1
|
Maffiuletti NA, Dirks ML, Stevens-Lapsley J, McNeil CJ. Electrical stimulation for investigating and improving neuromuscular function in vivo: Historical perspective and major advances. J Biomech 2023; 152:111582. [PMID: 37088030 DOI: 10.1016/j.jbiomech.2023.111582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 04/04/2023] [Indexed: 04/25/2023]
Abstract
This historical review summarizes the major advances - particularly from the last 50 years - in transcutaneous motor-level electrical stimulation, which can be used either as a tool to investigate neuromuscular function and its determinants (electrical stimulation for testing; EST) or as a therapeutic/training modality to improve neuromuscular and physical function (neuromuscular electrical stimulation; NMES). We focus on some of the most important applications of electrical stimulation in research and clinical settings, such as the investigation of acute changes, chronic adaptations and pathological alterations of neuromuscular function with EST, as well as the enhancement, preservation and restoration of muscle strength and mass with NMES treatment programs in various populations. For both EST and NMES, several major advances converge around understanding and optimizing motor unit recruitment during electrically-evoked contractions, also taking into account the influence of stimulation site (e.g., muscle belly vs nerve trunk) and type (e.g., pulse duration, frequency, and intensity). This information is equally important both in the context of mechanistic research of neuromuscular function as well as for clinicians who believe that improvements in neuromuscular function are required to provide health-related benefits to their patients.
Collapse
Affiliation(s)
| | - Marlou L Dirks
- Department of Public Health and Sports Sciences, Faculty of Health and Life Sciences, University of Exeter, Exeter, UK; Human and Animal Physiology, Wageningen University, Wageningen, The Netherlands
| | - Jennifer Stevens-Lapsley
- Physical Therapy Program, Department of Physical Medicine and Rehabilitation, University of Colorado, Aurora, CO, USA; VA Eastern Colorado Geriatric Research, Education, and Clinical Center (GRECC), VA Eastern Colorado Health Care System, Aurora, CO, USA
| | - Chris J McNeil
- Integrated Neuromuscular Physiology Laboratory, School of Health and Exercise Sciences, University of British Columbia, Kelowna, Canada
| |
Collapse
|
2
|
Popović‐Maneski L, Mateo S. MotiMove: Multi‐purpose transcutaneous functional electrical stimulator. Artif Organs 2022. [DOI: 10.1111/aor.14379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
| | - Sébastien Mateo
- Trajectoires Team, Lyon Neuroscience Research Center, CNRS UMR5292, INSERM U1028 Université Lyon 1, Université de Lyon Lyon France
- Plate‐forme Mouvement et Handicap Hospices Civils de Lyon, Hôpital Henry Gabrielle Lyon France
| |
Collapse
|
3
|
Gelenitis K, Foglyano K, Lombardo L, McDaniel J, Triolo R. Motorless cadence control of standard and low duty cycle-patterned neural stimulation intensity extends muscle-driven cycling output after paralysis. J Neuroeng Rehabil 2022; 19:85. [PMID: 35945575 PMCID: PMC9360711 DOI: 10.1186/s12984-022-01064-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Accepted: 07/21/2022] [Indexed: 12/01/2022] Open
Abstract
Background Stimulation-driven exercise is often limited by rapid fatigue of the activated muscles. Selective neural stimulation patterns that decrease activated fiber overlap and/or duty cycle improve cycling exercise duration and intensity. However, unequal outputs from independently activated fiber populations may cause large discrepancies in power production and crank angle velocity among pedal revolutions. Enforcing a constant cadence through feedback control of stimulus levels may address this issue and further improve endurance by targeting a submaximal but higher than steady-state exercise intensity. Methods Seven participants with paralysis cycled using standard cadence-controlled stimulation (S-Cont). Four of those participants also cycled with a low duty cycle (carousel) cadence-controlled stimulation scheme (C-Cont). S-Cont and C-Cont patterns were compared with conventional maximal stimulation (S-Max). Outcome measures include total work (W), end power (Pend), power fluctuation (PFI), charge accumulation (Q) and efficiency (η). Physiological measurements of muscle oxygenation (SmO2) and heart rate were also collected with select participants. Results At least one cadence-controlled stimulation pattern (S-Cont or C-Cont) improved Pend over S-Max in all participants and increased W in three participants. Both controlled patterns increased Q and η and reduced PFI compared with S-Max and prior open-loop studies. S-Cont stimulation also delayed declines in SmO2 and increased heart rate in one participant compared with S-Max. Conclusions Cadence-controlled selective stimulation improves cycling endurance and increases efficiency over conventional stimulation by incorporating fiber groups only as needed to maintain a desired exercise intensity. Closed-loop carousel stimulation also successfully reduces power fluctuations relative to previous open-loop efforts, which will enable neuroprosthesis recipients to better take advantage of duty cycle reducing patterns.
Collapse
Affiliation(s)
- Kristen Gelenitis
- Louis Stokes Cleveland VA Medical Center, 10701 East Blvd, Cleveland, OH, 44106, USA.
| | - Kevin Foglyano
- Louis Stokes Cleveland VA Medical Center, 10701 East Blvd, Cleveland, OH, 44106, USA
| | - Lisa Lombardo
- Louis Stokes Cleveland VA Medical Center, 10701 East Blvd, Cleveland, OH, 44106, USA
| | - John McDaniel
- Louis Stokes Cleveland VA Medical Center, 10701 East Blvd, Cleveland, OH, 44106, USA.,Kent State University, 800 E Summit St, Kent, OH, 44240, USA
| | - Ronald Triolo
- Louis Stokes Cleveland VA Medical Center, 10701 East Blvd, Cleveland, OH, 44106, USA.,Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH, 44106, USA
| |
Collapse
|
4
|
Hirai T, Jiang Y, Sugi M, Togo S, Yokoi H. Investigation of Motor Point Shift and Contraction Force of Triceps Brachii for Functional Electrical Stimulation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:6330-6333. [PMID: 34892561 DOI: 10.1109/embc46164.2021.9630372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Functional electrical stimulation (FES) has been used for neurorehabilitation of individuals with paralysis due to spinal cord injuries or stroke aftereffects. The biceps brachii is often adopted in studies on FES because of the ease of stimulation, while there are few studies on the triceps brachii. Stimulation of the triceps brachii is important because the biceps brachii tends to be spastic. The aim of this study is to investigate the position shift of the motor points (MPs) of the three main muscle groups in triceps brachii with respect to the elbow joint angle, and the contraction force of the muscle groups. Firstly, MPs were measured in 6 healthy individuals using an MP pen at 5 elbow joint angles. The MPs of the long and lateral heads shifted distally and laterally, and the MPs of the medial head shifted distally and medially as the arm extended. The MPs of the long head shifted farthest of all. Secondly, the contraction force was measured in 9 healthy individuals using a force gauge at elbow joint angle of 90 degrees. Three different voltages were applied: 4, 8, and 12 V. The results showed that the medial head yields a sufficient contraction force although the medial head is situated deeper than the other two muscle groups. These findings will help to better understand the stimulation of the triceps brachii and improve the efficiency of electrical stimulation therapy.
