1
|
Mayrovitz HN. Assessment of Intraday Variations in Skin Indentation Resistance. Cureus 2024; 16:e65590. [PMID: 39077674 PMCID: PMC11285697 DOI: 10.7759/cureus.65590] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2024] [Accepted: 07/28/2024] [Indexed: 07/31/2024] Open
Abstract
INTRODUCTION Information about the mechanical properties of skin and their changes with age and other conditions is important to help characterize skin physiology and pathological changes. One method to obtain this information is to measure the force required to indent the skin to a specified indentation depth (FORCE). This process measures the tissue's resistance to indentation or its compressibility and is related to the tissue's elastic modulus. Since such measurements are made in clinical and other settings at various times of day (TOD), it is useful to estimate the extent of intraday variations in FORCE that may be expected. This report focuses on this issue. METHOD FORCE was self-measured on the volar forearm, 5 cm distal to the antecubital fossa, every two hours from 08:00 to 24:00 hours on two consecutive days by 12 medical students (six females and six males) who were trained in the measurement process using an indentation device (SkinFibroMeter). Variability in FORCE versus TOD was analyzed using the nonparametric Friedman test and differences between genders by the nonparametric Wilcoxon test. Differences between the first day (day 1) and the second day (day 2) were tested at each TOD. The whole-body fat percentage (FAT%) and water percentage (H2O%) were determined for each participant via bioimpedance measurements at 50 KHz. RESULTS The age and BMI of the combined group (mean ± SD) were 24.5 ± 1.5 years and 23.2 ± 3.3 kg/m2. The overall average FORCE (mean ± SD) for the day over the 16 hours was 84.1 ± 22.7 mN and for day 2, it was 83.4 ± 28.5 mN with no significant difference between day 1 and day 2. For females, the overall two-day average FORCE (mean ± SD) over the 16 hours was 81.8 ± 20.3 mN and for males, it was 85.7 ± 30.1 mN with no significant difference between them (p = 0.271). Overall, there was no statistically significant difference in FORCE among TOD (p = 0.568). FORCE was not correlated with either FAT%, HTO%, or BMI. CONCLUSION The findings indicate no statistically significant variation in indentation force in females, males, or combined concerning the TOD of the measurement or differences between consecutive days at corresponding times. This suggests that whether such measurements are done in a research setting or within a clinic, they can be done at various TOD with minimal expected variation for a given subject. However, an extension of these findings to persons with skin conditions or ages not herein evaluated must await further study.
Collapse
Affiliation(s)
- Harvey N Mayrovitz
- Medical Education, Nova Southeastern University Dr. Kiran C. Patel College of Allopathic Medicine, Davie, USA
| |
Collapse
|
2
|
Westphal JA, Bryan AE, Krutko M, Esfandiari L, Schutte SC, Harris GM. Innervation of an Ultrasound-Mediated PVDF-TrFE Scaffold for Skin-Tissue Engineering. Biomimetics (Basel) 2023; 9:2. [PMID: 38275450 PMCID: PMC11154284 DOI: 10.3390/biomimetics9010002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 12/05/2023] [Accepted: 12/18/2023] [Indexed: 01/27/2024] Open
Abstract
In this work, electrospun polyvinylidene-trifluoroethylene (PVDF-TrFE) was utilized for its biocompatibility, mechanics, and piezoelectric properties to promote Schwann cell (SC) elongation and sensory neuron (SN) extension. PVDF-TrFE electrospun scaffolds were characterized over a variety of electrospinning parameters (1, 2, and 3 h aligned and unaligned electrospun fibers) to determine ideal thickness, porosity, and tensile strength for use as an engineered skin tissue. PVDF-TrFE was electrically activated through mechanical deformation using low-intensity pulsed ultrasound (LIPUS) waves as a non-invasive means to trigger piezoelectric properties of the scaffold and deliver electric potential to cells. Using this therapeutic modality, neurite integration in tissue-engineered skin substitutes (TESSs) was quantified including neurite alignment, elongation, and vertical perforation into PVDF-TrFE scaffolds. Results show LIPUS stimulation promoted cell alignment on aligned scaffolds. Further, stimulation significantly increased SC elongation and SN extension separately and in coculture on aligned scaffolds but significantly decreased elongation and extension on unaligned scaffolds. This was also seen in cell perforation depth analysis into scaffolds which indicated LIPUS enhanced perforation of SCs, SNs, and cocultures on scaffolds. Taken together, this work demonstrates the immense potential for non-invasive electric stimulation of an in vitro tissue-engineered-skin model.
