1
|
Sun C, Liang Y, Yang X, Zhao B, Zhang P, Liu S, Yang D, Wu T, Zhang J, Guo H. Optimizing biomagnetic sensor performance through in silico diagnostics: A novel approach with BEST (Biomagnetism Evaluation via Simulated Testing). iScience 2024; 27:110167. [PMID: 38974973 PMCID: PMC11226959 DOI: 10.1016/j.isci.2024.110167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 04/28/2024] [Accepted: 05/29/2024] [Indexed: 07/09/2024] Open
Abstract
Advancing biomagnetic measurement capabilities requires a nuanced understanding of sensor performance beyond traditional metrics. This study introduces Biomagnetism Evaluation via Simulated Testing (BEST), a novel methodology combining a current dipole model simulating cardiac biomagnetic fields with a convolutional neural network. Our investigation reveals that optimal sensor array performance is achieved when sensors are in close proximity to the magnetic source, with a shorter effective domain. Contrary to common assumptions, the bottom edge length of the sensor has a negligible impact on array performance. BEST provides a versatile framework for exploring the influence of diverse technical indicators on biomagnetic sensor performance, offering valuable insights for sensor development and selection.
Collapse
Affiliation(s)
- Chenxi Sun
- State Key Laboratory of Advanced Optical Communication Systems and Networks, School of Electronics, and Center for Quantum Information Technology, Peking University, Beijing 100871, China
| | - Yike Liang
- School of Life Sciences, Peking University, Beijing 100871, China
| | - Xiao Yang
- State Key Laboratory of Advanced Optical Communication Systems and Networks, School of Electronics, and Center for Quantum Information Technology, Peking University, Beijing 100871, China
| | - Biying Zhao
- State Key Laboratory of Advanced Optical Communication Systems and Networks, School of Electronics, and Center for Quantum Information Technology, Peking University, Beijing 100871, China
| | - Pengju Zhang
- Faculty of Engineering, University of Bristol, Bristol BS8 1TR, UK
| | - Sirui Liu
- School of Physics, Peking University, Beijing 100871, China
| | - Dongyi Yang
- School of Physics, Peking University, Beijing 100871, China
| | - Teng Wu
- State Key Laboratory of Advanced Optical Communication Systems and Networks, School of Electronics, and Center for Quantum Information Technology, Peking University, Beijing 100871, China
| | - Jianwei Zhang
- School of Physics, Peking University, Beijing 100871, China
| | - Hong Guo
- State Key Laboratory of Advanced Optical Communication Systems and Networks, School of Electronics, and Center for Quantum Information Technology, Peking University, Beijing 100871, China
| |
Collapse
|
2
|
Miljković N, Milenić N, Popović NB, Sodnik J. Data augmentation for generating synthetic electrogastrogram time series. Med Biol Eng Comput 2024:10.1007/s11517-024-03112-0. [PMID: 38705957 DOI: 10.1007/s11517-024-03112-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Accepted: 04/25/2024] [Indexed: 05/07/2024]
Abstract
To address an emerging need for large number of diverse datasets for rigor evaluation of signal processing techniques, we developed and evaluated a new method for generating synthetic electrogastrogram time series. We used electrogastrography (EGG) data from an open database to set model parameters and statistical tests to evaluate synthesized data. Additionally, we illustrated method customization for generating artificial EGG time series alterations caused by the simulator sickness. Proposed data augmentation method generates synthetic EGG data with specified duration, sampling frequency, recording state (postprandial or fasting state), overall noise and breathing artifact injection, and pauses in the gastric rhythm (arrhythmia occurrence) with statistically significant difference between postprandial and fasting states in > 70% cases while not accounting for individual differences. Features obtained from the synthetic EGG signal resembling simulator sickness occurrence displayed expected trends. The code for generation of synthetic EGG time series is not only freely available and can be further customized to assess signal processing algorithms but also may be used to increase data diversity for training artificial intelligence (AI) algorithms. The proposed approach is customized for EGG data synthesis but can be easily utilized for other biosignals with similar nature such as electroencephalogram.
Collapse
Affiliation(s)
- Nadica Miljković
- University of Belgrade-School of Electrical Engineering, Bulevar Kralja Aleksandra 73, 11000, Belgrade, Serbia.
- Faculty of Electrical Engineering, University of Ljubljana, Tržaška Cesta 25, 1000, Ljubljana, Slovenia.
| | - Nikola Milenić
- University of Belgrade-School of Electrical Engineering, Bulevar Kralja Aleksandra 73, 11000, Belgrade, Serbia
| | - Nenad B Popović
- University of Belgrade-School of Electrical Engineering, Bulevar Kralja Aleksandra 73, 11000, Belgrade, Serbia
| | - Jaka Sodnik
- Faculty of Electrical Engineering, University of Ljubljana, Tržaška Cesta 25, 1000, Ljubljana, Slovenia
| |
Collapse
|
3
|
Witczyńska A, Alaburda A, Grześk G, Nowaczyk J, Nowaczyk A. Unveiling the Multifaceted Problems Associated with Dysrhythmia. Int J Mol Sci 2023; 25:263. [PMID: 38203440 PMCID: PMC10778936 DOI: 10.3390/ijms25010263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 12/15/2023] [Accepted: 12/21/2023] [Indexed: 01/12/2024] Open
Abstract
Dysrhythmia is a term referring to the occurrence of spontaneous and repetitive changes in potentials with parameters deviating from those considered normal. The term refers to heart anomalies but has a broader meaning. Dysrhythmias may concern the heart, neurological system, digestive system, and sensory organs. Ion currents conducted through ion channels are a universal phenomenon. The occurrence of channel abnormalities will therefore result in disorders with clinical manifestations depending on the affected tissue, but phenomena from other tissues and organs may also manifest themselves. A similar problem concerns the implementation of pharmacotherapy, the mechanism of which is related to the impact on various ion currents. Treatment in this case may cause unfavorable effects on other tissues and organs. Drugs acting through the modulation of ion currents are characterized by relatively low tissue specificity. To assess a therapy's efficacy and safety, the risk of occurrences in other tissues with similar mechanisms of action must be considered. In the present review, the focus is shifted prominently onto a comparison of abnormal electrical activity within different tissues and organs. This review includes an overview of the types of dysrhythmias and the basic techniques of clinical examination of electrophysiological disorders. It also presents a concise overview of the available pharmacotherapy in particular diseases. In addition, the authors review the relevant ion channels and their research technique based on patch clumping.
Collapse
Affiliation(s)
- Adrianna Witczyńska
- Department of Organic Chemistry, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University, 87-100 Toruń, Poland;
| | - Aidas Alaburda
- Department of Neurobiology and Biophysics, Institute of Bioscience, Vilnius University Saulėtekio Ave. 7, LT-10257 Vilnius, Lithuania;
| | - Grzegorz Grześk
- Department of Cardiology and Clinical Pharmacology, Faculty of Health Sciences, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University, 87-100 Toruń, Poland;
| | - Jacek Nowaczyk
- Department of Physical Chemistry and Physicochemistry of Polymers, Faculty of Chemistry, Nicolaus Copernicus University, 7 Gagarina St., 87-100 Toruń, Poland;
| | - Alicja Nowaczyk
- Department of Organic Chemistry, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University, 87-100 Toruń, Poland;
| |
Collapse
|
4
|
O'Grady G, Varghese C, Schamberg G, Calder S, Du P, Xu W, Tack J, Daker C, Mousa H, Abell TL, Parkman HP, Ho V, Bradshaw LA, Hobson A, Andrews CN, Gharibans AA. Principles and clinical methods of body surface gastric mapping: Technical review. Neurogastroenterol Motil 2023; 35:e14556. [PMID: 36989183 PMCID: PMC10524901 DOI: 10.1111/nmo.14556] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 01/29/2023] [Accepted: 02/12/2023] [Indexed: 03/30/2023]
Abstract
BACKGROUND AND PURPOSE Chronic gastric symptoms are common, however differentiating specific contributing mechanisms in individual patients remains challenging. Abnormal gastric motility is present in a significant subgroup, but reliable methods for assessing gastric motor function in clinical practice are lacking. Body surface gastric mapping (BSGM) is a new diagnostic aid, employs multi-electrode arrays to measure and map gastric myoelectrical activity non-invasively in high resolution. Clinical adoption of BSGM is currently expanding following studies demonstrating the ability to achieve specific patient subgrouping, and subsequent regulatory clearances. An international working group was formed in order to standardize clinical BSGM methods, encompassing a technical group developing BSGM methods and a clinical advisory group. The working group performed a technical literature review and synthesis focusing on the rationale, principles, methods, and clinical applications of BSGM, with secondary review by the clinical group. The principles and validation of BSGM were evaluated, including key advances achieved over legacy electrogastrography (EGG). Methods for BSGM were reviewed, including device design considerations, patient preparation, test conduct, and data processing steps. Recent advances in BSGM test metrics and reference intervals are discussed, including four novel metrics, being the 'principal gastric frequency', BMI-adjusted amplitude, Gastric Alimetry Rhythm Index™, and fed: fasted amplitude ratio. An additional essential element of BSGM has been the introduction of validated digital tools for standardized symptom profiling, performed simultaneously during testing. Specific phenotypes identifiable by BSGM and the associated symptom profiles were codified with reference to pathophysiology. Finally, knowledge gaps and priority areas for future BSGM research were also identified by the working group.
