1
|
Manfredi L. Endorobots for Colonoscopy: Design Challenges and Available Technologies. Front Robot AI 2021; 8:705454. [PMID: 34336938 PMCID: PMC8317132 DOI: 10.3389/frobt.2021.705454] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Accepted: 06/22/2021] [Indexed: 12/12/2022] Open
Abstract
Colorectal cancer (CRC) is the second most common cause of cancer death worldwide, after lung cancer (Sung et al., 2021). Early stage detection is key to increase the survival rate. Colonoscopy remains to be the gold standard procedure due to its dual capability to optically inspect the entire colonic mucosa and to perform interventional procedures at the same time. However, this causes pain and discomfort, whereby it requires sedation or anaesthesia of the patient. It is a difficult procedure to perform that can cause damage to the colonic wall in some cases. Development of new technologies aims to overcome the current limitations on colonoscopy by using advancements in endorobotics research. The design of these advanced medical devices is challenging because of the limited space of the lumen, the contorted shape, and the long tract of the large bowel. The force applied to the colonic wall needs to be controlled to avoid collateral effects such as injuries to the colonic mucosa and pain during the procedure. This article discusses the current challenges in the colonoscopy procedure, the available locomotion technologies for endorobots used in colonoscopy at a prototype level and the commercial products available.
Collapse
Affiliation(s)
- Luigi Manfredi
- Division of Imaging Science and Technology, School of Medicine, University of Dundee, Dundee, United Kingdom
| |
Collapse
|
2
|
Taddese AZ, Slawinski PR, Pirotta M, De Momi E, Obstein KL, Valdastri P. Enhanced Real-Time Pose Estimation for Closed-Loop Robotic Manipulation of Magnetically Actuated Capsule Endoscopes. Int J Rob Res 2018; 37:890-911. [PMID: 30150847 PMCID: PMC6108552 DOI: 10.1177/0278364918779132] [Citation(s) in RCA: 63] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Pose estimation methods for robotically guided magnetic actuation of capsule endoscopes have recently enabled trajectory following and automation of repetitive endoscopic maneuvers. However, these methods face significant challenges in their path to clinical adoption including the presence of regions of magnetic field singularity, where the accuracy of the system degrades, and the need for accurate initialization of the capsule's pose. In particular, the singularity problem exists for any pose estimation method that utilizes a single source of magnetic field if the method does not rely on the motion of the magnet to obtain multiple measurements from different vantage points. We analyze the workspace of such pose estimation methods with the use of the point-dipole magnetic field model and show that singular regions exist in areas where the capsule is nominally located during magnetic actuation. Since the dipole model can approximate most magnetic field sources, the problem discussed herein pertains to a wider set of pose estimation techniques. We then propose a novel hybrid approach employing static and time-varying magnetic field sources and show that this system has no regions of singularity. The proposed system was experimentally validated for accuracy, workspace size, update rate and performance in regions of magnetic singularity. The system performed as well or better than prior pose estimation methods without requiring accurate initialization and was robust to magnetic singularity. Experimental demonstration of closed-loop control of a tethered magnetic device utilizing the developed pose estimation technique is provided to ascertain its suitability for robotically guided capsule endoscopy. Hence, advances in closed-loop control and intelligent automation of magnetically actuated capsule endoscopes can be further pursued toward clinical realization by employing this pose estimation system.
Collapse
Affiliation(s)
- Addisu Z. Taddese
- Science and Technology of Robotics in Medicine (STORM) Laboratory USA, Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Piotr R. Slawinski
- Science and Technology of Robotics in Medicine (STORM) Laboratory USA, Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Marco Pirotta
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Elena De Momi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Keith L. Obstein
- Science and Technology of Robotics in Medicine (STORM) Laboratory USA, Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
- Division of Gastroenterology, Hepatology, and Nutrition, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Pietro Valdastri
- Science and Technology of Robotics in Medicine (STORM) Laboratory UK, School of Electronic and Electrical Engineering, University of Leeds, Leeds, UK
| |
Collapse
|
3
|
Shamsudhin N, Zverev VI, Keller H, Pane S, Egolf PW, Nelson BJ, Tishin AM. Magnetically guided capsule endoscopy. Med Phys 2017; 44:e91-e111. [PMID: 28437000 DOI: 10.1002/mp.12299] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2016] [Revised: 02/22/2017] [Accepted: 04/13/2017] [Indexed: 12/18/2022] Open
Abstract
Wireless capsule endoscopy (WCE) is a powerful tool for medical screening and diagnosis, where a small capsule is swallowed and moved by means of natural peristalsis and gravity through the human gastrointestinal (GI) tract. The camera-integrated capsule allows for visualization of the small intestine, a region which was previously inaccessible to classical flexible endoscopy. As a diagnostic tool, it allows to localize the sources of bleedings in the middle part of the gastrointestinal tract and to identify diseases, such as inflammatory bowel disease (Crohn's disease), polyposis syndrome, and tumors. The screening and diagnostic efficacy of the WCE, especially in the stomach region, is hampered by a variety of technical challenges like the lack of active capsular position and orientation control. Therapeutic functionality is absent in most commercial capsules, due to constraints in capsular volume and energy storage. The possibility of using body-exogenous magnetic fields to guide, orient, power, and operate the capsule and its mechanisms has led to increasing research in Magnetically Guided Capsule Endoscopy (MGCE). This work shortly reviews the history and state-of-art in WCE technology. It highlights the magnetic technologies for advancing diagnostic and therapeutic functionalities of WCE. Not restricting itself to the GI tract, the review further investigates the technological developments in magnetically guided microrobots that can navigate through the various air- and fluid-filled lumina and cavities in the body for minimally invasive medicine.
Collapse
Affiliation(s)
- Naveen Shamsudhin
- Multi-Scale Robotics Lab, Institute of Robotics and Intelligent Systems, ETH Zurich, Zurich, CH 8092, Switzerland
| | - Vladimir I Zverev
- Faculty of Physics, M.V. Lomonosov Moscow State University, Moscow, 119991, Russia
| | - Henrik Keller
- KUKA Roboter GmbH, Zugspitzstrasse 140, Augsburg, 86165, Germany
| | - Salvador Pane
- Multi-Scale Robotics Lab, Institute of Robotics and Intelligent Systems, ETH Zurich, Zurich, CH 8092, Switzerland
| | - Peter W Egolf
- Institute of Thermal Sciences and Engineering, University of Applied Sciences of Western Switzerland, Yverdon-les-Bains, CH 1401, Switzerland
| | - Bradley J Nelson
- Multi-Scale Robotics Lab, Institute of Robotics and Intelligent Systems, ETH Zurich, Zurich, CH 8092, Switzerland
| | - Alexander M Tishin
- Faculty of Physics, M.V. Lomonosov Moscow State University, Moscow, 119991, Russia.,Pharmag LLC, Promyshlennaya st 4, Troitsk, Moscow, 142190, Russia
| |
Collapse
|