Moscoso-Vasquez M, Fabris C, Breton MD. Performance Effect of Adjusting Insulin Sensitivity for Model-Based Automated Insulin Delivery Systems. J Diabetes Sci Technol 2023; 17:1470-1481. [PMID: 37864340 PMCID: PMC10658700 DOI: 10.1177/19322968231206798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/22/2023]
Abstract
BACKGROUND Model predictive control (MPC) has become one of the most popular control strategies for automated insulin delivery (AID) in type 1 diabetes (T1D). These algorithms rely on a prediction model to determine the best insulin dosing every sampling time. Although these algorithms have been shown to be safe and effective for glucose management through clinical trials, managing the ever-fluctuating relationship between insulin delivery and resulting glucose uptake (aka insulin sensitivity, IS) remains a challenge. We aim to evaluate the effect of informing an AID system with IS on the performance of the system. METHOD The University of Virginia (UVA) MPC control-based hybrid closed-loop (HCL) and fully closed-loop (FCL) system was used. One-day simulations at varying levels of IS were run with the UVA/Padova T1D Simulator. The AID system was informed with an estimated value of IS obtained through a mixed meal glucose tolerance test. Relevant controller parameters are updated to inform insulin dosing of IS. Performance of the HCL/FCL system with and without information of the changing IS was assessed using a novel performance metric penalizing the time outside the target glucose range. RESULTS Feedback in AID systems provides a certain degree tolerance to changes in IS. However, IS-informed bolus and basal dosing improve glycemic outcomes, providing increased protection against hyperglycemia and hypoglycemia according to the individual's physiological state. CONCLUSIONS The proof-of-concept analysis presented here shows the potentially beneficial effects on system performance of informing the AID system with accurate estimates of IS. In particular, when considering reduced IS, the informed controller provides increased protection against hyperglycemia compared with the naïve controller. Similarly, reduced hypoglycemia is obtained for situations with increased IS. Further tailoring of the adaptation schemes proposed in this work is needed to overcome the increased hypoglycemia observed in the more resistant cases and to optimize the performance of the adaptation method.
Collapse
Affiliation(s)
| | - Chiara Fabris
- Center for Diabetes Technology,
University of Virginia, Charlottesville, VA, USA
| | - Marc D. Breton
- Center for Diabetes Technology,
University of Virginia, Charlottesville, VA, USA
| |
Collapse
|
2
|
Alamir M. Learning-based sensitivity analysis and feedback design for drug delivery of mixed therapy of cancer in the presence of high model uncertainties. J Theor Biol 2023; 568:111508. [PMID: 37148964 DOI: 10.1016/j.jtbi.2023.111508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 03/29/2023] [Accepted: 04/21/2023] [Indexed: 05/08/2023]
Abstract
In this paper, a methodology is proposed that enables to analyze the sensitivity of the outcome of a therapy to unavoidable high dispersion of the patient specific parameters on one hand and to the choice of the parameters that define the drug delivery feedback strategy on the other hand. More precisely, a method is given that enables to extract and rank the most influent parameters that determine the probability of success/failure of a given feedback therapy for a given set of initial conditions over a cloud of realizations of uncertainties. Moreover predictors of the expectations of the amounts of drugs being used can also be derived. This enables to design an efficient stochastic optimization framework that guarantees safe contraction of the tumor while minimizing a weighted sum of the quantities of the different drugs being used. The framework is illustrated and validated using the example of a mixed therapy of cancer involving three combined drugs namely: a chemotherapy drug, an immunology vaccine and an immunotherapy drug. Finally, in this specific case, it is shown that dash-boards can be built in the 2D-space of the most influent state components that summarize the outcomes' probabilities and the associated drug usage as iso-values curves in the reduced state space.
Collapse
Affiliation(s)
- Mazen Alamir
- Univ. Grenoble Alpes, CNRS, Grenoble INP, GIPSA-lab, 38000 Grenoble, France.
| |
Collapse
|
3
|
Affan A, Zurada JM, Inanc T. Control-Relevant Adaptive Personalized Modeling From Limited Clinical Data for Precise Warfarin Management. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2023; 3:242-251. [PMID: 36846361 PMCID: PMC9955254 DOI: 10.1109/ojemb.2023.3240072] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 10/28/2022] [Accepted: 01/06/2023] [Indexed: 12/26/2023] Open
Abstract
Warfarin is a challenging drug to administer due to the narrow therapeutic index of the International Normalized Ratio (INR), the inter- and intra-variability of patients, limited clinical data, genetics, and the effects of other medications. Goal: To predict the optimal warfarin dosage in the presence of the aforementioned challenges, we present an adaptive individualized modeling framework based on model (In)validation and semi-blind robust system identification. The model (In)validation technique adapts the identified individualized patient model according to the change in the patient's status to ensure the model's suitability for prediction and controller design. Results: To implement the proposed adaptive modeling framework, the clinical data of warfarin-INR of forty-four patients has been collected at the Robley Rex Veterans Administration Medical Center, Louisville. The proposed algorithm is compared with recursive ARX and ARMAX model identification methods. The results of identified models using one-step-ahead prediction and minimum mean squared analysis (MMSE) show that the proposed framework effectively predicts the warfarin dosage to keep the INR values within the desired range and adapt the individualized patient model to exhibit the true status of the patient throughout treatment. Conclusion: This paper proposes an adaptive personalized patient modeling framework from limited patientspecific clinical data. It is shown by rigorous simulations that the proposed framework can accurately predict a patient's doseresponse characteristics and it can alert the clinician whenever identified models are no longer suitable for prediction and adapt the model to the current status of the patient to reduce the prediction error.
