Hoffmeister BK, Gray AJ, Sharp PC, Fairbanks LC, Huang J. Ultrasonic Bone Assessment Using the Backscatter Amplitude Decay Constant. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:2412-2423. [PMID: 32553693 DOI: 10.1016/j.ultrasmedbio.2020.04.029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2019] [Revised: 03/29/2020] [Accepted: 04/26/2020] [Indexed: 06/11/2023]
Abstract
Ultrasonic backscatter techniques are being developed to detect changes in bone caused by osteoporosis. The present study introduces a new technique that measures the exponential decay in the amplitude of the backscatter signal quantified by a parameter called the backscatter amplitude decay constant (BADC). Measurements were performed on 54 specimens of cancellous bone from 14 human femurs using a 3.5-MHz transducer. Six methods were tested to determine BADC. The recommended method measures the time slope of the natural log of the rectified signal. Measured values of BADC ranged from approximately 0.1 μs-1 to 0.6 μs-1. Moderate to strong correlations (Spearman's ρ >0.7) were found between BADC and the density and microstructural characteristics of the specimens determined using X-ray microcomputed tomography. The results of this study suggest that BADC may be able to detect changes in the density and microstructure of cancellous bone caused by osteoporosis and other diseases.
Collapse
Affiliation(s)
| | - Aubrey J Gray
- Department of Physics, Rhodes College, Memphis, Tennessee, USA
| | - Phoebe C Sharp
- Department of Physics, Rhodes College, Memphis, Tennessee, USA
| | | | - Jinsong Huang
- University of Tennessee Health Science Center, Memphis, Tennessee, USA
| |
Collapse
|
2
|
Musu D, Cadeddu Dessalvi C, Shemesh H, Frenda MG, Mercuro G, Cotti E. Ultrasound examination for the detection of simulated periapical bone lesions in bovine mandibles: an ex vivo study. Int Endod J 2020; 53:1289-1298. [PMID: 32531801 DOI: 10.1111/iej.13346] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2020] [Accepted: 06/04/2020] [Indexed: 11/28/2022]
Abstract
AIM To evaluate the accuracy of ultrasound examination (USE) for the detection of artificial bone defects in bovine mandibles in the absence of complete erosion of the cortical bone plate and to determine the minimum cortical thickness that constitutes a barrier for ultrasound waves. METHODOLOGY Sixty bovine mandibular anatomical blocks were harvested and uniformly distributed amongst six experimental groups. The negative control consisted of blocks with no intra-bony defects, whereas the positive control consisted of blocks with an artificial lesion of 2 mm diameter that perforated the buccal cortical bone plate. Two experimental groups comprised blocks with small (2 mm) and large (5 mm) artificial defects created under a cortical plate thinned to varying thicknesses. Two additional groups had small (2 mm) and large (5 mm) artificial defects that did not involve the cortical plate. After USE, the scans were saved and submitted to three blinded examiners. Sensitivity, specificity, predictive values and receiver-operating characteristics (ROC) were analysed. The significance of the findings (P < 0.05) was appraised using the chi-square statistics with the Yates correction, whilst the intra- and inter-examiner agreements were evaluated through Kappa statistics. RESULTS USE was associated with high sensitivity (97.3%) and negative predictive value (89%), and a perfect score for specificity and positive predictive value. The ROC curve analysis revealed an accuracy of 97.8%. The k-values were 0.86 and 0.89 for the first and second examinations, respectively, demonstrating very high inter-observer agreement. The intra-observer agreement was also high (k-value = 0.92). A significant correlation between the echographic diagnosis and the presence or absence of artificial intraosseous lesions in the anatomical blocks of bovine mandibles was observed (P < 0.0001). CONCLUSIONS USE was highly accurate and reliable for the detection of artificial lesions within bovine mandibles, regardless of the thickness or presence of the cortical plate.
Collapse
Affiliation(s)
- D Musu
- Department of Conservative Dentistry and Endodontics, University of Cagliari, Cagliari, Italy
| | - C Cadeddu Dessalvi
- Department of Medical Sciences and Public Health, University of Cagliari, Cagliari, Italy
| | - H Shemesh
- Department of Endodontology, Academic Centre for Dentistry Amsterdam (ACTA), Amsterdam, Netherlands
| | - M G Frenda
- Department of Conservative Dentistry and Endodontics, University of Cagliari, Cagliari, Italy
| | - G Mercuro
- Department of Medical Sciences and Public Health, University of Cagliari, Cagliari, Italy
| | - E Cotti
- Department of Conservative Dentistry and Endodontics, University of Cagliari, Cagliari, Italy
| |
Collapse
|
3
|
Wear KA. Mechanisms of Interaction of Ultrasound With Cancellous Bone: A Review. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:454-482. [PMID: 31634127 PMCID: PMC7050438 DOI: 10.1109/tuffc.2019.2947755] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Ultrasound is now a clinically accepted modality in the management of osteoporosis. The most common commercial clinical devices assess fracture risk from measurements of attenuation and sound speed in cancellous bone. This review discusses fundamental mechanisms underlying the interaction between ultrasound and cancellous bone. Because of its two-phase structure (mineralized trabecular network embedded in soft tissue-marrow), its anisotropy, and its inhomogeneity, cancellous bone is more difficult to characterize than most soft tissues. Experimental data for the dependencies of attenuation, sound speed, dispersion, and scattering on ultrasound frequency, bone mineral density, composition, microstructure, and mechanical properties are presented. The relative roles of absorption, scattering, and phase cancellation in determining attenuation measurements in vitro and in vivo are delineated. Common speed of sound metrics, which entail measurements of transit times of pulse leading edges (to avoid multipath interference), are greatly influenced by attenuation, dispersion, and system properties, including center frequency and bandwidth. However, a theoretical model has been shown to be effective for correction for these confounding factors in vitro and in vivo. Theoretical and phantom models are presented to elucidate why cancellous bone exhibits negative dispersion, unlike soft tissue, which exhibits positive dispersion. Signal processing methods are presented for separating "fast" and "slow" waves (predicted by poroelasticity theory and supported in cancellous bone) even when the two waves overlap in time and frequency domains. Models to explain dependencies of scattering on frequency and mean trabecular thickness are presented and compared with measurements. Anisotropy, the effect of the fluid filler medium (marrow in vivo or water in vitro), phantoms, computational modeling of ultrasound propagation, acoustic microscopy, and nonlinear properties in cancellous bone are also discussed.
