1
|
Ciatto L, Pullia M, Tavilla G, Dauccio B, Messina D, De Cola MC, Quartarone A, Cellini R, Bonanno M, Calabrò RS. Do Patients with Parkinson's Disease Benefit from Dynamic Body Weight Support? A Pilot Study on the Emerging Role of Rysen. Biomedicines 2023; 11:2148. [PMID: 37626645 PMCID: PMC10452686 DOI: 10.3390/biomedicines11082148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 07/27/2023] [Accepted: 07/28/2023] [Indexed: 08/27/2023] Open
Abstract
Parkinson's disease (PD) is a neurodegenerative disorder characterized by motor and non-motor alterations. Typical motor symptoms include resting tremors, bradykinesia (hypokinesia or akinesia), muscular stiffness, gait alterations, and postural instability. In this context, neurorehabilitation may have a pivotal role in slowing the progression of PD, using both conventional and innovative rehabilitation approaches. Thirty patients (15 males and 15 females) affected by PD were enrolled in our study. We randomly divided the patients into two groups, an experimental group (EG) and a control group (CG). In particular, the EG performed gait and balance training using the Rysen system, which is an innovative body weight support (BWS) system, whilst the CG received conventional physiotherapy. Both groups underwent 20 sessions, five times weekly, with each session lasting about 40 min. At the end of the training sessions (T1), we found that both groups (EG and CG) achieved clinical improvements, although the EG showed better scores for post-treatment regarding global motor functioning and postural stability compared to the CG. In conclusion, our results suggest that the Rysen system, which is an innovative BWS tool, could be considered a valid device for improving postural control and global motor functions, when compared to conventional gait training, in patients affected by PD.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | - Mirjam Bonanno
- IRCCS Centro Neurolesi “Bonino-Pulejo”, Via Palermo, C.da Casazza, S.S 113, 98123 Messina, Italy; (L.C.); (M.P.); (G.T.); (B.D.); (D.M.); (M.C.D.C.); (A.Q.); (R.C.); (R.S.C.)
| | | |
Collapse
|
2
|
Takai A, Teramae T, Noda T, Ishihara K, Furukawa JI, Fujimoto H, Hatakenaka M, Fujita N, Jino A, Hiramatsu Y, Miyai I, Morimoto J. Development of split-force-controlled body weight support (SF-BWS) robot for gait rehabilitation. Front Hum Neurosci 2023; 17:1197380. [PMID: 37497041 PMCID: PMC10366359 DOI: 10.3389/fnhum.2023.1197380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 06/15/2023] [Indexed: 07/28/2023] Open
Abstract
This study introduces a body-weight-support (BWS) robot actuated by two pneumatic artificial muscles (PAMs). Conventional BWS devices typically use springs or a single actuator, whereas our robot has a split force-controlled BWS (SF-BWS), in which two force-controlled actuators independently support the left and right sides of the user's body. To reduce the experience of weight, vertical unweighting support forces are transferred directly to the user's left and right hips through a newly designed harness with an open space around the shoulder and upper chest area to allow freedom of movement. A motion capture evaluation with three healthy participants confirmed that the proposed harness does not impede upper-body motion during laterally identical force-controlled partial BWS walking, which is quantitatively similar to natural walking. To evaluate our SF-BWS robot, we performed a force-tracking and split-force control task using different simulated load weight setups (40, 50, and 60 kg masses). The split-force control task, providing independent force references to each PAM and conducted with a 60 kg mass and a test bench, demonstrates that our SF-BWS robot is capable of shifting human body weight in the mediolateral direction. The SF-BWS robot successfully controlled the two PAMs to generate the desired vertical support forces.
