1
|
Homayounzade M, Homayounzadeh M, Khooban MH. Robust positive control of tumour growth using angiogenic inhibition. IET Syst Biol 2023; 17:288-301. [PMID: 37787083 PMCID: PMC10580019 DOI: 10.1049/syb2.12076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2023] [Revised: 07/26/2023] [Accepted: 09/01/2023] [Indexed: 10/04/2023] Open
Abstract
In practice, many physical systems, including physiological ones, can be considered whose input can take only positive quantities. However, most of the conventional control methods do not support the positivity of the main input data to the system. Furthermore, the parameters of these systems, similar to other non-linear systems, are either not accurately identified or may change over time. Therefore, it is reasonable to design a controller that is robust against system uncertainties. A robust positive-input control method is proposed for the automatic treatment of targeted anti-angiogenic therapy implementing a recently published tumour growth model based on experiments conducted on mouse models. The backstepping (BS) approach is applied to design the positive input controller using sensory data of tumour volume as feedback. Unlike previous studies, the proposed controller only requires the measurement of tumour volume and does not require the measurement of inhibitor level. The exponential stability of the controlled system is proved mathematically using the Lyapunov theorem. As a result, the convergence rate of the tumour volume can be controlled, which is an important issue in cancer treatment. Moreover, the robustness of the system against parametric uncertainties is verified mathematically using the Lyapunov theorem. The real-time simulation results-based (OPAL-RT) and comparisons with previous studies confirm the theoretical findings and effectiveness of the proposed method.
Collapse
|
2
|
Sanz R, García P, Romero-Vivó S, Díez JL, Bondia J. Near-optimal feedback control for postprandial glucose regulation in type 1 diabetes. ISA TRANSACTIONS 2023; 133:345-352. [PMID: 36116963 DOI: 10.1016/j.isatra.2022.06.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 04/19/2022] [Accepted: 06/26/2022] [Indexed: 06/15/2023]
Abstract
This paper is focused on feedback control of postprandial glucose levels for patients with type 1 Diabetes Mellitus. There are two important limitations that make this a challenging problem. First, the slow subcutaneous insulin pharmacokinetics that introduces a significant lag into the control loop. Second, the positivity constraint on the control action, meaning that it is not possible to remove insulin from the body. In this paper, both issues are explicitly considered in the design process using the internal model control framework, to derive a near-optimal feedback controller. Optimality is understood here as minimizing the blood glucose peak after a meal intake and, at the same time, preventing glucose values below a prescribed threshold. It is shown how the proposed controller approaches the optimal closed-loop performance as a limit case. The theoretical results are supported by a numerical example and the feasibility of the overall strategy under uncertainties is illustrated using an extended version UVa/Padova metabolic simulator.
Collapse
Affiliation(s)
- R Sanz
- Instituto de Automática e Informática Industrial, Universitat Politècnica de València, 46022 València, Spain.
| | - P García
- Instituto de Automática e Informática Industrial, Universitat Politècnica de València, 46022 València, Spain.
| | - S Romero-Vivó
- Instituto de Matemática Multidisciplinar, Universitat Politècnica de València, 46022 València, Spain; Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas, Instituto de Salud Carlos III, 28029 Madrid, Spain.
| | - J L Díez
- Instituto de Automática e Informática Industrial, Universitat Politècnica de València, 46022 València, Spain; Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas, Instituto de Salud Carlos III, 28029 Madrid, Spain.
| | - J Bondia
- Instituto de Automática e Informática Industrial, Universitat Politècnica de València, 46022 València, Spain; Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas, Instituto de Salud Carlos III, 28029 Madrid, Spain.