Collapse
|
4
|
Yoon PH, An SJ, Jeong SH, Yang YJ, Hong YP. Association between Peptic Ulcer Disease and Osteoporosis: The Population-Based Longitudinal Cohort Study in Korea. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:E2777. [PMID: 31382574 PMCID: PMC6696469 DOI: 10.3390/ijerph16152777] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2019] [Revised: 07/31/2019] [Accepted: 08/01/2019] [Indexed: 01/26/2023]
Abstract
OBJECTIVES The association between peptic ulcer disease (PUD) and osteoporosis remains unclear. We investigated the association between PUD and osteoporosis by classifying individuals based on gender in a prospective study on 10,030 adults in Korea at a 12-year follow-up examination. DESIGN AND SETTING The baseline survey of the Ansung-Ansan cohort studies was conducted from May 2001 to February 2003, and 10,030 participants (5018 from the Ansung study and 5012 from the Ansan study) completed the examination. PRIMARY OUTCOME MEASURES The risk of developing osteoporosis was higher in both men and women in the PUD group than in the control group. RESULTS At the 12-year follow-up, osteoporosis had developed in 11.1% (21/189) and 29.9% (56/187) of men and women in the PUD group, respectively. Meanwhile, in the control group, 4.8% (70/1464) and 16.5% (271/1639) of men and women, respectively, were presented with osteoporosis. The incidence rates per 1000 person-years were 20.5% and 68.5% in men and women in the PUD group and 11.2% and 42.3% of men and women in the control group, respectively. The risk of developing osteoporosis was higher in both men and women in the PUD group than in the control group (men: hazard ratio [HR] = 1.72, 95% confidence interval [CI] = 1.02-2.92; women: HR = 1.62, 95% CI = 1.20-2.18). CONCLUSION The risk of developing osteoporosis was significantly higher in both men and women in the PUD group than in the control group.
Collapse
Affiliation(s)
- Phill Hoon Yoon
- Division of Gastroenterology, Department of Internal Medicine, Catholic Kwandong University International St. Mary's Hospital, Incheon 22711, Korea
| | - Sang Joon An
- Department of Neurology, Catholic Kwandong University International St. Mary's Hospital, Incheon 22711, Korea
| | - Seok-Hoo Jeong
- Division of Gastroenterology, Department of Internal Medicine, Catholic Kwandong University International St. Mary's Hospital, Incheon 22711, Korea.
| | - Yun-Jung Yang
- Institute of Biomedical Science, Catholic Kwandong University International St. Mary's Hospital, Incheon 22711, Korea.
| | - Yeon-Pyo Hong
- Department of Preventive Medicine, College of Medicine, Chung-Ang University, Seoul 06974, Korea
| |
Collapse
|
5
|
Effect of Cortical Bone Thickness on Detection of Intraosseous Lesions by Ultrasonography. Radiol Res Pract 2015; 2015:797593. [PMID: 26366296 PMCID: PMC4561116 DOI: 10.1155/2015/797593] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2015] [Revised: 08/02/2015] [Accepted: 08/04/2015] [Indexed: 11/18/2022] Open
Abstract
Background. Usefulness of ultrasound (US) in detection of intrabony lesions has been showed. A cortical bone perforation or a very thin and intact cortical bone is prerequisite for this purpose. Objective. The current in vitro study was aimed at measuring the cut-off thickness of the overlying cortical bone which allows ultrasonic assessment of bony defects. Materials and Methods. 20 bovine scapula blocks were obtained. Samples were numbered from 1 to 20. In each sample, 5 artificial lesions were made. The lesions were made in order to increase the overlying bone thickness, from 0.1 mm in the first sample to 2 mm in the last one (with 0.1 mm interval). After that, the samples underwent ultrasound examinations by two practicing radiologists. Results. All five lesions in samples numbered 1 to 11 were detected as hypoechoic area. Cortical bone thickness more than 1.1 mm resulted in a failure in the detection of central lesions. Conclusion. We can conclude that neither bony perforation nor very thin cortical bones are needed to consider US to be an effective imaging technique in the evaluation of bony lesion.
Collapse
|
6
|
Cotton R, Pearce C, Young P, Kota N, Leung A, Bagchi A, Qidwai S. Development of a geometrically accurate and adaptable finite element head model for impact simulation: the Naval Research Laboratory–Simpleware Head Model. Comput Methods Biomech Biomed Engin 2015; 19:101-13. [DOI: 10.1080/10255842.2014.994118] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
7
|
Il Lee K, Joo Choi M. Frequency-dependent attenuation and backscatter coefficients in bovine trabecular bone from 0.2 to 1.2 MHz. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 131:EL67-73. [PMID: 22280732 DOI: 10.1121/1.3671064] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
The frequency-dependent attenuation and backscatter coefficients were measured in 25 bovine femoral trabecular bone samples from 0.2 to 1.2 MHz. When the average attenuation coefficient was fitted to a nonlinear power law α(f)=α(0)+α(1)f(n), the exponent n was found to be 1.65. In contrast, the average backscatter coefficient was fitted to a power law η(f)=η(1)f(n) and the exponent n was measured as 3.25. The apparent bone density was significantly correlated with the parameter α(1) (0.2-0.7 MHz: r = 0.852, 0.6-1.2 MHz: r = 0.832) as well as the backscatter coefficient (0.5 MHz: r = 0.751, 1.0 MHz: r = 0.808).
Collapse
Affiliation(s)
- Kang Il Lee
- Department of Physics, Kangwon National University, Chuncheon 200-701, Republic of Korea
| | | |
Collapse
|
8
|
Langton CM. The 25th Anniversary of BUA for the Assessment of Osteoporosis: Time for a New Paradigm? Proc Inst Mech Eng H 2011; 225:113-25. [DOI: 10.1243/09544119jeim777] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The measurement of broadband ultrasonic attenuation (BUA) in cancellous bone at the calcaneus for the assessment of osteoporosis was first described within this journal 25 years ago. It was recognized in 2006 by Universities UK as being one of the ‘100 discoveries and developments in UK Universities that have changed the world’ over the past 50 years. In 2008, the UK's Department of Health also recognized BUA assessment of osteoporosis in a publication highlighting 11 projects that have contributed to ‘60 years of NHS research benefiting patients’. The BUA technique has been extensively clinically validated and is utilized worldwide, with at least seven commercial systems currently providing calcaneal BUA measurement. However, there is still no fundamental understanding of the dependence of BUA upon the material and structural properties of cancellous bone. This review aims to provide an ‘engineering in medicine’ perspective and proposes a new paradigm based upon phase cancellation due to variation in propagation transit time across the receive transducer face to explain the non-linear relationship between BUA and bone volume fraction in cancellous bone.
Collapse
Affiliation(s)
- C M Langton
- Physics, Faculty of Science & Technology and Institute of Health & Biomedical Innovation, Queensland University of Technology, Brisbane, Australia,
| |
Collapse
|
9
|
Wear KA. Mechanisms for attenuation in cancellous-bone-mimicking phantoms. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2008; 55:2418-25. [PMID: 19049921 PMCID: PMC6935503 DOI: 10.1109/tuffc.949] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Broadband ultrasound attenuation (BUA) in cancellous bone is useful for prediction of osteoporotic fracture risk, but its causes are not well understood. To investigate attenuation mechanisms, 9 cancellous-bone-mimicking phantoms containing nylon filaments (simulating bone trabeculae) embedded within soft-tissue-mimicking fluid (simulating marrow) were interrogated. The measurements of frequency-dependent attenuation coefficient had 3 separable components: 1) a linear (with frequency) component attributable to absorption in the soft-tissue-mimicking fluid, 2) a quasilinear (with frequency) component, which may include absorption in and longitudinal-shear mode conversion by the nylon filaments, and 3) a nonlinear (with frequency) component, which may be attributable to longitudinal-longitudinal scattering by the nylon filaments. The slope of total linear (with frequency) attenuation coefficient (sum of components #1 and #2) versus frequency was found to increase linearly with volume fraction, consistent with reported measurements on cancellous bone. Backscatter coefficient measurements in the 9 phantoms supported the claim that the nonlinear (with frequency) component of attenuation coefficient (component #3) was closely associated with longitudinal-longitudinal scattering. This work represents the first experimental separation of these 3 components of attenuation in cancellous bone-mimicking phantoms.