Collapse
Affiliation(s)
- Asuka Takai
- Department of Brain Robot Interface, Brain Information Communication Research Laboratory Group, Advanced Telecommunications Research Institute International (ATR), Kyoto, Japan
- Graduate School of Engineering Division of Mechanical Engineering, Osaka Metropolitan University, Osaka, Japan
| | - Tatsuya Teramae
- Department of Brain Robot Interface, Brain Information Communication Research Laboratory Group, Advanced Telecommunications Research Institute International (ATR), Kyoto, Japan
| | - Tomoyuki Noda
- Department of Brain Robot Interface, Brain Information Communication Research Laboratory Group, Advanced Telecommunications Research Institute International (ATR), Kyoto, Japan
| | - Koji Ishihara
- Department of Brain Robot Interface, Brain Information Communication Research Laboratory Group, Advanced Telecommunications Research Institute International (ATR), Kyoto, Japan
| | - Jun-ichiro Furukawa
- Department of Brain Robot Interface, Brain Information Communication Research Laboratory Group, Advanced Telecommunications Research Institute International (ATR), Kyoto, Japan
- Man-Machine Collaboration Research Team, Guardian Robot Project, RIKEN, Kyoto, Japan
| | - Hiroaki Fujimoto
- Neurorehabilitation Research Institute, Morinomiya Hospital, Osaka, Japan
| | - Megumi Hatakenaka
- Neurorehabilitation Research Institute, Morinomiya Hospital, Osaka, Japan
| | - Nobukazu Fujita
- Neurorehabilitation Research Institute, Morinomiya Hospital, Osaka, Japan
| | - Akihiro Jino
- Neurorehabilitation Research Institute, Morinomiya Hospital, Osaka, Japan
| | - Yuichi Hiramatsu
- Neurorehabilitation Research Institute, Morinomiya Hospital, Osaka, Japan
| | - Ichiro Miyai
- Neurorehabilitation Research Institute, Morinomiya Hospital, Osaka, Japan
| | - Jun Morimoto
- Department of Brain Robot Interface, Brain Information Communication Research Laboratory Group, Advanced Telecommunications Research Institute International (ATR), Kyoto, Japan
- Man-Machine Collaboration Research Team, Guardian Robot Project, RIKEN, Kyoto, Japan
- Graduate School of Informatics, Kyoto University, Kyoto, Japan
| |
Collapse
|
3
|
Kim J, Oh S, Jo Y, Moon JH, Kim J. A robotic treadmill system to mimic overground walking training with body weight support. Front Neurorobot 2023; 17:1089377. [PMID: 37359910 PMCID: PMC10288878 DOI: 10.3389/fnbot.2023.1089377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Accepted: 02/21/2023] [Indexed: 06/28/2023] Open
Abstract
Introduction Body weight support overground walking training (BWSOWT) is widely used in gait rehabilitation. However, existing systems require large workspace, complex structure, and substantial installation cost for the actuator, which make those systems inappropriate for the clinical environment. For wide clinical use, the proposed system is based on a self-paced treadmill, and uses an optimized body weight support with frame-based two-wire mechanism. Method The Interactive treadmill was used to mimic overground walking. We opted the conventional DC motors to partially unload the body weight and modified pelvic type harness to allow natural pelvic motion. The performance of the proposed system on the measurement of anterior/posterior position, force control, and pelvic motion was evaluated with 8 healthy subjects during walking training. Results We verified that the proposed system was the cost/space-effective and showed the more accurate anterior/posterior position than motion sensor, comparable force control performance, and natural pelvic motion. Discussion The proposed system is cost/space effective, and able to mimic overground walking training with body weight support. In future work, we will improve the force control performance and optimize the training protocol for wide clinical use.
Collapse
Affiliation(s)
- Jongbum Kim
- Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, Republic of Korea
| | - Seunghue Oh
- Department of Physical Therapy, Uiduk University, Gyeongju-si, Republic of Korea
| | - Yongjin Jo
- Department of Mechanical Engineering, Sungkyunkwan University, Suwon-si, Republic of Korea
| | - James Hyungsup Moon
- Department of Mechanical Engineering, Sungkyunkwan University, Suwon-si, Republic of Korea
| | - Jonghyun Kim
- Department of Mechanical Engineering, Sungkyunkwan University, Suwon-si, Republic of Korea
| |
Collapse
|
4
|
Zhang X, Shang P, Li B. A novel Dynamic Body Weight Support overground co-walker enabling variable unloading ratio and Motion Tracking. Front Neurosci 2023; 17:1188776. [PMID: 37360168 PMCID: PMC10285068 DOI: 10.3389/fnins.2023.1188776] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 05/16/2023] [Indexed: 06/28/2023] Open
Abstract
Dynamic Body Weight Support (BWS) systems have gained attention in recent years for their potential in gait training. However, maintaining a natural gait and vertical unloading have been less explored. In our previous work, we developed a body Motion Tracking (MT) walker that can move with patients. In this study, we introduce a novel Motion Tracking Variable Body Weight Support (MTVBWS) system for overground walkers. This system utilizes Center of Mass (COM) tracking and gait phase detection to not only dynamically support the user's body weight in the vertical direction but also to facilitate movement in all directions. The system achieves this horizontal omnidirectional movement by employing active Mecanum wheels, guided by COM recognition. The validation experiments were implemented with the MT mode, passive mode, and BWS mode in "static," "fixed unloading ratio (FUR)," and "variable unloading ratio (VUR)" settings with unloading force of 20 and 30%. The result shows that, compared to other modes, the proposed system in the MTVBWS mode can reduce the dragging effect in the horizontal plane caused by the walker. Moreover, the unloading force can be adjusted automatically to minimize the fluctuations in the force experienced by each lower limb during the rehabilitation walking training process. In comparison to natural walk, this mode presents smaller force fluctuations for each lower limb.