Collapse
Affiliation(s)
- Gregory O'Grady
- Department of Surgery, The University of Auckland, Auckland, New Zealand
- Alimetry Ltd, Auckland, New Zealand
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Chris Varghese
- Department of Surgery, The University of Auckland, Auckland, New Zealand
| | - Gabriel Schamberg
- Department of Surgery, The University of Auckland, Auckland, New Zealand
- Alimetry Ltd, Auckland, New Zealand
| | | | - Peng Du
- Alimetry Ltd, Auckland, New Zealand
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - William Xu
- Department of Surgery, The University of Auckland, Auckland, New Zealand
| | - Jan Tack
- Department of Gastroenterology, University Hospitals, Leuven, Belgium
| | | | - Hayat Mousa
- Division of Gastroenterology, Lustgarten Motility Center, The Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | - Thomas L Abell
- Division of Gastroenterology, Hepatology and Nutrition, University of Louisville, Louisville, Kentucky, USA
| | - Henry P Parkman
- Department of Medicine, Temple University Hospital, Philadelphia, Pennsylvania, USA
| | - Vincent Ho
- Western Sydney University, Sydney, New South Wales, Australia
| | | | | | - Christopher N Andrews
- Division of Gastroenterology and Hepatology, University of Calgary, Calgary, Alberta, Canada
| | - Armen A Gharibans
- Department of Surgery, The University of Auckland, Auckland, New Zealand
- Alimetry Ltd, Auckland, New Zealand
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| |
Collapse
|
5
|
Schamberg G, Calder S, Varghese C, Xu W, Wang WJ, Ho V, Daker C, Andrews CN, O'Grady G, Gharibans AA. Comparison of Gastric Alimetry ® body surface gastric mapping versus electrogastrography spectral analysis. Sci Rep 2023; 13:14987. [PMID: 37696955 PMCID: PMC10495352 DOI: 10.1038/s41598-023-41645-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Accepted: 08/29/2023] [Indexed: 09/13/2023] Open
Abstract
Electrogastrography (EGG) non-invasively evaluates gastric motility but is viewed as lacking clinical utility. Gastric Alimetry® is a new diagnostic test that combines high-resolution body surface gastric mapping (BSGM) with validated symptom profiling, with the goal of overcoming EGG's limitations. This study directly compared EGG and BSGM to define performance differences in spectral analysis. Comparisons between Gastric Alimetry BSGM and EGG were conducted by protocolized retrospective evaluation of 178 subjects [110 controls; 68 nausea and vomiting (NVS) and/or type 1 diabetes (T1D)]. Comparisons followed standard methodologies for each test (pre-processing, post-processing, analysis), with statistical evaluations for group-level differences, symptom correlations, and patient-level classifications. BSGM showed substantially tighter frequency ranges vs EGG in controls. Both tests detected rhythm instability in NVS, but EGG showed opposite frequency effects in T1D. BSGM showed an 8× increase in the number of significant correlations with symptoms. BSGM accuracy for patient-level classification was 0.78 for patients vs controls and 0.96 as compared to blinded consensus panel; EGG accuracy was 0.54 and 0.43. EGG detected group-level differences in patients, but lacked symptom correlations and showed poor accuracy for patient-level classification, explaining EGG's limited clinical utility. BSGM demonstrated substantial performance improvements across all domains.
Collapse
Affiliation(s)
- Gabriel Schamberg
- Department of Surgery, The University of Auckland, Auckland, New Zealand
- Alimetry Ltd, Auckland, New Zealand
| | - Stefan Calder
- Department of Surgery, The University of Auckland, Auckland, New Zealand
- Alimetry Ltd, Auckland, New Zealand
| | - Chris Varghese
- Department of Surgery, The University of Auckland, Auckland, New Zealand
| | - William Xu
- Department of Surgery, The University of Auckland, Auckland, New Zealand
| | - William Jiaen Wang
- School of Medicine, Western Sydney University, Sydney, Australia
- Department of Gastroenterology and Hepatology, Campbelltown Hospital, Sydney, Australia
- Department of Gastroenterology and Hepatology, Townsville University Hospital, Townsville, Australia
- Department of Gastroenterology and Hepatology, Princess Alexandra Hospital, Brisbane, Australia
| | - Vincent Ho
- School of Medicine, Western Sydney University, Sydney, Australia
- Department of Gastroenterology and Hepatology, Campbelltown Hospital, Sydney, Australia
| | - Charlotte Daker
- Department of Gastroenterology, North Shore Hospital, Auckland, New Zealand
| | | | - Greg O'Grady
- Department of Surgery, The University of Auckland, Auckland, New Zealand
- Alimetry Ltd, Auckland, New Zealand
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Armen A Gharibans
- Department of Surgery, The University of Auckland, Auckland, New Zealand.
- Alimetry Ltd, Auckland, New Zealand.
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand.
- Perelman School of Medicine, University of Pennsylvania, Pennsylvania, United States.
| |
Collapse
|
6
|
Ji S, Li B, Zhu C, Jiang G, Tang Y, Chen L. Risk assessment model for sleep disturbance based on gastrointestinal myoelectrical activity in middle-aged and elderly people. Front Psychiatry 2023; 14:1183108. [PMID: 37426096 PMCID: PMC10327604 DOI: 10.3389/fpsyt.2023.1183108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Accepted: 06/05/2023] [Indexed: 07/11/2023] Open
Abstract
Background Sleep disturbance has become a considerable factor affecting the quality of life for middle-aged and elderly people; however, there are still many obstacles to screening sleep disturbance for those people. Given the growing awareness of the association between gastrointestinal function and sleep disturbance, our study aims to predict the risk of sleep disturbance using gastrointestinal electrophysiological signals. Methods The Pittsburgh Sleep Quality Index and gastrointestinal electrophysiological signals of 914 participants in western China were used to establish the model. Demographic characteristics and routine blood test were collected as covariates. Participants were randomly assigned into two sets with a 7:3 ratio for training and validation. In the training set, the least absolute shrinkage and selection operator (LASSO) regression and stepwise logistic regression were used, respectively for variables selection and optimization. To assess the model performance, receiver operator characteristic (ROC) curve, calibration curve and decision curve analysis (DCA) were utilized. Then, validation was performed. Results Thirteen predictors were chosen from 46 variables by LASSO regression. Then, age, gender, percentage of normal slow wave and electrical spreading rate on the pre-meal gastric channel, dominant power ratio on the post-meal gastric channel, coupling percent and dominant frequency on the post-meal intestinal channel were the seven predictors reserved by logistic regression. The area under ROC curve was 0.65 in the training set and 0.63 in the validation set, both exhibited moderate predictive ability. Furthermore, by overlapping the DCA results of two data-sets, there might be clinical net benefit if 0.35 was used as reference threshold for high risk of sleep disturbance. Conclusion The model performs a worthy predictive potency for sleep disturbance, which not only provides clinical evidence for the association of gastrointestinal function with sleep disturbance, but also can be considered as an auxiliary assessment for screening sleep disturbance.
Collapse
Affiliation(s)
- Shuming Ji
- Department of Clinical Research Management, West China Hospital, Sichuan University, Chengdu, China
| | - Baichuan Li
- Department of Neurology, Joint Research Institution of Altitude Health, West China Hospital, Sichuan University, Chengdu, China
| | - Chenxing Zhu
- Department of Clinical Research Management, West China Hospital, Sichuan University, Chengdu, China
| | - Guohui Jiang
- Department of Neurology, Affiliated Hospital of North Sichuan Medical College, Nanchong, Sichuan, China
| | - Yusha Tang
- Department of Neurology, Joint Research Institution of Altitude Health, West China Hospital, Sichuan University, Chengdu, China
| | - Lei Chen
- Department of Neurology, Joint Research Institution of Altitude Health, West China Hospital, Sichuan University, Chengdu, China
| |
Collapse
|
7
|
Gharibans AA, Hayes TCL, Carson DA, Calder S, Varghese C, Du P, Yarmut Y, Waite S, Keane C, Woodhead JST, Andrews CN, O'Grady G. A novel scalable electrode array and system for non-invasively assessing gastric function using flexible electronics. Neurogastroenterol Motil 2023; 35:e14418. [PMID: 35699340 PMCID: PMC10078595 DOI: 10.1111/nmo.14418] [Citation(s) in RCA: 20] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 03/29/2022] [Accepted: 05/05/2022] [Indexed: 02/02/2023]
Abstract
BACKGROUND Disorders of gastric function are highly prevalent, but diagnosis often remains symptom-based and inconclusive. Body surface gastric mapping is an emerging diagnostic solution, but current approaches lack scalability and are cumbersome and clinically impractical. We present a novel scalable system for non-invasively mapping gastric electrophysiology in high-resolution (HR) at the body surface. METHODS The system comprises a custom-designed stretchable high-resolution "peel-and-stick" sensor array (8 × 8 pre-gelled Ag/AgCl electrodes at 2 cm spacing; area 225 cm2 ), wearable data logger with custom electronics incorporating bioamplifier chips, accelerometer and Bluetooth synchronized in real-time to an App with cloud connectivity. Automated algorithms filter and extract HR biomarkers including propagation (phase) mapping. The system was tested in a cohort of 24 healthy subjects to define reliability and characterize features of normal gastric activity (30 m fasting, standardized meal, and 4 h postprandial). KEY RESULTS Gastric mapping was successfully achieved non-invasively in all cases (16 male; 8 female; aged 20-73 years; BMI 24.2 ± 3.5). In all subjects, gastric electrophysiology and meal responses were successfully captured and quantified non-invasively (mean frequency 2.9 ± 0.3 cycles per minute; peak amplitude at mean 60 m postprandially with return to baseline in <4 h). Spatiotemporal mapping showed regular and consistent wave activity of mean direction 182.7° ± 73 (74.7% antegrade, 7.8% retrograde, 17.5% indeterminate). CONCLUSIONS AND INFERENCES BSGM is a new diagnostic tool for assessing gastric function that is scalable and ready for clinical applications, offering several biomarkers that are improved or new to gastroenterology practice.
