan Huang
- Department of Instrument Science and Engineering, Shanghai Jiaotong University, Shanghai, China
| | | | | | | | | | | |
Collapse
|
5
|
Shi Y, Shi Y, Korakianitis T. Physiological control of an in-series connected pulsatile VAD: numerical simulation study. Comput Methods Biomech Biomed Engin 2011; 14:995-1007. [PMID: 21161796 DOI: 10.1080/10255842.2010.504030] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
This paper investigates ventricular assist device (VAD)-assisted cardiovascular dynamics under proportion-integration-differentiation (PID) feedback control. Previously, we have studied the cardiovascular responses under the support of an in-series connected reciprocating-valve VAD through numerical simulation, and no feedback control was applied in the VAD. In this research, we explore the contribution of the VAD control on the circulatory dynamics assisted by the reciprocating-valve VAD, in response to the changing physiological conditions. The classical PID control algorithm is implemented to regulate the VAD stroke beat-to-beat, based on the error signal between the expected and the realistic mean aortic pressures. Simulation results show that under the PID VAD control, physiological variables such as left atrial, ventricular and systemic arterial pressures, cardiac output and ventricular volumes are satisfactorily maintained in the physiological ranges. With the online PID feedback control, operation of the reciprocating-valve VAD can be satisfactorily regulated to accommodate metabolic requirements under various physiological conditions including normal resting and exercise situations.
Collapse
Affiliation(s)
- Yubing Shi
- Medical Physics Unit, Department of Cardiovascular Science, Faculty of Medicine, Dentistry and Health, University of Sheffield, Sheffield, UK.
| | | | | |
Collapse
|
6
|
Shi Y, Brown AG, Lawford PV, Arndt A, Nuesser P, Hose DR. Computational modelling and evaluation of cardiovascular response under pulsatile impeller pump support. Interface Focus 2011; 1:320-37. [PMID: 22670203 DOI: 10.1098/rsfs.2010.0039] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2010] [Accepted: 02/04/2011] [Indexed: 11/12/2022] Open
Abstract
This study presents a numerical simulation of cardiovascular response in the heart failure condition under the support of a Berlin Heart INCOR impeller pump-type ventricular assist device (VAD). The model is implemented using the CellML modelling language. To investigate the potential of using the Berlin Heart INCOR impeller pump to produce physiologically meaningful arterial pulse pressure within the various physiological constraints, a series of VAD-assisted cardiovascular cases are studied, in which the pulsation ratio and the phase shift of the VAD motion profile are systematically changed to observe the cardiovascular responses in each of the studied cases. An optimization process is proposed, including the introduction of a cost function to balance the importance of the characteristic cardiovascular variables. Based on this cost function it is found that a pulsation ratio of 0.35 combined with a phase shift of 200° produces the optimal cardiovascular response, giving rise to a maximal arterial pulse pressure of 12.6 mm Hg without inducing regurgitant pump flow while keeping other characteristic cardiovascular variables within appropriate physiological ranges.
Collapse
Affiliation(s)
- Yubing Shi
- Medical Physics Group, Department of Cardiovascular Science, Faculty of Medicine, Dentistry and Health , University of Sheffield , Sheffield S10 2RX , UK
| | | | | | | | | | | |
Collapse
|
7
|
Lee JJ, Kim WE, Choi J, Park JW, Chung J, Nam K, Park SK, Son HS, Sun K, Min BG. Robust Motor Speed Control under Time Varying Loads in Moving Actuator Type artificial Heart (AnyHeart). Int J Artif Organs 2004; 27:787-95. [PMID: 15521219 DOI: 10.1177/039139880402700909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The Moving Actuator type artificial heart(AnyHeart) as well as many other artificial hearts uses a motor as its power source. For controllability of control parameters such as pump rate, pump output, blood pressure profile and flow form, the precise motor speed control is important. However, because the implantable device has limited carrying capacity of hardware components in size and number, applying diverse motor control methods are not possible. In addition, the existing PI (Proportional-Integral) motor controller does not show satisfactory performance. A new controller that is sufficiently robust for the changes of load and physical system parameters has been designed and tested. The robust speed controller is based on the sliding mode control method that is applicable to a system of which the ranges of uncertainty in physical parameters are known. In a mock circulation system test, the actual speed showed good tracking characteristics in respect to the reference speed. Fast follow-up characteristics were also observed under high afterload and speed conditions. The speed error, current and power consumption were reduced by about 40%. The proposed control technique overcomes the limitations of the PI controller, and makes important improvements in both performance and stability.
Collapse
Affiliation(s)
- J J Lee
- Interdisciplinary Program in Medical and Biological Engineering Major, Graduate School Department of Biomedical Engineering, Seoul National University, Seoul, Korea
| | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Giridharan GA, Pantalos GM, Gillars KJ, Koenig SC, Skliar M. Physiologic Control of Rotary Blood Pumps: An In Vitro Study. ASAIO J 2004; 50:403-9. [PMID: 15497377 DOI: 10.1097/01.mat.0000136652.78197.58] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Rotary blood pumps (RBPs) are currently being used as a bridge to transplantation as well as for myocardial recovery and destination therapy for patients with heart failure. Physiologic control systems for RBPs that can automatically and autonomously adjust the pump flow to match the physiologic requirement of the patient are needed to reduce human intervention and error, while improving the quality of life. Physiologic control systems for RBPs should ensure adequate perfusion while avoiding inflow occlusion via left ventricular (LV) suction for varying clinical and physical activity conditions. For RBPs used as left ventricular assist devices (LVADs), we hypothesize that maintaining a constant average pressure difference between the pulmonary vein and the aorta (deltaPa) would give rise to a physiologically adequate perfusion while avoiding LV suction. Using a mock circulatory system, we tested the performance of the control strategy of maintaining a constant average deltaPa and compared it with the results obtained when a constant average pump pressure head (deltaP) and constant rpm are maintained. The comparison was made for normal, failing, and asystolic left heart during rest and at light exercise. The deltaPa was maintained at 95 +/- 1 mm Hg for all the scenarios. The results indicate that the deltaPa control strategy maintained or restored the total flow rate to that of the physiologically normal heart during rest (3.8 L/m) and light exercise (5.4 L/m) conditions. The deltaPa approach adapted to changing exercise and clinical conditions better than the constant rpm and constant deltaP control strategies. The deltaPa control strategy requires the implantation of two pressure sensors, which may not be clinically feasible. Sensorless RBP control using the deltaPa algorithm, which can eliminate the failure prone pressure sensors, is being currently investigated.