Collapse
Affiliation(s)
- Xiaoqian Zhang
- Center of Neuroengineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
- Shenzhen Jieshui Medical Technology Co., Ltd., Shenzhen, China
| | - Peng Shang
- Center of Neuroengineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Bing Li
- Department of Spinal Surgery, Liuzhou Worker's Hospital, Liuzhou, China
| |
Collapse
|
5
|
Jabeen S, Baines PM, Harlaar J, Vallery H, Berry A. Reaction moments matter when designing lower-extremity robots for tripping recovery. PLoS One 2023; 18:e0280158. [PMID: 36809378 PMCID: PMC9942996 DOI: 10.1371/journal.pone.0280158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Accepted: 12/21/2022] [Indexed: 02/23/2023] Open
Abstract
Balance recovery after tripping often requires an active adaptation of foot placement. Thus far, few attempts have been made to actively assist forward foot placement for balance recovery employing wearable devices. This study aims to explore the possibilities of active forward foot placement through two paradigms of actuation: assistive moments exerted with the reaction moments either internal or external to the human body, namely 'joint' moments and 'free' moments, respectively. Both paradigms can be applied to manipulate the motion of segments of the body (e.g., the shank or thigh), but joint actuators also exert opposing reaction moments on neighbouring body segments, altering posture and potentially inhibiting tripping recovery. We therefore hypothesised that a free moment paradigm is more effective in assisting balance recovery following tripping. The simulation software SCONE was used to simulate gait and tripping over various ground-fixed obstacles during the early swing phase. To aid forward foot placement, joint moments and free moments were applied either on the thigh to augment hip flexion or on the shank to augment knee extension. Two realizations of joint moments on the hip were simulated, with the reaction moment applied to either the pelvis or the contralateral thigh. The simulation results show that assisting hip flexion with either actuation paradigm on the thigh can result in full recovery of gait with a margin of stability and leg kinematics closely matching the unperturbed case. However, when assisting knee extension with moments on the shank, free moment effectively assist balance but joint moments with the reaction moment on the thigh do not. For joint moments assisting hip flexion, placement of the reaction moment on the contralateral thigh was more effective in achieving the desired limb dynamics than placing the reaction on the pelvis. Poor choice of placement of reaction moments may therefore have detrimental consequences for balance recovery, and removing them entirely (i.e., free moment) could be a more effective and reliable alternative. These results challenge conventional assumptions and may inform the design and development of a new generation of minimalistic wearable devices to promote balance during gait.
Collapse
Affiliation(s)
- Saher Jabeen
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
| | - Patricia M. Baines
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
- * E-mail:
| | - Jaap Harlaar
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
- Department of Orthopedics, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Heike Vallery
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
- Department of Rehabilitation Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Andrew Berry
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
- Department of Rehabilitation Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
6
|
Plooij M, Apte S, Keller U, Baines P, Sterke B, Asboth L, Courtine G, von Zitzewitz J, Vallery H. Neglected physical human-robot interaction may explain variable outcomes in gait neurorehabilitation research. Sci Robot 2021; 6:eabf1888. [PMID: 34550719 DOI: 10.1126/scirobotics.abf1888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
[Figure: see text].