Collapse
Affiliation(s)
- Armen A Gharibans
- Department of Surgery, University of Auckland, Auckland, New Zealand.,Alimetry Ltd, Auckland, New Zealand.,Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Tommy C L Hayes
- Department of Surgery, University of Auckland, Auckland, New Zealand
| | - Daniel A Carson
- Department of Surgery, University of Auckland, Auckland, New Zealand
| | | | - Chris Varghese
- Department of Surgery, University of Auckland, Auckland, New Zealand
| | - Peng Du
- Alimetry Ltd, Auckland, New Zealand.,Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | | | | | - Celia Keane
- Department of Surgery, University of Auckland, Auckland, New Zealand.,Alimetry Ltd, Auckland, New Zealand
| | - Jonathan S T Woodhead
- Alimetry Ltd, Auckland, New Zealand.,Maurice Wilkins Centre for Molecular Biodiscovery, The University of Auckland, Auckland, New Zealand
| | - Christopher N Andrews
- Alimetry Ltd, Auckland, New Zealand.,Department of Medicine, University of Calgary, NB Calgary, Alberta, Canada
| | - Greg O'Grady
- Department of Surgery, University of Auckland, Auckland, New Zealand.,Alimetry Ltd, Auckland, New Zealand
| |
Collapse
|
8
|
Calder S, Cheng LK, Andrews CN, Paskaranandavadivel N, Waite S, Alighaleh S, Erickson JC, Gharibans A, O'Grady G, Du P. Validation of noninvasive body-surface gastric mapping for detecting gastric slow-wave spatiotemporal features by simultaneous serosal mapping in porcine. Am J Physiol Gastrointest Liver Physiol 2022; 323:G295-G305. [PMID: 35916432 DOI: 10.1152/ajpgi.00049.2022] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Gastric disorders are increasingly prevalent, but reliable noninvasive tools to objectively assess gastric function are lacking. Body-surface gastric mapping (BSGM) is a noninvasive method for the detection of gastric electrophysiological features, which are correlated with symptoms in patients with gastroparesis and functional dyspepsia. Previous studies have validated the relationship between serosal and cutaneous recordings from limited number of channels. This study aimed to comprehensively evaluate the basis of BSGM from 64 cutaneous channels and reliably identify spatial biomarkers associated with slow-wave dysrhythmias. High-resolution electrode arrays were placed to simultaneously capture slow waves from the gastric serosa (32 × 6 electrodes at 4 mm spacing) and epigastrium (8 × 8 electrodes at 20 mm spacing) in 14 porcine subjects. BSGM signals were processed based on a combination of wavelet and phase information analyses. A total of 1,185 individual cycles of slow waves were assessed, out of which 897 (76%) were classified as normal antegrade waves, occurring in 10 (71%) subjects studied. BSGM accurately detected the underlying slow wave in terms of frequency (r = 0.99, P = 0.43) as well as the direction of propagation (P = 0.41, F-measure: 0.92). In addition, the cycle-by-cycle match between BSGM and transitions of gastric slow wave dysrhythmias was demonstrated. These results validate BSGM as a suitable method for noninvasively and accurately detecting gastric slow-wave spatiotemporal profiles from the body surface.NEW & NOTEWORTHY Gastric dysfunctions are associated with abnormalities in the gastric bioelectrical slow waves. Noninvasive detection of gastric slow waves from the body surface can be achieved through multichannel, high-resolution, body-surface gastric mapping (BSGM). BSGM matched the spatiotemporal characteristics of gastric slow waves recorded directly and simultaneously from the serosal surface of the stomach. Abnormal gastric slow waves, such as retrograde propagation, ectopic pacemaker, and colliding wavefronts can be detected by changes in the phase of BSGM.
Collapse
Affiliation(s)
- Stefan Calder
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand.,Alimetry Ltd., Auckland, New Zealand
| | - Leo K Cheng
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Christopher N Andrews
- Alimetry Ltd., Auckland, New Zealand.,Division of Gastroenterology and Hepatology, University of Calgary, Calgary, Alberta, Canada
| | | | | | | | - Jonathan C Erickson
- Department of Physics-Engineering, Washington and Lee University, Lexington, Virginia
| | - Armen Gharibans
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand.,Alimetry Ltd., Auckland, New Zealand
| | - Gregory O'Grady
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand.,Alimetry Ltd., Auckland, New Zealand
| | - Peng Du
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand.,Alimetry Ltd., Auckland, New Zealand
| |
Collapse
|
9
|
Gharibans AA, Calder S, Varghese C, Waite S, Schamberg G, Daker C, Du P, Alighaleh S, Carson D, Woodhead J, Farrugia G, Windsor JA, Andrews CN, O'Grady G. Gastric dysfunction in patients with chronic nausea and vomiting syndromes defined by a noninvasive gastric mapping device. Sci Transl Med 2022; 14:eabq3544. [PMID: 36130019 PMCID: PMC10042458 DOI: 10.1126/scitranslmed.abq3544] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Chronic nausea and vomiting syndromes (NVSs) are prevalent and debilitating disorders. Putative mechanisms include gastric neuromuscular disease and dysregulation of brain-gut interaction, but clinical tests for objectively defining gastric motor function are lacking. A medical device enabling noninvasive body surface gastric mapping (BSGM) was developed and applied to evaluate NVS pathophysiology. BSGM was performed in 43 patients with NVS and 43 matched controls using Gastric Alimetry (Alimetry), a conformable high-resolution array (8 × 8 electrodes; 20-mm interelectrode spacing), wearable reader, and validated symptom-logging app. Continuous measurement encompassed a fasting baseline (30 minutes), 482-kilocalorie meal, and 4-hour postprandial recording, followed by spectral and spatial biomarker analyses. Meal responses were impaired in NVS, with reduced amplitudes compared to controls (median, 23.3 microvolts versus 38.0 microvolts, P < 0.001), impaired fed-fasting power ratios (1.1 versus 1.6, P = 0.02), and disorganized slow waves (spatial frequency stability, 13.6 versus 49.5; P < 0.001). Two distinct NVS subgroups were evident with indistinguishable symptoms (all P > 0.05). Most patients (62%) had normal BSGM studies with increased psychological comorbidities (43.5% versus 7.7%; P = 0.03) and anxiety scores (median, 16.5 versus 13.0; P = 0.035). A smaller subgroup (31%) had markedly abnormal BSGM, with biomarkers correlating with symptoms (nausea, pain, excessive fullness, early satiety, and bloating; all r > 0.35, P < 0.05). Patients with NVS share overlapping symptoms but comprise distinct underlying phenotypes as revealed by a BSGM device. These phenotypes correlate with symptoms, which should inform clinical management and therapeutic trial design.
Collapse
Affiliation(s)
- Armen A Gharibans
- Surgical and Translational Research Centre, University of Auckland, Auckland 1023, New Zealand.,Alimetry Ltd., Auckland 1010, New Zealand.,Auckland Bioengineering Institute, University of Auckland, Auckland 1010, New Zealand
| | - Stefan Calder
- Surgical and Translational Research Centre, University of Auckland, Auckland 1023, New Zealand.,Alimetry Ltd., Auckland 1010, New Zealand
| | - Chris Varghese
- Surgical and Translational Research Centre, University of Auckland, Auckland 1023, New Zealand
| | | | | | - Charlotte Daker
- Department of Gastroenterology, North Shore Hospital, Auckland 0620, New Zealand
| | - Peng Du
- Alimetry Ltd., Auckland 1010, New Zealand.,Auckland Bioengineering Institute, University of Auckland, Auckland 1010, New Zealand
| | | | - Daniel Carson
- Surgical and Translational Research Centre, University of Auckland, Auckland 1023, New Zealand
| | | | | | - John A Windsor
- Surgical and Translational Research Centre, University of Auckland, Auckland 1023, New Zealand
| | - Christopher N Andrews
- Division of Gastroenterology, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 4N1, Canada
| | - Greg O'Grady
- Surgical and Translational Research Centre, University of Auckland, Auckland 1023, New Zealand.,Alimetry Ltd., Auckland 1010, New Zealand.,Auckland Bioengineering Institute, University of Auckland, Auckland 1010, New Zealand
| |
Collapse
|
10
|
Sukasem A, Calder S, Angeli-Gordon TR, Andrews CN, O’Grady G, Gharibans A, Du P. In vivo experimental validation of detection of gastric slow waves using a flexible multichannel electrogastrography sensor linear array. Biomed Eng Online 2022; 21:43. [PMID: 35761323 PMCID: PMC9238032 DOI: 10.1186/s12938-022-01010-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Accepted: 06/14/2022] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Cutaneous electrogastrography (EGG) is a non-invasive technique that detects gastric bioelectrical slow waves, which in part govern the motility of the stomach. Changes in gastric slow waves have been associated with a number of functional gastric disorders, but to date accurate detection from the body-surface has been limited due to the low signal-to-noise ratio. The main aim of this study was to develop a flexible active-electrode EGG array. Methods: Two Texas Instruments CMOS operational amplifiers: OPA2325 and TLC272BID, were benchtop tested and embedded in a flexible linear array of EGG electrodes, which contained four recording electrodes at 20-mm intervals. The cutaneous EGG arrays were validated in ten weaner pigs using simultaneous body-surface and serosal recordings, using the Cyton biosensing board and ActiveTwo acquisition systems. The serosal recordings were taken using a passive electrode array via surgical access to the stomach. Signals were filtered and compared in terms of frequency, amplitude, and phase-shift based on the classification of propagation direction from the serosal recordings. Results: The data were compared over 709 cycles of slow waves, with both active cutaneous EGG arrays demonstrating comparable performance. There was an agreement between frequencies of the cutaneous EGG and serosal recordings (3.01 ± 0.03 vs 3.03 ± 0.05 cycles per minute; p = 0.75). The cutaneous EGG also demonstrated a reduction in amplitude during abnormal propagation of gastric slow waves (310 ± 50 µV vs 277 ± 9 µV; p < 0.01), while no change in phase-shift was observed (1.28 ± 0.09 s vs 1.40 ± 0.10 s; p = 0.36). Conclusion: A sparse linear cutaneous EGG array was capable of reliably detecting abnormalities of gastric slow waves. For more accurate characterization of gastric slow waves, a two-dimensional body-surface array will be required.