| |
Collapse
|
3
|
Cun JE, Fan X, Pan Q, Gao W, Luo K, He B, Pu Y. Copper-based metal-organic frameworks for biomedical applications. Adv Colloid Interface Sci 2022; 305:102686. [PMID: 35523098 DOI: 10.1016/j.cis.2022.102686] [Citation(s) in RCA: 46] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Revised: 04/22/2022] [Accepted: 04/25/2022] [Indexed: 12/11/2022]
Abstract
Metal-organic frameworks (MOFs) are a class of important porous, crystalline materials composed of metal ions (clusters) and organic ligands. Owing to the unique redox chemistry, photochemical and electrical property, and catalytic activity of Cu2+/+, copper-based MOFs (Cu-MOFs) have been recently and extensively explored in various biomedical fields. In this review, we first make a brief introduction to the synthesis of Cu-MOFs and their composites, and highlight the recent synthetic strategies of two most studied representatives, three-dimensional HKUST-1 and two-dimensional Cu-TCPP. The recent advances of Cu-MOFs in the applications of cancer treatment, bacterial inhibition, biosensing, biocatalysis, and wound healing are summarized and discussed. Furthermore, we propose a prospect of the future development of Cu-MOFs in biomedical fields and beyond.
Collapse
Affiliation(s)
- Ju-E Cun
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu 610064, China
| | - Xi Fan
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu 610064, China
| | - Qingqing Pan
- School of Preclinical Medicine, Chengdu University, Chengdu, China
| | - Wenxia Gao
- College of Chemistry & Materials Engineering, Wenzhou University, Wenzhou 325027, China
| | - Kui Luo
- Huaxi MR Research Center (HMRRC), Department of Radiology, West China Hospital, Functional and molecular imaging Key Laboratory of Sichuan Province, Sichuan University, Chengdu 610041, China
| | - Bin He
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu 610064, China
| | - Yuji Pu
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu 610064, China.
| |
Collapse
|
4
|
SPR-Based Sensor for the Early Detection or Monitoring of Kidney Problems. Int J Biomater 2022; 2022:9135172. [PMID: 35755268 PMCID: PMC9225913 DOI: 10.1155/2022/9135172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 05/12/2022] [Accepted: 05/19/2022] [Indexed: 11/17/2022] Open
Abstract
SPR-based technology has emerged as one of the most versatile optical tools for analyzing the binding mechanism of molecular interaction due to its inherent advantages in sensing applications, such as real-time, label-free, and high sensitivity characteristics. SPR is widely used in various fields, including healthcare, environmental management, and food-borne illness analysis. Meanwhile, kidney disease has grown to be one of the world's most serious public health problems in recent decades, resulting in physical degeneration and even death. As a result, several studies have published their findings regarding developing of reliable sensor technology based on the SPR phenomenon. However, an integrated and comprehensive discussion regarding the application of SPR-based sensors for detecting of kidney disease has not yet been found. Therefore, this review will discuss the recent advancements in the development of SPR-based sensors for monitoring kidney-related diseases. Numerous SPR configurations will be discussed, including Kretschmann, Otto, optical fiber-based SPR, and LSPR, which are all used to detect analytes associated with kidney disease, including urea, creatinine, glucose, uric acid, and dopamine. This review aims to show the broad application of SPR sensors which encouraged the development of SPR sensors for kidney problems monitoring.
Collapse
|
5
|
Rahmanian F, Asemani MH, Dehghani M, Mobayen S. Robust dynamic output feedback control of blood glucose level in diabetic rat with robust descriptor Kalman filter. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2021.103088] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
6
|
High-performance field-effect transistor glucose biosensors based on bimetallic Ni/Cu metal-organic frameworks. Biosens Bioelectron 2021; 171:112736. [DOI: 10.1016/j.bios.2020.112736] [Citation(s) in RCA: 44] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 10/11/2020] [Accepted: 10/14/2020] [Indexed: 01/17/2023]
|
7
|
Batmani Y, Khodakaramzadeh S. Blood glucose concentration control for type 1 diabetic patients: a multiple-model strategy. IET Syst Biol 2020; 14:24-30. [PMID: 31931478 DOI: 10.1049/iet-syb.2018.5049] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
In this study, a multiple-model strategy is evaluated as an alternative closed-loop method for subcutaneous insulin delivery in type 1 diabetes. Non-linearities of the glucose-insulin regulatory system are considered by modelling the system around five different operating points. After conducting some identification experiments in the UVA/Padova metabolic simulator (accepted simulator by the US Food and Drug Administration (FDA)), five transfer functions are obtained for these operating points. Paying attention to some physiological facts, the control objectives such as the required settling time and permissible bounds of overshoots and undershoots are determined for any transfer functions. Then, five PID controllers are tuned to achieve these objectives and a bank of controllers is constructed. To cope with difficulties of the presence of delays in subcutaneous blood glucose (BG) measuring and in administration of insulin, a glucose-dependent setpoint is considered as the desired trajectory for the BG concentration. The performance of the obtained closed-loop glucose-insulin regulatory system is investigated on the in silico adult cohort of the UVA/Padova metabolic simulator. The obtained results show that the proposed multiple-model strategy leads to a closed-loop mechanism with limited hyperglycemia and no severe hypoglycemia.