Collapse
Affiliation(s)
- M Plooij
- Department of Biomechanical Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, Netherlands.,Demcon Advanced Mechatronics, Delfttechpark 23, Delft, Netherlands.,Motek, a DIH brand, Hogehilweg 18-C, 1101 CD Amsterdam, Netherlands
| | - S Apte
- Department of Biomechanical Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, Netherlands.,Laboratory of Movement Analysis and Measurement, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - U Keller
- ONWARD, EPFL Innovation Park, Lausanne, Switzerland.,Center for Neuroprosthetics (CNP) Valais, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.,Swiss Children's Rehab, University Children's Hospital Zurich, Affoltern am Albis, Switzerland
| | - P Baines
- Department of Biomechanical Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, Netherlands
| | - B Sterke
- Motek, a DIH brand, Hogehilweg 18-C, 1101 CD Amsterdam, Netherlands.,Department of Rehabilitation Medicine, Erasmus MC, Postbus 2040, 3000 CA Rotterdam, Netherlands
| | - L Asboth
- Center for Neuroprosthetics and Brain Mind Institute, School of Life Sciences, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.,Department of Clinical Neuroscience, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.,Defitech Center for Interventional Neurotherapies (NeuroRestore), EPFL/CHUV/UNIL, Lausanne, Switzerland
| | - G Courtine
- ONWARD, EPFL Innovation Park, Lausanne, Switzerland.,Center for Neuroprosthetics and Brain Mind Institute, School of Life Sciences, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.,Department of Clinical Neuroscience, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.,Defitech Center for Interventional Neurotherapies (NeuroRestore), EPFL/CHUV/UNIL, Lausanne, Switzerland
| | - J von Zitzewitz
- ONWARD, EPFL Innovation Park, Lausanne, Switzerland.,Center for Neuroprosthetics (CNP) Valais, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - H Vallery
- Department of Biomechanical Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, Netherlands.,Department of Rehabilitation Medicine, Erasmus MC, Postbus 2040, 3000 CA Rotterdam, Netherlands
| |
Collapse
|
7
|
van Hedel HJA, Rosselli I, Baumgartner-Ricklin S. Clinical utility of the over-ground bodyweight-supporting walking system Andago in children and youths with gait impairments. J Neuroeng Rehabil 2021; 18:29. [PMID: 33557834 PMCID: PMC7871598 DOI: 10.1186/s12984-021-00827-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2020] [Accepted: 01/22/2021] [Indexed: 01/28/2023] Open
Abstract
Background The Andago is a rehabilitation robot that allows training walking over-ground while providing bodyweight unloading (BWU). We investigated the practicability, acceptability, and appropriateness of the device in children with gait impairments undergoing neurorehabilitation. Concerning appropriateness, we investigated whether (i) stride-to-stride variability of the stride time and inter-joint coordination was higher when walking over-ground in Andago versus treadmill walking, and (ii) activation of antigravity leg muscles decreased with higher levels of BWU. Methods Eighteen children and adolescents with gait impairments participated in three sessions. Practicability was assessed by determining the time needed to get a patient in and out of Andago, the accuracy of the BWU system, and other aspects. Acceptability was assessed by patients responding to questions, while six therapists filled out the System Usability Scale. To determine appropriateness, the participants were equipped with surface electromyography (sEMG) electrodes, electrogoniometers and accelerometers. Various parameters were compared between walking over-ground and on a treadmill, and between walking with three different levels of BWU (median: 20%, 35% and 50% of the bodyweight) over-ground. Results Practicability: the average time needed to get in and out of Andago amounted to 60 s and 16 s, respectively. The BWU system seemed accurate, especially at higher levels. We experienced no technical difficulties and Andago prevented 12 falls. However, participants had difficulties walking through a door without bumping into it. Acceptability: after the second session, nine participants felt safer walking in Andago compared to normal walking, 15 preferred walking in Andago compared to treadmill walking, and all wanted to train again with Andago. Therapists rated the usability of the Andago as excellent. Appropriateness: stride-to-stride variability of stride duration and inter-joint coordination was higher in Andago compared to treadmill walking. sEMG activity was not largely influenced by the levels of BWU investigated in this study, except for a reduced M. Gluteus Medius activity at the highest level of BWU tested. Conclusions The Andago is a practical and well-accepted device to train walking over-ground with BWU in children and adolescents with gait impairments safely. The system allows individual stride-to-stride variability of temporospatial gait parameters without affecting antigravity muscle activity strongly. Trial registration: ClinicalTrials.gov Identifier: NCT03787199.
Collapse
Affiliation(s)
- Hubertus J A van Hedel
- Research Department, Swiss Children's Rehab, University Children's Hospital Zurich, Mühlebergstrasse 104, 8910, Affoltern am Albis, Switzerland. .,Children's Research Centre, University Children's Hospital Zurich, Steinwiesstrasse 75, 8032, Zurich, Switzerland.
