1
|
Lazazzera R, Laguna P, Gil E, Carrault G. Proposal for a Home Sleep Monitoring Platform Employing a Smart Glove. SENSORS 2021; 21:s21237976. [PMID: 34883979 PMCID: PMC8659764 DOI: 10.3390/s21237976] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Revised: 11/21/2021] [Accepted: 11/23/2021] [Indexed: 11/16/2022]
Abstract
The present paper proposes the design of a sleep monitoring platform. It consists of an entire sleep monitoring system based on a smart glove sensor called UpNEA worn during the night for signals acquisition, a mobile application, and a remote server called AeneA for cloud computing. UpNEA acquires a 3-axis accelerometer signal, a photoplethysmography (PPG), and a peripheral oxygen saturation (SpO2) signal from the index finger. Overnight recordings are sent from the hardware to a mobile application and then transferred to AeneA. After cloud computing, the results are shown in a web application, accessible for the user and the clinician. The AeneA sleep monitoring activity performs different tasks: sleep stages classification and oxygen desaturation assessment; heart rate and respiration rate estimation; tachycardia, bradycardia, atrial fibrillation, and premature ventricular contraction detection; and apnea and hypopnea identification and classification. The PPG breathing rate estimation algorithm showed an absolute median error of 0.5 breaths per minute for the 32 s window and 0.2 for the 64 s window. The apnea and hypopnea detection algorithm showed an accuracy (Acc) of 75.1%, by windowing the PPG in one-minute segments. The classification task revealed 92.6% Acc in separating central from obstructive apnea, 83.7% in separating central apnea from central hypopnea and 82.7% in separating obstructive apnea from obstructive hypopnea. The novelty of the integrated algorithms and the top-notch cloud computing products deployed, encourage the production of the proposed solution for home sleep monitoring.
Collapse
Affiliation(s)
- Remo Lazazzera
- Laboratoire Traitement du Signal et de l’Image (LTSI-Inserm UMR 1099), Université de Rennes 1, 35000 Rennes, France;
| | - Pablo Laguna
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, I3A, IIS Aragón, University of Zaragoza, and with the CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 50018 Zaragoza, Spain; (P.L.); (E.G.)
| | - Eduardo Gil
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, I3A, IIS Aragón, University of Zaragoza, and with the CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 50018 Zaragoza, Spain; (P.L.); (E.G.)
| | - Guy Carrault
- Laboratoire Traitement du Signal et de l’Image (LTSI-Inserm UMR 1099), Université de Rennes 1, 35000 Rennes, France;
- Correspondence:
| |
Collapse
|
2
|
Vila G, Godin C, Charbonnier S, Campagne A. Real-Time Quality Index to Control Data Loss in Real-Life Cardiac Monitoring Applications. SENSORS 2021; 21:s21165357. [PMID: 34450799 PMCID: PMC8400129 DOI: 10.3390/s21165357] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 07/22/2021] [Accepted: 08/03/2021] [Indexed: 01/02/2023]
Abstract
Wearable cardiac sensors pave the way for advanced cardiac monitoring applications based on heart rate variability (HRV). In real-life settings, heart rate (HR) measurements are subject to motion artifacts that may lead to frequent data loss (missing samples in the HR signal), especially for commercial devices based on photoplethysmography (PPG). The current study had two main goals: (i) to provide a white-box quality index that estimates the amount of missing samples in any piece of HR signal; and (ii) to quantify the impact of data loss on feature extraction in a PPG-based HR signal. This was done by comparing real-life recordings from commercial sensors featuring both PPG (Empatica E4) and ECG (Zephyr BioHarness 3). After an outlier rejection process, our quality index was used to isolate portions of ECG-based HR signals that could be used as benchmark, to validate the output of Empatica E4 at the signal level and at the feature level. Our results showed high accuracy in estimating the mean HR (median error: 3.2%), poor accuracy for short-term HRV features (e.g., median error: 64% for high-frequency power), and mild accuracy for longer-term HRV features (e.g., median error: 25% for low-frequency power). These levels of errors could be reduced by using our quality index to identify time windows with few or no data loss (median errors: 0.0%, 27%, and 6.4% respectively, when no sample was missing). This quality index should be useful in future work to extract reliable cardiac features in real-life measurements, or to conduct a field validation study on wearable cardiac sensors.
