1
|
Fallahzadeh Abarghuei A, Karimi MT. The Effects of Lower Limb Orthoses on Health Aspects of the Spinal Cord Injury Patients: A Systematic Review Using International Classification of Functioning, Disability, and Health (ICF) as a Reference Framework. Med J Islam Repub Iran 2022; 36:153. [PMID: 36654846 PMCID: PMC9832937 DOI: 10.47176/mjiri.36.153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Indexed: 12/24/2022] Open
Abstract
Background: One of the most important approaches in the rehabilitation of spinal cord injury (SCI) patients is the use of different orthoses. To date, no review has been published that analyzed the effects of orthoses on health aspects of spinal cord injury clients using the International Classification of Functioning, Disability and Health (ICF). Methods: A systematic literature search was done in some databases, including Medline, PubMed, Cochrane centered register of the controlled trial (CCTR), Cochrane database of systematic reviews (CDSR), a database of abstracts of reviews of effects (DARE), Embase, Google Scholar, and ISI Web of Knowledge. SCI was used in conjunction with terms like orthotic device, mechanical orthoses, external power orthoses, assistive devices, and functional electrical. The time frame for this search was from 1970 to 2022. Results: A total of 200 papers were found. Based on the titles and abstracts, 100 related papers were detected. After careful evaluation of the papers, 47 studies were selected for final analysis-53 papers were excluded due to duplication, non-English language, and lack of full-text. Conclusion: The results of 32 studies (70% of studies) support the efficiency of orthoses in walking and standing of SCI patients. In most of the included studies, the efficiency of orthoses was evaluated mostly based on body functions and structures, and their impact on other outcomes such as participation and quality of life (QoL) of SCI patients was unclear.
Collapse
Affiliation(s)
- Abolghasem Fallahzadeh Abarghuei
- Department of Occupational Therapy, School of Rehabilitation Sciences, Shiraz
University of Medical Sciences, Shiraz, Iran
- Rehabilitation Sciences Research Center, Shiraz University of Medical Sciences,
Shiraz, Iran
| | - Mohammad Taghi Karimi
- Rehabilitation Sciences Research Center, Shiraz University of Medical Sciences,
Shiraz, Iran
| |
Collapse
|
2
|
Neťuková S, Bejtic M, Malá C, Horáková L, Kutílek P, Kauler J, Krupička R. Lower Limb Exoskeleton Sensors: State-of-the-Art. SENSORS (BASEL, SWITZERLAND) 2022; 22:9091. [PMID: 36501804 PMCID: PMC9738474 DOI: 10.3390/s22239091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Revised: 11/08/2022] [Accepted: 11/17/2022] [Indexed: 06/17/2023]
Abstract
Due to the ever-increasing proportion of older people in the total population and the growing awareness of the importance of protecting workers against physical overload during long-time hard work, the idea of supporting exoskeletons progressed from high-tech fiction to almost commercialized products within the last six decades. Sensors, as part of the perception layer, play a crucial role in enhancing the functionality of exoskeletons by providing as accurate real-time data as possible to generate reliable input data for the control layer. The result of the processed sensor data is the information about current limb position, movement intension, and needed support. With the help of this review article, we want to clarify which criteria for sensors used in exoskeletons are important and how standard sensor types, such as kinematic and kinetic sensors, are used in lower limb exoskeletons. We also want to outline the possibilities and limitations of special medical signal sensors detecting, e.g., brain or muscle signals to improve data perception at the human-machine interface. A topic-based literature and product research was done to gain the best possible overview of the newest developments, research results, and products in the field. The paper provides an extensive overview of sensor criteria that need to be considered for the use of sensors in exoskeletons, as well as a collection of sensors and their placement used in current exoskeleton products. Additionally, the article points out several types of sensors detecting physiological or environmental signals that might be beneficial for future exoskeleton developments.
Collapse
|
3
|
Converging Robotic Technologies in Targeted Neural Rehabilitation: A Review of Emerging Solutions and Challenges. SENSORS 2021; 21:s21062084. [PMID: 33809721 PMCID: PMC8002299 DOI: 10.3390/s21062084] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 03/05/2021] [Accepted: 03/11/2021] [Indexed: 11/17/2022]
Abstract
Recent advances in the field of neural rehabilitation, facilitated through technological innovation and improved neurophysiological knowledge of impaired motor control, have opened up new research directions. Such advances increase the relevance of existing interventions, as well as allow novel methodologies and technological synergies. New approaches attempt to partially overcome long-term disability caused by spinal cord injury, using either invasive bridging technologies or noninvasive human-machine interfaces. Muscular dystrophies benefit from electromyography and novel sensors that shed light on underlying neuromotor mechanisms in people with Duchenne. Novel wearable robotics devices are being tailored to specific patient populations, such as traumatic brain injury, stroke, and amputated individuals. In addition, developments in robot-assisted rehabilitation may enhance motor learning and generate movement repetitions by decoding the brain activity of patients during therapy. This is further facilitated by artificial intelligence algorithms coupled with faster electronics. The practical impact of integrating such technologies with neural rehabilitation treatment can be substantial. They can potentially empower nontechnically trained individuals-namely, family members and professional carers-to alter the programming of neural rehabilitation robotic setups, to actively get involved and intervene promptly at the point of care. This narrative review considers existing and emerging neural rehabilitation technologies through the perspective of replacing or restoring functions, enhancing, or improving natural neural output, as well as promoting or recruiting dormant neuroplasticity. Upon conclusion, we discuss the future directions for neural rehabilitation research, diagnosis, and treatment based on the discussed technologies and their major roadblocks. This future may eventually become possible through technological evolution and convergence of mutually beneficial technologies to create hybrid solutions.