Collapse
Affiliation(s)
- Keith A Wear
- U.S. Food and Drug Administration, Center for Devices and Radiological Health, Silver Spring, MD, USA.
| |
Collapse
|
10
|
Sebaa N, Fellah ZA, Fellah M, Ogam E, Mitri FG, Depollier C, Lauriks W. Application of the Biot model to ultrasound in bone: inverse problem. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2008; 55:1516-23. [PMID: 18986941 DOI: 10.1109/tuffc.2008.827] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
This paper concerns the ultrasonic characterization of human cancellous bone samples by solving the inverse problem using experimentally measured signals. The inverse problem is solved numerically by the least squares method. Five parameters are inverted: porosity, tortuosity, viscous characteristic length, Young modulus, and Poisson ratio of the skeletal frame. The minimization of the discrepancy between experiment and theory is made in the time domain. The ultrasonic propagation in cancellous bone is modelled using the Biot theory modified by the Johnson-Koplik-Dashen model for viscous exchange between fluid and structure. The sensitivity of the Young modulus and the Poisson ratio of the skeletal frame is studied showing their effect on the fast and slow waveforms. The inverse problem is shown to be well posed, and its solution to be unique. Experimental results for slow and fast waves transmitted through human cancellous bone samples are given and compared with theoretical predictions.
Collapse
Affiliation(s)
- N Sebaa
- Lab. voor Akoestiek en Thermische Fysica, Katholieke Univ. Leuven, Heverlee, Belgium
| | | | | | | | | | | | | |
Collapse
|
11
|
Wear KA. Ultrasonic scattering from cancellous bone: a review. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2008; 55:1432-41. [PMID: 18986932 PMCID: PMC6935504 DOI: 10.1109/tuffc.2008.818] [Citation(s) in RCA: 65] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
This paper reviews theory, measurements, and computer simulations of scattering from cancellous bone reported by many laboratories. Three theoretical models (binary mixture, Faran cylinder, and weak scattering) for scattering from cancellous bone have demonstrated some consistency with measurements of backscatter. Backscatter is moderately correlated with bone mineral density in human calcaneus in vitro (r(2) = 0.66 - 0.68). Backscatter varies approximately as frequency cubed and trabecular thickness cubed in human calcaneus and femur in vitro. Backscatter from human calcaneus and bovine tibia exhibits substantial anisotropy. So far, backscatter has demonstrated only modest clinical utility. Computer simulation models have helped to elucidate mechanisms underlying scattering from cancellous bones.
Collapse
Affiliation(s)
- K A Wear
- Center for Devices & Radiol. Health, U.S. Food & Drug Adm., Silver Spring, MD, USA.
| |
Collapse
|
12
|
Wear KA. A method for improved standardization of in vivo calcaneal time-domain speed-of-sound measurements. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2008; 55:1473-9. [PMID: 18986936 PMCID: PMC9148199 DOI: 10.1109/tuffc.2008.822] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Although calcaneal speed of sound (SOS) is an effective predictor of osteoporotic fracture risk, clinical SOS measurements exhibit a high degree of inter-system variability. Calcaneal SOS is usually computed from time-of-flight measurements of broadband ultrasound pulses that propagate through the foot. In order to minimize the effects of multi-path interference, many investigators measure time-of-flight from markers near the leading edge of the pulse. The calcaneus is a highly attenuating, highly inhomogeneous bone that distorts propagating ultrasound pulses via frequency-dependent attenuation, reverberation, dispersion, multiple scattering, and refraction. This pulse distortion can produce errors in leading-edge transit-time marker-based SOS measurements. In this paper, an equation to predict dependence of time-domain SOS measurements on system parameters (center frequency and bandwidth), transit-time marker location, and bone properties (attenuation coefficient and thickness) is validated with through-transmission measurements in a bone-mimicking phantom and in 73 women in vivo, using a clinical bone sonometer. In order to test the utility of the formula for suppressing system dependence of SOS measurements, a wideband laboratory data acquisition system was used to make a second set of through-transmission measurements on the phantom. The compensation formula reduced system-dependent leading-edge transit-time marker-based SOS measurements in the phantom from 41 m/s to 5 m/s and reduced average transit-time marker-related SOS variability in 73 women from 40 m/s to 10 m/s. The compensation formula can be used to improve standardization in bone sonometry.
Collapse
Affiliation(s)
- K A Wear
- Center for Devices & Radiol. Health, Silver Spring, MD, USA.
| |
Collapse
|
13
|
Langton CM, Njeh CF. The measurement of broadband ultrasonic attenuation in cancellous bone--a review of the science and technology. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2008; 55:1546-54. [PMID: 18986945 DOI: 10.1109/tuffc.2008.831] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
The measurement of broadband ultrasonic attenuation (BUA) in cancellous bone at the calcaneus was first described in 1984. The assessment of osteoporosis by BUA has recently been recognized by Universities UK, within its EurekaUK book, as being one of the "100 discoveries and developments in UK Universities that have changed the world" over the past 50 years, covering the whole academic spectrum from the arts and humanities to science and technology. Indeed, BUA technique has been clinically validated and is utilized worldwide, with at least seven commercial systems providing calcaneal BUA measurement. However, a fundamental understanding of the dependence of BUA upon the material and structural properties of cancellous bone is still lacking. This review aims to provide a science- and technology-orientated perspective on the application of BUA to the medical disease of osteoporosis.
Collapse
Affiliation(s)
- C M Langton
- Fac. of Sci., Queensland Univ. of Technol., Brisbane, QLD, Brisbane, Australia.
| | | |
Collapse
|
14
|
Lee KI, Humphrey VF, Leighton TG, Yoon SW. Predictions of the modified Biot-Attenborough model for the dependence of phase velocity on porosity in cancellous bone. ULTRASONICS 2007; 46:323-30. [PMID: 17573089 DOI: 10.1016/j.ultras.2007.01.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2006] [Revised: 01/12/2007] [Accepted: 01/28/2007] [Indexed: 05/15/2023]
Abstract
The modified Biot-Attenborough (MBA) model for acoustic wave propagation in porous media has been found useful to predict wave properties in cancellous bone. The present study is aimed at applying the MBA model to predict the dependence of phase velocity on porosity in cancellous bone. The MBA model predicts a phase velocity that decreases nonlinearly with porosity. The optimum values for input parameters of the MBA model, such as compressional speed c(m) of solid bone and phase velocity parameter s(2), were determined by comparing the predictions with previously published measurements in human calcaneus and bovine cancellous bone. The value of the phase velocity parameter s(2)=1.23 was obtained by curve fitting to the experimental data for 53 human calcaneus samples only, assuming a compressional speed c(m)=2500 m/s of solid bone. The root-mean-square error (RMSE) of the curve fit was 15.3m/s. The optimized value of s(2) for all 75 cancellous bone samples including 22 bovine samples was 1.42 with a value of 55 m/s for the RMSE of the curve fit. The latter fit was obtained by using of a value of c(m)=3200 m/s. Although the MBA model relies on the empirical parameters determined from experimental data, it is expected that the model can be usefully employed as a practical tool in the field of clinical ultrasonic bone assessment.