Collapse
|
5
|
Ceroni I, Ferrante S, Conti F, No SJ, Gasperina SD, Dell'Eva F, Pedrocchi A, Tarabini M, Ambrosini E. Comparing Fatigue Reducing Stimulation Strategies During Cycling Induced by Functional Electrical Stimulation: a Case Study with one Spinal Cord Injured Subject. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:6394-6397. [PMID: 34892575 DOI: 10.1109/embc46164.2021.9630197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
This case study was designed starting from our experience at CYBATHLON 2020. The specific aim of this work was to compare the effectiveness of different fatigue reducing stimulation strategies during cycling induced by Functional Electrical Stimulation (FES). The compared stimulation strategies were: traditional constant frequency trains (CFTs) at 30 and 40Hz, doublet frequency trains (DFTs) and spatially distributed sequential stimulation (SDSS) on the quadriceps muscles. One Spinal Cord Injured (SCI) subject (39 years, T5-T6, male, ASIA A) was involved in 12 experimental sessions during which the four strategies were tested in a randomized order during FES-induced cycling performed on a passive trike at a constant cadence of 35 RPM. FES was delivered to four muscle groups (quadriceps, gluteal muscles, hamstrings and gastrocnemius) for each leg. The performance was evaluated in terms of saturation time (i.e., the time elapsed from the beginning of the stimulation until the predetermined maximum value of current amplitude is reached) and root mean square error (RMSE) of the actual cadence with respect to the target value. SDSS achieved a statistical lower saturation time and a qualitative higher RMSE of the cadence with respect to CFTs both at 30 and 40Hz.Clinical relevance- Conversely to previous literature, SDSS seems to be ineffective to reduce muscle fatigue during FES-induced cycling. Further experiments are needed to confirm this result.
Collapse
|
6
|
Ye G, Ali SS, Bergquist AJ, Popovic MR, Masani K. A Generic Sequential Stimulation Adapter for Reducing Muscle Fatigue during Functional Electrical Stimulation. SENSORS 2021; 21:s21217248. [PMID: 34770555 PMCID: PMC8587998 DOI: 10.3390/s21217248] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Revised: 10/25/2021] [Accepted: 10/26/2021] [Indexed: 11/24/2022]
Abstract
Background: Clinical applications of conventional functional electrical stimulation (FES) administered via a single electrode are limited by rapid onset neuromuscular fatigue. “Sequential” (SEQ) stimulation, involving the rotation of pulses between multiple active electrodes, has been shown to reduce fatigue compared to conventional FES. However, there has been limited adoption of SEQ in research and clinical settings. Methods: The SEQ adapter is a small, battery-powered device that transforms the output of any commercially available electrical stimulator into SEQ stimulation. We examined the output of the adaptor across a range of clinically relevant stimulation pulse parameters to verify the signal integrity preservation ability of the SEQ adapter. Pulse frequency, amplitude, and duration were varied across discrete states between 4 and 200 Hz, 10 and100 mA, and 50 and 2000 μs, respectively. Results: A total of 420 trials were conducted, with 80 stimulation pulses per trial. The SEQ adapter demonstrated excellent preservation of signal integrity, matching the pulse characteristics of the originating stimulator within 1% error. The SEQ adapter operates as expected at pulse frequencies up to 160 Hz, failing at a frequency of 200 Hz. Conclusion: The SEQ adapter represents an effective and low-cost solution to increase the utilization of SEQ in existing rehabilitation paradigms.
Collapse
Affiliation(s)
- Gongkai Ye
- KITE-Toronto Rehabilitation Institute, University Health Network, Toronto, ON M4G 3V9, Canada; (G.Y.); (A.J.B.); (M.R.P.)
| | - Saima S. Ali
- Department of Electrical and Computer Engineering, University of Toronto, Toronto, ON M5S 3G4, Canada;
| | - Austin J. Bergquist
- KITE-Toronto Rehabilitation Institute, University Health Network, Toronto, ON M4G 3V9, Canada; (G.Y.); (A.J.B.); (M.R.P.)
| | - Milos R. Popovic
- KITE-Toronto Rehabilitation Institute, University Health Network, Toronto, ON M4G 3V9, Canada; (G.Y.); (A.J.B.); (M.R.P.)
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada
| | - Kei Masani
- KITE-Toronto Rehabilitation Institute, University Health Network, Toronto, ON M4G 3V9, Canada; (G.Y.); (A.J.B.); (M.R.P.)
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada
- Correspondence:
| |
Collapse
|
7
|
Barss TS, Sallis BWM, Miller DJ, Collins DF. Does increasing the number of channels during neuromuscular electrical stimulation reduce fatigability and produce larger contractions with less discomfort? Eur J Appl Physiol 2021; 121:2621-2633. [PMID: 34131798 DOI: 10.1007/s00421-021-04742-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 06/08/2021] [Indexed: 11/27/2022]
Abstract
PURPOSE Neuromuscular electrical stimulation (NMES) is often delivered at frequencies that recruit motor units (MUs) at unphysiologically high rates, leading to contraction fatigability. Rotating NMES pulses between multiple electrodes recruits subpopulations of MUs from each site, reducing MU firing rates and fatigability. This study was designed to determine whether rotating pulses between an increasing number of stimulation channels (cathodes) reduces contraction fatigability and increases the ability to generate torque during NMES. A secondary outcome was perceived discomfort. METHODS Fifteen neurologically intact volunteers completed four sessions. NMES was delivered over the quadriceps through 1 (NMES1), 2 (NMES2), 4 (NMES4) or 8 (NMES8) channels. Fatigability was assessed over 100 contractions (1-s on/1-s off) at an initial contraction amplitude that was 20% of a maximal voluntary contraction. Torque-frequency relationships were characterized over six frequencies from 20 to 120 Hz. RESULTS NMES4 and NMES8 resulted in less decline in peak torque (42 and 41%) over the 100 contractions than NMES1 and NMES2 (53 and 50% decline). Increasing frequency from 20 to 120 Hz increased torque by 7, 13, 21 and 24% MVC, for NMES1, NMES2, NMES4 and NMES8, respectively. Perceived discomfort was highest during NMES8. CONCLUSION NMES4 and NMES8 reduced contraction fatigability and generated larger contractions across a range of frequencies than NMES1 and NMES2. NMES8 produced the most discomfort, likely due to small electrodes and high current density. During NMES, more is not better and rotating pulses between four channels may be optimal to reduce contraction fatigability and produce larger contractions with minimal discomfort compared to conventional NMES configurations.
Collapse
Affiliation(s)
- Trevor S Barss
- Human Neurophysiology Laboratory, Faculty of Kinesiology, Sport, and Recreation, University of Alberta, 4-219 Van Vliet Complex, Edmonton, AB, T6G 2H9, Canada.,Neuroscience and Mental Health Institute, University of Alberta, Edmonton, AB, Canada
| | - Bailey W M Sallis
- Human Neurophysiology Laboratory, Faculty of Kinesiology, Sport, and Recreation, University of Alberta, 4-219 Van Vliet Complex, Edmonton, AB, T6G 2H9, Canada.,Neuroscience and Mental Health Institute, University of Alberta, Edmonton, AB, Canada
| | - Dylan J Miller
- Human Neurophysiology Laboratory, Faculty of Kinesiology, Sport, and Recreation, University of Alberta, 4-219 Van Vliet Complex, Edmonton, AB, T6G 2H9, Canada.,Neuroscience and Mental Health Institute, University of Alberta, Edmonton, AB, Canada
| | - David F Collins
- Human Neurophysiology Laboratory, Faculty of Kinesiology, Sport, and Recreation, University of Alberta, 4-219 Van Vliet Complex, Edmonton, AB, T6G 2H9, Canada. .,Neuroscience and Mental Health Institute, University of Alberta, Edmonton, AB, Canada.
| |
Collapse
|
8
|
Abstract
For individuals with movement impairments due to neurological injuries, rehabilitative therapies such as functional electrical stimulation (FES) and rehabilitation robots hold vast potential to improve their mobility and activities of daily living. Combining FES with rehabilitation robots results in intimately coordinated human–robot interaction. An example of such interaction is FES cycling, where motorized assistance can provide high-intensity and repetitive practice of coordinated limb motion, resulting in physiological and functional benefits. In this paper, the development of multiple FES cycling testbeds and safeguards is described, along with the switched nonlinear dynamics of the cycle–rider system. Closed-loop FES cycling control designs are described for cadence and torque tracking. For each tracking objective, the authors’ past work on robust and adaptive controllers used to compute muscle stimulation and motor current inputs is presented and discussed. Experimental results involving both able-bodied individuals and participants with neurological injuries are provided for each combination of controller and tracking objective. Trade-offs for the control algorithms are discussed based on the requirements for implementation, desired rehabilitation outcomes and resulting rider performance. Lastly, future works and the applicability of the developed methods to additional technologies including teleoperated robotics are outlined.
Collapse
|
9
|
Schmoll M, Le Guillou R, Lobato Borges D, Fattal C, Fachin-Martins E, Azevedo Coste C. Standardizing fatigue-resistance testing during electrical stimulation of paralysed human quadriceps muscles, a practical approach. J Neuroeng Rehabil 2021; 18:11. [PMID: 33478556 PMCID: PMC7818559 DOI: 10.1186/s12984-021-00805-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Accepted: 01/11/2021] [Indexed: 11/10/2022] Open
Abstract
Background Rapid onset of muscular fatigue is still one of the main issues of functional electrical stimulation (FES). A promising technique, known as distributed stimulation, aims to activate sub-units of a muscle at a lower stimulation frequency to increase fatigue-resistance. Besides a general agreement on the beneficial effects, the great heterogeneity of evaluation techniques, raises the demand for a standardized method to better reflect the requirements of a practical application. Methods This study investigated the fatigue-development of 6 paralysed quadriceps muscles over the course of 180 dynamic contractions, evaluating different electrode-configurations (conventional and distributed stimulation). For a standardized comparison, fatigue-testing was performed at 40% of the peak-torque during a maximal evoked contraction (MEC). Further, we assessed the isometric torque for each electrode-configuration at different knee-extension-angles (70°–170°, 10° steps). Results Our results showed no significant difference in the fatigue-index for any of the tested electrode-configurations, compared to conventional-stimulation. We conjecture that the positive effects of distributed stimulation become less pronounced at higher stimulation amplitudes. The isometric torque produced at different knee-extension angles was similar for most electrode-configurations. Maximal torque-production was found at 130°–140° knee-extension-angle, which correlates with the maximal knee-flexion-angles during running. Conclusion In most practical applications, FES is intended to initiate dynamic movements. Therefore, it is crucial to assess fatigue-resistance by using dynamic contractions. Reporting the relationship between produced torque and knee-extension-angle can help to observe the stability of a chosen electrode-configuration for a targeted range-of-motion. Additionally, we suggest to perform fatigue testing at higher forces (e.g. 40% of the maximal evoked torque) in pre-trained subjects with SCI to better reflect the practical demands of FES-applications.
Collapse
Affiliation(s)
- Martin Schmoll
- INRIA - LIRMM, Université de Montpellier, Montpellier, France.
| | | | | | | | | | | |
Collapse
|
10
|
Buckmire AJ, Lockwood DR, Doane CJ, Fuglevand AJ. Distributed stimulation increases force elicited with functional electrical stimulation. J Neural Eng 2019; 15:026001. [PMID: 29099387 DOI: 10.1088/1741-2552/aa9820] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
OBJECTIVE The maximum muscle forces that can be evoked using functional electrical stimulation (FES) are relatively modest. The reason for this weakness is not fully understood but could be partly related to the widespread distribution of motor nerve branches within muscle. As such, a single stimulating electrode (as is conventionally used) may be incapable of activating the entire array of motor axons supplying a muscle. Therefore, the objective of this study was to determine whether stimulating a muscle with more than one source of current could boost force above that achievable with a single source. APPROACH We compared the maximum isometric forces that could be evoked in the anterior deltoid of anesthetized monkeys using one or two intramuscular electrodes. We also evaluated whether temporally interleaved stimulation between two electrodes might reduce fatigue during prolonged activity compared to synchronized stimulation through two electrodes. MAIN RESULTS We found that dual electrode stimulation consistently produced greater force (~50% greater on average) than maximal stimulation with single electrodes. No differences, however, were found in the fatigue responses using interleaved versus synchronized stimulation. SIGNIFICANCE It seems reasonable to consider using multi-electrode stimulation to augment the force-generating capacity of muscles and thereby increase the utility of FES systems.
Collapse
Affiliation(s)
- Alie J Buckmire
- Department of Physiology, University of Arizona, Tucson, AZ, United States of America.,Department of Neuroscience, University of Arizona, Tucson, AZ, United States of America
| | - Danielle R Lockwood
- Department of Physiology, University of Arizona, Tucson, AZ, United States of America
| | - Cynthia J Doane
- University Animal Care, University of Arizona, Tucson, AZ, United States of America
| | - Andrew J Fuglevand
- Department of Physiology, University of Arizona, Tucson, AZ, United States of America.,Department of Neuroscience, University of Arizona, Tucson, AZ, United States of America
| |
Collapse
|
11
|
Laubacher M, Aksoez EA, Brust AK, Baumberger M, Riener R, Binder-Macleod S, Hunt KJ. Stimulation of paralysed quadriceps muscles with sequentially and spatially distributed electrodes during dynamic knee extension. J Neuroeng Rehabil 2019; 16:5. [PMID: 30616683 PMCID: PMC6322281 DOI: 10.1186/s12984-018-0471-y] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2018] [Accepted: 12/05/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND During functional electrical stimulation (FES) tasks with able-bodied (AB) participants, spatially distributed sequential stimulation (SDSS) has demonstrated substantial improvements in power output and fatigue properties compared to conventional single electrode stimulation (SES). The aim of this study was to compare the properties of SDSS and SES in participants with spinal cord injury (SCI) in a dynamic isokinetic knee extension task simulating knee movement during recumbent cycling. METHOD Using a case-series design, m. vastus lateralis and medialis of four participants with motor and sensory complete SCI (AIS A) were stimulated for 6 min on both legs with both electrode setups. With SES, target muscles were stimulated by a pair of electrodes. In SDSS, the distal electrodes were replaced by four small electrodes giving the same overall stimulation frequency and having the same total surface area. Torque was measured during knee extension by a dynamometer at an angular velocity of 110 deg/s. Mean power of the left and right sides (PmeanL,R) was calculated from all stimulated extensions for initial, final and all extensions. Fatigue is presented as an index value with respect to initial power from 1 to 0, whereby 1 means no fatigue. RESULTS SDSS showed higher PmeanL,R values for all four participants for all extensions (increases of 132% in participant P1, 100% in P2, 36% in P3 and 18% in P4 compared to SES) and for the initial phase (increases of 84%, 59%, 66%, and 16%, respectively). Fatigue resistance was better with SDSS for P1, P2 and P4 but worse for P3 (0.47 vs 0.35, 0.63 vs 0.49, 0.90 vs 0.82 and 0.59 vs 0.77, respectively). CONCLUSION Consistently higher PmeanL,R was observed for all four participants for initial and overall contractions using SDSS. This supports findings from previous studies with AB participants. Fatigue properties were better in three of the four participants. The lower fatigue resistance with SDSS in one participant may be explained by a very low muscle activation level in this case. Further investigation in a larger cohort is warranted.
Collapse
Affiliation(s)
- Marco Laubacher
- Department of Physical Therapy, University of Delaware, Newark, United States of America.
| | - Efe A Aksoez
- Department of Physical Therapy, University of Delaware, Newark, United States of America
| | - Anne K Brust
- Department of Physical Therapy, University of Delaware, Newark, United States of America
| | - Michael Baumberger
- Institute for Rehabilitation and Performance Technology, Division of Mechanical Engineering, Department of Engineering and Information Technology, Bern University of Applied Sciences, Pestalozzistrasse 20, Burgdorf, 3400, Switzerland.,Sensory Motor Systems Lab, Department of Health Sciences and Technology, ETH Zurich, Zurich, 8000, Switzerland
| | - Robert Riener
- Institute for Rehabilitation and Performance Technology, Division of Mechanical Engineering, Department of Engineering and Information Technology, Bern University of Applied Sciences, Pestalozzistrasse 20, Burgdorf, 3400, Switzerland.,Sensory Motor Systems Lab, Department of Health Sciences and Technology, ETH Zurich, Zurich, 8000, Switzerland
| | | | | |
Collapse
|
12
|
Boudville R, Hussain Z, Yahaya SZ, Abd Rahman MF, Ahmad KA, Husin NI. Development and Optimization of PID Control for FES Knee Exercise in Hemiplegic Rehabilitation. 2018 12TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST) 2018. [DOI: 10.1109/icsenst.2018.8603628] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
13
|
Buckmire AJ, Arakeri TJ, Reinhard JP, Fuglevand AJ. Mitigation of excessive fatigue associated with functional electrical stimulation. J Neural Eng 2018; 15:066004. [PMID: 30168443 DOI: 10.1088/1741-2552/aade1c] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
OBJECTIVE Restoration of motor function in paralyzed limbs using functional electrical stimulation (FES) is undermined by rapid fatigue associated with artificial stimulation. Typically, single electrodes are used to activate muscles with FES. However, due to the highly distributed branching of muscle nerves, a single electrode may not be able to activate the entire array of motor axons supplying a muscle. Therefore, stimulating muscle with multiple electrodes might enable access to a larger volume of muscle and thereby reduce fatigue. APPROACH Accordingly, we compared the endurance times that ankle dorsiflexion could be sustained at 20% maximum voluntary force using feedback controlled stimulation (25 Hz) of human tibialis anterior (TA) using one or four percutaneous intramuscular electrodes. In addition, we measured endurance times in response to direct stimulation of the nerve supplying TA and during voluntary contraction. In all sessions involving electrical stimulation, an anesthetic nerve block proximal to the site of stimulation was used to isolate the effects of stimulation and alleviate discomfort. MAIN RESULTS Endurance time associated with stimuli delivered by a single intramuscular electrode (84 ± 19 s) was significantly smaller than that elicited by four intramuscular electrodes (232 ± 123 s). Moreover, endurance time in response to nerve stimulation (787 ± 201 s) was not significantly different that that produced during voluntary contraction (896 ± 272 s). SIGNIFICANCE Therefore, excessive fatigue associated with FES is probably due to the inability of conventional FES systems to enlist the full complement of motor axons innervating muscle and can be mitigated using multiple electrodes or nerve-based electrodes.