| | - Irene Rosselli
- Research Department, Swiss Children's Rehab, University Children's Hospital Zurich, Mühlebergstrasse 104, 8910, Affoltern am Albis, Switzerland.,Department of Health Sciences and Technology (D-HEST), ETH Zurich, Zurich, Switzerland
| | - Sandra Baumgartner-Ricklin
- Research Department, Swiss Children's Rehab, University Children's Hospital Zurich, Mühlebergstrasse 104, 8910, Affoltern am Albis, Switzerland.,Children's Research Centre, University Children's Hospital Zurich, Steinwiesstrasse 75, 8032, Zurich, Switzerland
| |
Collapse
|
8
|
Safety Evaluation and Experimental Study of a New Bionic Muscle Cable-Driven Lower Limb Rehabilitation Robot. SENSORS 2020; 20:s20247020. [PMID: 33302462 PMCID: PMC7764671 DOI: 10.3390/s20247020] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 12/02/2020] [Accepted: 12/04/2020] [Indexed: 12/21/2022]
Abstract
Safety is a significant evaluation index of rehabilitation medical devices and a significant precondition for practical application. However, the safety evaluation of cable-driven rehabilitation robots has not been reported, so this work aims to study the safety evaluation methods and evaluation index of cable-driven rehabilitation robots. A bionic muscle cable (BM cable) is proposed to construct a bionic muscle cable-driven lower limb rehabilitation robot (BM-CDLR). The working principle of the BM-CDLR is introduced. The safety performance factors are defined based on the mechanical analysis of the BM-CDLR. The structural safety evaluation index and the use safety evaluation index of the BM-CDLR are given by comprehensively considering the safety performance factors and a proposed speed influence function. The effect of the structural parameters of the elastic elements in the BM cable on the safety performance factors and safety of the BM-CDLR is analyzed and verified by numerical simulations and experimental studies. The results provide the basis for further study of the compliance control strategy and experiments of the human-machine interaction of the BM-CDLR.
Collapse
|
9
|
Bannwart M, Bayer SL, König Ignasiak N, Bolliger M, Rauter G, Easthope CA. Mediolateral damping of an overhead body weight support system assists stability during treadmill walking. J Neuroeng Rehabil 2020; 17:108. [PMID: 32778127 PMCID: PMC7418206 DOI: 10.1186/s12984-020-00735-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Accepted: 07/28/2020] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND Body weight support systems with three or more degrees of freedom (3-DoF) are permissive and safe environments that provide unloading and allow unrestricted movement in any direction. This enables training of walking and balance control at an early stage in rehabilitation. Transparent systems generate a support force vector that is near vertical at all positions in the workspace to only minimally interfere with natural movement patterns. Patients with impaired balance, however, may benefit from additional mediolateral support that can be adjusted according to their capacity. An elegant solution for providing balance support might be by rendering viscous damping along the mediolateral axis via the software controller. Before use with patients, we evaluated if control-rendered mediolateral damping evokes the desired stability enhancement in able-bodied individuals. METHODS A transparent, cable-driven robotic body weight support system (FLOAT) was used to provide transparent body weight support with and without mediolateral damping to 21 able-bodied volunteers while walking at preferred gait velocity on a treadmill. Stability metrics reflecting resistance to small and large perturbations were derived from walking kinematics and compared between conditions and to free walking. RESULTS Compared to free walking, the application of body weight support per-se resulted in gait alterations typically associated with body weight support, namely increased step length and swing phase. Frontal plane dynamic stability, measured by kinematic variability and nonlinear dynamics of the center of mass, was increased under body weight support, indicating reduced balance requirements in both damped and undamped support conditions. Adding damping to the body weight support resulted in a greater increase of frontal plane stability. CONCLUSION Adding mediolateral damping to 3-DoF body weight support systems is an effective method of increasing frontal plane stability during walking in able-bodied participants. Building on these results, adjustable mediolateral damping could enable therapists to select combinations of unloading and stability specifically for each patient and to adapt this in a task specific manner. This could extend the impact of transparent 3-DoF body weight support systems, enabling training of gait and active balance from an early time point onwards in the rehabilitation process for a wide range of mobility activities of daily life.
