1
|
Li Y, Yang Y, Li W, Chen C, Lin Q, Huang H, Gu Y, Jin X, Qian Z. Fiber optic-based integrated system for in vivo multiscale pharmacokinetic monitoring. BIOMEDICAL OPTICS EXPRESS 2024; 15:3770-3782. [PMID: 38867773 PMCID: PMC11166437 DOI: 10.1364/boe.523179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 04/07/2024] [Accepted: 04/14/2024] [Indexed: 06/14/2024]
Abstract
This paper presents the development of a fiber-optic-based fluorescence detection system for multi-scale monitoring of drug distribution in living animals. The integrated system utilized dual laser sources at the wavelengths of 488 nm and 650 nm and three photomultiplier channels for multi-color fluorescence detection. The emission spectra of fluorescent substances were tracked using the time-resolved fluorescence spectroscopy module to continuously monitor their blood kinetics. The fiber bundle, consisting of 30,000 optic filaments, was designed for wide-field mesoscopic imaging of the drug's interactions within organs. The inclusion of a gradient refractive index (GRIN) lens within the setup enabled fluorescence confocal laser scanning microscopy to visualize the drug distribution at the cellular level. The system performance was verified by imaging hepatic and renal tissues in mice using cadmium telluride quantum dots (CdTe QDs) and R3. By acquiring multi-level images and real-time data, our integrated system underscores its potential as a potent tool for drug assessment, specifically within the realms of pharmacokinetic and pharmacodynamic investigations.
Collapse
Affiliation(s)
- Yiran Li
- Department of Biomedical Engineering, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China
| | - Yamin Yang
- Department of Biomedical Engineering, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China
| | - Weitao Li
- Department of Biomedical Engineering, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China
| | - Chaofan Chen
- Department of Biomedical Engineering, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China
| | - Qiao Lin
- Department of Biomedical Engineering, College of Engineering, China Pharmaceutical University, Nanjing 211198, China
| | - Haipeng Huang
- Department of Biomedical Engineering, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China
| | - Yueqing Gu
- Department of Biomedical Engineering, College of Engineering, China Pharmaceutical University, Nanjing 211198, China
| | - Xiaofei Jin
- Department of Biomedical Engineering, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China
| | - Zhiyu Qian
- Department of Biomedical Engineering, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China
| |
Collapse
|
2
|
Thomas S, George JG, Ferranti F, Bhattacharya S. Metaoptics for aberration correction in microendoscopy. OPTICS EXPRESS 2024; 32:9686-9698. [PMID: 38571197 DOI: 10.1364/oe.514870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Accepted: 01/30/2024] [Indexed: 04/05/2024]
Abstract
Compact and minimally invasive scanning fiber endoscopy probes with micron-level resolution have great potential in detailed tissue interrogation and early disease diagnosis, which are key applications of confocal reflectance imaging at visible wavelengths. State-of-the-art imaging probes commonly employ refractive lens triplets or gradient refractive index (GRIN) lenses as the micro-objective. However, off-axis aberration emerges as a critical factor affecting resolution, especially at the extremities of the imaging field. In response to this challenge, we propose what we believe to be a novel design integrating a metasurface with the GRIN micro-objective to address optical aberrations during beam scan. The metasurface acts as a corrector element for optical aberrations in a fiber-scanning endoscope using the same fiber for excitation and collection. Modeling such hybrid refractive-metasurface designs requires the coupling of simulation techniques across macroscale and nanoscale optics, for which we used an Ansys simulation workflow platform. Operating at a wavelength of 644 nm, this metaoptical element serves as a thin and compact aberration correction surface, ensuring uniform resolution across the entire imaging field. Experimental results from our scanning fiber endoscopy system demonstrate a notable enhancement in optical performance both on-axis and off-axis, achieving a resolution of 3 µm at the center of the imaging field. Impressively, the resolution experiences only a modest degradation by a factor of 0.13 at the edge of the field of view compared to the center.
Collapse
|
3
|
Stark SL, Gross H, Reglinski K, Messerschmidt B, Eggeling C. Field curvature reduction in miniaturized high numerical aperture and large field-of-view objective lenses with sub 1 µm lateral resolution. BIOMEDICAL OPTICS EXPRESS 2023; 14:6190-6205. [PMID: 38420300 PMCID: PMC10898576 DOI: 10.1364/boe.499785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 10/09/2023] [Accepted: 10/10/2023] [Indexed: 03/02/2024]
Abstract
In this paper the development of a miniaturized endoscopic objective lens for various biophotonics applications is presented. While limiting the mechanical dimensions to 2.2 mm diameter and 13 mm total length, a numerical aperture of 0.7 in water and a field-of-view (FOV) diameter of 282 µm are achieved. To enable multimodal usage a wavelength range of 488 nm to 632 nm was considered. The performed broad design study aimed for field curvature reduction when maintaining the sub 1 µm resolution over a large FOV. Moreover, the usage of GRadient-INdex (GRIN) lenses was investigated. The resolution, field curvature improvement and chromatic performance of the novel device were validated by means of a confocal laser-scanning-microscope.