Collapse
Affiliation(s)
- Gaël Vila
- Univ. Grenoble Alpes, CEA, Leti, F-38000 Grenoble, France;
- Gipsa-Lab, Univ. Grenoble Alpes & CNRS, F-38402 Grenoble, France;
| | - Christelle Godin
- Univ. Grenoble Alpes, CEA, Leti, F-38000 Grenoble, France;
- Correspondence: ; Tel.: +33-438-784-067
| | | | - Aurélie Campagne
- LPNC UMR 5105, Univ. Grenoble Alpes & CNRS, F-38040 Grenoble, France;
| |
Collapse
|
3
|
Izdrui DR, Hagan MG, Geman O, Postolache O, Alexandre R. Smart sensing systems for in-home health status and emotional well-being monitoring during COVID-19. BIOMEDICAL ENGINEERING TOOLS FOR MANAGEMENT FOR PATIENTS WITH COVID-19 2021. [PMCID: PMC8192308 DOI: 10.1016/b978-0-12-824473-9.00003-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
The COVID-19 pandemic has restricted the mobility of the population. The experts propose several solutions in order to decrease the number of patients infected with this new virus by treating and monitoring them within the comfort of their own home. A new direction for the research has been identified including healthcare smart sensing systems which can provide medical diagnoses, surveillance, and treatment partially or totally remotely. The field of wearable, smart sensing solutions is becoming nowadays a widely accepted solution characterized also by the increased level of acceptance with regard to home health status monitoring. Pervasive computing and wearable solutions are frequently a topic included in current projects and are expected in new future developments, particularly in the pandemic context which forces people to remain mostly at home. As part of wearable devices the design of textiles, computer science, and smart materials are the three major development directions. The latest developments associated with the monitoring of health status and emotional well-being are presented and discussed in this chapter.
Collapse
|
4
|
An Energy-Efficient Algorithm for Wearable Electrocardiogram Signal Processing in Ubiquitous Healthcare Applications. SENSORS 2018; 18:s18030923. [PMID: 29558433 PMCID: PMC5876517 DOI: 10.3390/s18030923] [Citation(s) in RCA: 67] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2018] [Revised: 02/24/2018] [Accepted: 02/26/2018] [Indexed: 02/05/2023]
Abstract
Rapid progress and emerging trends in miniaturized medical devices have enabled the un-obtrusive monitoring of physiological signals and daily activities of everyone’s life in a prominent and pervasive manner. Due to the power-constrained nature of conventional wearable sensor devices during ubiquitous sensing (US), energy-efficiency has become one of the highly demanding and debatable issues in healthcare. This paper develops a single chip-based wearable wireless electrocardiogram (ECG) monitoring system by adopting analog front end (AFE) chip model ADS1292R from Texas Instruments. The developed chip collects real-time ECG data with two adopted channels for continuous monitoring of human heart activity. Then, these two channels and the AFE are built into a right leg drive right leg drive (RLD) driver circuit with lead-off detection and medical graded test signal. Human ECG data was collected at 60 beats per minute (BPM) to 120 BPM with 60 Hz noise and considered throughout the experimental set-up. Moreover, notch filter (cutoff frequency 60 Hz), high-pass filter (cutoff frequency 0.67 Hz), and low-pass filter (cutoff frequency 100 Hz) with cut-off frequencies of 60 Hz, 0.67 Hz, and 100 Hz, respectively, were designed with bilinear transformation for rectifying the power-line noise and artifacts while extracting real-time ECG signals. Finally, a transmission power control-based energy-efficient (ETPC) algorithm is proposed, implemented on the hardware and then compared with the several conventional TPC methods. Experimental results reveal that our developed chip collects real-time ECG data efficiently, and the proposed ETPC algorithm achieves higher energy savings of 35.5% with a slightly larger packet loss ratio (PLR) as compared to conventional TPC (e.g., constant TPC, Gao’s, and Xiao’s methods).