Collapse
Affiliation(s)
- Kang Il Lee
- Department of Physics, Kangwon National University, Chuncheon 200-701, Republic of Korea
| | | | | | | |
Collapse
|
15
|
Wear KA. The dependence of time-domain speed-of-sound measurements on center frequency, bandwidth, and transit-time marker in human calcaneus in vitro. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2007; 122:636-44. [PMID: 17614520 PMCID: PMC6942661 DOI: 10.1121/1.2735811] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Time-domain speed-of-sound (SOS) measurements in calcaneus are effective predictors of osteoporotic fracture risk. High attenuation and dispersion in bone, however, produce severe distortion of transmitted pulses that leads to ambiguity of time-domain SOS measurements. An equation to predict the effects of system parameters (center frequency and bandwidth), algorithm parameters (pulse arrival-time marker), and bone properties (attenuation coefficient and thickness) on time-domain SOS estimates is derived for media with attenuation that varies linearly with frequency. The equation is validated using data from a bone-mimicking phantom and from 30 human calcaneus samples in vitro. The data suggest that the effects of dispersion are small compared with the effects of frequency-dependent attenuation. The equation can be used to retroactively compensate data. System-related variations in SOS are shown to decrease as the pulse-arrival-time marker is moved toward the pulse center. Therefore, compared with other time-domain measures of SOS, group velocity exhibits the minimum system dependence.
Collapse
Affiliation(s)
- Keith A Wear
- U.S. Food and Drug Administration, Center for Devices and Radiological Health, HFZ-140, Rockville, Maryland 20852, USA.
| |
Collapse
|
16
|
Sebaa N, Fellah ZEA, Fellah M, Ogam E, Wirgin A, Mitri FG, Depollier C, Lauriks W. Ultrasonic characterization of human cancellous bone using the Biot theory: inverse problem. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2006; 120:1816-24. [PMID: 17069280 DOI: 10.1121/1.2335420] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
This paper concerns the ultrasonic characterization of human cancellous bone samples by solving the inverse problem using experimental transmitted signals. The ultrasonic propagation in cancellous bone is modeled using the Biot theory modified by the Johnson et al. model for viscous exchange between fluid and structure. The sensitivity of the Young modulus and the Poisson ratio of the skeletal frame is studied showing their effect on the fast and slow wave forms. The inverse problem is solved numerically by the least squares method. Five parameters are inverted: the porosity, tortuosity, viscous characteristic length, Young modulus, and Poisson ratio of the skeletal frame. The minimization of the discrepancy between experiment and theory is made in the time domain. The inverse problem is shown to be well posed, and its solution to be unique. Experimental results for slow and fast waves transmitted through human cancellous bone samples are given and compared with theoretical predictions.
Collapse
Affiliation(s)
- N Sebaa
- Laboratorium voor Akoestiek en Thermische Fysica, Katholieke Universiteit Leuven, Celestijnenlaan 200 D, B-3001 Heverlee, Belgium
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Haïat G, Padilla F, Cleveland RO, Laugier P. Effects of frequency-dependent attenuation and velocity dispersion on in vitro ultrasound velocity measurements in intact human femur specimens. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2006; 53:39-51. [PMID: 16471431 DOI: 10.1109/tuffc.2006.1588390] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Numerous studies have shown that ultrasonic velocity measured in bone provides a good assessment of osteoporotic fracture risk. However, a lack of standardization of signal processing techniques used to compute the speed of sound (SOS) complicates the comparison between data obtained with different commercial devices. In this study, 38 intact femurs were tested using a through-transmission technique and SOS determined using different techniques. The resulting difference in measured SOS was determined as functions of the attenuation and the velocity dispersion. A numerical simulation was used to explain how attenuation and dispersion impact two different SOS measurements (group velocity, velocity based on the first zero crossing of the signal). A new method aimed at compensating for attenuation was devised and led to a significant reduction in the difference between SOS obtained with both signal processing techniques. A comparison between SOS and X-ray density measurements indicated that the best correlation was reached for SOS based on the first zero crossing apparently because it used a marker located in the early part of the signal and was less sensitive to multipath interference. The conclusion is that first zero crossing velocity may be preferred to group velocity for ultrasonic assessment at this potential fracture site.
Collapse
Affiliation(s)
- Guillaume Haïat
- Laboratoire d'Imagerie Paramétrique, Université Paris VI - Unité mixte de recherche 7623, Centre National de la Recherche Scientifique, 75006 Paris, France
| | | | | | | |
Collapse
|
18
|
Haïat G, Padilla F, Barkmann R, Dencks S, Moser U, Glüer CC, Laugier P. Optimal prediction of bone mineral density with ultrasonic measurements in excised human femur. Calcif Tissue Int 2005; 77:186-92. [PMID: 16151672 DOI: 10.1007/s00223-005-0057-0] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2005] [Accepted: 05/06/2005] [Indexed: 10/25/2022]
Abstract
Bone mineral density (BMD) measured with dual energy X-ray absorptiometry (DXA) techniques is the current gold standard for osteoporotic fracture risk prediction. Quantitative ultrasound (QUS) techniques in transmission measurements are, however, increasingly recognized as an alternative approach. It is feasible to select different QUS methods, one type being optimized to assess microarchitectural properties of bone structure and another to assess BMD. Broadband ultrasonic attenuation (BUA) and ultrasonic velocity (UV) measured on the proximal human femur have been shown to be both significantly correlated with BMD. However, a great diversity of algorithms has been reported to measure the time-of-flight used to derive UV values. The purpose of this study was to determine which procedure results in the optimal BMD prediction at the proximal femur from ultrasound measurements. Thirty-eight excised human femurs were measured in transmission with a pair of focused 0.5-MHz central frequency transducers. Two-dimensional scans were performed and radiofrequency (RF) signals were recorded digitally at each scan position. BUA was estimated and eight different signal processing techniques were performed to estimate UV. For each signal-processing technique UV was compared to BMD. We show that the best prediction of BMD was obtained with signal-processing techniques taking into account only the first part of the transmitted signal (r2BMD-SOS = 0.86). Moreover, we show that a linear multiple regression using both BUA and speed of sound (SOS) and applied to site-matched regions of interest improved the accuracy of BMD predictions (r2BMD-SOS/BUA = 0.95). Our results demonstrate that selecting specific signal-processing methods for QUS variables allows optimal assessment of BMD. Correlation is sufficiently high that this specific QUS method can be considered as a good surrogate of BMD.