Collapse
|
11
|
Patel B, Gizzi A, Hashemi J, Awakeem Y, Gregersen H, Kassab G. Biomechanical constitutive modeling of the gastrointestinal tissues: a systematic review. MATERIALS & DESIGN 2022; 217:110576. [PMID: 35935127 PMCID: PMC9351365 DOI: 10.1016/j.matdes.2022.110576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
The gastrointestinal (GI) tract is a continuous channel through the body that consists of the esophagus, the stomach, the small intestine, the large intestine, and the rectum. Its primary functions are to move the intake of food for digestion before storing and ultimately expulsion of feces. The mechanical behavior of GI tissues thus plays a crucial role for GI function in health and disease. The mechanical properties are characterized by a biomechanical constitutive model, which is a mathematical representation of the relation between load and deformation in a tissue. Hence, validated biomechanical constitutive models are essential to characterize and simulate the mechanical behavior of the GI tract. Here, a systematic review of these constitutive models is provided. This review is limited to studies where a model of the strain energy function is proposed to characterize the stress-strain relation of a GI tissue. Several needs are identified for more advanced modeling including: 1) Microstructural models that provide actual structure-function relations; 2) Validation of coupled electro-mechanical models accounting for active muscle contractions; 3) Human data to develop and validate models. The findings from this review provide guidelines for using existing constitutive models as well as perspective and directions for future studies.
Collapse
Affiliation(s)
- Bhavesh Patel
- California Medical Innovations Institute, 11107 Roselle St, San Diego, CA 92121, USA
| | - Alessio Gizzi
- Department of Engineering, Campus Bio-Medico University of Rome, Via A. del Portillo 21, 00128 Rome, IT
| | - Javad Hashemi
- California Medical Innovations Institute, 11107 Roselle St, San Diego, CA 92121, USA
| | - Yousif Awakeem
- California Medical Innovations Institute, 11107 Roselle St, San Diego, CA 92121, USA
| | - Hans Gregersen
- California Medical Innovations Institute, 11107 Roselle St, San Diego, CA 92121, USA
| | - Ghassan Kassab
- California Medical Innovations Institute, 11107 Roselle St, San Diego, CA 92121, USA
- Corresponding author , Tel: 001-858-249-7400, Fax: 001-858-249-7419, (Ghassan Kassab)
| |
Collapse
|
12
|
Varghese C, Carson DA, Bhat S, Hayes TCL, Gharibans AA, Andrews CN, O'Grady G. Clinical associations of functional dyspepsia with gastric dysrhythmia on electrogastrography: A comprehensive systematic review and meta-analysis. Neurogastroenterol Motil 2021; 33:e14151. [PMID: 33830590 DOI: 10.1111/nmo.14151] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 01/30/2021] [Accepted: 03/23/2021] [Indexed: 12/12/2022]
Abstract
BACKGROUND Functional dyspepsia (FD) is a common gastroduodenal disorder, yet its pathophysiology remains poorly understood. Bioelectrical gastric slow-wave abnormalities are thought to contribute to its multifactorial pathophysiology. Electrogastrography (EGG) has been used to record gastric electrical activity; however, the clinical associations require further evaluation. AIMS This study aimed to systematically assess the clinical associations of EGG in FD. METHODS MEDLINE, EMBASE, and CENTRAL databases were systematically searched for articles using EGG in adults with FD. Primary outcomes were percentage normal versus abnormal rhythm (bradygastria, normogastria, and tachygastria). Secondary outcomes were dominant power, dominant frequency, percentage coupling, and the meal responses. RESULTS 1751 FD patients and 555 controls from 47 studies were included. FD patients spent less time in normogastria while fasted (SMD -0.74; 95%CI -1.22 to -0.25) and postprandially (-0.86; 95%CI -1.35 to -0.37) compared with controls. FD patients also spent more fasted time in bradygastria (0.63; 95%CI 0.33-0.93) and tachygastria (0.45; 95%CI 0.12-0.78%). The power ratio (-0.17; 95%CI -0.83-0.48) and dominant frequency meal-response ratio (0.06; 95%CI -0.08-0.21) were not significantly different to controls. Correlations between EGG metrics and the presence and timing of FD symptoms were inconsistent. EGG methodologies were diverse and variably applied. CONCLUSION Abnormal gastric slow-wave rhythms are a consistent abnormality present in FD, as defined by EGG and, therefore, likely play a role in pathophysiology. The aberrant electrophysiology identified in FD warrants further investigation, including into underlying mechanisms, associated spatial patterns, and symptom correlations.
Collapse
Affiliation(s)
- Chris Varghese
- Department of Surgery, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Daniel A Carson
- Department of Surgery, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Sameer Bhat
- Department of Surgery, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Tommy C L Hayes
- Department of Surgery, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Armen A Gharibans
- Department of Surgery, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | | | - Greg O'Grady
- Department of Surgery, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| |
Collapse
|
13
|
O'Grady G, Gharibans AA, Du P, Huizinga JD. The gastric conduction system in health and disease: a translational review. Am J Physiol Gastrointest Liver Physiol 2021; 321:G527-G542. [PMID: 34549598 DOI: 10.1152/ajpgi.00065.2021] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Gastric peristalsis is critically dependent on an underlying electrical conduction system. Recent years have witnessed substantial progress in clarifying the operations of this system, including its pacemaking units, its cellular architecture, and slow-wave propagation patterns. Advanced techniques have been developed for assessing its functions at high spatiotemporal resolutions. This review synthesizes and evaluates this progress, with a focus on human and translational physiology. A current conception of the initiation and conduction of slow-wave activity in the human stomach is provided first, followed by a detailed discussion of its organization at the cellular and tissue level. Particular emphasis is then given to how gastric electrical disorders may contribute to disease states. Gastric dysfunction continues to grow in their prevalence and impact, and while gastric dysrhythmia is established as a clear and pervasive feature in several major gastric disorders, its role in explaining pathophysiology and informing therapy is still emerging. New insights from high-resolution gastric mapping are evaluated, together with historical data from electrogastrography, and the physiological relevance of emerging biomarkers from body surface mapping such as retrograde propagating slow waves. Knowledge gaps requiring further physiological research are highlighted.
Collapse
Affiliation(s)
- Gregory O'Grady
- Department of Surgery, The University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Armen A Gharibans
- Department of Surgery, The University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Peng Du
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Jan D Huizinga
- Department of Medicine, Farncombe Family Digestive Health Research Institute, McMaster University, Hamilton, Ontario, Canada
| |
Collapse
|
14
|
Ruenruaysab K, Calder S, Hayes T, Andrews C, OaGrady G, Gharibans A, Du P. Effects of anatomical variations of the stomach on body-surface gastric mapping investigated using a large population-based multiscale simulation approach. IEEE Trans Biomed Eng 2021; 69:1369-1377. [PMID: 34587001 DOI: 10.1109/tbme.2021.3116287] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The contractions of the stomach are governed by bioelectrical slow waves that can be detected non-invasively from the body-surface. Diagnosis of gastric motility disorders remains challenging due to the limited information provided by symptoms and tests, including standard electrogastrography (EGG). Body-surface gastric mapping (BSGM) is a novel technique that measures the resultant body-surface potentials using an array of multiple cutaneous electrodes. However, there is no established protocol to guide the placement of the mapping array and to account for the effects of biodiversity on the interpretation of gastric BSGM data. This study aims to quantify the effect of anatomical variation of the stomach on body surface potentials. To this end, 93 subject specific models of the stomach and torso were developed. Anatomical models were developed based on data obtained from the Cancer Imaging Archive. For each subject a set of points were created to model general anatomy the stomach and the torso, using a finite element mesh. A bidomain model was used to simulate the gastric slow waves in the antegrade wave (AW) direction and formation of colliding waves (CW). The resultant dipole was calculated, and a forward modeling approach was employed to simulate body-surface potentials. Simulated data were sampled from a 55 array of electrodes from the body-surface and compared between AW and CW cases. Anatomical parameters such as the Euclidean distance from the xiphoid process (8.6 2.2 cm), orientation relative to the axial plane (195 20.0) were quantified. Electrophysiological simulations of AW and CW were both correlated to specific metrics derived from BSGM signals. In general, the maximum amplitude () and orientation () of the signals provided consistent separation of AW and CW. The findings of this study will aid gastric BSGM electrode array design and placement protocol in clinical practices.
Collapse
|
15
|
Electrogastrography Abnormalities in Pediatric Gastroduodenal Disorders: A Systematic Review and Meta-analysis. J Pediatr Gastroenterol Nutr 2021; 73:9-16. [PMID: 33797449 DOI: 10.1097/mpg.0000000000003140] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Electrogastrography (EGG) is a non-invasive method of measuring gastric electrophysiology. Abnormal gastric electrophysiology is thought to contribute to disease pathophysiology in patients with gastroduodenal symptoms but this has not been comprehensively quantified in pediatric populations. This study aimed to quantify the abnormalities in gastric electrophysiology on EGG in neonatal and pediatric patients.Databases were systematically searched for articles utilizing EGG in neonatal and pediatric patients (≤18 years). Primary outcomes were prevalence of abnormality, percentage of time in normal rhythm, and power ratio. Secondary outcomes were correlations between patient symptoms and abnormal gastric electrophysiology on EGG.A total of 33 articles (1444 participants) were included. EGG methodologies were variable. Pooled prevalence of abnormalities on EGG ranged from 61% to 86% in patients with functional dyspepsia (FD), gastro-esophageal reflux disease (GERD), and type 1 diabetes mellitus (T1DM). FD patients averaged 20.8% (P = 0.011) less preprandial and 21.6% (P = 0.031) less postprandial time in normogastria compared with controls. Electrophysiological abnormalities were inconsistent in GERD. T1DM patients averaged 46.2% (P = 0.0003) less preprandial and similar (P = 0.32) postprandial time in normogastria compared with controls, and had a lower power ratio (SMD -2.20, 95% confidence interval [CI]: -4.25 to -0.15; P = 0.036). Symptom correlations with gastric electrophysiology were inconsistently reported.Abnormalities in gastric electrophysiology were identifiable across a range of pediatric patients with gastroduodenal symptoms on meta-analysis. However, techniques have been inconsistent, and standardized and more reliable EGG methods are desirable to further define these findings and their potential utility in clinical practice.
