1
|
Chew LA, Iannaccone A. Gene-agnostic approaches to treating inherited retinal degenerations. Front Cell Dev Biol 2023; 11:1177838. [PMID: 37123404 PMCID: PMC10133473 DOI: 10.3389/fcell.2023.1177838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Accepted: 03/31/2023] [Indexed: 05/02/2023] Open
Abstract
Most patients with inherited retinal degenerations (IRDs) have been waiting for treatments that are "just around the corner" for decades, with only a handful of seminal breakthroughs happening in recent years. Highlighting the difficulties in the quest for curative therapeutics, Luxturna required 16 years of development before finally obtaining United States Food and Drug Administration (FDA) approval and its international equivalents. IRDs are both genetically and phenotypically heterogeneous. While this diversity offers many opportunities for gene-by-gene precision medicine-based approaches, it also poses a significant challenge. For this reason, alternative (or parallel) strategies to identify more comprehensive, across-the-board therapeutics for the genetically and phenotypically diverse IRD patient population are very appealing. Even when gene-specific approaches may be available and become approved for use, many patients may have reached a disease stage whereby these approaches may no longer be viable. Thus, alternate visual preservation or restoration therapeutic approaches are needed at these stages. In this review, we underscore several gene-agnostic approaches that are being developed as therapeutics for IRDs. From retinal supplementation to stem cell transplantation, optogenetic therapy and retinal prosthetics, these strategies would bypass at least in part the need for treating every individual gene or mutation or provide an invaluable complement to them. By considering the diverse patient population and treatment strategies suited for different stages and patterns of retinal degeneration, gene agnostic approaches are very well poised to impact favorably outcomes and prognosis for IRD patients.
Collapse
Affiliation(s)
- Lindsey A. Chew
- Duke Center for Retinal Degenerations and Ophthalmic Genetic Diseases, Department of Ophthalmology, Duke Eye Center, Duke University School of Medicine, Durham, NC, United States
- Department of Cell Biology, Duke University School of Medicine, Durham, NC, United States
| | - Alessandro Iannaccone
- Duke Center for Retinal Degenerations and Ophthalmic Genetic Diseases, Department of Ophthalmology, Duke Eye Center, Duke University School of Medicine, Durham, NC, United States
| |
Collapse
|
2
|
Di Patrizio Stanchieri G, De Marcellis A, Battisti G, Faccio M, Palange E, Constandinou TG. A Multilevel Synchronized Optical Pulsed Modulation for High Efficiency Biotelemetry. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:1313-1324. [PMID: 36155429 DOI: 10.1109/tbcas.2022.3209542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The paper describes the design, implementation, and characterization of a novel multilevel synchronized pulse position modulation paradigm for high efficiency optical biotelemetry links. The entire optoelectronic architecture has been designed with the aim to improve the efficiency of the data transmission and decrease the overall power consumption that are key factors for the fabrication of implantable and wearable medical devices. By employing specially designed digital architectures, the proposed modulation technique automatically transmits more than one bit per symbol together with the reference clock signal enabling the decoding process of the received coded data. In the present case, the paper demonstrates the capability of the modulation technique to transmit symbols composed by 3 and 4 bits. This has been achieved by developing a prototype of an optical biotelemetry system implemented on an FPGA board that, making use of 500 ps laser pulses, operates under the following two working conditions: (i) 40 MHz clock signal corresponding to a baud rate of 40 Mega symbol per second for symbols composed by 3 bits; (ii) 30 MHz clock signal corresponding to a baud rate of 30 Mega symbol per second for symbols composed by 4 bits. Thus, for both these two configurations the transmission data rate is 120 Mbps and the measured BER was lower than 10-10. Finally, the power consumption was found to be 1.95 and 1.8 mW and the resulting energy efficiencies were 16.25 and 15 pJ/bit for transmitted symbols composed by 3 and 4 bits/symbol, respectively.