Collapse
Affiliation(s)
- Yazdan Batmani
- Department of Electrical Engineering, University of Kurdistan, Sanandaj, Iran.
| | | |
Collapse
|
8
|
Zheng W, Han B, E S, Sun Y, Li X, Cai Y, Zhang YN. Highly-sensitive and reflective glucose sensor based on optical fiber surface plasmon resonance. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105010] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
9
|
A systematic stochastic design strategy achieving an optimal tradeoff between peak BGL and probability of hypoglycaemic events for individuals having type 1 diabetes mellitus. Biomed Signal Process Control 2020. [DOI: 10.1016/j.bspc.2019.101813] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
10
|
Moscoso-Vasquez M, Colmegna P, Rosales N, Garelli F, Sanchez-Pena R. Control-Oriented Model With Intra-Patient Variations for an Artificial Pancreas. IEEE J Biomed Health Inform 2020; 24:2681-2689. [PMID: 31995506 DOI: 10.1109/jbhi.2020.2969389] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
In this work, a low-order model designed for glucose regulation in Type 1 Diabetes Mellitus (T1DM) is obtained from the UVA/Padova metabolic simulator. It captures not only the nonlinear behavior of the glucose-insulin system, but also intra-patient variations related to daily insulin sensitivity ( SI) changes. To overcome the large inter-subject variability, the model can also be personalized based on a priori patient information. The structure is amenable for linear parameter varying (LPV) controller design, and represents the dynamics from the subcutaneous insulin input to the subcutaneous glucose output. The efficacy of this model is evaluated in comparison with a previous control-oriented model which in turn is an improvement of previous models. Both models are compared in terms of their open- and closed-loop differences with respect to the UVA/Padova model. The proposed model outperforms previous T1DM control-oriented models, which could potentially lead to more robust and reliable controllers for glycemia regulation.
Collapse
|
11
|
Karsaz A. Chattering -free hybrid adaptive neuro-fuzzy inference system-particle swarm optimisation data fusion-based BG-level control. IET Syst Biol 2020; 14:31-38. [PMID: 31931479 DOI: 10.1049/iet-syb.2018.5019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
In this study, a closed-loop control scheme is proposed for the glucose-insulin regulatory system in type-1 diabetic mellitus (T1DM) patients. Some innovative hybrid glucose-insulin regulators have combined artificial intelligence such as fuzzy logic and genetic algorithm with well known Palumbo model to regulate the blood glucose (BG) level in T1DM patients. However, most of these approaches have focused on the glucose reference tracking, and the qualitative of this tracking such as chattering reduction of insulin injection has not been well-studied. Higher-order sliding mode (HoSM) controllers have been employed to attenuate the effect of chattering. Owing to the delayed nature and non-linear property of glucose-insulin mechanism as well as various unmeasurable disturbances, even the HoSM methods are partly successful. In this study, data fusion of adaptive neuro-fuzzy inference systems optimised by particle swarm optimisation has been presented. The excellent performance of the proposed hybrid controller, i.e. desired BG-level tracking and chattering reduction in the presence of daily glucose-level disturbances is verified.