Collapse
Affiliation(s)
- M. Bannwart
- Spinal Cord Injury Center, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
- Sensory Motor Systems Laboratory, Department of Health Sciences and Technology, Swiss Federal Institute of Technology, Zurich, Switzerland
| | - S. L. Bayer
- Spinal Cord Injury Center, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | | | - M. Bolliger
- Spinal Cord Injury Center, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - G. Rauter
- Spinal Cord Injury Center, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
- Sensory Motor Systems Laboratory, Department of Health Sciences and Technology, Swiss Federal Institute of Technology, Zurich, Switzerland
- BIROMED-Laboratory, Department of Biomedical Engineering, University of Basel, Basel, Switzerland
| | - C. A. Easthope
- Spinal Cord Injury Center, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
- cereneo Center for Interdisciplinary Research, Vitznau, Switzerland
| |
Collapse
|
10
|
Lemus D, Berry A, Jabeen S, Jayaraman C, Hohl K, van der Helm FCT, Jayaraman A, Vallery H. Controller synthesis and clinical exploration of wearable gyroscopic actuators to support human balance. Sci Rep 2020; 10:10412. [PMID: 32591577 PMCID: PMC7320159 DOI: 10.1038/s41598-020-66760-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Accepted: 05/11/2020] [Indexed: 12/02/2022] Open
Abstract
Gyroscopic actuators are appealing for wearable applications due to their ability to provide overground balance support without obstructing the legs. Multiple wearable robots using this actuation principle have been proposed, but none has yet been evaluated with humans. Here we use the GyBAR, a backpack-like prototype portable robot, to investigate the hypothesis that the balance of both healthy and chronic stroke subjects can be augmented through moments applied to the upper body. We quantified balance performance in terms of each participant's ability to walk or remain standing on a narrow support surface oriented to challenge stability in either the frontal or the sagittal plane. By comparing candidate balance controllers, it was found that effective assistance did not require regulation to a reference posture. A rotational viscous field increased the distance healthy participants could walk along a 30mm-wide beam by a factor of 2.0, compared to when the GyBAR was worn but inactive. The same controller enabled individuals with chronic stroke to remain standing for a factor of 2.5 longer on a narrow block. Due to its wearability and versatility of control, the GyBAR could enable new therapy interventions for training and rehabilitation.
Collapse
Affiliation(s)
- Daniel Lemus
- Department of Biomechanical Engineering, Delft University of Technology, Delft, 2628 CD, The Netherlands
| | - Andrew Berry
- Department of Biomechanical Engineering, Delft University of Technology, Delft, 2628 CD, The Netherlands
| | - Saher Jabeen
- Department of Biomechanical Engineering, Delft University of Technology, Delft, 2628 CD, The Netherlands
| | - Chandrasekaran Jayaraman
- Max Näder Center for Rehabilitation Technologies & Outcomes Research, Shirley Ryan AbilityLab, Chicago, IL, 60611, USA
| | - Kristen Hohl
- Max Näder Center for Rehabilitation Technologies & Outcomes Research, Shirley Ryan AbilityLab, Chicago, IL, 60611, USA
| | - Frans C T van der Helm
- Department of Biomechanical Engineering, Delft University of Technology, Delft, 2628 CD, The Netherlands
| | - Arun Jayaraman
- Max Näder Center for Rehabilitation Technologies & Outcomes Research, Shirley Ryan AbilityLab, Chicago, IL, 60611, USA
| | - Heike Vallery
- Department of Biomechanical Engineering, Delft University of Technology, Delft, 2628 CD, The Netherlands.
| |
Collapse
|
11
|
Simulation of human gait with body weight support: benchmarking models and unloading strategies. J Neuroeng Rehabil 2020; 17:81. [PMID: 32586398 PMCID: PMC7318415 DOI: 10.1186/s12984-020-00697-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2019] [Accepted: 05/21/2020] [Indexed: 11/21/2022] Open
Abstract
Background Gait training with partial body weight support (BWS) has become an established rehabilitation technique. Besides passive unloading mechanisms such as springs or counterweights, also active systems that allow rendering constant or modulated vertical forces have been proposed. However, only pilot studies have been conducted to compare different unloading or modulation strategies, and conducting experimental studies is costly and time-consuming. Simulation models that predict the influence of unloading force on human walking may help select the most promising candidates for further evaluation. However, the reliability of simulation results depends on the chosen gait model. The purpose of this paper is two-fold: First, using human experimental data, we evaluate the accuracy of some of the most prevalent walking models in replicating human walking under the influence of Constant-Force BWS: The Simplest Walking model (SW), the Spring-Loaded Inverted Pendulum model (SLIP) and the Muscle-Reflex (MR) gait model. Second, three realizations of BWS, based on Constant-Force (CF), Counterweight (CW) and Tuned-Spring (TS) approaches, are compared to each other in terms of their influence on gait parameters. Methods We conducted simulations in Matlab/Simulink to model the behaviour of each gait model under all three BWS conditions. Nine simulations were undertaken in total and gait parameter response was analysed in each case. Root mean square error (mrmse) w.r.t human data was used to compare the accuracy of gait models. The metrics of interest were spatiotemporal parameters and the vertical ground reaction forces. To scrutinize the BWS strategies, loss of dynamic similarity was calculated in terms of root mean square difference in gait dynamics (Δgd) with respect to the reference gait under zero unloading. The gait dynamics were characterized by a dimensionless number Modela-w. Results SLIP model showed the lowest mrmse for 6 out of 8 gait parameters and for 1 other, the mrmse value were comparable to the MR model; SW model had the highest mrmse. Out of three BWS strategies, Tuned-Spring strategies led to the lowest Δgd values. Conclusions The results of this work demonstrate the usefulness of gait models for BWS simulation and suggest the SLIP model to be more suitable for BWS simulations than the Simplest Walker and the Muscle-reflex models. Further, the Tuned-Spring approach appears to cause less distortions to the gait pattern than the more established Counterweight and Constant-Force approaches and merits experimental verification.
Collapse
|
12
|
Bannwart M, Rohland E, Easthope CA, Rauter G, Bolliger M. Robotic body weight support enables safe stair negotiation in compliance with basic locomotor principles. J Neuroeng Rehabil 2019; 16:157. [PMID: 31870393 PMCID: PMC6929285 DOI: 10.1186/s12984-019-0631-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Accepted: 12/11/2019] [Indexed: 01/13/2023] Open
Abstract
BACKGROUND After a neurological injury, mobility focused rehabilitation programs intensively train walking on treadmills or overground. However, after discharge, quite a few patients are not able to independently negotiate stairs, a real-world task with high physical and psychological demands and a high injury risk. To decrease fall risk and improve patients' capacity to navigate typical environments, early stair negotiation training can help restore competence and confidence in safe stair negotiation. One way to enable early training in a safe and permissive environment is to unload the patient with a body weight support system. We here investigated if unloaded stair negotiation complies with basic locomotor principles, in terms of enabling performance of a physiological movement pattern with minimal compensation. METHODS Seventeen able-bodied participants were unloaded with 0-50% bodyweight during self-paced ascent and descent of a 4-tread staircase. Spatio-temporal parameters, joint ranges of motion, ground reaction forces and myoelectric activity in the main lower limb muscles of participants were compared between unloading levels. Likelihood ratio tests of separated linear mixed models of the investigated outcomes assessed if unloading affects the parameters in general. Subsequent post-hoc testing revealed which levels of unloading differed from unsupported stair negotiation. RESULTS Unloading affected walking velocity, joint ranges of motion, vertical ground reaction force parameters and myoelectric activity in all investigated muscles for stair ascent and descent while step width and single support duration were only affected during ascent. A reduction with increasing levels of body weight support was seen in walking velocity (0.07-0.12 m/s), ranges of motion of the knee and hip (2-10°), vertical ground reaction force peaks (10-70%) and myoelectric activity (17-70%). An increase with unloading was only seen during ascent for ankle range of motion and tibialis anterior activity at substantial unloading. CONCLUSIONS Body weight support facilitates stair negotiation by providing safety and support against gravity. Although unloading effects are present in most parameters, up to 30% body weight support these changes are small, and no dysfunctional patterns are introduced. Body weight support therefore fulfills all the necessary requirements for early stair negotiation training.
Collapse
Affiliation(s)
- M. Bannwart
- Spinal Cord Injury Center, Balgrist University Hospital, Forchstrasse 340, CH-8008 Zurich, Switzerland
- Sensory Motor Systems Lab, Department of Health Sciences and Technology, Swiss Federal Institute of Technology, Zurich, Switzerland
| | - E. Rohland
- Spinal Cord Injury Center, Balgrist University Hospital, Forchstrasse 340, CH-8008 Zurich, Switzerland
| | - C. A. Easthope
- Spinal Cord Injury Center, Balgrist University Hospital, Forchstrasse 340, CH-8008 Zurich, Switzerland
- Cereneo Center for Interdisciplinary Research, Vitznau, Switzerland
| | - G. Rauter
- Spinal Cord Injury Center, Balgrist University Hospital, Forchstrasse 340, CH-8008 Zurich, Switzerland
- Sensory Motor Systems Lab, Department of Health Sciences and Technology, Swiss Federal Institute of Technology, Zurich, Switzerland
- BIROMED-Lab, Department of Biomedical Engineering, University Basel, Gewerbestrasse 14, CH-4123 Basel, Allschwil Switzerland
| | - M. Bolliger
- Spinal Cord Injury Center, Balgrist University Hospital, Forchstrasse 340, CH-8008 Zurich, Switzerland
| |
Collapse
|
13
|
Biarticular muscles are most responsive to upper-body pitch perturbations in human standing. Sci Rep 2019; 9:14492. [PMID: 31601860 PMCID: PMC6787002 DOI: 10.1038/s41598-019-50995-3] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Accepted: 09/23/2019] [Indexed: 11/08/2022] Open
Abstract
Balancing the upper body is pivotal for upright and efficient gait. While models have identified potentially useful characteristics of biarticular thigh muscles for postural control of the upper body, experimental evidence for their specific role is lacking. Based on theoretical findings, we hypothesised that biarticular muscle activity would increase strongly in response to upper-body perturbations. To test this hypothesis, we used a novel Angular Momentum Perturbator (AMP) that, in contrast to existing methods, perturbs the upper-body posture with only minimal effect on Centre of Mass (CoM) excursions. The impulse-like AMP torques applied to the trunk of subjects resulted in upper-body pitch deflections of up to 17° with only small CoM excursions below 2 cm. Biarticular thigh muscles (biceps femoris long head and rectus femoris) showed the strongest increase in muscular activity (mid- and long-latency reflexes, starting 100 ms after perturbation onset) of all eight measured leg muscles which highlights the importance of biarticular muscles for restoring upper-body balance. These insights could be used for improving technological aids like rehabilitation or assistive devices, and the effectiveness of physical training for fall prevention e.g. for elderly people.
