• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4623447)   Today's Articles (3465)   Subscriber (49409)
For: Kirchsteiger H, Zaccarian L, Renard E, del Re L. A novel online recalibration strategy for continuous glucose measurement sensors employing LMI techniques. Annu Int Conf IEEE Eng Med Biol Soc 2015;2013:3921-4. [PMID: 24110589 DOI: 10.1109/embc.2013.6610402] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Number Cited by Other Article(s)
1
Acciaroli G, Vettoretti M, Facchinetti A, Sparacino G. Calibration of Minimally Invasive Continuous Glucose Monitoring Sensors: State-of-The-Art and Current Perspectives. BIOSENSORS 2018;8:E24. [PMID: 29534053 PMCID: PMC5872072 DOI: 10.3390/bios8010024] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/20/2018] [Revised: 03/08/2018] [Accepted: 03/09/2018] [Indexed: 12/26/2022]
2
Acciaroli G, Vettoretti M, Facchinetti A, Sparacino G, Cobelli C. Reduction of Blood Glucose Measurements to Calibrate Subcutaneous Glucose Sensors: A Bayesian Multiday Framework. IEEE Trans Biomed Eng 2017;65:587-595. [PMID: 28541194 DOI: 10.1109/tbme.2017.2706974] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
3
Vettoretti M, Facchinetti A, Del Favero S, Sparacino G, Cobelli C. Online Calibration of Glucose Sensors From the Measured Current by a Time-Varying Calibration Function and Bayesian Priors. IEEE Trans Biomed Eng 2015;63:1631-41. [PMID: 25915955 DOI: 10.1109/tbme.2015.2426217] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
4
Kirchsteiger H, Zaccarian L, Renard E, del Re L. LMI-Based Approaches for the Calibration of Continuous Glucose Measurement Sensors. IEEE J Biomed Health Inform 2014;19:1697-706. [PMID: 25095270 DOI: 10.1109/jbhi.2014.2341703] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA