1
|
Li D, Wu X, Gao W, Gao J. Multi-mode joint modulation of array wireless power transfer. Sci Rep 2023; 13:15780. [PMID: 37737246 PMCID: PMC10516869 DOI: 10.1038/s41598-023-42983-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Accepted: 09/17/2023] [Indexed: 09/23/2023] Open
Abstract
In this paper, an array multi-transmitter multi-mode wireless power transfer system is proposed. The system realizes the joint modulation of three transmitter coil working modes of single transmitter coil, dual transmittercoil and four transmitter coils in the wireless power transfer system through PI closed-loop control, which can realize the stable output of WPT system in three different transmitter coil work modes. It effectively compensates for the shortcomings of the single working mode of a single transmitter coil and the limited range of effective working areas, and improves the robustness of the wireless power transfer system.
Collapse
Affiliation(s)
- Da Li
- School of Electrical Engineering, Naval University of Engineering, Wuhan, China
| | - Xusheng Wu
- School of Electrical Engineering, Naval University of Engineering, Wuhan, China
| | - Wei Gao
- School of Electrical Engineering, Naval University of Engineering, Wuhan, China
| | - Jianxin Gao
- National Key Laboratory of Electromagnetic Energy, Naval University of Engineering, Wuhan, China.
| |
Collapse
|
2
|
Shi LJ, Wei BX, Xu L, Lin YC, Wang YP, Zhang JC. Magnetoencephalography for epileptic focus localization based on Tucker decomposition with ripple window. CNS Neurosci Ther 2021; 27:820-830. [PMID: 33942534 PMCID: PMC8193700 DOI: 10.1111/cns.13643] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Accepted: 03/24/2021] [Indexed: 11/30/2022] Open
Abstract
AIMS To improve the Magnetoencephalography (MEG) spatial localization precision of focal epileptic. METHODS 306-channel simulated or real clinical MEG is estimated as a lower-dimensional tensor by Tucker decomposition based on Higher-order orthogonal iteration (HOOI) before the inverse problem using linearly constraint minimum variance (LCMV). For simulated MEG data, the proposed method is compared with dynamic imaging of coherent sources (DICS), multiple signal classification (MUSIC), and LCMV. For clinical real MEG of 31 epileptic patients, the ripples (80-250 Hz) were detected to compare the source location precision with spikes using the proposed method or the dipole-fitting method. RESULTS The experimental results showed that the positional accuracy of the proposed method was higher than that of LCMV, DICS, and MUSIC for simulation data. For clinical real MEG data, the positional accuracy of the proposed method was higher than that of dipole-fitting regardless of whether the time window was ripple window or spike window. Also, the positional accuracy of the ripple window was higher than that of the spike window regardless of whether the source location method was the proposed method or the dipole-fitting method. For both shallow and deep sources, the proposed method provided effective performance. CONCLUSION Tucker estimation of MEG for source imaging by ripple window is a promising approach toward the presurgical evaluation of epileptics.
Collapse
Affiliation(s)
- Li-Juan Shi
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China.,Beijing Advanced Innovation Centre for Big Data-Based Precision Medicine, Beihang University, Beijing, China.,Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing, China
| | - Bo-Xuan Wei
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China.,Beijing Advanced Innovation Centre for Big Data-Based Precision Medicine, Beihang University, Beijing, China.,Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing, China.,Hefei Innovation Research Institute, Beihang University, Hefei, Anhui, China
| | - Lu Xu
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China.,Beijing Advanced Innovation Centre for Big Data-Based Precision Medicine, Beihang University, Beijing, China.,Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing, China
| | - Yi-Cong Lin
- Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing, China.,Brain Functional Disease and Neuromodulation of Beijing Key Laboratory, Beijing, China
| | - Yu-Ping Wang
- Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing, China.,Brain Functional Disease and Neuromodulation of Beijing Key Laboratory, Beijing, China
| | - Ji-Cong Zhang
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China.,Beijing Advanced Innovation Centre for Big Data-Based Precision Medicine, Beihang University, Beijing, China.,Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing, China.,Hefei Innovation Research Institute, Beihang University, Hefei, Anhui, China
| |
Collapse
|
3
|
Mirbozorgi SA, Jia Y, Zhang P, Ghovanloo M. Toward a High-Throughput Wireless Smart Arena for Behavioral Experiments on Small Animals. IEEE Trans Biomed Eng 2019; 67:2359-2369. [PMID: 31870973 DOI: 10.1109/tbme.2019.2961297] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
This work presents a high-throughput and scalable wirelessly-powered smart arena for behavioral experiments made of multiple EnerCage Homecage (HC) systems, operating in parallel in a way that they can fit in standard racks that are commonly used in animal facilities. The proposed system, which is referred to as the multi-EnerCage-HC (mEHC), increases the volume of data that can be collected from more animal subjects, while lowering the cost and duration of experiments as well as stress-induced bias by minimizing the involvement of human operators. Thus improving the quality, reproducibility, and statistical power of experiment outcomes, while saving precious lab space. The system is equipped with an auto-tuning mechanism to compensate for the resonance frequency shifts caused by the dynamic nature of the mutual inductance between adjacent homecages. A functional prototype of the mEHC system has been implemented with 7 units and analyzed for theoretical design considerations that would minimize the effects of interference and resonance frequency bifurcation. Experiment results demonstrate robust wireless power and data transmissions capabilities of this system within the noisy lab environment.