Collapse
Affiliation(s)
- Ali Karsaz
- Department of Electrical and Electronic Engineering, Khorasan Institute of Higher Education, Mashhad, Iran.
| |
Collapse
|
12
|
Fushimi E, Colmegna P, De Battista H, Garelli F, Sánchez-Peña R. Artificial Pancreas: Evaluating the ARG Algorithm Without Meal Announcement. J Diabetes Sci Technol 2019; 13:1035-1043. [PMID: 31339059 PMCID: PMC6835180 DOI: 10.1177/1932296819864585] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Either under standard basal-bolus treatment or hybrid closed-loop control, subjects with type 1 diabetes are required to count carbohydrates (CHOs). However, CHO counting is not only burdensome but also prone to errors. Recently, an artificial pancreas algorithm that does not require premeal insulin boluses-the so-called automatic regulation of glucose (ARG)-was introduced. In its first pilot clinical study, although the exact CHO counting was not required, subjects still needed to announce the meal time and classify the meal size. METHOD An automatic switching signal generator (SSG) is proposed in this work to remove the manual mealtime announcement from the control strategy. The SSG is based on a Kalman filter and works with continuous glucose monitoring readings only. RESULTS The ARG algorithm with unannounced meals (ARGum) was tested in silico under the effect of different types of mixed meals and intrapatient variability, and contrasted with the ARG algorithm with announced meals (ARGam). Simulations reveal that, for slow-absorbing meals, the time in the euglycemic range, [70-180] mg/dL, increases using the unannounced strategy (ARGam: 78.1 [68.6-80.2]% (median [IQR]) and ARGum: 87.8 [84.5-90.6]%), while similar results were found with fast-absorbing meals (ARGam: 87.4 [86.0-88.9]% and ARGum: 87.6 [86.1-88.8]%). On the other hand, when intrapatient variability is considered, time in euglycemia is also comparable (ARGam: 81.4 [75.4-83.5]% and ARGum: 80.9 [77.0-85.1]%). CONCLUSION In silico results indicate that it is feasible to perform an in vivo evaluation of the ARG algorithm with unannounced meals.
Collapse
Affiliation(s)
- Emilia Fushimi
- Grupo de Control Aplicado (GCA), Instituto LEICI (UNLP-CONICET), Facultad de Ingeniería, Universidad Nacional de La Plata (UNLP), Argentina
- Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET) Argentina
- Emilia Fushimi. Instituto LEICI (Grupo de Control Aplicado), Depto. Electrotecnia, Facultad de Ingeniería, Universidad Nacional de La Plata (UNLP),, Calle 48 y116, La Plata 1900, Argentina.
| | - Patricio Colmegna
- Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET) Argentina
- University of Virginia (UVA), Center for Diabetes Technology, Charlottesville, VA, USA
- Universidad Nacional de Quilmes (UNQ), Argentina
| | - Hernán De Battista
- Grupo de Control Aplicado (GCA), Instituto LEICI (UNLP-CONICET), Facultad de Ingeniería, Universidad Nacional de La Plata (UNLP), Argentina
- Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET) Argentina
| | - Fabricio Garelli
- Grupo de Control Aplicado (GCA), Instituto LEICI (UNLP-CONICET), Facultad de Ingeniería, Universidad Nacional de La Plata (UNLP), Argentina
- Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET) Argentina
| | - Ricardo Sánchez-Peña
- Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET) Argentina
- Universidad Nacional de Quilmes (UNQ), Argentina
| |
Collapse
|
13
|
Farahmand B, Dehghani M, Vafamand N. Fuzzy model-based controller for blood glucose control in type 1 diabetes: An LMI approach. Biomed Signal Process Control 2019. [DOI: 10.1016/j.bspc.2019.101627] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
14
|