Collapse
Affiliation(s)
- G Haïat
- Laboratoire d'Imagerie Paramétrique, Université Paris VI, UMR CNRS 7623, 15 rue de l'Ecole de Médecine, 75006 Paris, France
| | | | | | | | | | | | | |
Collapse
|
19
|
Chen PJ, Chen T. Measurements of acoustic dispersion on calcaneus using spilt spectrum processing technique. Med Eng Phys 2005; 28:187-93. [PMID: 15939657 DOI: 10.1016/j.medengphy.2005.04.018] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2004] [Revised: 02/04/2005] [Accepted: 04/08/2005] [Indexed: 11/22/2022]
Abstract
The speed of sound (SOS) has become a useful tool in osteoporosis assessment, since it represents a combination of density and compressibility of bone tissue and should provide better information on bone quality and an estimate the fracture risk. In general, the speed of sound on dispersive material, such as bone tissue, depends strongly on frequency. Therefore, a measurement of velocity dispersion magnitude (VDM) might provide more important bone structure information than measurements of bone mineral density (BMD), SOS or broadband ultrasound attenuation (BUA). To obtain the velocity dispersion magnitude requires a sequence of pulses that have a frequency that is different from that used in conventional approaches. The measurement is complicated by the fact that pulse waveform will distort as the pulses propagate through the frequency-dependent medium. Alternatively, the phase velocity and velocity dispersion measurements also can be obtained on frequency-domain processing. However, the accuracy of those techniques is affected by the 2mpi ambiguity in the phase unwrapping process in frequency domain. And the spectrum approach is highly dependent on the gating window selection in time domain signals. The time-domain split spectrum processing (SSP) technique is proposed here to measure the phase velocity and the VDM. The SSP technique is also used to measure the SOS and VDM of two commercial calcaneus phantoms. Simulation results are in good agreement with the preset parameters of a model-based signal obtained using the SSP technique. In addition, in vitro SSP measurements agree with the manufacturer's specifications for two commercial calcaneus phantoms. The negative dispersion is also found in in vivo measurements on human heel. Finally, an approach based on the time domain SSP technique has potential clinical applications for osteoporosis diagnosis.
Collapse
Affiliation(s)
- Pei-Jarn Chen
- Institute of Biomedical Engineering, National Cheng-Kung University, No. 1, Ta-Hsueh Road, Tainan 70101, Taiwan
| | | |
Collapse
|
20
|
Wear KA, Laib A, Stuber AP, Reynolds JC. Comparison of measurements of phase velocity in human calcaneus to Biot theory. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2005; 117:3319-24. [PMID: 15957798 PMCID: PMC6945752 DOI: 10.1121/1.1886388] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Biot's theory for elastic propagation in porous media has previously been shown to be useful for modeling the dependence of phase velocity on porosity in bovine cancellous bone in vitro. In the present study, Biot's theory is applied to measurements of porosity-dependent phase velocity in 53 human calcanea in vitro. Porosity was measured using microcomputed tomography for some samples (n = 23) and estimated based on bone mineral densitometry for the remaining samples (n = 30). The phase velocity at 500 kHz was measured in a water tank using a through-transmission technique. Biot's theory performed well for the prediction of the dependence of sound speed on porosity. The trend was quasilinear, but both the theory and experiment show similar slight curvature. The root mean square error (RMSE) of predicted versus measured sound speed was 15.8 m/s.
Collapse
Affiliation(s)
- Keith A Wear
- U.S. Food and Drug Administration, Center for Devices and Radiological Health, HFZ-140, 12720 Twinbrook Parkway, Rockville, Maryland 20852, USA.
| | | | | | | |
Collapse
|
21
|
Chen T, Chen PJ, Fung CS, Lin CJ, Yao WJ. Quantitative assessment of osteoporosis from the tibia shaft by ultrasound techniques. Med Eng Phys 2004; 26:141-5. [PMID: 15036181 DOI: 10.1016/j.medengphy.2003.09.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2001] [Revised: 07/31/2003] [Accepted: 09/22/2003] [Indexed: 10/26/2022]
Abstract
Bone mineral density (BMD) is used as a clinical estimate of the risk of fracture. Ultrasound provides an alternative or complement to X-ray based methods of bone densitometry for determining BMD. Among ultrasonic characteristics, the speed of sound (SOS) is a useful tool for assessment of osteoporosis because, as recently reported, it represents a combination of density and compressibility of bone tissue. Thus, it might provide better information on bone quality to estimate the fracture risk. In this paper, a dual-transducer ultrasound technique was employed to measure the mean ultrasound propagation speed of the cortical layer as well as the cancellous layer at the tibia shaft. Encouraging results from 18 outpatients showed a high correlation (r = 0.93) between measurements of BMD and those from dual energy X-ray absorptiometry (DEXA).
Collapse
Affiliation(s)
- Tainsong Chen
- Institute of Biomedical Engineering, National Cheng-Kung UniversityTainan 70101,Taiwan.
| | | | | | | | | |
Collapse
|
22
|
Lee KI, Roh HS, Yoon SW. Acoustic wave propagation in bovine cancellous bone: application of the Modified Biot-Attenborough model. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2003; 114:2284-93. [PMID: 14587625 DOI: 10.1121/1.1610450] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Acoustic wave propagation in bovine cancellous bone is experimentally and theoretically investigated in the frequency range of 0.5-1 MHz. The phase velocity, attenuation coefficient, and broadband ultrasonic attenuation (BUA) of bovine cancellous bone are measured as functions of frequency and porosity. For theoretical estimation, the Modified Biot-Attenborough (MBA) model is employed with three new phenomenological parameters: the boundary condition, phase velocity, and impedance parameters. The MBA model is based on the idealization of cancellous bone as a nonrigid porous medium with circular cylindrical pores oriented normal to the surface. It is experimentally observed that the phase velocity is approximately nondispersive and the attenuation coefficient linearly increases with frequency. The MBA model predicts a slightly negative dispersion of phase velocity linearly with frequency and the nonlinear relationships of attenuation and BUA with porosity. The experimental results are in good agreement with the theoretical results estimated with the MBA model. It is expected that the MBA model can be usefully employed in the field of clinical bone assessment for the diagnosis of osteoporosis.
Collapse
Affiliation(s)
- Kang Il Lee
- Acoustics Research Laboratory, BK21 Physics Research Division, Department of Physics, SungKyunKwan University, Suwon 440-746, Republic of Korea
| | | | | |
Collapse
|
23
|
Lee KI, Roh HS, Yoon SW. Correlations between acoustic properties and bone density in bovine cancellous bone from 0.5 to 2 MHz. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2003; 113:2933-2938. [PMID: 12765411 DOI: 10.1121/1.1567733] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Correlations between acoustic properties and bone density were investigated in the 12 defatted bovine cancellous bone specimens in vitro. Speed of sound (SOS) and broadband ultrasonic attenuation (BUA) were measured in three different frequency bandwidths from 0.5 to 2 MHz using three matched pairs of transducers with the center frequencies of 1, 2.25, and 3.5 MHz. The relative orientation between ultrasonic beam and bone specimen was the mediolateral (ML) direction of the bovine tibia. SOS shows significant linear positive correlation with apparent density for all three pairs of transducers. However, BUA shows relatively weak correlation with apparent density. SOS and BUA are only weakly correlated with each other. The linear combination of SOS and BUA in a multiple regression model leads to a significant improvement in predicting apparent density. The correlations among SOS, BUA, and bone density can be effectively and clearly represented in the three-dimensional space by the multiple regression model. These results suggest that the frequency range up to 1.5 MHz and the multiple regression model in the three-dimensional space can be useful in the osteoporosis diagnosis.