Collapse
Affiliation(s)
- Jennifer A. Westphal
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH 45221, USA; (J.A.W.); (M.K.); (L.E.); (S.C.S.)
| | - Andrew E. Bryan
- Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, OH 45221, USA;
| | - Maksym Krutko
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH 45221, USA; (J.A.W.); (M.K.); (L.E.); (S.C.S.)
| | - Leyla Esfandiari
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH 45221, USA; (J.A.W.); (M.K.); (L.E.); (S.C.S.)
- Department of Environmental and Public Health Sciences, University of Cincinnati, Cincinnati, OH 45267, USA
- Department of Electrical and Computer Science, University of Cincinnati, Cincinnati, OH 45221, USA
| | - Stacey C. Schutte
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH 45221, USA; (J.A.W.); (M.K.); (L.E.); (S.C.S.)
| | - Greg M. Harris
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH 45221, USA; (J.A.W.); (M.K.); (L.E.); (S.C.S.)
- Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, OH 45221, USA;
- Neuroscience Graduate Program, University of Cincinnati College of Medicine, Cincinnati, OH 45221, USA
| |
Collapse
|
3
|
Mesoscopic Monitoring of Human Skin Explants Viscoelastic Properties. COSMETICS 2023. [DOI: 10.3390/cosmetics10010013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
Abstract
The investigation of the mechanical properties of skin is of great interest for monitoring physiological and pathological changes in the cutaneous barrier function for dermatological and cosmetic issues. Skin constitutes a complex tissue because of its multi-layered organisation. From a rheological point of view, it can be considered to be a soft tissue with viscoelastic properties. In order to characterise ex vivo mechanical properties of skin on the mesoscopic scale, a biosensor including a thickness shear mode transducer (TSM) in contact with a skin explant was used. A specific experimental set-up was developed to monitor continuously and in real-time human skin explants, including the dermis and the epidermis. These were kept alive for up to 8 days. Skin viscoelastic evolutions can be quantified with a multi-frequency impedance measurement (from 5 MHz to 45 MHz) combined with a dedicated fractional calculus model. Two relevant parameters for the non-destructive mesoscopic characterisation of skin explants were extracted: the structural parameter αapp and the apparent viscosity ηapp. In this study, the validity of the biosensor, including repeatability and viability, was controlled. A typical signature of the viscoelastic evolutions of the different cutaneous layers was identified. Finally, monitoring was carried out on stripped explants mimicking a weakened barrier function.
Collapse
|
4
|
Kirby MA, Tang P, Liou HC, Kuriakose M, Pitre JJ, Pham TN, Ettinger RE, Wang RK, O'Donnell M, Pelivanov I. Probing elastic anisotropy of human skin in vivo with light using non-contact acoustic micro-tapping OCE and polarization sensitive OCT. Sci Rep 2022; 12:3963. [PMID: 35273250 PMCID: PMC8913799 DOI: 10.1038/s41598-022-07775-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Accepted: 02/24/2022] [Indexed: 12/19/2022] Open
Abstract
Skin broadly protects the human body from undesired factors such as ultraviolet radiation and abrasion and helps conserve body temperature and hydration. Skin's elasticity and its level of anisotropy are key to its aesthetics and function. Currently, however, treatment success is often speculative and subjective, and is rarely based on skin's elastic properties because there is no fast and accurate non-contact method for imaging of skin's elasticity. Here we report on a non-contact and non-invasive method to image and characterize skin's elastic anisotropy. It combines acoustic micro-tapping optical coherence elastography (AμT-OCE) with a nearly incompressible transversely isotropic (NITI) model to quantify skin's elastic moduli. In addition, skin sites were imaged with polarization sensitive optical coherence tomography (PS-OCT) to help define fiber orientation. Forearm skin areas were investigated in five volunteers. Results clearly demonstrate elastic anisotropy of skin in all subjects. AμT-OCE has distinct advantages over competitive techniques because it provides objective, quantitative characterization of skin's elasticity without contact, which opens the door for broad translation into clinical use. Finally, we demonstrate that a combination of multiple OCT modalities (structural OCT, OCT angiography, PS-OCT and AμT-OCE) may provide rich information about skin and can be used to characterize scar.