Sánchez-Peña R, Colmegna P, Garelli F, De Battista H, García-Violini D, Moscoso-Vásquez M, Rosales N, Fushimi E, Campos-Náñez E, Breton M, Beruto V, Scibona P, Rodriguez C, Giunta J, Simonovich V, Belloso WH, Cherñavvsky D, Grosembacher L. Artificial Pancreas: Clinical Study in Latin America Without Premeal Insulin Boluses. J Diabetes Sci Technol 2018; 12:914-925. [PMID: 29998754 PMCID: PMC6134619 DOI: 10.1177/1932296818786488] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
BACKGROUND Emerging therapies such as closed-loop (CL) glucose control, also known as artificial pancreas (AP) systems, have shown significant improvement in type 1 diabetes mellitus (T1DM) management. However, demanding patient intervention is still required, particularly at meal times. To reduce treatment burden, the automatic regulation of glucose (ARG) algorithm mitigates postprandial glucose excursions without feedforward insulin boluses. This work assesses feasibility of this new strategy in a clinical trial. METHODS A 36-hour pilot study was performed on five T1DM subjects to validate the ARG algorithm. Subjects wore a subcutaneous continuous glucose monitor (CGM) and an insulin pump. Insulin delivery was solely commanded by the ARG algorithm, without premeal insulin boluses. This was the first clinical trial in Latin America to validate an AP controller. RESULTS For the total 36-hour period, results were as follows: average time of CGM readings in range 70-250 mg/dl: 88.6%, in range 70-180 mg/dl: 74.7%, <70 mg/dl: 5.8%, and <50 mg/dl: 0.8%. Results improved analyzing the final 15-hour period of this trial. In that case, the time spent in range was 70-250 mg/dl: 94.7%, in range 70-180 mg/dl: 82.6%, <70 mg/dl: 4.1%, and <50 mg/dl: 0.2%. During the last night the time spent in range was 70-250 mg/dl: 95%, in range 70-180 mg/dl: 87.7%, <70 mg/dl: 5.0%, and <50 mg/dl: 0.0%. No severe hypoglycemia occurred. No serious adverse events were reported. CONCLUSIONS The ARG algorithm was successfully validated in a pilot clinical trial, encouraging further tests with a larger number of patients and in outpatient settings.
Collapse
Affiliation(s)
- Ricardo Sánchez-Peña
- Instituto Tecnológico de Buenos Aires, Buenos Aires, Argentina
- National Scientific and Technical Research Council, Buenos Aires, Argentina
- Ricardo Sánchez-Peña, PhD, National Scientific and Technical Research Council (CONICET), Instituto Tecnológico de Buenos Aires (ITBA), Av Madero 399, Buenos Aires, C1106ACD, Argentina.
| | - Patricio Colmegna
- National Scientific and Technical Research Council, Buenos Aires, Argentina
- University of Virginia, Charlottesville, VA, USA
- Universidad Nacional de Quilmes, Bernal, Buenos Aires, Argentina
| | - Fabricio Garelli
- National Scientific and Technical Research Council, Buenos Aires, Argentina
- Universidad Nacional de La Plata, La Plata, Buenos Aires Argentina
| | - Hernán De Battista
- National Scientific and Technical Research Council, Buenos Aires, Argentina
- Universidad Nacional de La Plata, La Plata, Buenos Aires Argentina
| | - Demián García-Violini
- Instituto Tecnológico de Buenos Aires, Buenos Aires, Argentina
- National Scientific and Technical Research Council, Buenos Aires, Argentina
| | - Marcela Moscoso-Vásquez
- Instituto Tecnológico de Buenos Aires, Buenos Aires, Argentina
- National Scientific and Technical Research Council, Buenos Aires, Argentina
| | - Nicolás Rosales
- Universidad Nacional de La Plata, La Plata, Buenos Aires Argentina
| | - Emilia Fushimi
- National Scientific and Technical Research Council, Buenos Aires, Argentina
- Universidad Nacional de La Plata, La Plata, Buenos Aires Argentina
| | | | - Marc Breton
- University of Virginia, Charlottesville, VA, USA
| | - Valeria Beruto
- Hospital Italiano de Buenos Aires, Buenos Aires, Argentina
| | - Paula Scibona
- Hospital Italiano de Buenos Aires, Buenos Aires, Argentina
| | | | - Javier Giunta