Collapse
|
5
|
Analysis and Optimization of Four-Coil Planar Magnetically Coupled Printed Spiral Resonators. SENSORS 2016; 16:s16081219. [PMID: 27527169 PMCID: PMC5017384 DOI: 10.3390/s16081219] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/02/2016] [Revised: 07/21/2016] [Accepted: 07/29/2016] [Indexed: 11/16/2022]
Abstract
High-efficiency power transfer at a long distance can be efficiently established using resonance-based wireless techniques. In contrast to the conventional two-coil-based inductive links, this paper presents a magnetically coupled fully planar four-coil printed spiral resonator-based wireless power-transfer system that compensates the adverse effect of low coupling and improves efficiency by using high quality-factor coils. A conformal architecture is adopted to reduce the transmitter and receiver sizes. Both square architecture and circular architectures are analyzed and optimized to provide maximum efficiency at a certain operating distance. Furthermore, their performance is compared on the basis of the power-transfer efficiency and power delivered to the load. Square resonators can produce higher measured power-transfer efficiency (79.8%) than circular resonators (78.43%) when the distance between the transmitter and receiver coils is 10 mm of air medium at a resonant frequency of 13.56 MHz. On the other hand, circular coils can deliver higher power (443.5 mW) to the load than the square coils (396 mW) under the same medium properties. The performance of the proposed structures is investigated by simulation using a three-layer human-tissue medium and by experimentation.
Collapse
|
6
|
Mirbozorgi SA, Bahrami H, Sawan M, Gosselin B. A Smart Cage With Uniform Wireless Power Distribution in 3D for Enabling Long-Term Experiments With Freely Moving Animals. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2016; 10:424-434. [PMID: 26011866 DOI: 10.1109/tbcas.2015.2414276] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
This paper presents a novel experimental chamber with uniform wireless power distribution in 3D for enabling long-term biomedical experiments with small freely moving animal subjects. The implemented power transmission chamber prototype is based on arrays of parallel resonators and multicoil inductive links, to form a novel and highly efficient wireless power transmission system. The power transmitter unit includes several identical resonators enclosed in a scalable array of overlapping square coils which are connected in parallel to provide uniform power distribution along x and y. Moreover, the proposed chamber uses two arrays of primary resonators, facing each other, and connected in parallel to achieve uniform power distribution along the z axis. Each surface includes 9 overlapped coils connected in parallel and implemented into two layers of FR4 printed circuit board. The chamber features a natural power localization mechanism, which simplifies its implementation and ease its operation by avoiding the need for active detection and control mechanisms. A single power surface based on the proposed approach can provide a power transfer efficiency (PTE) of 69% and a power delivered to the load (PDL) of 120 mW, for a separation distance of 4 cm, whereas the complete chamber prototype provides a uniform PTE of 59% and a PDL of 100 mW in 3D, everywhere inside the chamber with a size of 27×27×16 cm(3).
Collapse
|
7
|
Lee B, Ahn D, Ghovanloo M. Three-Phase Time-Multiplexed Planar Power Transmission to Distributed Implants. IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS 2016; 4:263-272. [PMID: 27034913 PMCID: PMC4809544 DOI: 10.1109/jestpe.2015.2436391] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
A platform has been presented for wireless powering of receivers (Rx's) that are arbitrarily distributed over a large area. A potential application could be powering of small Rx implants, distributed over large areas of the brain. The transmitter (Tx) consists of three overlapping layers of hexagonal planar spiral coils (hex-PSC) that are horizontally shifted to provide the strongest and most homogeneous electromagnetic flux coverage. The three-layer hex-PSC array is driven by a three-phase time-division-multiplexed power Tx that takes the advantage of the carrier phase shift, coil geometries, and Rx time constant to homogeneously power the arbitrarily distributed Rx's regardless of their misalignments. The functionality of the proposed three-phase power transmission concept has been verified in a detailed scaled-up high-frequency structure simulator Advanced Design System simulation model and measurement setup, and compared with a conventional Tx. The new Tx delivers 5.4 mW to each Rx and achieves, on average, 5.8% power transfer efficiency to the Rx at the worst case 90° angular misalignment, compared with 1.4% by the conventional Tx.