Collapse
Affiliation(s)
- Mitchell A Kirby
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Peijun Tang
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Hong-Cin Liou
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Maju Kuriakose
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - John J Pitre
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Tam N Pham
- Harborview Medical Center, University of Washington, Seattle, WA, USA
| | | | - Ruikang K Wang
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Matthew O'Donnell
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Ivan Pelivanov
- Department of Bioengineering, University of Washington, Seattle, WA, USA.
| |
Collapse
|
5
|
Dementyev A, Jitosho R, Paradiso JA. Mechanical Imaging of Soft Tissues With Miniature Climbing Robots. IEEE Trans Biomed Eng 2021; 68:3142-3150. [PMID: 33798064 DOI: 10.1109/tbme.2021.3070585] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Systematically mapping the mechanical properties of skin and tissue is useful for biomechanics research and disease diagnostics. For example, later stage breast cancer and lymphoma manifest themselves as hard nodes under the skin. Currently, mechanical measurements are done manually, with a sense of touch or a handheld tool. Manual measurements do not provide quantitative information and vary depending on the skill of the practitioner. Research shows that tactile sensors could be more sensitive than a hand. We propose a method that uses our previously developed skin-crawling robots to noninvasively test the mechanical properties of soft tissue. Robots are more systematic and repeatable than humans. Using the data collected with a cutomoter or indenter integrated into the miniature robot, we trained a convolutional neural network to classify the size and depth of the lumps. The classification works with 98.8% accuracy for cutometer and 99.6% for indenter for lump size with a diameter of 0 to 10 mm embedded in depth of 1 to 5 mm in a simulated tissue. We conducted a limited evaluation on a forearm, where the robot imaged dry skin with a cutometer. We hope to improve the ability to test tissues noninvasively, and ultimately provide better sensitivity and systematic data collection.
Collapse
|
6
|
Zhou K, Feng K, Li C, Huang Z. A Weighted Average Phase Velocity Inversion Model for Depth-Resolved Elasticity Evaluation in Human Skin In-Vivo. IEEE Trans Biomed Eng 2020; 68:1969-1977. [PMID: 33326373 DOI: 10.1109/tbme.2020.3045133] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE In current surface acoustic wave (SAW) elastography field, wavelength-depth inversion model is a straightforward and widely used inversion model for depth-resolved elasticity profile reconstruction. However, the elasticity directly evaluated from the wavelength-depth relationship is biased. Thus, a new inversion model, termed weighted average phase velocity (WAPV) inversion model, is proposed to provide depth-resolved Young's modulus estimate with better accuracy. METHODS The forward model for SAW phase velocity dispersion curve generation was derived from the numerical simulations of SAWs in layered materials, and inversion was implemented by matching the measured phase velocity dispersion curve to the one generated from the forward model using the least squares fitting. Three two-layer agar phantoms with different top-layer thicknesses and one three-layer agar phantom were tested to validate the proposed inversion model. Then the model was demonstrated on human skin at various sites (palm, forearm and back of hand) in-vivo. RESULTS In multi-layered agar phantoms, depth-resolved elasticity estimates provided by the model have a maximal total inversion error of 15.2% per sample after inversion error compensation. In in-vivo human skin, the quantified bulk Young's moduli (palm: 212 ± 78 kPa; forearm: 32 ± 11 kPa and back of hand: 29 ± 8 kPa) are comparable to the reference values in the literature. CONCLUSION The WAPV inversion model can provide accurate depth-resolved Young's modulus estimates in layered biological soft tissues. SIGNIFICANCE The proposed model can predict depth-resolved elasticity in layered biological soft tissues with a reasonable accuracy which traditional wavelength-depth inversion model cannot provide.