Collapse
Affiliation(s)
- Alie J Buckmire
- Department of Physiology, College of Medicine, University of Arizona, Tucson, AZ, United States of America. Graduate Program in Neuroscience, College of Medicine, University of Arizona, Tucson, AZ, United States of America
| | | | | | | |
Collapse
|
14
|
Rongsawad K, Ratanapinunchai J. Effects of Very High Stimulation Frequency and Wide-Pulse Duration on Stimulated Force and Fatigue of Quadriceps in Healthy Participants. Ann Rehabil Med 2018; 42:250-259. [PMID: 29765878 PMCID: PMC5940601 DOI: 10.5535/arm.2018.42.2.250] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2017] [Accepted: 08/02/2017] [Indexed: 11/13/2022] Open
Abstract
Objective To determine the effect of very high stimulation frequency (150 and 200 Hz) with wide pulse duration versus 50 Hz with wide pulse duration on stimulated force and fatigue of quadriceps femoris in healthy participants. Methods Thirty-four healthy participants underwent fatigue test using three stimulation frequency conditions (50, 150, and 200 Hz) with pulse duration of 0.9 ms. Normalized force values at the end of each fatigue protocol and curve fitting patterns were compared among stimulated frequencies. Results Very high stimulation frequency (150 and 200 Hz) conditions showed a trend of having more decline in normalized stimulated force during fatigue test compared to a low stimulation frequency at 50 Hz. However, the difference was not statistically significant. Responder group showed the same slope of a linear fitting pattern, implying the same pattern of muscle fatigue among three stimulation frequency conditions (−3.32 in 50 Hz, −2.88 in 150 Hz, and −3.14 in 200 Hz, respectively). Conclusion There were high inter-subject variations in the response to different frequency stimulation conditions. However, very high stimulation frequency generated the same fatigue pattern as the low stimulation frequency in the responder group. Further research is needed to explore the mechanism involved.
Collapse
Affiliation(s)
- Kitima Rongsawad
- Department of Physical Therapy, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand
| | - Jonjin Ratanapinunchai
- Department of Physical Therapy, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand
| |
Collapse
|
15
|
Electrode placement on the forearm for selective stimulation of finger extension/flexion. PLoS One 2018; 13:e0190936. [PMID: 29324829 PMCID: PMC5764314 DOI: 10.1371/journal.pone.0190936] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2017] [Accepted: 12/22/2017] [Indexed: 12/17/2022] Open
Abstract
It is still challenging to achieve a complex grasp or fine finger control by using surface functional electrical stimulation (FES), which usually requires a precise electrode configuration under laboratory or clinical settings. The goals of this study are as follows: 1) to study the possibility of selectively activating individual fingers; 2) to investigate whether the current activation threshold and selective range of individual fingers are affected by two factors: changes in the electrode position and forearm rotation (pronation, neutral and supination); and 3) to explore a theoretical model for guidance of the electrode placement used for selective activation of individual fingers. A coordinate system with more than 400 grid points was established over the forearm skin surface. A searching procedure was used to traverse all grid points to identify the stimulation points for finger extension/flexion by applying monophasic stimulation pulses. Some of the stimulation points for finger extension and flexion were selected and tested in their respective two different forearm postures according to the number and the type of the activated fingers and the strength of finger action response to the electrical stimulation at the stimulation point. The activation thresholds and current ranges of the selectively activated finger at each stimulation point were determined by visual analysis. The stimulation points were divided into three groups (“Low”, “Medium” and “High”) according to the thresholds of the 1st activated fingers. The angles produced by the selectively activated finger within selective current ranges were measured and analyzed. Selective stimulation of extension/flexion is possible for most fingers. Small changes in electrode position and forearm rotation have no significant effect on the threshold amplitude and the current range for the selective activation of most fingers (p > 0.05). The current range is the largest (more than 2 mA) for selective activation of the thumb, followed by those for the index, ring, middle and little fingers. The stimulation points in the “Low” group for all five fingers lead to noticeable finger angles at low current intensity, especially for the index, middle, and ring fingers. The slopes of the finger angle variation in the “Low” group for digits 2~4 are inversely proportional to the current intensity, whereas the slopes of the finger angle variation in other groups and in all groups for the thumb and little finger are proportional to the current intensity. It is possible to selectively activate the extension/flexion of most fingers by stimulating the forearm muscles. The physiological characteristics of each finger should be considered when placing the negative electrode for selective stimulation of individual fingers. The electrode placement used for the selective activation of individual fingers should not be confined to the location with the lowest activation threshold.