Collapse
|
3
|
Wang X, Yu C, Wu Y, Wang J. Structure Design of Quadrilateral Overlapped Wireless Power Transmission Coupling Coil. SENSORS (BASEL, SWITZERLAND) 2022; 22:5955. [PMID: 36015718 PMCID: PMC9415458 DOI: 10.3390/s22165955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2022] [Revised: 08/05/2022] [Accepted: 08/06/2022] [Indexed: 06/15/2023]
Abstract
The application of wireless power transmission technology is becoming more and more extensive. However, in practical applications, the problem of reducing the energy transmission efficiency caused by the offset of the coupling coil needs to be solved urgently. Changing the coil structure is a widely adopted method to deal with this problem. Based on the characteristics of the existing magnetic coupling resonant wireless power transmission system and the principle of the anti-offset coil, this paper innovatively designs a new type of quadrilateral overlapping wireless power transfer coupling coil, which has a strong anti-offset capability. The new type of coil model was built in the simulation and experiment, and the relevant parameters were measured. Experimental results verify that the proposed coil structure has an excellent anti-offset capability.
Collapse
|
4
|
Valente V. Evolution of Biotelemetry in Medical Devices: From Radio Pills to mm-Scale Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:580-599. [PMID: 35834463 DOI: 10.1109/tbcas.2022.3190767] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The advent of semiconductor technology in the mid-20th century created unprecedented opportunities to develop a new generation of small-scale wireless medical sensing devices that can support remote monitoring of patients' vital signs. The first radio pills were developed as early as the 1950's using only a few transistors. These swallowable capsules could sense and wirelessly transmit vital parameters from inside the human body. Since then we have witnessed the rapid progress of medical devices driven by the evolution of semiconductor technology, from single-transistor oscillators to complex mixed-signal multi-channel and multi-modal systems. This paper retraces the evolution of biotelemetry devices from their very early inception to the smart miniaturized systems of modern days, focusing on semiconductor-enabled sensing methods and circuits developed over the last six decades. The paper also includes the author's perspective on current and future trends in the development of CMOS-based biotelemeters, focusing on concepts of implant modularity, miniaturization and hybrid energy harvesting solutions.
Collapse
|
5
|
Lee HS, Ahn J, Kang M, Lee HM. A Load-Insensitive Hybrid LSK Back Telemetry System With Slope-Based Demodulation for Inductively Powered Biomedical Devices. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:651-663. [PMID: 35853074 DOI: 10.1109/tbcas.2022.3192248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
This paper presents a hybrid load-shift keying (LSK) modulation for a load-insensitive back telemetry system to realize near-constant voltage changes in a primary coil (L1) against a wide range of load variations. The hybrid-LSK-enabled full-wave rectifier enables the sequential combination of open- and short-coil functions for hybrid-LSK modulation in addition to wireless power conversion operation. Load-insensitive L1 voltage changes can be demodulated using the proposed slope- based demodulator, which utilizes the threshold slope of L1 voltage changes over the back data pulse width, enabling robust data recovery regardless of the load conditions. The 0.56-mm2 0.18-μm standard CMOS hybrid-LSK prototype demonstrated that the variation of L1 voltage changes could be minimized to 60 mV under load changes between 50 Ω and 50 kΩ at coil separation distance of 10 mm, achieving 88.2% reduction compared to the conventional short-coil LSK with 510 mV variation. The proposed back telemetry system also achieved a bit error rate (BER) of < 9.1 × 10-10 under load ranges from 50 Ω to 50 kΩ and data rate of 1 Mbps, ensuring reliable back data recovery against load variations.
Collapse
|
6
|
Kim HJ, Ho JS. Wireless interfaces for brain neurotechnologies. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2022; 380:20210020. [PMID: 35658679 DOI: 10.1098/rsta.2021.0020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 12/13/2021] [Indexed: 06/15/2023]
Abstract
Wireless interfaces enable brain-implanted devices to remotely interact with the external world. They are critical components in modern research and clinical neurotechnologies and play a central role in determining their overall size, lifetime and functionality. Wireless interfaces use a wide range of modalities-including radio-frequency fields, acoustic waves and light-to transfer energy and data to and from an implanted device. These forms of energy interact with living tissue through distinct mechanisms and therefore lead to systems with vastly different form factors, operating characteristics, and safety considerations. This paper reviews recent advances in the development of wireless interfaces for brain neurotechnologies. We summarize the requirements that state-of-the-art brain-implanted devices impose on the wireless interface, and discuss the working principles and applications of wireless interfaces based on each modality. We also investigate challenges associated with wireless brain neurotechnologies and discuss emerging solutions permitted by recent developments in electrical engineering and materials science. This article is part of the theme issue 'Advanced neurotechnologies: translating innovation for health and well-being'.