Collapse
|
9
|
Giridharan GA, Skliar M. Control strategy for maintaining physiological perfusion with rotary blood pumps. Artif Organs 2003; 27:639-48. [PMID: 12823419 DOI: 10.1046/j.1525-1594.2003.07089.x] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
We present arguments and simulation results in favor of a novel strategy for control of rotary blood pumps. We suggest that physiological perfusion is achieved when the blood pump is controlled to maintain an average reference differential pressure. In the case of rotary left ventricular assist devices, our simulations show that maintaining a constant average pressure difference between the left ventricle and aorta results in physiological perfusion over a wide range of physical activities and clinical cardiac conditions. We simulated rest, light, and strenuous exercise conditions, corresponding to cardiac demands of 4.92, 7.98, and 14.62 L/min, respectively. For different exercise levels, the clinical conditions ranged from normal to failing to asystolic heart. By maintaining a constant pressure difference of 75 mm Hg between the left ventricle and aorta, with either an axial or a centrifugal blood pump, a total cardiac output close to the physiological cardiac demand was achieved, irrespective of the heart condition. The simulations of the transitions between different levels of exercise indicate that with the same reference differential pressure, the proposed approach leads to rapid adaptation of the total cardiac output to physiological levels, while avoiding suction. Comparison with the traditional control strategy of maintaining a reference rotational speed (rpm) of the pump indicates that though the traditional approach has some degree of adaptability, it is only adequate over a narrow range of cardiac demand and clinical conditions of the patient. Our results indicate that the proposed approach is superior to the alternatives in providing an adequate and autonomous adaptation of the total cardiac output over a broad range of exercise conditions (expected when an assist device is used as a destination therapy) and clinical statuses of the native heart (such as further deterioration or recovery of cardiac function), while having the potential to improve the quality of life of patients by reducing the need for monitoring and frequent human intervention. The proposed approach can be clinically implemented using simple controllers, and requires the implantation of two pressure sensors, or estimation of the pressure difference based on other available measurements.
Collapse
Affiliation(s)
- Guruprasad A Giridharan
- Department of Chemical and Fuels Engineering, University of Utah, Salt Lake City, UT 84112, USA
| | | |
Collapse
|
10
|
Jastremski M, Jastremski C, Shepherd M, Friedman V, Porembka D, Smith R, Gonzales E, Swedlow D, Belzberg H, Crass R. A model for technology assessment as applied to closed loop infusion systems. Technology Assessment Task Force of the Society of Critical Care Medicine. Crit Care Med 1995; 23:1745-55. [PMID: 7587242 DOI: 10.1097/00003246-199510000-00021] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
OBJECTIVES To test a model for the assessment of critical care technology on closed loop infusion control, a technology that is in its early stages of development and testing on human subjects. DATA SOURCES A computer-assisted search of the English language literature and reviews of the gathered data by experts in the field of closed loop infusion control systems. STUDY SELECTION Studies relating to closed loop infusion control that addressed one or more of the questions contained in our technology assessment template were analyzed. Study design was not a factor in article selection. However, the lack of well-designed clinical outcome studies was an important factor in determining our conclusions. DATA EXTRACTION A focus person summarized the data from the selected studies that related to each of the assessment questions. The preliminary data summary developed by the focus person was further analyzed and refined by the task force. Experts in closed loop systems were then added to the group to review the summary provided by the task force. These experts' comments were considered by the task force and this final consensus report was developed. DATA SYNTHESIS Closed loop system control is a technological concept that may be applicable to several aspects of critical care practice. This is a technology in the early stages of evolution and much more research and data are needed before its introduction into usual clinical practice. Furthermore, each specific application and each device for each application (e.g., nitroprusside infusion, ventilator adjustment), although based on the same technological concept, are sufficiently different in terms of hardware and computer algorithms to require independent validation studies. CONCLUSIONS Closed loop infusion systems may have a role in critical care practice. However, for most applications, further development is required to move this technology from the innovation phase to the point where it can be evaluated so that its role in critical car practice can be defined. Each application of closed loop infusion systems must be independently validated by appropriately designed research studies. Users should be provided with the clinical parameters driving each closed loop system so that they can ensure that it agrees with their opinion of acceptable medical practice. Clinical researchers and leaders in industry should collaborate to perform the scientifically valid, outcome-based research that is necessary to evaluate the effect of this new technology. The original model we developed for technology assessment required the addition of several more questions to produce a complete analysis of an emerging technology. An emerging technology should be systematically assessed (using a model such as the model developed by the Society of Critical Care Medicine), before its introduction into clinical practice in order to provide a focus for human outcome validation trials and to minimize the possibility of widespread use of an unproven technology.
Collapse
Affiliation(s)
- M Jastremski
- Hamilton Critical Care and Emergency Consultants, Syracuse, NY, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|