Collapse
Affiliation(s)
- Kang Il Lee
- Acoustics Research Laboratory, Department of Physics, SungKyunKwan University, Suwon 440-746, Republic of Korea
| | | | | |
Collapse
|
24
|
Hoffmeister BK, Auwarter JA, Rho JY. Effect of marrow on the high frequency ultrasonic properties of cancellous bone. Phys Med Biol 2002; 47:3419-27. [PMID: 12375829 DOI: 10.1088/0031-9155/47/18/310] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A number of investigators have performed in vitro measurements of cancellous bone to determine how various ultrasonic parameters depend on bone density and trabecular orientation. To facilitate handling and storage of bone specimens, the marrow is often removed prior to ultrasonic measurements. However, the assumption that marrow does not affect ultrasonic measurements at high frequencies (>1 MHz) has not been tested. The goal of this study is to determine the effect of marrow on the ultrasonic properties of bovine cancellous bone at frequencies greater than 1 MHz. Twelve specimens of cancellous bone were obtained from the proximal end of four bovine tibia. Ultrasonic measurements consisting of normalized broadband ultrasonic attenuation (nBUA), speed of sound (SOS) and apparent integrated backscatter (AIB) were measured in each specimen using 2.25 MHz (centre frequency) broadband ultrasonic pulses. These measurements were performed before and after marrow removal either along the superoinferior (SI) or mediolateral (ML) direction. SOS and nBUA showed no significant difference (p > 0.05) for either direction of propagation after marrow removal. AIB showed no significant difference in the SI direction. For the ML direction, a small but statistically significant difference (p = 0.044) was observed after marrow removal.
Collapse
|
25
|
Cheng S, Njeh CF, Fan B, Cheng X, Hans D, Wang L, Fuerst T, Genant HK. Influence of region of interest and bone size on calcaneal BMD: implications for the accuracy of quantitative ultrasound assessments at the calcaneus. Br J Radiol 2002; 75:59-68. [PMID: 11806960 DOI: 10.1259/bjr.75.889.750059] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
There is considerable technological diversity among quantitative ultrasound (QUS) devices used to assess osteoporosis. Because the distance between the transducer and the footplate remains constant, the location of the calcaneus measured will vary with foot size. This study was designed to quantify the variation in bone mineral density (BMD) between a manufacturer's region of interest (ROI_M), which is fixed relative to the footplate, and an anatomical region of interest (ROI_A), which is defined as 20% of calcaneal length. The effect of foot length and width on QUS variables measured using two Food and Drug Administration cleared QUS devices, the Sahara (Hologic) and the Achilles+ (Lunar) was assessed. 26 healthy subjects (12 male and 14 female), aged 22-54 years (35.6+/-10 years) and with foot lengths of 21.5 cm to 29.7 cm (25.1+/-2.3 cm) were recruited. QUS assessments were performed at the right calcaneus. In addition, a Hologic 4500 densitometer was used to measure the BMD of the calcaneus in the ROI_M and ROI_A. The sizes of the ROIs were approximated to the sizes of the transducers of the Sahara and Achilles+ devices. The results showed a significant difference in BMD between the two ROI locations for the Sahara device (BMD 0.642+/-0.135 g cm(-2) vs 0.616+/-0.114 g cm(-2), p=0.014), but no significant difference was found in BMD between the two locations for the Achilles device (BMD 0.661+/-0.120 g cm(-2) vs 0.662+/-0.123 g cm(-2), p=0.818). At the ROI_A, there was a significant difference in BMD between the two QUS devices (p<0.001). The correlation between QUS variables and BMD was slightly higher for the ROI_M (r=0.68-0.79, since this is site-matched) than the ROI_A (r=0.59-0.70) for the Achilles device, while for the Sahara device the correlations were r=0.35-0.40 and r=0.51-0.54, respectively. The smaller ROI of the Sahara device resulted in more than 50% of the subjects having BMD differences of greater than 5% between the ROI_A and the ROI_M, compared with only 20% of the subjects on the Achilles device. ROIs containing cortical bone edge and other soft tissues were found in 58% of cases for the Achilles device and 46% of cases for the Sahara device. The greatest differences occurred in very small and very large feet. Calcaneal length correlated significantly with Sahara speed of sound (SOS), and heel width correlated significantly with Achilles SOS. Heel width also correlated significantly with Sahara broadband ultrasound attenuation (BUA) but not Achilles+ BUA. These results suggest that variation in ROI and bone size might affect the accuracy of QUS measurements, since the calcaneus is heterogeneous both in terms of its external geometry and its internal structure and density.
Collapse
Affiliation(s)
- S Cheng
- Osteoporosis and Arthritis Research Group, Department of Radiology, University of California, San Francisco, 350 Parnassus Avenue, San Francisco, CA 94134-1349, USA
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Wear KA. A stratified model to predict dispersion in trabecular bone. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2001; 48:1079-83. [PMID: 11477766 PMCID: PMC9136584 DOI: 10.1109/58.935726] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Frequency-dependent phase velocity (dispersion) has previously been measured in trabecular bone by several groups. In contrast to most biologic tissues, phase velocity in trabecular bone tends to decrease with frequency. A stratified model, consisting of alternating layers of bone and marrow (in vivo) or water (in vitro), has been employed in an attempt to explain this phenomenon. Frequency-dependent phase velocity was measured from 300 to 700 kHz in 1) phantoms consisting of regularly spaced thin parallel layers of polystyrene sheets in water and 2) 30 calcaneus samples in vitro. For the polystyrene phantoms, the agreement between theory and experiment was good. For the calcaneus samples, the model has some limited usefulness (uncertainty of about 5%) in predicting average phase velocity. More importantly, the model seems to perform consistently well for predicting the frequency dependence of phase velocity in calcaneus.
Collapse
Affiliation(s)
- K A Wear
- U.S. Food and Drug Administration, Center for Devices and Radiological Health, HFZ-142, Rockville, MD 20852, USA.
| |
Collapse
|
27
|
Wear KA, Armstrong DW. Relationships among calcaneal backscatter, attenuation, sound speed, hip bone mineral density, and age in normal adult women. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2001; 110:573-8. [PMID: 11508981 PMCID: PMC8217742 DOI: 10.1121/1.1378343] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
The present study was undertaken in order to investigate the use of calcaneal ultrasonic backscatter for the application of diagnosis of osteoporosis. Broadband ultrasonic attenuation (BUA), speed of sound (SOS), the average backscatter coefficient (ABC), and the hip bone mineral density (BMD) were measured in calcanea in 47 women (average age: 58 years, standard deviation: 13 years). All three ultrasound variables had comparable correlations with hip BMD (around 0.5). As reported previously by others, BUA and SOS were rather highly correlated with each other. The logarithm of the ABC was only moderately correlated with the other two. The three ultrasound parameters exhibited similar moderate negative correlations with age. These results taken collectively suggest that the ABC may carry important diagnostic information independent of that contained in BUA and SOS and, therefore, may be useful as an adjunct measurement in the diagnosis of osteoporosis.