Collapse
Affiliation(s)
- Han-Joon Kim
- Department of Electrical and Computer Engineering National University of Singapore, Queenstown, Singapore
| | - John S Ho
- Department of Electrical and Computer Engineering National University of Singapore, Queenstown, Singapore
- The N.1 Institute for Health National University of Singapore, Queenstown, Singapore
- Institute for Health Innovation and Technology, National University of Singapore, Queenstown, Singapore
| |
Collapse
|
7
|
Frederick RA, Troyk PR, Cogan S. Wireless Transmission of Voltage Transients from a Chronically Implanted Neural Stimulation Device. J Neural Eng 2022; 19. [PMID: 35378519 DOI: 10.1088/1741-2552/ac63ea] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Accepted: 04/04/2022] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Consistent transmission of data from wireless neural devices is critical for monitoring the condition and performance of stimulation electrodes. To date, no wireless neural interface has demonstrated the ability to monitor the integrity of chronically implanted electrodes through wireless data transmission. APPROACH In this work, we present a method for wirelessly recording the voltage transient (VT) response to constant-current, cathodic-first asymmetric pulsing from a microelectrode array. We implanted six wireless devices in rat sciatic nerve and wirelessly recorded voltage transient measurements throughout a 38-week implantation period. MAIN RESULTS Electrode maximum cathodic potential excursion (Emc), access voltage, and driving voltage (extracted from each VT) remained stable throughout the 38-week study period. Average Emc(from an applied +0.6 V interpulse bias) in response to 4.7 µA, 200.2 µs pulses was 267 ± 107 mV at week 1 post-implantation and 282 ± 52 mV at week 38 post-implantation. Access voltage for the same 4.7 µA pulsing amplitude was 239 ± 65 mV at week 1 post-implantation and 268 ± 139 mV at week 38 post-implantation. SIGNIFICANCE The voltage transient response recorded via reverse telemetry from the wireless microelectrode array did not significantly change over a 38-week implantation period and was similar to previously reported VTs from wired microelectrodes with the same geometry. Additionally, the voltage transient response recorded wirelessly in phosphate buffered saline before and after device implantation appeared as expected, showing significantly less electrode polarization and smaller access voltage than the VT response in vivo.
Collapse
Affiliation(s)
- Rebecca Anne Frederick
- Bioengineering, The University of Texas at Dallas Erik Jonsson School of Engineering and Computer Science, 800 W. Campbell Rd., Richardson, Texas, 75080-3021, UNITED STATES
| | - Philip R Troyk
- Department of Biomedical Engineering, Illinois Institute of Technology Armour College of Engineering, 3255 S. Dearborn - WH314, Chicago, Illinois, 60616-3793, UNITED STATES
| | - Stuart Cogan
- Department of Bioengineering, University of Texas at Dallas Erik Jonsson School of Engineering and Computer Science, 800 West Campbell Road, Richardson, Texas, 75080-3021, UNITED STATES
| |
Collapse
|
8
|
Fernández E, Alfaro A, Soto-Sánchez C, González-López P, Lozano Ortega AM, Peña S, Grima MD, Rodil A, Gómez B, Chen X, Roelfsema PR, Rolston JD, Davis TS, Normann RA. Visual percepts evoked with an Intracortical 96-channel microelectrode array inserted in human occipital cortex. J Clin Invest 2021; 131:151331. [PMID: 34665780 DOI: 10.1172/jci151331] [Citation(s) in RCA: 64] [Impact Index Per Article: 21.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Accepted: 09/28/2021] [Indexed: 01/11/2023] Open
Abstract
BACKGROUND A long-held dream of scientists is to transfer information directly to the visual cortex of blind individuals, thereby restoring a rudimentary form of sight. However, no clinically available cortical visual prosthesis yet exists. METHODS We implanted an intracortical microelectrode array consisting of 96 electrodes in the visual cortex of a 57-year-old person with complete blindness for a six- month period. We measured thresholds and the characteristics of the visual percepts elicited by intracortical microstimulation. RESULTS Implantation and subsequent explantation of intracortical microelectrodes were carried out without complications. The mean stimulation threshold for single electrodes was 66.8 ± 36.5 μA. We consistently obtained high-quality recordings from visually deprived neurons and the stimulation parameters remained stable over time. Simultaneous stimulation via multiple electrodes were associated with a significant reduction in thresholds (p<0.001, ANOVA test) and evoked discriminable phosphene percepts, allowing the blind participant to identify some letters and recognize object boundaries. Furthermore, we observed a learning process that helped the subject to recognize complex patterns over time. CONCLUSIONS Our results demonstrate the safety and efficacy of chronic intracortical microstimulation via a large number of electrodes in human visual cortex, showing its high potential for restoring functional vision in the blind. TRIAL REGISTRATION ClinicalTrials.gov identifier NCT02983370. FUNDING Funding was provided by grant RTI2018-098969-B-100 from the Spanish Ministerio de Ciencia Innovación y Universidades, by grant PROMETEO/2019/119 from the Generalitat Valenciana (Spain), by the Bidons Egara Research Chair of the University Miguel Hernández (Spain) and by the John Moran Eye Center of the University of Utah (US).