Collapse
|
7
|
Chanda A, Unnikrishnan V, Lackey K, Robbins J. Biofidelic conductive soft tissue surrogates. INT J POLYM MATER PO 2019. [DOI: 10.1080/00914037.2018.1552856] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Arnab Chanda
- Department of Aerospace Engineering, The University of Alabama, Tuscaloosa, Alabama, USA
| | - Vinu Unnikrishnan
- Department of Aerospace Engineering, The University of Alabama, Tuscaloosa, Alabama, USA
| | - Kim Lackey
- Department of Biological Sciences, The University of Alabama, Tuscaloosa, Alabama, USA
| | - Joseph Robbins
- Department of Mechanical Engineering, The University of Alabama, Tuscaloosa, Alabama, USA
| |
Collapse
|
8
|
Measuring relative vibrotactile spatial acuity: effects of tactor type, anchor points and tactile anisotropy. Exp Brain Res 2018; 236:3405-3416. [PMID: 30293171 PMCID: PMC6267683 DOI: 10.1007/s00221-018-5387-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2018] [Accepted: 09/27/2018] [Indexed: 12/26/2022]
Abstract
Vibrotactile displays can compensate for the loss of sensory function of people with permanent or temporary deficiencies in vision, hearing, or balance, and can augment the immersive experience in virtual environments for entertainment, or professional training. This wide range of potential applications highlights the need for research on the basic psychophysics of mechanisms underlying human vibrotactile perception. One key consideration when designing tactile displays is determining the minimal possible spacing between tactile motors (tactors), by empirically assessing the maximal throughput of the skin, or, in other words, vibrotactile spatial acuity. Notably, such estimates may vary by tactor type. We assessed vibrotactile spatial acuity in the lower thoracic region for three different tactor types, each mounted in a 4 × 4 array with center-to-center inter-tactor distances of 25 mm, 20 mm, and 10 mm. Seventeen participants performed a relative three-alternative forced-choice point localization task with successive tactor activation for both vertical and horizontal stimulus presentation. The results demonstrate that specific tactor characteristics (frequency, acceleration, contact area) significantly affect spatial acuity measurements, highlighting that the results of spatial acuity measurements may only apply to the specific tactors tested. Furthermore, our results reveal an anisotropy in vibrotactile perception, with higher spatial acuity for horizontal than for vertical stimulus presentation. The findings allow better understanding of vibrotactile spatial acuity and can be used for formulating guidelines for the design of tactile displays, such as regarding inter-tactor spacing, choice of tactor type, and direction of stimulus presentation.
Collapse
|
9
|
Chanda A. Biomechanical Modeling of Human Skin Tissue Surrogates. Biomimetics (Basel) 2018; 3:biomimetics3030018. [PMID: 31105240 PMCID: PMC6352690 DOI: 10.3390/biomimetics3030018] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2018] [Revised: 07/16/2018] [Accepted: 07/19/2018] [Indexed: 11/22/2022] Open
Abstract
Surrogates, which precisely simulate nonlinear mechanical properties of the human skin at different body sites, would be indispensable for biomechanical testing applications, such as estimating the accurate load response of skin implants and prosthetics to study the biomechanics of static and dynamic loading conditions on the skin, dermatological and sports injuries, and estimating the dynamic load response of lethal and nonlethal ballistics. To date, human skin surrogates have been developed mainly with materials, such as gelatin and polydimethylsiloxane (PDMS), based on assumption of simplified mechanical properties, such as an average elastic modulus (estimated through indentation tests), and Poisson’s ratio. In addition, pigskin and cowhides, which have widely varying mechanical properties, have been used to simulate human skin. In the current work, a novel elastomer-based material system is developed, which precisely mimics the nonlinear stress–stretch behavior, elastic modulus at high and low strains, and fracture strengths of the natural human skin at different body sites. The manufacturing and fabrication process of these skin surrogates are discussed, and mechanical testing results are presented.
Collapse
Affiliation(s)
- Arnab Chanda
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.
- Department of Aerospace Engineering and Mechanics, University of Alabama, Tuscaloosa, AL 35401, USA.