Collapse
|
4
|
Grimmer M, Zeiss J, Weigand F, Zhao G, Lamm S, Steil M, Heller A. Lower limb joint biomechanics-based identification of gait transitions in between level walking and stair ambulation. PLoS One 2020; 15:e0239148. [PMID: 32936793 PMCID: PMC7494088 DOI: 10.1371/journal.pone.0239148] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Accepted: 08/31/2020] [Indexed: 11/19/2022] Open
Abstract
Lower limb exoskeletons and lower limb prostheses have the potential to reduce gait limitations during stair ambulation. To develop robotic assistance devices, the biomechanics of stair ambulation and the required transitions to level walking have to be understood. This study aimed to identify the timing of these transitions, to determine if transition phases exist and how long they last, and to investigate if there exists a joint-related order and timing for the start and end of the transitions. Therefore, this study analyzed the kinematics and kinetics of both transitions between level walking and stair ascent, and between level walking and stair descent (12 subjects, 25.4 yrs, 74.6 kg). We found that transitions primarily start within the stance phase and end within the swing phase. Transition phases exist for each limb, all joints (hip, knee, ankle), and types of transitions. They have a mean duration of half of one stride and they do not last longer than one stride. The duration of the transition phase for all joints of a single limb in aggregate is less than 35% of one stride in all but one case. The distal joints initialize stair ascent, while the proximal joints primarily initialize the stair descent transitions. In general, the distal joints complete the transitions first. We believe that energy- and balance-related processes are responsible for the joint-specific transition timing. Regarding the existence of a transition phase for all joints and transitions, we believe that lower limb exoskeleton or prosthetic control concepts should account for these transitions in order to improve the smoothness of the transition and to thus increase the user comfort, safety, and user experience. Our gait data and the identified transition timings can provide a reference for the design and the performance of stair ambulation- related control concepts.
Collapse
Affiliation(s)
- Martin Grimmer
- Institute for Sports Science, Technical University of Darmstadt, Darmstadt, Hesse, Germany
| | - Julian Zeiss
- Institute of Automatic Control and Mechatronics, Technical University of Darmstadt, Darmstadt, Hesse, Germany
| | - Florian Weigand
- Institute of Automatic Control and Mechatronics, Technical University of Darmstadt, Darmstadt, Hesse, Germany
| | - Guoping Zhao
- Institute for Sports Science, Technical University of Darmstadt, Darmstadt, Hesse, Germany
| | - Sascha Lamm
- Technical University of Darmstadt, Darmstadt, Hesse, Germany
| | - Martin Steil
- Technical University of Darmstadt, Darmstadt, Hesse, Germany
| | - Adrian Heller
- Technical University of Darmstadt, Darmstadt, Hesse, Germany
| |
Collapse
|
5
|
Karunakaran KK, Abbruzzese K, Androwis G, Foulds RA. A Novel User Control for Lower Extremity Rehabilitation Exoskeletons. Front Robot AI 2020; 7:108. [PMID: 33501275 PMCID: PMC7805763 DOI: 10.3389/frobt.2020.00108] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Accepted: 07/13/2020] [Indexed: 01/28/2023] Open
Abstract
Lower extremity exoskeletons offer the potential to restore ambulation to individuals with paraplegia due to spinal cord injury. However, they often rely on preprogrammed gait, initiated by switches, sensors, and/or EEG triggers. Users can exercise only limited independent control over the trajectory of the feet, the speed of walking, and the placement of feet to avoid obstacles. In this paper, we introduce and evaluate a novel approach that naturally decodes a neuromuscular surrogate for a user's neutrally planned foot control, uses the exoskeleton's motors to move the user's legs in real-time, and provides sensory feedback to the user allowing real-time sensation and path correction resulting in gait similar to biological ambulation. Users express their desired gait by applying Cartesian forces via their hands to rigid trekking poles that are connected to the exoskeleton feet through multi-axis force sensors. Using admittance control, the forces applied by the hands are converted into desired foot positions, every 10 milliseconds (ms), to which the exoskeleton is moved by its motors. As the trekking poles reflect the resulting foot movement, users receive sensory feedback of foot kinematics and ground contact that allows on-the-fly force corrections to maintain the desired foot behavior. We present preliminary results showing that our novel control can allow users to produce biologically similar exoskeleton gait.
