1
|
Krönke M, Eilers C, Dimova D, Köhler M, Buschner G, Schweiger L, Konstantinidou L, Makowski M, Nagarajah J, Navab N, Weber W, Wendler T. Tracked 3D ultrasound and deep neural network-based thyroid segmentation reduce interobserver variability in thyroid volumetry. PLoS One 2022; 17:e0268550. [PMID: 35905038 PMCID: PMC9337648 DOI: 10.1371/journal.pone.0268550] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Accepted: 05/02/2022] [Indexed: 11/29/2022] Open
Abstract
Thyroid volumetry is crucial in the diagnosis, treatment, and monitoring of thyroid diseases. However, conventional thyroid volumetry with 2D ultrasound is highly operator-dependent. This study compares 2D and tracked 3D ultrasound with an automatic thyroid segmentation based on a deep neural network regarding inter- and intraobserver variability, time, and accuracy. Volume reference was MRI. 28 healthy volunteers (24—50 a) were scanned with 2D and 3D ultrasound (and by MRI) by three physicians (MD 1, 2, 3) with different experience levels (6, 4, and 1 a). In the 2D scans, the thyroid lobe volumes were calculated with the ellipsoid formula. A convolutional deep neural network (CNN) automatically segmented the 3D thyroid lobes. 26, 6, and 6 random lobe scans were used for training, validation, and testing, respectively. On MRI (T1 VIBE sequence) the thyroid was manually segmented by an experienced MD. MRI thyroid volumes ranged from 2.8 to 16.7ml (mean 7.4, SD 3.05). The CNN was trained to obtain an average Dice score of 0.94. The interobserver variability comparing two MDs showed mean differences for 2D and 3D respectively of 0.58 to 0.52ml (MD1 vs. 2), −1.33 to −0.17ml (MD1 vs. 3) and −1.89 to −0.70ml (MD2 vs. 3). Paired samples t-tests showed significant differences for 2D (p = .140, p = .002 and p = .002) and none for 3D (p = .176, p = .722 and p = .057). Intraobsever variability was similar for 2D and 3D ultrasound. Comparison of ultrasound volumes and MRI volumes showed a significant difference for the 2D volumetry of all MDs (p = .002, p = .009, p <.001), and no significant difference for 3D ultrasound (p = .292, p = .686, p = 0.091). Acquisition time was significantly shorter for 3D ultrasound. Tracked 3D ultrasound combined with a CNN segmentation significantly reduces interobserver variability in thyroid volumetry and increases the accuracy of the measurements with shorter acquisition times.
Collapse
Affiliation(s)
- Markus Krönke
- Department of Radiology and Nuclear Medicine, German Heart Center, Technical University of Munich, Munich, Germany
- Department of Nuclear Medicine, School of Medicine, Technical University of Munich, Munich, Germany
| | - Christine Eilers
- Chair for Computer Aided Medical Procedures and Augmented Reality, Department of Computer Science, Technical University of Munich, Garching Near Munich, Germany
- * E-mail:
| | - Desislava Dimova
- Chair for Computer Aided Medical Procedures and Augmented Reality, Department of Computer Science, Technical University of Munich, Garching Near Munich, Germany
| | - Melanie Köhler
- Chair for Computer Aided Medical Procedures and Augmented Reality, Department of Computer Science, Technical University of Munich, Garching Near Munich, Germany
- Medical Faculty, Technical University of Munich, Munich, Germany
| | - Gabriel Buschner
- Department of Nuclear Medicine, School of Medicine, Technical University of Munich, Munich, Germany
| | - Lilit Schweiger
- Department of Nuclear Medicine, School of Medicine, Technical University of Munich, Munich, Germany
| | - Lemonia Konstantinidou
- Chair for Computer Aided Medical Procedures and Augmented Reality, Department of Computer Science, Technical University of Munich, Garching Near Munich, Germany
| | - Marcus Makowski
- Department of Radiology, School of Medicine, Technical University of Munich, Munich, Germany
| | - James Nagarajah
- Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Nassir Navab
- Chair for Computer Aided Medical Procedures and Augmented Reality, Department of Computer Science, Technical University of Munich, Garching Near Munich, Germany
- Chair for Computer Aided Medical Procedures, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, United States of America
| | - Wolfgang Weber
- Department of Nuclear Medicine, School of Medicine, Technical University of Munich, Munich, Germany
| | - Thomas Wendler
- Chair for Computer Aided Medical Procedures and Augmented Reality, Department of Computer Science, Technical University of Munich, Garching Near Munich, Germany
| |
Collapse
|