| |
Collapse
|
10
|
Zhou B, Zhang X. Comparison of five viscoelastic models for estimating viscoelastic parameters using ultrasound shear wave elastography. J Mech Behav Biomed Mater 2018; 85:109-116. [PMID: 29879581 DOI: 10.1016/j.jmbbm.2018.05.041] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Revised: 05/09/2018] [Accepted: 05/29/2018] [Indexed: 01/09/2023]
Abstract
The purpose of this study is to compare five viscoelastic models (Voigt, Maxwell, standard linear solid, spring-pot, and fractional Voigt models) for estimating viscoelastic properties based on ultrasound shear wave elastography measurements. We performed the forward problem analysis, the inverse problem analysis, and experiments. In the forward problem analysis, the shear wave speeds at different frequencies were calculated using the Voigt model for given shear elasticity and varying shear viscosity. In the inverse problem analysis, the viscoelastic parameters were estimated from the given wave speeds for the five viscoelastic models using the least-square regression. The experiment was performed in a tissue-mimicking phantom. A local harmonic vibration was generated via a mechanical shaker on the phantom at five frequencies (100, 150, 200, 250, and 300 Hz) and an ultrasound transducer was used to capture the tissue motion. Shear wave speed of the phantom was measured using the ultrasound shear wave elastography technique. The parameters for different viscoelastic models for the phantom were identified. For both analytical and experimental studies, ratios of storage to loss modulus as a function of excitation frequency for different viscoelastic models were calculated. We found that the Voigt and fractional Voigt models fit well with the shear wave speed - frequency and ratio of storage to loss modulus - frequency relationships both in analytical and experimental studies.
Collapse
Affiliation(s)
- Boran Zhou
- Department of Radiology, Mayo Clinic College of Medicine, 200 1st St SW, Rochester, MN 55905, USA
| | - Xiaoming Zhang
- Department of Radiology, Mayo Clinic College of Medicine, 200 1st St SW, Rochester, MN 55905, USA.
| |
Collapse
|
11
|
Parker MD, Jones LA, Hunter IW, Taberner AJ, Nash MP, Nielsen PMF. Multidirectional In Vivo Characterization of Skin Using Wiener Nonlinear Stochastic System Identification Techniques. J Biomech Eng 2017; 139:2571658. [PMID: 27760249 DOI: 10.1115/1.4034993] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2016] [Indexed: 11/08/2022]
Abstract
A triaxial force-sensitive microrobot was developed to dynamically perturb skin in multiple deformation modes, in vivo. Wiener static nonlinear identification was used to extract the linear dynamics and static nonlinearity of the force-displacement behavior of skin. Stochastic input forces were applied to the volar forearm and thenar eminence of the hand, producing probe tip perturbations in indentation and tangential extension. Wiener static nonlinear approaches reproduced the resulting displacements with variances accounted for (VAF) ranging 94-97%, indicating a good fit to the data. These approaches provided VAF improvements of 0.1-3.4% over linear models. Thenar eminence stiffness measures were approximately twice those measured on the forearm. Damping was shown to be significantly higher on the palm, whereas the perturbed mass typically was lower. Coefficients of variation (CVs) for nonlinear parameters were assessed within and across individuals. Individual CVs ranged from 2% to 11% for indentation and from 2% to 19% for extension. Stochastic perturbations with incrementally increasing mean amplitudes were applied to the same test areas. Differences between full-scale and incremental reduced-scale perturbations were investigated. Different incremental preloading schemes were investigated. However, no significant difference in parameters was found between different incremental preloading schemes. Incremental schemes provided depth-dependent estimates of stiffness and damping, ranging from 300 N/m and 2 Ns/m, respectively, at the surface to 5 kN/m and 50 Ns/m at greater depths. The device and techniques used in this research have potential applications in areas, such as evaluating skincare products, assessing skin hydration, or analyzing wound healing.
Collapse
Affiliation(s)
- Matthew D Parker
- Auckland Bioengineering Institute, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand e-mail:
| | - Lynette A Jones
- BioInstrumentation Laboratory, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 e-mail:
| | - Ian W Hunter
- BioInstrumentation Laboratory, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 e-mail:
| | - A J Taberner
- Department of Engineering Science, Auckland Bioengineering Institute, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand e-mail:
| | - M P Nash
- Department of Engineering Science, Auckland Bioengineering Institute, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand e-mail:
| | - P M F Nielsen
- Department of Engineering Science, Auckland Bioengineering Institute, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand e-mail:
| |
Collapse
|
12
|
Limbert G. Mathematical and computational modelling of skin biophysics: a review. Proc Math Phys Eng Sci 2017; 473:20170257. [PMID: 28804267 PMCID: PMC5549575 DOI: 10.1098/rspa.2017.0257] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2017] [Accepted: 06/21/2017] [Indexed: 01/05/2023] Open
Abstract
The objective of this paper is to provide a review on some aspects of the mathematical and computational modelling of skin biophysics, with special focus on constitutive theories based on nonlinear continuum mechanics from elasticity, through anelasticity, including growth, to thermoelasticity. Microstructural and phenomenological approaches combining imaging techniques are also discussed. Finally, recent research applications on skin wrinkles will be presented to highlight the potential of physics-based modelling of skin in tackling global challenges such as ageing of the population and the associated skin degradation, diseases and traumas.