Collapse
Affiliation(s)
- K A Wear
- US Food and Drug Administration, Center for Devices and Radiological Health, Rockville, Maryland 20852, USA.
| | | |
Collapse
|
28
|
Wear KA. The effects of frequency-dependent attenuation and dispersion on sound speed measurements: applications in human trabecular bone. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2000; 47:265-73. [PMID: 18238539 PMCID: PMC9207814 DOI: 10.1109/58.818770] [Citation(s) in RCA: 75] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Sound speed may be measured by comparing the transit time of a broadband ultrasonic pulse transmitted through an object with that transmitted through a reference water path. If the speed of sound in water and the thickness of the sample are known, the speed of sound in the object may be computed. To measure the transit time differential, a marker such as a zero-crossing, may be used. A sound speed difference between the object and water shifts all markers backward or forward. Frequency-dependent attenuation and dispersion may alter the spectral characteristics of the waveform, thereby distorting the locations of markers and introducing variations in sound-speed estimates. Theory is derived to correct for this distortion for Gaussian pulses propagating through linearly attenuating, weakly dispersive media. The theory is validated using numerical analysis, measurements on a tissue mimicking phantom, and on 24 human calcaneus samples in vitro. Variations in soft tissue-like media are generally not exceptionally large for most applications but can be substantial, particularly for high bandwidth pulses propagating through media with high attenuation coefficients. At 500 kHz, variations in velocity estimates in bone can be very substantial, on the order of 40 to 50 m/s because of the high attenuation coefficient of bone. In trabecular bone, the effects of frequency-dependent attenuation are considerable, and the effects of dispersion are negligible.
Collapse
Affiliation(s)
- K A Wear
- U.S. Food and Drug Adm., Center for Devices and Radiol. Health, Rockville, MD, USA.
| |
Collapse
|
29
|
Abstract
Quantitative ultrasound (QUS) analysis of bone has been suggested to have a level of performance equal to dual-energy X-ray absorptiometry (DXA) for the assessment of fracture risk. In this study, QUS and DXA measurements were conducted on bovine trabecular bone in vitro using commercially available clinical instruments. The samples were then mechanically tested to obtain Young's modulus and ultimate strength. In addition, QUS and DXA parameters of the human calcaneus (n = 34) were measured in vivo. The measurements revealed a significant effect of bovine bone size on broadband ultrasound attenuation (BUA) and speed of sound (SOS) in vitro. By normalizing the DXA and QUS results with bone thickness we could systematically improve their ability to predict bone strength. However, in bovine trabecular bone, BUA showed no significant linear correlation with either bone mineral density (BMD), Young's modulus, or ultimate strength. This finding may be typical of only high-density and low-porosity bovine bone. We significantly improved prediction of ultimate strength by combining density and ultrasound velocity results as compared with assessments of volumetric BMDvol (p < 0.05) or SOS (p < 0.001) alone. However, the improvement was not significant if BMDvol, instead of wet density, was used. Altogether, 88% of the variation in the ultimate strength of bovine bone could be explained by combined density and ultrasound velocity. In vivo, SOS showed a weak negative correlation with heel width (r = -1.350). The in vivo measurements also showed a close correlation for BUA with BMD in the human calcaneus. This suggests that BUA is more suitable for quantitative analysis of low-density trabecular bone.
Collapse
Affiliation(s)
- J Töyräs
- Department of Clinical Physiology, Kuopio University Hospital, Finland
| | | | | |
Collapse
|
30
|
Njeh CF, Hans D, Wu C, Kantorovich E, Sister M, Fuerst T, Genant HK. An in vitro investigation of the dependence on sample thickness of the speed of sound along the specimen. Med Eng Phys 1999; 21:651-9. [PMID: 10699567 DOI: 10.1016/s1350-4533(99)00090-9] [Citation(s) in RCA: 94] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
To measure the speed of sound (SOS), most quantitative ultrasound (QUS) devices use the transmission mode, whereby two transducers are placed on opposite sides of the sample. This mode is limited to a few specific skeletal sites because of the varying configuration of bone geometry and varying amounts of overlying soft tissue at most other sites. The aim of this study was to address the dependence of SOS measured along the sample on the thickness and composition of the bone sample. Bovine samples from mid-femur and trochanter, and perspex phantoms were used. We prepared the perspex samples in the shapes of blocks and cylinders to investigate the effect of wall thickness on SOS. The thickness of the blocks was decreased in decrements of 1 mm; a 22 mm diameter hole was drilled through the cylindrical samples and the hole size was gradually increased. The second configuration was also used with the bovine samples. For each experimental set-up five SOS measurements were acquired, with the probe aligned along the sample and a mean value computed. All measurements were taken with castor oil as the coupling agent, and in the cylindrical cases, the oil was used to fill the tube. The measurement precision determined as the root mean square coefficient of variation (RMSCV) was determined to be 0.14% and 0.65% for perspex and bovine samples respectively. The measured SOS on the perspex phantom (2760+/-4 m/s) was within the published values for bulk velocity. It was observed that for both perspex and bovine samples the SOS was independent of sample wall thickness greater than the wavelength (2.2 mm, 2.7 mm and 3.5 mm for perspex, trochanter and mid-femur respectively). The SOS decreased with sample wall thickness smaller than the wavelength in concordance with theoretical predictions. The SOS values obtained for bovine samples reflected either totally cortical (mid-femur) or a composite of cortical and cancellous bone (trochanter).
Collapse
Affiliation(s)
- C F Njeh
- Osteoporosis and Arthritis Research Group, Department of Radiology, University of Califormia, 350 Parnassus Avenue, Suite 908, San Francisco, CA 94117-1349, USA.
| | | | | | | | | | | | | |
Collapse
|
31
|
Luo G, Kaufman JJ, Chiabrera A, Bianco B, Kinney JH, Haupt D, Ryaby JT, Siffert RS. Computational methods for ultrasonic bone assessment. ULTRASOUND IN MEDICINE & BIOLOGY 1999; 25:823-830. [PMID: 10414899 DOI: 10.1016/s0301-5629(99)00026-5] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Ultrasound has been proposed as a means to noninvasively assess bone and, particularly, bone strength and fracture risk. Although there has been some success in this application, there is still much that is unknown regarding the propagation of ultrasound through bone. Because strength and fracture risk are a function of both bone mineral density and architectural structure, this study was carried out to examine how architecture and density interact in ultrasound propagation. Due to the difficulties inherent in obtaining fresh bone specimens and associated architectural and density features, simulation methods were used to explore the interactions of ultrasound with bone. A sample of calcaneal trabecular bone was scanned with micro-CT and subjected to morphological image processing (erosions and dilations) operations to obtain a total of 15 three-dimensional (3-D) data sets. Fifteen two-dimensional (2-D) slices obtained from the 3-D data sets were then analyzed to evaluate their respective architectures and densities. The architecture was characterized through the fabric feature, and the density was represented in terms of the bone volume fraction. Computer simulations of ultrasonic propagation through each of the 15 2-D bone slices were carried out, and the ultrasonic velocity and mean frequency of the received waveforms were evaluated. Results demonstrate that ultrasound propagation is affected by both density and architecture, although there was not a simple linear correlation between the relative degree of structural anisotropy with the ultrasound measurements. This study elucidates further aspects of propagation of ultrasound through bone, and demonstrates as well as the power of computational methods for ultrasound research in general and tissue and bone characterization in particular.