Collapse
Affiliation(s)
| | - Arantxa Alfaro
- Servicio de Neurología, Hospital Vega Baja, Elche, Spain
| | | | - Pablo González-López
- Servicio de Neurología, Hospital General Universitario de Alicante, Alicante, Spain
| | | | - Sebastian Peña
- Bioengineering Institute, University Miguel Hernandez, Elche, Spain
| | | | - Alfonso Rodil
- Bioengineering Institute, University Miguel Hernandez, Elche, Spain
| | - Bernardeta Gómez
- Bioengineering Institute, University Miguel Hernandez, Elche, Spain
| | - Xing Chen
- Department of Vision & Cognition, Netherland Institute for Neuroscience, Amsterdam, Netherlands
| | - Pieter R Roelfsema
- Department of Vision & Cognition, Netherland Institute for Neuroscience, Amsterdam, Netherlands
| | - John D Rolston
- Department of Neurosurgery and Biomedical Engineering, University of Utah, Salt Lake City, United States of America
| | - Tyler S Davis
- Department of Neurosurgery and Biomedical Engineering, University of Utah, Salt Lake City, United States of America
| | - Richard A Normann
- John Moran Eye Center and Biomedical Engineering, University of Utah, Salt Lake City, United States of America
| |
Collapse
|
9
|
Frederick RA, Troyk PR, Cogan SF. Wireless microelectrode arrays for selective and chronically stable peripheral nerve stimulation for hindlimb movement. J Neural Eng 2021; 18:10.1088/1741-2552/ac2bb8. [PMID: 34592725 PMCID: PMC10685740 DOI: 10.1088/1741-2552/ac2bb8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 09/30/2021] [Indexed: 11/12/2022]
Abstract
Objective. Maximizing the stability of implanted neural interfaces will be critical to developing effective treatments for neurological and neuromuscular disorders. Our research aims to develop a stable neural interface using wireless communication and intrafascicular microelectrodes to provide highly selective stimulation of neural tissue.Approach. We implanted a wireless floating microelectrode array into the left sciatic nerve of six rats. Over a 38 week implantation period, we recorded stimulation thresholds and movements evoked at each implanted electrode. We also tracked each animal's response to sensory stimuli and performance on two different walking tasks.Main results. Presence of the microelectrode array inside the sciatic nerve did not cause any obvious motor or sensory deficits in the hindlimb. Visible movement in the hindlimb was evoked by stimulating the sciatic nerve with currents as low as 4.1µA. Thresholds for most of the 96 electrodes we implanted were below 20µA, and predictable recruitment of plantar flexion and dorsiflexion was achieved by stimulating rat sciatic nerve with the intrafascicular microelectrode array. Further, motor recruitment patterns for each electrode did not change significantly throughout the study.Significance. Incorporating wireless communication and a low-profile neural interface facilitated highly stable motor recruitment thresholds and fine motor control in the hindlimb throughout an extensive 9.5 month assessment in rodent peripheral nerve. Results of this study indicate that use of the wireless device tested here could be extended to other applications requiring selective neural stimulation and chronic implantation.