Collapse
Affiliation(s)
- Georges Limbert
- National Centre for Advanced Tribology at Southampton (nCATS), Bioengineering Science Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ, UK
- Biomechanics and Mechanobiology Laboratory, Biomedical Engineering Division, Department of Human Biology, Faculty of Health Sciences, University of Cape Town, Anzio Road, Observatory 7925, Cape Town, South Africa
| |
Collapse
|
13
|
Jor JWY, Parker MD, Taberner AJ, Nash MP, Nielsen PMF. Computational and experimental characterization of skin mechanics: identifying current challenges and future directions. WILEY INTERDISCIPLINARY REVIEWS-SYSTEMS BIOLOGY AND MEDICINE 2013; 5:539-56. [PMID: 23757148 DOI: 10.1002/wsbm.1228] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2013] [Revised: 04/25/2013] [Accepted: 04/26/2013] [Indexed: 12/21/2022]
Abstract
The characterization of skin mechanics has many clinical implications and has been an active area of research for the past few decades. Biomechanical models have evolved from earlier empirical models to state-of-the-art structural models that provide linkage between tissue microstructure and macroscopic stress-strain response. To maximize the accuracy and predictive capabilities of such computational models, there is a need to reliably identify often a large number of unknown model parameters. This is critically dependent on the availability of experimental data that cover an extensive range of different deformation modes, and quantification of internal structural features, such as collagen orientation. To this end, future challenges should include the ongoing development of noninvasive instrumentation and imaging modalities for in vivo skin measurements. We highlight the important concept of tightly integrating computational models, instrumentation, and imaging modalities into a single platform to investigate skin biomechanics.
Collapse
Affiliation(s)
- Jessica W Y Jor
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | | | | | | | | |
Collapse
|
14
|
Chadefaux D, Le Carrou JL, Fabre B. A model of harp plucking. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2013; 133:2444-2455. [PMID: 23556609 DOI: 10.1121/1.4792249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
In this paper, a model of the harp plucking is developed. It is split into two successive time phases, the sticking and the slipping phases, and uses a mechanical description of the human finger's behavior. The parameters of the model are identified through measurements of the finger/string displacements during the interaction. The validity of the model is verified using a configurable and repeatable robotic finger, enhanced with a silicone layer. A parametric study is performed to investigate the influence of the model's parameters on the free oscillations of the string. As a result, a direct implementation of the model produces an accurate simulation of a string response to a given finger motion, as compared to experimental data. The set of parameters that govern the plucking action is divided into two groups: Parameters controlled by the harpist and parameters intrinsic to the plucking. The former group and to a lesser extent the latter highly influence the initial conditions of the string vibrations. The simulations of the string's free oscillations highlight the large impact the model parameters have on the sound produced and therefore allows the understanding of how different players on the same instrument can produce a specific/personal sound quality.