Collapse
|
16
|
Metani A, Popović-Maneski L, Mateo S, Lemahieu L, Bergeron V. Functional electrical stimulation cycling strategies tested during preparation for the First Cybathlon Competition - a practical report from team ENS de Lyon. Eur J Transl Myol 2017; 27:7110. [PMID: 29299222 PMCID: PMC5745378 DOI: 10.4081/ejtm.2017.7110] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2017] [Revised: 11/21/2017] [Accepted: 11/27/2017] [Indexed: 02/08/2023] Open
Abstract
Whether it is from the patient’s or the physical therapist’s point of view, FES cycling can be considered either as a recreational activity, or an engaging rehabilitation tool. In both cases, it keeps patients with lower-limb paralysis motivated to sustain a regular physical activity. Thus, it is not surprising that it was selected as one of the six disciplines of the first Cybathlon competition held on October 8, 2016. However, many unresolved issues prevent FES cycling from being an activity practiced outdoors on a daily basis; such as, low power production, rapid muscle fatigue, precise electrode positioning, lack of systematic procedures to determine stimulation patterns, and the difficulty of transferring disabled riders from their wheelchair to the tricycle. This article documents the challenges we faced during preparation for the Cybathlon 2016 FES cycling race, and provides results obtained during different phases of the process. A particular specificity of our team was that, unlike most other teams where pilots were mainly paraplegic, both the primary and backup pilots for team ENS de Lyon are C6/C7 tetraplegics, with neither voluntary control of their abdominal muscles nor hand grip, and only partial use of their arms.
Collapse
Affiliation(s)
- Amine Metani
- École Normale Supérieure de Lyon, CNRS UMR 5672, Lyon, France
| | - Lana Popović-Maneski
- Institute of Technical Sciences of the Serbian Academy of Sciences and Arts, Belgrade, Serbia
| | - Sebastien Mateo
- Université de Lyon, Université de Lyon 1, INSERM U1028, CNRS UMR 5292, Lyon Neuroscience Research Center, ImpAct Team, Lyon, France.,Hospices Civils de Lyon, Hôpital Henry Gabrielle, Plateforme Mouvement et Handicap, Lyon, France
| | - Laura Lemahieu
- École Normale Supérieure de Lyon, CNRS UMR 5672, Lyon, France
| | - Vance Bergeron
- École Normale Supérieure de Lyon, CNRS UMR 5672, Lyon, France
| |
Collapse
|
17
|
Laubacher M, Aksöz AE, Riener R, Binder-Macleod S, Hunt KJ. Power output and fatigue properties using spatially distributed sequential stimulation in a dynamic knee extension task. Eur J Appl Physiol 2017; 117:1787-1798. [PMID: 28674921 PMCID: PMC5556133 DOI: 10.1007/s00421-017-3675-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Accepted: 06/28/2017] [Indexed: 11/06/2022]
Abstract
PURPOSE The low power output and fatigue resistance during functional electrical stimulation (FES) limits its use for functional applications. The aim of this study was to compare the power output and fatigue properties of spatially distributed sequential stimulation (SDSS) against conventional single electrode stimulation (SES) in an isokinetic knee extension task simulating knee movement during recumbent cycling. METHODS M. vastus lateralis and m. vastus medialis of eight able-bodied subjects were stimulated for 6 min on both legs with both setups. In the SES setup, target muscles were each stimulated by a pair of electrodes. In SDSS, four small electrodes replaced the SES active electrodes, but reference electrodes were the same. Torque was measured during knee extension movement by a dynamometer at an angular velocity of 110°/s. Mean power (P mean) was calculated from stimulated extensions for the first 10 extensions, the final 20 extensions and overall. Fatigue is presented as an index, calculated as the decrease with respect to initial power. RESULTS P mean was significantly higher for SDSS than for SES in the final phase (9.9 ± 4.0 vs. 7.4 ± 4.3 W, p = 0.035) and overall (11.5 ± 4.0 vs. 9.2 ± 4.5 W, p = 0.037). With SDSS, the reduction in P mean was significantly smaller compared to SES (from 14.9 to 9.9 vs. 14.6 to 7.4 W, p = 0.024). The absolute mean pulse width was substantially lower with SDSS (62.5 vs. 90.0 µs). CONCLUSION Although less stimulation was applied, SDSS showed a significantly higher mean power output than SES. SDSS also had improved fatigue resistance when compared to conventional stimulation. The SDSS approach may provide substantial performance benefits for cyclical FES applications.
Collapse
Affiliation(s)
- Marco Laubacher
- Division of Mechanical Engineering, Department of Engineering and Information Technology, Institute for Rehabilitation and Performance Technology, Bern University of Applied Sciences, 3400, Burgdorf, Switzerland.
- Sensory Motor Systems Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland.
| | - Anil Efe Aksöz
- Division of Mechanical Engineering, Department of Engineering and Information Technology, Institute for Rehabilitation and Performance Technology, Bern University of Applied Sciences, 3400, Burgdorf, Switzerland
- Sensory Motor Systems Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Robert Riener
- Sensory Motor Systems Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | | | - Kenneth J Hunt
- Division of Mechanical Engineering, Department of Engineering and Information Technology, Institute for Rehabilitation and Performance Technology, Bern University of Applied Sciences, 3400, Burgdorf, Switzerland
| |
Collapse
|
18
|
Koutsou AD, Moreno JC, del Ama AJ, Rocon E, Pons JL. Advances in selective activation of muscles for non-invasive motor neuroprostheses. J Neuroeng Rehabil 2016; 13:56. [PMID: 27296478 PMCID: PMC4907085 DOI: 10.1186/s12984-016-0165-2] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2016] [Accepted: 06/07/2016] [Indexed: 11/10/2022] Open
Abstract
Non-invasive neuroprosthetic (NP) technologies for movement compensation and rehabilitation remain with challenges for their clinical application. Two of those major challenges are selective activation of muscles and fatigue management. This review discusses how electrode arrays improve the efficiency and selectivity of functional electrical stimulation (FES) applied via transcutaneous electrodes. In this paper we review the principles and achievements during the last decade on techniques for artificial motor unit recruitment to improve the selective activation of muscles. We review the key factors affecting the outcome of muscle force production via multi-pad transcutaneous electrical stimulation and discuss how stimulation parameters can be set to optimize external activation of body segments. A detailed review of existing electrode array systems proposed by different research teams is also provided. Furthermore, a review of the targeted applications of existing electrode arrays for control of upper and lower limb NPs is provided. Eventually, last section demonstrates the potential of electrode arrays to overcome the major challenges of NPs for compensation and rehabilitation of patient-specific impairments.