Collapse
|
16
|
Komorowski D, Mika B. Gastric slow wave rhythm identification using new approach based on noise-assisted multivariate empirical mode decomposition and Hilbert-Huang transform. Neurogastroenterol Motil 2021; 33:e13997. [PMID: 33043542 DOI: 10.1111/nmo.13997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Revised: 08/24/2020] [Accepted: 09/02/2020] [Indexed: 02/08/2023]
Abstract
BACKGROUND Electrogastrography (EGG) is the method of cutaneous recording of the myoelectrical activity of the stomach. A multi-channel signal is recorded non-invasively by means of electrodes placed outside the epigastric area. The normal electrical rhythm of the stomach (slow wave) may become significantly disturbed due to disorders of gastrointestinal tract. Abnormally fast electrical rhythms are termed tachygastria, while abnormally slow rhythms are known as bradygastria. Because some features of biological signals may go undetected using the classical methods of signal spectral analysis, we propose a new method for EGG rhythm identification. METHODS In this study, the calculation of the basic rhythms of multi-channel EGG signals is performed by means of the noise-assisted multivariate empirical mode decomposition (NA-MEMD) and Hilbert-Huang transform (HHT), using EGG data from eight healthy subjects. The results were compared with those obtained using classical spectral analysis. KEY RESULTS The mean values of the normogastric index for preprandial and two postprandial stages were found to be 64.78 ± 11.37%, 61.29 ± 15.86%, and 63.80 ± 13.24%, respectively. The obtained values of normogastric index are consistent with the normal human physiological value, which is approximately 70% for healthy subjects. CONCLUSIONS This method is able to capture features of the signal which are mostly undetectable by standard EGG processing methods. The EGG dominant rhythm identification using the instantaneous normogastric, bradygastric, and tachygastric indices provides new insights into biological EGG patterns.
Collapse
Affiliation(s)
- Dariusz Komorowski
- Department of Biosensors and Processing of Biomedical Signals, Faculty of Biomedical Engineering, Silesian University of Technology, Zabrze, Poland
| | - Barbara Mika
- Department of Biosensors and Processing of Biomedical Signals, Faculty of Biomedical Engineering, Silesian University of Technology, Zabrze, Poland
| |
Collapse
|
17
|
Carson DA, O'Grady G, Du P, Gharibans AA, Andrews CN. Body surface mapping of the stomach: New directions for clinically evaluating gastric electrical activity. Neurogastroenterol Motil 2021; 33:e14048. [PMID: 33274564 DOI: 10.1111/nmo.14048] [Citation(s) in RCA: 45] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 10/11/2020] [Accepted: 11/03/2020] [Indexed: 12/12/2022]
Abstract
BACKGROUND Gastric motility disorders, which include both functional and organic etiologies, are highly prevalent. However, there remains a critical lack of objective biomarkers to guide efficient diagnostics and personalized therapies. Bioelectrical activity plays a fundamental role in coordinating gastric function and has been investigated as a contributing mechanism to gastric dysmotility and sensory dysfunction for a century. However, conventional electrogastrography (EGG) has not achieved common clinical adoption due to its perceived limited diagnostic capability and inability to impact clinical care. The last decade has seen the emergence of novel high-resolution methods for invasively mapping human gastric electrical activity in health and disease, providing important new insights into gastric physiology. The limitations of EGG have also now become clearer, including the finding that slow-wave frequency alone is not a reliable discriminator of gastric dysrhythmia, shifting focus instead toward altered spatial patterns. Recently, advances in bioinstrumentation, signal processing, and computational modeling have aligned to allow non-invasive body surface mapping of the stomach to detect spatiotemporal gastric dysrhythmias. The clinical relevance of this emerging strategy to improve diagnostics now awaits determination. PURPOSE This review evaluates these recent advances in clinical gastric electrophysiology, together with promising emerging data suggesting that novel gastric electrical signatures recorded at the body surface (termed "body surface mapping") may correlate with symptoms. Further technological progress and validation data are now awaited to determine whether these advances will deliver on the promise of clinical gastric electrophysiology diagnostics.
Collapse
Affiliation(s)
- Daniel A Carson
- Department of Surgery, University of Auckland, Auckland, New Zealand
| | - Greg O'Grady
- Department of Surgery, University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Peng Du
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Department of Engineering Science, University of Auckland, Auckland, New Zealand
| | - Armen A Gharibans
- Department of Surgery, University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | | |
Collapse
|
18
|
Eichler CE, Cheng LK, Paskaranandavadivel N, Du P, Bradshaw LA, Avci R. Effects of magnetogastrography sensor configurations in tracking slow wave propagation. Comput Biol Med 2020; 129:104169. [PMID: 33338892 DOI: 10.1016/j.compbiomed.2020.104169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 11/19/2020] [Accepted: 12/03/2020] [Indexed: 10/22/2022]
Abstract
Magnetogastrography (MGG) is a non-invasive method of assessing gastric slow waves (SWs) by recording the resultant magnetic fields. MGG can capture both SW frequency and propagation, and identify SW dysrhythmias that are associated with motility disorders. However, the impact of the restricted spatial coverage and sensor density on SW propagation tracking performance is unknown. This study simulated MGG using multiple anatomically specific torso geometries and two realistic SW propagation patterns to determine the effect of different sensor configurations on tracking SW propagation. The surface current density mapping and center-of-gravity tracking methods were used to compare four magnetometer array configurations: a reference system currently used in GI research and three hypothetical higher density and coverage arrays. SW propagation patterns identified with two hypothetical arrays (with coverage over at least the anterior of the torso) correlated significantly higher with simulated realistic 3 cycle-per-minute SW activity than the reference array (p = 0.016, p = 0.005). Furthermore, results indicated that most of the magnetic fields that contribute to the performance of SW propagation tracking were located on the anterior of the torso as further increasing the coverage did not significantly increase performance. A 30% decrease in sensor spacing within the same spatial coverage of the reference array also significantly increased correlation values by approximately 0.50 when the signal-to-noise ratio was 5 dB. This study provides evidence that higher density and coverage sensor layouts will improve the utility of MGG. Further work is required to investigate optimum sensor configurations across larger anatomical variations and other SW propagation patterns.
Collapse
Affiliation(s)
- Chad E Eichler
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Leo K Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand; Department of Surgery, Vanderbilt University, Nashville, TN, USA
| | | | - Peng Du
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | | | - Recep Avci
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.
| |
Collapse
|
19
|
Detection of gastric slow oscillatory contraction using parasagittal cine MR images: Comparison with simultaneously measured electrogastrogram. Magn Reson Imaging 2020; 75:149-155. [PMID: 33137456 DOI: 10.1016/j.mri.2020.10.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Revised: 10/24/2020] [Accepted: 10/26/2020] [Indexed: 11/22/2022]
Abstract
PURPOSE To determine if parasagittal gastric cine magnetic resonance imaging (MRI) is able to measure gastric oscillatory contractions around 0.05 Hz and to determine its relationship with electrical activity as measured by electrogastrography (EGG). METHODS Assessment of the gastric motility is important for the research of the enteric nervous system and for the diagnosis of functional gastric disorders. Electrogastrography is a non-invasive method that can measure gastric oscillatory electrical activity around 0.05 Hz (slow wave) using electrodes on the abdominal skin, but its sensitivity and specificity of the slow wave detection is limited. We used parasagittal gastric cine MRI around the angular incisure to measure gastric oscillatory contraction around 0.05 Hz in 24 healthy volunteers. Cine MRI was acquired with time resolution of 1 s for 10 min while freely breathing participants were lying on the bed. The gastric area of the cross section was measured for each MR image and assessed its change over time. The results were compared with those for simultaneously recorded EGG. RESULTS The main frequency of the gastric area change for each participant ranged from 0.041 to 0.059 Hz (mean ± S.D. = 0.049 ± 0.004), which corresponds to the gastric slow wave frequency (mean ± S.D. = 0.049 ± 0.004) as measured by EGG (p = 7.9585 × 10 -8, Kendall 's tau test). Cross correlation analysis showed that 22 of 24 participants' gastric area changes were significantly (p < 0.05) related to the EGG waveforms. Displacement of the stomach due to respiration did not affect gastric area measurements. CONCLUSIONS Parasagittal cine MRI is correlated with EGG recordings and able to detect and quantifying gastric motility abnormalities.
Collapse
|
20
|
Eichler CE, Cheng LK, Du P, Calder S, Paskaranandavadivel N, Bradshaw LA, Avci R. Simulation-based Analysis of Magnetogastrography Sensor Configurations for Characterizing Gastric Slow Wave Dysrhythmias. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:2512-2515. [PMID: 33018517 DOI: 10.1109/embc44109.2020.9175406] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The routine diagnosis of gastric motility disorders represents a significant problem to current clinical practice. Magnetogastrography (MGG) provides a non-invasive option for assessing gastric slow wave (SW) dysrhythmias that are associated with motility disorders. However, its ability to characterize SW propagation is impaired by the limited spatial coverage of existing superconducting quantum interference devices (SQUIDs). Recently developed optically-pumped magnetometers can potentially substitute SQUIDs and enable subject-specific MGG arrays with greater spatial coverage. This study developed simulations of gastric MGG to determine the distribution of the magnetic fields (MFs) generated by SWs above the torso, and investigated the impact of several realistic dysrhythmic patterns of propagation. The distribution of MFs was found to vary significantly for different patterns of SW propagation, with ectopic dysrhythmia displaying the greatest difference from normal. Notably, some important proportion of the MFs lay outside the coverage of an existing experimental SQUID array used in gastrointestinal research for some simulated SW propagation patterns, such as retrograde activity. Results suggest that MGG measurements should be made over the entire frontal face of the torso to capture all of the strongest MFs generated by SWs.Clinical relevance- This provides a guide for the placement of MGG sensors for the capture of both normal and dysrhythmic gastric slow wave propagation.