Collapse
Affiliation(s)
- Rebecca A Frederick
- Bioengineering Department, The University of Texas at Dallas, Richardson, TX, United States of America
| | - Philip R Troyk
- Biomedical Engineering Department, Illinois Institute of Technology, Chicago, IL, United States of America
| | - Stuart F Cogan
- Bioengineering Department, The University of Texas at Dallas, Richardson, TX, United States of America
| |
Collapse
|
10
|
Pio-Lopez L, Poulkouras R, Depannemaecker D. Visual cortical prosthesis: an electrical perspective. J Med Eng Technol 2021; 45:394-407. [PMID: 33843427 DOI: 10.1080/03091902.2021.1907468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
The electrical stimulation of the visual cortices has the potential to restore vision to blind individuals. Until now, the results of visual cortical prosthetics have been limited as no prosthesis has restored a full working vision but the field has shown a renewed interest these last years, thanks to wireless and technological advances. However, several scientific and technical challenges are still open to achieve the therapeutic benefit expected by these new devices. One of the main challenges is the electrical stimulation of the brain itself. In this review, we analyse the results in electrode-based visual cortical prosthetics from the electrical point of view. We first describe what is known about the electrode-tissue interface and safety of electrical stimulation. Then we focus on the psychophysics of prosthetic vision and the state-of-the-art on the interplay between the electrical stimulation of the visual cortex and the phosphene perception. Lastly, we discuss the challenges and perspectives of visual cortex electrical stimulation and electrode array design to develop the new generation implantable cortical visual prostheses.
Collapse
Affiliation(s)
| | - Romanos Poulkouras
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, Gardanne, France.,Institut de Neurosciences de la Timone, UMR 7289, CNRS, Aix-Marseille Université, Marseille, France
| | - Damien Depannemaecker
- Department of Integrative and Computational Neuroscience, Paris-Saclay Institute of Neuroscience, Centre National de la Recherche Scientifique, Gif-sur-Yvette, France
| |
Collapse
|
11
|
Ashton MD, Appen IC, Firlak M, Stanhope NE, Schmidt CE, Eisenstadt WR, Hur B, Hardy JG. Wirelessly triggered bioactive molecule delivery from degradable electroactive polymer films. POLYM INT 2020. [DOI: 10.1002/pi.6089] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Mark D Ashton
- Department of Chemistry Lancaster University Lancaster UK
| | - Isabel C Appen
- Department of Chemistry Lancaster University Lancaster UK
| | - Melike Firlak
- Department of Chemistry Lancaster University Lancaster UK
- Department of Chemistry Gebze Technical University Kocaeli Turkey
| | | | - Christine E Schmidt
- J. Crayton Pruitt Family Department of Biomedical Engineering University of Florida, Biomedical Sciences Building JG‐53 Gainesville FL USA
| | - William R Eisenstadt
- Department of Electrical and Computer Engineering University of Florida, New Engineering Building Gainesville FL USA
| | - Byul Hur
- Department of Engineering Technology and Industrial Distribution Texas A&M University College Station TX USA
| | - John G Hardy
- Department of Chemistry Lancaster University Lancaster UK
- J. Crayton Pruitt Family Department of Biomedical Engineering University of Florida, Biomedical Sciences Building JG‐53 Gainesville FL USA
- Materials Science Institute, Lancaster University Lancaster UK
| |
Collapse
|
12
|
De Marcellis A, Stanchieri GDP, Faccio M, Palange E, Constandinou TG. A 300 Mbps 37 pJ/bit Pulsed Optical Biotelemetry. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2020; 14:441-451. [PMID: 32054584 DOI: 10.1109/tbcas.2020.2972733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
This article reports an implantable transcutaneous telemetry for a brain machine interface that uses a novel optical communication system to achieve a highly energy-efficient link. Based on an pulse-based coding scheme, the system uses sub-nanosecond laser pulses to achieve data rates up to 300 Mbps with relatively low power levels when compared to other methods of wireless communication. This has been implemented using a combination of discrete components (semiconductor laser and driver, fast-response Si photodiode and interface) integrated at board level together with reconfigurable logic (encoder, decoder and processing circuits implemented using Xilinx KCU105 board with Kintex UltraScale FPGA). Experimental validation has been performed using a tissue sample that achieves representative level of attenuation/scattering (porcine skin) in the optical path. Results reveal that the system can operate at data rates up to 300 Mbps with a bit error rate (BER) of less than 10 -10, and an energy efficiency of 37 pJ/bit. This can communicate, for example, 1,024 channels of broadband neural data sampled at 18 kHz, 16-bit with only 11 mW power consumption.