Collapse
Affiliation(s)
- Kiran K Karunakaran
- Kessler Foundation, West Orange, NJ, United States.,Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, United States
| | - Kevin Abbruzzese
- Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, United States.,Stryker Corporation, Mahwah, NJ, United States
| | - Ghaith Androwis
- Kessler Foundation, West Orange, NJ, United States.,Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, United States
| | - Richard A Foulds
- Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, United States.,Really Useful Robots, LLC, Langhorne, PA, United States
| |
Collapse
|
6
|
Hobbs B, Artemiadis P. A Review of Robot-Assisted Lower-Limb Stroke Therapy: Unexplored Paths and Future Directions in Gait Rehabilitation. Front Neurorobot 2020; 14:19. [PMID: 32351377 PMCID: PMC7174593 DOI: 10.3389/fnbot.2020.00019] [Citation(s) in RCA: 60] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2020] [Accepted: 03/16/2020] [Indexed: 01/28/2023] Open
Abstract
Stroke affects one out of every six people on Earth. Approximately 90% of stroke survivors have some functional disability with mobility being a major impairment, which not only affects important daily activities but also increases the likelihood of falling. Originally intended to supplement traditional post-stroke gait rehabilitation, robotic systems have gained remarkable attention in recent years as a tool to decrease the strain on physical therapists while increasing the precision and repeatability of the therapy. While some of the current methods for robot-assisted rehabilitation have had many positive and promising outcomes, there is moderate evidence of improvement in walking and motor recovery using robotic devices compared to traditional practice. In order to better understand how and where robot-assisted rehabilitation has been effective, it is imperative to identify the main schools of thought that have prevailed. This review intends to observe those perspectives through three different lenses: the goal and type of interaction, the physical implementation, and the sensorimotor pathways targeted by robotic devices. The ways that researchers approach the problem of restoring gait function are grouped together in an intuitive way. Seeing robot-assisted rehabilitation in this unique light can naturally provoke the development of new directions to potentially fill the current research gaps and eventually discover more effective ways to provide therapy. In particular, the idea of utilizing the human inter-limb coordination mechanisms is brought up as an especially promising area for rehabilitation and is extensively discussed.
Collapse
Affiliation(s)
| | - Panagiotis Artemiadis
- Human-Oriented Robotics and Control Laboratory, Department of Mechanical Engineering, University of Delaware, Newark, DE, United States
| |
Collapse
|
7
|
Stair-ascent strategies and performance evaluation for a lower limb exoskeleton. INTERNATIONAL JOURNAL OF INTELLIGENT ROBOTICS AND APPLICATIONS 2020. [DOI: 10.1007/s41315-020-00123-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
8
|
Gasparri GM, Luque J, Lerner ZF. Proportional Joint-Moment Control for Instantaneously Adaptive Ankle Exoskeleton Assistance. IEEE Trans Neural Syst Rehabil Eng 2019; 27:751-759. [PMID: 30908231 DOI: 10.1109/tnsre.2019.2905979] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Lower-limb exoskeletons used to improve free-living mobility for individuals with neuromuscular impairment must be controlled to prescribe assistance that adapts to the diverse locomotor conditions encountered during daily life, including walking at different speeds and across varied terrain. The goal of this paper is to design and establish clinical feasibility of an ankle exoskeleton control strategy that instantly and appropriately adjusts assistance to the changing biomechanical demand during variable walking. To accomplish this goal, we developed a proportional joint-moment control strategy that prescribes assistance as a function of the instantaneous estimate of the ankle joint moment and conducted a laboratory-based feasibility study. Four individuals with neuromotor impairment and one unimpaired individual completed exoskeleton-assisted slow and fast gait transition tasks that involved gait initiation and changing walking speed. We found that the controller was effective in instantaneously prescribing exoskeleton assistance that was proportional to the ankle moment with less than 14% root-mean-square error, on average. We also performed a three-subject pilot investigation to determine the ability of the proportional joint-moment controller to improve walking economy. Evaluated in two individuals with cerebral palsy and one unimpaired individual, metabolic cost of transport improved 17-27% during treadmill and over-ground walking with proportional control compared with wearing the exoskeleton unassisted. These preliminary findings support the continued investigation of proportional joint-moment control for assisting individuals with neuromuscular disabilities during walking in real-world settings.