Collapse
|
15
|
Yildiz MZ, Güçlü B. Relationship between vibrotactile detection threshold in the Pacinian channel and complex mechanical modulus of the human glabrous skin. Somatosens Mot Res 2013; 30:37-47. [DOI: 10.3109/08990220.2012.754754] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
16
|
Qiang B, Greenleaf J, Oyen M, Zhang X. Estimating material elasticity by spherical indentation load-relaxation tests on viscoelastic samples of finite thickness. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2011; 58:1418-29. [PMID: 21768026 DOI: 10.1109/tuffc.2011.1961] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
A two-step viscoelastic spherical indentation method is proposed to compensate for 1) material relaxation and 2) sample thickness. In the first step, the indenter is moved at a constant speed and the reaction force is measured. In the second step, the indenter is held at a constant position and the relaxation response of the material is measured. Then the relaxation response is fit with a multi-exponential function which corresponds to a three-branch general Maxwell model. The relaxation modulus is derived by correcting the finite ramp time introduced in the first step. The proposed model takes into account the sample thickness, which is important for applications in which the sample thickness is less than ten times the indenter radius. The model is validated numerically by finite element simulations. Experiments are carried out on a 10% gelatin phantom and a chicken breast sample with the proposed method. The results for both the gelatin phantom and the chicken breast sample agree with the results obtained from a surface wave method. Both the finite element simulations and experimental results show improved elasticity estimations by incorporating the sample thickness into the model. The measured shear elasticities of the 10% gelatin sample are 6.79 and 6.93 kPa by the proposed finite indentation method at sample thickness of 40 and 20 mm, respectively. The elasticity of the same sample is estimated to be 6.53 kPa by the surface wave method. For the chicken breast sample, the shear elasticity is measured to be 4.51 and 5.17 kPa by the proposed indentation method at sample thickness of 40 and 20 mm, respectively. Its elasticity is measured by the surface wave method to be 4.14 kPa.
Collapse
Affiliation(s)
- Bo Qiang
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, MN, USA.
| | | | | | | |
Collapse
|
17
|
Use of the dynamic volume spline method to predict facial soft tissue changes associated with orthognathic surgery. ACTA ACUST UNITED AC 2010; 110:e17-23. [DOI: 10.1016/j.tripleo.2010.06.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2009] [Revised: 06/05/2010] [Accepted: 06/14/2010] [Indexed: 11/16/2022]
|
18
|
Schiffter H, Condliffe J, Vonhoff S. Spray-freeze-drying of nanosuspensions: the manufacture of insulin particles for needle-free ballistic powder delivery. J R Soc Interface 2010; 7 Suppl 4:S483-500. [PMID: 20519207 DOI: 10.1098/rsif.2010.0114.focus] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
The feasibility of preparing microparticles with high insulin loading suitable for needle-free ballistic drug delivery by spray-freeze-drying (SFD) was examined in this study. The aim was to manufacture dense, robust particles with a diameter of around 50 microm, a narrow size distribution and a high content of insulin. Atomization using ultrasound atomizers showed improved handling of small liquid quantities as well as narrower droplet size distributions over conventional two-fluid nozzle atomization. Insulin nanoparticles were produced by SFD from solutions with a low solid content (<10 mg ml(-1)) and subsequent ultra-turrax homogenization. To prepare particles for needle-free ballistic injection, the insulin nanoparticles were suspended in matrix formulations with a high excipient content (>300 mg ml(-1)) consisting of trehalose, mannitol, dextran (10 kDa) and dextran (150 kDa) (abbreviated to TMDD) in order to maximize particle robustness and density after SFD. With the increase in insulin content, the viscosity of the nanosuspensions increased. Liquid atomization was possible up to a maximum of 250 mg of nano-insulin suspended in a 1.0 g matrix. However, if a narrow size distribution with a good correlation between theoretical and measurable insulin content was desired, no more than 150 mg nano-insulin could be suspended per gram of matrix formulation. Particles were examined by laser light diffraction, scanning electron microscopy and tap density testing. Insulin stability was assessed using size exclusion chromatography (SEC), reverse phase chromatography and Fourier transform infrared (FTIR) spectroscopy. Densification of the particles could be achieved during primary drying if the product temperature (T(prod)) exceeded the glass transition temperature of the freeze concentrate (T(g)') of -29.4 degrees C for TMDD (3331) formulations. Particles showed a collapsed and wrinkled morphology owing to viscous flow of the freeze concentrate. With increasing insulin loading, the d (v, 0.5) of the SFD powders increased and particle size distributions got wider. Insulin showed a good stability during the particle formation process with a maximum decrease in insulin monomer of only 0.123 per cent after SFD. In accordance with the SEC data, FTIR analysis showed only a small increase in the intermolecular beta-sheet of 0.4 per cent after SFD. The good physical stability of the polydisperse particles made them suitable for ballistic injection into tissue-mimicking agar hydrogels, showing a mean penetration depth of 251.3 +/- 114.7 microm.
Collapse
Affiliation(s)
- Heiko Schiffter
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Old Road Campus Research Building, Off Roosevelt Drive, Oxford OX3 7DQ, UK.
| | | | | |
Collapse
|