Collapse
|
21
|
Ruenruaysab K, Calder S, Hayes T, O'Grady G, Gharibans A, Du P. Effects of Anatomical Variations on Body Surface Gastric Mapping. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:2388-2391. [PMID: 33018487 DOI: 10.1109/embc44109.2020.9176493] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The contractions of the stomach are governed by an electrophysiological event that can be detected noninvasively from the body-surface. Diagnosis of gastric motility disorders remains challenging due to the limited information provided by symptoms and standard electrogastrography (EGG). Body-surface gastric mapping (BSGM) is a novel technique that measures the resultant body-surface potentials using an array of multiple cutaneous electrodes. However, there is no established protocol to guide the placement of the mapping array and to account for the effects of biodiversity on the interpretation of gastric BSGM data. This study aims to quantify the effect of anatomical variation of the stomach on body-surface potentials. To this end, 44 subject specific models of the stomach and torso were developed. Anatomical parameters such as the Euclidean distance from the xiphoid process (88.1 ± 21.9 mm), orientation relative to the axial plane (202.8 ± 14.0°) and tissue volume (47.5 ± 29.5 mL) were quantified. Electrophysiological simulations demonstrated strong correlation (0.73 ± 0.16) between stomach and body-surface activities, with variations in the location of maximum amplitude relative to the xiphoid process (103.7 ± 44.2 mm). In general, there was an agreement between the location of the stomach and the location of the maximum amplitude, and an extended coverage was required to account for the biodiversity. The findings of this study will aid BSGM electrode array design and placement protocol in clinical practices.
Collapse
|
22
|
Calder S, O'Grady G, Cheng LK, Du P. A Simulated Anatomically Accurate Investigation Into the Effects of Biodiversity on Electrogastrography. IEEE Trans Biomed Eng 2020; 67:868-875. [DOI: 10.1109/tbme.2019.2922449] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
23
|
Avci R, Paskaranandavadivel N, Calder S, Du P, Bradshaw LA, Cheng LK. Source localization for gastric electrical activity using simulated magnetogastrographic data. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:2336-2339. [PMID: 31946368 DOI: 10.1109/embc.2019.8857384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
In this study, the use of magnetic dipole (MDP) approximation to localize the underlying source of magnetogastrographic (MGG) data was investigated. An anatomically realistic torso and a stomach model were used to simulate slow wave (SW) activities and magnetic fields (MFs). SW activity in the stomach was simulated using a grid-based finite element method. The SW activity at each time sample was represented by the dipoles generated for each element and MFs were computed from these dipoles including secondary sources in the torso. Gaussian noise was added to the MFs to represent experimental signal noise. MDP fitting was executed on the time samples of selected 2-second time frames, and goodness of fit (GOF) and the distance from the fitted MDP to the center of gravity (COG) of active dipoles were computed. Then, for each time frame, the spatial changes of COG and MDP positions in x-, y-, and z-directions and correlation scores were computed. Our results showed that MDP fitting was capable of identifying propagation patterns with mean correlation scores of 0.63 ± 0.30, 0.71 ± 0.19, and 0.81 ± 0.24 in x-, y-, and z-directions, respectively. The mean distance from COGs to the identified MDPs was 49±4 mm. The results were similar under the noise conditions as well. Our results suggest that source localization using MDP approximation can be useful to identify the propagation characteristics of SWs using MGG data.
Collapse
|
24
|
Abstract
This review covers the epidemiology, pathophysiology, clinical features, diagnosis, and management of diabetic gastroparesis, and more broadly diabetic gastroenteropathy, which encompasses all the gastrointestinal manifestations of diabetes mellitus. Up to 50% of patients with type 1 and type 2 DM and suboptimal glycemic control have delayed gastric emptying (GE), which can be documented with scintigraphy, 13C breath tests, or a wireless motility capsule; the remainder have normal or rapid GE. Many patients with delayed GE are asymptomatic; others have dyspepsia (i.e., mild to moderate indigestion, with or without a mild delay in GE) or gastroparesis, which is a syndrome characterized by moderate to severe upper gastrointestinal symptoms and delayed GE that suggest, but are not accompanied by, gastric outlet obstruction. Gastroparesis can markedly impair quality of life, and up to 50% of patients have significant anxiety and/or depression. Often the distinction between dyspepsia and gastroparesis is based on clinical judgement rather than established criteria. Hyperglycemia, autonomic neuropathy, and enteric neuromuscular inflammation and injury are implicated in the pathogenesis of delayed GE. Alternatively, there are limited data to suggest that delayed GE may affect glycemic control. The management of diabetic gastroparesis is guided by the severity of symptoms, the magnitude of delayed GE, and the nutritional status. Initial options include dietary modifications, supplemental oral nutrition, and antiemetic and prokinetic medications. Patients with more severe symptoms may require a venting gastrostomy or jejunostomy and/or gastric electrical stimulation. Promising newer therapeutic approaches include ghrelin receptor agonists and selective 5-hydroxytryptamine receptor agonists.
Collapse
Affiliation(s)
- Adil E Bharucha
- Clinical Enteric Neuroscience Translational and Epidemiological Research Program, Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota
| | - Yogish C Kudva
- Division of Endocrinology. Mayo Clinic, Rochester, Minnesota
| | - David O Prichard
- Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
25
|
Wang THH, Angeli TR, Beban G, Du P, Bianco F, Gibbons SJ, Windsor JA, Cheng LK, O’Grady G. Slow-wave coupling across a gastroduodenal anastomosis as a mechanism for postsurgical gastric dysfunction: evidence for a "gastrointestinal aberrant pathway". Am J Physiol Gastrointest Liver Physiol 2019; 317:G141-G146. [PMID: 31169993 PMCID: PMC6734376 DOI: 10.1152/ajpgi.00002.2019] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Postsurgical gastric dysfunction is common, but the mechanisms are varied and poorly understood. The pylorus normally acts as an electrical barrier isolating gastric and intestinal slow waves. In this report, we present an aberrant electrical conduction pathway arising between the stomach and small intestine, following pyloric excision and surgical anastomosis, as a novel disease mechanism. A patient was referred with postsurgical gastroparesis following antrectomy, gastroduodenostomy, and vagotomy for peptic ulceration. Scintigraphy confirmed markedly abnormal 4-h gastric retention. Symptoms included nausea, vomiting, postprandial distress, and reflux. Intraoperative, high-resolution electrical mapping was performed across the anastomosis immediately before revision gastrectomy, and the resected anastomosis underwent immunohistochemistry for interstitial cells of Cajal. Mapping revealed continuous, stable abnormal retrograde slow-wave propagation through the anastomosis, with slow conduction occurring at the scar (4.0 ± 0.1 cycles/min; 2.5 ± 0.6 mm/s; 0.26 ± 0.15 mV). Stable abnormal retrograde propagation continued into the gastric corpus with tachygastria (3.9 ± 0.2 cycles/min; 1.6 ± 0.5 mm/s; 0.19 ± 0.12 mV). Histology confirmed ingrowth of atypical ICC through the scar, defining an aberrant pathway enabling transanastomotic electrical conduction. In conclusion, a "gastrointestinal aberrant pathway" is presented as a novel proposed cause of postsurgical gastric dysfunction. The importance of aberrant anastomotic conduction in acute and long-term surgical recovery warrants further investigation.NEW & NOTEWORTHY High-resolution gastric electrical mapping was performed during revisional surgery in a patient with severe gastric dysfunction following antrectomy and gastroduodenostomy. The results revealed continuous propagation of slow waves from the duodenum to the stomach, through the old anastomotic scar, and resulting in retrograde-propagating tachygastria. Histology showed atypical interstitial cells of Cajal growth through the anastomotic scar. Based on these results, we propose a "gastrointestinal aberrant pathway" as a mechanism for postsurgical gastric dysfunction.
Collapse
Affiliation(s)
- Tim H.-H. Wang
- 1Department of Surgery, University of Auckland, Auckland, New Zealand
| | - Timothy R. Angeli
- 2Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Grant Beban
- 3Department of General Surgery, Auckland City Hospital, Auckland, New Zealand
| | - Peng Du
- 2Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Francesca Bianco
- 4Enteric Neuroscience Program, Mayo Clinic, Rochester, Minnesota,5Departments of Medical and Surgical Sciences (DIMEC) and Veterinary Medical Sciences, University of Bologna, Bologna, Italy
| | - Simon J. Gibbons
- 4Enteric Neuroscience Program, Mayo Clinic, Rochester, Minnesota
| | - John A. Windsor
- 1Department of Surgery, University of Auckland, Auckland, New Zealand
| | - Leo K. Cheng
- 2Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand,6Department of Surgery, Vanderbilt University, Nashville, Tennessee
| | - Gregory O’Grady
- 1Department of Surgery, University of Auckland, Auckland, New Zealand,2Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| |
Collapse
|
26
|
Farajidavar A. Bioelectronics for mapping gut activity. Brain Res 2019; 1693:169-173. [PMID: 29903619 DOI: 10.1016/j.brainres.2018.03.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2017] [Revised: 03/01/2018] [Accepted: 03/02/2018] [Indexed: 12/18/2022]
Abstract
Gastric peristalsis is initiated and coordinated by an underlying bioelectrical activity, termed slow waves. High-resolution (HR) mapping of the slow waves has become a fundamental tool for accurately defining electrophysiological properties in gastroenterology, including dysrhythmias in gastric disorders such as gastroparesis and functional dyspepsia. Currently, HR mapping is achieved via acquisition of slow waves taken directly from the serosa of fasted subjects undergoing invasive abdominal surgery. Recently, a minimally invasive retractable catheter and electrode has been developed for HR mapping that can only be used in short-term studies in subjects undergoing laparoscopy. Noninvasive mapping has also emerged from multichannel cutaneous electrogastrography; however, it lacks sufficient resolution and is prone to artifacts. Bioelectronics that can map slow waves in conscious subjects, postprandially and long-term, are in high demand. Due to the low signal-to-noise ratio of cutaneous electrogastrography, electrodes for HR mapping of gut activity have to acquire slow waves directly from the gut; hence, development of novel device implantation methods has inevitably accompanied development of the devices themselves. Initial efforts that have paved the way toward achieving these goals have included development of miniature wireless systems with a limited number of acquisition channels using commercially available off-the-shelf electronic components, flexible HR electrodes, and endoscopic methods for minimally invasive device implantation. To further increase the spatial resolution of HR mapping, and to minimize the size and power consumption of the implant for long-term studies, application-specific integrated circuitry, wireless power transfer, and stretchable electronics technologies have had to be integrated into a single system.