Collapse
|
9
|
Nataraj R, van den Bogert AJ. Simulation Analysis of Linear Quadratic Regulator Control of Sagittal-Plane Human Walking-Implications for Exoskeletons. J Biomech Eng 2019; 139:2648716. [PMID: 28787476 DOI: 10.1115/1.4037560] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The linear quadratic regulator (LQR) is a classical optimal control approach that can regulate gait dynamics about target kinematic trajectories. Exoskeletons to restore gait function have conventionally utilized time-varying proportional-derivative (PD) control of leg joints. But, these PD parameters are not uniquely optimized for whole-body (full-state) performance. The objective of this study was to investigate the effectiveness of LQR full-state feedback compared to PD control to maintain bipedal walking of a sagittal-plane computational model against force disturbances. Several LQR controllers were uniquely solved with feedback gains optimized for different levels of tracking capability versus control effort. The main implications to future exoskeleton control systems include (1) which LQR controllers out-perform PD controllers in walking maintenance and effort, (2) verifying that LQR desirably produces joint torques that oppose rapidly growing joint state errors, and (3) potentially equipping accurate sensing systems for nonjoint states such as hip-position and torso orientation. The LQR controllers capable of longer walk times than respective PD controllers also required less control effort. During sudden leg collapse, LQR desirably behaved like PD by generating feedback torques that opposed the direction of leg-joint errors. Feedback from nonjoint states contributed to over 50% of the LQR joint torques and appear critical for whole-body LQR control. While LQR control poses implementation challenges, such as more sensors for full-state feedback and operation near the desired trajectories, it offers significant performance advantages over PD control.
Collapse
|
10
|
Kim DS, Lee HJ, Lee SH, Chang WH, Jang J, Choi BO, Ryu GH, Kim YH. A wearable hip-assist robot reduces the cardiopulmonary metabolic energy expenditure during stair ascent in elderly adults: a pilot cross-sectional study. BMC Geriatr 2018; 18:230. [PMID: 30268096 PMCID: PMC6162880 DOI: 10.1186/s12877-018-0921-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2018] [Accepted: 09/16/2018] [Indexed: 12/02/2022] Open
Abstract
Background Stair ascent is one of the most important and challenging activities of daily living to maintain mobility and independence in elderly adults. Recently, various types of wearable walking assist robots have been developed to improve gait function and metabolic efficiency for elderly adults. Several studies have shown that walking assist robots can improve cardiopulmonary metabolic efficiency during level walking in elderly. However, there is limited evidence demonstrating the effect of walking assist robots on cardiopulmonary metabolic efficiency during stair walking in elderly adults. Therefore, the aim of this study was to investigate the assistance effect of a newly developed wearable hip assist robot on cardiopulmonary metabolic efficiency during stair ascent in elderly adults. Methods Fifteen healthy elderly adults participated. The Gait Enhancing Mechatronic System (GEMS), developed by Samsung Electronics Co., Ltd., Korea, was used in the present study. The metabolic energy expenditure was measured using a K4b2 while participants performed randomly assigned two conditions consecutively: free ascending stairs without the GEMS or robot-assisted ascending stair with the GEMS. Results There were significant differences in the oxygen consumption per unit mass (ml/min/kg), metabolic power per unit mass (W/kg) and metabolic equivalents (METs) values between the GEMS and NoGEMS conditions. A statistically significant difference was found between the two conditions in net oxygen consumption and net metabolic power, with a reduction of 8.59% and 10.16% respectively in GEMS condition (p < 0.05). The gross oxygen consumption while climbing stairs under the GEMS and NoGEMS conditions was equivalent to 6.38 METs and 6.85 METs, respectively. Conclusion This study demonstrated that the GEMS was helpful for reducing cardiopulmonary metabolic energy expenditure during stair climbing in elderly adults. The use of the GEMS allows elderly adults to climb stairs with less metabolic energy, therefore, they may experience more endurance in stair climbing while using the GEMS. Trial registration NCT03389165, Registered 26 December 2017 - retrospectively registered
Collapse
Affiliation(s)
- Dong-Seok Kim
- Department of Physical and Rehabilitation Medicine, Center for Prevention & Rehabilitation, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Irwon-ro 81, Gangnam-gu, Seoul, 06351, Republic of Korea.,Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Irwon-ro 81, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Hwang-Jae Lee
- Department of Physical and Rehabilitation Medicine, Center for Prevention & Rehabilitation, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Irwon-ro 81, Gangnam-gu, Seoul, 06351, Republic of Korea.,Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Irwon-ro 81, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Su-Hyun Lee
- Department of Physical and Rehabilitation Medicine, Center for Prevention & Rehabilitation, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Irwon-ro 81, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Won Hyuk Chang
- Department of Physical and Rehabilitation Medicine, Center for Prevention & Rehabilitation, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Irwon-ro 81, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Junwon Jang
- Samsung Advanced Institute of Technology, Samsung Electronics, 130 Samsung-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16678, Republic of Korea
| | - Byung-Ok Choi
- Department of Neurology, Neuroscience Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Irwon-ro 81, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Gyu-Ha Ryu
- Office of Biomechanical science, Research Center for Future Medicine, Samsung Medical Center, Sungkyunkwan University, Irwon-ro 81, Gangnam-gu, Seoul, 06351, Republic of Korea.
| | - Yun-Hee Kim
- Department of Physical and Rehabilitation Medicine, Center for Prevention & Rehabilitation, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Irwon-ro 81, Gangnam-gu, Seoul, 06351, Republic of Korea. .,Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Irwon-ro 81, Gangnam-gu, Seoul, 06351, Republic of Korea.