Collapse
Affiliation(s)
| | - Herbert Gross
- Fraunhofer Institute for Applied Optics and Precision Engineering IOF, Albert-Einstein-Str. 7, 07745 Jena, Germany
| | - Katharina Reglinski
- Institute of Applied Optics and Biophysics, Friedrich-Schiller-University Jena, Max-Wien-Platz 4, 07743 Jena, Germany
- Leibniz Institute of Photonic Technology e.V., Albert-Einstein-Str. 9, 07745 Jena, Germany
- University Hospital Jena, Bachstr. 18, 07743 Jena, Germany
| | | | - Christian Eggeling
- Institute of Applied Optics and Biophysics, Friedrich-Schiller-University Jena, Max-Wien-Platz 4, 07743 Jena, Germany
- Leibniz Institute of Photonic Technology e.V., Albert-Einstein-Str. 9, 07745 Jena, Germany
| |
Collapse
|
4
|
Kučikas V, Werner MP, Schmitz-Rode T, Louradour F, van Zandvoort MAMJ. Two-Photon Endoscopy: State of the Art and Perspectives. Mol Imaging Biol 2023; 25:3-17. [PMID: 34779969 PMCID: PMC9971078 DOI: 10.1007/s11307-021-01665-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Revised: 09/15/2021] [Accepted: 10/05/2021] [Indexed: 10/19/2022]
Abstract
In recent years, the demand for non-destructive deep-tissue imaging modalities has led to interest in multiphoton endoscopy. In contrast to bench top systems, multiphoton endoscopy enables subcellular resolution imaging in areas not reachable before. Several groups have recently presented their development towards the goal of producing user friendly plug and play system, which could be used in biological research and, potentially, clinical applications. We first present the technological challenges, prerequisites, and solutions in two-photon endoscopic systems. Secondly, we focus on the applications already found in literature. These applications mostly serve as a quality check of the built system, but do not answer a specific biomedical research question. Therefore, in the last part, we will describe our vision on the enormous potential applicability of adult two-photon endoscopic systems in biological and clinical research. We will thus bring forward the concept that two-photon endoscopy is a sine qua non in bringing this technique to the forefront in clinical applications.
Collapse
Affiliation(s)
- Vytautas Kučikas
- Institute for Molecular Cardiovascular Research (IMCAR), RWTH Aachen University, Aachen, Germany. .,XLIM Research Institute, Limoges University, CNRS, Limoges, France.
| | - Maximilian P Werner
- Department of Biohybrid and Medical Textiles (BioTex), RWTH Aachen University, Aachen, Germany
| | - Thomas Schmitz-Rode
- Department of Biohybrid and Medical Textiles (BioTex), RWTH Aachen University, Aachen, Germany
| | | | - Marc A M J van Zandvoort
- Institute for Molecular Cardiovascular Research (IMCAR), RWTH Aachen University, Aachen, Germany.,Institute for Cardiovascular Diseases CARIM, Department of Molecular Cell Biology, Maastricht University, Maastricht, Netherlands
| |
Collapse
|
5
|
Learned end-to-end high-resolution lensless fiber imaging towards real-time cancer diagnosis. Sci Rep 2022; 12:18846. [PMID: 36344626 PMCID: PMC9640670 DOI: 10.1038/s41598-022-23490-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Accepted: 11/01/2022] [Indexed: 11/09/2022] Open
Abstract
Recent advances in label-free histology promise a new era for real-time diagnosis in neurosurgery. Deep learning using autofluorescence is promising for tumor classification without histochemical staining process. The high image resolution and minimally invasive diagnostics with negligible tissue damage is of great importance. The state of the art is raster scanning endoscopes, but the distal lens optics limits the size. Lensless fiber bundle endoscopy offers both small diameters of a few 100 microns and the suitability as single-use probes, which is beneficial in sterilization. The problem is the inherent honeycomb artifacts of coherent fiber bundles (CFB). For the first time, we demonstrate an end-to-end lensless fiber imaging with exploiting the near-field. The framework includes resolution enhancement and classification networks that use single-shot CFB images to provide both high-resolution imaging and tumor diagnosis. The well-trained resolution enhancement network not only recovers high-resolution features beyond the physical limitations of CFB, but also helps improving tumor recognition rate. Especially for glioblastoma, the resolution enhancement network helps increasing the classification accuracy from 90.8 to 95.6%. The novel technique enables histological real-time imaging with lensless fiber endoscopy and is promising for a quick and minimally invasive intraoperative treatment and cancer diagnosis in neurosurgery.