Collapse
|
5
|
Charlton PH, Birrenkott DA, Bonnici T, Pimentel MAF, Johnson AEW, Alastruey J, Tarassenko L, Watkinson PJ, Beale R, Clifton DA. Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review. IEEE Rev Biomed Eng 2017; 11:2-20. [PMID: 29990026 PMCID: PMC7612521 DOI: 10.1109/rbme.2017.2763681] [Citation(s) in RCA: 127] [Impact Index Per Article: 18.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Breathing rate (BR) is a key physiological parameter used in a range of clinical settings. Despite its diagnostic and prognostic value, it is still widely measured by counting breaths manually. A plethora of algorithms have been proposed to estimate BR from the electrocardiogram (ECG) and pulse oximetry (photoplethysmogram, PPG) signals. These BR algorithms provide opportunity for automated, electronic, and unobtrusive measurement of BR in both healthcare and fitness monitoring. This paper presents a review of the literature on BR estimation from the ECG and PPG. First, the structure of BR algorithms and the mathematical techniques used at each stage are described. Second, the experimental methodologies that have been used to assess the performance of BR algorithms are reviewed, and a methodological framework for the assessment of BR algorithms is presented. Third, we outline the most pressing directions for future research, including the steps required to use BR algorithms in wearable sensors, remote video monitoring, and clinical practice.
Collapse
Affiliation(s)
- Peter H. Charlton
- Department of Biomedical Engineering, King’s College London, London SE1 7EH, U.K., and also with the Department of Engineering Science, University of Oxford, Oxford OX3 7DQ, U.K
| | - Drew A. Birrenkott
- Department of Engineering Science, University of Oxford, Oxford OX3 7DQ, U.K
| | - Timothy Bonnici
- Nuffield Department of Medicine, University of Oxford, Oxford OX3 9DU, U.K., and also with the Department of Asthma, Allergy, and Lung Biology, King’s College London, London SE1 7EH, U.K
| | | | - Alistair E. W. Johnson
- Laboratory for Computational Physiology, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| | - Jordi Alastruey
- Department of Biomedical Engineering, King’s College London, London SE1 7EH, U.K
| | - Lionel Tarassenko
- Department of Engineering Science, University of Oxford, Oxford OX3 7DQ, U.K
| | - Peter J. Watkinson
- Kadoorie Centre for Critical Care Research and Education, Oxford University Hospitals NHS Foundation Trust, Oxford OX3 9DU, U.K
| | - Richard Beale
- Department of Asthma, Allergy and Lung Biology, King’s College London, London SE1 7EH, U.K
| | - David A. Clifton
- Department of Engineering Science, University of Oxford, Oxford OX3 7DQ, U.K
| |
Collapse
|
6
|
Derivation of respiration rate from ambulatory ECG and PPG using Ensemble Empirical Mode Decomposition: Comparison and fusion. Comput Biol Med 2017; 81:45-54. [DOI: 10.1016/j.compbiomed.2016.12.005] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2016] [Revised: 11/23/2016] [Accepted: 12/06/2016] [Indexed: 11/23/2022]
|
7
|
Hafs T, Bennacer L, Boughazi M, Nait‐Ali A. Empirical mode decomposition for online handwritten signature verification. IET BIOMETRICS 2016. [DOI: 10.1049/iet-bmt.2014.0041] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Affiliation(s)
- Toufik Hafs
- Electronics Department, Faculty of Engineering SciencesL.E.R.I.C.A. University of Badji MokhtarP. Box 1223000AnnabaAlgeria
| | - Layachi Bennacer
- Electronics Department, Faculty of Engineering SciencesL.E.R.I.C.A. University of Badji MokhtarP. Box 1223000AnnabaAlgeria
| | - Mohamed Boughazi
- Electronics Department, Faculty of Engineering SciencesL.E.R.I.C.A. University of Badji MokhtarP. Box 1223000AnnabaAlgeria
| | - Amine Nait‐Ali
- Faculty of Science and TechnologyLISSI, University of Paris 12 Val de Marne61 Avenue du Général de Gaulle94010CréteilFrance
| |
Collapse
|