Estrada-Petrocelli L, Torres A, Sarlabous L, Rafols-de-Urquia M, Ye-Lin Y, Prats-Boluda G, Jane R, Garcia-Casado J. Evaluation of Respiratory Muscle Activity by Means of Concentric Ring Electrodes. IEEE Trans Biomed Eng 2020; 68:1005-1014. [PMID: 32746073 DOI: 10.1109/tbme.2020.3012385] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Surface electromyography (sEMG) can be used for the evaluation of respiratory muscle activity. Recording sEMG involves the use of surface electrodes in a bipolar configuration. However, electrocardiographic (ECG) interference and electrode orientation represent considerable drawbacks to bipolar acquisition. As an alternative, concentric ring electrodes (CREs) can be used for sEMG acquisition and offer great potential for the evaluation of respiratory muscle activity due to their enhanced spatial resolution and simple placement protocol, which does not depend on muscle fiber orientation. The aim of this work was to analyze the performance of CREs during respiratory sEMG acquisitions. Respiratory muscle sEMG was applied to the diaphragm and sternocleidomastoid muscles using a bipolar and a CRE configuration. Thirty-two subjects underwent four inspiratory load spontaneous breathing tests which was repeated after interchanging the electrode positions. We calculated parameters such as (1) spectral power and (2) median frequency during inspiration, and power ratios of inspiratory sEMG without ECG in relation to (3) basal sEMG without ECG (Rins/noise), (4) basal sEMG with ECG (Rins/cardio) and (5) expiratory sEMG without ECG (Rins/exp). Spectral power, Rins/noise and Rins/cardio increased with the inspiratory load. Significantly higher values (p < 0.05) of Rins/cardio and significantly higher median frequencies were obtained for CREs. Rins/noise and Rins/exp were higher for the bipolar configuration only in diaphragm sEMG recordings, whereas no significant differences were found in the sternocleidomastoid recordings. Our results suggest that the evaluation of respiratory muscle activity by means of sEMG can benefit from the remarkably reduced influence of cardiac activity, the enhanced detection of the shift in frequency content and the axial isotropy of CREs which facilitates its placement.
Collapse
|
2
|
Sarlabous L, Estrada L, Cerezo-Hernández A, V. D. Leest S, Torres A, Jané R, Duiverman M, Garde A. Electromyography-Based Respiratory Onset Detection in COPD Patients on Non-Invasive Mechanical Ventilation. ENTROPY 2019; 21:e21030258. [PMID: 33266973 PMCID: PMC7514739 DOI: 10.3390/e21030258] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Revised: 02/22/2019] [Accepted: 02/28/2019] [Indexed: 11/16/2022]
Abstract
To optimize long-term nocturnal non-invasive ventilation in patients with chronic obstructive pulmonary disease, surface diaphragm electromyography (EMGdi) might be helpful to detect patient-ventilator asynchrony. However, visual analysis is labor-intensive and EMGdi is heavily corrupted by electrocardiographic (ECG) activity. Therefore, we developed an automatic method to detect inspiratory onset from EMGdi envelope using fixed sample entropy (fSE) and a dynamic threshold based on kernel density estimation (KDE). Moreover, we combined fSE with adaptive filtering techniques to reduce ECG interference and improve onset detection. The performance of EMGdi envelopes extracted by applying fSE and fSE with adaptive filtering was compared to the root mean square (RMS)-based envelope provided by the EMG acquisition device. Automatic onset detection accuracy, using these three envelopes, was evaluated through the root mean square error (RMSE) between the automatic and mean visual onsets (made by two observers). The fSE-based method provided lower RMSE, which was reduced from 298 ms to 264 ms when combined with adaptive filtering, compared to 301 ms provided by the RMS-based method. The RMSE was negatively correlated with the proposed EMGdi quality indices. Following further validation, fSE with KDE, combined with adaptive filtering when dealing with low quality EMGdi, indicates promise for detecting the neural onset of respiratory drive.
Collapse
Affiliation(s)
- Leonardo Sarlabous
- Biomedical Signal Processing and Interpretation, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), 08028 Barcelona, Spain
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)—Barcelona Tech, 08028 Barcelona, Spain
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 08028 Barcelona, Spain
| | - Luis Estrada
- Biomedical Signal Processing and Interpretation, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), 08028 Barcelona, Spain
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)—Barcelona Tech, 08028 Barcelona, Spain
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 08028 Barcelona, Spain
| | - Ana Cerezo-Hernández
- Department of Pulmonology, Rio Hortega University Hospital, 47012 Valladolid, Spain
- Department of Pulmonary Diseases/Home mechanical Ventilation, University of Groningen, University Medical Center Groningen, 9713 Groningen, The Netherlands
| | - Sietske V. D. Leest
- Biomedical Signals and Systems Group, Faculty of Electrical Engineering, Mathematics & Computer Science, University of Twente, 7500 Enschede, The Netherlands
| | - Abel Torres
- Biomedical Signal Processing and Interpretation, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), 08028 Barcelona, Spain
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)—Barcelona Tech, 08028 Barcelona, Spain
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 08028 Barcelona, Spain
| | - Raimon Jané
- Biomedical Signal Processing and Interpretation, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), 08028 Barcelona, Spain
- Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)—Barcelona Tech, 08028 Barcelona, Spain
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 08028 Barcelona, Spain
| | - Marieke Duiverman
- Department of Pulmonary Diseases/Home mechanical Ventilation, University of Groningen, University Medical Center Groningen, 9713 Groningen, The Netherlands
- Groningen Research Institute of Asthma and COPD (GRIAC), University of Groningen, 9712 Groningen, The Netherlands
| | - Ainara Garde
- Biomedical Signals and Systems Group, Faculty of Electrical Engineering, Mathematics & Computer Science, University of Twente, 7500 Enschede, The Netherlands
- Correspondence: ; Tel.: +31-642-526-154
| |
Collapse
|