Collapse
Affiliation(s)
- Aikaterini D. Koutsou
- />Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council, Madrid, Spain
| | - Juan C. Moreno
- />Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council, Madrid, Spain
| | | | - Eduardo Rocon
- />Neural and Cognitive Engineering group, Centro de Automática y Robótica, CAR, Spanish National Research Council, CSIC-UPM, Madrid, Spain
| | - José L. Pons
- />Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council, Madrid, Spain
| |
Collapse
|
19
|
Ibitoye MO, Hamzaid NA, Hasnan N, Abdul Wahab AK, Davis GM. Strategies for Rapid Muscle Fatigue Reduction during FES Exercise in Individuals with Spinal Cord Injury: A Systematic Review. PLoS One 2016; 11:e0149024. [PMID: 26859296 PMCID: PMC4747522 DOI: 10.1371/journal.pone.0149024] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
Background Rapid muscle fatigue during functional electrical stimulation (FES)-evoked muscle contractions in individuals with spinal cord injury (SCI) is a significant limitation to attaining health benefits of FES-exercise. Delaying the onset of muscle fatigue is often cited as an important goal linked to FES clinical efficacy. Although the basic concept of fatigue-resistance has a long history, recent advances in biomedical engineering, physiotherapy and clinical exercise science have achieved improved clinical benefits, especially for reducing muscle fatigue during FES-exercise. This review evaluated the methodological quality of strategies underlying muscle fatigue-resistance that have been used to optimize FES therapeutic approaches. The review also sought to synthesize the effectiveness of these strategies for persons with SCI in order to establish their functional impacts and clinical relevance. Methods Published scientific literature pertaining to the reduction of FES-induced muscle fatigue was identified through searches of the following databases: Science Direct, Medline, IEEE Xplore, SpringerLink, PubMed and Nature, from the earliest returned record until June 2015. Titles and abstracts were screened to obtain 35 studies that met the inclusion criteria for this systematic review. Results Following the evaluation of methodological quality (mean (SD), 50 (6) %) of the reviewed studies using the Downs and Black scale, the largest treatment effects reported to reduce muscle fatigue mainly investigated isometric contractions of limited functional and clinical relevance (n = 28). Some investigations (n = 13) lacked randomisation, while others were characterised by small sample sizes with low statistical power. Nevertheless, the clinical significance of emerging trends to improve fatigue-resistance during FES included (i) optimizing electrode positioning, (ii) fine-tuning of stimulation patterns and other FES parameters, (iii) adjustments to the mode and frequency of exercise training, and (iv) biofeedback-assisted FES-exercise to promote selective recruitment of fatigue-resistant motor units. Conclusion Although the need for further in-depth clinical trials (especially RCTs) was clearly warranted to establish external validity of outcomes, current evidence was sufficient to support the validity of certain techniques for rapid fatigue-reduction in order to promote FES therapy as an integral part of SCI rehabilitation. It is anticipated that this information will be valuable to clinicians and other allied health professionals administering FES as a treatment option in rehabilitation and aid the development of effective rehabilitation interventions.
Collapse
Affiliation(s)
- Morufu Olusola Ibitoye
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
- Department of Biomedical Engineering, Faculty of Engineering and Technology, University of Ilorin, Ilorin, Nigeria
| | - Nur Azah Hamzaid
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
- * E-mail:
| | - Nazirah Hasnan
- Department of Rehabilitation Medicine, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
| | - Ahmad Khairi Abdul Wahab
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - Glen M. Davis
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
- Clinical Exercise and Rehabilitation Unit, Discipline of Exercise and Sport Sciences, Faculty of Health Sciences, The University of Sydney, Sydney, Australia
| |
Collapse
|
20
|
Chalah MA, Lefaucheur JP, Ayache SS. Non-invasive Central and Peripheral Stimulation: New Hope for Essential Tremor? Front Neurosci 2015; 9:440. [PMID: 26635516 PMCID: PMC4649015 DOI: 10.3389/fnins.2015.00440] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2015] [Accepted: 11/01/2015] [Indexed: 12/31/2022] Open
Abstract
Essential tremor (ET) is among the most frequent movement disorders. It usually manifests as a postural and kinematic tremor of the arms, but may also involve the head, voice, lower limbs, and trunk. An oscillatory network has been proposed as a neural correlate of ET, and is mainly composed of the olivocerebellar system, thalamus, and motor cortex. Since pharmacological agents have limited benefits, surgical interventions like deep brain stimulation are the last-line treatment options for the most severe cases. Non-invasive brain stimulation techniques, particularly transcranial magnetic or direct current stimulation, are used to ameliorate ET. Their non-invasiveness, along with their side effects profile, makes them an appealing treatment option. In addition, peripheral stimulation has been applied in the same perspective. Hence, the aim of the present review is to shed light on the emergent use of non-invasive central and peripheral stimulation techniques in this interesting context.
Collapse
Affiliation(s)
- Moussa A Chalah
- EA 4391, Excitabilité Nerveuse et Thérapeutique, Université Paris-Est-Créteil Créteil, France ; Service de Physiologie - Explorations Fonctionnelles, Hôpital Henri Mondor, Assistance Publique - Hôpitaux de Paris Créteil, France
| | - Jean-Pascal Lefaucheur
- EA 4391, Excitabilité Nerveuse et Thérapeutique, Université Paris-Est-Créteil Créteil, France ; Service de Physiologie - Explorations Fonctionnelles, Hôpital Henri Mondor, Assistance Publique - Hôpitaux de Paris Créteil, France
| | - Samar S Ayache
- EA 4391, Excitabilité Nerveuse et Thérapeutique, Université Paris-Est-Créteil Créteil, France ; Service de Physiologie - Explorations Fonctionnelles, Hôpital Henri Mondor, Assistance Publique - Hôpitaux de Paris Créteil, France ; Neurology Division, University Medical Center Rizk Hospital Beirut, Lebanon
| |
Collapse
|
21
|
Sayenko DG, Popovic MR, Masani K. Spatially distributed sequential stimulation reduces muscle fatigue during neuromuscular electrical stimulation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2013:3614-7. [PMID: 24110512 DOI: 10.1109/embc.2013.6610325] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
A critical limitation with neuromuscular electrical stimulation (NMES) approach is the rapid onset of muscle fatigue during repeated contractions, which results in the muscle force decay and slowing of muscle contractile properties. In our previous study, we demonstrated that spatially distributed sequential stimulation (SDSS) show a drastically greater fatigue-reducing ability compared to a conventional, single active electrode stimulation (SES) with an individual with spinal cord injury when applied for plantar flexors. The purpose of the present study is to explore the fatigue-reducing ability of SDSS for major lower limb muscle groups in the able-bodied population as well as individuals with spinal cord injury (SCI). SDSS was delivered through four active electrodes applied to the muscle of interest, sending a stimulation pulse to each electrode one after another with 90° phase shift between successive electrodes. For comparison, SES was delivered through one active electrode. For both modes of stimulation, the resultant frequency to the muscle as a whole was 40 Hz. Using corresponding protocols for the fatiguing stimulation, we demonstrated the fatigue-reducing ability of SDSS by higher fatigue indices as compared with single active electrode setup for major leg muscles in both subject groups. The present work verifies and extends reported findings on the effectiveness of using spatially distributed sequential stimulation in the leg muscles to reduce muscle fatigue. Application of this technique can improve the usefulness of NMES during functional movements in the clinical setup.