| |
Collapse
|
11
|
Ekelem A, Bastas G, Durrough CM, Goldfarb M. Variable Geometry Stair Ascent and Descent Controller for a Powered Lower Limb Exoskeleton. J Med Device 2018. [DOI: 10.1115/1.4040699] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
This paper describes a control approach for a lower limb exoskeleton intended to enable stair ascent and descent of variable geometry staircases for individuals with paraplegia resulting from spinal cord injury (SCI). To assess the efficacy of ascent and descent functionality provided by the control approach, the controller was implemented in a lower limb exoskeleton and tested in experimental trials on three subjects with motor-complete SCI on three staircases of varying geometry. Results from the assessments indicate that subjects were able to capably ascend and descend step heights varying from 7.6 to 16.5 cm without changing control settings; the controller provided for step time consistency highly representative of healthy subjects (9.2% variation in exoskeleton step time, relative to 7.7% variation in healthy subjects); and the exoskeleton provided peak joint torques on average 110% and 74% of the healthy-subject peak joint torques during stair ascent and descent, respectively. Subject perceived exertion during the stair ascent and descent activities was rated between “light” and “very light.”
Collapse
Affiliation(s)
- Andrew Ekelem
- Department of Mechanical Engineering, Vanderbilt University, 2400 Highland Avenue Olin Hall Room 101, Nashville, TN 37212 e-mail:
| | - Gerasimos Bastas
- Department of Physical Medicine and Rehabilitation, Vanderbilt University, Nashville, TN 37212 e-mail:
| | - Christina M. Durrough
- Pi Beta Phi Rehabilitation Institute, Vanderbilt Bill Wilkerson Center, 1215 21st Avenue South, Suite 9211, Nashville, TN 37232 e-mail:
| | - Michael Goldfarb
- Mem. ASME Department of Mechanical Engineering, Vanderbilt University, 2400 Highland Avenue Olin Hall Room 101, Nashville, TN 37212 e-mail:
| |
Collapse
|
12
|
Huo W, Mohammed S, Amirat Y, Kong K. Fast Gait Mode Detection and Assistive Torque Control of an Exoskeletal Robotic Orthosis for Walking Assistance. IEEE T ROBOT 2018. [DOI: 10.1109/tro.2018.2830367] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
13
|
Karunakaran KK, Abbruzzese KM, Xu H, Foulds RA. The Importance of Haptics in Generating Exoskeleton Gait Trajectory Using Alternate Motor Inputs. IEEE Trans Neural Syst Rehabil Eng 2017; 25:2328-2335. [PMID: 28715331 DOI: 10.1109/tnsre.2017.2726538] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Human gait requires both haptic and visual feedback to generate and control rhythmic movements, and navigate environmental obstacles. Current lower extremity wearable exoskeletons that restore gait to individuals with paraplegia due to spinal cord injury rely completely on visual feedback to generate limited pre-programmed gait variations, and generally provide little control by the user over the gait cycle. As an alternative to this limitation, we propose user control of gait in real time using healthy upper extremities. This paper evaluates the feedback conditions required for the hands to generate complex rhythmic trajectories that resemble gait trajectories. This paper involved 18 subjects who performed a virtual locomotor task, where contralateral hand movements were mapped to control virtual feet in three feedback conditions: haptic only, visual only, and haptic and visual. The results indicate that haptic feedback in addition to visual feedback is required to produce rhythmic hand trajectories similar to gait trajectories.
Collapse
|
14
|
He Y, Eguren D, Luu TP, Contreras-Vidal JL. Risk management and regulations for lower limb medical exoskeletons: a review. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2017; 10:89-107. [PMID: 28533700 PMCID: PMC5431736 DOI: 10.2147/mder.s107134] [Citation(s) in RCA: 56] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
Gait disability is a major health care problem worldwide. Powered exoskeletons have recently emerged as devices that can enable users with gait disabilities to ambulate in an upright posture, and potentially bring other clinical benefits. In 2014, the US Food and Drug Administration approved marketing of the ReWalk™ Personal Exoskeleton as a class II medical device with special controls. Since then, Indego™ and Ekso™ have also received regulatory approval. With similar trends worldwide, this industry is likely to grow rapidly. On the other hand, the regulatory science of powered exoskeletons is still developing. The type and extent of probable risks of these devices are yet to be understood, and industry standards are yet to be developed. To address this gap, Manufacturer and User Facility Device Experience, Clinicaltrials.gov, and PubMed databases were searched for reports of adverse events and inclusion and exclusion criteria involving the use of lower limb powered exoskeletons. Current inclusion and exclusion criteria, which can determine probable risks, were found to be diverse. Reported adverse events and identified risks of current devices are also wide-ranging. In light of these findings, current regulations, standards, and regulatory procedures for medical device applications in the USA, Europe, and Japan were also compared. There is a need to raise awareness of probable risks associated with the use of powered exoskeletons and to develop adequate countermeasures, standards, and regulations for these human-machine systems. With appropriate risk mitigation strategies, adequate standards, comprehensive reporting of adverse events, and regulatory oversight, powered exoskeletons may one day allow individuals with gait disabilities to safely and independently ambulate.