Collapse
Affiliation(s)
- Aydin Farajidavar
- Department of Electrical and Computer Engineering, New York Institute of Technology, Room 226B, Schure Hall, Northern Blvd, Old Westbury, NY 11568-8000, USA.
| |
Collapse
|
27
|
Popović NB, Miljković N, Popović MB. Simple gastric motility assessment method with a single-channel electrogastrogram. ACTA ACUST UNITED AC 2019; 64:177-185. [PMID: 29708873 DOI: 10.1515/bmt-2017-0218] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Accepted: 03/22/2018] [Indexed: 11/15/2022]
Abstract
Surface electrogastrography (EGG) is a non-invasive technique that is used to record myoelectrical activity of the stomach using cutaneous electrodes placed on the abdomen. Gastric motility assessment by EGG is a candidate for standard clinical procedure based on the quantification of parameters characteristic of gastric motility disorders. Despite its noticeable benefits, EGG is not widely implemented in clinical practice. The main reasons are: (1) lack of standardization of electrode placement, (2) time-consuming diagnostic procedures and (3) a complex multi-channel recording setup. We proposed a methodology in which an easy-to-use single-channel EGG, with a less time-consuming protocol (<1 h), would provide sufficient information for gastric motility assessment. Recordings from the three anatomical landmarks in 20 healthy young subjects were compared under two conditions, fasting and postprandial by evaluating the dominant frequency (DF). Our results showed that there is a statistically significant increase of DF after meal ingestion (p<0.05) in each of the three channels. However, when the study group was divided into two subgroups based on body mass index (BMI), the most appropriate recording location was above the body of the stomach (according to statistical significance p=7.82×10-6). We showed that a less time-consuming recording session with light meal intake could be used for the assessment of gastric myoelectrical activity (GMA).
Collapse
Affiliation(s)
- Nenad B Popović
- University of Belgrade - School of Electrical Engineering, Bulevar kralja Aleksandra 73, 11000 Belgrade, Serbia
| | - Nadica Miljković
- University of Belgrade - School of Electrical Engineering, Bulevar kralja Aleksandra 73, 11000 Belgrade, Serbia
| | - Mirjana B Popović
- University of Belgrade - School of Electrical Engineering, Bulevar kralja Aleksandra 73, 11000 Belgrade, Serbia.,University of Belgrade - Institute for Medical Research, Dr Subotića starijeg 4, 11000 Belgrade, Serbia
| |
Collapse
|
28
|
Wells CI, O'Grady G, Bissett IP. Colonic Electromechanical Abnormalities Underlying Post-operative Ileus: A Systematic and Critical Review. J Neurogastroenterol Motil 2019; 25:36-47. [PMID: 30504526 PMCID: PMC6326204 DOI: 10.5056/jnm18030] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Revised: 06/20/2018] [Accepted: 07/21/2018] [Indexed: 12/25/2022] Open
Abstract
Post-operative ileus (POI) is an inevitable consequence of major abdominal surgery, and may be prolonged in up to 30% of patients. Ileus is commonly presumed to result from paralysis of the GI tract, though there is little direct evidence to support this view. The aim of this review is to systematically search and critically review the literature investigating post-operative colonic electrical and mechanical activity. MEDLINE and Embase databases were systematically searched for articles investigating post-operative colonic motor or electrical activity in human patients. Nineteen original articles investigating post-operative colonic motor or electrical activity were identified. Most studies have used low-resolution techniques, with intermittent recordings of colonic motility. Numerous studies have shown that colonic electrical and motor activity does not cease routinely following surgery, but is of abnormal character for 3–6 days following laparotomy. One recent high-resolution manometry study identified hyperactive cyclic motor patterns occurring in the distal colon on the first post-operative day. Low-resolution studies have shown colonic slow waves are not inhibited by surgery, and are present even in the immediate post-operative period. Recovery of normal motility appears to occur in a proximal to distal direction and is temporally correlated with the clinical return of bowel function. No studies have investigated motility specifically in prolonged POI. Future studies should use high-resolution techniques to accurately characterise abnormalities in electrical and mechanical function underlying POI, and correlate these changes with clinical recovery of bowel function.
Collapse
Affiliation(s)
- Cameron I Wells
- Department of Surgery, Faculty of Medical and Health Sciences, The University of Auckland, New Zealand
| | - Gregory O'Grady
- Department of Surgery, Faculty of Medical and Health Sciences, The University of Auckland, New Zealand.,Department of Surgery, Auckland District Health Board, Auckland, New Zealand.,Auckland Bioengineering Institute, The University of Auckland, New Zealand
| | - Ian P Bissett
- Department of Surgery, Faculty of Medical and Health Sciences, The University of Auckland, New Zealand.,Department of Surgery, Auckland District Health Board, Auckland, New Zealand
| |
Collapse
|
29
|
O'Grady G, Angeli TR, Paskaranandavadivel N, Erickson JC, Wells CI, Gharibans AA, Cheng LK, Du P. Methods for High-Resolution Electrical Mapping in the Gastrointestinal Tract. IEEE Rev Biomed Eng 2018; 12:287-302. [PMID: 30176605 DOI: 10.1109/rbme.2018.2867555] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Over the last two decades, high-resolution (HR) mapping has emerged as a powerful technique to study normal and abnormal bioelectrical events in the gastrointestinal (GI) tract. This technique, adapted from cardiology, involves the use of dense arrays of electrodes to track bioelectrical sequences in fine spatiotemporal detail. HR mapping has now been applied in many significant GI experimental studies informing and clarifying both normal physiology and arrhythmic behaviors in disease states. This review provides a comprehensive and critical analysis of current methodologies for HR electrical mapping in the GI tract, including extracellular measurement principles, electrode design and mapping devices, signal processing and visualization techniques, and translational research strategies. The scope of the review encompasses the broad application of GI HR methods from in vitro tissue studies to in vivo experimental studies, including in humans. Controversies and future directions for GI mapping methodologies are addressed, including emerging opportunities to better inform diagnostics and care in patients with functional gut disorders of diverse etiologies.
Collapse
|
30
|
Calder S, O’Grady G, Cheng LK, Du P. Torso-Tank Validation of High-Resolution Electrogastrography (EGG): Forward Modelling, Methodology and Results. Ann Biomed Eng 2018; 46:1183-1193. [DOI: 10.1007/s10439-018-2030-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Accepted: 04/16/2018] [Indexed: 02/07/2023]
|
31
|
Erickson JC, Hayes JA, Bustamante M, Joshi R, Rwagaju A, Paskaranandavadivel N, Angeli TR. Intsy: a low-cost, open-source, wireless multi-channel bioamplifier system. Physiol Meas 2018; 39:035008. [PMID: 29406314 DOI: 10.1088/1361-6579/aaad51] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
OBJECTIVE Multi-channel electrical recordings of physiologically generated signals are common to a wide range of biomedical fields. The aim of this work was to develop, validate, and demonstrate the practical utility of a high-quality, low-cost 32/64-channel bioamplifier system with real-time wireless data streaming capability. APPROACH The new 'Intsy' system integrates three main off-the-shelf hardware components: (1) Intan RHD2132 bioamplifier; (2) Teensy 3.2 microcontroller; and (3) RN-42 Bluetooth 2.1 module with a custom LabView interface for real-time data streaming and visualization. Practical utility was validated by measuring serosal gastric slow waves and surface EMG on the forearm with various contraction force levels. Quantitative comparisons were made to a gold-standard commercial system (Biosemi ActiveTwo). MAIN RESULTS Intsy signal quality was quantitatively comparable to that of the ActiveTwo. Recorded slow wave signals had high SNR (24 ± 2.7 dB) and wavefront propagation was accurately mapped. EMG spike bursts were characterized by high SNR (⩾10 dB) and activation timing was readily identified. Stable data streaming rates achieved were 3.5 kS s-1 for wireless and 64 kS s-1 for USB-wired transmission. SIGNIFICANCE Intsy has the highest channel count of any existing open-source, wireless-enabled module. The flexibility, portability and low cost ($1300 for the 32-channel version, or $2500 for 64 channels) of this new hardware module reduce the entry barrier for a range of electrophysiological experiments, as are typical in the gastrointestinal (EGG), cardiac (ECG), neural (EEG), and neuromuscular (EMG) domains.
Collapse
Affiliation(s)
- Jonathan C Erickson
- Department of Physics and Engineering, Washington and Lee University, Lexington, VA 24450, United States of America
| | | | | | | | | | | | | |
Collapse
|
32
|
Patterns of Abnormal Gastric Pacemaking After Sleeve Gastrectomy Defined by Laparoscopic High-Resolution Electrical Mapping. Obes Surg 2018; 27:1929-1937. [PMID: 28213666 DOI: 10.1007/s11695-017-2597-6] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Laparoscopic sleeve gastrectomy (LSG) is increasingly being applied to treat obesity. LSG includes excision of the normal gastric pacemaker, which could induce electrical dysrhythmias impacting on post-operative symptoms and recovery, but these implications have not been adequately investigated. This study aimed to define the effects of LSG on gastric slow-wave pacemaking using laparoscopic high-resolution (HR) electrical mapping. METHODS Laparoscopic HR mapping was performed before and after LSG using flexible printed circuit arrays (64-96 electrodes; 8-12 cm2; n = 8 patients) deployed through a 12 mm trocar and positioned on the gastric serosa. An additional patient with chronic reflux, nausea, and dysmotility 6 months after LSG also underwent gastric mapping while undergoing conversion to gastric bypass. Slow-wave activity was quantified by propagation pattern, frequency, velocity, and amplitude. RESULTS Baseline activity showed exclusively normal propagation. Acutely after LSG, all patients developed either a distal unifocal ectopic pacemaker with retrograde propagation (50%) or bioelectrical quiescence (50%). Propagation velocity was abnormally rapid after LSG (12.5 ± 0.8 vs baseline 3.8 ± 0.8 mm s-1; p = 0.01), whereas frequency and amplitude were unchanged (2.7 ± 0.3 vs 2.8 ± 0.3 cpm, p = 0.7; 1.7 ± 0.2 vs 1.6 ± 0.6 mV, p = 0.7). In the patient with chronic dysmotility after LSG, mapping also revealed a stable antral ectopic pacemaker with retrograde rapid propagation (12.6 ± 4.8 mm s-1). CONCLUSION Resection of the gastric pacemaker during LSG acutely resulted in aberrant distal ectopic pacemaking or bioelectrical quiescence. Ectopic pacemaking can persist long after LSG, inducing chronic dysmotility. The clinical and therapeutic significance of these findings now require further investigation.