Collapse
Affiliation(s)
- Byunghun Lee
- GT-Bionics Laboratory, School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30308 USA
| | - Dukju Ahn
- University of California at San Diego, La Jolla, CA 92093 USA
| | - Maysam Ghovanloo
- GT-Bionics Laboratory, School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30308 USA
| |
Collapse
|
8
|
Ahn D, Kiani M, Ghovanloo M. Enhanced Wireless Power Transmission Using Strong Paramagnetic Response. IEEE TRANSACTIONS ON MAGNETICS 2014; 50:8000308. [PMID: 26120144 PMCID: PMC4479303 DOI: 10.1109/tmag.2013.2284752] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A method of quasi-static magnetic resonant coupling has been presented for improving the power transmission efficiency (PTE) in near-field wireless power transmission, which improves upon the state of the art. The traditional source resonator on the transmitter side is equipped with an additional resonator with a resonance frequency that is tuned substantially higher than the magnetic field excitation frequency. This additional resonator enhances the magnetic dipole moment and the effective permeability of the power transmitter, owing to a phenomenon known as the strong paramagnetic response. Both theoretical calculations and experimental results show increased PTE due to amplification of the effective permeability. In measurements, the PTE was improved from 57.8% to 64.2% at the nominal distance of 15 cm when the effective permeability was 2.6. The power delivered to load was also improved significantly, with the same 10 V excitation voltage, from 0.38 to 5.26 W.
Collapse
Affiliation(s)
- Dukju Ahn
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30308 USA
| | - Mehdi Kiani
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30308 USA
| | - Maysam Ghovanloo
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30308 USA
| |
Collapse
|
9
|
McMenamin P, Kiani M, Manns JR, Ghovanloo M. EnerCage: a smart experimental arena with scalable architecture for behavioral experiments. IEEE Trans Biomed Eng 2013; 61:139-48. [PMID: 23955695 DOI: 10.1109/tbme.2013.2278180] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Wireless power, when coupled with miniaturized implantable electronics, has the potential to provide a solution to several challenges facing neuroscientists during basic and preclinical studies with freely behaving animals. The EnerCage system is one such solution as it allows for uninterrupted electrophysiology experiments over extended periods of time and vast experimental arenas, while eliminating the need for bulky battery payloads or tethering. It has a scalable array of overlapping planar spiral coils (PSCs) and three-axis magnetic sensors for focused wireless power transmission to devices on freely moving subjects. In this paper, we present the first fully functional EnerCage system, in which the number of PSC drivers and magnetic sensors was reduced to one-third of the number used in our previous design via multicoil coupling. The power transfer efficiency (PTE) has been improved to 5.6% at a 120 mm coupling distance and a 48.5 mm lateral misalignment (worst case) between the transmitter (Tx) array and receiver (Rx) coils. The new EnerCage system is equipped with an Ethernet backbone, further supporting its modular/scalable architecture, which, in turn, allows experimental arenas with arbitrary shapes and dimensions. A set of experiments on a freely behaving rat were conducted by continuously delivering 20 mW to the electronics in the animal headstage for more than one hour in a powered 3538 cm(2) experimental area.
Collapse
|
10
|
Jow UM, Kiani M, Huo X, Ghovanloo M. Towards a smart experimental arena for long-term electrophysiology experiments. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2012; 6:414-23. [PMID: 23853228 PMCID: PMC3721429 DOI: 10.1109/tbcas.2012.2211872] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Wireless power and data transmission have created promising prospects in biomedical research by enabling perpetual data acquisition and stimulation systems. We present a work in progress towards such a system, called the EnerCage, equipped with scalable arrays of overlapping planar spiral coils (PSC) and 3-axis magnetic sensors for focused wireless power transmission to randomly moving targets, such as small freely behaving animal subjects. The EnerCage system includes a stationary unit for 3D non-line-of-sight localization and inductive power transmission through a geometrically optimized PSC array. The localization algorithm compares the magnetic sensor outputs with a threshold to activate a PSC. All PSCs are optimized based on the worst-case misalignment, considering parasitics from the overlapping and adjacent PSCs. EnerCage also has a mobile unit attached to or implanted in the subject's body, which includes a permanent magnetic tracer for localization and back telemetry circuit for efficient closed-loop inductive power regulation. The EnerCage system is designed to enable long-term electrophysiology experiments on freely behaving small animal subjects in large experimental arenas without requiring them to carry bulky batteries. A prototype of the EnerCage system with five PSCs and five magnetic sensors achieved power transfer efficiency (PTE) of 19.6% at the worst-case horizontal misalignment of 49.1 mm (√1/3 of the PSC radius) and coupling distance of 78 mm with a mobile unit coil, 20 mm in radius. The closed-loop power management mechanism maintains the mobile unit received power at 20 mW despite misalignments, tilting, and distance variations up to a maximum operating height of 120 mm (PTE = 5%).
Collapse
|