Collapse
Affiliation(s)
- G Luo
- New York Department of Veterans Affairs Medical Center and Department of Rehabilitation Medicine, New York University Medical Center, NY, USA
| | | | | | | | | | | | | | | |
Collapse
|
32
|
Klötzsch C, Popescu O, Berlit P. A new 1-MHz probe for transcranial Doppler sonography in patients with inadequate temporal bone windows. ULTRASOUND IN MEDICINE & BIOLOGY 1998; 24:101-103. [PMID: 9483776 DOI: 10.1016/s0301-5629(97)00231-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Recent large-scale transcranial Doppler sonography (TCD) studies have revealed that, in 3%-5% of patients, the temporal bone window is insufficient for examination with 2-MHz probes. The diagnostic value of a new 1-MHz probe for TCD was compared with a standard 2-MHz probe in patients with an insufficient ultrasonic window. From a total population of 514 consecutive patients, the study involved only patients in whom a bad or absent temporal bone window was revealed during 2-MHz TCD examination. Fifty patients (39 women and 11 men) with a mean age of 71 +/- 9 y were investigated with a 2-MHz probe and subsequently with a 1-MHz probe. Using the 2-MHz probe, 18 patients (group I) lacked a temporal insonation window bilaterally, while 12 had an absent bone window unilaterally (group II). Twenty patients (group III) had bilateral bone windows, but with insufficient detection of the anterior and posterior cerebral arteries. In four of the 18 patients in group I (22%), the circle of Willis could be demonstrated with the 1-MHz probe. In 11 of the 12 patients in group II (92%), it was possible to demonstrate the contralateral vessels through the ipsilateral bone window with the 1-MHz probe, while this was only possible in 25% with the 2-MHz probe. All 20 patients of group III could be successfully examined with the 1-MHz probe. The 1-MHz probe provides an opportunity to perform TCD studies in older patients presenting with absent or insufficient temporal bone windows for examination with 2-MHz probes.
Collapse
Affiliation(s)
- C Klötzsch
- Department of Neurology, Rheinisch-Westfälische Technische Hochschule (RWTH) Aachen, Germany
| | | | | |
Collapse
|
33
|
Glüer CC. Quantitative ultrasound techniques for the assessment of osteoporosis: expert agreement on current status. The International Quantitative Ultrasound Consensus Group. J Bone Miner Res 1997; 12:1280-8. [PMID: 9258759 DOI: 10.1359/jbmr.1997.12.8.1280] [Citation(s) in RCA: 307] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Quantitative ultrasound (QUS) methods have been introduced in recent years for the assessment of skeletal status in osteoporosis. The performance of QUS techniques has been evaluated in a large number of studies. Reviewing existing knowledge, an international expert panel formulated the following consensus regarding the current status of this technology. To date, evidence supports the use of QUS techniques for the assessment of fracture risk in elderly women. This has been best established for water-based calcaneal QUS systems. Future studies should include the predictive validity of other QUS systems. Additional clinical applications of QUS, specifically the assessment of rates of change for monitoring disease progression or response to treatment, require further investigation. Its low cost and portability make QUS an attractive technology for assessing risk of fractures in larger populations than may be suitable or feasible for bone densitometry. Additional investigations that assess innovative QUS techniques in well defined research settings are important to determine and utilize the full potential of this technology for the benefit of early detection and monitoring of osteoporosis.
Collapse
|
34
|
Chen T, Tzeng JS, Lin CJ. A novel method to measure acoustic speed of bone tissue. ULTRASOUND IN MEDICINE & BIOLOGY 1997; 23:1337-1341. [PMID: 9428133 DOI: 10.1016/s0301-5629(97)00198-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Acoustic speed is an important parameter that can be used to characterize bone tissue for evaluation of osteoporosis. Traditional approaches for measuring acoustic speed require knowledge of either the specimen thickness, which is sometimes difficult to obtain from biological tissues, or the reference fluid velocity that, moreover, is an unknown parameter for internal tissue in in vivo measurement. In this paper, a new method is proposed to measure acoustic speed from dual reflected ultrasound signals. This technique utilizes two transducers placed on the same side of the test object; one for transmitter and receiver, and the other one for receiver only. The acoustic speed of the test object is based on the information of time-of-flight from the signals received by both transducers and the separation distance between the transducer pair. The technique developed here not only eliminates the requirement of knowledge of specimen thickness, but also shows a feasibility for clinical applications. The results of different porcine and bovine bone samples measured in vitro by this technique are in good agreement with those measured by other published methods. In vivo measurement results of 10 healthy young volunteers' tibias are also reported.
Collapse
Affiliation(s)
- T Chen
- Institute of Biomedical Engineering, National Cheng-Kung University, Tainan, Taiwan.
| | | | | |
Collapse
|
35
|
Alves JM, Ryaby JT, Kaufman JJ, Magee FP, Siffert RS. Influence of marrow on ultrasonic velocity and attenuation in bovine trabecular bone. Calcif Tissue Int 1996; 58:362-7. [PMID: 8661972 DOI: 10.1007/bf02509386] [Citation(s) in RCA: 45] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Measurements of ultrasonic velocity and specific differential attenuation (SDA) were obtained on 24 bovine trabecular bone specimens from the femoral condyles. The measurements were obtained using two pairs of ultrasonic transducers, one with a low nominal center frequency (500 kHz) and the other pair with a high nominal center frequency (1 MHz). The ultrasonic velocity and specific differential attenuation associated with the bone samples were determined both with and without marrow, i.e., replacing the marrow with water in the pores of the trabecular bone. Significant increases (2.1% and 2.9%) in the velocity of ultrasound were observed after removal of the marrow, for the low and high frequency transducer pairs, respectively. In contrast, significant decreases (-6.5% and -8.8%) in SDA were observed after removal of the marrow, for the low and high frequency transducer pairs, respectively. The bone densities (BD) of the samples were also determined using single photon absorptiometry (SPA). Correlations between ultrasonic parameters and bone densities for samples both with and without marrow were found to be similar. For example, for the 1 MHz transducer pair, the correlation between BD and velocity was r = 0. 86 with marrow, and r = 0.89 without marrow. This study also compared the results obtained using a contact (no water bath) technique and an insertion (with a water bath) technique of ultrasonic measurements. For the high frequency transducer pair, the correlation coefficients between the two methods were r = 0.99 and r = 0.93, for the velocity and specific differential attenuation, respectively. Similar results were found for the low frequency transducer pair as well. In addition, approximately equal correlations between BD and ultrasonic velocity and SDA were also found, indicating that contact and insertion measurements provide essentially equivalent information.
Collapse
Affiliation(s)
- J M Alves
- Department of Orthopaedics, MS 1188, The Mount Sinai School of Medicine, One Gustave L. Levy Place, New York, New York 10029, USA
| | | | | | | | | |
Collapse
|