Zheng M, Lou F, Huang Y, Pan S, Zhang X. MR-based electrical property tomography using a physics-informed network at 3 and 7 T. NMR IN BIOMEDICINE 2024; 37:e5137. [PMID: 38439522 DOI: 10.1002/nbm.5137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 01/29/2024] [Accepted: 02/11/2024] [Indexed: 03/06/2024]
Abstract
Magnetic resonance electrical propert tomography promises to retrieve electrical properties (EPs) quantitatively and non-invasively in vivo, providing valuable information for tissue characterization and pathology diagnosis. However, its clinical implementation has been hindered by, for example, B1 measurement accuracy, reconstruction artifacts resulting from inaccuracies in underlying models, and stringent hardware/software requirements. To address these challenges, we present a novel approach aimed at accurate and high-resolution EPs reconstruction based on water content maps by using a physics-informed network (PIN-wEPT). The proposed method utilizes standard clinical protocols and conventional multi-channel receive arrays that have been routinely equipped in clinical settings, thus eliminating the need for specialized RF sequence/coil configurations. Compared with the original wEPT method, the network generates accurate water content maps that effectively eliminate the influence ofB → 1 + andB → 1 - by incorporating data mismatch with electrodynamic constraints derived from the Helmholtz equation. Subsequent regression analysis develops a broad relationship between water content and EPs across various types of brain tissue. A series of numerical simulations was conducted at 7 T to assess the feasibility and performance of the method, which encompassed four normal head models and models with tumorous tissues incorporated, and the results showed normalized mean square error below 1.0% in water content, below 11.7% in conductivity, and below 1.1% in permittivity reconstructions for normal brain tissues. Moreover, in vivo validations conducted over five healthy subjects at both 3 and 7 T showed reasonably good consistency with empirical EPs values across the white matter, gray matter, and cerebrospinal fluid. The PIN-wEPT method, with its demonstrated efficacy, flexibility, and compatibility with current MRI scanners, holds promising potential for future clinical application.
Collapse
Affiliation(s)
- Mengxuan Zheng
- Interdisciplinary Institute of Neuroscience and Technology, Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China
- MOE Frontier Science Center for Brain Science and Brain-Machine Integration, Zhejiang University, Hangzhou, China
| | - Feiyang Lou
- MOE Frontier Science Center for Brain Science and Brain-Machine Integration, Zhejiang University, Hangzhou, China
- School of Medicine, Zhejiang University, Hangzhou, China
| | - Yiman Huang
- MOE Frontier Science Center for Brain Science and Brain-Machine Integration, Zhejiang University, Hangzhou, China
- College of Electrical Engineering, Zhejiang University, Hangzhou, China
| | - Sihong Pan
- MOE Frontier Science Center for Brain Science and Brain-Machine Integration, Zhejiang University, Hangzhou, China
- College of Electrical Engineering, Zhejiang University, Hangzhou, China
| | - Xiaotong Zhang
- Interdisciplinary Institute of Neuroscience and Technology, Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China
- MOE Frontier Science Center for Brain Science and Brain-Machine Integration, Zhejiang University, Hangzhou, China
- School of Medicine, Zhejiang University, Hangzhou, China
- College of Electrical Engineering, Zhejiang University, Hangzhou, China
- Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, China
| |
Collapse
|
2
|
Çan MK, Ider YZ. Bias correction for phase-based cr-MREPT using low resolution B1+ magnitude. Phys Med Biol 2024; 69:125020. [PMID: 38830364 DOI: 10.1088/1361-6560/ad53a1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Accepted: 06/03/2024] [Indexed: 06/05/2024]
Abstract
ObjectiveFull-form Magnetic Resonance Electrical Properties Tomography (MREPT) requires bothB1+magnitude and phase information. SinceB1+phase can be obtained faster and with higher SNR compared toB1+magnitude, several phase-based methods have been developed for conductivity imaging. However, phase-based methods suffer from a concave bias due to the assumption that∇|B1+|is negligible in the ROI.ApproachIn this paper, we re-derive the central equation of phase-based cr-MREPT without assuming that∇|B1+|is negligible and thus propose a correction method directly integrated into the equation system.Main resultsProposed method successfully corrects the concave bias on both simulated and experimental data and significantly increases image quality.SignificanceThe proposed correction method depends on a very low-resolution|B1+|map, and therefore the imaging time does not increase significantly for obtainingB1+magnitude. Moreover, correction can be achieved using simulatedB1+magnitude, hence completely removing the additional imaging requirement.