Collapse
|
22
|
Malešević NM, Popović Maneski LZ, Ilić V, Jorgovanović N, Bijelić G, Keller T, Popović DB. A multi-pad electrode based functional electrical stimulation system for restoration of grasp. J Neuroeng Rehabil 2012; 9:66. [PMID: 23009589 PMCID: PMC3547757 DOI: 10.1186/1743-0003-9-66] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2012] [Accepted: 09/19/2012] [Indexed: 11/10/2022] Open
Abstract
Background Functional electrical stimulation (FES) applied via transcutaneous electrodes is a common rehabilitation technique for assisting grasp in patients with central nervous system lesions. To improve the stimulation effectiveness of conventional FES, we introduce multi-pad electrodes and a new stimulation paradigm. Methods The new FES system comprises an electrode composed of small pads that can be activated individually. This electrode allows the targeting of motoneurons that activate synergistic muscles and produce a functional movement. The new stimulation paradigm allows asynchronous activation of motoneurons and provides controlled spatial distribution of the electrical charge that is delivered to the motoneurons. We developed an automated technique for the determination of the preferred electrode based on a cost function that considers the required movement of the fingers and the stabilization of the wrist joint. The data used within the cost function come from a sensorized garment that is easy to implement and does not require calibration. The design of the system also includes the possibility for fine-tuning and adaptation with a manually controllable interface. Results The device was tested on three stroke patients. The results show that the multi-pad electrodes provide the desired level of selectivity and can be used for generating a functional grasp. The results also show that the procedure, when performed on a specific user, results in the preferred electrode configuration characteristics for that patient. The findings from this study are of importance for the application of transcutaneous stimulation in the clinical and home environments.
Collapse
|
23
|
Motor unit recruitment during neuromuscular electrical stimulation: a critical appraisal. Eur J Appl Physiol 2011; 111:2399-407. [PMID: 21870119 DOI: 10.1007/s00421-011-2128-4] [Citation(s) in RCA: 213] [Impact Index Per Article: 16.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2011] [Accepted: 08/12/2011] [Indexed: 10/17/2022]
Abstract
Neuromuscular electrical stimulation (NMES) is commonly used in clinical settings to activate skeletal muscle in an effort to mimic voluntary contractions and enhance the rehabilitation of human skeletal muscles. It is also used as a tool in research to assess muscle performance and/or neuromuscular activation levels. However, there are fundamental differences between voluntary- and artificial-activation of motor units that need to be appreciated before NMES protocol design can be most effective. The unique effects of NMES have been attributed to several mechanisms, most notably, a reversal of the voluntary recruitment pattern that is known to occur during voluntary muscle contractions. This review outlines the assertion that electrical stimulation recruits motor units in a nonselective, spatially fixed, and temporally synchronous pattern. Additionally, it synthesizes the evidence that supports the contention that this recruitment pattern contributes to increased muscle fatigue when compared with voluntary actions and provides some commentary on the parameters of electrical stimulation as well as emerging technologies being developed to facilitate NMES implementation. A greater understanding of how electrical stimulation recruits motor units, as well as the benefits and limitations of its use, is highly relevant when using this tool for testing and training in rehabilitation, exercise, and/or research.
Collapse
|
24
|
Popović Maneski L, Jorgovanović N, Ilić V, Došen S, Keller T, Popović MB, Popović DB. Electrical stimulation for the suppression of pathological tremor. Med Biol Eng Comput 2011; 49:1187-93. [PMID: 21755318 DOI: 10.1007/s11517-011-0803-6] [Citation(s) in RCA: 83] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2011] [Accepted: 07/02/2011] [Indexed: 11/28/2022]
Abstract
Pathological tremor is manifested as an involuntary oscillation of one or more body parts. Tremor greatly decreases the quality of life and often prevents the patient from performing daily activities. We hypothesized that sensors-driven multichannel electrical stimulation could stabilize affected joints by activating the antagonistic muscles during involuntary activation of agonist muscles and vice versa (out-of-phase stimulation). Here, we present the new system (hardware and software) and the testing of its operation. The hardware consists of a multichannel stimulator and inertial sensors for feedback. The software implements adaptive sensors-driven control for the out-of-phase stimulation. The system was initially applied to healthy persons at the wrist and elbow joints to test the efficiency of the hardware and software solutions. Predefined rhythmic stimulation resulted in tremulous movement, which subjects could not prevent; yet, they were still able to functionally use their hand. The system was then applied to seven patients with Parkinson's disease and essential tremor for minimization of the wrist joint tremor. In six patients, the adaptive out-of-phase stimulation resulted in a significant decrease in the amplitude of tremor (67 ± 13%). In one patient, the stimulation did not result in the expected reduction of tremor.
Collapse
Affiliation(s)
- Lana Popović Maneski
- School of Electrical Engineering, University of Belgrade, Bulevar kralja Aleksandra 73, 11000, Belgrade, Serbia.
| | | | | | | | | | | | | |
Collapse
|