- Hospital Italiano de Buenos Aires, Buenos Aires, Argentina
| | | | | | | | | |
Collapse
|
15
|
Shi D, Dassau E, Doyle FJ. Adaptive Zone Model Predictive Control of Artificial Pancreas Based on Glucose- and Velocity-Dependent Control Penalties. IEEE Trans Biomed Eng 2018; 66:1045-1054. [PMID: 30142748 DOI: 10.1109/tbme.2018.2866392] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
OBJECTIVE Zone model predictive control (MPC) has been proven to be an efficient approach to closed-loop insulin delivery in clinical studies. In this paper, we aim to safely reduce mean glucose levels by proposing control penalty adaptation in the cost function of zone MPC. METHODS A zone MPC method with a dynamic cost function that updates its control penalty parameters in real time according to the predicted glucose and its rate of change is developed. The proposed method is evaluated on the entire 100-adult cohort of the FDA-accepted UVA/Padova T1DM simulator and compared with the zone MPC tested in an extended outpatient study. RESULTS For unannounced meals, the proposed method leads to statistically significant improvements in terms of mean glucose (153.8 mg/dL vs. 159.0 mg/dL; ) and percentage time in [70, 180] mg/dL ([Formula: see text] vs. [Formula: see text]; ) without increasing the risk of hypoglycemia. Performance for announced meals is similar to that obtained without adaptation. The proposed method also behaves properly and safely for scenarios of moderate meal-bolus and basal rate mismatches, as well as simulated unannounced exercise. Advisory-mode analysis based on clinical data indicates that the method can reduce glucose levels through suggesting additional safe amounts of insulin on top of those suggested by the zone MPC used in the study. CONCLUSION The proposed method leads to improved glucose control without increasing hypoglycemia risks. SIGNIFICANCE The results validate the feasibility of improving glucose regulation through glucose- and velocity-dependent control penalty adaptation in MPC design.
Collapse
|
16
|
Gondhalekar R, Dassau E, Doyle FJ. Velocity-weighting & velocity-penalty MPC of an artificial pancreas: Improved safety & performance. AUTOMATICA : THE JOURNAL OF IFAC, THE INTERNATIONAL FEDERATION OF AUTOMATIC CONTROL 2018; 91:105-117. [PMID: 30034017 PMCID: PMC6051553 DOI: 10.1016/j.automatica.2018.01.025] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
A novel Model Predictive Control (MPC) law for the closed-loop operation of an Artificial Pancreas (AP) to treat type 1 diabetes is proposed. The contribution of this paper is to simultaneously enhance both the safety and performance of an AP, by reducing the incidence of controller-induced hypoglycemia, and by promoting assertive hyperglycemia correction. This is achieved by integrating two MPC features separately introduced by the authors previously to independently improve the control performance with respect to these two coupled issues. Velocity-weighting MPC reduces the occurrence of controller-induced hypoglycemia. Velocity-penalty MPC yields more effective hyperglycemia correction. Benefits of the proposed MPC law over the MPC strategy deployed in the authors' previous clinical trial campaign are demonstrated via a comprehensive in-silico analysis. The proposed MPC law was deployed in four distinct US Food & Drug Administration approved clinical trial campaigns, the most extensive of which involved 29 subjects each spending three months in closed-loop. The paper includes implementation details, an explanation of the state-dependent cost functions required for velocity-weighting and penalties, a discussion of the resulting nonlinear optimization problem, a description of the four clinical trial campaigns, and control-related trial highlights.