Collapse
Affiliation(s)
- Yongtian He
- Laboratory for Noninvasive, Brain-Machine Interface Systems, Department of Electrical and Computer Engineering, University of Houston, Houston, TX, USA
| | - David Eguren
- Laboratory for Noninvasive, Brain-Machine Interface Systems, Department of Electrical and Computer Engineering, University of Houston, Houston, TX, USA
| | - Trieu Phat Luu
- Laboratory for Noninvasive, Brain-Machine Interface Systems, Department of Electrical and Computer Engineering, University of Houston, Houston, TX, USA
| | - Jose L Contreras-Vidal
- Laboratory for Noninvasive, Brain-Machine Interface Systems, Department of Electrical and Computer Engineering, University of Houston, Houston, TX, USA
| |
Collapse
|
15
|
Ekelem A, Murray S, Goldfarb M. Preliminary assessment of variable geometry stair ascent and descent with a powered lower limb orthosis for individuals with paraplegia. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:4671-4. [PMID: 26737336 DOI: 10.1109/embc.2015.7319436] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
This paper describes a controller for a lower-limb exoskeleton that enables variable-geometry stair ascent and descent for persons with lower limb paralysis. The controller was evaluated on a subject with T10 complete spinal cord injury (SCI) on two staircases, one with a riser height and tread depth of 18.4 × 27.9 cm (7.25 × 11 in) and the other 17.8 × 29.8 cm (7 × 11.75 in). The controller enabled ascent and descent of both staircases without explicit tuning for each, and with an average step rate of 12.9 step/min during ascent and 14.6 step/min during descent.
Collapse
|
16
|
Federici S, Meloni F, Bracalenti M, De Filippis ML. The effectiveness of powered, active lower limb exoskeletons in neurorehabilitation: A systematic review. NeuroRehabilitation 2016; 37:321-40. [PMID: 26529583 DOI: 10.3233/nre-151265] [Citation(s) in RCA: 70] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
OBJECTIVE This review examines the utility of current active, powered, wearable lower limb exoskeletons as aids to rehabilitation in paraplegic patients with gait disorders resulting from central nervous system lesions. METHODS The PRISMA guidelines were used to review literature on the use of powered and active lower limb exoskeletons for neurorehabilitative training in paraplegic subjects retrieved in a search of the electronic databases PubMed, EBSCO, Web of Science, Scopus, ProQuest, and Google Scholar. RESULTS We reviewed 27 studies published between 2001 and 2014, involving a total of 144 participants from the USA, Japan, Germany, Sweden, Israel, Italy, and Spain. Seventy percent of the studies were experimental tests of safety or efficacy and 29% evaluated rehabilitative effectiveness through uncontrolled (22%) or controlled (7%) clinical trials. CONCLUSIONS Exoskeletons provide a safe and practical method of neurorehabilitation which is not physically exhausting and makes minimal demands on working memory. It is easy to learn to use an exoskeleton and they increase mobility, improve functioning and reduce the risk of secondary injury by reinstating a more normal gait pattern. A limitation of the field is the lack of experimental methods for demonstrating the relative effectiveness of the exoskeleton in comparison with other rehabilitative techniques and technologies.
Collapse
Affiliation(s)
- Stefano Federici
- Department of Philosophy, Social & Human Sciences and Education, University of Perugia, Italy
| | - Fabio Meloni
- Department of Philosophy, Social & Human Sciences and Education, University of Perugia, Italy
| | - Marco Bracalenti
- Department of Philosophy, Social & Human Sciences and Education, University of Perugia, Italy
| | - Maria Laura De Filippis
- NIHR MindTech Healthcare Technology Co-operative, Institute of Mental Health, Jubilee Campus, Nottingham, UK
| |
Collapse
|
17
|
Asselin PK, Avedissian M, Knezevic S, Kornfeld S, Spungen AM. Training Persons with Spinal Cord Injury to Ambulate Using a Powered Exoskeleton. J Vis Exp 2016:54071. [PMID: 27340808 PMCID: PMC4927801 DOI: 10.3791/54071] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023] Open
Abstract
Powered exoskeletons have become available for overground ambulation in persons with paralyses due to spinal cord injury (SCI) who have intact upper extremity function and are able to maintain upright balance using forearm crutches. To ambulate in an exoskeleton, the user must acquire the ability to maintain balance while standing, sitting and appropriate weight shifting with each step. This can be a challenging task for those with deficits in sensation and proprioception in their lower extremities. This manuscript describes screening criteria and a training program developed at the James J. Peters VA Medical Center, Bronx, NY to teach users the skills needed to utilize these devices in institutional, home or community environments. Before training can begin, potential users are screened for appropriate range of motion of the hip, knee and ankle joints. Persons with SCI are at an increased risk of sustaining lower extremity fractures, even with minimal strain or trauma, therefore a bone mineral density assessment is performed to reduce the risk of fracture. Also, as part of screening, a physical examination is performed in order to identify additional health-related contraindications. Once the person has successfully passed all screening requirements, they are cleared to begin the training program. The device is properly adjusted to fit the user. A series of static and dynamic balance tasks are taught and performed by the user before learning to walk. The person is taught to ambulate in various environments ranging from indoor level surfaces to outdoors over uneven or changing surfaces. Once skilled enough to be a candidate for home use with the exoskeleton, the user is then required to designate a companion-walker who will train alongside them. Together, the pair must demonstrate the ability to perform various advanced tasks in order to be permitted to use the exoskeleton in their home/community environment.