Collapse
|
14
|
Kim J, Oh S, Kim J, Kim J. A two-wire body weight support system for interactive treadmill. IEEE Int Conf Rehabil Robot 2019; 2019:349-354. [PMID: 31374654 DOI: 10.1109/icorr.2019.8779549] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Body weight support (BWS) system is widely used for patients to help their gait training. However, that existing systems require large workspace and elastic component in actuation makes the systems inappropriate for wide clinical use. The interactive treadmill was reported to be cost/space effectively simulate overground walking, but there was no suitable BWS system for the treadmill. We proposed a new concept of body weight support system for interactive treadmill. For wide clinical use, we applied a two-wire driven mechanism with simple actuator and a custom pelvic-type harness. With three healthy subjects, the performance of the proposed BWS system on unloading force control was evaluated, and the result showed that the feasibility of the proposed BWS system.
Collapse
|
15
|
Easthope CS, Traini LR, Awai L, Franz M, Rauter G, Curt A, Bolliger M. Overground walking patterns after chronic incomplete spinal cord injury show distinct response patterns to unloading. J Neuroeng Rehabil 2018; 15:102. [PMID: 30419945 PMCID: PMC6233558 DOI: 10.1186/s12984-018-0436-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Accepted: 10/15/2018] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND Body weight support (BWS) is often provided to incomplete spinal cord injury (iSCI) patients during rehabilitation to enable gait training before full weight-bearing is recovered. Emerging robotic devices enable BWS during overground walking, increasing task-specificity of the locomotor training. However, in contrast to a treadmill setting, there is little information on how unloading is integrated into overground locomotion. We investigated the effect of a transparent multi-directional BWS system on overground walking patterns at different levels of unloading in individuals with chronic iSCI (CiSCI) compared to controls. METHODS Kinematics of 12 CiSCI were analyzed at six different BWS levels from 0 to 50% body weight unloading during overground walking at 2kmh- 1 and compared to speed-matched controls. RESULTS In controls, temporal parameters, single joint trajectories, and intralimb coordination responded proportionally to the level of unloading, while spatial parameters remained unaffected. In CiSCI, unloading induced similar changes in temporal parameters. CiSCI, however, did not adapt their intralimb coordination or single joint trajectories to the level of unloading. CONCLUSIONS The findings revealed that continuous, dynamic unloading during overground walking results in subtle and proportional gait adjustments corresponding to changes in body load. CiSCI demonstrated diminished responses in specific domains of gait, indicating that their altered neural processing impeded the adjustment to environmental constraints. CiSCI retain their movement patterns under overground unloading, indicating that this is a viable locomotor therapy tool that may also offer a potential window on the diminished neural control of intralimb coordination.
Collapse
Affiliation(s)
| | - Luca Renato Traini
- Spinal Cord Injury Center, Balgrist University Hospital, Forchstrasse 340, CH-8008, Zürich, Switzerland
| | - Lea Awai
- Spinal Cord Injury Center, Balgrist University Hospital, Forchstrasse 340, CH-8008, Zürich, Switzerland.,Sobell Department of Motor Neuroscience and Movement Disorders, University College London, London, UK
| | - Martina Franz
- Spinal Cord Injury Center, Balgrist University Hospital, Forchstrasse 340, CH-8008, Zürich, Switzerland
| | - Georg Rauter
- BIROMED-Lab, Department of Biomedical Engineering, University Basel, Basel, Switzerland
| | - Armin Curt
- Spinal Cord Injury Center, Balgrist University Hospital, Forchstrasse 340, CH-8008, Zürich, Switzerland
| | - Marc Bolliger
- Spinal Cord Injury Center, Balgrist University Hospital, Forchstrasse 340, CH-8008, Zürich, Switzerland
| |
Collapse
|