Collapse
|
6
|
Wang C, Liu H, Cui H, Ma J, Li Y, Tian J, Jin C, Chen Y, Gao Y, Fu Q, Hu Y, Wu D, Yu F, Wu R, Wang A, Feng L. Two-photon endomicroscopy with microsphere-spliced double-cladding antiresonant fiber for resolution enhancement. OPTICS EXPRESS 2022; 30:26090-26101. [PMID: 36236806 DOI: 10.1364/oe.461325] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2022] [Accepted: 06/16/2022] [Indexed: 06/16/2023]
Abstract
We demonstrate a miniature fiber-optic two two-photon endomicroscopy with microsphere-spliced double-cladding antiresonant fiber for resolution enhancement. An easy-to-operate process for fixing microsphere permanently in an antiresonant fiber core, by arc discharge, is proposed. The flexible fiber-optic probe is integrated with a parameter of 5.8 mm × 49.1 mm (outer diameter × rigid length); the field of view is 210 µm, the resolution is 1.3 µm, and the frame rate is 0.7 fps. The imaging ability is verified using ex-vivo mouse kidney, heart, stomach, tail tendon, and in-vivo brain neural imaging.
Collapse
|
7
|
Guan H, Liang W, Li A, Gau YTA, Chen D, Li MJ, Bergles DE, Li X. Multicolor fiber-optic two-photon endomicroscopy for brain imaging. OPTICS LETTERS 2021; 46:1093-1096. [PMID: 33649665 PMCID: PMC11214692 DOI: 10.1364/ol.412760] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Accepted: 01/26/2021] [Indexed: 06/12/2023]
Abstract
Visualizing activity patterns of distinct cell types during complex behaviors is essential to understand complex neural networks. It remains challenging to excite multiple fluorophores simultaneously so that different types of neurons can be imaged. In this Letter, we report a multicolor fiber-optic two-photon endomicroscopy platform in which two pulses from a Ti:sapphire laser and an optical parametric oscillator were synchronized and delivered through a single customized double-clad fiber to excite multiple chromophores. A third virtual wavelength could also be generated by spatial-temporal overlapping of the two pulses. The performance of the fiber-optic multicolor two-photon endomicroscope was demonstrated by in vivo imaging of a mouse cerebral cortex with "Brainbow" labeling.
Collapse
Affiliation(s)
- Honghua Guan
- Department of Electrical and Computer Engineering, Johns Hopkins University, Maryland 21218, USA
| | - Wenxuan Liang
- Department of Biomedical Engineering, Johns Hopkins University, Maryland 21205, USA
| | - Ang Li
- Department of Biomedical Engineering, Johns Hopkins University, Maryland 21205, USA
| | - Yung-Tian A. Gau
- Department of Neuroscience, Johns Hopkins University, Maryland 21205, USA
| | - Defu Chen
- Department of Biomedical Engineering, Johns Hopkins University, Maryland 21205, USA
| | - Ming-Jun Li
- Science and Technology Division, Corning Incorporated, Corning, New York 14831, USA
| | - Dwight E. Bergles
- Department of Neuroscience, Johns Hopkins University, Maryland 21205, USA
| | - Xingde Li
- Department of Electrical and Computer Engineering, Johns Hopkins University, Maryland 21218, USA
- Department of Biomedical Engineering, Johns Hopkins University, Maryland 21205, USA
| |
Collapse
|
8
|
Kaur M, Lane PM, Menon C. Scanning and Actuation Techniques for Cantilever-Based Fiber Optic Endoscopic Scanners-A Review. SENSORS 2021; 21:s21010251. [PMID: 33401728 PMCID: PMC7795415 DOI: 10.3390/s21010251] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 12/30/2020] [Accepted: 12/30/2020] [Indexed: 01/20/2023]
Abstract
Endoscopes are used routinely in modern medicine for in-vivo imaging of luminal organs. Technical advances in the micro-electro-mechanical system (MEMS) and optical fields have enabled the further miniaturization of endoscopes, resulting in the ability to image previously inaccessible small-caliber luminal organs, enabling the early detection of lesions and other abnormalities in these tissues. The development of scanning fiber endoscopes supports the fabrication of small cantilever-based imaging devices without compromising the image resolution. The size of an endoscope is highly dependent on the actuation and scanning method used to illuminate the target image area. Different actuation methods used in the design of small-sized cantilever-based endoscopes are reviewed in this paper along with their working principles, advantages and disadvantages, generated scanning patterns, and applications.
Collapse
Affiliation(s)
- Mandeep Kaur
- MENRVA Research Group, Schools of Mechatronic Systems Engineering and Engineering Science, Simon Fraser University, Surrey, B.C. V3T 0A3, Canada;
- School of Engineering Science, Simon Fraser University, Burnaby, B.C. V5A 1S6, Canada;
- Imaging Unit, Integrative Oncology, BC Cancer Research Center, Vancouver, B.C., V5Z 1L3, Canada
| | - Pierre M. Lane
- School of Engineering Science, Simon Fraser University, Burnaby, B.C. V5A 1S6, Canada;
- Imaging Unit, Integrative Oncology, BC Cancer Research Center, Vancouver, B.C., V5Z 1L3, Canada
| | - Carlo Menon
- MENRVA Research Group, Schools of Mechatronic Systems Engineering and Engineering Science, Simon Fraser University, Surrey, B.C. V3T 0A3, Canada;
- School of Engineering Science, Simon Fraser University, Burnaby, B.C. V5A 1S6, Canada;
- Correspondence:
| |
Collapse
|