Collapse
Affiliation(s)
- Affan Affan
- Electrical and Computer Engineering DepartmentUniversity of LouisvilleLouisvilleKY40292USA
| | - Jacek M. Zurada
- Electrical and Computer Engineering DepartmentUniversity of LouisvilleLouisvilleKY40292USA
- Information Technology InstituteAcademy of Social Sciences90-193LodzPoland
| | - Tamer Inanc
- Electrical and Computer Engineering DepartmentUniversity of LouisvilleLouisvilleKY40292USA
| |
Collapse
|
4
|
Olçomendy L, Cassany L, Pirog A, Franco R, Puginier E, Jaffredo M, Gucik-Derigny D, Ríos H, Ferreira de Loza A, Gaitan J, Raoux M, Bornat Y, Catargi B, Lang J, Henry D, Renaud S, Cieslak J. Towards the Integration of an Islet-Based Biosensor in Closed-Loop Therapies for Patients With Type 1 Diabetes. Front Endocrinol (Lausanne) 2022; 13:795225. [PMID: 35528003 PMCID: PMC9072637 DOI: 10.3389/fendo.2022.795225] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 02/25/2022] [Indexed: 01/01/2023] Open
Abstract
In diabetes mellitus (DM) treatment, Continuous Glucose Monitoring (CGM) linked with insulin delivery becomes the main strategy to improve therapeutic outcomes and quality of patients' lives. However, Blood Glucose (BG) regulation with CGM is still hampered by limitations of algorithms and glucose sensors. Regarding sensor technology, current electrochemical glucose sensors do not capture the full spectrum of other physiological signals, i.e., lipids, amino acids or hormones, relaying the general body status. Regarding algorithms, variability between and within patients remains the main challenge for optimal BG regulation in closed-loop therapies. This work highlights the simulation benefits to test new sensing and control paradigms which address the previous shortcomings for Type 1 Diabetes (T1D) closed-loop therapies. The UVA/Padova T1DM Simulator is the core element here, which is a computer model of the human metabolic system based on glucose-insulin dynamics in T1D patients. That simulator is approved by the US Food and Drug Administration (FDA) as an alternative for pre-clinical testing of new devices and closed-loop algorithms. To overcome the limitation of standard glucose sensors, the concept of an islet-based biosensor, which could integrate multiple physiological signals through electrical activity measurement, is assessed here in a closed-loop insulin therapy. This investigation has been addressed by an interdisciplinary consortium, from endocrinology to biology, electrophysiology, bio-electronics and control theory. In parallel to the development of an islet-based closed-loop, it also investigates the benefits of robust control theory against the natural variability within a patient population. Using 4 meal scenarios, numerous simulation campaigns were conducted. The analysis of their results then introduces a discussion on the potential benefits of an Artificial Pancreas (AP) system associating the islet-based biosensor with robust algorithms.
Collapse
Affiliation(s)
- Loïc Olçomendy
- Univ. Bordeaux, CNRS, Bordeaux INP, IMS, UMR 5218, Talence, France
| | - Louis Cassany
- Univ. Bordeaux, CNRS, Bordeaux INP, IMS, UMR 5218, Talence, France
| | - Antoine Pirog
- Univ. Bordeaux, CNRS, Bordeaux INP, IMS, UMR 5218, Talence, France
| | - Roberto Franco
- Tecnológico Nacional de México/I.T. La Laguna, Torreón, Mexico
| | | | | | | | - Héctor Ríos
- Tecnológico Nacional de México/I.T. La Laguna, Torreón, Mexico
- Cátedras CONACYT, Ciudad de México, Mexico
| | | | - Julien Gaitan
- Univ. Bordeaux, CNRS, CBMN, UMR 5248, Pessac, France
| | | | - Yannick Bornat
- Univ. Bordeaux, CNRS, Bordeaux INP, IMS, UMR 5218, Talence, France
| | - Bogdan Catargi
- Univ. Bordeaux, CNRS, CBMN, UMR 5248, Pessac, France
- Bordeaux Hospitals, Endocrinology and Metabolic Diseases Unit, Bordeaux, France
| | - Jochen Lang
- Univ. Bordeaux, CNRS, CBMN, UMR 5248, Pessac, France
| | - David Henry
- Univ. Bordeaux, CNRS, Bordeaux INP, IMS, UMR 5218, Talence, France
| | - Sylvie Renaud
- Univ. Bordeaux, CNRS, Bordeaux INP, IMS, UMR 5218, Talence, France
| | - Jérôme Cieslak
- Univ. Bordeaux, CNRS, Bordeaux INP, IMS, UMR 5218, Talence, France
- *Correspondence: Jérôme Cieslak,
| |
Collapse
|
5
|
Artificial Pancreas Control Strategies Used for Type 1 Diabetes Control and Treatment: A Comprehensive Analysis. APPLIED SYSTEM INNOVATION 2020. [DOI: 10.3390/asi3030031] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
This paper presents a comprehensive survey about the fundamental components of the artificial pancreas (AP) system including insulin administration and delivery, glucose measurement (GM), and control strategies/algorithms used for type 1 diabetes mellitus (T1DM) treatment and control. Our main focus is on the T1DM that emerges due to pancreas’s failure to produce sufficient insulin due to the loss of beta cells (β-cells). We discuss various insulin administration and delivery methods including physiological methods, open-loop, and closed-loop schemes. Furthermore, we report several factors such as hyperglycemia, hypoglycemia, and many other physical factors that need to be considered while infusing insulin in human body via AP systems. We discuss three prominent control algorithms including proportional-integral- derivative (PID), fuzzy logic, and model predictive, which have been clinically evaluated and have all shown promising results. In addition, linear and non-linear insulin infusion control schemes have been formally discussed. To the best of our knowledge, this is the first work which systematically covers recent developments in the AP components with a solid foundation for future studies in the T1DM field.
Collapse
|