Collapse
Affiliation(s)
- Pierre K Asselin
- Department of Veterans Affairs (VA) Rehabilitation Research and Development National Center of Excellence for the Medical Consequences of Spinal Cord Injury, James J. Peters VA Medical Center
| | - Manuel Avedissian
- Department of Veterans Affairs (VA) Rehabilitation Research and Development National Center of Excellence for the Medical Consequences of Spinal Cord Injury, James J. Peters VA Medical Center
| | - Steven Knezevic
- Department of Veterans Affairs (VA) Rehabilitation Research and Development National Center of Excellence for the Medical Consequences of Spinal Cord Injury, James J. Peters VA Medical Center
| | - Stephen Kornfeld
- Department of Veterans Affairs (VA) Spinal Cord Injury Service, James J. Peters VA Medical Center
| | - Ann M Spungen
- Department of Veterans Affairs (VA) Rehabilitation Research and Development National Center of Excellence for the Medical Consequences of Spinal Cord Injury, James J. Peters VA Medical Center;
| |
Collapse
|
18
|
Asselin P, Knezevic S, Kornfeld S, Cirnigliaro C, Agranova-Breyter I, Bauman WA, Spungen AM. Heart rate and oxygen demand of powered exoskeleton-assisted walking in persons with paraplegia. ACTA ACUST UNITED AC 2016; 52:147-58. [PMID: 26230182 DOI: 10.1682/jrrd.2014.02.0060] [Citation(s) in RCA: 98] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2014] [Revised: 12/22/2014] [Indexed: 12/14/2022]
Abstract
UNLABELLED Historically, persons with paralysis have limited options for overground ambulation. Recently, powered exoskeletons have become available, which are systems that translate the user's body movements to activate motors to move the lower limbs through a predetermined gait pattern. As part of an ongoing clinical study (NCT01454570), eight nonambulatory persons with paraplegia were trained to ambulate with a powered exoskeleton. Measurements of oxygen uptake (VO2) and heart rate (HR) were recorded for 6 min each during each maneuver while sitting, standing, and walking. The average value of VO2 during walking (11.2 +/- 1.7 mL/kg/min) was significantly higher than those for sitting and standing (3.5 +/- 0.4 and 4.3 +/- 0.9 mL/kg/min, respectively; p < 0.001). The HR response during walking was significantly greater than that of either sitting or standing (118 +/- 21vs 70 +/- 10 and 81 +/- 12 beats per minute, respectively: p < 0.001). Persons with paraplegia were able to ambulate efficiently using the powered exoskeleton for overground ambulation, providing potential for functional gain and improved fitness. CLINICAL TRIAL REGISTRATION ClinicalTrials.gov; NCT01454570; "The ReWalk Exoskeletal Walking System for Persons with Paraplegia (VA_ReWalk)"; https://clinicaltrials.gov/ct2/show/NCT01454570.
Collapse
Affiliation(s)
- Pierre Asselin
- Department of Veterans Affairs (VA) Rehabilitation Research and Development National Center of Excellence for the Medical Consequences of Spinal Cord Injury
| | | | | | | | | | | | | |
Collapse
|
19
|
Tucker MR, Olivier J, Pagel A, Bleuler H, Bouri M, Lambercy O, Millán JDR, Riener R, Vallery H, Gassert R. Control strategies for active lower extremity prosthetics and orthotics: a review. J Neuroeng Rehabil 2015; 12:1. [PMID: 25557982 PMCID: PMC4326520 DOI: 10.1186/1743-0003-12-1] [Citation(s) in RCA: 353] [Impact Index Per Article: 39.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2014] [Accepted: 12/05/2014] [Indexed: 12/11/2022] Open
Abstract
: Technological advancements have led to the development of numerous wearable robotic devices for the physical assistance and restoration of human locomotion. While many challenges remain with respect to the mechanical design of such devices, it is at least equally challenging and important to develop strategies to control them in concert with the intentions of the user.This work reviews the state-of-the-art techniques for controlling portable active lower limb prosthetic and orthotic (P/O) devices in the context of locomotive activities of daily living (ADL), and considers how these can be interfaced with the user's sensory-motor control system. This review underscores the practical challenges and opportunities associated with P/O control, which can be used to accelerate future developments in this field. Furthermore, this work provides a classification scheme for the comparison of the various control strategies.As a novel contribution, a general framework for the control of portable gait-assistance devices is proposed. This framework accounts for the physical and informatic interactions between the controller, the user, the environment, and the mechanical device itself. Such a treatment of P/Os--not as independent devices, but as actors within an ecosystem--is suggested to be necessary to structure the next generation of intelligent and multifunctional controllers.Each element of the proposed framework is discussed with respect to the role that it plays in the assistance of locomotion, along with how its states can be sensed as inputs to the controller. The reviewed controllers are shown to fit within different levels of a hierarchical scheme, which loosely resembles the structure and functionality of the nominal human central nervous system (CNS). Active and passive safety mechanisms are considered to be central aspects underlying all of P/O design and control, and are shown to be critical for regulatory approval of such devices for real-world use.The works discussed herein provide evidence that, while we are getting ever closer, significant challenges still exist for the development of controllers for portable powered P/O devices that can seamlessly integrate with the user's neuromusculoskeletal system and are practical for use in locomotive ADL.