Collapse
|
33
|
Du P, Calder S, Angeli TR, Sathar S, Paskaranandavadivel N, O'Grady G, Cheng LK. Progress in Mathematical Modeling of Gastrointestinal Slow Wave Abnormalities. Front Physiol 2018; 8:1136. [PMID: 29379448 PMCID: PMC5775268 DOI: 10.3389/fphys.2017.01136] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2017] [Accepted: 12/22/2017] [Indexed: 12/19/2022] Open
Abstract
Gastrointestinal (GI) motility is regulated in part by electrophysiological events called slow waves, which are generated by the interstitial cells of Cajal (ICC). Slow waves propagate by a process of "entrainment," which occurs over a decreasing gradient of intrinsic frequencies in the antegrade direction across much of the GI tract. Abnormal initiation and conduction of slow waves have been demonstrated in, and linked to, a number of GI motility disorders. A range of mathematical models have been developed to study abnormal slow waves and applied to propose novel methods for non-invasive detection and therapy. This review provides a general outline of GI slow wave abnormalities and their recent classification using multi-electrode (high-resolution) mapping methods, with a particular emphasis on the spatial patterns of these abnormal activities. The recently-developed mathematical models are introduced in order of their biophysical scale from cellular to whole-organ levels. The modeling techniques, main findings from the simulations, and potential future directions arising from notable studies are discussed.
Collapse
Affiliation(s)
- Peng Du
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Stefan Calder
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Timothy R. Angeli
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Shameer Sathar
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | | | - Gregory O'Grady
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
- Department of Surgery, University of Auckland, Auckland, New Zealand
| | - Leo K. Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
- Department of Surgery, Vanderbilt University, Nashville, TN, United States
| |
Collapse
|
34
|
Assessment of slow wave propagation in multichannel electrogastrography by using noise-assisted multivariate empirical mode decomposition and cross-covariance analysis. Comput Biol Med 2018; 100:305-315. [PMID: 29397919 DOI: 10.1016/j.compbiomed.2017.12.021] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2017] [Revised: 12/21/2017] [Accepted: 12/21/2017] [Indexed: 02/06/2023]
Abstract
Electrogastrography (EGG) is a noninvasive technique for recording the myoelectrical activity of the stomach. An electrogastrographic signal recorded by using a four-channel system with electrodes placed on the surface of the skin is a mixture of a low-frequency gastric pacesetter potential known as a slow wave, electrical activity from other organs, and random noise. The aim of this work was to investigate the possibility of detecting the propagation of the gastric slow wave from multichannel EGG data. Noise-assisted multivariate empirical mode decomposition (NA-MEMD) and cross-covariance analysis (CCA) are proposed as new detection tools. NA-MEMD was applied to attenuate the noise and extract the EGG signal from four channels, while CCA was performed to assess the time shift between the EGG signal channels. Validation of the method was performed using synthetic EGG signals and the methodology was tested on four young, healthy adults. After validation, the proposed method was applied for two kinds of human EGG data: 10-min (short) EGG data from the preprandial phase and 90-120-min (long) EGG data from the preprandial phase as well as the postprandial phase. The results obtained for both synthetic and human EGG data confirm that the proposed method could be a useful tool for assessing the propagation of slow waves. The time shift calculation from the preprandial phase of the EGG examination yielded more consistent results than the postprandial phase. The mean value of the slow wave time lag between neighbouring channels for synthetic data was found to be 4.99±0.47 s. In addition, it was confirmed that the proposed method, that is, NA-MEMD and CCA together, are robust to noise.
Collapse
|
35
|
Wang THH, Du P, Angeli TR, Paskaranandavadivel N, Erickson JC, Abell TL, Cheng LK, O'Grady G. Relationships between gastric slow wave frequency, velocity, and extracellular amplitude studied by a joint experimental-theoretical approach. Neurogastroenterol Motil 2018; 30. [PMID: 28695661 DOI: 10.1111/nmo.13152] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2017] [Accepted: 06/08/2017] [Indexed: 02/08/2023]
Abstract
BACKGROUND Gastric slow wave dysrhythmias are accompanied by deviations in frequency, velocity, and extracellular amplitude, but the inherent association between these parameters in normal activity still requires clarification. This study quantified these associations using a joint experimental-theoretical approach. METHODS Gastric pacing was conducted in pigs with simultaneous high-resolution slow wave mapping (32-256 electrodes; 4-7.6 mm spacing). Relationships between period, velocity, and amplitude were quantified and correlated for each wavefront. Human data from two existing mapping control cohorts were analyzed to extract and correlate these same parameters. A validated biophysically based ICC model was also applied in silico to quantify velocity-period relationships during entrainment simulations and velocity-amplitude relationships from membrane potential equations. KEY RESULTS Porcine pacing studies identified positive correlations for velocity-period (0.13 mm s-1 per 1 s, r2 =.63, P<.001) and amplitude-velocity (74 μV per 1 mm s-1 , r2 =.21, P=.002). In humans, positive correlations were also quantified for velocity-period (corpus: 0.11 mm s-1 per 1 s, r2 =.16, P<.001; antrum: 0.23 mm s-1 per 1 s, r2 =.55; P<.001), and amplitude-velocity (94 μV per 1 mm s-1 , r2 =.56; P<.001). Entrainment simulations matched the experimental velocity-period relationships and demonstrated dependence on the slow wave recovery phase. Simulated membrane potential relationships were close to these experimental results (100 μV per 1 mm s-1 ). CONCLUSIONS AND INFERENCES These data quantify the relationships between slow wave frequency, velocity, and extracellular amplitude. The results from both human and porcine studies were in keeping with biophysical models, demonstrating concordance with ICC biophysics. These relationships are important in the regulation of gastric motility and will help to guide interpretations of dysrhythmias.
Collapse
Affiliation(s)
- T H-H Wang
- Department of Surgery, University of Auckland, Auckland, New Zealand
| | - P Du
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - T R Angeli
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - N Paskaranandavadivel
- Department of Surgery, University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - J C Erickson
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Department of Physics-Engineering, Washington & Lee University, Lexington, VA, USA
| | - T L Abell
- Division of Gastroenterology, University of Louisville, Louisville, KY, USA
| | - L K Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Department of Surgery, Vanderbilt University, Nashville, TN, USA
| | - G O'Grady
- Department of Surgery, University of Auckland, Auckland, New Zealand.,Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| |
Collapse
|
36
|
Paskaranandavadivel N, Cheng LK, Du P, Rogers JM, O'Grady G. High-resolution mapping of gastric slow-wave recovery profiles: biophysical model, methodology, and demonstration of applications. Am J Physiol Gastrointest Liver Physiol 2017; 313:G265-G276. [PMID: 28546283 DOI: 10.1152/ajpgi.00127.2017] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2017] [Revised: 05/24/2017] [Accepted: 05/24/2017] [Indexed: 01/31/2023]
Abstract
Slow waves play a central role in coordinating gastric motor activity. High-resolution mapping of extracellular potentials from the stomach provides spatiotemporal detail on normal and dysrhythmic slow-wave patterns. All mapping studies to date have focused exclusively on tissue activation; however, the recovery phase contains vital information on repolarization heterogeneity, the excitable gap, and refractory tail interactions but has not been investigated. Here, we report a method to identify the recovery phase in slow-wave mapping data. We first developed a mathematical model of unipolar extracellular potentials that result from slow-wave propagation. These simulations showed that tissue repolarization in such a signal is defined by the steepest upstroke beyond the activation phase (activation was defined by accepted convention as the steepest downstroke). Next, we mapped slow-wave propagation in anesthetized pigs by recording unipolar extracellular potentials from a high-resolution array of electrodes on the serosal surface. Following the simulation result, a wavelet transform technique was applied to detect repolarization in each signal by finding the maximum positive slope beyond activation. Activation-recovery (ARi) and recovery-activation (RAi) intervals were then computed. We hypothesized that these measurements of recovery profile would differ for slow waves recorded during normal and spatially dysrhythmic propagation. We found that the ARi of normal activity was greater than dysrhythmic activity (5.1 ± 0.8 vs. 3.8 ± 0.7 s; P < 0.05), whereas RAi was lower (9.7 ± 1.3 vs. 12.2 ± 2.5 s; P < 0.05). During normal propagation, RAi and ARi were linearly related with negative unit slope indicating entrainment of the entire mapped region. This relationship was weakened during dysrhythmia (slope: -0.96 ± 0.2 vs -0.71 ± 0.3; P < 0.05).NEW & NOTEWORTHY The theoretical basis of the extracellular gastric slow-wave recovery phase was defined using mathematical modeling. A novel technique utilizing the wavelet transform was developed and validated to detect the extracellular slow-wave recovery phase. In dysrhythmic wavefronts, the activation-to-recovery interval (ARi) was shorter and recovery-to-activation interval (RAi) was longer compared with normal wavefronts. During normal activation, RAi vs. ARi had a slope of -1, whereas the weakening of the slope indicated a dysrhythmic propagation.
Collapse
Affiliation(s)
- N Paskaranandavadivel
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand; .,Department of Surgery, University of Auckland, Auckland, New Zealand
| | - L K Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Department of Surgery, Vanderbilt University, Nashville, Tennessee; and
| | - P Du
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - J M Rogers
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, Alabama
| | - G O'Grady
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Department of Surgery, University of Auckland, Auckland, New Zealand
| |
Collapse
|