Collapse
|
13
|
Niketeghad S, Pouratian N. Brain Machine Interfaces for Vision Restoration: The Current State of Cortical Visual Prosthetics. Neurotherapeutics 2019; 16:134-143. [PMID: 30194614 PMCID: PMC6361050 DOI: 10.1007/s13311-018-0660-1] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
Loss of vision alters the day to day life of blind individuals and may impose a significant burden on their family and the economy. Cortical visual prosthetics have been shown to have the potential of restoring a useful degree of vision via stimulation of primary visual cortex. Due to current advances in electrode design and wireless power and data transmission, development of these prosthetics has gained momentum in the past few years and multiple sites around the world are currently developing and testing their designs. In this review, we briefly outline the visual prosthetic approaches and describe the history of cortical visual prosthetics. Next, we focus on the state of the art of cortical visual prosthesis by briefly explaining the design of current devices that are either under development or in the clinical testing phase. Lastly, we shed light on the challenges of each design and provide some potential solutions.
Collapse
Affiliation(s)
- Soroush Niketeghad
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Nader Pouratian
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA.
- Department of Neurosurgery, University of California Los Angeles, Los Angeles, CA, USA.
| |
Collapse
|
14
|
An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode. SENSORS 2017; 18:s18010001. [PMID: 29267230 PMCID: PMC5795569 DOI: 10.3390/s18010001] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Revised: 12/15/2017] [Accepted: 12/15/2017] [Indexed: 12/02/2022]
Abstract
Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS) components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC)-compliant power transmission circuit, a medical implant communication service (MICS)-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time.
Collapse
|
15
|
Crosstalk Study of Simultaneous Wireless Power/Information Transmission Based on an LCC Compensation Network. ENERGIES 2017. [DOI: 10.3390/en10101606] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
16
|
Mao S, Wang H, Zhu C, Mao ZH, Sun M. Simultaneous Wireless Power Transfer and Data Communication Using Synchronous Pulse-Controlled Load Modulation. MEASUREMENT : JOURNAL OF THE INTERNATIONAL MEASUREMENT CONFEDERATION 2017; 109:316-325. [PMID: 29203949 PMCID: PMC5710816 DOI: 10.1016/j.measurement.2017.05.068] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Wireless Power Transfer (WPT) and wireless data communication are both important problems of research with various applications, especially in medicine. However, these two problems are usually studied separately. In this work, we present a joint study of both problems. Most medical electronic devices, such as smart implants, must have both a power supply to allow continuous operation and a communication link to pass information. Traditionally, separate wireless channels for power transfer and communication are utilized, which complicate the system structure, increase power consumption and make device miniaturization difficult. A more effective approach is to use a single wireless link with both functions of delivering power and passing information. We present a design of such a wireless link in which power and data travel in opposite directions. In order to aggressively miniaturize the implant and reduce power consumption, we eliminate the traditional multi-bit Analog-to-Digital Converter (ADC), digital memory and data transmission circuits all together. Instead, we use a pulse stream, which is obtained from the original biological signal, by a sigma-delta converter and an edge detector, to alter the load properties of the WPT channel. The resulting WPT signal is synchronized with the load changes therefore requiring no memory elements to record inter-pulse intervals. We take advantage of the high sensitivity of the resonant WPT to the load change, and the system dynamic response is used to transfer each pulse. The transient time of the WPT system is analyzed using the coupling mode theory (CMT). Our experimental results show that the memoryless approach works well for both power delivery and data transmission, providing a new wireless platform for the design of future miniaturized medical implants.