Collapse
Affiliation(s)
- Ravi Gondhalekar
- Harvard John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Eyal Dassau
- Harvard John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Francis J Doyle
- Harvard John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA, USA
| |
Collapse
|
17
|
Colmegna P, Sánchez-Peña R, Gondhalekar R. Linear parameter-varying model to design control laws for an artificial pancreas. Biomed Signal Process Control 2018. [DOI: 10.1016/j.bspc.2017.09.021] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
18
|
Soylu S, Danisman K. In silico testing of optimized Fuzzy P+D controller for artificial pancreas. Biocybern Biomed Eng 2018. [DOI: 10.1016/j.bbe.2018.02.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
19
|
Gondhalekar R, Dassau E, Doyle FJ. Periodic zone-MPC with asymmetric costs for outpatient-ready safety of an artificial pancreas to treat type 1 diabetes . AUTOMATICA : THE JOURNAL OF IFAC, THE INTERNATIONAL FEDERATION OF AUTOMATIC CONTROL 2016; 71:237-246. [PMID: 27695131 PMCID: PMC5040369 DOI: 10.1016/j.automatica.2016.04.015] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
A novel Model Predictive Control (MPC) law for an Artificial Pancreas (AP) to automatically deliver insulin to people with type 1 diabetes is proposed. The MPC law is an enhancement of the authors' zone-MPC approach that has successfully been trialled in-clinic, and targets the safe outpatient deployment of an AP. The MPC law controls blood-glucose levels to a diurnally time-dependent zone, and enforces diurnal, hard input constraints. The main algorithmic novelty is the use of asymmetric input costs in the MPC problem's objective function. This improves safety by facilitating the independent design of the controller's responses to hyperglycemia and hypoglycemia. The proposed controller performs predictive pump-suspension in the face of impending hypoglycemia, and subsequent predictive pump-resumption, based only on clinical needs and feedback. The proposed MPC strategy's benefits are demonstrated by in-silico studies as well as highlights from a US Food and Drug Administration approved clinical trial in which 32 subjects each completed two 25 hour closed-loop sessions employing the proposed MPC law.
Collapse
Affiliation(s)
- Ravi Gondhalekar
- Harvard John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA 02138, USA
| | - Eyal Dassau
- Harvard John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA 02138, USA
| | - Francis J. Doyle
- Harvard John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA 02138, USA
| |
Collapse
|
20
|
Colmegna PH, Sánchez-Peña RS, Gondhalekar R, Dassau E, Doyle FJ. Reducing Glucose Variability Due to Meals and Postprandial Exercise in T1DM Using Switched LPV Control: In Silico Studies. J Diabetes Sci Technol 2016; 10:744-53. [PMID: 27022097 PMCID: PMC5038547 DOI: 10.1177/1932296816638857] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Time-varying dynamics is one of the main issues for achieving safe blood glucose control in type 1 diabetes mellitus (T1DM) patients. In addition, the typical disturbances considered for controller design are meals, which increase the glucose level, and physical activity (PA), which increases the subject's sensitivity to insulin. In previous works the authors have applied a linear parameter-varying (LPV) control technique to manage unannounced meals. METHODS A switched LPV controller that switches between 3 LPV controllers, each with a different level of aggressiveness, is designed to further cope with both unannounced meals and postprandial PA. Thus, the proposed control strategy has a "standard" mode, an "aggressive" mode, and a "conservative" mode. The "standard" mode is designed to be applied most of the time, while the "aggressive" mode is designed to deal only with hyperglycemia situations. On the other hand, the "conservative" mode is focused on postprandial PA control. RESULTS An ad hoc simulator has been developed to test the proposed controller. This simulator is based on the distribution version of the UVA/Padova model and includes the effect of PA based on Schiavon.(1) The test results obtained when using this simulator indicate that the proposed control law substantially reduces the risk of hypoglycemia with the conservative strategy, while the risk of hyperglycemia is scarcely affected. CONCLUSIONS It is demonstrated that the announcement, or anticipation, of exercise is indispensable for letting a mono-hormonal artificial pancreas deal with the consequences of postprandial PA. In view of this the proposed controller allows switching into a conservative mode when notified of PA by the user.
Collapse
Affiliation(s)
- Patricio H Colmegna
- National Scientific and Technical Research Council, Buenos Aires, Argentina Departamento de Ciencia y Tecnología, Universidad Nacional de Quilmes, Buenos Aires, Argentina
| | - Ricardo S Sánchez-Peña
- National Scientific and Technical Research Council, Buenos Aires, Argentina Centro de Sistemas y Control, Instituto Tecnológico de Buenos Aires, Buenos Aires, Argentina
| | - Ravi Gondhalekar
- Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA, USA
| | - Eyal Dassau
- John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Francis J Doyle
- John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA, USA
| |
Collapse
|