Collapse
Affiliation(s)
- Michael R Tucker
- />Rehabilitation Engineering Lab, Department of Health Sciences and Technology, ETH Zurich, Zürich, Switzerland
| | - Jeremy Olivier
- />Robotic Systems Laboratory, Institute for Microengineering, EPFL, Lausanne, Switzerland
| | - Anna Pagel
- />Sensory Motor Systems Lab, Department of Health Sciences and Technology, ETH Zurich, Zürich, Switzerland
| | - Hannes Bleuler
- />Robotic Systems Laboratory, Institute for Microengineering, EPFL, Lausanne, Switzerland
| | - Mohamed Bouri
- />Robotic Systems Laboratory, Institute for Microengineering, EPFL, Lausanne, Switzerland
| | - Olivier Lambercy
- />Rehabilitation Engineering Lab, Department of Health Sciences and Technology, ETH Zurich, Zürich, Switzerland
| | - José del R Millán
- />Defitech Chair in Non-Invasive Brain-Machine Interface, Center for Neuroprosthetics, Institute of Bioengineering, EPFL, Lausanne, Switzerland
| | - Robert Riener
- />Sensory Motor Systems Lab, Department of Health Sciences and Technology, ETH Zurich, Zürich, Switzerland
- />Faculty of Medicine, Spinal Cord Injury Center, Balgrist University Hospital, University of Zurich, Zürich, Switzerland
| | - Heike Vallery
- />Sensory Motor Systems Lab, Department of Health Sciences and Technology, ETH Zurich, Zürich, Switzerland
- />Faculty of Mechanical, Maritime and Materials Engineering, Department of BioMechanical Engineering, Delft University of Technology, Delft, The Netherlands
| | - Roger Gassert
- />Rehabilitation Engineering Lab, Department of Health Sciences and Technology, ETH Zurich, Zürich, Switzerland
| |
Collapse
|
20
|
Chang SR, Kobetic R, Audu ML, Quinn RD, Triolo RJ. Powered Lower-Limb Exoskeletons to Restore Gait for Individuals with Paraplegia - a Review. CASE ORTHOPAEDIC JOURNAL 2015; 12:75-80. [PMID: 28004009 PMCID: PMC5166705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Individuals with paraplegia due to spinal cord injury rank restoration of walking high on the list of priorities to improving their quality of life. Powered lower-limb exoskeleton technology provides the ability to restore standing up, sitting down, and walking movements for individuals with paraplegia. The robotic exoskeletons generally have electrical motors located at the hip and knee joint centers, which move the wearers' lower limbs through the appropriate range of motion for gait according to control systems using either trajectory control or impedance control. Users of exoskeletons are able to walk at average gait speeds of 0.26 m/s and distances ranging between 121-171 m. However, the achieved gait speeds and distances fall short of those required for full community ambulation (0.8 m/s and at least 230 m), restricting use of the devices to limited community use with stand-by assist or supervised rehabilitation settings. Improvement in the gait speed and distance may be achievable by combining a specially designed powered exoskeleton with neuromuscular stimulation technologies resulting in a hybrid system that fully engages the user and achieves the necessary requirements to ambulate in the community environment with benefits of muscle contraction.
Collapse
Affiliation(s)
- Sarah R Chang
- Advanced Platform Technology Center, Louis Stokes Cleveland Department of Veterans Affairs Medical Center; Department of Biomedical Engineering, Case Western Reserve University
| | - Rudi Kobetic
- Advanced Platform Technology Center, Louis Stokes Cleveland Department of Veterans Affairs Medical Center
| | - Musa L Audu
- Advanced Platform Technology Center, Louis Stokes Cleveland Department of Veterans Affairs Medical Center
| | - Roger D Quinn
- Advanced Platform Technology Center, Louis Stokes Cleveland Department of Veterans Affairs Medical Center; Departments of Mechanical Engineering and Aerospace Engineering, Case Western Reserve University
| | - Ronald J Triolo
- Advanced Platform Technology Center, Louis Stokes Cleveland Department of Veterans Affairs Medical Center; Department of Biomedical Engineering, Case Western Reserve University; Department of Orthopaedics, Case Western Reserve University
| |
Collapse
|