Collapse
Affiliation(s)
- Shitong Mao
- Department of Neurosurgery, University of Pittsburgh, Pittsburgh, PA 15260 USA
- Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA 15260 USA
- School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, 150001, China
| | - Hao Wang
- Department of Neurosurgery, University of Pittsburgh, Pittsburgh, PA 15260 USA
- Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA 15260 USA
| | - Chunbo Zhu
- School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, 150001, China
| | - Zhi-Hong Mao
- Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA 15260 USA
| | - Mingui Sun
- Department of Neurosurgery, University of Pittsburgh, Pittsburgh, PA 15260 USA
- Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA 15260 USA
| |
Collapse
|
17
|
Agarwal K, Jegadeesan R, Guo YX, Thakor NV. Wireless Power Transfer Strategies for Implantable Bioelectronics. IEEE Rev Biomed Eng 2017; 10:136-161. [PMID: 28328511 DOI: 10.1109/rbme.2017.2683520] [Citation(s) in RCA: 85] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Neural implants have emerged over the last decade as highly effective solutions for the treatment of dysfunctions and disorders of the nervous system. These implants establish a direct, often bidirectional, interface to the nervous system, both sensing neural signals and providing therapeutic treatments. As a result of the technological progress and successful clinical demonstrations, completely implantable solutions have become a reality and are now commercially available for the treatment of various functional disorders. Central to this development is the wireless power transfer (WPT) that has enabled implantable medical devices (IMDs) to function for extended durations in mobile subjects. In this review, we present the theory, link design, and challenges, along with their probable solutions for the traditional near-field resonant inductively coupled WPT, capacitively coupled short-ranged WPT, and more recently developed ultrasonic, mid-field, and far-field coupled WPT technologies for implantable applications. A comparison of various power transfer methods based on their power budgets and WPT range follows. Power requirements of specific implants like cochlear, retinal, cortical, and peripheral are also considered and currently available IMD solutions are discussed. Patient's safety concerns with respect to electrical, biological, physical, electromagnetic interference, and cyber security from an implanted neurotech device are also explored in this review. Finally, we discuss and anticipate future developments that will enhance the capabilities of current-day wirelessly powered implants and make them more efficient and integrable with other electronic components in IMDs.
Collapse
|
18
|
A Pulsed Coding Technique Based on Optical UWB Modulation for High Data Rate Low Power Wireless Implantable Biotelemetry. ELECTRONICS 2016. [DOI: 10.3390/electronics5040069] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
19
|
Lin YP, Tang KT. An Inductive Power and Data Telemetry Subsystem With Fast Transient Low Dropout Regulator for Biomedical Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2016; 10:435-444. [PMID: 26285218 DOI: 10.1109/tbcas.2015.2447526] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
This paper presents a capacitorless low-dropout (LDO) regulator with fast transient response and data reverse telemetry circuit for fully implantable wireless transmission applications. We propose a novel hybrid feedback structure using high-frequency compensation technology to achieve a rapid transient response for the LDO regulator. To reduce the size of the implant and transmit neural recordings through the same coil without interfering with power transmission, the load-shift-key (LSK) modulation technique is adopted for back data telemetry. The proposed implantable chip, fabricated using commercial 0.18 μm complementary metal oxide semiconductor technology, yielded an output power of 15 mW. Under 1.15 V operation voltage, the maximum overshoot and undershoot voltages were less than 45 mV and 55 mV, respectively, for a 15 mA full-load current whose rising and falling time were less than 100 ns. The proposed LSK transceiver uses a digitized demodulator to improve bandwidth efficiency for low carrier frequency operation.
Collapse
|
20
|
Nagaraj S, Rassam FG. Improved Noncoherent UWB Receiver for Implantable Biomedical Devices. IEEE Trans Biomed Eng 2016; 63:2220-5. [PMID: 26841381 DOI: 10.1109/tbme.2015.2511538] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
GOAL The purpose of this paper is to describe a novel noncoherent receiver architecture to improve the error performance of impulse-radio ultrawideband (IR-UWB) in bioimplanted devices. IR-UWB receivers based on energy detection are popular in biomedical applications owing to the low implementation cost/complexity and the high data rates that UWB can potentially support. Implanted devices suffer from severe frequency-dependent attenuation due to human blood and tissues, while most receivers in the literature are designed based on commonly used indoor wireless channel models. METHOD We propose a novel receiver design that is based on judiciously combining the energies in different bands of the signal spectrum with a weighted linear combiner. We derive the optimum coefficients of the combiner. RESULTS The receiver retains almost all of the advantages of a conventional noncoherent detector, but can also compensate for attenuation properties of blood/tissue. The receiver design can be adapted to different implantation depths by simply varying the combiner weights. The receiver can also be considered to be a simple form of equalizer for noncoherent reception. Our simulations show about 2-dB improvement over other commonly used receivers. SIGNIFICANCE This receiver design is significant in that it can enhance critical battery life of implanted transmitters.