Collapse
Affiliation(s)
- Mustafa Kaan Çan
- Department of Electrical and Electronics Engineering, Bilkent University, 06800 Ankara, Turkey
| | - Yusuf Ziya Ider
- Department of Biomedical Engineering, Başkent University, 06790 Ankara, Turkey
| |
Collapse
|
3
|
Bijvoet GP, Nies HMJM, Holtackers RJ, Martens BM, Smink J, Linz D, Vernooy K, Wildberger JE, Nijveldt R, Chaldoupi SM, Mihl C. Tissue characterization of acute lesions during cardiac magnetic resonance-guided ablation of cavo-tricuspid isthmus-dependent atrial flutter: a feasibility study. Eur Heart J Cardiovasc Imaging 2024; 25:635-644. [PMID: 38156446 PMCID: PMC11057941 DOI: 10.1093/ehjci/jead334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 10/18/2023] [Accepted: 11/28/2023] [Indexed: 12/30/2023] Open
Abstract
AIMS To characterize acute lesions during cardiac magnetic resonance (CMR)-guided radiofrequency (RF) ablation of cavo-tricuspid isthmus (CTI)-dependent atrial flutter by combining T2-weighted imaging (T2WI), T1 mapping, first-pass perfusion, and late gadolinium enhancement (LGE) imaging. CMR-guided catheter ablation offers a unique opportunity to investigate acute ablation lesions. Until present, studies only used T2WI and LGE CMR to assess acute lesions. METHODS AND RESULTS Fifteen patients with CTI-dependent atrial flutter scheduled for CMR-guided RF ablation were prospectively enrolled. Directly after achieving bidirectional block of the CTI line, CMR imaging was performed using: T2WI (n = 15), T1 mapping (n = 10), first-pass perfusion (n = 12), and LGE (n = 12) imaging. In case of acute reconnection, additional RF ablation was performed. In all patients, T2WI demonstrated oedema in the ablation region. Right atrial T1 mapping was feasible and could be analysed with a high inter-observer agreement (r = 0.931, ICC 0.921). The increase in T1 values post-ablation was significantly lower in regions showing acute reconnection compared with regions without reconnection [37 ± 90 ms vs. 115 ± 69 ms (P = 0.014), and 3.9 ± 9.0% vs. 11.1 ± 6.8% (P = 0.022)]. Perfusion defects were present in 12/12 patients. The LGE images demonstrated hyper-enhancement with a central area of hypo-enhancement in 12/12 patients. CONCLUSION Tissue characterization of acute lesions during CMR-guided CTI-dependent atrial flutter ablation demonstrates oedema, perfusion defects, and necrosis with a core of microvascular damage. Right atrial T1 mapping is feasible, and may identify regions of acute reconnection that require additional RF ablation.
Collapse
Affiliation(s)
- G P Bijvoet
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands
- Department of Cardiology, Maastricht University Medical Center, P.Debyelaan 25, PO Box 5800, 6202 AZ Maastricht, The Netherlands
| | - H M J M Nies
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
| | - R J Holtackers
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
| | - B M Martens
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
| | - J Smink
- Department of Clinical Research, Philips Healthcare, Best, The Netherlands
| | - D Linz
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands
- Department of Cardiology, Maastricht University Medical Center, P.Debyelaan 25, PO Box 5800, 6202 AZ Maastricht, The Netherlands
- Faculty of Health and Medical Sciences, Department of Biomedical Sciences, University of Copenhagen, Copenhagen, Denmark
- Department of Cardiology, Radboud University Medical Center, Nijmegen, The Netherlands
| | - K Vernooy
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands
- Department of Cardiology, Maastricht University Medical Center, P.Debyelaan 25, PO Box 5800, 6202 AZ Maastricht, The Netherlands
| | - J E Wildberger
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
| | - R Nijveldt
- Department of Cardiology, Radboud University Medical Center, Nijmegen, The Netherlands
| | - S M Chaldoupi
- Department of Cardiology, Maastricht University Medical Center, P.Debyelaan 25, PO Box 5800, 6202 AZ Maastricht, The Netherlands
| | - C Mihl
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
| |
Collapse
|