Collapse
|
21
|
Kiani M, Ghovanloo M. A 13.56-mbps pulse delay modulation based transceiver for simultaneous near-field data and power transmission. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2015; 9:1-11. [PMID: 24760945 DOI: 10.1109/tbcas.2014.2304956] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
A fully-integrated near-field wireless transceiver has been presented for simultaneous data and power transmission across inductive links, which operates based on pulse delay modulation (PDM) technique. PDM is a low-power carrier-less modulation scheme that offers wide bandwidth along with robustness against strong power carrier interference, which makes it suitable for implantable neuroprosthetic devices, such as retinal implants. To transmit each bit, a pattern of narrow pulses are generated at the same frequency of the power carrier across the transmitter (Tx) data coil with specific time delays to initiate decaying ringing across the tuned receiver (Rx) data coil. This ringing shifts the zero-crossing times of the undesired power carrier interference on the Rx data coil, resulting in a phase shift between the signals across Rx power and data coils, from which the data bit stream can be recovered. A PDM transceiver prototype was fabricated in a 0.35- μm standard CMOS process, occupying 1.6 mm(2). The transceiver achieved a measured 13.56 Mbps data rate with a raw bit error rate (BER) of 4.3×10(-7) at 10 mm distance between figure-8 data coils, despite a signal-to-interference ratio (SIR) of -18.5 dB across the Rx data coil. At the same time, a class-D power amplifier, operating at 13.56 MHz, delivered 42 mW of regulated power across a separate pair of high-Q power coils, aligned with the data coils. The PDM data Tx and Rx power consumptions were 960 pJ/bit and 162 pJ/bit, respectively, at 1.8 V supply voltage.
Collapse
|
22
|
Navajas J, Barsakcioglu DY, Eftekhar A, Jackson A, Constandinou TG, Quian Quiroga R. Minimum requirements for accurate and efficient real-time on-chip spike sorting. J Neurosci Methods 2014; 230:51-64. [PMID: 24769170 PMCID: PMC4151286 DOI: 10.1016/j.jneumeth.2014.04.018] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2014] [Revised: 04/11/2014] [Accepted: 04/14/2014] [Indexed: 11/30/2022]
Abstract
BACKGROUND Extracellular recordings are performed by inserting electrodes in the brain, relaying the signals to external power-demanding devices, where spikes are detected and sorted in order to identify the firing activity of different putative neurons. A main caveat of these recordings is the necessity of wires passing through the scalp and skin in order to connect intracortical electrodes to external amplifiers. The aim of this paper is to evaluate the feasibility of an implantable platform (i.e., a chip) with the capability to wirelessly transmit the neural signals and perform real-time on-site spike sorting. NEW METHOD We computationally modelled a two-stage implementation for online, robust, and efficient spike sorting. In the first stage, spikes are detected on-chip and streamed to an external computer where mean templates are created and sent back to the chip. In the second stage, spikes are sorted in real-time through template matching. RESULTS We evaluated this procedure using realistic simulations of extracellular recordings and describe a set of specifications that optimise performance while keeping to a minimum the signal requirements and the complexity of the calculations. COMPARISON WITH EXISTING METHODS A key bottleneck for the development of long-term BMIs is to find an inexpensive method for real-time spike sorting. Here, we simulated a solution to this problem that uses both offline and online processing of the data. CONCLUSIONS Hardware implementations of this method therefore enable low-power long-term wireless transmission of multiple site extracellular recordings, with application to wireless BMIs or closed-loop stimulation designs.
Collapse
Affiliation(s)
- Joaquin Navajas
- Centre for Systems Neuroscience, University of Leicester, 9 Salisbury Road, LE1 7QR, United Kingdom.
| | - Deren Y Barsakcioglu
- Centre for Bio-Inspired Technology, Department of Electrical and Electronic Engineering, Imperial College London, SW7 2AZ, United Kingdom
| | - Amir Eftekhar
- Centre for Bio-Inspired Technology, Department of Electrical and Electronic Engineering, Imperial College London, SW7 2AZ, United Kingdom
| | - Andrew Jackson
- Institute of Neuroscience, Newcastle University, Newcastle-upon-Tyne NE2 4HH, United Kingdom
| | - Timothy G Constandinou
- Centre for Bio-Inspired Technology, Department of Electrical and Electronic Engineering, Imperial College London, SW7 2AZ, United Kingdom
| | - Rodrigo Quian Quiroga
- Centre for Systems Neuroscience, University of Leicester, 9 Salisbury Road, LE1 7QR, United Kingdom
| |
Collapse
|